Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Upload: monica-griffith

Post on 27-Dec-2015

232 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1

Smile Controller Family

Page 2: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 2

• There are controllers from 3 to 12 relays• applications cover heating, district heating,• all controllers have proprietary communication• controllers have 4 language menues• DIN housing

Features

Page 3: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 3

• spring terminals in wall socket• backlit 3 line display• push and turn operation with softkeys• standard wall module and wall module for individual access• service interface on controller front• several applications in one „box“

Features Highlights

Page 4: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 4

Information key

Heating characteristics

Operating mode key forPermanent and temp. modes

Manual mode key

Multi-functional Display

Rotary Pushbuttom

Cover clip for service jack

Daytime room temp

Nighttime room temp

DHW daytime temp

User Interface

Page 5: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 5

C = Central Area, E = Eastern Europe ...p = panel mount w = wallmount1x..4x = heating, 5x = district heating, 6x = ventilation, 7x= boiler cascade, 8x = solar

1 = number of analog outputs*3, 8 = number of relaysSmile = controller family (smile digital contr.)

Type key

SDC 9 x-21 P C

* is only mentioned when there is an analog output. For example SDC 41-61 PC

District heating only:DHC 43 - 1 PC / WC (7 Relais)DHC 43 - 2 PC / WC (9 Relais)

Controller Types

Page 6: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 6

C = Central Area: D, GB, F, I

Language versions

Page 7: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 7

Easy system architecture:

Max 5 controllers per systemMax 3 wall modules per controller

Architecture

Page 8: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 8

System architekture (max size)

MK 2

MK 1

DK

MK 2

MK 1

DK

MK 2

MK 1

DK

MK 2

MK 1

DK

MK 2

MK 1

DK

Architecture

Page 9: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 9

Displaytest at power on

- 21 x 14 –segments characters- 16 symbols- timescale divided in 30 min segments. - 13 hour marks

°CKWhmin%qqqqq qqqq

°CKWhmin%

0 4 6 82 10 12 14 16 18 20 22 24

qqqqqqqqqqqqI II

the 14 segment characters can show also kyrilic and hebrew letters

Display

Page 10: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 10

Push and turn knob

Operation

2

3

1

The centrally positioned push and turn knob has several functions:Turning clockwise will change to highervalues and vice versaA short push will confirm the settingA long push (appr. 3 secs) will a)start the parameter menueb)go back to the previous input level

Page 11: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 11

User hierarchy

entering the installer or OEM code will enable additional parameters for adjustmentPlease press and at the same time and hold

Enter the code by turning and pushing the knob for confirmation for each number separately.

The installer code default is 1234

Parameter input

Page 12: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 12

Operating keys

Day room setpoint

Night (reduced)room setpoint

Operation

This key enters the desired room setpoint for automatic operation and the operation modes „heating“ and „party“. In the standard functionthis is the setpoint for all heating circuits of the controller

This key enters the desired reduced room setpoint for automatic operation and the operation modes „absent“ and „reduced“. In the standard functionthis is the setpoint for all heating circuits of the controller

Page 13: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 13

c

Operation

Operating keys

Warm water day setpoint

Operating mode key

This key enters the desired warm water setpoint for automatic operation and the operation modes „heating“ and „party“ and „summer“.

This key enters the desired operating mode. A cursor will show at the bottom of the display in combination with an explanatory text in the first line. In the standard function the operation mode is valid for the whole controller The same key serves as escape key i.o. to return to the standard display

Page 14: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 14

Heating curve

Operation, heating curve

Operating keys

This key enters the desired heating curve for all circuits in the controller. Adjustment range: 0,20...3,5Default: unmixed heating circuit:=1,50

mixed heating circuit:=1,00 Returning to the basic display is either possible by pressing this key twice or waiting for 60 seconds

Page 15: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 15

Operation, status info

With this info key the user can displayvarious status information about inputs andoutputs.The info is always starting with the outdoor temperature. By turning the knob clockwiseall activated information can be reached.Setpoint can be displayed by pressing the knob.

When entering a value this key can also be used

to move the cursor one position back.

System information

Operating keys

Page 16: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 16

Manual Operation Operating keys, district heatingManual key

Pressing this key longer than 5 sec. will switch the controller into manual mode.Here the heat generator setpoint can be adjusted with the knob. All pumps will be running, while vales can only be operated by moving either the motor or the valve by hand.The heatgenerator setpoint is adjustable between 5..80°C. The setpoint is displayed as well as the actual temperature.

The switching differential is according to the parameter And is symmetrical to the setpoint.

Page 17: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 17

Manual Operation

Operating keys, heatingManual key, emission test

In addition to the described manual function, this keycan be used to start the emission test phase for theservice man.With a short push of this button the boiler will operatewith it´s adjusted max. temperature limit for a periodeof 20 minutes.The remaining time will be displayed.

By pushing and holding the key the controller will ignore the max. limit and the temperature an reach a higher value in order to test the safety limiter.

Page 18: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 18

Cold start

By pressing and holding all 4 keys at the same time a cold start is carried out. (return to default settings)This cold start will only effect the parameters of the activated operating hierarchy.The date/time setting and all switching programmes are effected also

Variable cold start

Page 19: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 19

1. Check controller wiring2. Switch on power after segmenttest a similar line will appear:

26.06 V.1.00 date und version of software .

3. Please check if weekday, date, month and actual time are ok . If not please adjust in appropriate parameter menue. (controller will be delivered with running clock)

4. Please press the keys and at the same time and hold until CODE appears in the top line Enter installer code 1 2 3 4 with push and turn knob The display will switch to the standard picture after about 2 sek.

