slide 1us silicon group meeting 5/6/2003 hybrid testing status 10 new hybrids brought by lenny all...
Post on 21-Dec-2015
213 views
TRANSCRIPT
Slide 1US silicon group meeting 5/6/2003
Hybrid Testing Status• 10 new hybrids brought by Lenny all tested
9 tested with no flaws 1 had 1 chip + 1 wirebond smashed
– Looks like smashed by a finger
– Probably occurred during taping down for shipping
• 10 new hybrids just arrived from FNAL Visually inspected
– One foot lift between hybrid-APV (long bond)
Test to keep up with production
Slide 2US silicon group meeting 5/6/2003
Ladder Testing Status• 8 modules bonded so far
1st module had 3 opens between PA-sensor (unbondable) and 2 opens added between sensor-sensor for testing
– Removed all bonds from problems found in sensor probing
– Two channels found to have high noise which increase with voltage (3.55.0 ADC)
Damage found on sensor 2nd-4th module had bias return bonds
missing– Damage to bulk unrepairable
Draw ~80 A, ~600 A, ~800 A
– 2 opens between APV-PA found in one module, otherwise no other bonding problems
– Will turn into x-calibration pieces with shorts and pinholes added on purpose
5th and 6th modules perfect– Three channels have high
noise which increases with voltage (1.51.9 ADC) and (1.79.0 ADC)
Damage found on sensor
7th module had wirebond damage on ~40 channels between APV and PA
– Not clear how or when 8th module had no bonding
problems– Channels found bad in sensor
probing pulled
– 2 channels has increasing noise vs. voltage (1.53.0 ADC)
Neighbors of pinhole found in probing
Slide 4US silicon group meeting 5/6/2003
Ladder Testing SummaryLadder Bias Current Sensor Bad
ChannelsBonding Bad Channels
Testing
Bad Channels
Total % Bad Channels
Grade Comments
876 1090 nA 1.5+2 3 1 1.4% B2 channels with high noise not in sensor probing
0018-P1 613 A 1.5Bulk
damage 5.5 1.4% FMissing bias bonds,
turn into x-calibration piece
0019-P1 758 A 1.5Bulk
damage 9.5 2.1% FMissing bias bonds,
turn into x-calibration piece
0024-P1 89 A 4.5Bulk
damage+2 1.5 1.2% F
Missing bias bonds, turn into x-
calibration piece; 2 opens during APV-
PA bonding
877 930 nA 0 (1??) 0 0 0.0% AOne channel has increasing noise
with voltage; sensor damage seen
878 1100 nA 0 (2??) 0 0 0.0% ATwo channels have
increasing noise with voltage;
sensor damage seen
879~ 40 smashed
wirebonds APV-PA, reconverable
880 720 nA 2(+2??) 0 0 0.3% ANeighbors of
pinhole noisy @ 550 V
Slide 5US silicon group meeting 5/6/2003
Summary• 4 of 8 bonded modules good
3 had bias return bonds missing 1 has ~40 APV-PA bonds smashed
– Can be repaired
• Of 4 good modules All have channels with increasing noise vs. voltage
– 2 channels on 1 ladder due to inherit pinhole
– 5 channels total on 3 ladders due to lithographic errors in sensor production
Not seen in wafer probing