NSSG SUPPORT SOLUTIONS This document contains information that was exported directly from Konica's NSSG Support knowledge base. Some solutions may contain hyperlink references which originally contained links to graphic or text files. If you wish to view these files, you must access the solutions via NSSG Web Support on Konica's website, www.konicabt.com. Legal Notice This document is designed as a diagnostic tool, primarily for Konica's support personnel, and authorized service representatives. Konica recommends that all service be performed by an authorized service representative. Users are responsible for seeking advice of a Konica authorized service representative regarding the information, opinion, advice or content of this document. USER AGREES THAT USE OF THIS DOCUMENT IS AT USER'S SOLE RISK AND THAT THIS DOCUMENT IS PROVIDED ON AN AS IS BASIS WITHOUT WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, WARRANTIES OF TITLE OR IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OTHER THAN THOSE WARRANTIES THAT ARE IMPLIED BY LAW AND INCAPABLE OF EXCLUSION. IN NO EVENT WILL KONICA OR THOSE ACTING ON ITS BEHALF BE LIABLE FOR ANY DAMAGES, INCLUDING, WITHOUT LIMITATION, DIRECT, INDIRECT, INCIDENTAL, SPECIAL, CONSEQUENTIAL OR PUNITIVE DAMAGES ARISING OUT OF YOUR USE OF THIS DOCUMENT. Copyright 2003, Konica Business Technologies U.S.A., Inc. May 2003 IP-602 - ALL ACTIVE SOLUTIONS

Upload: hugo-luis-escalante

Post on 27-Oct-2014

144 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Solution Guide Controller IP-602 Konica 7085

NSSG SUPPORT SOLUTIONS

This document contains information that was exported directly from Konica's NSSG Supportknowledge base. Some solutions may contain hyperlink references which originallycontained links to graphic or text files. If you wish to view these files, you must access thesolutions via NSSG Web Support on Konica's website, www.konicabt.com.

Legal Notice

This document is designed as a diagnostic tool, primarily for Konica's supportpersonnel, and authorized service representatives. Konica recommends thatall service be performed by an authorized service representative. Users areresponsible for seeking advice of a Konica authorized service representativeregarding the information, opinion, advice or content of this document.

USER AGREES THAT USE OF THIS DOCUMENT IS AT USER'S SOLE RISKAND THAT THIS DOCUMENT IS PROVIDED ON AN AS IS BASIS WITHOUTWARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING,BUT NOT LIMITED TO, WARRANTIES OF TITLE OR IMPLIED WARRANTIES OFMERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OTHERTHAN THOSE WARRANTIES THAT ARE IMPLIED BY LAW AND INCAPABLEOF EXCLUSION. IN NO EVENT WILL KONICA OR THOSE ACTING ON ITSBEHALF BE LIABLE FOR ANY DAMAGES, INCLUDING, WITHOUTLIMITATION, DIRECT, INDIRECT, INCIDENTAL, SPECIAL, CONSEQUENTIALOR PUNITIVE DAMAGES ARISING OUT OF YOUR USE OF THIS DOCUMENT.

Copyright 2003, Konica Business Technologies U.S.A., Inc.

May 2003IP-602 - ALL ACTIVE SOLUTIONS

Page 2: Solution Guide Controller IP-602 Konica 7085

IP-602

KN306, how to reset to factory defaults.DESCRIPTION: SOLUTION ID: 132,138

SOLUTION: To reset the KN306 card to factory settings, perform the following:1. Power down the IP unit and remove the cover.2. Remove the KN306 from the IP unit.3. Set jumper OP2 to pins 1 and 2 (left and middle) for factory initialization.4. Reseat the card in the IP unit.5. Power the IP unit ON and leave it on for five minutes.6. Power down the IP unit and remove the KN306 card.7. Reset jumper OP2 to pins 2 and 3 (left and middle).8. Reseat the card into the IP unit and reassemble the cover.9. The card should now be initialized and should print a status page once both the IP unit and theprinter have come to a ready state.

USAGE: 6

Unable to load disk 9 of the 5.70 system code.DESCRIPTION: SOLUTION ID: 131,695

SOLUTION: CAUSE: An irregularity with system software in which the IP602 hard drive is not properlyformatted to accept a rewrite of system software.

SOLUTION: Install the latest version of IP602 system software version 5.7.1. This version ofsystem software will fully install properly with all 9 disks. Notes:1. This new version of system software is now available on the NSSG FTP site:[[FTP site| URL ftp://kbtdigital:[email protected]/]] under Black_white_products ->IP_units->System_Software ->IP602. The 5.7.1 file name is 13tbfw571.exe.2. In addition, please download the modification notice (M20020329A1E.zip) associated with thissystem software upgrade. It provides all information regarding the changes and problems correctedwith this upgrade.3. This new version of system software requires additional upgrades to the 7085, KN306, etc...,please pay close attention to - Latest Program Combinations - listed on page 16 of the modificationnotice. All the additional upgrades are also available on the NSSG FTP site.

USAGE: 4

Memory specifications, IP602.DESCRIPTION: SOLUTION ID: 130,274

SOLUTION: The maximum memory capacity, for the IP602, is 256MB.To achieve this capacity, install two MU-402 memory modules (128MB) into memory slot 1 and 2 ofthe IP-602 motherboard.Notes:1. Slots 3 and 4 of the IP-602 motherboard cannot be used, the IP-602 will not initialize if memoryis installed into these slots.2. If installing a MU-402 (128MB) memory module along with a MU-401 (64MB), place the largermodule into slot 1.3. Supported memory modules are:PCUA ITEM DIMM 950631 MU-401 64MB 950632 MU-402 128MB4. All specifications are subject to change.

USAGE: 4

FIREWIRE STACK INIT FAILURE error message during power up with a monitor attached tothe IP602.

DESCRIPTION: SOLUTION ID: 129,489

SOLUTION: CAUSE: The IEEE 1394 board assembly has failed.

SOLUTION: To verify the IEEE 1394 board assembly has failed, perform the following:1. Power OFF the IP602. 2. Remove the IEEE 1394 copier interface cable . 3. Reseat the IEEE 1394 in different PCI slot. 4. Power on IP602 without the IEEE 1394 copier interface cable plugged in.5. If the error reappears, replace the IEEE 1394 board assembly (p/n 13SA-9050).

USAGE: 3

Does the KP utility support tandem printing within an HPUX environment?DESCRIPTION: SOLUTION ID: 147,122

SOLUTION: The KP utility will support tandem printing in an HPUX environment. The latest version of the KPutility and IP602 PPD is required. These are available for download from [[Konica SEC| URLhttp://sec.konicabt.com/main.html]]. Click on [Start], [Products], [KP], then [Download KP] toaccess the downloadable files.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 2

LPR printing is slow or hangs with Microsoft* Windows NT 4.0. Delays or failures may resultwhen you print to a Windows NT 4.0 print server connected through line printer remote

DESCRIPTION: SOLUTION ID: 144,865

2Copyright 2003, Konica Business Technologies U.S.A., Inc. May 2003

Page 3: Solution Guide Controller IP-602 Konica 7085

IP-602

(LPR) to a shared printer using the Line Printer Daemon (LPD) service.CAUTION: This solution contains information about editing the registry. Before editing theregistry, understand how to restore it if a problem occurs. For information about how to dothis, view the [["Restoring the Registry"| URLhttp://techweb.konicabt.com/tpm/media/restore_registry.pdf]] Help topic in Regedit.exe orthe [["Restoring a Registry Key"| URLhttp://techweb.konicabt.com/tpm/media/restore_regkey.pdf]] Help topic in Regedt32.exe.

SOLUTION: Note: This procedure works for Windows 2000 as well.

CAUSE: With Windows NT 4.0 Service Pack 3 and later, the default TCP Ports for LPR are721-731. The symptom only occurs if 11 or more jobs are simultaneously spooled in an NTspooler. Once the 11th job reaches the spooler, all jobs will pause for approximately 3 minutesbetween jobs. Changes can be made so that ports greater than 1,023 can be used to prevent LPRfrom running out of available ports or conflicting with reserved ports. There is a registry entries thatallow line printer remote (LPR) to use any available port higher than 1,023. With this entry, LPR isno longer restricted to only using the 11 TCP Ports (721 through 731) and will not conflict withreserved ports, even on very busy print servers.