5. Hold push and turn knob until the menue switching times will appear and turn the knob clockwise until the menue hydraulic appears. Confirm by pushing, then parameter 01 will show 0000

6. Enter system hydraulic number, e.g. 0201 , or individual hydraulic parameters.

First start up

Page 20: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 20

Decisions before start up:

Do I treat all heatconsumers as one?(Then: System/operation mode=1)Do I use only one time program per consumer?(Then: system/ program = P1)Do I treat heatconsumers individually?(Then: System/operation mode=2)Do I want different time programs for individual heatconsumers?(Then: System/operation mode=2 and system/program=P1-P3)

Start up

Page 21: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 21

Operation mode= 1: Equal day-night setpoints and operation mode for all heating circuits

Operation mode= 2: individual day-night setpoints and operation modes for all heating circuits

Operation modes

Menue:System/Operation

Page 22: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 22

Time program DK MK 1 MK 2 WW ZirkP 1 P1 individually adjustable for each consumer

Time program DK MK 1 MK 2 WW ZirkP1..3 P1 + P2 + P3 individually adjustable for each

consumer

Time programs

Menue: System/time programs

Page 23: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 23

Time programs

Timeprograms, default values

Timeprogram P1 Timeprogram P1...P3

Page 24: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 24

Overview Controller TypesH

oney

wel

l typ

e pr

opos

al

Num

ber

of s

tand

ard

rela

ys +

var

iabl

e ou

tput

s

2nd

stag

e or

DH

-va

lve

clos

e

1st

stag

e or

DH

-va

lve

open

unm

ixed

/ va

riab

le

outp

ut 3

mix

ing

circ

uit

1

mix

ing

circ

uit

2

DH

W lo

adin

g pu

mp

var

iabl

e ou

tput

2

SDC3-10 3-Rel. x x xSDC3-40 3-Rel. xSDC6-20 6-Rel. x x x xSDC7-21 7-Rel. x x x x xSDC8-21 6-Rel.+ 2 Variable x x x x xSDC9-21 7-Rel.+ 2 Variable x x x x x x

SDC12-31 10-Rel.+ 2 Variable x x x x x x xDHC 43-1 7-Rel x x x x xDHC 43-2 7-Rel.+ 2 Variable x x x x x x

Each Controller is available for Panel Mount (PC) or for Wall Mount (WC)

Page 25: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 25

Mounting - Panel mount

Panel mountwith 4 terminalrows at the back of the controller

Page 26: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 26

Mounting – Wall mount

Wall mountwith screwsor on DIN rail

Page 27: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 27

10= standard room unit 20=comfort room unitSmile = controller family

Type key

SDW 20

SDW20

Room Units

SDW 10

Page 28: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 28

Application Codes

0901, ...Special Applications

0801, 0802, ....Solar Applications

0701, 0702, ....Bolier Sequence

0601, 0602, ....Ventilation Applications

0501, 0502, ....District Heating Applications

0401, ....Additional Heating Circuits

0301, 0302, ....Basic Applications with 3 Heating Circuits

0201, 0202, ....Basic Applications with 2 Heating Circuits

0101, ....Basic Applikations with 1 Heating Circuit

Page 29: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 29

Heating Hydraulic 0101 SDC 12-31SDC 9-21SDC 8-21SDC 7-21SDC 6-20SDC 3-10- 1 stage burner- unmixed heating circuit- DHW

Page 30: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 30

Heating Hydraulic 0201 SDC 12-31SDC 9-21SDC 8-21SDC 7-21SDC 6-20- 1 stage burner- unmixed heating circuit- mixed heating circuit- DHW

Page 31: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 31

Heating Hydraulic 0202 SDC 12-31SDC 9-21SDC 7-21- 2 stage burner- unmixed heating circuit- mixed heating circuit- DHW

Page 32: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 32

Heating Hydraulic 0301 SDC 12-31- 1 stage burner- unmixed heating circuit- 2 mixed heating circuits- DHW

Page 33: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 33

Heating Hydraulic 0302 SDC 12-31- 2 stage burner- unmixed heating circuit- 2 mixed heating circuits- DHW

Page 34: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 34

Heating Hydraulic 0401 SDC 12-31SDC 9-21SDC 8-21SDC 7-21SDC 6-20SDC 3-40- 1 mixed heating circuit

Page 35: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 35

District Heating Hydraulic 0501 DHC 43-2DHC 43-1- District Heating Valve- unmixed heating circuit

Page 36: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 36

District Heating Hydraulic 0502 DHC 43-2DHC 43-1- District Heating Valve- unmixed heating circuit- DHW

Page 37: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 37

District Heating Hydraulic 0503 DHC 43-2DHC 43-1- District Heating Valve- unmixed heating circuit- separate DHW control

/////// //

STB W F

///

VFB

//////

////

V 1

P 1

P 4

P 3//AF

//

SF

0503

.cdr

Page 38: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 38

District Heating Hydraulic 0504 DHC43-2- District Heating Valve- unmixed heating circuit- layered DHW storage tank

Page 39: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 39

District Heating Hydraulic 0505 DHC 43-2DHC 43-1- District Heating Valve- mixed heating circuit

Page 40: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 40

District Heating Hydraulic 0506DHC 43-2DHC 43-1- District Heating Valve- unmixed heating circuit- mixed heating circuit

Page 41: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 41

District Heating Hydraulic 0507 DHC 43-2DHC43-1- District Heating Valve- mixed heating circuit- DHW

Page 42: Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 1 Smile Controller Family

Smile training

Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, 2002 42

District Heating Hydraulic 0508 DHC43-2- District Heating Valve- unmixed heating circuit- mixed heating circuit- DHW