sor building 2008 section c - concretor

Upload: syafikaaffandi

Post on 05-Apr-2018

222 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/31/2019 SOR BUILDING 2008 Section C - Concretor

    1/4

    C CONCRETOR

    Item Description Unit Rate (RM)

    No.

    1 Lean concrete (Grade 15) in 50mm thick blinding. M 12.50

    2 Mass Concrete (Grade 20) in non structural works such as pavements,

    upstands, kerbs and the like. M3

    260.00

    3 Reinforced concrete (Grade 25) in sub-structural works such as pile caps, pad

    footings, column stumps, and the like. M3

    280.00

    4 Reinforced concrete (Grade 30) in sub-structural works such as pile caps, pad

    footings, column stumps, and the like. M3

    300.00

    5 Reinforced concrete (Grade 40) in sub-structural works such as pile caps, pad

    footings, column stumps, and the like. M3

    340.00

    6 Reinforced concrete (Grade 25) in sub-structural works such as ground beams,

    ground slab, apron slabs, steps, platform slabs, ramp and the like. M3

    290.00

    7 Reinforced concrete (Grade 30) in sub-structural works such as ground beams,

    ground slab, apron slabs, steps, platform slabs, ramp and the like. M3

    310.00

    8 Reinforced concrete (Grade 40) in sub-structural works such as ground beams,

    ground slab, apron slabs, steps, platform slabs, ramp and the like. M3

    350.00

    9 Reinforced concrete (Grade 25) in super-structural works such as columns,

    stiffeners, walls, and the like. M3

    290.00

    10 Reinforced concrete (Grade 30) in super-structural works such as columns,

    stiffeners, walls, and the like. M3 310.00

    11 Reinforced concrete (Grade 40) in super-structural works such as columns,

    stiffeners, walls, and the like. M3

    350.00

    12 Reinforced concrete (Grade 25) in super-structural works such as suspended

    floor beams, suspended floor slabs, roof beams, roof slabs, gutter, canopy

    slabs, staircases, landing slab, and the like. M3

    295.00

    13 Reinforced concrete (Grade 30) in super-structural works such as suspended

    floor beams, suspended floor slabs, roof beams, roof slabs, gutter, canopy

    slabs, staircases, landing slab, and the like. M3

    315.00

    14 Reinforced concrete (Grade 40) in super-structural works such as suspended

    floor beams, suspended floor slabs, roof beams, roof slabs, gutter, canopy

    slabs, staircases, landing slab, and the like. M3

    355.00

    15 Mass Concrete (Grade 20) in civil works such as fencing post footings, thrust

    blocks, scour stops, road kerb bedding, and the like. M3

    260.00

    16 Reinforced concrete (Grade 25) in road pavement slabs, cross-over slabs, and

    the like. M3

    280.00

    17 Reinforced concrete (Grade 25) in sewerage works such as septic tanks,

    manholes, and the like. M3

    300.00

    SOR BUILDING 2008/Page 9 of 41

  • 7/31/2019 SOR BUILDING 2008 Section C - Concretor

    2/4

    C CONCRETOR... (CONT'D)

    Item Description Unit Rate (RM)

    No.

    18 Mild steel bars in reinforcement to concrete work generally including all cutting,

    bending and placing in position:

    a) 6 mm Diameter. KG 3.00

    b) 10mm Diameter. KG 3.00

    c) 12mm Diameter. KG 3.00

    d) 16mm - 32mm Diameter. KG 2.90

    e) above 32mm Diameter. KG 2.90

    19 High tensile steel bars in reinforcement to concrete work, generally including all

    cutting, bending and placing in position:

