Page 1: SMT 300 Smoke Machine Tester Operator ManualSMT 300 Universal Filler Neck Adapter (F00E900362) Allows direct connect of the SMT 300 smoke output hose to most fuel tank filler necks

F00E900291

SMT 300 Smoke Machine Tester Operator Manualwith UltraTraceUV® Dye Solution

Page 2: SMT 300 Smoke Machine Tester Operator ManualSMT 300 Universal Filler Neck Adapter (F00E900362) Allows direct connect of the SMT 300 smoke output hose to most fuel tank filler necks

Robert Bosch LLC SMT 300 Operator Manual | Version 1 | January 2011

ii | Contents | SMT 300 Operator Manual

TO PREVENT PERSONAL INJURY AND/OR DAMAGE TO VEHICLE OR EQUIPMENT• Usethisequipmentinthemannerspecifiedbythe

manufacturer.• Understandoperatingprocedures/followallsafety

precautions.• CorrectlyconnectSMT300testertobatteryand

chassisground.• UseUltraTraceUV®SmokeSolutionNo.

F00E900348inthisSMT300tester.Alteringthesolution,hoses,cablesoranyotherreplacementpartsmaycausedamagetovehiclesbeingtestedandmaycausepersonalinjury.

• NEVERusewithrunningvehicleengine.• NeverleavetheSMT300tester’shosesorpower

cablesconnectedtothevehicleforextendedperiodsoftimewhentestsarenotbeingperformed.

• Donotperformtestnearsourceofsparkorignition.

• Itisessentialthatthe12VDCbatterysourceyouusetopowertheSMT300testerisingoodconditionandfullycharged.

• WeareyeprotectionthatmeetsOSHAstandards.• Followsafetyprecautionswhenusingultraviolet

lightsource.• Airpressureornitrogensourcetotestercanbe

between50-175PSI(3.4to12bar).• StoreandoperatetheSMT300testerinupright

position.• Usewithanon-combustiblegas,suchasnitrogen,

argonorCO2,whentestingavehicle’sfuelvaporrecovery(EVAP)system.

• Smokeexitingaverysmallleakissometimeseveneasiertoseeifafterfillingthesystemwithsmokeyoureducethesmokeflowbyturningtheflowcontrolknobclockwise,whichslowstheexitingsmokevelocityandhelpsyouseeverysmallleak(s).

• Usethewhitelightprovidedtohighlightthesmokeexitingaleak.

• UsetheUltraviolet(UV)lightandyellowglassesprovidedtolookforthefluorescentdepositattheexactlocationofaleak.WhenusingalternatesourceofUVlight,besureitisonethatcoversthe400nanometer(nm)UVlightrange.

• WhenoperatingtheSMT300testerinnearfreezingtemperatures,cycletheoperationoftheSMT300tester15secondsONand15secondsOFFforapproximatelythefirstminuteortwoofoperation.ThiswillallowtheSMT300testertoreachitsoptimumoperatingtemperature.

• Whentestinganengine’sintakeorexhaustsystemforleaks,itisrecommendedthattheenginebecold.Smallleaksmaybesealedduetothermalexpansion.

Contents

1 Introduction

1 SMT 300 Technical Specifications

2 Items Included with the SMT 300 Tester

3 Optional SMT 300 Accessories

4 Initial Setup

5 SMT 300 Tester Front View

6 SMT 300 Tester Rear View

7 Basic Testing Procedure

7 Optional Gas Source

8 Flow Meter Overview

9 EVAP Tech Tip

10 Control Valve Overview

11-13 Sample Leak Detection Applications

14 SMT 300 Troubleshooting Guide

15 SMT 300 Warranty

16-17 Notes

NOTICEPlease note that the instructions in this Operator Manualareintendedtoonlyprovidegeneralandbasicinformationtotheuser.Thismanualisnotintendedtobeanexhaustivediscussionanditisnotintendedasprofessionaladviceonthemattersorproceduresinquestion.Whilerecommendationsandsafetyprecautions/warningsareprovidedforinthismanual,itisnotintendedtobeasubstituteforyourcommonsense.