SOLUTION: In Service Pack 3 (or later), a new registry entry is automatically generated when anew LPR port is created. This setting is defined on a per printer port basis and defaults to 0, whichis RFC compliant. To enable individual IP address ports to use TCP ports 1024 and higher, applyService Pack 3 (or later) and then perform the following steps:1. Start Registry Editor (Regedt32.exe) and go to the following key: HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\LPDSVC\lpr WARNING: Using Registry Editor incorrectly can cause serious problems that may requirereinstallaton of the operating system. Konica or Microsoft cannot guarantee that problems resultingfrom the incorrect use of Registry Editor can be solved. Use Registry Editor at your own risk.Notes: a. For information about how to edit the registry, view the [["Change Keys And Values"| URLhttp://techweb.konicabt.com/tpm/media/Change_keys.pdf ]] Help topic in Registry Editor(Regedit.exe) or the [["Add and Delete Information in the Registry" | URLhttp://techweb.konicabt.com/tpm/media/add_delete_info.pdf]] and [["Edit Registry Information"| URLhttp://techweb.konicabt.com/tpm/media/edit_reg_info.pdf]] Help topics in Regedt32.exe. b. Back up the registry before editing it and update your Emergency Repair Disk (ERD).2. The [[installed LPR ports will be displayed on the right of the window| IMAGEV:\bitmaps\cjc143.bmp SCROLL]]. On the far right there will be a data value of (0) or (1) inparenthesis. The data value of (0) indicates that this LPR port uses ports 721-731, which is thedefault. The data value of (1) indicates that this LPR port uses any port greater than (>) 1024. 3. To change a LPR port to use a port greater than 1024, perform the following: a. Double-click the entry to view the Edit DWORD Value window. b.. Change the value data from 0 to 1, and then click OK. c. Repeat steps a and b as required to change other LPR ports. d. Close the Registry Editor window. e. Restart the Spooler Service for the changes to take affect. Type the following command at acommand prompt: net stop spooler f. To restart the Spooler service, type the following command at a command prompt: net start spooler4. For more detailed and updated information see [[Microsoft Knowledge Base Article - 179156 |URL http://techweb.konicabt.com/tpm/media/lprlpdprinting.pdf]].Note: The reference links are live in the document.5. To view any PDF, Acrobat* Reader must be installed. Acrobat Reader can be downloaded forfree from the Adobe* Web site at: [[http://www.adobe.com/products/acrobat/readstep2.html| URLhttp://www.adobe.com/products/acrobat/readstep2.html]]

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 2

Common PCL* and PJL printer commands for the IP602 controller.DESCRIPTION: SOLUTION ID: 135,586

SOLUTION: For developers or users that would like to create their own drivers or manually insert printercommands, for common PCL [[Top Ten Most Commonly Requested PCL Commands| IMAGEV:\bitmaps\cjc176.bmp SCROLL]] list.The following are all of the PJL commands that control finishing functionality for the 7085 with anIP602:@PJL SET RESOLUTION=400 (600)@PJL SET COPIES=#@PJL SET ORIENTATION=PORTRAIT (LANDSCAPE)@PJL SET PAPERTRAY=AUTO (TRAY1, TRAY2, TRAY3, TRAY4, MANUAL)@PJL SET PAPER=LETTER (LEGAL, TABLOID)@PJL SET PIFRONT=OFF (PITRAY1)@PJL SET PIBACK=OFF (PITRAY1)@PJL SET OUTPUTBIN=DEFAULT (BIN1, BIN2)

USAGE: 2

3Copyright 2003, Konica Business Technologies U.S.A., Inc. May 2003

Page 4: Solution Guide Controller IP-602 Konica 7085

IP-602

@PJL SET COLLATE=ON (OFF)@PJL SET DUPLEX=ON (OFF)@PJL SET BINDING=LONGEDGE (SHORTEDGE)@PJL SET JOBOFFSET=ON (OFF)@PJL SET STAPLEPOSITION=OFF (LEFT, TOP2, LEFT2)@PJL SET LAYOUT=OFF (4IN1, 2IN1, 2IN1RPT)@PJL SET PUNCH=TOP (LEFT)@PJL SET FOLD=OFF (ON)@PJL SET TRIM=OFF (ON)@PJL SET STITCH=OFF (ON)@PJL SET FRONTCOVER=OFF (ON)@PJL SET FRONTPRINT=OFF (ON)@PJL SET FRONTTRAY=MANUAL (TRAY1, TRAY2, TRAY3, TRAY4, SHEETFEEDER)@PJL SET BACKCOVER=OFF (ON)@PJL SET BACKPRINT=OFF (ON)@PJL SET BACKTRAY=MANUAL (TRAY1, TRAY2, TRAY3, TRAY4)@PJL SET WAIT=OFF (ON, PROOF)@PJL SET IMAGESHIFT=OFF (ON)Notes:1. These codes are case sensitive.2. The information in parentheses is the additional options that are available which each PJLcommand.3. Certain combinations of commands, such as double staple side and tabloid size paper, are notpossible given the physical limits of the machine. If selecting some of these "illegal" combinations,the unit will either drop one of the selections or indicate an error condition. A complete [[DriverFunction Combination List | URLhttp://techweb.konicabt.com/tpm/media/IP602_Users_Guide-2.pdf]] can be found in the IP602User's Guide.4. The commands listed above are Konica-specific.5. A listing of common universal PCL commands can be found in the [[HP* Technical ReferenceManual| URL http://techweb.konicabt.com/tpm/media/HP_Ref.pdf]]. The IP601 conforms to HPPCL 5E standards.6. If additional PJL commands are required, please contact NSSG.7. To view the above links, Acrobat* Reader must be installed. Acrobat Reader can bedownloaded for free from the Adobe* Web site at:[[http://www.adobe.com/products/acrobat/readstep2.html| URLhttp://www.adobe.com/products/acrobat/readstep2.html]]

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

How to obtain the verification key for the demo version of Scantrip for the Macintosh*version 2.0.

DESCRIPTION: SOLUTION ID: 133,336

SOLUTION: The Scantrip for the Macintosh application will not run without an unlock code. Start Scantrip forthe Macintosh for the first time and the program registration screen is displayed. Write down thelock code and go to the [[Konica SEC website| URL http://www.sec.konicabt.com/main.html]]. Clickon the REGISTER button and provide the requested information and the lock code. The unlockcode will be E-mailed. Enter the unlock code and Scantrip for the Macintosh will start.Note: The license is per machine and not transferable.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 2

Latest version of system software.DESCRIPTION: SOLUTION ID: 133,071

SOLUTION: The latest version of system software is now available on the NSSG [[FTP site| URLftp://kbtdigital:[email protected]/Black_white_products/IP_units/System_Software/IP602/13tbfw571.exe]]Note: In addition, please download the [[modification notice| URLftp://kbtdigital:[email protected]/Black_White_products/IP_units/System_Software/IP602/M20020329A1E.zip]] associated with this system software upgrade. It provides all the informationregarding the changes and problems corrected with this upgrade.CAUTION: This new version of system software requires additional upgrades to the 7085, KN306,etc. Please pay close attention to the Latest Program Combinations listed on page 16 of themodification notice. All the additional upgrades are also available on the NSSG FTP site.

USAGE: 2

KN306, the status page will not print out. The internal test print menu cannot be accessedvia the LCD screen and the printer icon displays 'Initial.'

DESCRIPTION: SOLUTION ID: 128,257

SOLUTION: CAUSE: The motherboard BIOS is corrupt. If a monitor is attached it will display the following:When the VxWorks* gets to 'dpo: dpoInit started' the controller will reboot. It may reboot threetimes and hang at 'DPO: Waiting for QUERY_PRN from Nic.' If the KN306 card is removed thecontroller will complete the boot process and the internal test prints can be successfully printed.

USAGE: 2

4Copyright 2003, Konica Business Technologies U.S.A., Inc. May 2003

Page 5: Solution Guide Controller IP-602 Konica 7085

IP-602

SOLUTION: Load the Fail-Safe defaults via the CMOS Setup Utility. To do so, perform thefollowing:1. Connect a monitor and keyboard to the controller.2. Power up the controller, while it is performing the POST press the DEL (delete) key to accessthe CMOS Setup Utility.3. Use the arrow keys to highlight 'Load Fail-Safe Defaults' and press enter.4. Press the y key for Yes and press enter.5. Use the arrow keys to highlight 'Save & Exit Setup' and press enter.6. Press the y key for Yes and press enter.7. With the KN306 installed, verify that the controller completes the boot process and status pageprints out.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

When printing using the PCL* driver, missing text or incomplete documents occur.DESCRIPTION: SOLUTION ID: 125,921

SOLUTION: CAUSE: LPR byte counting is disabled.

SOLUTION: To enable byte counting in the PCL driver, perform the following:1. Enter into the properties of the PCL driver.2. Select the Ports tab.3. Select Configure Port.4. Check the LPR Byte Counting Enabled.Note: This option is available only when the LPR protocol is selected.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 2

How to enable the mainbody mixplex and tab printing functionality.DESCRIPTION: SOLUTION ID: 148,213

SOLUTION: To enable mixplex and tab printing ensure that:1. The Mainbody minimum firmware versions are: Control Ver.14 Op Panel Ver.20 Image-Ver.20 2. The IP-602 must be at system code version Ver.5.7.0 or later.3. The 25 mode Dipswitch 28-0 must be set to 1.Note: The listed firmware versions are minimum versions. Please visit the [[Konica FTP site| URLftp://kbtdigital:[email protected]]] for the most up-to-date version information.

