simcom sim5320 atc en v1.23

498
AT Command Set SIM5320 _ATC_V1.23

Upload: anonymous-sngdnmf7qj

Post on 14-Apr-2016

147 views

Category:

Documents


5 download

DESCRIPTION

COMANDOS AT MODULO SIM5320

TRANSCRIPT

Page 1: Simcom Sim5320 Atc en v1.23

AT Command Set SIM5320 _ATC_V1.23

Page 2: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 1

Document Title: SIM5320 AT Command Set

Version: 1.23

Date: 2012-05-14

Status: Release

Document ID: SIM5320_ATC_V1.23

General Notes SIMCom offers this information as a service to its customers, to support application and engineering efforts that use the products designed by SIMCom. The information provided is based upon requirements specifically provided to SIMCom by the customers. SIMCom has not undertaken any independent search for additional relevant information, including any information that may be in the customer’s possession. Furthermore, system validation of this product designed by SIMCom within a larger electronic system remains the responsibility of the customer or the customer’s system integrator. All specifications supplied herein are subject to change.

Copyright This document contains proprietary technical information which is the property of SIMCom Limited., copying of this document and giving it to others and the using or communication of the contents thereof, are forbidden without express authority. Offenders are liable to the payment of damages. All rights reserved in the event of grant of a patent or the registration of a utility model or design. All specification supplied herein are subject to change without notice at any time.

Copyright © Shanghai SIMCom Wireless Solutions Ltd. 2012

Page 3: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 2

Vers ion History

Version Chapter Comments

V1.00 New Version

V1.01 5.23 AT+CMGSEX 6.30 AT+CPLMNWLIST 6.31 AT+CPASSMGR 7.20 AT+CDELTA 9.20 AT+CECM 9.21 AT+CNSM 9.22 AT+CECSET 9.37 AT+CADCI 9.38 AT+CUSBSPD 9.39 AT+CLEDITST 12.11 AT+FSCOPY 16.3 AT+CSOCKAUTH 16.19 AT+CIPCLOSE 18.7.1 AT+CHTPSERV 18.7.2 AT+CHTPUPDATE 19.14 AT+CMMSRECV 21.9 AT+CGPSNMEA

Modify the description of this command Modify the description of this command Modify the description of this command Modify the description of this command Modify the description of this command Add this command Add this command Add this command Add this command Add this command Add this command Modify the description of this command Modify the description of this command Add this command Add this command Modify the description of this command Add this command

V1.02 4.33 AT+CSSN Remove this command

V1.03 9.36 AT+CADCI 15.3 AT+CGEQREQ 19.14 AT+CMMSRECV

Modify the description of value of this command Modify the examples of this command Modify the description of this command

V1.04 4.21 AT+CMIC 6.4 AT+CPWD 6.26 AT+CCINFO 9.19 AT+SIDET 9.20 AT+CECM 9.21 AT+CNSM 9.22 AT+CECSET 9.28 AT+CDTRISRMD 9.29 AT+CDTRISRS 9.30 AT+CGFUNC 9.32 AT+CGWISRMD 9.35 AT+CADCI 9.36 AT+CUSBSPD 9.37 AT+CLEDITST 12.2 AT+FSMKDIR 12.8 AT+FSMEM

Remove this command Modify the value description of this command Modify the value description of this command Modify the default value of this command Modify the description of this command Modify the description of this command Modify the description of this command Modify the description of this command Modify the description of this command Modify the description of this command Modify the description of this command Modify the description of this command Modify the description of this command Modify the description of this command Modify the description of this command Modify the description of this command

Page 4: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 3

12.9 AT+FSFMT 16.5 AT+NETOPEN 19.7 AT+CMMSSEND 19.13 AT+CMMSDELBCC 21.1 AT+CGPS 21.2 AT+CGPSINFO 21.5 AT+CGPSSWITCH 21.7 AT+CGPSSSL 21.8 AT+CGPSAUTO 21.10 AT+CGPSMD 21.11 AT+CGPSFTM

Remove this command Modify the description of this command Modify the description of this command Modify the description of this command Add read command of this command Modify the description of this command Modify default baud rate value Modify the description of this command Modify the description of this command Add this command Add this command

V1.05 4.26 AT+CSDVC 6.26 AT+CCINFO 7.21 AT+CDIPR 7.22 AT+CUDIAG 9.29 AT+CDTRISRS 12.1 AT+FSCD 12.2 AT+FSMKDIR 13.1 AT+CTXFILE 13.2 AT+CRXFILE 15.2 AT+CGQREQ 15.4 AT+CGQMIN 15.5 AT+CGEQMIN 16.1 AT+CGSOCKCONT 16.3 AT+CSOCKAUTH 18.3.7 AT+CFTPGETFILE 18.3.8 AT+CFTPPUTFILE 18.5.5 AT+ CHTTPSSEND 18.6.12 AT+CFTPSGETFILE 18.6.13 AT+CFTPSPUTFILE 19.2 AT+CMMSPROTO 19.5 AT+CMMSDOWN 19.7 AT+CMMSSEND 19.14 AT+CMMSRECV 21.2 AT+CGPSINFO

Modify the description of this command Modify the description of this command Add this command Add this command Modify the description of this command Modify the examples of this command Modify the examples of this command Modify the examples of this command Modify the description of this command Modify the examples of this command Modify the examples of this command Modify the examples of this command Modify the description of this command Modify the test command of this command Modify the description of this command Modify the description of this command Modify the write command of this command Modify the description of this command Modify the description of this command Modify the description of this command Modify the description of this command Modify the description of this command Modify the description of this command Add course information

V1.06 6.16 AT+CPOL 6.34 AT+CNSVN 12 FileSystem Related Commands 14.10 ATV 18.1.6 AT+SMTPBODY 18.5.6 AT+CHTTPSRECV 18.6.11 AT+CFTPSLIST

Modify the description of this command Remove read command of this command Modify the description of this section Add this command Modify the description of this command Modify the description of this command Modify the execute command of this command

Page 5: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 4

18.6.15 AT+CFTPSPUT 18.7.1 AT+CHTPSERV 19 MMS Commands 19.5 AT+CMMSDOWN 21.1 AT+CGPS 22 Result codes 23.2.2 TCP client

Modify the description of this command Modify the description of this command Add the description of this section Modify the description of this command Modify the description of this command Add this section Modify the description of this command

V1.07 5.1 CMS ERROR 6.7 AT+COLP 6.10 AT+CCWA 6.15 AT+CLCC 7.7 AT+AUTOCSQ 12.3 AT+FSRMDIR 12.9 AT+FSLOCA 13.1 AT+CTXFILE 16.3 AT+CSOCKAUTH 18.2.10 AT+POP3READ 18.5.5 AT+CHTTPSSEND 18.5.6 AT+CHTTPSRECV 21.6 AT+CGPSURL

Add two value of <err> of this command Modify the description of this command Modify the description of this command Modify this command Modify this command Modify the description of this command Modify the description of this command Add note for <filename> of this command Modify the examples of this command Modify <location> value range of this command Add the <result> value description of this command Add the <result> value description of this command Modify the description of this command

V1.08 9.29 AT+CDTRISRS Modify this command

V1.09 3.1 ATI 3.4 AT+CGMR 6.5 AT+CLIP 6.16 AT+CPOL 9.35 AT+CADCI 9.37 AT+CADCA 16.9 AT+SERVERSTART 16.17 AT+CIPOPEN 16.18 AT+CIPSEND 17.1 AT+STIN 18.1.4 AT+SMTPRCPT 18.7.1 AT+CHTPSERV 18.7.2 AT+CHTPUPDATE 20.6 AT+PRINTDIR 23.2.2 TCP client

Modify this command Modify examples of this command Modify this command Modify this command Remove this command Add this command Modify this command Modify this command Modify this command Modify this command Modify read command response this command Modify this command Modify read command response this command Add this command Modify this section

V1.10 4.3 ATD 5.16 AT+CSMP 5.22 AT+CMGWO 6.22 AT+CPSI 13.2 AT+CMWAIT 16.3 AT+CSOCKAUTH

Add note for defined value <;> of this command Modify the write command of this command Modify parameter <toda> range of this command Add value Offline for <Operation Mode> parameter Add this command Modify this command

Page 6: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 5

16.7 AT+TCPWRITE 16.8 AT+UDPSEND 16.22 AT+CIPSTAT 16.23 information about TCP 18.1.3 AT+SMTPFROM 18.1.7 AT+SMTPFILE 18.2.4 AT+POP3LIST 18.2.6 AT+POP3GET 18.6.11 AT+CFTPSLIST 18.6.16 AT+CFTPSSINGLEIP 22.2Response string of AT+CEER

Modify this command Modify this command Modify this command Modify the description Modify this command Modify the description of this command Modify this command Modify the description of this command Modify the description of this command Modify the description of this command Add this section

V1.11 13.3 AT+CMWAIT Add Execution Command of this command

V1.12 4.22 AT+AUTOANSWER 4.24 AT+CPTONE 5.8 AT+CNMA 11.6 AT+CEMNLIST 12.5 AT+FSDEL 13.1 AT+CTXFILE 15.3 AT+CGEQREQ 15.5 AT+CGEQMIN 18.6.3 AT+CFTPSLOGIN 19.8 AT+CMMSRECP 19.9 AT+CMMSCC 19.10 AT+CMMSBCC 19.12 AT+CMMSDELCC 19.18 AT+CMMSSAVE 9.8 AT+CRIIC

Modify this command Modify this command Modify this command Modify the description of this command Modify this command Modify the description of this command Modify this command Modify this command Modify this command Modify write Command of this command Modify write Command of this command Modify write Command of this command Modify execute command of this command Modify write Command of this command Modify this command

V1.13 9.38 AT+CAPWRON 9.39 AT+CAPWROFF 13.3 AT+CMWAIT

Add this command Add this command Modify this command

V1.14 4.3 ATD 4.22 AT+AUTOANSWER 4.26 AT+CSDVC 5.15 AT+CMGD 9.25 AT+CMUX 9.26 AT+CMUXSRVPORT

Modify the description of this command Modify the description of this command Modify this command Modify the description of this command Add this command Add this command

V1.15 4.3 ATD 4.32 AT+CODEC 6.37 AT+CCGMDF 6.38 AT+CPLMNPASS 21.2 AT+CGPSINFO 21.12 AT+CGPS

Modify the description of this command Add this command Add this command Add this command Modify this command Add this command

Page 7: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 6

22.1 AT+CSVM 22.2 Indication of Voice Mail 23.1 Indication of EONS 24.1 AT+COTADPHONENUMBER

Add this command Add this command Add this command Add this command

V1.16 9.26 AT+CMUXSRVPORT 9.42 AT+CBVTBP

Modify this command Add this command

V1.17 3.9 AT+CATR 4.32 AT+CODEC 5.10 AT+CMGL 5.11 AT+CMGR 5.13 AT+CMSS 5.14 AT+CMGW 5.21 AT+CMGSO 5.23 AT+CMGSEX 6.30 AT+CPLMNWLIST 8.3 AT+CRSM 16.17 AT+CIPOPEN 16.18 AT+CIPSEND 16.21 AT+CDNSGHNAME 21.2 AT+CGPSINFO 21.13 AT+CGPSXE 21.14 AT+CGPSXD

Modify <port> value of this command Modify default value of this command Modify <toda> value of this command Modify <toda> value of this command Modify <toda> value of this command Modify <toda> value of this command Modify <toda> value of this command Modify <toda> value of this command Modify <plmnwlist> value of this command Modify this command Modify this command Modify this command Add this command Modify this command Add this command Add this command

V1.18 4.19 AT+CLVL 5.23 AT+CMGSEX 6.10 AT+CCWA 6.16 AT+CPOL 6.22 AT+CPSI 6.26 AT+CCINFO 7.23 AT+CUDLOADS 9.16 AT+CGISR 9.18 AT+CVLVL 9.22 AT+CECSET 9.25 AT+CMUX 15.2 AT+CGDSCONT 15.3 AT+CGTFT 16.4 AT+CGSOCKQREQ 16.5 AT+CGSOCKEQREQ 16.6 AT+CGSOCKQMIN 16.7 AT+CGSOCKEQMIN 16.16 AT+CIPCCFG 16.17 AT+CIPOPEN 16.18 AT+CIPSEND

Modify this command Modify this command Modify this command Modify this command Modify this command Modify this command Add this command Add this command Modify this command Modify this command Modify this command Add this command Add this command Add this command Add this command Add this command Add this command Modify this command Modify this command Modify this command

Page 8: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 7

16.28 AT+CTCPFIN 16.29 AT+CENDUPPDP 16.30 AT+CTCPKA 16.31 AT+CPING 16.32 AT+CPINGSTOP 18.1.8 AT+SMTPSEND 18.2.6 AT+POP3GET 18.3.10 AT+CFTPPUT 18.4.1 AT+CHTTPACT 19.5 AT+CMMSDOWN 19.7 AT+CMMSSEND 19.16 AT+CMMSREAD 21.1 AT+CGPS 21.12 AT+CGPSDEL 21.13 AT+CGPSNOTIFY 24.1 AT+COTADPHONENUMBER

Add this command Add this command Add this command Add this command Add this command Modify this command Modify this command Modify this command Modify this command Modify this command Modify this command Modify this command Modify this command Add this command Modify this command Modify this command

V1.19 5.14 AT+CMGW 6.39 AT*CNTI 9.19 AT+CVLVL 9.44 AT+CRFOP 15.1 AT+CGDCONT 16.1 AT+CGSOCKCONT 16.20 AT+CIPCCFG 16.30 AT+CTCPKA 16.33 AT+CTEUTP 16.34 AT+CUPURE 16.35 AT+CINICMPALLOW 17.4 AT+STK 18.2.1 AT+POP3SRV 18.2.2 AT+POP3IN 18.2.6 AT+POP3GET 18.3.6 AT+CFTPPW 18.3.7 AT+CFTPGETFILE 18.3.8 AT+CFTPPUTFILE 18.3.9 AT+CFTPGET 18.3.10 AT+CFTPPUT 18.4.1 AT+CHTTPACT 21.2 AT+CGPSINFO 21.14 AT+ CGPSXE 21.15 AT+CGPSXD 21.16 AT+CGPSXDAUTO 21.16.1 AT+CASSISTLOC

Bug10482:Under the PUD mode,there’s an unwanted commaAdd this command Modify the note section Add this command Modify the example section Modify the example section Modify write command section Add a parameter