Page 3: SMT 300 Smoke Machine Tester Operator ManualSMT 300 Universal Filler Neck Adapter (F00E900362) Allows direct connect of the SMT 300 smoke output hose to most fuel tank filler necks

SMT 300 Operator Manual | Version 1 | January 2011 Robert Bosch LLC

SMT 300 Operator Manual | Introduction | 1

Thank You and Congratulations!Youareinpossessionofthemostuseful,yetsimpletooperate,leaktesteravailabletoday.ThepatentedtechnologiesinthismodelSMT300testerweredevelopedincollaborationwithmajorautomakerstospecifiedstandardsanddesignedtobesafetouseinanyvehicle.ItistheonlysmoketechnologyapprovedbyanyautomakerintheworldandistheonlyonethatmeetsSAEInternationalPapers’recommendationsforsaferfuelevaporative(EVAP)testing[2007-01-1235&2008-01-0554].

ThisSMT300testerproducesaspecialsmokevaporknownasDiagnosticSmoke®.Itisdesignedtofindleaksinanylowpressureclosedsystem,aswellaspinpointwindandwaterleaksenteringthevehicle’spassengerortrunkcompartment.TheUltraTraceUV®dyesolutionthetesterusesistheonlyautomaker(OEM)approvedsolution.Tolocatealeak;yousimplyintroducethesmokevaporintothesystemtobetestedandshinethewhitelightsuppliedtolookforthesmokeexitingtheleak.Orusetheultraviolet(UV)lightsuppliedtoviewthefluorescentdyedepositedattheexactlocationofaleak.Ifyouseethesmokeorthedye,you’vefoundtheleak.

SMT 300 Technical Specifications:Height 13in.(33.0cm)

Length 13in.(33.0cm)

Width 12in.(30.5cm)

Weight 19lb.(8.6kg)

Shippingweight 24.5lb.(9.5kg)

Power supply 12voltsDC

Powerconsumption 15amps.

SolutionMax.Volume 12oz.(355ml)

Supply pressure 13.0in.H2O(0.032bar)

Supplyvolume 12litersperminute

Smokesupplyline 10feet(3m)

Power supply line 10feet(3m)

Operatingtemp.range 45°Fto140°F(7.2°Cto60°C)

Altitude Upto6,561Ft(2,000M)

MaximumRelativeHumidity

80%forTemperaturesupto140°F(60°C)

ConditionsofUse Indoor/Outdoor(ifnotwet)

PollutionDegree 2

UltraTraceUV®; the proper solution to use in your SMT 300 Smoke MachineTester.

A common question asked is if one can use a basic generic mineral oil, such as ‘baby oil’, in the tester to create the smoke.

Youcanifyouwantto,butwedon’trecommendit.ThepatentedUltraTraceUV®smokesolutionsuppliedwiththistester;willperformhundredsofteststhatonlycostpenniespertest;istheonlysolutionintheworldapprovedbytheautomanufacturers;andwillnotvoidanyvehiclefactorywarranties.Plus,youhavetheaddedbenefitofthetracedyethatmarkstheexactlocationofaleak,increasingdiagnosticaccuracyunlikeanyother.Thisspecialsolutionisnota“generic”mineraloil.Infact,genericmineraloilsarenotintendedforthistypeindustrialuse.Thegenericmineraloilsbreakdown,asevidencedbyafoulodorandcoulddamagevehiclecomponents.

Page 4: SMT 300 Smoke Machine Tester Operator ManualSMT 300 Universal Filler Neck Adapter (F00E900362) Allows direct connect of the SMT 300 smoke output hose to most fuel tank filler necks

Robert Bosch LLC SMT 300 Operator Manual | Version 1 | January 2011

2 | Items Included | SMT 300 Operator Manual

Items Included with the SMT 300 Smoke Machine Tester

UltraTraceUV® (F00E900348)Thispatentedsolutionistheonlyautomaker-approvedsmoke-producingsolution.Thesolution’schemistrycontainsaspecialdyethatdepositsattheexactlocationofaleak.Eachbottlewillperformapproximately300fullcycletests.(12oz./355ml).SMT300isshippedwithtwo(2)bottles.Replenishmentpart#F00E900348isone(1)bottle.

Cap Plugs Kit (F00E900349)Usefulwhensealinganintakemanifoldsysteminordertocontainthesmokeinthesystemforproperleaktestingsuchas;massairflowsensorducting,etc.