USAGE: 1

How to capture a file when using system code 6.1.0 or higher.DESCRIPTION: SOLUTION ID: 147,620

SOLUTION: To capture a print file on the IP602, perform the following:1. Select the Scan/Server mode and then select Scan-to-Network. Finally select HDD and scan asingle page of anything into Box No. (xxxx). (This will create a subdirectory called (xxxx) in the/ata2/scan subdirectory of the IP602 HDD).Note: The Box No. can be any 4-digit number between 0001 through 9998, although it isrecommended to use the model number of the print engine (7085) for ease of folder location.2. Power down the system with the main power switch in the left rear of the copier.3. Ensure that a monitor and keyboard are installed on the IP602 and reboot the unit.4. If printing through either the KN302a or a third party print server (i.e., i-data*, HP JetDirect*,etc.), at the prompt type DeleteFiles=0 and press ENTER. THIS IS CASE SENSITIVE. At this pointall jobs which are printed will have a print file saved a spool directory.5. For the following commands all characters should be typed in exactly as shown includingquotation marks and slashes. When done printing, press ENTER to obtain a VxWorks prompt.Then type cd "/ata2/spool/" and press ENTER.6. Type ll to obtain a listing of the contents of this spool directory, Note: Complete steps 9a-9d only if the main body is a FORCE 85 otherwise proceed to step 10.************************************************************************************************************ a. Type cd "/ata2/scan" and press ENTER. b. Type mkdir "xxxx" and press ENTER. The xxxx is the number of the mailbox that will be usedto retrieve the file with either FTP or Scantrip. c. Type cd "/ata2/spool/" and press ENTER. d. Type ll and press ENTER to obtain the listing of the contents of the spool directory.************************************************************************************************************7. Now copy all of the desired files from the spool directory to the scan directory. To do this, typecp "filename", "/ata2/scan/xxxx/filename" (a comma and space must be inserted after "filemname")and press ENTER. (xxxx is the Box No. from step 1 or 9b). Of course, replace filename with theactual name of the file to be captured. ************************************************************************************************************If Scantrip is not available, please proceed to step 12. ************************************************************************************************************

USAGE: 1

5Copyright 2003, Konica Business Technologies U.S.A., Inc. May 2003

Page 6: Solution Guide Controller IP-602 Konica 7085

IP-602

8. Now use Scantrip on any workstation on the network to download the spooled print files fromthe xxxx mailbox that was created in step 1 or 9b. The file has now been captured.Note: Retrieving files from an IP602 mail box via Scantrip etc...can only be performed via theKN302a.9. Open up a DOS command prompt from any Windows workstation or laptop.10. At the C:\ type ftp <ip-address> of the printer and press ENTER.11. When prompted, type scan as the user name.12. When prompted, enter the mailbox number that was created in either step1 or step 9b. as thepassword.13. At the ftp> prompt type dir and ENTER to list the contents of the directory.14. At the ftp> type get <filename> and press ENTER. The file will now be downloaded to thecurrent directory of the workstation or laptop from which the initial the FTP command was issued.The file has now been captured.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

When printing an Adobe* Acrobat* document containing graphics via the PostScript* driver,the document prints very slow and only one page at a time.

DESCRIPTION: SOLUTION ID: 145,838

SOLUTION: CAUSE: The Pass-through setting is not selected on the print driver. If the graphics contained inthe document are EPS (Encapsulated PostScript), the driver settings can be set to Pass-throughand the driver will not act on (render) the existing PostScript information. This will speed upprocessing time when printing these types of documents.

SOLUTION: Select the Pass-through setting in the driver in the advanced tab under PostScriptsettings.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 1

Unable to initialize the IP602 after the installation of the KN306. Waiting for query_PRN NICwill display on the monitor.

DESCRIPTION: SOLUTION ID: 145,570

SOLUTION: CAUSE: KN306 is not being recognized.

SOLUTION: Reinstall the KN306 in another PCI SLOT (third slot from the bottom isrecommended). If moving the KN306 to the various slots does not resolve the issue, enter theBIOS settings of the IP602 and load Fail Safe Default settings.

USAGE: 1

How to create a device printer on an AS/400* system using the stock Konica KN or NIC printserver.

DESCRIPTION: SOLUTION ID: 144,134

SOLUTION: The following models will support installation as a device printer using the OS/400 SNMP setupwith the imbedded NIC or KNxxx print server:IP422IP423IP432IP511IP602These models support a setup that will allow a device printer to be created on the AS/400. Whenprinting SCS, this setup can be used with the stock controller NIC cards. This setup supports pagerange control but does not support specific tray calls. In order to support tray call the AS/400workstation customization table (if there is one) must be modified.To load an SNMP driver compatible with the Konica IP unit, perform the following:1. From the Main Menu under Selection or Command, type: crtdevprt <enter>2. Change the following to set up the printer (those settings not changed, keep at default): a. Device Description - (name the printer i.e. Konica) b. Device Class - *LAN c. Device Type - 3812 d. Device Model - 1 e. LAN Attach - *IP f. Port number 10001 (IP432 = 9100) note: use the port number that prints out on the NICstatus page. g. Font Identifier - 011 h. Form Feed - * Autocut i. Manufacturer - *HP5si j. Paper Source (both) - *letter k. Address - (IP address of the NIC) l. System Driver (hit F4) - *IBMSNMPDRV m. Host Transform - ONNote: Vary ON the device to allow attachment.

USAGE: 1

6Copyright 2003, Konica Business Technologies U.S.A., Inc. May 2003

Page 7: Solution Guide Controller IP-602 Konica 7085

IP-602

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

How to set-up Scan to E-mail using Novell* GroupWise*.DESCRIPTION: SOLUTION ID: 143,965

SOLUTION: Novell GroupWise E-mail servers will not accept unvalidated transactions from any source. Post office security has two settings - low (the default) and high. It is recommended to set thesecurity to high for a variety or reasons. If an account has no password and the post office securityis set to low, any user, whether authenticated or not, will be able to access the account by simplysupplying the user name.At this time, GroupWise even at low security settings requires a user name and cannot be usedwith the IP602, IP511, IP422, IP432, IP423, IP431 or IP421.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 1

How to copy a print to file to the printer on Windows* XP Pro or Windows 2000.DESCRIPTION: SOLUTION ID: 142,720

SOLUTION: Share the printer from the workstation or server where it is installed:From a command prompt, the following syntax will allow the file to be directly copied to the printer. c:\>copy/b c:\filename.txt \\workstation-name\share-name

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 1

When printing documents using Microsoft* Word or other application in Windows XP withthe PCL* driver, the document may have random issues with italics and fonts.

DESCRIPTION: SOLUTION ID: 141,966

SOLUTION: SOLUTION: Setting the TrueType option within the print driver to either Bitmap or Raster resolvesthe issue with the text printing a font which resembles the italic format. The recommended settingto print TrueType fonts is Bitmap: Note: TrueType options:This setting controls the way TrueType fonts are stored and printed on the printer. In most casesthis setting can be left on Bitmap. This will cause the printer driver to select the best data format touse for TrueType fonts, and will usually result in the highest quality output and fastest printingspeed.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 1

Unable to install the latest IP-P2P utility. The ip-p2p.dll file cannot be removed or updated.DESCRIPTION: SOLUTION ID: 141,797

SOLUTION: CAUSE: The ip-p2p.dll file is set as read only and it is being used by spool32 in Microsoft*Windows. Therefore, its attributes cannot be changed to 'archive' from Windows.

SOLUTION: The file, ip-p2p.dll, must be deleted. In order to do this, boot to DOS (F8 at powerON, or restart in DOS at power OFF) and change (CD command) to the 'C:\windows\system'directory by typing 'attrib -r ip-p2p.dll'. This will change the file attributes from read only to archive.The file can now be deleted by typing 'del ip-p2p.dll' from the DOS promt or reboot the machineand delete ip-p2p.dll from the c:\windows\system directory. The latest IP-P2P utility can now beloaded.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 1

ERROR IN GETTING NODE FROM EUI message on a monitor prior to the completion ofwarm-up.

DESCRIPTION: SOLUTION ID: 141,713

SOLUTION: CAUSE: The printer relay board/2 has failed (engine component).

SOLUTION: Confirm the printer relay wiring is secured into the socket of the printer relay board 2.Replace printer relay board 2 (p/n 13JQ-7330) as necessary.

USAGE: 1

Is page numbering available from the PCL* or PostScript* print driver?DESCRIPTION: SOLUTION ID: 141,619

SOLUTION: Page numbering from within the print driver is not an option from either the PCL or PostScriptdriver.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 1

The IP602 does not automatically power ON when the main power switch of the 7085 printengine is powered ON.

DESCRIPTION: SOLUTION ID: 140,066

SOLUTION: CAUSE: Power Management CMOS settings for the IP602 are set incorrectly.

