  • 7/28/2019 Slr Footing

    1/7

    DESIGN OF FOOTING

    Project : PROPOSED RENOVATION

    Location : BUGO, CDOC

    Owner : JOEFINA MOPON

    DESIGN LOAD :

    Axial Pu = 205.00 KN

    MATERIAL DATA :

    Concrete f'c = 20.70 MPa

    w = 23.54 KN/m3

    Soil qa = 150.00 KPa

    w = 17.00 KN/m3

    Steel Fy = 250.00 MPa

    FOOTING DATA :

    Width B = 1200 mm

    Length L = 1200 mm

    Thikness t = 300 mm

    Depth D = 1000 mm

    Min Cover d' = 100 mm

    Effective Depth d = 200 mm

    Col Dimension c = 200 mm

    STRESSES :

    Soil Bearing Pressure 110.48 KPa < 150.00 OK!Ultimate Net Soil Pressure

    Qu = 142.36 KPa

    Punching Shear 0.62 MPa < 1.52 OK!

    Beam Shear 0.21 MPa < 0.76 OK!

    STEEL REINFORCEMENT :

    Steel Ratio pmin 0.0056

    pmax 0.0317

    Design Steel Ratio 0.0056

    Steel Area 1,303.68 mm2

    Main Bar Diameter 12 mmRequired 12 BW

  • 7/28/2019 Slr Footing

    2/7

    DETAILED COMPUTATION

    Footing Weight = 10.17 KN Puf = 132.26 KN

    Soil Above Footing = 16.66 KN

    Total Load P = 159.09 KN

    Soil Bearing = 110.48 KPa

    f1 = 142.36 Mpa

    f2 = 142.36 Mpa

    x = 500 mm

    y = 300 mm

    Punching ShearVp= 199.31 KN Qu ave = 142.36 Mpa

    Ap = 320000 mm2

    vp = 0.62 Mpa 1.52 Mpa

    Shear Stress

    Vs = 51.25 KN y= 300.00 mm

    a= 900.00 mm

    vs = 0.21 KN e= - Mpa

    vall = 0.76 A= - Mpa

    B= 142.36 Mpa

    C= 142.36 Mpa

    Ave = 142.36 Mpa

    x= 500.00

    STEEL REINFORCEMENT a= 700.00

    e= -

    Mu1 = 21.35 KN-m A= -

    Mu2 = - KN-m B= 142.36

    C= 142.36

    Mu = 21.35 KN-m d= -

    Mu = .90 f'c bd w( 1-0.59w )

    894.24 w ( 1-0.59w )