Add this command Add this command Add this command Add this command bug10752 Bug 10522 bug10759 bug10872 Add field <rest_size> Add field <rest_size> Add field <rest_size>/ bug10871 Add field <rest_size> MKBUG00000205 Bug10481:Add the explain section of read command Modify this command Modify this command Add this command Add this command

Page 9: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 8

21.16.2 AT+ CASSISTLOCTRYTIMES 21.16.3 AT+ CASSISTLOCMODE

Add this command Add this command

V1.20 4.33 AT+CVOC 6.16 AT+CPOL 6.22 AT+CPSI 7.11 AT+CPOF 7.23 AT+CUDLOADS 16.30 AT+CTCPKA 19.7 AT+CMMSSEND 21.17 AT+CGPSINFOCFG

MKBUG00000214 MKBUG00000110/MKBUG00000219 MKBUG00000238 bug10918 MKBUG00000242 MKBUG00000221 MKBUG00000239 Add this command

V1.21 11.4 AT+CPBF 16.9 AT+NETOPEN 16.13 AT+SERVERSTART 16.36 AT+TCPCLOSE 19.22 AT+CMMSUA 19.23 AT+CMMSPROFILE

MKBUG00000310 MKBUG00000529 MKBUG00000529 MKBUG00000529 MKBUG00000564 MKBUG00000564

V1.22 6.1 AT+CREG 9.33 AT+CGFUNC 15.14 AT+CGREG 19.7 AT+CMMSSEND 19.8 AT+CMMSRECP 19.9 AT+CMMSCC 19.10 AT+CMMSBCC 19.11 AT+CMMSDELRECP 19.12 AT+CMMSDELCC 19.13 AT+CMMSDELBCC

MKBUG00000317 MKBUG00000302 MKBUG00000317 MKBUG00000601 MKBUG00000601 MKBUG00000601 MKBUG00000601 MKBUG00000601 MKBUG00000601 MKBUG00000601

V1.23 9.13 AT+CGDRT 9.14 AT+CGSETV 16.11 AT+TCPWRITE 16.12 AT+UDPSEND 16.13 AT+SERVERSTART 16.27 AT+CIPSTAT 16.37 Information elements related to TCP/IP 18.1.5 AT+SMTPSUB 18.1.7 AT+SMTPFILE 18.1.7 AT+SMTPBCH 18.2.2 AT+POP3IN 18.2.3 AT+POP3NUM 18.2.6 AT+POP3GET 18.2.8 AT+POP3OUT 18.3.4 AT+CFTPSERV 18.3.5 AT+CFTPUN

MKBUG00000715 MKBUG00000715 MKBUG00000312 MKBUG00000312 MKBUG00000900 MKBUG00000358 Add +NETCLOSE: 1/ MKBUG00000900 MKBUG00000843 MKBUG00000843 Add this command MKBUG00000416 MKBUG00000419 MKBUG00000420 MKBUG00000416 MKBUG00000434 MKBUG00000312

Page 10: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 9

18.3.6 AT+CFTPPW 18.3.9 AT+CFTPGET 18.3.10 AT+CFTPPUT 18.3.11 AT+CFTPLIST 19.4 AT+CMMSEDIT 19.19 AT+CMMSDELETE 19.22 AT+CMMSUA 19.23 AT+CMMSPROFILE 22.1 AT+CSVM

MKBUG00000436 MKBUG00000438 MKBUG00000544/MKBUG00000448 MKBUG00000437 MKBUG00000362/MKBUG00000363 MKBUG00000396 MKBUG00000813 MKBUG00000816 MKBUG00000633

Page 11: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 10

Contents V e r s i o n H i s t o r y ........................................................................................................................... 2 C o n t e n t s .......................................................................................................................................... 10 1 Introduction.................................................................................................................................... 21

1.1 Scope.................................................................................................................................................... 21 1.2 References ............................................................................................................................................ 21 1.3 Terms and abbreviations....................................................................................................................... 21 1.4 Definitions and conventions................................................................................................................. 22

2 AT Interface Synopsis.................................................................................................................... 24 2.1 Interface settings .................................................................................................................................. 24 2.2 AT command syntax............................................................................................................................. 24 2.3 Information responses .......................................................................................................................... 25

3 General Commands ....................................................................................................................... 26 3.1 ATI Display product identification information ................................................................................ 26 3.2 AT+CGMI Request manufacturer identification ............................................................................... 27 3.3 AT+CGMM Request model identification ........................................................................................ 27 3.4 AT+CGMR Request revision identification ...................................................................................... 28 3.5 AT+CGSN Request product serial number identification ................................................................. 29 3.6 AT+CSCS Select TE character set .................................................................................................... 29 3.7 AT+CIMI Request international mobile subscriber identity ............................................................. 31 3.8 AT+GCAP Request overall capabilities ............................................................................................ 31 3.9 AT+CATR Configure URC destination interface.............................................................................. 32 3.10 A/ Repeat last command.................................................................................................................... 33 3.11 AT+CFGRI Indicate RI when using URC......................................................................................... 33

4 Call Control Commands and Methods........................................................................................... 35 4.1 AT+CSTA Select type of address ...................................................................................................... 35 4.2 AT+CMOD Call mode ...................................................................................................................... 36 4.3 ATD Dial command .......................................................................................................................... 37 4.4 ATD><mem><n> Originate call from specified memory................................................................. 38 4.5 ATD><n> Originate call from active memory (1)............................................................................. 39 4.6 ATD><str> Originate call from active memory (2)........................................................................... 40 4.7 ATA Call answer................................................................................................................................ 40 4.8 +++ Switch from data mode to command mode ............................................................................... 41 4.9 ATO Switch from command mode to data mode .............................................................................. 41 4.10 AT+CVHU Voice hang up control .................................................................................................... 42 4.11 ATH Disconnect existing call............................................................................................................ 43 4.12 AT+CHUP Hang up call.................................................................................................................... 44 4.13 AT+CBST Select bearer service type ................................................................................................ 45 4.14 AT+CRLP Radio link protocol .......................................................................................................... 46 4.15 AT+CR Service reporting control...................................................................................................... 48 4.16 AT+CEER Extended error report ...................................................................................................... 49 4.17 AT+CRC Cellular result codes .......................................................................................................... 49

Page 12: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 11

4.18 AT+VTS DTMF and tone generation................................................................................................ 51 4.19 AT+CLVL Loudspeaker volume level............................................................................................... 52 4.20 AT+VMUTE Speaker mute control .................................................................................................. 53 4.21 AT+CMUT Microphone mute control............................................................................................... 54 4.22 AT+AUTOANSWER Automatic answer quickly ............................................................................. 54 4.23 ATS0 Automatic answer.................................................................................................................... 56 4.24 AT+CALM Alert sound mode........................................................................................................... 56 4.25 AT+CRSL Ringer sound level........................................................................................................... 57 4.26 AT+CSDVC Switch voice channel device ........................................................................................ 58 4.27 AT+CPTONE Play tone .................................................................................................................... 59 4.28 AT+CPCM External PCM codec mode configuration ...................................................................... 61 4.29 AT+CPCMFMT Change the PCM format......................................................................................... 62 4.30 AT+CPCMREG Control PCM data transfer by diagnostics port ...................................................... 63 4.31 AT+VTD Tone duration .................................................................................................................... 64 4.32 AT+CODEC Set audio codec mode .................................................................................................. 65 4.33 AT+CVOC Get the current vocoder capability in a call.................................................................... 66

5 SMS Related Commands............................................................................................................... 68 5.1 +CMS ERROR Message service failure result code ......................................................................... 68 5.2 AT+CSMS Select message service.................................................................................................... 69 5.3 AT+CPMS Preferred message storage .............................................................................................. 70 5.4 AT+CMGF Select SMS message format........................................................................................... 72 5.5 AT+CSCA SMS service centre address............................................................................................. 73 5.6 AT+CSCB Select cell broadcast message indication......................................................................... 73 5.7 AT+CSDH Show text mode parameters............................................................................................ 75 5.8 AT+CNMA New message acknowledgement to ME/TA.................................................................. 76 5.9 AT+CNMI New message indications to TE ...................................................................................... 77 5.10 AT+CMGL List SMS messages from preferred store ....................................................................... 79 5.11 AT+CMGR Read message ................................................................................................................ 83 5.12 AT+CMGS Send message................................................................................................................. 87 5.13 AT+CMSS Send message from storage ............................................................................................ 88 5.14 AT+CMGW Write message to memory ............................................................................................ 89 5.15 AT+CMGD Delete message.............................................................................................................. 91 5.16 AT+CSMP Set text mode parameters ................................................................................................ 92 5.17 AT+CMGRO Read message only ..................................................................................................... 93 5.18 AT+CMGMT Change message status ............................................................................................... 94 5.19 AT+CMVP Set message valid period................................................................................................ 95 5.20 AT+CMGRD Read and delete message ............................................................................................ 96 5.21 AT+CMGSO Send message quickly ................................................................................................. 97 5.22 AT+CMGWO Write message to memory quickly ............................................................................ 98 5.23 AT+CMGSEX Send message............................................................................................................ 99 5.24 AT+CMGENREF Generate a new message reference .................................................................... 101

6 Network Service Related Commands .......................................................................................... 102 6.1 AT+CREG Network registration ..................................................................................................... 102

Page 13: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 12

6.2 AT+COPS Operator selection ......................................................................................................... 103 6.3 AT+CLCK Facility lock .................................................................................................................. 105 6.4 AT+CPWD Change password ......................................................................................................... 107 6.5 AT+CLIP Calling line identification presentation ........................................................................... 108 6.6 AT+CLIR Calling line identification restriction.............................................................................. 109 6.7 AT+COLP Connected line identification presentation .....................................................................111 6.8 AT+CCUG Closed user group..........................................................................................................112 6.9 AT+CCFC Call forwarding number and conditions.........................................................................113 6.10 AT+CCWA Call waiting...................................................................................................................115 6.11 AT+CHLD Call related supplementary services ..............................................................................117 6.12 AT+CUSD Unstructured supplementary service data ......................................................................118 6.13 AT+CAOC Advice of charge ...........................................................................................................119 6.14 AT+CSSN Supplementary service notifications.............................................................................. 120 6.15 AT+CLCC List current calls............................................................................................................ 122 6.16 AT+CPOL Preferred operator list.................................................................................................... 124 6.17 AT+COPN Read operator names .................................................................................................... 126 6.18 AT+CNMP Preferred mode selection.............................................................................................. 127 6.19 AT+CNBP Preferred band selection................................................................................................ 127 6.20 AT+CNAOP Acquisitions order preference .................................................................................... 129 6.21 AT+CNSDP Preferred service domain selection............................................................................. 129 6.22 AT+CPSI Inquiring UE system information ................................................................................... 130 6.23 AT+CNSMOD Show network system mode................................................................................... 132 6.24 AT+CTZU Automatic time and time zone update........................................................................... 133 6.25 AT+CTZR Time and time zone reporting ....................................................................................... 134 6.26 AT+CCINFO Show cell system information................................................................................... 136 6.27 AT+CSCHN Show cell channel information................................................................................... 138 6.28 AT+CSRP Show serving cell radio parameter................................................................................. 139 6.29 AT+CRUS Show cell set system information ................................................................................. 140 6.30 AT+CPLMNWLIST Manages PLMNs allowed by customer............................................................ 142 6.31 AT+CPASSMGR Manage password .................................................................................................. 142 6.32 AT+CNSVSQ Network band scan quickly ..................................................................................... 143 6.33 AT+CNSVS Network full band scan in string format ..................................................................... 145 6.34 AT+CNSVN Network full band scan in numeric format ................................................................ 148 6.35 AT+CNSVUS Network band scan by channels in string ................................................................ 150 6.36 AT+CNSVUN Network band scan by channels in numeric............................................................ 152 6.37 AT+CCGMDF Enable single mode in RAT balancing mode.......................................................... 154 6.38 AT+CPLMNPASS Manage PLMN filter password ........................................................................... 155 6.39 AT*CNTI Query Network Mode .................................................................................................... 155

7 Mobile Equipment Control and Status Commands ..................................................................... 157 7.1 +CME ERROR Mobile Equipment error result code...................................................................... 157 7.2 AT+CMEE Report mobile equipment error .................................................................................... 160 7.3 AT+CPAS Phone activity status ...................................................................................................... 161 7.4 AT+CFUN Set phone functionality ................................................................................................. 162

Page 14: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 13

7.5 AT+CPIN Enter PIN........................................................................................................................ 163 7.6 AT+CSQ Signal quality................................................................................................................... 164 7.7 AT+AUTOCSQ Set CSQ report...................................................................................................... 165 7.8 AT+CACM Accumulated call meter ............................................................................................... 166 7.9 AT+CAMM Accumulated call meter maximum............................................................................. 167 7.10 AT+CPUC Price per unit and currency table................................................................................... 168 7.11 AT+CPOF Control phone to power down ....................................................................................... 169 7.12 AT+CCLK Real time clock ............................................................................................................. 170 7.13 AT+CRFEN RF check at initialization............................................................................................ 171 7.14 AT+CRESET Reset ME .................................................................................................................. 172 7.15 AT+SIMEI Set module IMEI .......................................................................................................... 172 7.16 AT+CSIMLOCK Request and change password ............................................................................ 173 7.17 AT+DSWITCH Change diagnostics port mode .............................................................................. 175 7.18 AT+CNVW Write NV item............................................................................................................. 176 7.19 AT+CNVR Read NV item............................................................................................................... 178 7.20 AT+CDELTA Write delta package to FOTA partition..................................................................... 180 7.21 AT+CDIPR Set UART baud rate..................................................................................................... 181 7.22 AT+CUDIAG Switch UART from AT service to DIAG service..................................................... 182 7.23 AT+CUDLOADS Switch to UART download mode...................................................................... 182

8 SIMCard Related Commands ...................................................................................................... 184 8.1 AT+CICCID Read ICCID in SIM card ........................................................................................... 184 8.2 AT+CSIM Generic SIM access ....................................................................................................... 184 8.3 AT+CRSM Restricted SIM access .................................................................................................. 185 8.4 AT+CSIMSEL Switch between two SIM card................................................................................ 190 8.5 AT+SPIC Times remain to input SIM PIN/PUK............................................................................. 191 8.6 AT+CSPN Get service provider name from SIM............................................................................ 192