SOLUTION: To set the proper Power Management CMOS settings to allow the IP602 to

USAGE: 1

7Copyright 2003, Konica Business Technologies U.S.A., Inc. May 2003

Page 8: Solution Guide Controller IP-602 Konica 7085

IP-602

automatically power ON when the main power switch of the 7085 print engine is powered ON,perform the following:NOTE: Keyboard and monitor attached to the IP602 are required.1. Power ON the IP602.2. With the attached keyboard, press the DELETE key when the monitor displays the IP's initialPOST up screen. This will bring up the CMOS SETUP UTILITY screen.3. With the DOWN arrow key, scroll down to POWER MANAGEMENT SETUP and press ENTER.This will bring up the POWER MANAGEMENT SETUP UTILITY screen.4. The following three settings must be set to allow the IP to power up automatically with the enginemain switch:Note: The UP/DOWN arrow keys will allow navigation to each setting and the PAGE UP/PAGEDOWN keys will allow the settings to be changed. a. Setting, APCI SUSPEND TYPE, must be set to S1 (POWERON SUSPEND). b. Setting, SOFTOFF BY PWR-BTTN, must be set to INSTANT OFF. c. Setting, AC BACK FUNCTION, must be set to FULL-ON.5. After these three settings have been programmed, press F10 and ensure Y is selected in theSAVE TO CMOS AND EXIT window, and then press ENTER. The IP will then rebootautomatically.6. After the IP has fully rebooted, power OFF/ON the print engine main power switch to confirm theIP powers up automatically.

The time and date indicated on a PC via the Scan to E-Mail feature is incorrect.DESCRIPTION: SOLUTION ID: 135,594

SOLUTION: CAUSE: The time and date are not set correctly on the Mail server.

SOLUTION: The time and date information is not contained or generated by the 7085/IP602 Scanto E-mail feature and, therefore, can not be the cause of the incorrect time and date problem. Setthe proper time and date on the mail server.

USAGE: 1

The selection for LPR port does not show up when trying to set up a printer port underMicrosoft* Windows NT.

DESCRIPTION: SOLUTION ID: 134,835

SOLUTION: CAUSE: Incorrect configuration.

SOLUTION: Microsoft TCP/IP* Printing Services needs to be enabled from the Windows NTnetwork setup window.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 1

Can soft fonts be downloaded and stored as resident fonts on the IP602?DESCRIPTION: SOLUTION ID: 133,646

SOLUTION: The ability to store soft fonts on the IP controller is still under development and is not available atthe current time.

USAGE: 1

How to retrieve scanned images from a Macintosh* system.DESCRIPTION: SOLUTION ID: 133,369

SOLUTION: Scantrip for the Macintosh is available on the [[Konica SEC website| URLhttp://www.sec.konicabt.com/main.html]]. Requirements include:1. Power PC CPU.2. Mac OS 8.5 through 9.2.1 and Mac OSX (in Classic Mode only).3. 8 MB RAM (16MB recommended).4. 5 MB of hard disk storage space available.5. Web browser that supports HTML 3.2 or higher.6. Network connection to a Konica printer with scan-to-file functionality.7. Internet connection to register Scantrip for the Macintosh.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 1

GENERAL PROTECTION FAULT ERROR message on the attached monitor when thecontroller is powered ON.

DESCRIPTION: SOLUTION ID: 126,912

SOLUTION: CAUSE: The hard drive file allocation table (FAT) has become corrupted.

SOLUTION: To repartition and reformat the hard drive, perform the following:1. Create a Microsoft* Windows 9x boot disk.2. Power ON the IP controller with the boot disk in the floppy drive.3. At the DOS prompt, type FDISK and press ENTER.4. The first screen that appears asks, "Do you wish to enable large disk support?" Select NO andpress ENTER.5. Select [Delete Partition] or [Logical Drive] and press ENTER.6. Select [Delete Primary DOS Partition], press ENTER, then follow the prompts.

USAGE: 1

8Copyright 2003, Konica Business Technologies U.S.A., Inc. May 2003

Page 9: Solution Guide Controller IP-602 Konica 7085

IP-602

7. When prompted to restart, cycle the power on the IP unit.8. The first screen that appears asks, "Do you wish to enable large disk support." Select NO andpress ENTER.9. Select [Create DOS Partition] or [Logical DOS drive] and press ENTER.10. Select [Create Primary DOS Partition] and press ENTER.11. "Do you want to create the largest partition possible", is asked. Select YES. 12. When prompted to restart, remove the boot disk and cycle the power on the IP unit.13. Reload system software.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

After the i-data* box has been powered OFF/ON, it does not reconnect to the AS/400* viaTN5250E.

DESCRIPTION: SOLUTION ID: 142,021

SOLUTION: CAUSE: The i-data device was not varied offline which allows the TN5250E protocol to connect tothe AS/400.

SOLUTION: Vary the i-data device offline to allow the TN5250E protocol to connect to the AS/400.The Netstat command can also be used to determine if the AS/400 'thinks' that the i-data box is stillconnected. Locate the TCP/IP* address of the box in the Connection Status screen, and end theconnection. Recycle the i-data box and it should connect.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 1

What is the recommended spool setting when printing in a Macintosh* environment?DESCRIPTION: SOLUTION ID: 125,906

SOLUTION: When printing in a Macintosh environment it is recommended that the spool setting is turned OFF.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 1

What does the Job Time Out setting on the LCD panel control?DESCRIPTION: SOLUTION ID: 124,070

SOLUTION: The IP Job Time Out setting on the LCD panel controls data streams printing via the parallel portonly. The IP waits for data sent from an upstream device and sends an end of job to the mainbody, finishes internal processes, and waits for the next data stream.

USAGE: 1

What is the hexadecimal value for a printer reset <ESCE> PCL* command for job control?DESCRIPTION: SOLUTION ID: 123,975

SOLUTION: The hexadecimal value for a printer reset <ESCE> PCL command for job control is 0x04.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 1

What print drivers are compatible with Macintosh* OS X (Version 10)?DESCRIPTION: SOLUTION ID: 127,223

SOLUTION: Konica does not currently have native Macintosh OS X print drivers. Printing from Macintosh OS9x applications within OS X is supported using the current [[Adobe* PostScript* drivers forMacintosh| URLhttp://www.adobe.com/support/downloads/product.jsp?product=44&platform=Macintosh]].

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 1

What scan modes and file types are supported?DESCRIPTION: SOLUTION ID: 148,118

SOLUTION: Scan to Hard Drive, Scan to FTP, and Scan to E-mail support both TIFF and PDF* formats.Note: Scanning to the hard drive in PDF format requires 25 mode dipswitch 25-0 be set to 1. Alsothe main body ROMS must be at least versions I40-1/P19.

USAGE: 0

Unable to remove the IP-P2P (peer-to-peer) utility on a Microsoft* Windows XP workstation.DESCRIPTION: SOLUTION ID: 148,062

SOLUTION: CAUSE: The IP-P2P Utility is not compatible with Windows XP or Windows 2000. The UNIX* printservices that are included as a part of Windows XP and Windows 2000 can be used as analternative to the IP-P2P Utility.

SOLUTION: In the case of Windows XP, the P2P program will not install correctly, therefore itcannot be uninstalled. In order to remove the utility, instances of P2P must be manually removedfrom the registry of the PC.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]].

USAGE: 0

LinkCom* Xpress, test pages will not print out even though the parallel port settings areDESCRIPTION: SOLUTION ID: 147,853

9Copyright 2003, Konica Business Technologies U.S.A., Inc. May 2003

Page 10: Solution Guide Controller IP-602 Konica 7085

IP-602

correct.SOLUTION: CAUSE: The parallel cable is connected to the wrong port on the controller.

SOLUTION: Connect the parallel cable to the 'black' connector on the controller (the one that ishorizontal). The 'pink' connector (the one that is vertical) is not used.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

LinkCom* Xpress test pages will not print out.DESCRIPTION: SOLUTION ID: 147,851

SOLUTION: CAUSE: The parallel port settings are incorrect.

SOLUTION: This solution assumes that the version of the PrintGuide utility is a minimumS42.065.190, using older versions the specified settings may not be accessible. It may benecessary to connect to the device via a browser to view all the necessary settings. Ensure thatthe parallel port settings are correct, to do so, perform the following:1. Connect to the device via PrintGuide by double clicking the detected device in the upper pane.2. Double click any of the logical printers for 'Printer 1.'3. Click on the 'Output Driver' tab.4. Verify that the radio button for 'Centronics Mode' is enabled.5. Verify that the 'Parallel Port Speed' is set for 'Standard.'6. Verify that the 'Use Bi-directional Communication' and 'Request Plug & Play String' check boxesare not checked.7. Click on the 'OK' button.8. Below the menu options via PrintGuide click on the icon with the wrench and down arrow forsave configuration.9. Verify that 'Restart Printserver after download' is checked and click on the 'OK' button.10. Once the device has restarted press the test button and confirm that the test pages print out.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

Microsoft* Windows 2000 Server spooler file crashes when creating a printer on theMacintosh* and pointing the driver through the existing queue on the Windows server.

DESCRIPTION: SOLUTION ID: 147,455

SOLUTION: CAUSE: The PostScript* driver on the server is the Visual-style (DLL-based) driver which is notcompatible with the Macintosh PPD-based PostScript driver.

SOLUTION: This is a Microsoft issue due to be corrected in the next service pack release.Note: As a workaround, load a second PostScript driver on the Windows 2000 server using theadd printer wizard and the version 1.1.6 PPD file. When creating the printer on the Macintosh,point to the PPD-style driver on the Windows server (not the Visual-style driver).

