smartmax io board ma – 4020 - maxon solutions

2
Turn your Smartmax M2M HSPA Smart Modem Solution into a cost-effective mini RTU with the I/O Interface Controller. When used in conjunction with Maxon’s Smartmax Modem for data telemetry, the I/O Interface Controller provides wide-ranging flexibility for system integrators and users for automating and controlling innumerable field applications. Local or remote programming of the I/O Interface Controller can be done via the Smartmax’s built-in Web Interface. The fully featured web interface includes programming of the DNP3 settings and I/O status updates via SMS. The SmartMax connects directly to the IO board via a ribbon connection, while the I/O controller can be wired to collect data automatically and connect directly to sensors, meters, loggers or process equipment. The Smartmax coupled with the I/O Interface Controller Board is the ultimate low cost data logging solution. 170908 TRANSFORM THE SMARTMAX INTO A POWERFUL COST-EFFECTIVE MINI REMOTE TERMINAL UNIT Smartmax I/O Board Features 6 Digital Inputs (1 configurable as pulse input) 2 Analogue Inputs 4 Digital Outputs 1 Pulse Input DNP3/SMS Settings configurable via web page inside Smartmax Modem. I/O Board controllable via DNP3, SMS, or using inbuilt web page. SDK (Software Development Kit) is available for the Smartmax HSPA Modem (Product Code: MA-2010) * Not to scale CHOOSE WELL... CHOOSE WISELY... CHOOSE MAXON... M2M HSPA Smart Modem Solution - I/O Board: MA-4020

Upload: maxon-data-communications

Post on 27-Jun-2015

73 views

Category:

Technology


2 download

DESCRIPTION

You can transform the Smartmax M2M HSPA smart modem into a cost effective mini RTU having an I/O interface controller. The modem can be used in conjunction with other compatible Maxon Smartmax modems for data telemetry purposes. The I/O interface controller provides wide ranging flexibility for integration with various system devices and automation processes required for controlling and monitoring varied field application systems and devices. Local as well as remote programming of the I/O interface controller can be carried out via a built-in web interface. The feature rich web interface application facilitates the programming of DNP3 settings and also supports I/O status updates via SMS utilities. The modem connects directly to the IO board through a ribbon connector, and the I/O controller can be set up or wired to collect data automatically. Connect directly to a host of Remote Terminal Units (RTUs), Intelligent Electronic Devices (IEDs), sensors, meters, loggers, and process equipment. The Smartmax M2M HSPA smart modem when used in conjunction with the I/O interface controller board offers ultimate cost effective data logging and device monitoring solutions.

TRANSCRIPT

Page 1: Smartmax IO Board MA – 4020 - Maxon Solutions

Turn your Smartmax M2M HSPA Smart Modem Solution into a cost-effective mini RTU with the I/O Interface Controller. When used in conjunction with Maxon’s Smartmax Modem for data

telemetry, the I/O Interface Controller provides wide-ranging flexibility for system integrators and users for automating and controlling innumerable field applications.

Local or remote programming of the I/O Interface Controller can be done via the Smartmax’s built-in Web Interface. The fully featured web interface includes programming of the DNP3

settings and I/O status updates via SMS.

The SmartMax connects directly to the IO board via a ribbon connection, while the I/O controller can be wired to collect data automatically and connect directly to sensors, meters,

loggers or process equipment.

The Smartmax coupled with the I/O Interface Controller Board is the ultimate low cost data logging solution.

1709

08

TRANSFORM THE SMARTMAX INTO A POWERFUL COST-EFFECTIVE MINI REMOTE TERMINAL UNIT

Smartmax I/O Board Features• 6DigitalInputs(1configurableaspulseinput)

• 2AnalogueInputs

• 4DigitalOutputs

• 1PulseInput • DNP3/SMSSettingsconfigurableviawebpage inside Smartmax Modem.

