Simplifying the Routine LC/MS Analysis of Central Carbon Metabolites
Christine Miller
Omics Market Manager
June 8, 2016
Enabling Metabolomics Research
Agilent Technologies is the leading company with platforms and software that support metabolomics research
• Team of knowledgeable scientists dedicated to metabolomics
• Broad instrument portfolio (LC/MS, CE/MS, GC/MS, SFC/MS)
• Common MS raw data processing software
• Single statistics analysis software — use the same visualization andstatistical analysis tools for your metabolomics (and multi-omics!) study
• New MassHunter VistaFlux for qualitative flux analysis
• Seahorse technology for cellular metabolic analysis
2
Metabolomics dMRM Database and MethodIntegrated with Agilent’s Metabolomics Workflows
Database covers >215 central carbon metabolites
Designed for 1290 Flex pump and 6460/6470 QQQ LC/MS Systems
Provides an optimized method and database with stable, robust chromatography
Agilent Omics Workflows
3
QQQ DataAcquisition
&Analysis
QuantitationSeparate & Detect
StatisticsPathways
LC/QQQ Quant
Mass Profiler ProfessionalPathway Architect
For Research Use Only. Not for use in diagnostic procedures.
Metabolomics by Mass SpectrometryData Acquisition & Analysis
Targeted Data Acquisition – QQQ• Known metabolites only• Higher sensitivity than profiling approach• Absolute quantitation • Typically develop methods for tens/hundreds of metabolites• Project results onto biological pathways for interpretation
Discovery (Untargeted) Data Acquisition – TOF / Q-TOF• Acquire data and detect all compounds; relative quantitation.• Targeted data mining: − Analyze data with a database of known compounds− Project results onto pathways
• Untargeted data mining: − Find all compounds − Track metabolites using mass, or mass spectra and retention time
4
Benefits of QQQ Technology for Targeted Metabolomics
5
• Detect low level metabolites• Reduce sample required for analysisHigh Sensitivity
• Minimize matrix interference• Confirm compound identificationHigh Selectivity
• Analyze more compounds in a single run• Support fast chromatography
Fast MRM Transitions
• Provide reliable quantitation for differential analysis across a broad range of concentrations
Broad Dynamic Range
Metabolomics dMRM Database and MethodLC/QQQ SystemAgilent 1290 Infinity II LC system: • Infinity II Flex pump• Multisampler with chiller• Multicolumn Thermostat with 2-
position/6-port ultra high pressure valve
Agilent 6460 or 6470 Triple Quadrupole LC/MS system
Includes LC/MS method, database, quantitation method, and user guide
March 14, 2016
US HUPO 2016
LC/MS Method: Reverse Phase Ion Pair Chromatography• Better separation for acidic compounds
• Better protection for sugar phosphates and nucleotides
• Excellent retention time reproducibility across large sample sets
However: • Pump must be dedicated to the QQQ as ion pair reagents
stick to parts and cannot be effectively cleaned
• MS source can be easily cleaned allowing positive mode work
7
For Research Use Only. Not for use in diagnostic procedures.
Chromatographic Separation of Acidic MetabolitesNegative Mode Ionization
8
• Mobile phase: solvent A (97:3 water/methanol with 10 mM tributylamine + 15 mM acetic acid) and solvent B (97:3 acetonitrile/methanol with 10 mM tributylamine + 15 mM acetic acid).
• Columns: Zorbax RRHD Extend-C18 2.1 x 150 mm column and guard column
9
For Research Use Only. Not for use in diagnostic procedures.
Ion Pair Method Separates Biologically Relevant Isomers
IsoleucineLeucine
Glucose-6-phosphate
Glucose-1-phosphate
Demonstrated Robustness of Reverse Phase Ion Pair Chromatography
RT Reproducibility After 7 Months (> 4000 sample injections!)
10
For Research Use Only. Not for use in diagnostic procedures.