9 Hardware Related Commands ..................................................................................................... 192 9.1 AT+CTXGAIN Set TX gain............................................................................................................ 192 9.2 AT+CRXGAIN Set RX gain ........................................................................................................... 193 9.3 AT+CTXVOL Set TX volume ........................................................................................................ 194 9.4 AT+CRXVOL Set RX volume........................................................................................................ 195 9.5 AT+CTXFTR Set TX filter ............................................................................................................. 195 9.6 AT+CRXFTR Set RX filter............................................................................................................. 196 9.7 AT+CVALARM Low voltage Alarm .............................................................................................. 197 9.8 AT+CRIIC Read values from register of IIC device ....................................................................... 198 9.9 AT+CWIIC Write values to register of IIC device .......................................................................... 199 9.10 AT+CVAUXS Set state of the pin named VREG_AUX1 ............................................................... 199 9.11 AT+ CVAUXV Set voltage value of the pin named VREG_AUX1................................................ 200 9.12 AT+CGPIO Set Trigger mode of interrupt GPIO............................................................................ 201 9.13 AT+CGDRT Set the direction of specified GPIO............................................................................ 202 9.14 AT+CGSETV Set the value of specified GPIO............................................................................... 203 9.15 AT+CGGETV Get the value of specified GPIO.............................................................................. 203 9.16 AT+CGISR set interrupt trigger condition and start such interruption............................................ 204

Page 15: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 14

9.17 AT+CADC Read ADC value........................................................................................................... 205 9.18 AT+CMICAMP1 Set value of micamp1 ......................................................................................... 206 9.19 AT+CVLVL Set value of sound level.............................................................................................. 207 9.20 AT+SIDET Digital attenuation of sidetone ..................................................................................... 209 9.21 AT+CECM Enable/Disable Echo Canceller.................................................................................... 210 9.22 AT+CNSM Enable/Disable Noise Suppression ...............................................................................211 9.23 AT+CECSET Adjust the effect for the given echo cancellation mode............................................ 212 9.24 AT+CRIRS Reset RI pin of serial port ............................................................................................ 213 9.25 AT+CSUART Switch UART line mode.......................................................................................... 213 9.26 AT+CMUX Enable the multiplexer over the UART ....................................................................... 214 9.27 AT+CMUXSRVPORT Configure the specific virtual com port to the appropriate service ............ 216 9.28 AT+CDCDMD Set DCD pin mode................................................................................................. 217 9.29 AT+CDCDVL Set DCD pin high-low in GPIO mode .................................................................... 217 9.30 AT+CBC Battery charge ................................................................................................................. 218 9.31 AT+CDTRISRMD Configure the trigger condition for DTR’s interrupt. ....................................... 219 9.32 AT+CDTRISRS Enable/disable the pin of DTR’s awakening function .......................................... 220 9.33 AT+CGFUNC Enable/disable the function for the special GPIO. ..................................................... 221 9.34 AT+CGWHOST Reset GPIO 41 to high level ................................................................................ 222 9.35 AT+CGWISRMD Configure the trigger condition for GPIO43’s................................................... 223 9.36 AT+CKGSWT Switch pins’ function .............................................................................................. 224 9.37 +KEY Keypad result code............................................................................................................... 225 9.38 AT+CUSBSPD Switch USB high or full speed .............................................................................. 226 9.39 AT+CLEDITST Adjust the LED’s intensity ................................................................................... 227 9.40 AT+CADCA Read the value from the second ADC........................................................................ 228 9.41 AT+CAPWRON auto power on setting .......................................................................................... 229 9.42 AT+CAPWROFF auto power off setting ........................................................................................ 230 9.43 AT+CBVTBP Set 800-850 band indicator ...................................................................................... 231 9.44 AT+CRFOP Set the value of RF output power ............................................................................... 232

10 SPI Related Commands ........................................................................................................... 234 10.1 AT+CSPISETCLK SPI clock rate setting ....................................................................................... 234 10.2 AT+CSPISETCS SPI chip select setting ......................................................................................... 235 10.3 AT+CSPISETF SPI clock frequency setting ................................................................................... 236 10.4 AT+CSPISETPARA SPI transfer parameters setting ...................................................................... 237 10.5 AT+CSPIW Write data to SPI ......................................................................................................... 238 10.6 AT+CSPIR Read data from SPI ...................................................................................................... 239

11 Phonebook Related Commands ............................................................................................... 240 11.1 AT+CNUM Subscriber number....................................................................................................... 240 11.2 AT+CPBS Select phonebook memory storage................................................................................ 241 11.3 AT+CPBR Read phonebook entries ................................................................................................ 242 11.4 AT+CPBF Find phonebook entries ................................................................................................. 244 11.5 AT+CPBW Write phonebook entry................................................................................................. 245 11.6 AT+CEMNLIST Set the list of emergency number ........................................................................ 246

12 File System Related Commands .............................................................................................. 247

Page 16: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 15

12.1 AT+FSCD Select directory as current directory.............................................................................. 248 12.2 AT+FSMKDIR Make new directory in current directory ............................................................... 249 12.3 AT+FSRMDIR Delete directory in current directory...................................................................... 250 12.4 AT+FSLS List directories/files in current directory ........................................................................ 250 12.5 AT+FSDEL Delete file in current directory .................................................................................... 252 12.6 AT+FSRENAME Rename file in current directory ........................................................................ 253 12.7 AT+FSATTRI Request file attributes .............................................................................................. 253 12.8 AT+FSMEM Check the size of available memory.......................................................................... 254 12.9 AT+FSLOCA Select storage place .................................................................................................. 255 12.10 AT+FSCOPY Copy an appointed file ............................................................................................. 256

13 File Transmission Related Commands..................................................................................... 258 13.1 AT+CTXFILE Select file transmitted to PC host............................................................................ 258 13.2 AT+CRXFILE Set name of file received from PC host .................................................................. 259 13.3 AT+CMWAIT config the waiting seconds before xmodem start receiving ....................................... 260

14 V24-V25 Commands ............................................................................................................... 262 14.1 AT+IPR Set local baud rate temporarily ......................................................................................... 262 14.2 AT+IPREX Set local baud rate permanently................................................................................... 263 14.3 AT+ICF Set control character framing ............................................................................................ 264 14.4 AT+IFC Set local data flow control................................................................................................. 265 14.5 AT&C Set DCD function mode....................................................................................................... 266 14.6 ATE Enable command echo ............................................................................................................ 266 14.7 AT&V Display current configuration .............................................................................................. 267 14.8 AT&D Set DTR function mode....................................................................................................... 268 14.9 AT&S Set DSR function mode........................................................................................................ 268 14.10 ATV Set result code format mode ................................................................................................... 269

15 Commands for Packet Domain ................................................................................................ 271 15.1 AT+CGDCONT Define PDP context.............................................................................................. 271 15.2 AT+CGDSCONT Define Secondary PDP Context ......................................................................... 273 15.3 AT+CGTFT Define Secondary PDP Context.................................................................................. 274 15.4 AT+CGQREQ Quality of service profile (requested) ..................................................................... 277 15.5 AT+CGEQREQ 3G quality of service profile (requested) .............................................................. 280 15.6 AT+CGQMIN Quality of service profile (minimum acceptable).................................................... 284 15.7 AT+CGEQMIN 3G quality of service profile (minimum acceptable) ............................................ 287 15.8 AT+CGATT Packet domain attach or detach .................................................................................. 291 15.9 AT+CGACT PDP context activate or deactivate............................................................................. 292 15.10 AT+CGDATA Enter data state......................................................................................................... 293 15.11 AT+CGPADDR Show PDP address................................................................................................ 294 15.12 AT+CGCLASS GPRS mobile station class .................................................................................... 295 15.13 AT+CGEREP GPRS event reporting .............................................................................................. 296 15.14 AT+CGREG GPRS network registration status .............................................................................. 298 15.15 AT+CGSMS Select service for MO SMS messages ....................................................................... 299 15.16 AT+CGAUTH Set type of authentication for PDP-IP connections of GPRS.................................. 301

16 TCP/IP Related Commands ..................................................................................................... 303

Page 17: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 16

16.1 AT+CGSOCKCONT Define socket PDP context ........................................................................... 303 16.2 AT+CSOCKSETPN Set active PDP context’s profile number........................................................ 304 16.3 AT+CSOCKAUTH Set type of authentication for PDP-IP conne-ctions of socket ........................ 305 16.4 AT+CGSOCKQREQ Quality of service profile (requested)........................................................... 307 16.5 AT+CGSOCKEQREQ 3G quality of service profile (requested) ................................................... 310 16.6 AT+CGSOCKQMIN Quality of service profile (minimum acceptable) ......................................... 314 16.7 AT+CGSOCKEQMIN 3G quality of service profile (minimum acceptable).................................. 317 16.8 AT+IPADDR Inquire socket PDP address....................................................................................... 322 16.9 AT+NETOPEN Open socket........................................................................................................... 323 16.10 AT+TCPCONNECT Establish TCP connection.............................................................................. 324 16.11 AT+TCPWRITE Send TCP data ..................................................................................................... 325 16.12 AT+UDPSEND Send UDP data ...................................................................................................... 326 16.13 AT+SERVERSTART Startup TCP server........................................................................................ 327 16.14 AT+LISTCLIENT List all of clients’ information........................................................................... 329 16.15 AT+CLOSECLIENT Disconnect specified client ........................................................................... 330 16.16 AT+ACTCLIENT Activate specified client .................................................................................... 331 16.17 AT+NETCLOSE Close socket ........................................................................................................ 331 16.18 AT+CIPHEAD Add an IP head when receiving data ...................................................................... 332 16.19 AT+CIPSRIP Set whether display IP address and port of sender when receiving data................... 333 16.20 AT+CIPCCFG Configure parameters of socket .............................................................................. 334 16.21 AT+CIPOPEN Establish connection in multi-client mode.............................................................. 335 16.22 AT+CIPSEND Send data in multi-client mode ............................................................................... 337 16.23 AT+CIPCLOSE Close connection in Multi-client mode................................................................. 339 16.24 AT+CDNSGIP Query the IP address of given domain name .......................................................... 341 16.25 AT+CDNSGHNAME Query the domain name of given IP address ............................................... 342 16.26 AT+CIPMODE Select TCPIP application mode ............................................................................. 343 16.27 AT+CIPSTAT Statistic the total size of data sent or received.......................................................... 344 16.28 AT+CTCPFIN Wait for TCP_FIN in TCP_FINWAIT2 state.......................................................... 345 16.29 AT+CENDUPPDP Enable duplicate PDP activation ...................................................................... 346 16.30 AT+CTCPKA Set TCP_KEEP_ALIVE parameters........................................................................ 347 16.31 AT+CPING Ping some destination address........................................................................................ 348 16.32 AT+CPINGSTOP Stop an ongoing ping session................................................................................ 349 16.33 AT+CTEUTP Set unknown incoming TCP packet echo ................................................................. 349 16.34 AT+CUPURE Set UDP port unreachable ICMP echo .................................................................... 350 16.35 AT+CINICMPALLOW Preferred ICMP filter ................................................................................ 351 16.36 AT+TCPCLOSE Close the TCP connection ................................................................................... 352 16.37 Information elements related to TCP/IP............................................................................................. 353

17 SIM Application Toolkit (SAT) Commands ............................................................................ 355 17.1 AT+STIN SAT Indication................................................................................................................ 355 17.2 AT+STGI Get SAT information ...................................................................................................... 356 17.3 AT+STGR SAT respond.................................................................................................................. 359 17.4 AT+STK STK Switch...................................................................................................................... 360

18 Internet Service Command ...................................................................................................... 361

Page 18: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 17

18.1 Simple mail transfer protocol service................................................................................................. 361 18.1.1 AT+SMTPSRV SMTP server address and port number .......................................................................... 361 18.1.2 AT+SMTPAUTH SMTP server authentication........................................................................................ 362 18.1.3 AT+SMTPFROM Sender address and name ........................................................................................... 363 18.1.4 AT+SMTPRCPT Recipient address and name (TO/CC/BCC) ................................................................ 365 18.1.5 AT+SMTPSUB E-mail subject................................................................................................................ 366 18.1.6 AT+SMTPBODY E-mail body................................................................................................................ 367 18.1.7 AT+SMTPBCH E-mail body character set .............................................................................................. 368 18.1.8 AT+SMTPFILE Select attachment .......................................................................................................... 369 18.1.9 AT+SMTPSEND Initiate session and send e-mail................................................................................... 371 18.1.10 AT+SMTPSTOP Force to stop sending e-mail ........................................................................................ 372

18.2 Post Office Protocol 3 Service ........................................................................................................... 373 18.2.1 AT+POP3SRV POP3 server and account ................................................................................................ 373 18.2.2 AT+POP3IN Log in POP3 server ............................................................................................................ 374 18.2.3 AT+POP3NUM Get e-mail number and total size................................................................................... 375 18.2.4 AT+POP3LIST List e-mail ID and size ................................................................................................... 376 18.2.5 AT+POP3HDR Get e-mail header ........................................................................................................... 378 18.2.6 AT+POP3GET Get an e-mail from POP3 server ..................................................................................... 379 18.2.7 AT+POP3DEL Mark an e-mail to delete from POP3 server.................................................................... 380 18.2.8 AT+POP3OUT Log out POP3 server ...................................................................................................... 381 18.2.9 AT+POP3STOP Force to stop receiving e-mail/close the session ........................................................... 382 18.2.10 AT+POP3READ Read an e-mail from file system .................................................................................. 383

18.3 File Transfer Protocol Service............................................................................................................ 384 18.3.1 AT+CFTPPORT Set FTP server port ....................................................................................................... 384 18.3.2 AT+CFTPMODE Set FTP mode ............................................................................................................. 384 18.3.3 AT+CFTPTYPE Set FTP type ................................................................................................................. 385 18.3.4 AT+CFTPSERV Set FTP server domain name or IP address................................................................... 386 18.3.5 AT+CFTPUN Set user name for FTP access ........................................................................................... 387 18.3.6 AT+CFTPPW Set user password for FTP access..................................................................................... 388 18.3.7 AT+CFTPGETFILE Get a file from FTP server to EFS.......................................................................... 389 18.3.8 AT+CFTPPUTFILE Put a file in module EFS to FTP server .................................................................. 390 18.3.9 AT+CFTPGET Get a file from FTP server and output it from SIO ......................................................... 392 18.3.10 AT+CFTPPUT Put a file to FTP server ................................................................................................... 393 18.3.11 AT+CFTPLIST List the items in the directory on FTP server ................................................................. 394 18.3.12 Unsolicited FTP Codes (Summary of CME ERROR Codes) ..................................................................... 395

