Smart Home Alarm System User Manual
When designing, this system be added many amazing & practical new features, to make sure a better smart life.
Main Features :
■ 99 defense zones and 6 zone types of each ■ Stress alarm & tamper alarm & anti-‐false alarm &
anti-‐jamming ■ Built-‐in Temperature scope alarm & Knock-‐over alarm ■ Door-‐open alert ( two-‐way door contact for optional ) ■ 60 arm/disarm/alarm records obtained ■ LCD program menu / Touch keypad & Voice prompt ■ 5 international languages available ( extended up to 7 languages ) ■ Pairing status obtained &Sensors real-‐time power volume obtained ■ SMS alert for any 16 zones / 10 remotes be renamed ■ 12 seconds voice message for alert & 12 seconds voice Memo ■ Low-‐voltage alert for panel & accessories ■ 6 phone numbers for alarm calls/SMS alert ■ Breathing LED light for Out arm/Home arm status ■ All settings via Keypad/SMS/Phone call ■ 6 timers for arm/disarm ■ SMS alert for extra power on/off ■ Direct phone call as normal phone ■ Etc…
Quick Installation 1. Insert a SIM card into the panel ; make sure the SIM card is valid,and
PIN code be deactivated when have ;
2. Switch on the panel, the icon of SIM card will flash a while to search gsm network. when the icon doesn’t flash ,then gsm network be searched out ;
3. Input Program password ( 123123) +Menu button ,Menu display will
be entered ,flip 6 to “Pairing” to pair the remotes and sensors ; When pairing sensor ,you can choose Zone No. and Zone type before start pairing ;also you can change the Zone type after pairing ; P.S. If you could not make sure if a remotes or sensor has be paired or not ,you can inquiry the pairing ,then the LCD display will show the remotes or sensor be paired or not ,and meantime shows its real-‐time power volume ;
4. Flip 6 to “ Phone Number ”,and input the alarm numbers to receive phone call or SMS alert ;then flip 8 to finish the SMS setting(Alarms SMS; Arm/Disarm SMS; System SMS ) and Phone call setting ( Activate /Closed );
5. Flip 6 to “Voice message” to record the voice message ,so people whom receives phone call will know what happens when emergency;
6. For more settings, kindly pls follow its display menu to program .
Functions Explanation 1. Stress alarm
When you be threatened to disarm the system by intruder, you can input ( operation password plus 1 )+Disarm button ,the system will stealthily make alarm call and send SMS alert to other people .
2. Knock-‐over alarm When emergency ,you can knock over the panel to activate the alarming .
3. Temperature scope alarm You can program the temperature scope, so when temperature oversteps the scope, the panel will activate alarming .
4. Anti-‐false alarm Pair two sensors into one zone and activate the “False-‐alarm” in “Sensor pairing”,and activate “False-‐alarm” in “Switchs setting”. then only when two sensors be triggered successively over 6 seconds, alarming will be activated. This way can avoid false alarms which caused by sunshine exposure/wind blow/pet moving,etc…
5. Tamper alarm When panel be illegally disassembled, Panel will automatically activate the alarming ,and make alarm call and send SMS alert.
6. Door-‐open Alert ( two-‐way door contact supported ) Activate this function in “Switchs setting”. When door be forgot to close ,you will fail to arm the system ,meanwhile the LCD display will show “door open” to remind you to close the door .
7. Voice Memo (12 seconds) In disarm status, long press 9 via panel,it will start to record the voice memo ;long press 7 via panel to play the voice memo .
8. White list When this function be activated ,all the phone numbers you input are in white list by default .so you and other people don’t need to input Operation password ( 1234 ) to receive alarm calls.
9. Arm/Disarm Timers
Our system supports 6 timers for Arm/disarm .