Adapter Cone (F00E900350)Forintroducingsmokeintotheexhaustsystemorintoanyorificethataccommodatesthecone’ssize,suchastheinductionsystem.

Smoke Diffuser (F00E900351)Designedtolocateleaksarounddoors,windowssunroofsandtrunkcompartment.

Combination Light (F00E900352)Turnitonanditdeliversawhitelight,foreasiersmokelocation.Clickitagainanditdeliversanultraviolet(UV)lightthathighlightsthefluorescentdyedepositedattheexactlocationofaleak.Clickitathirdtimetoactivatethelaserpointer.Kitincludeslight,amberglassesandbatteries.

Standard Size EVAP Service Port Fitting (F00E900353)

Schrader Removal / Installation Tool (F00E900354)

NOTE: Theseitemsareprovidedwithinaseparateaccessorystoragecaseandareavailableasreplacementitemsaswell.PleaseorderthenotedF00E900XXXpartnumber.TheaccessorycasereplacementisF00E900364.

Page 5: SMT 300 Smoke Machine Tester Operator ManualSMT 300 Universal Filler Neck Adapter (F00E900362) Allows direct connect of the SMT 300 smoke output hose to most fuel tank filler necks

SMT 300 Operator Manual | Version 1 | January 2011 Robert Bosch LLC

SMT 300 Operator Manual | Optional Accessories | 3

Inert Gas Pack (F00E900355)20oz.liquidCO2bottleandregulatortouseinlieuofshopair.ProvidesthesafestwaytotestEVAPsystemleakage.Fullyfilledbottleprovidescapacityfor25fullcycletests.RefertotheOperatorManualforfulldetails.(CO2 bottlearrivesempty).

100psi pre-set Nitrogen Regulator (F00E900365) For use withlargernitrogenbottlesintheshop.Connectstothelargebottlestandardoutletfitting.UsewithcylinderhoseP/NF00E900366.

Nitrogen Regulator/Cylinder Hose (F00E900366) Connects the SMT 300 inlet to the optional 100psi NitrogenRegulatorP/NF00E900365.

SMT 300 Replacement Filter Kit (F00E900361) ReplacementelementfortheSMT300internalfiltersystem.ProtectstheSMT300fromworkshopaircontaminants.Yearlyreplacementisrecommended.

SMT 300 Universal Filler Neck Adapter (F00E900362) AllowsdirectconnectoftheSMT300smokeoutputhosetomostfueltankfillernecks.Fueltankandperipheralcomponenttestingisthusmadeeasier.

SMT 300 BMW-Mini Fuel Filler Neck Adapter (F00E900363)Allowsdirect&specificconnectionoftheSMT300smokeoutputhosetoBMWandMinifueltankfillernecks.Fueltankandperipheralcomponenttestingisthusmadeeasier.

Air FittingTwoaresupplied.TheautomotivestylefittingisalreadyinstalledontheSMT300.Thesparefittingisanindustrialstylefittingbutalsoapopularoneinautofacilities.

Optional SMT 300 Accessories

Page 6: SMT 300 Smoke Machine Tester Operator ManualSMT 300 Universal Filler Neck Adapter (F00E900362) Allows direct connect of the SMT 300 smoke output hose to most fuel tank filler necks

Robert Bosch LLC SMT 300 Operator Manual | Version 1 | January 2011

4 | Setup | SMT 300 Operator Manual

1. Fill with Solution

PriortousingtheSMT300testerforthefirsttime;pourtheentirecontentsofone12oz.(355ml)smokesolutionbottlesuppliedintothemachine.

Initial Setup/Prior to Turning the SMT 300 Smoke Machine Tester ‘ON’

WedonotrecommendintroducingasolutionintotheSMT300testerthatisnotrecommendedbythemanufacturerbecauseitmaydamagethevehiclesbeingtestedandmayaffecttheirfactorywarranty.Itcouldalsocauseharmtotheoperator!

2. Proper Air Fitting

TwocommonlyusedmaleairfittingsaresuppliedwiththeSMT300tester.Besureoneofthesefittingsisthecorrectfittingforyourfemalehoseconnector.OtherwiseinstallcorrectfittingontotheSMT300tester.UseTeflon®threadsealer.Donotover-tighten.

