  • 7/28/2019 SmartBus G4 Logic2 (Data Sheet)

    1/2

    SB-LOGIC2-DNAutomation Logic and central clock

    Time ClockBuilt in time clock with centralBroadcast function.DTS day time adjustmentMuslim 5 Prayer Times functionaccording to city Long and Lat.

    Logic LinesTotal 960 logic lines: 240 Ta-bles, each 4 Logic lines.

    Logic CommandsSimplified logic commands like:(if, or, nand, nor +255 Flags)

    Control IO3 x Advanced RS485 S-BUSserial port links (both train &screw link types)

    Upgrade IO1 x mini USB port (to connect tospecial programming board)

    User Controls LED status indicator/channel Diagnostic LED+ BROADCAST

    ProgrammingAdvanced Software Configu-ration & Programming

    ComplianceCE Mark EMC

    Operation Protection BUS Rv. Polarity Protection BUS Short Circuit Protection

    Trigger ConditionsLogical trigger or commandconditions consist of trigger

    combinations like: time, sceneLight channel status, curtainstatus, room temperature, se-curity mode, day, night,flag...etc.

    SBUS DC Supply24VDC with flexible tolerancebetween 8-32VDC. Flexibleability to add power supply asto be needed any wherePower consumption: 15mA

    Installation 35mm DIN-Rail Mount Ready Wall Mount Ready (4P)

    Operating Environment0 to 45C ambient temperature20% to 93% RH

    Enclosure & SizePolycarbonate, DIN-rail (4 Unit)Dimensions &WeightW 91mm x L 73mm x H 75mmPacked weight 0.22 kg

    lights Moods Media Curtains SecurityMusic SMS Pumps Access Scenes

    Temperature Announcement FAN Genset

    GTIN (UPC-EAN): 0610696254054Patent P. No: 201110123081.0

    DIN-Rail Mount , Central Time Clock and Main Automation Cont roller. It is the smart system servant that assist andmoni tor temperature, events, energy consumption, patterns, with main Targets: maintain, safeguard, protect andeconomize. It Can Trigger prayer announcements, reminders, alerts, macros, and moods. Each Logic module Con-sist of 240 tables, Each Table of 4 programmable Logic Lines totaling up to 960 Line of Logics using simplif ied

    (and, Or Nand, Nor, with 255 Flags). logical condi tion consist of trigger combinations like: time, scene Light chan-nel status, curtain status, room temperature, security mode, day night, time... and so on**Added function: Improved Logic Table Configuration and Viewing of used against available flags.

  • 7/28/2019 SmartBus G4 Logic2 (Data Sheet)

    2/2

    SB-LOGIC2-DNAutomation Logic and central clock

    Specifications subject to change without notice. Smarthome -Group Trading as Smart-

    BUS. Texas 77043 - USA. All rights reserved. Smart Mesh , Smarthome BUS and all other

    associated logos are the registered trademarks of Smart-Group . Not to be used nor repro-

    duced without written permission. All Patents and IPOs Remain owned by SmartHome Group

    SB-G4 Data Sheet Rev 1.0 released Sept 2011

    www.smarthomebus.com [email protected]

    USA - Germany - Denmark - Hong Kong - Jordan - China - UAE

    S.BUS Connector

    CAT5e UTP Cable

    +24V D+D-GND

    S.BUS +24V

    S.BUS GND

    S.BUS D+

    S.BUS D-

    Spare

    Spare

    Spare +12v

    Spare -12V

    orange

    w/orange

    blue

    w/blue

    green

    w/green

    brown

    W/brown

    ELEVATION

    SIDE VIEWPROSPECTIVE Copper 98%