18.4 Hyper Text Transfer Protocol Service ................................................................................................ 396 18.4.1 AT+CHTTPACT Launch a HTTP operation............................................................................................ 396 18.4.2 Unsolicited HTTP codes (summary of CME ERROR codes)..................................................................... 398

18.5 Secure Hyper Text Transfer Protocol Service .................................................................................... 399 18.5.1 AT+CHTTPSSTART Acquire HTTPS protocol stack ............................................................................. 399 18.5.2 AT+CHTTPSSTOP Release HTTPS protocol stack ................................................................................ 399 18.5.3 AT+CHTTPSOPSE Open HTTPS session .............................................................................................. 400 18.5.4 AT+CHTTPSCLSE Close HTTPS session .............................................................................................. 400

Page 19: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 18

18.5.5 AT+CHTTPSSEND Send HTTPS request .............................................................................................. 401 18.5.6 AT+CHTTPSRECV Receive HTTPS response ....................................................................................... 402 18.5.7 Unsolicited HTTPS Codes.......................................................................................................................... 403

18.6 Secure File Transfer Protocol Service ................................................................................................ 404 18.6.1 AT+CFTPSSTART Acquire FTPS protocol stack ................................................................................... 404 18.6.2 AT+CFTPSSTOP Stop FTPS protocol stack ........................................................................................... 404 18.6.3 AT+CFTPSLOGIN Login the FTPS server ............................................................................................. 405 18.6.4 AT+CFTPSLOGOUT Logout the FTPS server ....................................................................................... 405 18.6.5 AT+CFTPSMKD Create a new directory on FTPS server....................................................................... 406 18.6.6 AT+CFTPSRMD Delete a directory on FTPS server .............................................................................. 406 18.6.7 AT+CFTPSDELE Delete a file on FTPS server ...................................................................................... 407 18.6.8 AT+CFTPSCWD Change the current directory on FTPS server ............................................................. 408 18.6.9 AT+CFTPSPWD Get the current directory on FTPS server .................................................................... 409 18.6.10 AT+CFTPSTYPE Set the transfer type on FTPS server .......................................................................... 409 18.6.11 AT+CFTPSLIST List the items in the directory on FTPS server............................................................. 410 18.6.12 AT+CFTPSGETFILE Get a file from FTPS server to EFS ......................................................................411 18.6.13 AT+CFTPSPUTFILE Put a file in module EFS to FTPS server.............................................................. 412 18.6.14 AT+CFTPSGET Get a file from FTPS server to serial port..................................................................... 414 18.6.15 AT+CFTPSPUT Put a file to FTPS server............................................................................................... 415 18.6.16 AT+CFTPSSINGLEIP Set FTPS data socket address type ..................................................................... 416 18.6.17 Unsolicited FTPS Codes............................................................................................................................. 417

18.7 HTTP Time Synchronization Service................................................................................................. 418 18.7.1 AT+CHTPSERV Set HTP server info...................................................................................................... 418 18.7.2 AT+CHTPUPDATE Updating date time using HTP protocol ................................................................. 419 18.7.3 Unsolicited HTP Codes .............................................................................................................................. 420

19 MMS Commands ..................................................................................................................... 421 19.1 AT+CMMSCURL Set the URL of MMS center ............................................................................. 421 19.2 AT+CMMSPROTO Set the protocol parameters and MMS proxy................................................. 422 19.3 AT+CMMSSENDCFG Set the parameters for sending MMS ........................................................ 423 19.4 AT+CMMSEDIT Enter or exit edit mode ....................................................................................... 424 19.5 AT+CMMSDOWN Download the file data or title from UART .................................................... 425 19.6 AT+CMMSDELFILE Delete a file within the editing MMS body ................................................. 427 19.7 AT+CMMSSEND Start MMS sending ........................................................................................... 428 19.8 AT+CMMSRECP Add recipients.................................................................................................... 429 19.9 AT+CMMSCC Add copy-to recipients ........................................................................................... 430 19.10 AT+CMMSBCC Add secret recipients ........................................................................................... 431 19.11 AT+CMMSDELRECP Delete recipients ........................................................................................ 432 19.12 AT+CMMSDELCC Delete copy-to recipients................................................................................ 433 19.13 AT+CMMSDELBCC Delete secret recipients ................................................................................ 434 19.14 AT+CMMSRECV Receive MMS ................................................................................................... 435 19.15 AT+CMMSVIEW View information of MMS in box or memory .................................................. 436 19.16 AT+CMMSREAD read the given file in MMS currently in memory ............................................. 438 19.17 AT+CMMSSNATCH snatch the given file in MMS....................................................................... 439

Page 20: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 19

19.18 AT+CMMSSAVE Save the MMS to a mail box ............................................................................. 440 19.19 AT+CMMSDELETE Delete MMS in the mail box ........................................................................ 441 19.20 AT+CMMSSYSSET Configure MMS transferring parameters ...................................................... 442 19.21 AT+CMMSINCLEN Increase the length of audio/video attachment header .................................. 443 19.22 AT+CMMSUA Set the User-Agent of MMS packet ....................................................................... 444 19.23 AT+CMMSPROFILE Set the User-Agent profile of MMS packet................................................. 445 19.24 Supported Unsolicited Result Codes in MMS.................................................................................... 446

19.24.1 Indication of Sending/Receiving MMS ...................................................................................................... 446 19.24.2 Summary of CME ERROR Codes for MMS.............................................................................................. 447

20 CSCRIPT Commands .............................................................................................................. 449 20.1 AT+CSCRIPTSTART Start running a LUA script file. ................................................................... 449 20.2 AT+CSCRIPTSTOP Stop the current running LUA script.............................................................. 450 20.3 AT+CSCRIPTCL Compile a LUA script file. ................................................................................. 450 20.4 AT+CSCRIPTPASS Set the password for +CSCRIPTCL. ............................................................. 451 20.5 AT+CSCRIPTCMD Send data to the running LUA script. ............................................................. 452 20.6 AT+PRINTDIR Set the value of LUA printdir function. ................................................................ 453 20.7 Unsolicited CSCRIPT codes .............................................................................................................. 454

21 GPS Related Commands.......................................................................................................... 454 21.1 AT+CGPS Start/stop GPS session................................................................................................... 454 21.2 AT+CGPSINFO Get GPS fixed position information..................................................................... 456 21.3 AT+CGPSCOLD Cold start GPS .................................................................................................... 457 21.4 AT+CGPSHOT Hot start GPS......................................................................................................... 458 21.5 AT+CGPSSWITCH Configure output port for NMEA sentence .................................................... 458 21.6 AT+CGPSURL Set AGPS default server URL ............................................................................... 459 21.7 AT+CGPSSSL Set AGPS transport security ................................................................................... 460 21.8 AT+CGPSAUTO Start GPS automatic ........................................................................................... 461 21.9 AT+CGPSNMEA Configure NMEA sentence type ........................................................................ 462 21.10 AT+CGPSMD Configure AGPS MO method................................................................................. 463 21.11 AT+CGPSFTM Start GPS test mode .............................................................................................. 463 21.12 AT+CGPSDEL Delete the GPS information................................................................................... 464 21.13 AT+CGPSNOTIFY LCS respond positioning request .................................................................... 465 21.14 AT+ CGPSXE Enable/disable GPS XTRA function....................................................................... 466 21.15 AT+CGPSXD Download XTRA assistant file ................................................................................ 467 21.16 AT+CGPSXDAUTO Download XTRA assistant file automatically............................................... 468 21.17 AT+CGPSINFOCFG Report GPS NMEA-0183 sentence .............................................................. 468 21.18 Unsolicited XTRA download Codes .................................................................................................. 470 21.19 Cell Location...................................................................................................................................... 470

21.19.1 AT+CASSISTLOC Start/Stop assist location .......................................................................................... 470 21.19.2 AT+ CASSISTLOCTRYTIMES Set retry times...................................................................................... 473 21.19.3 AT+ CASSISTLOCMODE Set assist location mode .............................................................................. 474

22 Voice Mail Related Commands................................................................................................ 475 22.1 AT+CSVM Subscriber number ....................................................................................................... 475 22.2 Indication of Voice Mail..................................................................................................................... 476

Page 21: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 20

23 EONS Related AT commands .................................................................................................. 477 23.1 Indication of EONS............................................................................................................................ 477

24 OTAD Commands ................................................................................................................... 477 24.1 AT+COTADPHONENUMBER modify OTAD phone number ...................................................... 477

25 Result codes ............................................................................................................................. 479 25.1 verbose code and numeric code.......................................................................................................... 479 25.2 Response string of AT+CEER ............................................................................................................ 479

26 AT Commands Samples ........................................................................................................... 483 26.1 SMS commands ................................................................................................................................. 483 26.2 TCP/IP commands.............................................................................................................................. 485

26.2.1 TCP server .................................................................................................................................................. 485 26.2.2 TCP client ................................................................................................................................................... 485 26.2.3 UDP............................................................................................................................................................ 486 26.2.4 Multi client ................................................................................................................................................. 487

26.3 File transmission flow ........................................................................................................................ 487 26.3.1 File transmission to PC host ....................................................................................................................... 487 26.3.2 File received from PC host ......................................................................................................................... 492

26.4 MMS commands ................................................................................................................................ 494 Contact us........................................................................................................................................... 497

Page 22: Simcom Sim5320 Atc en v1.23

1 Introduction

1.1 Scope

The present document describes the AT Command Set for the SIMCom Module:

SIM5320

More information about the SIMCom Module which includes the Software Version information can be retrieved by the command ATI. In this document, a short description, the syntax, the possible setting values and responses, and some examples of AT commands are presented.

Prior to using the Module, please read this document and the Version History to know the difference from the previous document.

In order to implement communication successfully between Customer Application and the Module, it is recommended to use the AT commands in this document, but not to use some commands which are not included in this document.

1.2 References

The present document is based on the following standards:

[1] ETSI GSM 01.04: Abbreviations and acronyms. [2] 3GPP TS 27.005: Use of Data Terminal Equipment – Data Circuit terminating Equipment (DTE –

DCE) interface for Short Message Service (SMS) and Cell Broadcast Service (CBS). [3] 3GPP TS 27.007: AT command set for User Equipment (UE). [4] WAP-224-WTP-20010710-a [5] WAP-230-WSP-20010705-a [6] WAP-209-MMSEncapsulation-20010601-a

1.3 Terms and abbreviations

For the purposes of the present document, the following abbreviations apply:

AT ATtention; the two-character abbreviation is used to start a command line to be sent from TE/DTE to TA/DCE

CSD Circuit Switched Data DCE Data Communication Equipment; Data Circuit terminating Equipment DCS Digital Cellular Network DTE Data Terminal Equipment DTMF Dual Tone Multi–Frequency EDGE Enhanced Data GSM Environment

Page 23: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 22

EGPRS Enhanced General Packet Radio Service GPIO General–Purpose Input/Output GPRS General Packet Radio Service GSM Global System for Mobile communications HSDPA High Speed Downlink Packet Access HSUPA High Speed Uplink Packet Access I2C Inter–Integrated Circuit IMEI International Mobile station Equipment Identity IMSI International Mobile Subscriber Identity ME Mobile Equipment MO Mobile–Originated MS Mobile Station MT Mobile–Terminated; Mobile Termination PCS Personal Communication System PDU Protocol Data Unit PIN Personal Identification Number PUK Personal Unlock Key SIM Subscriber Identity Module SMS Short Message Service SMS–SC Short Message Service – Service Center TA Terminal Adaptor; e.g. a data card (equal to DCE) TE Terminal Equipment; e.g. a computer (equal to DTE) UE User Equipment UMTS Universal Mobile Telecommunications System USIM Universal Subscriber Identity Module WCDMA Wideband Code Division Multiple Access FTP File Transfer Protocol HTTP Hyper Text Transfer Protocol POP3 Post Office Protocol Version 3 POP3 client An client that can receive e-mail from POP3 server over TCP session RTC Real Time Clock SMTP Simple Mail Transfer Protocol SMTP client An client that can transfer text-based e-mail to SMTP server over TCP session URC Unsolicited Result Code MMS Multimedia message system

1.4 Definitions and conventions

1. For the purposes of the present document, the following syntactical definitions apply:

<CR> Carriage return character.

<LF> Linefeed character.

Page 24: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 23

<…> Name enclosed in angle brackets is a syntactical element. Brackets themselves do not appear in the command line.

[…] Optional subparameter of AT command or an optional part of TA information response is enclosed in square brackets. Brackets themselves do not appear in the command line. If subparameter is not given, its value equals to its previous value or the recommended default value.

underline Underlined defined subparameter value is the recommended default setting or factory setting.

2. Document conventions:

♦ Display the examples of AT commands with Italic format. ♦ Not display blank-line between command line and responses or inside the responses. ♦ Generally, the characters <CR> and <LF> are intentionally omitted throughout this document. ♦ If command response is ERROR, not list the ERROR response inside command syntax. NOTE AT commands and responses in figures may be not following above conventions.

3. Special marks for commands or parameters:

SIM PIN – Is the command PIN protected? YES – AT command can be used only when SIM PIN is READY.

NO – AT command can be used when SIM card is absent or SIM PIN validation is pending.

References – Where is the derivation of command? 3GPP TS 27.007 – 3GPP Technical Specification 127 007. V.25ter – ITU–T Recommendation V.25ter. Vendor – The command is supported by SIMCom.

Page 25: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 24

2 AT Interface Synopsis

2.1 Interface settings

Between Customer Application and the Module, standardized RS–232 interface is used for the communication, and default values for the interface settings as following:

115200bps, 8 bit data, no parity, 1 bit stop, no data stream control.

2.2 AT command syntax

The prefix “AT” or “at” (no case sensitive) must be included at the beginning of each command line (except A/ and +++), and the character <CR> is used to finish a command line so as to issue the command line to the Module. It is recommended that a command line only includes a command.

When Customer Application issues a series of AT commands on separate command lines, leave a pause between the preceding and the following command until information responses or result codes are retrieved by Customer Application, for example, “OK” is appeared. This advice avoids too many AT commands are issued at a time without waiting for a response for each command.

In the present document, AT commands are divided into three categories: Basic Command, S Parameter Command, and Extended Command.

1. Basic Command

The format of Basic Command is “AT<x><n>” or “AT&<x><n>”, “<x>” is the command name, and “<n>” is/are the parameter(s) for the basic command, and optional. An example of Basic Command is “ATE<n>”, which informs the TA/DCE whether received characters should be echoed back to the TE/DTE according to the value of “<n>”; “<n>” is optional and a default value will be used if omitted.