RT Deviation for 62 different samples over 3 days
RT for fresh column
RT
afte
r >40
00 s
ampl
es
Average RT across all samples
RT
acro
ss a
ll sa
mpl
es
Database: Curated MRM Transitions
The compound database with MRM transitions was developed together with the Rosebrock LabCompound and MRM transitions are extensively curated
11
Curation verifies these entries for correctness:Database MRM transitions
• Compound common name• MRM transitions (precursor and product m/z)• Fragmentor voltage• Collision energy• Retention time and retention time window• Unit mass of neutral molecule• Molecular formula• CAS number of the native compound
• MRM transitions have been optimized by collaborators
• Agilent curates dMRM data provided by Rosebrock lab and creates Master database and documentation.
The curated database eliminates the need to develop MRM transitions and retention times for a large numbers of compounds
For Research Use Only. Not for use in diagnostic procedures.
Easy Transfer From Database to Method in MassHunter Acquisition
12
For Research Use Only. Not for use in diagnostic procedures.
Simple Quantitative Batch Review and Export to MPP
13
MassHunter Quant Batch Review
Export to MPP
For Research Use Only. Not for use in diagnostic procedures.
Metabolomics is Uniquely Suited for Pre-built Methods: Compounds of Interest are Shared Across Organisms
The same metabolites and pathways are present across many organisms, allowing use of one method for many biological samples and questions.
14
Data from Adam Rosebrock Lab, University of Toronto
For Research Use Only. Not for use in diagnostic procedures.
Bacteria Yeast Tissues, cells, and biofluids
Customer Application: Antibiotic Mode of Action Discovery by Targeted Metabolomic Analysis
Objectives• Determine effects of drug perturbation on the metabolic network
• Generate metabolic fingerprints to characterize the mechanism of
action of novel biologically active molecules
Experimental approach• E. coli MG1655
• Synthetic minimal media (M9 glucose-ammonia)
• Dose-response design at a single time point
15
Example Application of Metabolomics dMRM Method: Identifying Metabolic Effects of Small Molecule Treatment
Inhibition of metabolism causes predictable changes in metabolite levels
Metabolites upstream of the blockade accumulate, while downstream metabolites are depleted
Typically, multiple compounds upstream and downstream are affected, allowing identification of the inhibited pathway even in cases where not all metabolites can be measured
16
Data from Adam Rosebrock Lab, University of Toronto
For Research Use Only. Not for use in diagnostic procedures.
XCompound 1 Compound 2 Compound 3 Compound 4 Compound 5
Targeted Metabolomics Analysis Reveals Dose-dependent Biochemical Responses to Drug Treatment
• E. coli cultures were treated in replicate across a dose-response series as shown
• Cultures were processed as detailed in the method quick-start guide.
• Data were extracted in MassHunter Quant and processed in Mass Profiler Professional
• Heat-map displaying relative changes in each of ~215 metabolites is shown here. Dynamic range is 64-fold
17
Data from Adam Rosebrock Lab, University of Toronto
For Research Use Only. Not for use in diagnostic procedures.
[Glyphosate µM]0 62 12531 250 500
Mass Profiler Professional and Pathway Architect Identify the Target of Glyphosate
18
Data from Adam Rosebrock Lab, University of Toronto
For Research Use Only. Not for use in diagnostic procedures.
EPSP Synthase, the target of glyphosate
19
Data from Adam Rosebrock Lab, University of Toronto
For Research Use Only. Not for use in diagnostic procedures.
• Technical replicates (6x) of pooled biological samples treated with three concentrations levels of drug were analyzed
• Replicates were analyzed interspersed across days of runs
• Data demonstrate consistent signal response and reproducible retention
Analytical Reproducibility Enables “Hands Off” Quantitation
Metabolic Changes Include Local Effects and Characteristic Global Responses - a Fingerprint of Mode of Action
20
Data from Adam Rosebrock Lab, University of Toronto
For Research Use Only. Not for use in diagnostic procedures.
Summary
Metabolomics dMRM Database and Method provides an optimized, robust method for routine targeted analysis of more than 215 central carbon metabolites
Agilent offers an comprehensive metabolomics portfolio that includes sample preparation, data acquisition and data analysis
June 8, 2016
Confidentiality Label
21