DESIGN OF FOOTING
Project : PROPOSED RENOVATION
Location : BUGO, CDOC
Owner : JOEFINA MOPON
DESIGN LOAD :
Axial Pu = 205.00 KN
MATERIAL DATA :
Concrete f'c = 20.70 MPa
w = 23.54 KN/m3
Soil qa = 150.00 KPa
w = 17.00 KN/m3
Steel Fy = 250.00 MPa
FOOTING DATA :
Width B = 1200 mm
Length L = 1200 mm
Thikness t = 300 mm
Depth D = 1000 mm
Min Cover d' = 100 mm
Effective Depth d = 200 mm
Col Dimension c = 200 mm
STRESSES :
Soil Bearing Pressure 110.48 KPa < 150.00 OK!Ultimate Net Soil Pressure
Qu = 142.36 KPa
Punching Shear 0.62 MPa < 1.52 OK!
Beam Shear 0.21 MPa < 0.76 OK!
STEEL REINFORCEMENT :
Steel Ratio pmin 0.0056
pmax 0.0317
Design Steel Ratio 0.0056
Steel Area 1,303.68 mm2
Main Bar Diameter 12 mmRequired 12 BW
-
7/28/2019 Slr Footing
2/7
DETAILED COMPUTATION
Footing Weight = 10.17 KN Puf = 132.26 KN
Soil Above Footing = 16.66 KN
Total Load P = 159.09 KN
Soil Bearing = 110.48 KPa
f1 = 142.36 Mpa
f2 = 142.36 Mpa
x = 500 mm
y = 300 mm
Punching ShearVp= 199.31 KN Qu ave = 142.36 Mpa
Ap = 320000 mm2
vp = 0.62 Mpa 1.52 Mpa
Shear Stress
Vs = 51.25 KN y= 300.00 mm
a= 900.00 mm
vs = 0.21 KN e= - Mpa
vall = 0.76 A= - Mpa
B= 142.36 Mpa
C= 142.36 Mpa
Ave = 142.36 Mpa
x= 500.00
STEEL REINFORCEMENT a= 700.00
e= -
Mu1 = 21.35 KN-m A= -
Mu2 = - KN-m B= 142.36
C= 142.36
Mu = 21.35 KN-m d= -
Mu = .90 f'c bd w( 1-0.59w )
894.24 w ( 1-0.59w )
w1 = 1.670689 p1 = 0.13833307
w2 = 0.024226 p2 = 0.00200591
Use p = 0.0056
-
7/28/2019 Slr Footing
3/7
Loads w t uw W TW
DL Flooring = 1.00 0.10 23.60 = 2.36 2.00 =
Floor Fin = 0.96 = 0.96 2.00 =
Partition = - = - 2.00 =
Ceiling = 0.25 = 0.25 2.00 =
Beams = 0.25 0.40 23.60 = 2.36 1.00 =
CHB Wall = 2.40 2.15 = 5.16 1.00 =
Column = 0.30 0.30 23.60 = 2.12 1.00 =
LL Occu = 2.40 = 2.40 2.00 =
Roof Flooring = 1.00 - 23.60 = - 2.00 =
Floor Fin = 1.50 = 1.50 2.00 =
Partition = - = - 2.00 =
Ceiling = 0.25 = 0.25 2.00 =
Beams = 0.20 0.35 23.60 = 1.65 1.00 =
CHB Wall = 2.60 2.15 = 5.59 1.00 =
Column = 0.30 0.30 23.60 = 2.12 1.00 =
Occu = 0.60 = 0.60 2.00 =
Pu =
Mu =
P =
-
7/28/2019 Slr Footing
4/7
Kpa
Kpa
Kpa
0.00560
-
7/28/2019 Slr Footing
5/7
TL
4.72 - = -
1.92 5.00 = 9.60
- 2.50 = -
0.50 5.00 = 2.50
2.36 6.50 = 15.34
5.16 4.00 = 20.64
2.12 4.00 = 8.50 56.58 79.21
4.80 5.00 = 24.00 24.00 40.80 120.01
- 2.50 = -
3.00 5.00 = 15.00
- 2.50 = -
0.50 5.00 = 2.50
1.65 6.50 = 10.74
5.59 2.70 = 15.09
2.12 3.00 = 6.37 49.70 69.58
1.20 5.00 = 6.00 6.00 10.20 79.78
199.79
24.97
136.28
-
7/28/2019 Slr Footing
6/7
DESIGN OF ISOLATED SQURE FOOTING
MARK
Date
Project
Location
Owner
DESIGN LOAD :
Axial Pu = 365.00 KN
Mu = 42.60 kN-m
MATERIAL DATA :
Concrete f'c = 20.70 MPa
w = 23.54 KN/m3
Soil qa = 200.00 KPa
w = 17.00 KN/m3Steel Fy = 275.00 MPa
FOOTING DATA :
Width B = 1200 mm
Length L = 1200 mm
Thikness t = 300 mm
Depth D = 1000 mm
Min Cover d' = 100 mm
Effective Depth d = 200 mm
Col Dimension c1 = 300 mm
c2 = 300 mm
STRESSES :
Soil Bearing Pressure 187.20 KPa < 200.00 OK!
Ultimate Net Soil Pressure
Qu = 278.98 KPa
Punching Shear 1.48 MPa < 1.52 OK!
Beam Shear 0.35 MPa < 0.76 OK!
STEEL REINFORCEMENT :
Steel Ratio pmin 0.0051
pmax 0.0280
Design Steel Ratio 0.0038
Steel Area 915.65 mm2
Main Bar Diameter 16 mm
Required 6 BW
FELOMINA/ ROQUE NERI
F1
3/1/2004
: PROPOSED 2 STORY RESIDENTIAL BUILDING
: Kauswagan, Cagayan de Oro City
-
7/28/2019 Slr Footing
7/7
Load Computation
FOR 2-STORY STRUCTURE
Loads w t uw W TW TL
DL Flooring = 1.00 0.10 23.60 = 2.36 4.50 = 10.62 2.50 = 26.55
Floor Fin = 0.25 = 0.25 4.50 = 1.13 2.50 = 2.81
Partition = - = - 4.50 = - 2.50 = -
Ceiling = 0.25 = 0.25 4.50 = 1.13 2.50 = 2.81
Beams = 0.25 0.35 23.60 = 2.07 1.00 = 2.07 7.00 = 14.46
CHB Wall = 2.65 2.15 = 5.70 1.00 = 5.70 4.50 = 25.64
Column = 0.25 0.25 23.60 = 1.48 4.50 = 6.64 4.00 = 26.55
LL Occu = 1.50 = 1.50 4.50 = 6.75 2.50 = 16.88
Roof Flooring = 1.00 - 23.60 = - 4.50 = - 2.50 = -
Floor Fin = 2.00 = 2.00 4.50 = 9.00 2.50 = 22.50
Partition = - = - 4.50 = - 2.50 = -
Ceiling = 0.25 = 0.25 4.50 = 1.13 2.50 = 2.81Beams = 0.20 0.20 23.60 = 0.94 1.00 = 0.94 5.50 = 5.19
CHB Wall = - 2.15 = - 1.00 = - 5.50 = -
Column = 0.25 0.25 23.60 = 1.48 1.00 = 1.48 3.00 = 4.43
Occu = 0.60 = 0.60 4.50 = 2.70 2.50 = 6.75
98.82 138.35
16.88 28.69 167.03
34.93 48.90
6.75 11.48 60.38
Pu = 227.41 kN
P = 157.37 kN