2. S Parameter Command

The format of S Parameter Command is “ATS<n>=<m>”, “<n>” is the index of the S–register to set, and “<m>” is the value to assign to it. “<m>” is optional; in this case, the format is “ATS<n>”, and then a default value is assigned.

3. Extended Command

The Extended Command has several formats, as following table list:

Table 2-1: Types of Extended Command

Command Type Syntax Comments

Page 26: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 25

Test Command AT+<NAME>=? Test the existence of the command; give some information about the command subparameters.

Read Command AT+<NAME>? Check the current values of subparameters.

Write Command AT+<NAME>=<…> Set user-definable subparameter values.

Execution Command AT+<NAME> Read non-variable subparameters determined by internal processes.

NOTE The character “+” between the prefix “AT” and command name may be replaced by other character. For example, using “#” or “$”instead of “+”.

2.3 Information responses

If the commands included in the command line are supported by the Module and the subparameters are correct if presented, some information responses will be retrieved by from the Module. Otherwise, the Module will report “ERROR” or “+CME ERROR” or “+CMS ERROR” to Customer Application.

Information responses start and end with <CR><LF>, i.e. the format of information responses is “<CR><LF><response><CR><LF>”. Inside information responses, there may be one or more <CR><LF>. Throughout this document, only the responses are presented, and <CR><LF> are intentionally omitted.

Page 27: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 26

3 General Commands

3.1 ATI Display product identification information

Description The command requests the product information, which consists of manufacturer identification, model identification, revision identification, International Mobile station Equipment Identity (IMEI) and overall capabilities of the product.

SIM PIN References

NO V.25ter

Syntax

Execution Command Responses ATI Manufacturer: <manufacturer>

Model: <model> Revision: <revision> IMEI: <sn> +GCAP: list of <name>s OK

Defined values

<manufacturer> The identification of manufacturer. <model> The identification of model. <revision> The revision identification of firmware. <sn> Serial number identification, which consists of a single line containing IMEI (International Mobile station Equipment Identity) number. <name> List of additional capabilities: +CGSM GSM function is supported +FCLASS FAX function is supported +DS Data compression is supported +ES Synchronous data mode is supported.

Page 28: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 27

Examples

ATI Manufacturer: SIMCOM INCORPORATED Model: SIMCOM_SIM5320 Revision: SIM5320_V1.5 IMEI: 351602000330570 +GCAP: +CGSM,+FCLASS,+DS OK

3.2 AT+CGMI Request manufacturer identification

Description The command requests the manufacturer identification text, which is intended to permit the user of the Module to identify the manufacturer.

SIM PIN References

NO 3GPP TS 27.007

Syntax

Test Command Responses AT+CGMI=? OK

Execution Command Responses AT+CGMI <manufacturer>

OK

Defined values

<manufacturer> The identification of manufacturer.

Examples

AT+CGMI SIMCOM INCORPORATED OK

3.3 AT+CGMM Request model identification

Description

Page 29: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 28

The command requests model identification text, which is intended to permit the user of the Module to identify the specific model.

SIM PIN References

NO 3GPP TS 27.007

Syntax

Test Command Responses AT+CGMM=? OK

Execution Command Responses AT+CGMM <model>

OK

Defined values

<model> The identification of model.

Examples

AT+CGMM SIMCOM_SIM5320 OK

3.4 AT+CGMR Request revision identification

Description The command requests product firmware revision identification text, which is intended to permit the user of the Module to identify the version, revision level, date, and other pertinent information.

SIM PIN References

NO 3GPP TS 27.007

Syntax

Test Command Responses AT+CGMR=? OK

Execution Command Responses AT+CGMR <revision>

OK

Page 30: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 29

Defined values

<revision> The revision identification of firmware.

Examples

AT+CGMR +CGMR: SIM5320_V1.5 OK

3.5 AT+CGSN Request product serial number identification

Description The command requests product serial number identification text, which is intended to permit the user of the Module to identify the individual ME to which it is connected to.

SIM PIN References

NO 3GPP TS 27.007

Syntax

Test Command Responses AT+CGSN=? OK

Execution Command Responses AT+CGSN <sn>

OK

Defined values

<sn> Serial number identification, which consists of a single line containing the IMEI (International Mobile station Equipment Identity) number of the MT.

Examples

AT+CGSN 351602000330570 OK

3.6 AT+CSCS Select TE character set

Description

Page 31: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 30

Write command informs TA which character set <chest> is used by the TE. TA is then able to convert character strings correctly between TE and MT character sets. Read command shows current setting and test command displays conversion schemes implemented in the TA.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CSCS=? +CSCS: (list of supported <chset>s)

OK Read Command Responses AT+CSCS? +CSCS: <chset>

OK Write Command Responses

OK AT+CSCS=<chset>

ERROR Execution Command Responses AT+CSCS Set subparameters as default value:

OK

Defined values

<chest> Character set, the definition as following:

“IRA” International reference alphabet. “GSM” GSM default alphabet; this setting causes easily software flow control (XON

/XOFF) problems. “UCS2” 16-bit universal multiple-octet coded character set; UCS2 character strings are

converted to hexadecimal numbers from 0000 to FFFF.

Examples

AT+CSCS=”IRA” OK AT+CSCS? +CSCS:”IRA” OK

Page 32: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 31

3.7 AT+CIMI Request international mobile subscriber identity

Description Execution command causes the TA to return <IMSI>, which is intended to permit the TE to identify the individual SIM card which is attached to MT.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CIMI=? OK Execution Command Responses AT+CIMI <IMSI>

OK

Defined values

<IMSI> International Mobile Subscriber Identity (string, without double quotes).

Examples

AT+CIMI 460010222028133 OK

3.8 AT+GCAP Request overall capabilities

Description Execution command causes the TA reports a list of additional capabilities.

SIM PIN References

YES V.25ter

Syntax

Test Command Responses AT+GCAP=? OK

Execution Command Responses

Page 33: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 32

AT+GCAP +GCAP: (list of <name>s) OK

Defined values

<name> List of additional capabilities. +CGSM GSM function is supported +FCLASS FAX function is supported +DS Data compression is supported +ES Synchronous data mode is supported.

Examples

AT+GCAP +GCAP:+CGSM,+FCLASS,+DS OK

3.9 AT+CATR Configure URC destination interface

Description The command is used to configure the interface which will be used to output URCs.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CATR=? +CATR: (list of supported <port>s),( list of supported <save>s)

OK Read Command Responses AT+CATR? +CATR: <port>

OK

Write Command Responses OK AT+CATR=<port>[,<save>]

ERROR

Defined values

<port> 0 – all ports 1 – use UART port to output URCs

Page 34: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 33

2 – use MODEM port to output URCs 3 – use ATCOM port to output URCs 4-7 – mapping to 0-3, the port mapping relation can be set by user

<save> 0 – set temporarily 1 – set permanently

Examples

AT+CATR=1,0 OK AT+CATR? +CATR: 1 OK

3.10 A/ Repeat last command

Description The command is used for implement previous AT command repeatedly (except A/), and the return value depends on the last AT command. If A/ is issued to the Module firstly after power on, the response “OK” is only returned. References

V.25ter

Syntax

Execution Command Responses A/ The response the last AT command return

Examples

AT+GCAP +GCAP:+CGSM,+FCLASS,+DS OK A/ +GCAP:+CGSM,+FCLASS,+DS OK

3.11 AT+CFGRI Indicate RI when using URC

Description

Page 35: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 34

The command is used to config whether pulling down the RI pin of UART when URC reported. If <status> is 1, host may be wake up by RI pin. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CFGRI=? +CFGRI: (range of supported <status>s), (range of supported

<save>s) OK

Read Command Responses AT+CFGRI? +CFGRI: <status>, <save>

OK Write Command Responses

OK AT+CFGRI=<status>[,<save>] ERROR Execution Command Responses AT+CFGRI Set <status> = 1,<save> = 0:

OK

Defined values

<status> 0 off 1 on

<save> 0 <status> not saved in nonvolatile memory 1 <status> saved in nonvolatile memory.After it resets, <status> still takes effect.

Examples

AT+CFGRI=? +CFGRI: (0-1),(0-1) OK AT+CFGRI? +CFGRI: 0,0 OK AT+CFGRI=1,1 OK AT+CFGRI OK

Page 36: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 35

4 Call Control Commands and Methods

4.1 AT+CSTA Select type of address

Description Write command is used to select the type of number for further dialing commands (ATD) according to GSM/UMTS specifications. Read command returns the current type of number. Test command returns values supported by the Module as a compound value.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CSTA=? +CSTA:(list of supported <type>s)

OK Read Command Responses AT+CSTA? +CSTA:<type>

OK Write Command Responses

OK AT+CSTA=<type>

ERROR Execution Command Responses AT+CSTA OK

Defined values

<type> Type of address octet in integer format:

145 – when dialling string includes international access code character “+” 161 – national number.The network support for this type is optional 177 – network specific number,ISDN format 129 – otherwise

NOTE Because the type of address is automatically detected on the dial string of dialing command, command AT+CSTA has really no effect.

Examples

Page 37: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 36

AT+CSTA? +CSTA: 129 OK AT+CSTA=145 OK

4.2 AT+CMOD Call mode

Description Write command selects the call mode of further dialing commands (ATD) or for next answering command (ATA). Mode can be either single or alternating. Test command returns values supported by the TA as a compound value.

SIM PIN References

NO 3GPP TS 27.007

Syntax

Test Command Responses AT+CMOD=? +CMOD: (list of supported <mode>s)

OK

Read Command Responses AT+CMOD? +CMOD: <mode>

OK

Write Command Responses OK AT+CMOD=<mode>

ERROR

Execution Command Responses AT+CMOD Set default value:

OK

Defined values

<mode> 0 – single mode(only supported)

NOTE The value of <mode> shall be set to zero after a successfully completed alternating mode call. It shall be set to zero also after a failed answering. The power-on, factory and user resets shall also set the value to zero. This reduces the possibility that alternating mode calls are originated or answered accidentally.

Examples

Page 38: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 37

AT+CMOD? +CMOD: 0 OK AT+CMOD=0 OK

4.3 ATD Dial command

Description The dial command lists characters that may be used in a dialling string for making a call or controlling supplementary services. Note:

1. Support several “P” or “p” in the dtmf string but the valid auto-sending dtmf after characters “P” or “p” should not be more than 29. 2. Auto-sending dtmf after character “P” or “p” should be ASCII character in the set 0-9, *, #.

SIM PIN References

YES V25.ter

Syntax

Execution Commands Responses OK VOICE CALL: BEGIN

Originate a call unsuccessfully: NO CARRIER

ATD<n>[<mgsm>][;]

ERROR

Defined values

<n> String of dialing digits and optionally V.25ter modifiers dialing digits:

0 1 2 3 4 5 6 7 8 9 * # + A B C Following V.25ter modifiers are ignored:

, T P ! W @ <mgsm> String of GSM modifiers:

I Activates CLIR (disables presentation of own phone number to called party) i Deactivates CLIR (enables presentation of own phone number to called party) G Activate Closed User Group explicit invocation for this call only

g Deactivate Closed User Group explicit invocation for this call only <;>

Page 39: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 38

The termination character ";" is mandatory to set up voice calls. It must not be used for data and fax calls. NOTE: If it is a data call, please refer to the result codes table for response at the end of this document.

Examples

ATD10086; OK VOICE CALL:BEGIN

4.4 ATD><mem><n> Originate call from specified memory

Description Originate a call using specified memory and index number.

SIM PIN References

YES V.25ter

Syntax

Execution Commands Responses OK VOICE CALL: BEGIN

ATD><mem><n>[;]

Originate a call unsuccessfully: NO CARRIER

Defined values

<mem> Phonebook storage: (For detailed description of storages see AT+CPBS)

"DC" ME dialed calls list "MC" ME missed (unanswered received) calls list "RC" ME received calls list "SM" SIM phonebook "ME" UE phonebook "FD" SIM fixed dialing phonebook "ON" MSISDN list "LD" Last number dialed phonebook "EN" Emergency numbers

<n> Integer type memory location in the range of locations available in the selected memory, i.e. the index returned by AT+CPBR.

Page 40: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 39

<;> The termination character ";" is mandatory to set up voice calls. It must not be used for data and fax calls.

Examples

ATD>SM3; OK VOICE CALL: BEGIN

4.5 ATD><n> Originate call from active memory (1)

Description Originate a call to specified number.

SIM PIN References

YES V.25ter

Syntax

Execution Commands Responses OK VOICE CALL: BEGIN

ATD><n>[;]

Originate a call unsuccessfully: NO CARRIER

Defined values

<n> Integer type memory location in the range of locations available in the selected memory, i.e. the index number returned by AT+CPBR. <;> The termination character ";" is mandatory to set up voice calls. It must not be used for data and fax calls.

Examples

ATD>2; OK VOICE CALL: BEGIN

Page 41: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 40

4.6 ATD><str> Originate call from active memory (2)

Description Originate a call to specified number.

SIM PIN References

YES V.25ter

Syntax

Execution Commands Responses OK VOICE CALL: BEGIN

ATD><str>[;]

Originate a call unsuccessfully: NO CARRIER

Defined values

<str> String type value, which should equal to an alphanumeric field in at least one phone book entry in the searched memories. <str> formatted as current TE character set specified by AT+CSCS.<str> must be double quoted. <;> The termination character ";" is mandatory to set up voice calls. It must not be used for data and fax calls.

Examples

ATD>”Kobe”; OK VOICE CALL: BEGIN

4.7 ATA Call answer

Description The command is used to make remote station to go off-hook, e.g. answer an incoming call. If there is no an incoming call and entering this command to TA, it will be return “NO CARRIER” to TA.

SIM PIN References

YES V.25ter

Syntax

Page 42: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 41

Execution Commands Responses For voice call: OK VOICE CALL: BEGIN For data call, and TA switches to data mode: CONNECT

ATA

No connection or no incoming call: NO CARRIER

Examples

ATA VOICE CALL: BEGIN OK

4.8 +++ Switch from data mode to command mode

Description The command is only available during a connecting CSD call or PS data call. The +++ character sequence causes the TA to cancel the data flow over the AT interface and switch to Command Mode. This allows to enter AT commands while maintaining the data connection to the remote device. NOTE To prevent the +++ escape sequence from being misinterpreted as data, it must be preceded and followed by a pause of at least 1000 milliseconds, and the interval between two ‘+’ character can’t exceed 900 milliseconds. SIM PIN References

YES V.25ter

Syntax

Execution Command Responses +++ OK

Examples

+++ OK

4.9 ATO Switch from command mode to data mode

Description

Page 43: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 42

ATO is the corresponding command to the +++ escape sequence. When there is a CSD call or a PS data call connected and the TA is in Command Mode, ATO causes the TA to resume the data and takes back to Data Mode.