� AirinletpressuresuppliedtotheSMT300testercanbebetween50and175PSI(3.4to12bar).

[Note:optimuminletpressureis90PSI/6.2bar]

AlwaysmaintainsolutionlevelatornearFULLmark.

AirFitting

Full

Low

Page 7: SMT 300 Smoke Machine Tester Operator ManualSMT 300 Universal Filler Neck Adapter (F00E900362) Allows direct connect of the SMT 300 smoke output hose to most fuel tank filler necks

SMT 300 Operator Manual | Version 1 | January 2011 Robert Bosch LLC

SMT 300 Operator Manual | Front View | 5

SMT 300 Smoke Machine Tester Front View

A. Smoke Solution Fill Port and Dipstick

B. Supply Hose w/ Delrin® Nozzle Length: 10 ft. (3.16M)

C. Function Indicator LightsD. ON | OFF Switch

E. Flow Control Knob

F. Pressure/Vacuum Decay Gauge

G. Flow Meter

A Smoke Solution Dipstick usedtofillandmaintainpropersmokesolutionlevel.

B Smoke Supply Hose

C Function Indicator LightsgreenbatterylightturnsONwhenconnectedto12-VoltDCpower.

� Blinks1-persecondifpowersourceisinsufficient.

� RedON/OFFlightturnsONwhenyoupressthe<ON>button,indicatingsmokeproduction.

D ON | OFF Switch Pushtoturn<ON>smokeproductionfor5minutes.

E Flow Control Knob TESTdelivers‘non-smoke’air.SMOKE(fullopen)deliversfullvolumeofsmoke.ApositionbetweenSMOKEandFLOWCONTROLdeliversvaryingdegreesofsmokevolume.

F Pressure/Vacuum Decay Gauge usedtoverifyifthereisaleakinthesystem.TotestusingPressure-Decay;fillthesystembeingtested,withtheSMT300ineitherTESTorSMOKEsetting.Oncefull,turnSMT300OFF.Observethepressuregaugefordecay,whichwouldindicatealeak.TotestusingVacuum-Decay;besuretheSMT300isturnedOFF.PlaceaTeefittingbetweentheSMT300supplylinenozzleandthesystembeingleaktested.AttachahandvacuumpumptotheTeeanddrawvacuum.ObservetheSMT300vacuumgaugetobesureyoudonotdrawmorevacuumthanthegaugeallows,oritwilldamagethegauge.Stopdrawingvacuumoncepropervacuumisachieved.Observethegaugefordecay,whichwouldindicatealeak.

NOTE: Thepressure/vacuumdecaytestscannotdeterminethesizeoftheleak(s).Leaksizecanbedeterminedusingtheflowmetertest,describedonpage8.

G Flow Meter indicatingflowcouldindicatealeakinthesystembeingtested.Ifthemeterindicatesnoflow,thenyouknowthereisnothingflowingthroughthesystembeingtested(orindicatesnoleak).

Do not runthevehicleenginewiththesupplyhose(itemB)connectedtothevehicle.Normalenginevacuumwilldamagethepressure/vacuumgauge.

Page 8: SMT 300 Smoke Machine Tester Operator ManualSMT 300 Universal Filler Neck Adapter (F00E900362) Allows direct connect of the SMT 300 smoke output hose to most fuel tank filler necks

Robert Bosch LLC SMT 300 Operator Manual | Version 1 | January 2011

6 | Rear View | SMT 300 Operator Manual

SMT 300 Smoke Machine Tester Rear View

H. Air / Inert Gas Fitting

I. 12-Volt DC Power Cables Length: 10 ft. (3.16M)

J. Internal Filter Drain Port

H Workshop Air Fitting / Inert Gas Fitting connecttoshopairforgeneralpurposeleaktestingortoaninertgas,suchasnitrogenorCO2,whentestingafuelevaporativesystem.

I. 12-Volt DC Power Cables connecttopositivebatteryterminalandchassisground.

J. Internal Filter Drain Portthistesterisequippedwithaninternalfiltersystemthatprotectsthetesterandvehiclefromworkshopaircontaminants.

Occasionalfluiddrainage,fromPort‘J’,isnormal.Excessivedrainageindicatesyourworkshopcompressorrequiresdrainingand/orafiltersystemofitsown.FailuretokeepworkshopcompressordrycanresultincontaminationoftheSMT300testerandvehiclebeingtested.