• I/OBoardcontrollableviaDNP3,SMS,orusing inbuilt web page. • SDK(SoftwareDevelopmentKit)isavailableforthe Smartmax HSPA Modem (ProductCode:MA-2010)

* Not t

o scale

CHOOSE WELL... CHOOSE WISELY... CHOOSE MAXON...

M2M HSPA Smart Modem Solution - I/O Board: MA-4020

Page 2: Smartmax IO Board MA – 4020 - Maxon Solutions

www.maxon.com.au

Metering

Water

Road Signs

Power

Security

Transport

M2M HSPA Smart Modem Solution - I/O Board: MA-4020

T | +612 8707 3000 ● F | +612 8707 3001 ● E | [email protected] ● 36A Gibson Avenue, Padstow NSW Australia 2211 ● www.maxon.com.au

Environmental Specifications• NormalOperationTemperature-20to60°C

• ExtremeOperationTemperature-25to75°C

Connections• 6xDigitalInputs(INPUT0~INPUT5interminalblock)

• 4xDigitalOutputs(OUTPUT0~OUTPUT3interminalblock)

• 2xAnalogInputs(ANALOG0andANALOG1)

• 1xPulseInput(INPUT0)

• 1xCaseOpen

• 1xBattery(MonitorBatteryLevel)

• 1x20PinTerminalBlock(SmartMaxInterface)

Compliance• RoHSCompliant

Frequency Bands•WCDMA/HSPA850MHz,900MHz,1900MHz,2100MHz

•GSM/GPRS/EDGE850MHz,900MHz,1800MHzand1900MHz

GeneralFeatures• PacketData

• 2WaySMS

• RemoteSMSdiagnostics&reset

• EmbeddedTCP/IP,UDP/IPSTACK

• In-builtperiodicreset

• ExternalDCPowered

• SupportVPNServerandClientMode

• DynamicDNS

• SupportsDNP3(Outstation)usingextensionI/Oboard

• RuggedMetalCasingforindustrialuse

• In-BuiltWebInterface

• ProgrammableschedulertocontrolWANconnection

• Telnetsupport

• Saveandrestoremodemconfigurationfromafile

• FOTA-Firmwareupgradeovertheair

• ExternalantennaconnectivitytomaximiseHSPA coverage

• ExternalLEDtoshowNetworkandConnectionstatus

Dimensions• 210mmX1100mmX650mm(withconnectors)

A mini usb cable is required for first time purchasers of the Smartmax, as most of the programming can only be done via the web interface. This is available in the Smartmax Complete Package (MA-2010C), the Smart-max SDK (MA-7000), and separately. Speak to your Maxon Account

Manager for more information.

Connection Specifications6DigitalInputsCharacteristics

· VIH(Inputvoltagehighrange):2~24V

· VIL(Inputvoltagelowrange):-2~0.8V

· Ri(Inputimpedance):morethan5kΩ

· Rd(Internalpull-up):47kΩforshorttogrounddetection

· Input chatters are filtered by S/W setting

1 Pulse at Input 0

· Frequencyrange0~1000Hz

· Accuracy(25°C)0.05%ofspan

· Temperaturestability 0.005%/°C

· Inputimpedance47kΩ

 

4DigitalOutputs

· MOSFET switch to ground

· Ro(Outputresistance):lessthan300mΩ

· VOpen(maximumallowedoutputvoltageonopen):24VDC

· IOut(maximumallowedswitchingcurrenttoground):1A

· Switching time < 10 msec

· Chatter free

 

2 Analog Inputs

· 12bit resolution

· Accuracy:Typical±0.25%;WorstCase ±1%

· Maximumsamplingrate:10sample/sec

· Inputsignaltype:oneof0~20mA,0~5V,or0~10V

· (Theinputtypeisselectedbythejumper“PULSE”onthe connectedSmartmaxandINPUT#ontheI/Oboard)

· Inputimpedanceforthesignaltype0~20mA<100Ω

· Inputimpedanceforthesignaltype0~10VDC>10KΩ