    w1 = 1.670689 p1 = 0.13833307

    w2 = 0.024226 p2 = 0.00200591

    Use p = 0.0056

  • 7/28/2019 Slr Footing

    3/7

    Loads w t uw W TW

    DL Flooring = 1.00 0.10 23.60 = 2.36 2.00 =

    Floor Fin = 0.96 = 0.96 2.00 =

    Partition = - = - 2.00 =

    Ceiling = 0.25 = 0.25 2.00 =

    Beams = 0.25 0.40 23.60 = 2.36 1.00 =

    CHB Wall = 2.40 2.15 = 5.16 1.00 =

    Column = 0.30 0.30 23.60 = 2.12 1.00 =

    LL Occu = 2.40 = 2.40 2.00 =

    Roof Flooring = 1.00 - 23.60 = - 2.00 =

    Floor Fin = 1.50 = 1.50 2.00 =

    Partition = - = - 2.00 =

    Ceiling = 0.25 = 0.25 2.00 =

    Beams = 0.20 0.35 23.60 = 1.65 1.00 =

    CHB Wall = 2.60 2.15 = 5.59 1.00 =

    Column = 0.30 0.30 23.60 = 2.12 1.00 =

    Occu = 0.60 = 0.60 2.00 =

    Pu =

    Mu =

    P =

  • 7/28/2019 Slr Footing

    4/7

    Kpa

    Kpa

    Kpa

    0.00560

  • 7/28/2019 Slr Footing

    5/7

    TL

    4.72 - = -

    1.92 5.00 = 9.60

    - 2.50 = -

    0.50 5.00 = 2.50

    2.36 6.50 = 15.34

    5.16 4.00 = 20.64

    2.12 4.00 = 8.50 56.58 79.21

    4.80 5.00 = 24.00 24.00 40.80 120.01

    - 2.50 = -

    3.00 5.00 = 15.00

    - 2.50 = -

    0.50 5.00 = 2.50

    1.65 6.50 = 10.74

    5.59 2.70 = 15.09

    2.12 3.00 = 6.37 49.70 69.58

    1.20 5.00 = 6.00 6.00 10.20 79.78

    199.79

    24.97

    136.28

  • 7/28/2019 Slr Footing

    6/7

    DESIGN OF ISOLATED SQURE FOOTING

    MARK

    Date

    Project

    Location

    Owner

    DESIGN LOAD :

    Axial Pu = 365.00 KN

    Mu = 42.60 kN-m

    MATERIAL DATA :

    Concrete f'c = 20.70 MPa

    w = 23.54 KN/m3

    Soil qa = 200.00 KPa

    w = 17.00 KN/m3Steel Fy = 275.00 MPa

    FOOTING DATA :

    Width B = 1200 mm

    Length L = 1200 mm

    Thikness t = 300 mm

    Depth D = 1000 mm

    Min Cover d' = 100 mm

    Effective Depth d = 200 mm

    Col Dimension c1 = 300 mm

    c2 = 300 mm

    STRESSES :

    Soil Bearing Pressure 187.20 KPa < 200.00 OK!

    Ultimate Net Soil Pressure

    Qu = 278.98 KPa

    Punching Shear 1.48 MPa < 1.52 OK!

    Beam Shear 0.35 MPa < 0.76 OK!

    STEEL REINFORCEMENT :

    Steel Ratio pmin 0.0051

    pmax 0.0280

    Design Steel Ratio 0.0038

    Steel Area 915.65 mm2

    Main Bar Diameter 16 mm

    Required 6 BW

    FELOMINA/ ROQUE NERI

    F1

    3/1/2004

    : PROPOSED 2 STORY RESIDENTIAL BUILDING

    : Kauswagan, Cagayan de Oro City

  • 7/28/2019 Slr Footing

    7/7

    Load Computation

    FOR 2-STORY STRUCTURE

    Loads w t uw W TW TL

    DL Flooring = 1.00 0.10 23.60 = 2.36 4.50 = 10.62 2.50 = 26.55

    Floor Fin = 0.25 = 0.25 4.50 = 1.13 2.50 = 2.81

    Partition = - = - 4.50 = - 2.50 = -

    Ceiling = 0.25 = 0.25 4.50 = 1.13 2.50 = 2.81

    Beams = 0.25 0.35 23.60 = 2.07 1.00 = 2.07 7.00 = 14.46

    CHB Wall = 2.65 2.15 = 5.70 1.00 = 5.70 4.50 = 25.64

    Column = 0.25 0.25 23.60 = 1.48 4.50 = 6.64 4.00 = 26.55

    LL Occu = 1.50 = 1.50 4.50 = 6.75 2.50 = 16.88

    Roof Flooring = 1.00 - 23.60 = - 4.50 = - 2.50 = -

    Floor Fin = 2.00 = 2.00 4.50 = 9.00 2.50 = 22.50

    Partition = - = - 4.50 = - 2.50 = -

    Ceiling = 0.25 = 0.25 4.50 = 1.13 2.50 = 2.81Beams = 0.20 0.20 23.60 = 0.94 1.00 = 0.94 5.50 = 5.19

    CHB Wall = - 2.15 = - 1.00 = - 5.50 = -

    Column = 0.25 0.25 23.60 = 1.48 1.00 = 1.48 3.00 = 4.43

    Occu = 0.60 = 0.60 4.50 = 2.70 2.50 = 6.75

    98.82 138.35

    16.88 28.69 167.03

    34.93 48.90

    6.75 11.48 60.38

    Pu = 227.41 kN

    P = 157.37 kN