10. Rename the SMS alert for 10 remotes / 16 zones You can rename those SMS alert by SMS commands: 123123#ZMSG=Zone No.,SMS alert 123123#RC1MSG=Remotes No.,SMS alert 123123#RC3MSG=Remotes No.,SMS alert For example: 1) rename the SMS alert of 16th zone to be “ an intruder breaks into
my front door”:123123#ZMSG=16,an intruder breaks into my front door
2) rename the SMS alert of Out arm button of 1st remotes to be “My son goes to school now”: 123123#RC1MSG=01,My son goes to school now
3) rename the SMS alert of Disarm button of 1st remotes to be “My son back home now”: 123123#RC3MSG=01,My son back home now
11.Work with wireless strobe siren (433Mhz) When strobe siren in pairing status, press 1234+Disarm via panel to get paired with strobe siren ,then will work together.
Many strobe sirens ( indoor or outdoor ) can be added with the panel to work at same time if need .
12. Work with two-‐way keypad When keypad in pairing status, press 1234+Disarm via panel to get paired with keypad ,then will work together.
System Settings By SMS Commands Besides programming on panel, this system can be finished settings remotely by SMS commands. Just text messages to panel as below, the correspondent setting will be finished exactly . Time for delay arm : 123123#02X# (X=00-‐90; 60 by default) Time for delay alarm: 123123#04X# (X=00-‐90; 00 by default) Time for delay disarm: 123123#05X# (X=00-‐90; 00 by default) Siren time: 123123#06X# (X=00-‐30; 01 by default) Backlight : 123123#09X# (X=000-‐180; 030 by default) Built-‐in siren volume: 123123#13X#
(X=0-‐3,0-‐mute,1-‐low,2-‐middle,3-‐high; 3 by default )
Phone number: 123123#41XY# (X= 1-‐6,Y=phone number) System time: 123123#50YYMMDDHHMM#
(YY=Year;MM=Month;DD=Day;HH=Hour;MM=Minute)
Timer for Arm/Disarm: 123123#56XYZHHMM# (X=1-‐6;Y=0-‐1,0-‐closed,1-‐activate;Z=1-‐3,1-‐Out arm,2-‐Home arm,3-‐Disarm; ) Program password: 123123#60X# (X=password, less than 6 digit; 123123 by default)
Operation password: 123123#61X# (X=password, less than 4 digit; 1234 by default) Zone type: 123123#64XYZM# (X=01-‐99;Y=1-‐6,1-‐closed,2-‐immediate,3-‐urgent,4-‐home,5-‐doorbell,6-‐delay;Z=0-‐1,0-‐voice prompt closed,1-‐voice prompt activated; M=0-‐1,0-‐false alarm closed,1-‐false alarm activated;) Temperature scope: 123123#78XYZ# (X=0-‐1,0-‐closed,1-‐activate;Y=lower limiting value; Z=upper
limit value)
System status setting: 123123#80X# (X=1-‐4,1-‐Out arm,2-‐Home arm,3-‐Disarm,4-‐SOS alarming )
Rename SMS alert for 16 zones : 123123#ZMSG=X,Y (X=01-‐99;Y=SMS alert)
Rename SMS alert for 10 remotes: 123123#RC1MSG=X,Y 123123#RC3MSG=X,Y (X=01-‐10,Y=SMS alert)
More Options Two-‐Way Keypad ( RFID Tags / LCD Display )
Mini Strobe Siren ( Red / Blue Lens )
Window Contact
Technical Specifications: Power input: DC 5V 2000mA,10Wh GSM frequency: 850/900/1800/1900Mhz Backup battery: 3.7V 1100mAh rechargeable Li-‐battery Built-‐in siren: 80dB Standby current: ≤60mA Alarm current: ≤300mA Radio frequency: 433.92MHz Extensible accessories: 10 remote controls,89 wireless detector/sensor History records : 60 Housing material: ABS plastic Operation condition: Temperature : -‐10℃~+55℃ Relative humidity: ≤80% (non-‐condensing ) Dimension (L x W x H): 140 x 140 x 20 mm