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

KN306, how to disable web access to the card.DESCRIPTION: SOLUTION ID: 147,340

SOLUTION: To disable web access to the KN306, perform the following:1. Enter the following URL: 'http://KN306 TCP/IP* address/nic/port' in a web browser. 2. Enter 0 for the HTTP TCP Port. 3. Enter sysadm for the password. 4. Click on 'Accept Settings' button. 'Port Configuration has been successfully updated' messageshould be displayed after few seconds. 5. Remove 'nic/port' from the URL. 6. Click on 'Network Setup' button. 7. Click on 'Reset' hyperlink. Note: The password may have to be reentered at this point. 8. Click on 'Reset' button. A new network status page should print out after a few minutes. 9. ' This page could not be display' should appear when entering KN306 TCP/IP address in theweb browser. Note: The KN306 must be at firmware version 6.30c. To restore the HTTP TCP port 80, perform the following:1. Verify IPX/SPX* protocol on installed on the workstation. 2. Install the latest version of the MAP utility. 3. Click on the KN306 IPX/SPX name at the home page. 4. Enter 'nic/port' after the 'KCA_xxxxx/' in the URL. The URL should read 'http://workstation'sTCP/IP address:34/KON_999777-HTML/nic/port'. 5. Enter 80 for HTTP TCP port. 6. Enter 'sysadm' for the password.7. Click on 'Accept Settings' button. 'Port Configuration has been successfully updated' messageshould be displayed after few seconds.

USAGE: 0

10Copyright 2003, Konica Business Technologies U.S.A., Inc. May 2003

Page 11: Solution Guide Controller IP-602 Konica 7085

IP-602

Note: KN306 Telnet TCP port is set to 0 then cycle engine OFF\ON for 15 seconds. Ignore steps8 through 13.8. Click on 'Start' button. 9. Click on 'Run'.10. Enter 'CMD' for Microsoft* Windows NT/2000/XP and 'command' for Windows 9x to accesscommand prompt. 11. Type 'Telnet KN306 TCP/IP address'. 12. Enter sysadm for the username and password. 13. Press 4 for 'Reset Unit'. The message should show 'Connection to lost host' on the commandprompt window.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]].

KN306, how to print using the web utility.DESCRIPTION: SOLUTION ID: 147,090

SOLUTION: To print using the web utility, perform the following:1. Open the web browser on the PC and clear the command line.2. Type the TCP/IP* address of the NIC/printer that you want to receive the print job.3. 'Web Utilities Version 3' will be indicated on the monitor display.4. Click on the 'Network Setup' button and then click on 'Network Print Options'.5. Select the file to be printed. Note: The files must be printer ready files such as TXT or PRN files (not TIF or PDF files). Browseto the file. The file can be a local file or from a remote server. 6. Type 'sysadm' in lowercase as the password.Note: If sending a PRN file, it will select the various print options selected in the driver.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

KN306, how to FTP print .DESCRIPTION: SOLUTION ID: 147,077

SOLUTION: Prerequisites: The KN306 must be at least ver.6.30c and only FTP via the DOS command promptworks.

To FTP print, perform the following:1. From a workstation on the network, select the DOS command prompt screen and go to the DOSprompt. 2. Type "ftp" and [enter].3. Type "open" followed by a [space], then the TCP/IP* address of the NIC where the file is to besent, then press [enter].4. The system will respond with "User TCP/IP address of the device: (none)".5. Type PORT1 and [enter]. The response will be "230 User name Okay, logged in."ftp> 6. Type lcd and [enter]. The system will respond with "Local directory now C:\".ftp>7. Type "put" (space) (The file name and extension of the file you want to print) [enter].8. The file will print immediately. The display should indicate "200 Port command OK."150 About to open connection.226 file transferred. Note: The file must be located on the workstation drive and must be one of the following types:TXT, PRN, PCL* or PS. Only these file types are printer-ready files and will print correctly.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

New base system code and printer drivers for the IP602/FORCE 85/7085 printing systems.DESCRIPTION: SOLUTION ID: 146,527

SOLUTION: There are a few different ways to get this code level installed:1. All new shipped orders for the IP602 or Parts Center hard disk drives will be at the new 'base'version 6.0.0 system code, and all that is required is to load the 6.1.0 system code. 2. Download the 6.0.0 and 6.1.0 system code and install the 6.0.0 code, then the 6.10 code viafloppy disks. 3. Download the CD-ROM installation files which allows an upgrade from 5.x.x to 6.0.0 using aCD-ROM drive. Details of this type of installation are included in Section 5 of this bulletin. Thenyou will need to download the 6.1.0 code and upgrade using floppies.CAUTION: If using existing equipment, do not go from version 5.x.x directly to 6.1.0; you must gofrom 5.x.x to 6.0.0, then to 6.1.0. Obtain these system code versions on the [[Konica FTP site|URL ftp://kbtdigital:[email protected]]], or order a new pre-loaded hard drive with version6.0.0 from the Parts Distribution Center using standard ordering procedures.

Newly added functions include:2.1.1) Job Spooler function (PCL* only)2.1.2) Expansion of IP602 built-in HDD access area2.1.3) Alert E-mail function

USAGE: 0

11Copyright 2003, Konica Business Technologies U.S.A., Inc. May 2003

Page 12: Solution Guide Controller IP-602 Konica 7085

IP-602

2.1.4) 7085, FORCE85 tandem support 2.1.5) Constraint on driver when using with FORCE852.1.6) Disabling reading of 600dpi/400dpi resolution2.1.7) Switching to single-sided or double-sided print in a job (mixplex)2.1.8) Multi-language support of KN306 NIC2.1.9) Tab paper printing availability2.1.10) Non-standard paper size availability2.1.11) Two-byte PCL font support for certain Asian characters.2.1.12) Plug-and-play on parallel connection with Microsoft* Windows 2000 and XP2.1.13) PCL driver is Microsoft certified (Microsoft Digital Signature)2.1.14) NDPS for Novell*2.1.15) Face-up/Face-down output modes

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

Unable to print from Tray 3 when using CCH* Tax software program.DESCRIPTION: SOLUTION ID: 146,427

SOLUTION: CAUSE: Printer Setup within the CCH application is not set properly.

SOLUTION: To allow printing from all trays, perform the following:1. From the CCH application, Select File.2. Select Printer Setup.3. Select Use Large Capacity Add-on Printer Tray When Printing Returns.4. Select Properties.5. Select Auto Select For your Paper Source.6. Select OK.7. Select OK again to save settings.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

LinkCom* Xpress, unable to access the print server via Print Guide. LAN link lightconstantly flashes.

DESCRIPTION: SOLUTION ID: 145,866

SOLUTION: CAUSE: LinkCom Xpress was shut down during the upgrade process. It will remain in amicrocode download mode.

SOLUTION: If a LinkCom Xpress does not allow access through the network (continually flashingLAN link light), power up the unit while depressing the Test Switch. Continue to hold the TestSwitch down until a print out occurs on the printer. The printed page will give an indication as towhat issue is occurring. At this time, use the arp -s command from a DOS prompt as outlined in this example:arp -s 10.26.0.78 00-4F-98-28-47-65 Run the arp command three times in quick succession which will ensure that the arp does takeplace. Ping the IP address to verify connection.From the C prompt, enter ftp <ip Address>From the ftp prompt, type in dir which will give an indication as to which version boot and basecode are installed.Enter bin which puts it in Binary mode.Enter hash which allows a visual representation of the download process.Enter put c:\ 156720.b80 which downloads the appropriate firmware to the LinkCom Xpress.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

CDR101 Not Ready is displayed on the monitor when attempting to update the IP602 tosystem code version 6.0.0 using the CDROM ISO file update method.

DESCRIPTION: SOLUTION ID: 145,811

SOLUTION: PROBABLE CAUSES:1. A the ISO image was burned onto a CD-RW (as opposed to CDR) and is not being readcorrectly by the CD player attached to the IDE2 (master). Burn the image onto a standard CD andre-install.

2. Not reading drive Q:The low level CD driver "MSCDEX" (contained in the set-up floppy) may not be adequate for newerCD drives. If the CD drive in use is newer it may require a specific driver. Use a different CD drive(12 speed or less is preferable).

USAGE: 0

How to print using the web utility.DESCRIPTION: SOLUTION ID: 145,348

SOLUTION: To print using the web utility, perform the following:1. Open the web browser on the PC and clear the command line.2. Type the TCP/IP* address of the NIC/printer that you want to receive the print job.

USAGE: 0

12Copyright 2003, Konica Business Technologies U.S.A., Inc. May 2003

Page 13: Solution Guide Controller IP-602 Konica 7085

IP-602

3. 'Web Utilities Version 3' will be indicated on the monitor display.4. Click on the 'Network Setup' button and then click on 'Network Print Options'.5. Select the file to be printed. Note: The files must be printer ready files such as TXT or PRN files (not TIF or PDF files). Browseto the file. The file can be a local file or from a remote server. 6. Type 'sysadm' in lowercase as the password.Note: If sending a PRN file, it will select the various print options selected in the driver.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

When using an i-data* print server, and after installing the SCS daughter card, the followingerror page prints out: LCK5 F 8101: 'DPRAM error. Communication error with IPDS* top.'

