solar water heating basics progress energy florida solar water heater incentive program colleen...
TRANSCRIPT
Solar Water Heating Basics
Progress Energy FloridaSolar Water Heater Incentive
ProgramColleen Kettles
Florida Solar Energy Research & Education Foundation (FlaSEREF)
Solar Water Heating Basics How It Works How Much Energy It Saves How It Helps the Environment How To Purchase How Much It Costs What Incentives Are Available
Types of Systems
“Active” System Direct Pumped
Water is the collector fluid Freeze protection provided by drain-back
tank or freeze valves Indirect Pumped
Anti-freeze is the collector fluid Heat exchanger utilized within storage
tank
Active Solar Water Heater
Active Solar Water HeaterDirect Pumped
Active Solar Water HeaterDirect PV Pumped
Active Solar Water HeaterIndirect Pumped
The Collector
Active Systems Use “flat-plate” collector Insulated box with ½” copper piping
integrated into a black absorber and glass cover
Fluid is water or anti-freeze Designed to reach temperatures as
high as 160° F
The Storage Tank
Active System Specially designed, heavily insulated
tank (R value of 16 or greater) Sizes range from 52 to 120 gallons for
residential applications Has only a top electric element In a system using antifreeze, the tank
will have an internal heat exchanger
Balance of System Components
Active System Pump (ac or dc) Differential Controller, or Photovoltaic Panel Assorted valves and vents Copper Piping Insulation
Types of Systems
“Passive” System Integral Collector Storage
Collector provides additional water storage
No moving parts
Passive Solar Water HeaterIntegral Collector Storage
Passive Solar Water HeaterIntegral Collector Storage
The Collector
Integral Collector Storage (ICS) The collector is also the storage medium Insulated box with 4” copper tubing
welded together to serve as the absorber Glass cover Fluid is water Designed to reach temperatures as high
as 160° F
The Storage Tank
Integral Collector Storage (ICS) Collector provides ½ of the storage
(32-50 gallons) Existing or conventional tank provides
the balance of storage
Balance of System Components
ICS System Assorted valves and vents Anti-scald valve (optional) Copper piping Insulation
Types of Systems
“Passive System” Thermosiphon
Tank is roof mounted above collector
Uses flat plate collector No moving parts Reminiscent of early solar
systems
Early Thermosiphon Solar Water Heater
Thermosiphon System
Passive Solar Water HeaterThermosiphon System
The Collector
Thermosiphon System Uses “flat-plate” collector Insulated box with ½” copper piping
integrated into a black absorber and glass cover
Fluid is water or anti-freeze Designed to reach temperatures as
high as 160° F
The Storage Tank
Thermosiphon System The storage tank is specially designed
to be mounted on the roof above the collector
An auxiliary tank with electric element is installed in the home
Balance of System Components
Thermosiphon System Assorted vents and valves Copper piping Insulation
Household Hot Water Use 15% – 20% of total household
energy consumption Daily usage is 20 gallons each per
day for the first two occupants; 15 gallons per day for each additional occupant
Example: Four person household will use 70 gallons of hot water and will need 80 gallons of storage
Collector BTU Ratings/Solar Fraction Central Florida ambient water
temperature is 72 degrees Solar fraction is the proportion of
hot water provided by the solar system
Optimal solar fraction is 70% and is based upon annual performance
Collector Btu Ratings/Solar Fraction 38,000 Btus will be needed to raise
80 gallons of cold water to 122 degrees
A 32 square foot ICS system is rated at 28,700 Btu/day and will provide a 77% solar fraction
A 40 square foot active collector is rated at 34,400 Btu/day and will provide a 92% solar fraction
Savings
The kWh equivalent of 38,000 Btu/day is 11.13 kWh per day x 365 days = 4,063 kWh/year (electric load) A solar fraction of 70 will offset 2,844 kWh A solar fraction of 77 (28,700 Btu/day) =
8.4 kWh/day x 365 days, saves (or produces) 3,066 kWh/year
A solar fraction of 92 (34,400 Btu/day) = 10 kWh/day x 365 days, saves (or produces) 3,650 kWh/year
Savings
At an average residential rate of $.115 per kWh:
A solar fraction of 70 will save $325/year
A solar fraction of 77 will save $350/year
A solar fraction of 92 will save $420/year
Back-up Hot Water All solar water heaters will have a
conventional energy back-up No consumer action is required to
activate the back-up Back-up is needed for periods of
excessive hot water use or inadequate solar resource
How It Helps the Environment Emission Reductions (One Solar
Water Heater Saves Annually) Carbon Dioxide (5,000 lb) Sulfur Dioxide (20 lb) Nitrogen Oxide (12 lb)
Renewable Energy Credits The “environmental attributes” of
solar energy are a commodity
How to Purchase Contact reputable solar companies
www.flaseia.org www.findsolar.com
Verify contractor licenses www.myfloridalicense.comVoice: 850-487-1395 Solar contractor (CV) Specialty solar (CW) Plumbing contractor (CF) Local solar license (RX)
How to Purchase Get more than one estimate, and
get them in writing Avoid high pressure sales tactics Compare system types, sizes,
prices and warranties Ask for FSEC system certification Ask for local references
How to Purchase A local building permit should be
obtained prior to installation (although some jurisdictions no longer require)
Contractor, not the homeowner, is responsible for the permit
If in doubt, homeowner should contact the local building department
Deed restricted communities will typically require prior approval (which cannot be denied)
How Much It Costs Cost of a system varies depending
upon the type of system and the size of system
Prices range from $3,000 to $5,000 in general
Rising material costs and the cost of doing business (gasoline, insurance, etc.) have resulted in price increases
Financial Incentives Incentives are designed to lower
the cost to the consumer Sales Tax Exemption (6-7%) Florida Solar Rebate ($500) Progress Energy Rebate ($450) Federal Tax Credit (30% with cap
of $2,000)
Interaction of Incentives Rebates should be deducted from
the cost of the system before the federal tax credit is calculated
IRS has not issued regulations under this tax credit law
Exception would be if rebates are included as gross income
Interaction of Incentives
Example –System cost: $4,000State rebate: - $500PEF rebate: - $450Actual cost: $3,050
Federal tax credit: (.30 x 3,050) = $915Net system cost: $2,135
Impact of Incentives on Consumer Savings
Net System Price of $2,135 Annual Savings of $325 = 6.5 year
payback Annual Savings of $350 = 6.1 year
payback Annual Savings of $420 = 5 year
payback
For More Information www.flaseref.org www.flaseia.org
www.fsec.ucf.edu www.floridaenergy.org
800-59SOLAR
THANK YOU