SIM PIN References

YES V.25ter

Syntax

Execution Command Responses TA/DCE switches to Data Mode from Command Mode: CONNECT

ATO

If connection is not successfully resumed or there is not a connected CSD call: NO CARRIER

Examples

ATO CONNECT

4.10 AT+CVHU Voice hang up control

Description Write command selects whether ATH or “drop DTR” shall cause a voice connection to be disconnected or not. By voice connection is also meant alternating mode calls that are currently in voice mode. SIM PIN References

NO 3GPP TS 27.007

Syntax

Test Command Responses AT+CVHU=? +CVHU: (list of supported <mode>s)

OK

Read Command Responses AT+CVHU? +CVHU: <mode>

OK

Write Command Responses OK AT+CVHU=<mode>

ERROR

Page 44: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 43

Execution Command Responses AT+CVHU Set default value:

OK

Defined values

<mode> 0 – “Drop DTR” ignored but OK response given. ATH disconnects. 1 – “Drop DTR” and ATH ignored but OK response given.

Examples

AT+CVHU=0 OK AT+CVHU? +CVHU: 0 OK

4.11 ATH Disconnect existing call

Description The command is used to disconnect existing voice call. Before using ATH command to hang up a voice call, it must set AT+CVHU=0. Otherwise, ATH command will be ignored and “OK” response is given only. The command is also used to disconnect CSD or PS data call, and in this case it doesn’t depend on the value of AT+CVHU. SIM PIN References

NO V.25ter

Syntax

Execution Command Responses If AT+CVHU=0: VOICE CALL: END: <time> OK

ATH

OK

Defined values

<time> Voice call connection time:

Format – HHMMSS (HH: hour, MM: minute, SS: second)

Page 45: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 44

Examples

AT+CVHU=0 OK ATH VOICE CALL:END:000017 OK

4.12 AT+CHUP Hang up call

Description The command is used to cancel voice calls. If there is no call, it will do nothing but OK response is given. After running AT+CHUP, multiple “VOICE CALL END: ” may be reported which relies on how many calls exist before calling this command. SIM PIN References

NO 3GPP TS 27.007

Syntax

Test Command Responses AT+CHUP=? OK

Execution Command Responses VOICE CALL: END: <time> [… VOICE CALL: END: <time>] OK

AT+CHUP

No call: OK

Defined values

<time> Voice call connection time.

Format – HHMMSS (HH: hour, MM: minute, SS: second)

Examples

AT+CHUP VOICE CALL:END: 000017 OK

Page 46: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 45

4.13 AT+CBST Select bearer service type

Description Write command selects the bearer service <name> with data rate <speed>, and the connection element <ce> to be used when data calls are originated. Values may also be used during mobile terminated data call setup, especially in case of single numbering scheme calls.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CBST=? +CBST: (list of supported <speed>s), (list of supported <name>s),

(list of supported <ce>s) OK

Read Command Responses AT+CBST? +CBST: <speed>,<name>,<ce>

OK Write Command Responses

OK AT+CBST= <speed>[,<name>[,<ce>]] ERROR Execution Command Responses AT+CBST Set default value:

OK

Defined values

<speed> 0 – autobauding(automatic selection of the speed; this setting is possible in case of 3.1

kHz modem and non-transparent service) 7 – 9600 bps (V.32) 12 – 9600 bps (V.34) 14 – 14400 bps(V.34) 16 – 28800 bps(V.34) 17 – 33600 bps(V.34) 39 – 9600 bps(V.120) 43 – 14400 bps(V.120) 48 – 28800 bps(V.120) 51 – 56000 bps(V.120) 71 – 9600 bps(V.110) 75 – 14400 bps(V.110)

Page 47: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 46

80 – 28800 bps(V.110 or X.31 flag stuffing) 81 – 38400 bps(V.110 or X.31 flag stuffing) 83 – 56000 bps(V.110 or X.31 flag stuffing) 84 – 64000 bps(X.31 flag stuffing) 116 – 64000 bps(bit transparent) 134 – 64000 bps(multimedia)

<name> 0 – Asynchronous modem 1 – Synchronous modem 4 – data circuit asynchronous (RDI)

<ce> 0 – transparent

1 – non-transparent NOTE If <speed> is set to 116 or 134, it is necessary that <name> is equal to 1 and <ce> is equal

to 0.

Examples

AT+CBST=0,0,1 OK AT+CBST? +CBST:0,0,1 OK

4.14 AT+CRLP Radio link protocol

Description Radio Link Protocol(RLP) parameters used when non-transparent data calls are originated may be altered with write command. Read command returns current settings for each supported RLP version <verX>. Only RLP parameters applicable to the corresponding <verX> are returned. Test command returns values supported by the TA as a compound value. If ME/TA supports several RLP versions <verX>, the RLP parameter value ranges for each <verX> are returned in a separate line.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CRLP=? +CRLP: (list of supported <iws>s), (list of supported <mws>s),

(list of supported <T1>s), (list of supported <N2>s) [,<ver1>

Page 48: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 47

[,(list of supported <T4>s)]][<CR><LF> +CRLP: (list of supported <iws>s), (list of supported <mws>s), (list of supported <T1>s), (list of supported <N2>s) [,<ver2> [,(list of supported <T4>s)]]

[...]] OK

Read Command Responses AT+CRLP? +CRLP: <iws>, <mws>, <T1>, <N2> [,<ver1> [, <T4>]][<CR>

<LF> +CRLP:<iws>,<mws>,<T1>,<N2>[,<ver2>[,<T4>]] [...]] OK

Write Command Responses OK AT+CRLP=<iws>

[,<mws>[,<T1>[,<N2> [,<ver>[,<T4>]]]]] ERROR

Execution Command Responses AT+CRLP OK

Defined values

<ver>, <verX> RLP version number in integer format, and it can be 0, 1 or 2; when version indication is not present it shall equal 1. <iws> IWF to MS window size. <mws> MS to IWF window size. <T1> Acknowledgement timer. <N2> Retransmission attempts. <T4> Re-sequencing period in integer format. NOTE <T1> and <T4> are in units of 10 ms.

Examples

AT+CRLP? +CRLP:61,61,48,6,0 +CRLP:61,61,48,6,1 +CRLP:240,240,52,6,2 OK

Page 49: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 48

4.15 AT+CR Service reporting control

Description Write command controls whether or not intermediate result code “+CR: <serv>” is returned from the TA to the TE. If enabled, the intermediate result code is transmitted at the point during connect negotiation at which the TA has determined which speed and quality of service will be used, before any error control or data compression reports are transmitted, and before the intermediate result code CONNECT is transmitted.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CR=? +CR: (list of supported <mode>s)

OK

Read Command Responses AT+CR? +CR: <mode>

OK

Write Command Responses AT+CR=<mode> OK

Execution Command Responses AT+CR Set default value:

OK

Defined values

<mode> 0 – disables reporting 1 – enables reporting

<serv> ASYNC asynchronous transparent SYNC synchronous transparent

REL ASYNC asynchronous non-transparent REL sync synchronous non-transparent GPRS [<L2P>] GPRS The optional <L2P> proposes a layer 2 protocol to use between the MT and the TE.

Examples

AT+CR?

Page 50: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 49

+CR:0 OK AT+CR=1 OK

4.16 AT+CEER Extended error report

Description Execution command causes the TA to return the information text <report>, which should offer the user of the TA an extended report of the reason for:

1 the failure in the last unsuccessful call setup(originating or answering) or in-call modification.

2 the last call release. 3 the last unsuccessful GPRS attach or unsuccessful PDP context activation. 4 the last GPRS detach or PDP context deactivation.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CEER=? OK

Execution Command Responses AT+CEER +CEER:<report>

OK

Defined values

<report> Wrong information which is possibly occurred.

Examples

AT+CEER +CEER: Invalid/incomplete number OK

4.17 AT+CRC Cellular result codes

Description

Page 51: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 50

Write command controls whether or not the extended format of incoming call indication or GPRS network request for PDP context activation is used. When enabled, an incoming call is indicated to the TE with unsolicited result code “+CRING: <type>” instead of the normal RING. Test command returns values supported by the TA as a compound value.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CRC=? +CRC: (list of supported <mode>s)

OK

Read Command Responses AT+CRC? +CRC: <mode>

OK

Write Command Responses AT+CRC=<mode> OK

Execution Command Responses AT+CRC Set default value:

OK

Defined values

<mode> 0 – disable extended format

1 – enable extended format <type>

ASYNC asynchronous transparent SYNC synchronous transparent REL ASYNC asynchronous non-transparent REL SYNC synchronous non-transparent FAX facsimile VOICE normal voice

VOICE/XXX voice followed by data(XXX is ASYNC, SYNC, REL ASYNC or REL SYNC)

ALT VOICE/XXX alternating voice/data, voice first ALT XXX/VOICE alternating voice/data, data first ALT FAX/VOICE alternating voice/fax, fax first GPRS GPRS network request for PDP context activation

Examples

Page 52: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 51

AT+CRC=1 OK AT+CRC? +CRC: 1 OK

4.18 AT+VTS DTMF and tone generation

Description The command allows the transmission of DTMF tones and arbitrary tones which cause the Mobile Switching Center (MSC) to transmit tones to a remote subscriber. The command can only be used in voice mode of operation (active voice call). NOTE The END event of voice call will terminate the transmission of tones, and as an operator option, the tone may be ceased after a pre-determined time whether or not tone duration has been reached. SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+VTS=? +VTS: (list of supported<dtmf>s)

OK

Write Command Responses OK AT+VTS=<dtmf>

[,<duration>] AT+VTS=<dtmf-string>

ERROR

Defined values

<dtmf> A single ASCII character in the set 0-9, *, #, A, B, C, D. <duration> Tone duration in 1/10 seconds, from 0 to 255. This is interpreted as a DTMF tone of different duration from that mandated by the AT+VTD command, otherwise, the duration which be set the AT+VTD command will be used for the tone (<duration> is omitted). <dtmf-string> A sequence of ASCII character in the set 0-9, *, #, A, B, C, D, and maximal length of the string is 29. The string must be enclosed in double quotes (“”), and separated by commas between the ASCII characters (e.g. “1,3,5,7,9,*”). Each of the tones with a duration which is set by the AT+VTD command.

Page 53: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 52

Examples

AT+VTS=1 OK AT+VTS=1,20 OK AT+VTS=”1,3,5” OK AT+VTS=? +VTS: (0-9,*,#,A,B,C,D) OK

4.19 AT+CLVL Loudspeaker volume level

Description Write command is used to select the volume of the internal loudspeaker audio output of the device. Test command returns supported values as compound value.

SIM PIN References

NO 3GPP TS 27.007

Syntax

Test Command Responses AT+CLVL=? +CLVL: (list of supported <level>s)

OK

Read Command Responses AT+CLVL? +CLVL: <level>

OK

Write Command Responses OK AT+CLVL=<level>

ERROR

Defined values

<level> Integer type value which represents loudspeaker volume level. The range is from 0 to 8, and 0 represents the lowest loudspeaker volume level, 2 is default factory value. NOTE <level> is nonvolatile, and it is stored when restart.

Examples

AT+CLVL?

Page 54: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 53

+CLVL:2 OK AT+CLVL=3 OK

4.20 AT+VMUTE Speaker mute control

Description The command is used to control the loudspeaker to mute and unmute during a voice call or a video call which is connected. If there is not a connected call, write command can’t be used. When all calls are disconnected, the Module sets the subparameter as 0 automatically. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+VMUTE=? +VMUTE: (list of supported <mode>s)

OK

Read Command Responses AT+VMUTE? +VMUTE: <mode>

OK

Write Command Responses OK AT+VMUTE=<mode>

ERROR

Defined values

<mode> 0 – mute off 1 – mute on

Examples

AT+VMUTE=1 OK AT+VMUTE? +VMUTE:1 OK

Page 55: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 54

4.21 AT+CMUT Microphone mute control

Description The command is used to enable and disable the uplink voice muting during a voice call or a video call which is connected. If there is not a connected call, write command can’t be used. When all calls are disconnected, the Module sets the subparameter as 0 automatically. SIM PIN References

NO 3GPP TS 27.007

Syntax

Test Command Responses AT+CMUT=? +CMUT: (list of supported <mode>s)

OK Read Command Responses AT+CMUT? +CMUT: <mode>

OK

Write Command Responses OK AT+CMUT=<mode>

ERROR

Defined values

<mode> 0 – mute off 1 – mute on

Examples

AT+CMUT=1 OK AT+CMUT? +CMUT: 1 OK

4.22 AT+AUTOANSWER Automatic answer quickly

Description

Page 56: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 55

The command causes the Module to enable and disable automatic answer. If enabled, the Module will answer automatically after the Module receives a call from network and 3 seconds lapse. NOTE 1 .The command is effective on csd call ,voice call and data call even if ATS0=0. 2 .The setting will be effective after restart. 3 .The <port> setting only takes effect on csd call video call. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+AUTOANSWER=? +AUTOANSWER: (list of supported <arg>s), (list of supported

<port>s) OK

Read Command Responses AT+AUTOANSWER? +AUTOANSWER: <arg>,<port>

OK

Write Command Responses AT+AUTOANSWER= <arg>[,<port>]

OK

Defined values

<arg> 0 – disable auto answer

1 – enable auto answer <port>

0 – use current PORT(read for other value, refer to notes) 1 – use UART port to output URCs 2 – use MODEM port to output URCs 3 – use ATCOM port to output URCs

NOTE 1. If subparameter <port> is omitted, the current port will be used. 2. If subparameter <port> is zero, read for current port index, it’s not zero. 3. If subparameter <port> is not zero and auto answer is eanbled, the corresponding port should be opened when data call incoming.

