sonobat quickstart: basic operations
DESCRIPTION
SonoBat QuickStart: basic operations. Alternative: Drag and drop a file or directory here. open file. help info. SonoBat works best with individual files of bat pass events. . notes embedded with wav file. compressed view removes pauses between calls. - PowerPoint PPT PresentationTRANSCRIPT
SonoBat QuickStart: basic operations
open file Alternative:Drag and drop a file or directory here
help info
SonoBat works best with individual files of bat pass events.
notes embedded with wav file
compressed view removes pauses between calls
same file displayed in real time view displays entire recording
select file with one
click
drag to scroll
click to jump
pull down to navigate up
directory hierarchy
previous file highlighted
play sound
moving cursor tracks playback
playback of time expanded files in real time for audible soundssimulates a bat detector for ultrasound to hear actual call cadence
Contextual Help- Cntl-H (Windows); Cmd-Shift-H (Mac)
popup help messages
zoom selection selectable to only zoom time scale(eliminates need to capture freq to maintain scale of view)
Individual calls may be processed into high resolution standard views. This enables viewing calls in standard time scales that facilitate comparison and recognition without further manual zooming and resetting scales.
In compressed view mode, calls may be selected for processing into std views by just selecting any area near the call.
press to have std view time automatically selected
buttons for manual std view time selection
In real time mode, std view selections and centering may be selected manually.
initiate std view
Initial coarse zoom
final centering
zoom, then invoke std
view
Std view selections may be saved to the reference library with attached notes.
appended reference view
Any std view saved as a reference view may be used for subsequent comparison to sequences and std views.
Reference views may be assembled into compilations.
appended compiled reference view of different calls to show a species repertoire at a glance
ruler enabled to show a frequency line for comparison
low frequency noise may be filtered
filter applied
SonoBat can automatically select a filter, or accept a manual selection New with version 2.9,
Careful: leaving manual filters enabled can miss low freq signals
correct filter to render audible frequency bat calls
Quantitative analysis of calls in std view mode with automated call trending.
More than fifty quantitative parameters written to a spreadsheet.
Intelligent call trending algorithm can recognize the end of calls buried in echo and noise.
SonoBat can also successfully establish trends through noise and from low power signals.
Files may be edited in real time
mode to crop noise or other
undesirable sections.
Filenames may be edited from within SonoBat.File notes and attributes
may be edited.
default panel size
stretchedpanel size
The SonoBat panel may be stretched to fit any screen size.
The SonoBat preferences panel enables customization and automation of many default settings.