DESCRIPTION: SOLUTION ID: 144,194

SOLUTION: PROBABLE CAUSES:1. A bent pin on the SCS daughter board preventing proper communication between it and theNetfusion* card.Remove and repair the bent connector pin(s) on the SCS daughter board and carefully re-install itonto the Netfusion card.

2. IPDS fatal error. Unable to upload IPDS firmware using Print Guide*. Communication failureoccurs after approximately 9 seconds. To correct this issue, upload fslprog.f22 first using PrintGuide, then upload 140130.f22.Note: The fslprog.f22 and 140130.f22 files can be found on the [[FTP site | URLftp://kbtdigital:[email protected]/Black_white_products/Net_fusion_cards/]].

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

User's Reference Guides, IP602.DESCRIPTION: SOLUTION ID: 144,958

SOLUTION: [[Web Utilities 3.0 User's Reference Guide| URL http://techweb.konicabt.com/tpm/media/IP602Web Utility URG.pdf]].[[Job Spooler User's Reference Guide| URL http://techweb.konicabt.com/tpm/media/IP602 JobSpooler URG.pdf]].Note: To view the above PDFs, Acrobat* Reader must be installed. Acrobat Reader can bedownloaded for free from the Adobe* Web site at:[[http://www.adobe.com/products/acrobat/readstep2.html| URLhttp://www.adobe.com/products/acrobat/readstep2.html]]

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

User's Manual, IP602.DESCRIPTION: SOLUTION ID: 144,952

SOLUTION: [[IP511/IP602/PostScript3/KN306 User's Manual| URLhttp://techweb.konicabt.com/tpm/media/IP602 URG.pdf]].Note: To view the PDF, Acrobat* Reader must be installed. Acrobat Reader can be downloadedfor free from the Adobe* Web site at: [[http://www.adobe.com/products/acrobat/readstep2.html|URL http://www.adobe.com/products/acrobat/readstep2.html]]

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

Service Manual/Parts Catalog, IP602.DESCRIPTION: SOLUTION ID: 144,951

SOLUTION: [[IP601M/IP602 Service Manual/Parts Catalog| URLhttp://techweb.konicabt.com/tpm/media/IP602_Service_Manual.pdf]].Note: To view the PDF, Acrobat* Reader must be installed. Acrobat Reader can be downloadedfor free from the Adobe* Web site at: [[http://www.adobe.com/products/acrobat/readstep2.html|URL http://www.adobe.com/products/acrobat/readstep2.html]]

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

When printing through a Microsoft* Windows 2000 server, the customer has to changeoutput paper size from 'A3' (or other paper size) to 'Letter' in the print driver every time theyprint.

DESCRIPTION: SOLUTION ID: 142,175

SOLUTION: CAUSE: The output paper size printer setting on the Windows 2000 server is set to a selectionother than 'Letter'.

SOLUTION: Change output paper size printer setting on the Microsoft Windows 2000 server to'Letter'.Note: The method to change the default output paper size varies depending on the specificprint driver. Contact the System Administrator of the server if assistance is required.

USAGE: 0

13Copyright 2003, Konica Business Technologies U.S.A., Inc. May 2003

Page 14: Solution Guide Controller IP-602 Konica 7085

IP-602

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

Unable to Scan to Network. Network Scan selection is grayed out. Scanning to the mainbody hard drive functions properly along with printing to the IP602.

DESCRIPTION: SOLUTION ID: 141,770

SOLUTION: CAUSE: Network Scanning capability has been deactivated in the 25 mode.

SOLUTION: To activate Network Scanning in the 25 mode, perform the following:1. Access the 25 mode (power ON while pressing the 2 and 5 keys).2. Select [1. Software SW setting]. 3. Use the arrows on the left to scroll to 28.4. Use the arrows on the right to scroll to 1. 5. Press OFF.6. Power the copier OFF/ON to exit the 25 mode.

USAGE: 0

How to print bar code fonts.DESCRIPTION: SOLUTION ID: 141,257

SOLUTION: Bar code fonts are not available from the internal font list and must be sent with each print job inPCL* format only.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

Unable to use Scan to FTP feature. Files will not transfer from the machine to the folder onthe FTP server. The FTP server log file indicates: 550 Cannot STOR. No permission

DESCRIPTION: SOLUTION ID: 148,139

SOLUTION: CAUSE: The root directory to the FTP server in incorrectly input on the operation panel of themainbody.

SOLUTION: In the file path entry on the op panel screen, define the root directory as \ Note: If attempting to enter the file path to the actual folder located on the FTP server (i.e.,c:\konica) an error will occur and will be present in the log file of the FTP server utility for example: > STOR c:\konica/1493.pdf > asked to upload 'c:\konica\1493.pdf' in 'c:\konica\' --> Access denied. > 550 Cannot STOR. No permission. > QUIT > 221 Bye bye ...The reason for this is the FTP server already has c:\konica defined as the root directory. This doesnot have to be redefined on the machine, in fact, doing so will result in the machine attempting toplace files in a directory called c:\konica\c:\konica which does not exist on the FTP server.

USAGE: 0

When printing from Macintosh* running OS 10.2.2, the OS9 (classic) application will crashwhen using the designated Konica PPD file.

DESCRIPTION: SOLUTION ID: 139,561

SOLUTION: CAUSE: Changes made to the operating system in Macintosh 10.2.2 require an update to utilizeKonica's and other printer manufacturer's PPD file. Printing from OS 10.2.x is not available at thistime as Konica does not have an OS10 compatible driver.

SOLUTION: Apple* has released an upgrade to OS 10.2.x to version 10.2.3 to correct the issueswith certain types of ppd files. Please download and install the upgrade if problems occur whenloading the .ppd with OS 10.2.2.

Note: This download is approximately 50 MB's and can be aquired using the updater in OS 10.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

Bugbear Virus FAQ.DESCRIPTION: SOLUTION ID: 138,868

SOLUTION: Q. If I'm infected, what should I do? A. You need to remove Bugbear from your computer with the Bugbear Removal Toolkit. TheBugbear Removal Toolkit is available on the [[Symantec Website| URLhttp://securityresponse.symantec.com]]

Q. How could I have received Bugbear? A. W32/Bugbear-A arrives as an email attachment with a double file extension (.EXE, .SCR or.PIF). The filename itself can be anything, as can the subject line and body text of the email.Infected email could have come from anyone, including your friends. The worm can make up('spoof') who the email is from and the Reply To address, so emails will not necessarily have comefrom the apparent sender. If you are on a network, Bugbear can copy itself to your computer fromanother infected machine on the network, so you might find yourself infected without havingreceived an infected email.

USAGE: 0

14Copyright 2003, Konica Business Technologies U.S.A., Inc. May 2003

Page 15: Solution Guide Controller IP-602 Konica 7085

IP-602

Q. What operating systems does Bugbear run on? A. W32/Bugbear-A runs on Microsoft* Window* 9x, Me, 2000 and XP machines. It is not expectedto run on Windows NT machines, although if the worm is active on a network then it might copyitself to network shares on NT machines.

Q. How can I check to see if I'm infected? A. A quick way to check whether you're infected is to look at your Startup menu. If the worm hasrun on your computer then you should be able to see an EXE file with a three-letter random namein your Startup menu. However, you should use an updated virus scanner to check the computer thoroughly.

Q. Will it steal my credit card number? A. The risk to businesses is minimal but is greater for home users. Bugbear drops a DLL filewhich contains a Trojan that can record keystrokes entered into your computer. If yousubsequently connect to the internet using a dial-up connection, the worm may send the details toa remote encrypted email address. If you are worried, you should contact your bank.

Q. Does Bugbear have any other side-effects? A. Bugbear does not infect files. However, it attempts to copy itself to any available networkresources, which can include printers. The printers themselves cannot be infected, but they maystart to print out the worm's code, which will waste a lot of paper.

Q. How do I stop my printer from printing this garbage? A. Try turning the printer OFF and then ON again. If it continues to print then turn it OFF again. Ifyou can see the queue for the network printer, then try clearing out the outstanding jobs. If not, or ifthat doesn't work, then contact your IT department.

Q. What if I launched the attachment? A. W32/Bugbear-A does not have a damaging payload. However, it will attempt to spread itself toother computers and to send infected emails.

Q. What can I do next time? A. The following guidelines will help prevent future infections: Don't blindly trust attachments. Never open an unexpected attachment. Don't assume that an email is safe just because it comes from someone you know; they could beinfected themselves. Make sure you know how to update your anti-virus software quickly. Avoid sending around jokes and stupid attachments yourself, as it encourages people to treatthem as 'mostly harmless'.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

KN3xx or imbedded NIC (511-422) configuration page outputs KN_999999 and the MACaddress is corrupt.

