South Fork WT Plant Tour5/1/2007
South Fork WT Plant Tour5/1/2007
![Page 2: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/2.jpg)
Water Source: Water Source: The Clackamas RiverThe Clackamas River
![Page 3: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/3.jpg)
Tour Guide Mark CageTour Guide Mark CageSouth Fork WT PlantSouth Fork WT Plant
15962 S Hunter Ave. Oregon City,15962 S Hunter Ave. Oregon City, Oregon 97045, Oregon 97045, (503) 657-5030 (503) 657-5030
![Page 4: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/4.jpg)
The Control Room:Where all Plant data is recorded
The Control Room:Where all Plant data is recorded
![Page 5: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/5.jpg)
SCADASCADASupervisory Control And Data Supervisory Control And Data AcquisitionAcquisition
![Page 6: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/6.jpg)
SCADA Stats:SCADA Stats:
• Plant during tour is running at 10.3 Plant during tour is running at 10.3 MGDMGD
• Plant runs at approximately 6 MGD in Plant runs at approximately 6 MGD in Winter, 18 MGD in SummerWinter, 18 MGD in Summer
• Current Alum dosage at 4.5 parts in Current Alum dosage at 4.5 parts in the Rapid Mix the Rapid Mix
• Pre-feed Polymer #LT7990 dosage Pre-feed Polymer #LT7990 dosage at .8 partsat .8 parts
• Plant during tour is running at 10.3 Plant during tour is running at 10.3 MGDMGD
• Plant runs at approximately 6 MGD in Plant runs at approximately 6 MGD in Winter, 18 MGD in SummerWinter, 18 MGD in Summer
• Current Alum dosage at 4.5 parts in Current Alum dosage at 4.5 parts in the Rapid Mix the Rapid Mix
• Pre-feed Polymer #LT7990 dosage Pre-feed Polymer #LT7990 dosage at .8 partsat .8 parts
![Page 7: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/7.jpg)
Pilot Filters:Pilot Filters:Conveniently located in the Control Conveniently located in the Control
RoomRoom
Pilot Filters:Pilot Filters:Conveniently located in the Control Conveniently located in the Control
RoomRoom
Dual media filtersDual media filters4’ Anthracite coal4’ Anthracite coal 1’ Garnet sand1’ Garnet sand
![Page 8: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/8.jpg)
Pilot Filters:Pilot Filters:
• Miniature replicas of the main filtersMiniature replicas of the main filters
• Sampled daily Sampled daily
• Help avoid plant shut down Help avoid plant shut down
• Save about ½ hour per day on the work Save about ½ hour per day on the work loadload
![Page 9: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/9.jpg)
Stream Current MonitorStream Current Monitor
Stream Current MonitorStream Current Monitor
Optimizes coagulant dosage Optimizes coagulant dosage
![Page 10: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/10.jpg)
Chlorine Spikes or “Slugs”Chlorine Spikes or “Slugs”
• Plant start-up causes 5 minute Plant start-up causes 5 minute chlorine spikechlorine spike
• Spike goes down as plant comes on-Spike goes down as plant comes on-lineline
![Page 11: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/11.jpg)
Rapid Mix Injection Order:
•Polymer•Alum•Pre-Chlorination with Sodium
Hypochlorite•Flash Mixed by use of pump turbulence,
(no mechanical mixing takes place)
Factoid:One pound Liquid Alum equals 5.3 LBS of
dry Alum
•Polymer•Alum•Pre-Chlorination with Sodium
Hypochlorite•Flash Mixed by use of pump turbulence,
(no mechanical mixing takes place)
Factoid:One pound Liquid Alum equals 5.3 LBS of
dry Alum
![Page 12: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/12.jpg)
Polymer DeliveryPolymer Delivery
Pretreatment
•#LT7990 dosage at .8 parts#LT7990 dosage at .8 parts
![Page 13: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/13.jpg)
•Current Current Alum Alum dosage at dosage at 4.5 parts in 4.5 parts in the Rapid the Rapid MixMix
Pretreatment
Alum PumpsAlum Pumps
![Page 14: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/14.jpg)
Alum TankAlum TankCorrosive Material Corrosive Material Post welded measurementsPost welded measurements
Pretreatment
![Page 15: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/15.jpg)
Pretreatment: Sodium Pretreatment: Sodium HypochloriteHypochlorite
Chlorine Pre-feed at 0.7 Chlorine Residual at 1.0Chlorine Pre-feed at 0.7 Chlorine Residual at 1.0
![Page 16: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/16.jpg)
Pretreatment
Rapid Mix wellRapid Mix well
AlumAlum
ChlorineChlorine
Alum, Polymer and Sodium hypochloriteeAlum, Polymer and Sodium hypochloritee
PolymerPolymer
![Page 17: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/17.jpg)
Flocculation Chamber with Flocculation Chamber with Serpentine BafflesSerpentine Baffles
![Page 18: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/18.jpg)
Sedimentation/Contact Sedimentation/Contact BasinBasin
![Page 19: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/19.jpg)
$100 Plastic Tube used to prevent $100 Plastic Tube used to prevent wave vibration caused buy pumpingwave vibration caused buy pumping – Savings: $100,000 in repairs! – Savings: $100,000 in repairs!