SAEINTERNATIONALpublishedpapersstronglyrecommendyouconnectthesmokemachinetoaninertgas,suchasnitrogenorCO2,whentestingavehicle’sfuelvapor(EVAP)systemduetoitspotentiallyexplosivefumes.

Page 9: SMT 300 Smoke Machine Tester Operator ManualSMT 300 Universal Filler Neck Adapter (F00E900362) Allows direct connect of the SMT 300 smoke output hose to most fuel tank filler necks

SMT 300 Operator Manual | Version 1 | January 2011 Robert Bosch LLC

SMT 300 Operator Manual | Basic Testing Procedure | 7

Basic Testing Procedure

1. ConnecttheSMT300testertoworkshopair.

2. ConnecttheSMT300tester’sredpowercabletovehicle’s12VoltDCbatterypositiveterminal.

� Batterymustbeingoodconditionandfullycharged!

3. ConnecttheSMT300tester’sblackcabletothevehicle’schassisground.DoNOTconnecttheblackcabletobatterygroundbecauseasparkinthevicinityofthebatterycancauseanexplosion!(Figure 1)

4. ObservethatthegreenpowerindicatorlampontheSMT300testeris‘ON’confirmingthatyouareproperlyconnected.

� Ablinkinggreenpowerlampindicatesinsufficientbatterypowertothetester.

5. Connectsmokesupplyhosetosystembeingtested.

� FlowControlValvemustbeinfullOpen(+)position.(Figure 2)

6. Press<ON>buttonandfillsystemwithsmoke.

� Smokeproductionison5-minutetimer.

7. Usewhitelightsuppliedandlookforexitingsmokeoruseultravioletlightsuppliedtolookforfluorescentdyedepositatexactlocationofaleak.

� Thelongersmokeisallowedtoexitaleak,themorefluorescentdyewillbedepositedatleaklocations.

� Wheneverpossibleitisbestto‘purge’the‘non-smoke’airoutofthesystembeingtestedinordertoquicklyfillthesystemwithsmoke.

Optional Gas SourceShown here using the optional portable Inert Gas Pack. (PartNo.F00E900355)

ThisgaspackmakestheSMT300testerveryportableandisalsoperfectforsaferEVAPtesting,sincethegassuppliedisinert.One20oz.cylinderwillperformabout25fullcycletestsandisinexpensivetorefill.PleaseNote:ThisInertGasPackisshippedwithanemptygascylinder(forsafetyreasons).Priortousingforthefirsttime,thecylindermustbefilledwithliquidCO2.ContactalocalrefillingstationforliquidCO2.Suggestion:ForCO2, contactalocalairtoolorsportinggoodsrefillinglocation(i.e.hardwarestore,sportinggoodsstore,orpaintballsupplyhouse)

Black to chassis ground

Figure1

Figure2

Page 10: SMT 300 Smoke Machine Tester Operator ManualSMT 300 Universal Filler Neck Adapter (F00E900362) Allows direct connect of the SMT 300 smoke output hose to most fuel tank filler necks

Robert Bosch LLC SMT 300 Operator Manual | Version 1 | January 2011

8 | Flow Meter Overview | SMT 300 Operator Manual

Flow Meter Overview

Flow

Aflowmeterballindicatingflowmeansthereisflowgoinginto(orthrough)thesystembeingleak-tested.Thisisnormalwhilethesystembeingleaktestedisbeingfilled.

� AnEVAPsystemwillusuallytakeabouttwominutestofill.

� Anindicationofthesystembeingfulliswhentheflowmeterballstopsdescendingduringtheleaktest(orwhenthepressuregaugestopsincreasinginpressure).

Iftheflowmeterballdescendstothebottomoftheflowmeter;thatindicatesthereisnoflowthroughthesystembeingtested,orthatthereisnoleakinthesystembeingleaktested.

Iftheflowmetercontinuestoindicateflowafterthesystemisfilled,thisindicatesaleak.Thehighertheballisintheflowmeter,thelargertheleaksize.