Examples

AT+AUTOANSWER=1,1 OK AT+AUTOANSWER? +AUTOANSWER: 1,1 OK

Page 57: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 56

4.23 ATS0 Automatic answer

Description The S-parameter command controls the automatic answering feature of the Module. If set to 000, automatic answering is disabled, otherwise it causes the Module to answer when the incoming call indication (RING) has occurred the number of times indicated by the specified value; and the setting will not be stored upon power-off, i.e. the default value will be restored after restart. SIM PIN References

YES V.25ter

Syntax

Read Command Responses ATS0? <n>

OK

Write Command Responses ATS0=<n> OK

Defined values

<n> 000 Automatic answering mode is disable. (default value when power-on)

001–255 Enable automatic answering on the ring number specified. NOTE 1.The S-parameter command is effective on voice call and data call.

2.If <n> is set too high, the remote party may hang up before the call can be answered automatically.

3.For voice call and video call, AT+AUTOANSWER is prior to ATS0.

Examples

ATS0? 000 OK ATS0=003 OK

4.24 AT+CALM Alert sound mode

Description

Page 58: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 57

The command is used to select the general alert sound mode of the device. If silent mode is selected then incoming calls will not generate alerting sounds but only the unsolicited indications RING or +CRING. The value of <mode> will be saved to nonvolatile memory after write command is executed.

SIM PIN References

NO 3GPP TS 27.007

Syntax

Test Command Responses AT+CALM=? +CALM: (list of supported <mode>s)

OK Read Command Responses AT+CALM? +CALM: <mode>

OK

Write Command Responses AT+CALM=<mode> OK

Defined values

<mode> 0 – normal mode (factory value) 1 – silent mode; no sound will be generated by the device

Examples

AT+CALM=0 OK AT+CALM? +CALM: 0 OK

4.25 AT+CRSL Ringer sound level

Description The command is used to select the incoming call ringer sound level of the device. The value of <level> will be saved to nonvolatile memory after write command is executed.

SIM PIN References

NO 3GPP TS 27.007

Syntax

Page 59: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 58

Test Command Responses AT+CRSL=? +CRSL: (list of supported <level>s)

OK

Read Command Responses AT+CRSL? +CRSL: <level>

OK

Write Command Responses AT+CRSL=<level> OK

Defined values

<level> Integer type value which represents the incoming call ringer sound level. The range is from 0 to 4, and 0 represents the lowest level, 2 is default factory value. NOTE <level> is nonvolatile, and it is stored when restart.

Examples

AT+CRSL=2 OK AT+CRSL? +CRSL:2 OK

4.26 AT+CSDVC Switch voice channel device

Description The command is used to switch voice channel device. After changing current voice channel device and if there is a connecting voice call, it will use the settings of previous device (loudspeaker volume level, mute state of loudspeaker and microphone, refer to AT+CLVL, AT+VMUTE, and AT+CMUT). NOTE Use AT+CPCM command to enable PCM function and configure the mode that you want before setting AT+CSDVC=4. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CSDVC=? +CSDVC: (list of supported <dev>s),(list of supported <save> s)

OK

Read Command Responses

Page 60: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 59

AT+CSDVC? +CSDVC: <dev> OK

Write Command Responses AT+CSDVC= <dev>[,<save>]

OK

Defined values

<dev> 1 – handset

3 – speaker phone 4 – PCM interface

<save> 0 – temporary voice device setting, after reboot it will be resumed.

1 – permanent voice device setting. NOTE If subparameter <save> is omitted, voice device setting is temporary.

Examples

AT+CSDVC=1 OK AT+CSDVC? +CSDVC:1 OK AT+CSDVC=1,1 OK

4.27 AT+CPTONE Play tone

Description The command is used to play a DTMF tone or complex tone on local voice channel device which is selected by AT+CSDVC.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CPTONE=? +CPTONE: (list of supported <tone>s)

OK

Write Command Responses

Page 61: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 60

AT+CPTONE=<tone> OK [+RXDTMF: <key>] (when <tone> is between 1 and 16)

Defined values

<tone> 0 – Stop the sound tone 1 – DTMF tone for 1 key, duration 100ms 2 – DTMF tone for 2 key, duration 100ms 3 – DTMF tone for 3 key, duration 100ms 4 – DTMF tone for 4 key, duration 100ms 5 – DTMF tone for 5 key, duration 100ms 6 – DTMF tone for 6 key, duration 100ms 7 – DTMF tone for 7 key, duration 100ms 8 – DTMF tone for 8 key, duration 100ms 9 – DTMF tone for 9 key, duration 100ms 10 – DTMF tone for 0 key, duration 100ms 11 – DTMF tone for A key, duration 100ms 12 – DTMF tone for B key, duration 100ms 13 – DTMF tone for C key, duration 100ms 14 – DTMF tone for D key, duration 100ms 15 – DTMF tone for # key, duration 100ms 16 – DTMF tone for * key, duration 100ms 17 – Subscriber busy sound, duration always 18 – Congestion sound, duration always 19 – Error information sound, duration 1330*3ms 20 – Number unobtainable sound, duration 1330*3ms 21 – Authentication failure sound, duration 1330*3ms 22 – Radio path acknowledgement sound, duration 700*1ms 23 – Radio path not available sound, duration 400*4ms 24 – CEPT call waiting sound, duration 4000*2ms 25 – CEPT ringing sound, duration always 26 – CEPT dial tone, duration always

<key> 1 – <tone> value 1 2 – <tone> value 2 3 – <tone> value 3 4 – <tone> value 4 5 – <tone> value 5 6 – <tone> value 6 7 – <tone> value 7 8 – <tone> value 8 9 – <tone> value 9

Page 62: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 61

0 – <tone> value 10 A – <tone> value 11 B – <tone> value 12 C – <tone> value 13 D – <tone> value 14 # – <tone> value 15 * – <tone> value 16

Examples

AT+CPTONE= ? +CPTONE:(0-26) OK AT+CPTONE=17 OK

4.28 AT+CPCM External PCM codec mode configuration

Description The command will enable PCM or disable PCM function. And configure different PCM mode. Because the PCM pins are multiplex on GPIO, it will switch the function between GPIO and PCM. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CPCM=? +CPCM: (list of supported <arg_1>s), (list of supported <arg_2>s)

OK

Read Command Responses AT+CPCM? +CPCM: <arg_1>,<arg_2>

OK

Write Command Responses AT+CPCM=<arg_1>[,<arg_2>]

OK

Defined values

<arg_1> 0 – disable PCM, switch to common GPIOs. 1 – enable PCM, switch to PCM function.

<arg_2> 0 – Auxiliary master PCM, 128K clock and 8K synchronize clock.

Page 63: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 62

1 – Primary master PCM, 2M clock and 8K synchronize clock... 2 – Primary slave PCM, clock provided by external codec.

Examples

AT+CPCM=1 OK AT+CPCM=? +CPCM : (0-1),(0-2) OK AT+CPCM? +CPCM : 1,1 OK

4.29 AT+CPCMFMT Change the PCM format

Description The command allows to change the current PCM format, there are 3 formats currently supported: linear, u-law, a-law

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CPCMFMT=? +CPCMFMT: (list of supported <format>s)

OK

Read Command Responses AT+CPCMFMT? +CPCMFMT: <format>

OK

Write Command Responses OK AT+CPCMFMT=<format>

ERROR

Defined values

<format> 0 u-law 1 a-law 2 linear

Examples

Page 64: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 63

AT+CPCMFMT=? +CPCMFMT: (0-2) OK AT+CPCMFMT? +CPCMFMT: 1 OK AT+CPCMFMT=2 OK

4.30 AT+CPCMREG Control PCM data transfer by diagnostics port

Description The command is used to control PCM data transfer by diagnostics port.First you should set diag- nostics port as data mode by AT+DSWITCH.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CPCMREG=? +CPCMREG: (list of supported <n>s)

OK

Read Command Responses AT+CPCMREG? +CPCMREG: <n>

OK

Write Command Responses OK AT+CPCMREG=<n>

ERROR

Defined values

<n> Switch PCM data transfer by diagnostics port on/off 0 Disable PCM data transfer by diagnostics port 1 Enable PCM data transfer by diagnostics port

Examples

AT+CPCMREG=? +CPCMREG: (0-1) OK AT+CPCMREG?

Page 65: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 64

+CPCMREG: 0 OK AT+CPCMREG=1 OK

4.31 AT+VTD Tone duration

Description This refers to an integer <n> that defines the length of tones emitted as a result of the AT+VTS command. A value different than zero causes a tone of duration <n>/10 seconds.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+VTD=? +VTD: (list of supported <n>s)

OK

Read Command Responses AT+VTD? +VTD: <n>

OK

Write Command Responses AT+VTD=<n> OK

Defined values

<n> Tone duration in integer format, from 0 to 255, and 0 is factory value.

0 Tone duration of every single tone is dependent on the network. 1…255 Tone duration of every single tone in 1/10 seconds.

Examples

AT+VTD=? +VTD: (0-255) OK AT+VTD? +VTD: 0 OK AT+VTD=5 OK

Page 66: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 65

4.32 AT+CODEC Set audio codec mode

Description The command is used to configure audio codec mode.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CODEC=? +CODEC: (list of supported <g_codec>s), (list of supported

<w_codec>s) OK

Read Command Responses AT+CODEC? +CODEC: <g_codec>, <w_codec>

OK

Write Command Responses OK AT+CODEC=<g_codec>,<

w_codec> ERROR

Execution Command Responses AT+CODEC Set default value(63,7)

OK

Defined values

<g_codec> 1~63 – Sum of integers each representing a specific codec mode, default value is 63.

1 – GSM FR 2 – GSM HR

4 – GSM EFR 8 – GSM FR AMR 16 – GSM HR AMR 32 – GSM FR AMR-WB <w_codec> 1~7 – Sum of integers each representing a specific codec mode.,default value is 7.

1 – UMTS AMR 2 – UMTS AMR2 4 – UMTS AMR-WB

Examples

Page 67: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 66

AT+CODEC=? +CODEC: (1-63),( 1-7) OK AT+CODEC? +CODEC: 63,7 OK AT+AUTOCSQ=31,7 OK

4.33 AT+CVOC Get the current vocoder capability in a call

Description

The command is used to get the current vocoder capability in a call. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CVOC=? OK

Execution Command Responses AT+CVOC +CVOC: <voc>,<amr_mode>,<DTX>,<SCR>

OK

Defined values

<voc> 0x100 – AMR codec

0x200 – GSM EFR codec 0x400 – GSM Full rate codec 0x800 – GSM Half rate codec 0x1000000 – AMR-WB vocoder Other values is reserved <amr_mode>

0 – 4.75kbit/s AMR 1 – 5.15kbit/s AMR 2 – 5.9kbit/s AMR 3 – 6.7kbit/s AMR 4 – 7.4kbit/s AMR 5 – 7.95kbit/s AMR

Page 68: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 67

6 – 10.2kbit/s AMR 7 – 12.2kbit/s AMR 8 – 6.60kbit/s AMR-WB 9 – 8.85kbit/s AMR-WB 10 – 12.65kbit/s AMR-WB 11 – 14.25kbit/s AMR-WB 12 – 15.58kbit/s AMR-WB 13 – 18.25kbit/s AMR-WB 14 – 19.58kbit/s AMR-WB 15 – 23.05kbit/s AMR-WB 16 – 23.85kbit/s AMR-WB 17 – undefined

<DTX> 0 – Disable encoder DTX mode 1 – Enable encoder DTX mode

<SCR> 0 – Disable encoder SCR mode 1 – Enable encoder SCR mode

Examples

AT+CVOC +CVOC: 0x200,17,0,0 OK AT+CVOC +CVOC: 0x100,7,0,0 OK

Page 69: Simcom Sim5320 Atc en v1.23

5 SMS Related Commands

5.1 +CMS ERROR Message service failure result code

Description Final result code +CMS ERROR: <err> indicates an error related to mobile equipment or network. The operation is similar to ERROR result code. None of the following commands in the same command line is executed. Neither ERROR nor OK result code shall be returned. ERROR is returned normally when error is related to syntax or invalid parameters. The format of <err> can be either numeric or verbose. This is set with command AT+CMEE. SIM PIN References

--- 3GPP TS 27.005

Syntax

+CMS ERROR: <err>

Defined values

<err> 300 ME failure 301 SMS service of ME reserved 302 Operation not allowed 303 Operation not supported 304 Invalid PDU mode parameter 305 Invalid text mode parameter 310 SIM not inserted 311 SIM PIN required 312 PH-SIM PIN required 313 SIM failure 314 SIM busy 315 SIM wrong 316 SIM PUK required 317 SIM PIN2 required 318 SIM PUK2 required 320 Memory failure 321 Invalid memory index 322 Memory full 330 SMSC address unknown 331 no network service

Page 70: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 69

332 Network timeout 340 NO +CNMA ACK EXPECTED 341 Buffer overflow 342 SMS size more than expected 500 unknown error

Examples

AT+CMGS=02112345678 +CMS ERROR: 304

5.2 AT+CSMS Select message service

Description The command is used to select messaging service <service>.

SIM PIN References

YES 3GPP TS 27.005

Syntax

Test Command Responses AT+CSMS=? +CSMS: (list of supported <service>s)

OK

Read Command Responses AT+CSMS? +CSMS: <service>,<mt>,<mo>,<bm>

OK

Write Command Responses +CSMS: <mt>,<mo>,<bm> OK

ERROR

AT+CSMS=<service>

+CMS ERROR: <err>

Defined values

<service> 0 – SMS at command is compatible with GSM phase 2. 1 – SMS at command is compatible with GSM phase 2+.

<mt> Mobile terminated messages:

0 – type not supported. 1 – type supported.

Page 71: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 70

<mo> Mobile originated messages:

0 – type not supported. 1 – type supported.

<bm> Broadcast type messages:

0 – type not supported. 1 – type supported.

Examples

AT+CSMS=0 +CSMS:1,1,1 OK AT+CSMS? +CSMS:0,1,1,1 OK AT+CSMS=? +CSMS:(0-1) OK

5.3 AT+CPMS Preferred message storage

Description The command is used to select memory storages <mem1>, <mem2> and <mem3> to be used for reading, writing, etc.

SIM PIN References

YES 3GPP TS 27.005

Syntax

Test Command Responses AT+CPMS=? +CPMS: (list of supported <mem1>s), (list of supported

<mem2>s), (list of supported <mem3>s) OK

Read Command Responses +CPMS:<mem1>,<used1>,<total1>,<mem2>,<used2>,<total2>, <mem3>,<used3>,<total3> OK

ERROR

AT+CPMS?