![Page 20: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/20.jpg)
Dual Media Filter:Dual Media Filter:
•4’ Anthracite Coal4’ Anthracite Coal - - 1’ Garnet 1’ Garnet SandSand. . •Backwash after approximately Backwash after approximately 70hrs depending on turbidity. 70hrs depending on turbidity. •Filter Aid Polymer is used.Filter Aid Polymer is used.•Flow approximately 2000 GPM Flow approximately 2000 GPM during tour.during tour.
![Page 21: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/21.jpg)
View of Pipe gallery While Standing View of Pipe gallery While Standing over Clear Well (.55 Million Gallons)over Clear Well (.55 Million Gallons)
![Page 22: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/22.jpg)
Sodium Hypochlorite Generation:Sodium Hypochlorite Generation:Injection of salt water reacts with 700 amps of Injection of salt water reacts with 700 amps of electricity and titanium plates. Produces 600 electricity and titanium plates. Produces 600 lbs 0.8% NaOCllbs 0.8% NaOCl per day (300 lbs per cell).per day (300 lbs per cell).
Disinfection:Disinfection:
![Page 23: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/23.jpg)
Sodium Hypochlorite Generation:Sodium Hypochlorite Generation:Injection of salt water reacts with 700 amps of Injection of salt water reacts with 700 amps of electricity and titanium plates. Produces 300 electricity and titanium plates. Produces 300 lbs 0.8% NaOCllbs 0.8% NaOCl per day.per day.
Two cells= 600 lbsTwo cells= 600 lbs
On-site Generation of On-site Generation of Disinfectants (OSG)Disinfectants (OSG)
![Page 24: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/24.jpg)
On-site Generation of On-site Generation of Disinfectants (OSG)Disinfectants (OSG)
Hydrogen bubblesHydrogen bubblesAnodeAnode
CathodeCathode
2Cl- >> Cl2 + 2e-2Cl- >> Cl2 + 2e- 2H2O + 2e->>H2 + 2OH-2H2O + 2e->>H2 + 2OH-
NaCl + H2O >>>NaOCl + H2NaCl + H2O >>>NaOCl + H2
HOCl + OH->>H2O +OCl-HOCl + OH->>H2O +OCl-
cellWater Softener
Brine tank
![Page 25: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/25.jpg)
On-site Generation of On-site Generation of Disinfectants (OSG)Disinfectants (OSG)Advantages:Advantages:
Operator safety: Operator safety: No toxic No toxic chlorine gas handling, safety and chlorine gas handling, safety and regulationregulationGreener solutionGreener solution: No chemical : No chemical shipments (all you need is pure shipments (all you need is pure NaCl)NaCl)Minimal storageMinimal storage
Advantages:Advantages:Operator safety: Operator safety: No toxic No toxic chlorine gas handling, safety and chlorine gas handling, safety and regulationregulationGreener solutionGreener solution: No chemical : No chemical shipments (all you need is pure shipments (all you need is pure NaCl)NaCl)Minimal storageMinimal storage
![Page 26: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/26.jpg)
On-site Generation of On-site Generation of Disinfectants (OSG)Disinfectants (OSG)
Disadvantages:Disadvantages:Hydrogen gas generation: Hydrogen gas generation: Toxic, Toxic, colorless, flammable (vent) colorless, flammable (vent) regulationregulationNeed steady water composition Need steady water composition and have to soften waterand have to soften waterCell maintenanceCell maintenance: Need to wash : Need to wash with muriatic acid (HCl)with muriatic acid (HCl)
Disadvantages:Disadvantages:Hydrogen gas generation: Hydrogen gas generation: Toxic, Toxic, colorless, flammable (vent) colorless, flammable (vent) regulationregulationNeed steady water composition Need steady water composition and have to soften waterand have to soften waterCell maintenanceCell maintenance: Need to wash : Need to wash with muriatic acid (HCl)with muriatic acid (HCl)
![Page 27: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/27.jpg)
Chlorine MetersChlorine Meters
![Page 28: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/28.jpg)
Chlorine Stats:
•Chlorine Pre-feed at 0.7
•Chlorine Residual at 1.0
•Chlorine Pre-feed at 0.7
•Chlorine Residual at 1.0
![Page 29: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/29.jpg)
High Turbidity:
• The technique used at South Fork for dealing with extremely high turbidity is to use both Polymer and Alum in increased dosages.
![Page 30: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/30.jpg)
Soda Ash DeliverySoda Ash Delivery
•Dry hopper Dry hopper •Lead and Copper RuleLead and Copper Rule
![Page 31: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/31.jpg)
Soda Ash mixerSoda Ash mixer
![Page 32: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/32.jpg)
Soda Ash in bags used for pH Soda Ash in bags used for pH adjustmentadjustment
![Page 33: South Fork WT Plant Tour 5/1/2007 South Fork WT Plant Tour 5/1/2007](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d365503460f94a0ddca/html5/thumbnails/33.jpg)
EndEnd