EVAP Leak Size Reference Points

Theflowmeterhastwoleaksizereferencepointswhichhelpquantifytheleaksizeinthesystembeingleaktested.The.020”(0.5mm)and.040”(1.0mm)referencepointsareequivalenttoleaksofthosesizesintheEVAPsystembeingtested.

Oncethesystemisfilled(eitherinTESTorSMOKEsetting)andtheflowmeterballstopsdescending;positiontheflowmeter’sredflagsothatitalignswiththeleveloftheflowmeterball.ComparetheleveloftheballwiththereferencepointsinordertodetermineaPASS/FAIL.

AballreadingabovethereferencepointindicatesaFAIL.

AballreadingbelowthereferencepointindicatesaPASS.

NOTE:TheflowmeterismostaccuratewhentheSMT300controlvalveisinTEST(non-smoke)setting.

Remember:Alltestswiththistesterareperformedwiththevehicle’sengineturnedoff!

Leak Size Reference Points

Flow Meter Ball

Page 11: SMT 300 Smoke Machine Tester Operator ManualSMT 300 Universal Filler Neck Adapter (F00E900362) Allows direct connect of the SMT 300 smoke output hose to most fuel tank filler necks

SMT 300 Operator Manual | Version 1 | January 2011 Robert Bosch LLC

SMT 300 Operator Manual | EVAP Tech Tip | 9

EVAP Tech Tip

NOTE: TheflowmeterisactiveinallsettingsoftheFlowControlValve.However,forthemostprecisequantifyingofaleaksizeusetheTESTsettingineitherofthesetwomethods:

A. FillsysteminTEST(nosmoke)settinguntilflowmeterballstopsdescending.Positiontheflowmeter’sredflagsothatitalignswiththeflowmeterballposition(asdescribedonpreviouspage).Compareflowmeterballpositionwithflowmeter’sLeakSizeReferencePoints.Iftheleaksizeisunacceptable(abovereferencepoint)andleaktestingisrequired;setcontrolvalvetoSMOKEsetting,introducesmokeandlookforsmokeordyetofindtheleak(s).

Or

B. Tosavetime;fillsysteminSMOKEsetting(fullopen).BesureTesterisstill<ON>andwhentheflowmeterballstopsdescending,immediatelypositionthecontrolvalvetoTESTandallowtheballtosettle(TESTsettingwillgiveyouamoreaccurateflowmeterreading).Compareflowmeterballpositionwithflowmeter’sLeakSizeReferencePoints.

� Abovereferencepoint=FAIL.

� Below referencepoint=PASS.

Iftheleaksizeisunacceptableandleaktestingisrequired,thentimewillhavebeensavedbecausethesystemisalreadyfilledwithsmoke.NowpositionthecontrolvalveagaintoSMOKEandcontinuetointroducesmokewhilelookingforsmokeordyeatleakexitpoints.

NOTE: Whensmoketestingaclosedsystem,suchastheEVAPsystem;itisbesttopurgethe‘non-smoke’airoutofthesystembyleavinganopeninginthesystembeingfilledwithsmoke(e.g.EVAPvent).Closethesystemoncesmokeexitsandcontinuetofillwithsmoke.Thisquicklyfillsthesystemwithsmoke.

Page 12: SMT 300 Smoke Machine Tester Operator ManualSMT 300 Universal Filler Neck Adapter (F00E900362) Allows direct connect of the SMT 300 smoke output hose to most fuel tank filler necks

Robert Bosch LLC SMT 300 Operator Manual | Version 1 | January 2011

10 | Control Valve Overview | SMT 300 Operator Manual

Control Valve Overview

TEST (non-smoke)settingdeliversnon-smokeairandthemostaccurateflowmeterreading.ThisistheperfectsettingwhenyouwantthemostaccurateleaksizereadingwhentestingtheEVAPsystem.

Thissettingcanalsobeusedwhentestingmanysystems,suchasasolenoidfunction,whensmokeisnotneeded.Testthesolenoidwhileactivatingitopenandclosed.Closingthesolenoidshouldmaketheflowmeterballdroptothebottom.Aflowmeterindicatingflow,whilethesolenoidisclosed,confirmsaleakinthesolenoid.

SMOKE (fullopen)settingdeliversmaximumsmokevolumetothesystembeingleaktested.

