solutions for hand, wrist, and elbow repair and...
TRANSCRIPT
Solutions for Hand, Wrist, and Elbow Repair and Reconstruction
Solutions for Hand, Wrist, and Elbow Repair and Reconstruction
Cayenne Medical is a trademark of Cayenne Medical, Inc. ©Copyright 2015 Cayenne Medical, Inc. All rights reserved.
Cayenne Medical Inc. 16597 North 92nd St, Suite 101 | Scottsdale, AZ 85260cayennemedical.com | 1-888-229-3661
Providing all the pieces to solve your most challenging procedural puzzles.
Elbow
Hand
Lateral epicondylitis repairUlnar or radial collateral ligament reconstructionBiceps tendon reattachment
Wrist
Scapholunate ligament reconstruction
Volar plate reconstruction
Ulnar or lateral collateral ligament reconstructionTendon transfers in phalanx
Repair or reconstruction of collateral ligamentsFlexor and extensor tendon at the PIP, DIP, and MCP joints for all digits
Collateral ligament repair
16597 North 92nd St, Suite 101 | Scottsdale, AZ 85260 | These products are covered by one or more U.S. patents pending.
online at cayennemedical.com | 1-888-229-3661 Contact Cayenne Medical for order information
Quattro® Link Knotless Anchors
Quattro® Link 4.5mmQuattro® Link 2.9mm
Quattro® GL/GL2 2.9mm
SureLock™ All-Suture Anchors
Quattro® Bolt Tenodesis Screw Tendon Loading into Snare of Quattro® Bolt Inserter
2
Quattro® Bolt Tenodesis Screws
Quattro® GL/GL2 Suture Anchors419NQuattro® GL2
(Cayenne Medical)
JuggerKnot 1.4(Biomet)
BioRaptor 2.3 PK(Smith & Nephew)
PEEK Suture Tak(Arthrex)
Gryphon BR P(Depuy Mitek)
100 200 300 400
Biomechanical Pullout StrengthPre-Loaded Glenoid Labrum Anchors
Glenoid anchor mean load to failure (N)
Conclusions:The Cayenne Medical Inc. Quattro® GL2 suture anchor performed very favorably, satisfying desirable time-zero mechanical characteristics. Further direct comparative testing will be performed. Note that comparative data is for reference only, and does not indicate that direct mechanical testing was performed in this test.
References:1. Barber FA, Herbert MA, Beavis RC, Barrera-Oro F. Suture anchor materials, eyelets, and designs: Update 2008. Arthroscopy 2008;24:859-867.2. Barber FA, Herbert MA, Hapa O, Rapley JH, Barber CA, Bynum JA, Hrnack SA. Biomechanical analysis of pullout strengths of rotator cuff and glenoid anchors: 2011 update. Arthroscopy. 2011 Jul;27(7):895-905.
Competitor devices may include trademarked and or registered properties.
3
· Technology designed to maintain consistent tension· Ability to individually tension suture strands to surgeon preference
· Consistent inserter-controlled deployment · Strength comparable to standard implants with minimized bone loss · Available in 2.2mm double loaded, 1.4mm single loaded, and short 1.4mm single loaded
· Tendon-in-socket fixation· Smooth tip screw design preserves tendon integrity· Available in 5mm, 6mm, 7mm, 8mm, and 9mm
· Bio-inert PEEK-OPTIMA® Material · Available with 1 or 2 pre-loaded suture limbs
1 70330A- Biomechanical Pullout Strength Of Quattro® X and Quattro® Link Rotator Cuff Anchors
70828- Rev A
2 80218A - Biomechanical Pullout Strength & Cyclic Testing of The SureLock™ All-Suture Anchors
3 70331A – Biomechanical Pullout Strength of Quattro® GL Glenoid Labrum Repair Anchors
Short SureLock™ 1.4mmSingle Loaded, Size 2-0 or 0 Suture with 3/8, 17mm Tapered Needles
1