Production and Safety starts from the ground; Production and Safety starts from the ground; up to the ridge of the roof. up to the ridge of the roof. Road base; emergency access Road base; emergency access Grade around all buildings; Grade around all buildings; allow for adequate access for rough terrain allow for adequate access for rough terrain lifts. lifts.

Upload: ffsafety

Post on 15-May-2015

1.374 views

Category:

Business


0 download

TRANSCRIPT

Page 1: Site Photos, 0608

Production and Safety starts from the ground; Production and Safety starts from the ground;

up to the ridge of the roof.up to the ridge of the roof.

Road base; emergency accessRoad base; emergency access Grade around all buildings;Grade around all buildings;

allow for adequate access for rough terrain lifts.allow for adequate access for rough terrain lifts.

Page 2: Site Photos, 0608

HousekeepingHousekeeping

Broom sweep before Broom sweep before sub-trades start their sub-trades start their work.work.

No No EATINGEATING in in buildings.buildings.

No No SMOKINGSMOKING in in buildings.buildings.

Page 3: Site Photos, 0608
Page 4: Site Photos, 0608

CAS SignageCAS Signage

CAZ SignageCAZ Signage Barricade to Barricade to

building access.building access.

Page 5: Site Photos, 0608

Proper Access to 2Proper Access to 2ndnd LevelLevel

Page 6: Site Photos, 0608

CAZ Requirement – CAZ Requirement – Warning LineWarning Line

Red warning line six feet Red warning line six feet from the exposed edge; from the exposed edge; continuous along the continuous along the building perimeter.building perimeter.

One monitor per six One monitor per six men.men.

Workers must have the Workers must have the sticker on their HH sticker on their HH designating the level designating the level where they are allowed where they are allowed to work.to work.

Page 7: Site Photos, 0608

Handrail – install Handrail – install immediatelyimmediately when wall is raised.when wall is raised.

Page 8: Site Photos, 0608

Proper Access to Proper Access to LandingsLandings

Supply Supply adequate adequate handrail.handrail.

Provide safe Provide safe access to next access to next level.level.

Maintain clear Maintain clear walkway; free of walkway; free of trip and fall trip and fall hazards.hazards.

Page 9: Site Photos, 0608

Access to RoofAccess to Roof

Provide an extension Provide an extension ladder or properly ladder or properly constructed site-built constructed site-built ladder for access to ladder for access to roof.roof.

The opening is a The opening is a minimum of 6’ from minimum of 6’ from the leading edge.the leading edge.

Page 10: Site Photos, 0608

Stocking MaterialsStocking Materials

Handrails must be Handrails must be maintained while maintained while stocking the building stocking the building with materials.with materials.

Good Housekeeping Good Housekeeping practices.practices.

Page 11: Site Photos, 0608

HOUSEKEEPING,HOUSEKEEPING, HOUSEKEEPING,HOUSEKEEPINGHOUSEKEEPING,HOUSEKEEPING

Page 12: Site Photos, 0608

HOUSEKEEPINGHOUSEKEEPING

Page 13: Site Photos, 0608

Roof Tie-Off Connection Roof Tie-Off Connection PointPoint

Use approved Use approved anchor; 5k lbsanchor; 5k lbs

Fill all holesFill all holes Fasten to trussFasten to truss

Page 14: Site Photos, 0608

ExcavationExcavationGeneral Inspection of Jobsite:General Inspection of Jobsite:

Excavations, adjacent areas, and protective systems inspected by Excavations, adjacent areas, and protective systems inspected by a competent person daily before the start of work. a competent person daily before the start of work.

Spoils, materials, and equipment set back at least two feet from Spoils, materials, and equipment set back at least two feet from the edge of the excavation. the edge of the excavation.

Barriers provided at all remotely located excavations, wells, pits, Barriers provided at all remotely located excavations, wells, pits, shafts, etc. shafts, etc.

Warning vests or other highly visible clothing provided and worn Warning vests or other highly visible clothing provided and worn by all employees exposed to public vehicular traffic.by all employees exposed to public vehicular traffic.

Utility companies contacted and/or utilities located. Utility companies contacted and/or utilities located. Exact location of utilities marked. Exact location of utilities marked. Underground installations protected, supported, or removed when Underground installations protected, supported, or removed when

excavation is open.excavation is open.

Page 15: Site Photos, 0608

Lateral travel to means of egress no greater than 25 feet in excavations Lateral travel to means of egress no greater than 25 feet in excavations four feet or more in depth.four feet or more in depth.

Ladders used in excavations secured and extended three feet above the Ladders used in excavations secured and extended three feet above the edge of the trench. edge of the trench.

Structural ramps used by employees designed by a competent person.Structural ramps used by employees designed by a competent person.

Wet Conditions:Wet Conditions:

Water removal equipment monitored by a competent person. Water removal equipment monitored by a competent person. Surface water or runoff diverted or controlled to prevent accumulation in Surface water or runoff diverted or controlled to prevent accumulation in

the excavation.the excavation. Inspections made after every rainstorm or other hazard-increasing Inspections made after every rainstorm or other hazard-increasing

occurrence.occurrence.

Means of EgressMeans of Egress

Page 16: Site Photos, 0608
Page 17: Site Photos, 0608

OSHA STANDERD 1926.502OSHA STANDERD 1926.502 Please review email file; “STD 03-00-001”Please review email file; “STD 03-00-001”

This is the Directive that governs residential stick frame construction.This is the Directive that governs residential stick frame construction.

Please review email file; “Interpretation Letters”.Please review email file; “Interpretation Letters”.This interpretation further defines the above standard.This interpretation further defines the above standard.

I highlighted the areas that pertain to Group I.I highlighted the areas that pertain to Group I.We will get into Groups III & IV latter. We will get into Groups III & IV latter. Group II does not pertain to wood-stick framed buildings.Group II does not pertain to wood-stick framed buildings.

The items in red are my comments.The items in red are my comments.