DESCRIPTION: SOLUTION ID: 136,195

SOLUTION: CAUSE: A brown-out or power surge has caused the card's NVRAM to become corrupt, resultingin the card "forgetting" the serial number and MAC address.

SOLUTION: To restore the information, perform the following:1. Download and install the NIManage utility from Konica's FTP site.2. From the command line, navigate (use CD) to the installation directory and <type>nimanage/nsdoc.3. Select the unit and go to the system menu.4. Select the Network address (displayed as 999999).5. Type the correct serial number (written on the card), click the recalculate button, then click OK.6. When the KN3xx or imbedded NIC (511-422) is rebooted, the correct serial number will bedisplayed and the card can be reconfigured.

USAGE: 0

Unable to have output from AS/400* pick Tray 4 as default. The paper always pulls from Tray1. A previous 7050/IP302 configuration had the ability to set the default tray and ignore thetray calls in the print job.

DESCRIPTION: SOLUTION ID: 135,351

SOLUTION: CAUSE: If the print stream is PCL* with HP* tray calls, the newer controllers (IP304, IP421, IP422,IP431, IP601, IP602, IP511) will require the installation an i-Data* EasyCom Express print server tochange the tray calls. The EasyCom Express print server (Item #950209) can be programmed withsearch and replace; and pre- and post-string print stream entires.

SOLUTION: In this example, if the output from the AS/400 contains an HP print driver call for Tray1 (&l1H), this can be substituted with an tray call to select the default tray set on the machine(&l7H). To achieve this, perform the following:1. Using Print Guide, browse to the EasyCom.

USAGE: 0

15Copyright 2003, Konica Business Technologies U.S.A., Inc. May 2003

Page 16: Solution Guide Controller IP-602 Konica 7085

IP-602

2. Double-click the port used to accept input from the AS/400.3. Select strings and enter: Search for: &l1H and replace with: &l7H This will allow the machines default tray to be selected when print jobs containing (&l1H {HP Tray 1call}) are sent.4. Under Post Strings, enter 0x1bE to call for a reset following the print job.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

A 925 error occurs after creating an NDPS* printer, specifically when entering the TCP/IP*address of the printer when configuring the port handler for the Printer Agent.Note: Depending on the NDPS version, the following errors may be displayed :1. "NDPS ver 2.0 error the print device subsystem could not bind to the requested porthandler, make sure the requested port handler is loaded or correct any failure that the porthandler reported." 2. "PH-2.01-226 system level failure, NDPS printer object, the port handler's call to functiongethostname failed. This may indicate problems with the sys\etc\hosts file or thesys\etc\resolv.cfg" 3. "Not Bound" when creating an NDPS printer in NWAdmin32.

DESCRIPTION: SOLUTION ID: 134,651

SOLUTION: CAUSE: The TCP/IP address and host name of the printer, as well as the TCP/IP address and thehost name of the Netware server are not installed correctly into the etc\hosts file on the server.

SOLUTION: At the server console, type: edit etc\hostsEnter the TCP/IP address of the printer and Printer name as well as the TCP/IP address of theNovell* server and its name. The hosts file has this format:Internet-address official-host-name aliasesFor example, add:136.65.86.216 KCA_001257 (the default name can be viewed via browser or on print out from theKN card at boot-up)136.65.86.217 netwareservernameSave this file and re-create the printer agent. By adding the TCP/IP address and the name of theprinter to the Netware* server's hosts file, the printer is able to find the NDPS manager.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

What cable is required to connect the IP602 to a PC when rewriting firmware?DESCRIPTION: SOLUTION ID: 134,088

SOLUTION: A 25-pin male-to-male parallel cable. USAGE: 0

When printing a scanned image from Adobe Acrobat* 5.0, the lead edge is missing.DESCRIPTION: SOLUTION ID: 133,857

SOLUTION: CAUSE: The settings in the driver and/or application may be causing printing issues.

SOLUTION: From within the application, select File then Print. Choose 'Shrink oversized pages topaper size.'

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

The Auto-Polling function in Scantrip is not saved, even though 'Save Current Settings' ischecked.

DESCRIPTION: SOLUTION ID: 133,450

SOLUTION: CAUSE: When Scantrip is closed, it checks to see if the 'Save Current Settings' is enabled. If it isenabled, Scantrip will save all settings except the Auto-Polling checkbox setting.

SOLUTION: This is correct operation for Scantrip. Due to the numerous requests, the SEC is nowlooking into adding this feature into the next version of Scantrip. Please continue to monitor[[Konica SEC website| URL http://www.sec.konicabt.com/main.html]] for the availability of the newScantrip version.

USAGE: 0

NDPS (Novell* Distributed Print Services) drivers do not install on a Microsoft* WindowsNT/2000 client.

DESCRIPTION: SOLUTION ID: 133,187

SOLUTION: CAUSE: Requires a service pack update.

SOLUTION: Update to [[Service Pack 3 for Novell client| URLhttp://support.novell.com/cgi-bin/search/searchtid.cgi?/10064774.htm]].

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

16Copyright 2003, Konica Business Technologies U.S.A., Inc. May 2003

Page 17: Solution Guide Controller IP-602 Konica 7085

IP-602

When installing a printer driver with the Novell* NDPS installer, the printer driver is notdisplayed or an error is produced.

DESCRIPTION: SOLUTION ID: 133,215

SOLUTION: CAUSE: The NDPS database on the Novell server is not properly synchronized.

SOLUTION: Synchronize the NDPS database.

From the server console, using NDPS MGR. NDPS MGR and Status CONTROL Database Options (see list) Resynchronize Database files

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

The IP-P2P (peer-to-peer) redirected port is not listed under 'Print to the following port' dropdown field within the print driver properties.

DESCRIPTION: SOLUTION ID: 133,012

SOLUTION: CAUSE: The 'select' (S) flag was not enabled within the IP-P2P utility.

SOLUTION: To enable 'select' (S) flag within IP-P2P utility, perform the following:1. Click on Start button. 2. Click on Programs.3. Click on IP-P2P. 4. Click on Printers button. 5. Click on the available printer entry in the 'Available Printers' field.6. Click 'Select' button. 7. Click OK twice. 8. Verify redirected port can be selected within 'Print to following port' drop down menu within printdriver properties. 9. Click Apply button to accept the change. SPECIAL NOTE: Solution provided by Victor Miranda, Integration Specialist, KBT Long Island.

USAGE: 0

Is Scantrip or Scantrip Admin compatible with Citrix Metaframe* or Microsoft* WindowsTerminal Server?

DESCRIPTION: SOLUTION ID: 130,805

SOLUTION: Scantrip and Scantrip Admin v1.5 are not currently compatible with Citrix Metaframe or TerminalServer based on the licensing method being used. The program can only be licensed for one useron the server. As the Adminstrator is the only individual that can install programs on the server, theAdministrator is the only user that will be able to use Scantrip. The SEC department is working ona solution for this issue.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

Unable to communicate with the IP unit.DESCRIPTION: SOLUTION ID: 130,965

SOLUTION: CAUSE: DSL or cable broadband internet connection was recently installed. This may cause theTCP/IP scheme on the network to change.

SOLUTION: Work with the network administrator to edit the IP address for the printer or router toallow the printer to work properly on the network.SPECIAL NOTE: Solution provided by Jerry Murri, Integration Specialist, KBT Oakland

USAGE: 0

Connected product installation information form.DESCRIPTION: SOLUTION ID: 130,874

SOLUTION: The [[KNAS Additional Information Form| URLhttp://techweb.konicabt.com/tpm/media/knas_additional_info.pdf]] is informational in nature and isrecommended as an installation guide. While it may be helpful to have customers provide theinformation on the form, it is technical in nature and will most likely require a connected productexpert to coordinate completion with customers. This form may supplement KNAS forms but it isnot required with KNAS submissions.Note: To view the PDF, Acrobat* Reader must be installed. Acrobat Reader can be downloadedfor free from the Adobe* Web site at: [[http://www.adobe.com/products/acrobat/readstep2.html|URL http://www.adobe.com/products/acrobat/readstep2.html]].SPECIAL NOTE: This form was provided by Roland Koennecke, KBT Houston.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

Where to get an IP address calculator.DESCRIPTION: SOLUTION ID: 130,854

SOLUTION: A freeware version of an IP address calculator is available at [[www.radmin.com| URLhttp://www.radmin.com/ipcalc11.zip]].

USAGE: 0

17Copyright 2003, Konica Business Technologies U.S.A., Inc. May 2003

Page 18: Solution Guide Controller IP-602 Konica 7085

IP-602

Printers on the network are printing garbage and no print job was sent in any case.DESCRIPTION: SOLUTION ID: 138,897

SOLUTION: CAUSE: A computer or computers have been "infected" with the Bugbear virus.

SOLUTION: Try powering the printer OFF/ON. If it continues to print, then power it OFF again. Ifthe queue for the network printer can be viewed/accessed, then try clearing out the outstandingjob(s). If not, or if unsuccessful, then contact the IT department to eliminate the virus.