FLOW CONTROL controlssmokevolume.Locatingtheleaksourceissometimeseveneasierwithlesssmokevolumeexitingaleak.AfterfillingasystemwithsmokeintheSMOKE(fullopen)setting,usethesmokevolumecontrolknobtotuneinthedesiredvolumeofsmokeexitingaleak.

NOTE: FlowControldoesnotaffectdeliverypressure;itonlyaffectssmokeflowvolume.

Page 13: SMT 300 Smoke Machine Tester Operator ManualSMT 300 Universal Filler Neck Adapter (F00E900362) Allows direct connect of the SMT 300 smoke output hose to most fuel tank filler necks

SMT 300 Operator Manual | Version 1 | January 2011 Robert Bosch LLC

SMT 300 Operator Manual | Sample Leak Detections | 11

Sample Leak Detection ApplicationsThisleakdetectorcanbeusedinvirtuallyanyvehiclelowpressuresystemsuspectedofhavingaleak,suchas;EVAPsystem,intake/inductionsystem,intercoolerandturbochargersystem,vacuumsystem,exhaustsystem,wind/waterleaksandcanalsobeusedtoverifyairsolenoidfunctionsandtestcomponentspriortoassembly.FordetailsonEVAPtesting,pleaserefertotheBoschtrainingmaterials(notincludedwiththismanual).

Intake/Induction Leaks

Exhaust Leaks

Page 14: SMT 300 Smoke Machine Tester Operator ManualSMT 300 Universal Filler Neck Adapter (F00E900362) Allows direct connect of the SMT 300 smoke output hose to most fuel tank filler necks

Robert Bosch LLC SMT 300 Operator Manual | Version 1 | January 2011

12 | Sample Leak Detections | SMT 300 Operator Manual

Wind and Water leaks

1. Setvehicle’sclimatecontrolto‘freshair’andsetbloweronfullspeed.

� Thiscreatespositivecabinpressure.

2. ConnecttheSMT300tester’ssupplyhosenozzletoSmokeDiffuser.

3. Laysmokepathalongseals.

4. Lookforsmokedisturbanceindicatingaleak.

� Noairdisturbancemeans‘NoLeak’.

Airdisturbancepinpointstheleak.

Page 15: SMT 300 Smoke Machine Tester Operator ManualSMT 300 Universal Filler Neck Adapter (F00E900362) Allows direct connect of the SMT 300 smoke output hose to most fuel tank filler necks

SMT 300 Operator Manual | Version 1 | January 2011 Robert Bosch LLC

SMT 300 Operator Manual | Sample Leak Detections | 13

Sample UV deposits

Thepatentedsmokevaporcontainsaspecialultraviolet-activatedfluorescentdyethatgetsdepositedattheexactlocationofaleak.UsetheUVlightprovidedtohighlightthedye.

� Thistechnologyisdesignedsothatthedyewillonlydepositifthereispressure-differential.Soforinstance,thedyewilldepositwhenexitingaleakbutwillnotdepositduringthewindandwatertest.

� Thelongerthesmokeisallowedtoexitaleak,themoredyewillbedeposited.

Page 16: SMT 300 Smoke Machine Tester Operator ManualSMT 300 Universal Filler Neck Adapter (F00E900362) Allows direct connect of the SMT 300 smoke output hose to most fuel tank filler necks

Robert Bosch LLC SMT 300 Operator Manual | Version 1 | January 2011

14 | Troubleshooting | SMT 300 Operator Manual

Troubleshooting Guide

Green Red Interval Cause

✔ ConstantON Goodbatterypower.

✔ Blinks:1-persecond Insufficientbatterypower.

✔ ✔ Blinkssimultaneously:1-persecond Badgroundatsmokecanisterorcircuitboard;orpowerconnectionatbatteryisloose;orshortinheatingcircuit.

✔ ✔ Blinkssimultaneously:4-persecond Badgroundatsmokecanisterorcircuitboard;oropenheatingcircuit.

✔ ✔ Blinksalternately:1-persecond (Systemwillshutdown.Powermustbedisconnected/connected.)

Badgroundatsmokecanisterorcircuitboard;orcircuitboardfailure.*

* Ifcircuitboardfailureoccurs,firsttrydisconnectingpowertotheSMT300testerfor10secondsandreconnect.Iffailurecodeoccursasecondtime,disconnecttheSMT300testerandcontactthemanufacturer.

