soumi chillers - systèmes de réfrigération co2
TRANSCRIPT
PHE1
ET1
P1
OPTION
CHILLER
PHE2
P2
ET2
OPTION OPTION
1
HEAT RECLAIM
GAS COOLER
Set Pressure 1740 psig
RV
GENERAL INFORMATION
Customer: Project name:
Contact person: Email:
Site address:
Phone #:
PHE1Chiller
Capacity:
Details:
ELECTRICAL INFORMATION
Site available power : 575V / 3ph 460V / 3ph 230V / 3ph
INTEGRATED (Transfo.)
Maximum current limitation : N/A YES - MAX Amps: ___________
INSTALLATION INFORMATION
Space limitations - Chiller: YES NO
Space limitations - Gas cooler: YES NO
If yes, provide
GAS COOLER INFORMATION
STANDARD LOW NOISEECM
Noise level limit: DB at meters
Gas cooler mounting location : GROUND ROOF
Location of the unit :
ADDITIONNAL INFORMATION
OPTIONS
Start-up parts :
Energy measurement :
Additional warranty :
Factory mounted disconnect :
CO2 detectors :
YES NO
COMPLETE - number of years :_________ COMPRESSORS ONLY - number of years : ____________
Data Logger and monitoring : YES NO
YES NO YES NO
YES NO
Power for control circuit : 120V / 1ph INDEPENDENT FEED
Piping : Carbon steel Stainless steel Gas cooler coil: Copper Stainless st
BASEMENT GROUND FLOOR UPSTAIRS
Chiller casing finish :
Floating evaporation pressure : YES NO
YES NO
"Low noise" construction : YES NO Required sound level :
High pressure gauges and hoses for filling:
If yes, provide
Other site limitations : YES NO If yes, provide
Details:
Fan type:
PAINTED BLUE PAINTED GRAY
Copper
DB at meters
PROCESS
T° Inlet: T° Outlet: GPM:
Pressure drop:
PHE2Heat reclaim
Model:
GPM:T° Outlet:T° Inlet:Capacity:
Double wallPressure drop: Model:
Pumps
P1
P2
Fluid:
Motor: Model:
Fluid: Double wall
VFD
Motor: Model: VFDHead:
Head:
STAINLESS STEEL
BACK UP
BACK UP
00
N/A
R01DProject Info - Compact Chillers
Tommy Dolbec, ing.
Manon Trudel
COMPACT
12.5-50 T.R.CHILLERS
DHW
SYSTEMGLYCOLHEATING
PROCESS
CO2 LIQUID RECEIVER
CO2
COMPRESSORS
HeatRecovery
Units
Gas Cooler
HEATEXCHANGER
HEATEXCHANGER
HEAT EXCHANGERCO2 / BRINE OR GLYCOL
GENERAL INFORMATION
Customer: Project name:
Contact person: Email:
Site address:
Phone #:
PHE1Chiller
Capacity:
Details:
ELECTRICAL INFORMATION
Site available power : 575V / 3ph 460V / 3ph 230V / 3ph 208V / 3ph
INTEGRATED (Transfo.)
Maximum current limitation : N/A YES - MAX Amps: ___________
INSTALLATION INFORMATION
Space limitations - Chiller: YES NO
Space limitations - Gas cooler: YES NO
If yes, provide dwg or sketch
GAS COOLER INFORMATION
STANDARD LOW NOISEECM
Noise level limit: DB at meters
Mounting location : GROUND ROOF
Location of the Chiller :
ADDITIONNAL INFORMATION
OPTIONS
Start-up parts :
Energy measurement :
Additional warranty :
CO2 detectors :
YES NO
COMPLETE - number of years :_________ COMPRESSORS ONLY - number of years : ____________
Data Logger and monitoring : YES NO
YES NO
YES NO
Power for control circuit : 120V / 1ph INDEPENDENT FEED
Piping : Carbon steel Stainless steel Gas cooler coil: Copper Stainless steel
MECHANICAL ROOM
Floating evaporation pressure : YES NO
If yes, provide dwg or sketch
Other site limitations : YES NO If yes, provide dwg or sketch
Details:
Fan type:
CAREL
Copper
PROCESS
T° Inlet: T° Outlet: GPM: T
Pressure drop:
PHE2Heat reclaim
Model:
GPM: TT° Outlet:T° Inlet:Capacity:
Double wallPressure drop: Model:
Pumps
P1
P2
Fluid:
Motor: Model:
Fluid: Double wall
VFD
Motor: Model: VFDHead:
Head:
DANFOSS
OUTDOOR
Controls : MICROTHERMO OTHER
HEAT RECLAIM-DIRECT CO2
Description
COIL ONLY FAN AND COIL
Capacity Air flow Max Air Pressure drop Entering Air Temp Duct dimensions#
COIL ONLY FAN AND COIL
COIL ONLY FAN AND COIL
COIL ONLY FAN AND COIL
BACK UP PUMP
BACK UP PUMP
Fins : STANDARD EPOXY COATING
00
N/A
R01DProject Info - Large Chillers
CARNOTREFRIGERATION
Tommy Dolbec, ing.
Manon Trudel
CHILLERS30 TR and over