    a) 10mm Diameter. KG 3.00

    b) 12mm Diameter. KG 3.00

    c) 16mm - 32mm Diameter. KG 2.90

    20 Welded steel fabric reinforcement of 100mm x 200mm weighing 3.73 kg/ms and

    embedded in concrete (MS-B283/ B6). M2

    20.90

    21 Welded steel fabric reinforcement of 100mm x 200mm mesh weighing 4.53

    kg/ms ditto(MS-B385/B7). M2

    25.40

    22 Welded steel fabric reinforcement of 100mm x 200mm mesh weighing 5.93

    kg/m2 ditto (MS-B503/B8). M2

    33.20

    23 Welded steel fabric reinforcement of 100mm x 200mm mesh weighing 6.97

    kg/m2 ditto (MS-B636/B9). M2

    39.00

    24 Welded steel fabric reinforcement of 200mm x 200mm mesh weighing 2.22

    kg/ms ditto(MS-A142/A6). M2

    12.50

    25 Welded steel fabric reinforcement of 200mm x 200mm mesh weighing 3.02

    kg/ms ditto(MS-A193/A7). M2

    17.00

    26 Welded steel fabric reinforcement of 200mm x 200mm mesh weighing 3.95kg/m2 ditto (MS - A252/A8). M

    222.50

    27 Welded steel fabric reinforcement of 200mm x 200mm mesh weighing 4.99

    kg/m2 ditto (MS-A318/A9). M2

    28.00

    28 Welded steel fabric reinforcement of 200mm x 200mm mesh weighing 6.16

    kg/ms ditto(MS-A393/A10). M2

    35.00

    29 Expanded metal reinforcement of 100mm x 400mm weighing 2.61kg/ms (MS-

    C283/ C6). M2

    14.60

    30 Expanded metal reinforcement of weighing 4.34 kg/ms (MS-C503/ C8). M 24.30

    SOR BUILDING 2008/Page 10 of 41

  • 7/31/2019 SOR BUILDING 2008 Section C - Concretor

    3/4

    C CONCRETOR... (CONT'D)

    Item Description Unit Rate (RM)

    No.

    31 Mild steel fabric mesh reinforcement :

    a) BRC 65. M2

    8.80

    b) BRC 66. M2

    7.40

    c) BRC 610. M2

    5.20

    Sawn Formwork As Specified

    32 To sides of foundation and ground beam. M2

    32.00

    33 To sides of wal l. M2

    32.00

    34 To sides of column, staircase, lintols etc. M2 33.00

    35 To sides and soffit of beam. M2

    33.00

    36 To soffit of suspended floor slab, roof slab, landing slab etc. M2

    35.00

    37 Extra over last four items for sloping surfaces. M2

    2.50

    38 Extra over formwork for curved on plan and elevation to varying radius. M2

    5.00

    39 Extra over for strutting to soffits of slab/ beams exceeding 3.60m high for every

    600mm stages. M2

    4.00

    40 Extra over sawn formwork for wrot surfaces. M2

    6.00

    41 Extra over sawn formwork for patterned formwork with fillets at 150mm centres

    or in 150mm wide "V" jointed timber boards. M2

    15.00

    42 12mm Bitumen impregnated fibreboard 150mm wide as expansion joint filler in

    reinforced concrete structure including filling 10mm x 10mm recess with non

    shrinkable mastic grouting. M 28.00

    Precast Concrete Work

    43 150 mm Wide internal precast reinforced concrete (Grade 25) half roundsurface water drain channel including bends, junctions etc. finished fair on

    exposed surfaces and bedding as specified, including all necessary excavations

    and part backfill. M 22.00

    44 225 mm Wide internal precast reinforced concrete (Grade 25) half round

    surface water drain channel including bends, junctions etc. finished fair on

    exposed surfaces and bedding as specified, including all necessary excavations

    and part backfill. M 33.00

    45 300 mm Wide internal precast reinforced concrete (Grade 25) half round

    surface water drain channel including bends, junctions etc. finished fair on

    exposed surfaces and bedding as specified, including all necessary excavations

    and part backfill. M 36.00

    SOR BUILDING 2008/Page 11 of 41

  • 7/31/2019 SOR BUILDING 2008 Section C - Concretor

    4/4

    C CONCRETOR... (CONT'D)

    Item Description Unit Rate (RM)

    No.

    46 375 mm Wide internal precast reinforced concrete (Grade 25) half round

    surface water drain channel including bends, junctions etc. finished fair onexposed surfaces and bedding as specified, including all necessary excavations

    and part backfill. M 45.00

    47 450mm x 450mm x 75mm Thick precast reinforced concrete (Grade 25)

    'longkang pencegah malaria' finished fair on exposed surfaces and bedding as

    specified including all necessary excavation. M 112.00

    48 50mm Thick precast reinforced concrete (Grade 25) drain cover with and

    including one layer of fabric reinforcement, weighing 2.35kg/m2 (A6). M2

    35.00

    49 112mm x 150mm Precast concrete (Grade 25) l intol including formwork but

    excluding reinforcement. M 17.00

    DAMP PROOF MEMBRANE

    50 `Pabkote No.3' or other approved bituminous damp proof membrane applied on

    concrete surfaces al l to the approval of the S.O and in accordance with the

    manufacturer's instruction. M2

    5.00

    51 Bitumen based expansion joints for concrete pavement. M 10.00

    SOR BUILDING 2008/Page 12 of 41