USAGE: 0

When is Print Services Facility (PSF) required?DESCRIPTION: SOLUTION ID: 130,022

SOLUTION: Print Services Facility is required when using advanced printing data streams on an AS/400*, andprinting these data streams over a LAN. These advanced data streams are IPDS or AFP. Theeasiest way to know if either of these data streams are being used, is to ask the user whethergraphics or forms overlays are being printed. If so, then PSF will be required to print these datastreams over a LAN.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

How can an IPDS* mixplex document print correctly?DESCRIPTION: SOLUTION ID: 130,003

SOLUTION: This solution assumes that the reader can edit and save documents. Also that the user is familiarwith up/down loading configurations to the i-data*/netfusion devices. This solution is rathercomplex and should not be performed by novice computer users without the supervision of theNSSG.

An external i-data box or NetFusion card with the IPDS option installed will be required. With a fullyconfigured print server, use PrintGuide to download the configuration to the desktop. Open the filewith notepad or WordPad. Locate the entry for Printer 1. Under the DUPLEXINSTALLEDcommand, enter the following two lines:

PREPRINTEDDUPLEX 1ROTATEDUPLEX 3

Under the TRAY_DEF entries. Add the following command for the drawer that is to print mixplexjobs:

PREPRINTED YES

Save the file as TXT and upload the file to the print server device.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

How to program the machine to automatically delete scanned jobs on the hard drive inconjunction with the use of the Scan to HDD feature.

DESCRIPTION: SOLUTION ID: 129,548

SOLUTION: To program the machine to automatically delete scanned jobs from the hard drive, perform thefollowing:1. Press the MODE key to select PRINTER.2. Press Controller Set on the touchscreen.3. Press the DOWN arrow one time.4. Press ScanDataAutoDel on the touchscreen and press OK.5. Select one of the following options: OFF, 12hour, 24hour, 2days, 4days, 6days, 8days or10days and press OK.6. Press the MODE key and select COPY to return to normal mode.

USAGE: 0

What is the LPR port name for a Microsoft* Windows NT 4.0 queue?DESCRIPTION: SOLUTION ID: 127,723

SOLUTION: The LPR port name is 'LPDPRT1'. The port name must be in uppercase letters.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]].

USAGE: 0

What is the latest microcode for Ethernet i-data* box?DESCRIPTION: SOLUTION ID: 127,704

SOLUTION: The latest microcode for the Ethernet i-data box:Base code 104.410 FSL TOP 140.130

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

18Copyright 2003, Konica Business Technologies U.S.A., Inc. May 2003

Page 19: Solution Guide Controller IP-602 Konica 7085

IP-602

Why does pagination change when printing any document using the Konica print driver?DESCRIPTION: SOLUTION ID: 127,535

SOLUTION: Explaining pagination differences between different manufacturers print drivers

This situation is not uncommon in the printing world. Commonly, documents will be formatteddifferently when printed to printers made by different manufacturers. There are many reasons forthis. Due to physical differences between printers, as well as copyright laws, differentmanufacturers will use different programs for their drivers. It is the driver that does the majority ofthe formatting for the image to be placed on the page. Different drivers will use different algorithmswhen imaging spacing and font metrics. Often times, this results in a slightly different look orformat for a document when printed to two different printers. There is also potential differences within the image areas of the main bodies of the two printers.The print controller takes the image area into account when laying out the image on the paper.Different image areas can determine different layouts. These factors can result in lines of textbeing moved on the paper. If lines are moved enough, or lie close enough to the threshold of theimage area, text and page breaks that are rendered in a certain position on one printer may berendered in a different position on another.This scenario will occur across the board for printer manufacturers. A Lexmark* is different from anEpson* which is different than an HP*, etc. Obviously, the output from certain printers will matchup closer to some printers than others. The effect of this behavior can be reduced somewhat byprinting with a common standard PDL such as PostScript*. Alternatively, the customer can printwith a common driver to both printers. In other words, one can print to the HP using the Konicadriver or vice versa. In this way, at least the driver-generated output would be the same going toboth machines. While the output still may not be exactly the same, the effect of printing to twodifferent printers can be lessened. There may even be different output within the same printermanufacturer (i.e., Konica IP302 print controller is good, but the IP304 print controller is not;Lexmark Optra K1220 is good, but the Optra T614 is not).The analogy that is often used when explaining this to customers involves motor vehicles. A Fordand Dodge are essentially the same in terms of the fact that they are cars that serve as a means oftransportation, just as two printers are output devices. However, while the end result of driving twodifferent cars is essentially the same, there may be certain differences with regard to cornering andacceleration that give each car a distinct feel. This is essentially what is happening between thetwo printers.It is understandable that the customer does not want to convert thousands of existing documents,but due to the vast number of different printers currently available on the market today, it is notpossible to exactly emulate all printer manufacturers' algorithms. The only other option is to pickone printer model, format these documents that need a consistent look for that printer, and use onlythat particular printer to print these documents. If there are any further questions, please feel freeto contact the National Systems Solutions Group at 1-800-825-5664.

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

Unable to print using the IP-P2P (peer-to-peer) utility on a Microsoft* Windows XPworkstation.

DESCRIPTION: SOLUTION ID: 126,214

SOLUTION: CAUSE: The IP-P2P utility is compatible with Windows 9x and ME clients for printing directly fromthe workstation to the printer. This utility is not recommended with Windows XP.

SOLUTION: The UNIX* print services (direct TCP/IP* printing via LPR port) that are included as apart of Windows XP can be used to print directly from the workstation to the printer (as analternative to the IP-P2P utility).

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]

USAGE: 0

How to insert pre- and post-string characters when printing using i-data* print servers (i.e.,EasyCom*, PlusCom*, LinkCom*) in order to substitute print stream parameters to correct ormodify PCL* print jobs.

DESCRIPTION: SOLUTION ID: 123,930

SOLUTION: With an i-data print server installed, the Print Guide* Utility can be used to define pre- andpost-strings.A pre-string is a string of characters sent to the printer before each print job; a post-string is sent tothe printer after each print job. The printer can also replace strings; that is, automatically substituteone string for another. Use this feature if needing to customize the printer setup for particular print jobs. Customizedsetups could include, for example, font selection, printer reset, formfeed, bannerpage, or load aform.To customize printer setup, perform the following: 1. Display the PrintServer Advanced Configuration web page. 2. Click Logical Printers. 3. Click on the logical printer in the list whose setup is to be changed. The Configure LogicalPrinter web page is displayed. 4. Edit the pre-, post-, and replace strings in the adjacent text fields.

USAGE: 0

19Copyright 2003, Konica Business Technologies U.S.A., Inc. May 2003

Page 20: Solution Guide Controller IP-602 Konica 7085

IP-602

Note: The replace string syntax is [string1], [substitution1]; [stringN], [substitutionN] 5. Click Save. To define/edit string settings directly, click Text and type in the string text in the adjacent field.Right click and a menu containing the most common special characters appears. When one ofthese special characters is selected, the code for the character is inserted into the text (at thecursor location).To use pre- or post-string settings defined in a file, click Read from file and type in the pathspecifying the file location in the PrintServer. Download the file to the PrintServer file system usingFTP. It is recommended to put the file in the PrintServer '/config' directory.Pre-, post- and replace string definitions cannot use more than 250 characters each. The numberused in each case is shown below the text field.Read from file on replace strings is only available for PrintServers using firmware numberS80xxx.550 or higher. On earlier versions of PrintServers, Replace String Settings can only bedefined by directly typing them in.Notes:1. Restart the PrintServer before any changes made in pre-, post- and replace string settings areapplied to print jobs2. Double-quote (") must be written as hex code (0x22). Otherwise the string will be truncatedafter the first double-quote.Example: "Hello" is written as 0x22Hello0x22. PrintGuide automatically changes double-quotes to hex values as you type.

EXAMPLES1. This simple example writes the text "This text will be sent before" before the job, and "This textwill be sent after" after the job:Pre string: This text will be sent beforePost string: This text will be sent after

2. This example is used to print Unix jobs on a PCL compatible printer. It inserts a carriage returnfor every linefeed , before each job, and a formfeed after each job:Pre string: 0x1b&k2GPost string: 0x0c

3. This example inserts a form feed after each job:Pre string: Post string: 0x0c

4. This example writes a bannerpage before the job, and adds a formfeed at the end: Pre string: * * * * * * Start of new print job * * * * * 0x0c Post string: 0x0c

5. This example resets an HP and PCL compatible printer:Pre string: 0x1bE Post string:

6. This example selects Landscape paper orientation on an HP and PCL compatible printer:Pre string: 0x1bE0x1b&l1O Post string: 0x1bE0x0c

7. This example selects CG Times 12p font on an HP and PCL compatible printer:Pre string: 0x1bE0x1b(0U0x1b(s1p12v0s0b4101T Post string: 0x1bE

8. In this example, a PCL compatible printer changes the orientation of the paper to landscapewhen it encounters the text $landscape$ at the top of a page, and changes the orientation of thepaper to portrait when it encounters the text $portrait$ at the top of a page:Replace: $landscape$, 0x1b&l1O; $portrait$, 0x1b&l0O

*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]