Symptom Likely Cause Solution

1. ThegreenpowerindicatorlampontheSMT300testerdoesnotturnON.

1. Thepowercablesarereversed.

2. Poorpower-supplycableconnection.

3. Batteryprovidingpoweristooweak.

1. Correctlypositionthepowercables.

2. Securetheconnectionatthepositiveterminalandchassisground.

3. Verifythebatteryisingoodconditionandfullycharged.

2. IturntheSMT300testerONbutthereisnoairorsmokecomingoutofthesupplyhose.

1. Poorpower-supplycableconnection.

2. Batteryprovidingpoweristooweak.

3. Airsupplytotesterisinsufficient.

1. Securetheconnectionatthepositiveterminalandchassisground.

2. Verifythebatteryisingoodconditionandfullycharged.

3. Besureair/nitrogensupplyissufficient.

2. Verylittlesmokecomingoutofthesmokehoseorthereisoildrippingfromthesmokehose.

1. Thereistoomuchsmokecondensationinsidethesmokesupplyhose.

�ThesmokevaporfromtheSMT300isverydenseanditisnormalifattimesitcondensesinsidethehose.Thisusuallydoesnotindicateaproblem.

1. PositionthehoselowerthantheTester.SetcontrolvalvetoTESTandturnTester<ON>foronecycle,oruntiloilhasdrainedfromhose.

SMT 300 Technical Service Line

(866)670-7734MondaythruFriday8:00amto4:00pmPST(PacificTime)

Page 17: SMT 300 Smoke Machine Tester Operator ManualSMT 300 Universal Filler Neck Adapter (F00E900362) Allows direct connect of the SMT 300 smoke output hose to most fuel tank filler necks

SMT 300 Operator Manual | Version 1 | January 2011 Robert Bosch LLC

SMT 300 Operator Manual | Warranty | 15

SMT 300 Warranty

LIMITEDONE(1)YEARWARRANTY

OriginalPurchaserWarranty:undernormaluse,careandservice,theSMT300(exceptasotherwiseprovidedherein)shallbefreefromdefectsinmaterialandworkmanshipforONE(1)YEARfromthedateoforiginalinvoice.

Seller’sobligationsunderthiswarrantyarelimitedsolelytotherepairor,atSeller’soption,replacementoforrefundoftheoriginalpurchasepricefor,SMT300orpartswhichtoSeller’ssatisfactionaredeterminedtobedefectiveandwhicharenecessary,inSeller’sjudgment,toreturntheequipmenttogoodoperatingcondition.

RepairsorreplacementsqualifyingunderthisWarrantywillbeperformedormadeonregularbusinessdaysduringSeller’snormalworkinghourswithinareasonabletimefollowingBuyer’srequest.Allrequestsforwarrantyservicemustbemadeduringthestatedwarrantyperiod.

Page 18: SMT 300 Smoke Machine Tester Operator ManualSMT 300 Universal Filler Neck Adapter (F00E900362) Allows direct connect of the SMT 300 smoke output hose to most fuel tank filler necks

Robert Bosch LLC SMT 300 Operator Manual | Version 1 | January 2011

16 | Notes | SMT 300 Operator Manual

Page 19: SMT 300 Smoke Machine Tester Operator ManualSMT 300 Universal Filler Neck Adapter (F00E900362) Allows direct connect of the SMT 300 smoke output hose to most fuel tank filler necks

SMT 300 Operator Manual | Version 1 | January 2011 Robert Bosch LLC

SMT 300 Operator Manual | Notes | 17

Page 20: SMT 300 Smoke Machine Tester Operator ManualSMT 300 Universal Filler Neck Adapter (F00E900362) Allows direct connect of the SMT 300 smoke output hose to most fuel tank filler necks

Robert Bosch LLCAutomotiveAftermarketDivisionDiagnosticsBusinessUnit2040AlamedaPadreSerra,Ste220 SantaBarbara,CA93103 TollFree:800-321-4889Fax:805-966-9540www.boschdiagnostics.com

BOSCH is a trademark licensed by Robert Bosch GmbH and/or its affiliated entities. © 2011 Robert Bosch LLC, USA. All rights reserved.