+CMS ERROR: <err>

Page 72: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 71

Write Command Responses +CPMS: <used1>,<total1>,<used2>,<total2>,<used3>,<total3> OK

ERROR

AT+CPMS=<mem1> [,<mem2>[,<mem3>]]

+CMS ERROR: <err>

Defined values

<mem1> String type, memory from which messages are read and deleted (commands List Messages AT+CMGL, Read Message AT+CMGR and Delete Message AT+CMGD).

“ME” and “MT” FLASH message storage “SM” SIM message storage “SR” Status report storage

<mem2> String type, memory to which writing and sending operations are made (commands Send Message from Storage AT+CMSS and Write Message to Memory AT+CMGW).

“ME” and “MT” FLASH message storage “SM” SIM message storage “SR” Status report storage

<mem3> String type, memory to which received SMS is preferred to be stored (unless forwarded directly to TE; refer command New Message Indications AT+CNMI).

“ME” FLASH message storage “SM” SIM message storage

<usedX> Integer type, number of messages currently in <memX>. <totalX> Integer type, total number of message locations in <memX>.

Examples

AT+CPMS=? +CPMS: ("ME","MT","SM","SR"),("ME","MT","SM","SR"),("ME",,"SM") OK AT+CPMS? +CPMS:"ME", 0, 23,"ME", 0, 23,"ME", 0, 23 OK AT+CPMS="SM","SM","SM" +CPMS:3,40,3,40,3,40 OK

Page 73: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 72

5.4 AT+CMGF Select SMS message format

Description The command is used to specify the input and output format of the short messages.

SIM PIN References

YES 3GPP TS 27.005

Syntax

Test Command Responses AT+CMGF=? +CMGF: (list of supported <mode>s)

OK

Read Command Responses AT+CMGF? +CMGF: <mode>

OK

Write Command Responses AT+CMGF=<mode> OK

Execution Command Responses AT+CMGF Set default value (<mode>=0):

OK

Defined values

<mode> 0 – PDU mode 1 – Text mode

Examples

AT+CMGF? +CMGF: 0 OK AT+CMGF=? +CMGF: (0-1) OK AT+CMGF=1 OK

Page 74: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 73

5.5 AT+CSCA SMS service centre address

Description The command is used to update the SMSC address, through which mobile originated SMS are transmitted.

SIM PIN References

YES 3GPP TS 27.005

Syntax

Test Command Responses AT+CSCA=? OK

Read Command Responses AT+CSCA? +CSCA: <sca>,<tosca>

OK

Write Command Responses AT+CSCA=<sca>[,<tosca>] OK

Defined values

<sca> Service Center Address, value field in string format, BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set (refer to command AT+CSCS), type of address given by <tosca>. <tosca> SC address Type-of-Address octet in integer format, when first character of <sca> is + (IRA 43) default is 145, otherwise default is 129.

Examples

AT+CSCA="+8613012345678" OK AT+CSCA? +CSCA: "+8613010314500", 145 OK

5.6 AT+CSCB Select cell broadcast message indication

Description

Page 75: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 74

The test command returns the supported <operation>s as a compound value. The read command displays the accepted message types. Depending on the <operation> parameter, the write command adds or deletes the message types accepted. SIM PIN References

YES 3GPP TS 27.005

Syntax

Test Command Responses +CSCB: (list of supported <mode>s) OK

AT+CSCB=?

ERROR

Read Command Responses +CSCB: <mode>,<mids>,<dcss> OK

AT+CSCB?

ERROR

Write Command Responses OK

ERROR

AT+CSCB= <mode>[,<mides>[,<dcss>]]

+CMS ERROR: <err>

Defined values

<mode> 0 – message types specified in <mids> and <dcss> are accepted. 1 – message types specified in <mids> and <dcss> are not accepted.

<mides> String type; all different possible combinations of CBM message identifiers. <dcss> String type; all different possible combinations of CBM data coding schemes(default is empty string)

Examples

AT+CSCB=? +CSCB: (0-1) OK AT+CSCB=0,”15-17,50,86”,”” OK

Page 76: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 75

5.7 AT+CSDH Show text mode parameters

Description The command is used to control whether detailed header information is shown in text mode result codes.

SIM PIN References

YES 3GPP TS 27.005

Syntax

Test Command Responses AT+CSDH=? +CSDH: (list of supported <show>s)

OK

Read Command Responses AT+CSDH? +CSDH: <show>

OK

Write Command Responses AT+CSDH=<show> OK

Execution Command Responses AT+CSDH Set default value (<show>=0):

OK

Defined values

<show> 0 – do not show header values defined in commands AT+CSCA and AT+CSMP (<sca>,

<tosca>, <fo>, <vp>, <pid> and <dcs>) nor <length>, <toda> or <tooa> in +CMT, AT+CMGL, AT+CMGR result codes for SMS-DELIVERs and SMS-SUBMITs in text mode; for SMS-COMMANDs in AT+CMGR result code, do not show <pid>, <mn>, <da>, <toda>, <length> or <data>

1 – show the values in result codes

Examples

AT+CSDH? +CSDH: 0 OK AT+CSDH=1 OK

Page 77: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 76

5.8 AT+CNMA New message acknowledgement to ME/TA

Description The command confirms successful receipt of a new message (SMS-DELIVER or SMS-STATUSREPORT) routed directly to the TE. If ME does not receive acknowledgement within required time (network timeout), it will send RP-ERROR to the network. NOTE The execute / write command shall only be used when AT+CSMS parameter <service> equals 1 (= phase 2+) and appropriate URC has been issued by the module, i.e.: <+CMT> for <mt>=2 incoming message classes 0, 1, 3 and none; <+CMT> for <mt>=3 incoming message classes 0 and 3; <+CDS> for <ds>=1. SIM PIN References

YES 3GPP TS 27.005

Syntax

Test Command Responses AT+CNMA=? if text mode(AT+CMGF=1):

OK if PDU mode (AT+CMGF=0): +CNMA: (list of supported <n>s) OK

Write Command Responses OK

ERROR

AT+CNMA=<n>

+CMS ERROR: <err>

Execution Command Responses OK

ERROR

AT+CNMA

+CMS ERROR: <err>

Defined values

<n> Parameter required only for PDU mode. 0 – Command operates similarly as execution command in text mode. 1 – Send positive (RP-ACK) acknowledgement to the network. Accepted only in PDU

mode. 2 – Send negative (RP-ERROR) acknowledgement to the network. Accepted only in PDU

mode.

Page 78: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 77

Examples

AT+CNMI=1,2,0,0,0 OK +CMT:”1380022xxxx”,”02/04/03,11 :06 :38”,129,7,0<CR><LF> Testing (receive new short message) AT+CNMA(send ACK to the network) OK AT+CNMA +CMS ERROR:340 (the second time return error, it needs ACK only once)

5.9 AT+CNMI New message indications to TE

Description The command is used to select the procedure how receiving of new messages from the network is indicated to the TE when TE is active, e.g. DTR signal is ON. If TE is inactive (e.g. DTR signal is OFF). If set <mt>=2, <mt>=3 or <ds>=1, make sure <mode>=1, otherwise it will return error.

SIM PIN References

YES 3GPP TS 27.005

Syntax

Test Command Responses AT+CNMI=? +CNMI: (list of supported <mode>s),(list of supported <mt>s),(list

of supported <bm>s),(list of supported <ds>s),(list of supported <bfr>s) OK

Read Command Responses AT+CNMI? +CNMI: <mode>,<mt>,<bm>,<ds>,<bfr>

OK

Write Command Responses OK

ERROR

AT+CNMI=<mode>[,<mt>[,<bm>[,<ds> [,<bfr>]]]]

+CMS ERROR: <err>

Execution Command Responses AT+CNMI Set default value:

OK

Page 79: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 78

Defined values

<mode> 0 – Buffer unsolicited result codes in the TA. If TA result code buffer is full, indications

can be buffered in some other place or the oldest indications may be discarded and replaced with the new received indications.

1 – Discard indication and reject new received message unsolicited result codes when TA-TE link is reserved (e.g. in on-line data mode). Otherwise forward them directly to the TE.

2 – Buffer unsolicited result codes in the TA when TA-TE link is reserved (e.g. in on-line data mode) and flush them to the TE after reservation. Otherwise forward them directly to the TE.

<mt> The rules for storing received SMS depend on its data coding scheme, preferred memory storage (AT+CPMS) setting and this value:

0 – No SMS-DELIVER indications are routed to the TE. 1 – If SMS-DELIVER is stored into ME/TA, indication of the memory location is routed

to the TE using unsolicited result code: +CMTI: <mem3>,<index>. 2 – SMS-DELIVERs (except class 2 messages and messages in the message waiting

indication group (store message)) are routed directly to the TE using unsolicited result code: +CMT:[<alpha>],<length><CR><LF><pdu> (PDU mode enabled); or +CMT:<oa>,[<alpha>],<scts>[,<tooa>,<fo>,<pid>,<dcs>,<sca>,<tosca>,<length>] <CR> <LF><data> (text mode enabled, about parameters in italics, refer command Show Text Mode Parameters AT+CSDH).

3 – Class 3 SMS-DELIVERs are routed directly to TE using unsolicited result codes defined in <mt>=2. Messages of other data coding schemes result in indication as defined in <mt>=1.

<bm> The rules for storing received CBMs depend on its data coding scheme, the setting of Select CBM Types (AT+CSCB) and this value:

0 – No CBM indications are routed to the TE. 2 – New CBMs are routed directly to the TE using unsolicited result code:

+CBM: <length><CR><LF><pdu> (PDU mode enabled); or +CBM: <sn>,<mid>,<dcs>,<page>,<pages><CR><LF><data> (text mode enabled)

<ds> 0 – No SMS-STATUS-REPORTs are routed to the TE. 1 – SMS-STATUS-REPORTs are routed to the TE using unsolicited result code:

+CDS: <length><CR><LF><pdu> (PDU mode enabled); or +CDS: <fo>,<mr>,[<ra>],[<tora>],<scts>,<dt>,<st> (text mode enabled)

2 – If SMS-STATUS-REPORT is stored into ME/TA, indication of the memory location is routed to the TE using unsolicited result code: +CDSI: <mem3>,<index>.

Page 80: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 79

<bfr> 0 – TA buffer of unsolicited result codes defined within this command is flushed to the TE

when <mode> 1 to 3 is entered (OK response shall be given before flushing the codes).1 – TA buffer of unsolicited result codes defined within this command is cleared when

<mode> 1 to 3 is entered.

Examples

AT+CNMI? +CNMI: 0,0,0,0,0 OK AT+CNMI=? +CNMI: (0,1,2),(0,1,2,3),(0,2),(0,1,2),(0,1) OK AT+CNMI=2,1 (unsolicited result codes after received messages.) OK

5.10 AT+CMGL List SMS messages from preferred store

Description The command returns messages with status value <stat> from message storage <mem1> to the TE. If the status of the message is 'received unread', the status in the storage changes to 'received read'. SIM PIN References

YES 3GPP TS 27.005

Syntax

Test Command Responses AT+CMGL=? +CMGL: (list of supported <stat>s)

OK

Write Command Responses If text mode (AT+CMGF=1), command successful and SMS-SUBMITs and/or SMS-DELIVERs: +CMGL:<index>,<stat>,<oa>/<da>,[<alpha>],[<scts>][,<tooa>/<toda>,<length>] <CR><LF><data>[<CR><LF> +CMGL:<index>,<stat>,<da>/<oa>,[<alpha>],[<scts>][,<tooa>/<toda>,<length>]<CR><LF><data>[...]] OK

AT+CMGL=<stat>

If text mode (AT+CMGF=1), command successful and SMS- STATUS-REPORTs: +CMGL:<index>,<stat>,<fo>,<mr>,[<ra>],[<tora>],<scts>,<dt>,<s

Page 81: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 80

t>[<CR><LF> +CMGL:<index>,<stat>,<fo>,<mr>,[<ra>],[<tora>],<scts>,<dt>,<st>[...]] OK

If text mode (AT+CMGF=1), command successful and SMS- COMMANDs: +CMGL: <index>,<stat>,<fo>,<ct>[<CR><LF> +CMGL: <index>,<stat>,<fo>,<ct>[...]] OK

If text mode (AT+CMGF=1), command successful and CBM storage: +CMGL:<index>,<stat>,<sn>,<mid>,<page>,<pages> <CR><LF><data>[<CR><LF> +CMGL:<index>,<stat>,<sn>,<mid>,<page>,<pages> <CR><LF><data>[...]] OK

If PDU mode (AT+CMGF=0) and Command successful: +CMGL:<index>,<stat>,[<alpha>],<length><CR><LF><pdu>[<CR><LF> +CMGL:<index>,<stat>,[<alpha>],<length><CR><LF><pdu> […]] OK

+CMS ERROR: <err>

Defined values

<stat> 1. Text Mode:

"REC UNREAD" received unread message (i.e. new message) "REC READ" received read message "STO UNSENT" stored unsent message "STO SENT" stored sent message "ALL" all messages

2. PDU Mode: 0 – received unread message (i.e. new message) 1 – received read message 2 – stored unsent message 3 – stored sent message 4 – all messages

<index> Integer type; value in the range of location numbers supported by the associated memory and start with zero.

Page 82: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 81

<oa> Originating-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <tooa>. <da> Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <toda>. <alpha> String type alphanumeric representation of <da> or <oa> corresponding to the entry found in MT phonebook; implementation of this feature is manufacturer specific; used character set should be the one selected with command Select TE Character Set AT+CSCS. <scts> TP-Service-Centre-Time-Stamp in time-string format (refer <dt>). <tooa> TP-Originating-Address, Type-of-Address octet in integer format. (default refer <toda>). <toda> TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is + (IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255. <length> Integer type value indicating in the text mode (AT+CMGF=1) the length of the message body <data> in characters; or in PDU mode (AT+CMGF=0), the length of the actual TP data unit in octets. (i.e. the RP layer SMSC address octets are not counted in the length) <data> In the case of SMS: TP-User-Data in text mode responses; format:

1. If <dcs> indicates that GSM 7 bit default alphabet is used and <fo> indicates that TP-User-Data-Header-Indication is not set:

a. If TE character set other than "HEX": ME/TA converts GSM alphabet into current TE character set.

b. If TE character set is "HEX": ME/TA converts each 7-bit character of GSM 7 bit default alphabet into two IRA character long hexadecimal number. (e.g. character Π (GSM 7 bit default alphabet 23) is presented as 17 (IRA 49 and 55))

2. If <dcs> indicates that 8-bit or UCS2 data coding scheme is used, or <fo> indicates that TP-User-Data-Header-Indication is set: ME/TA converts each 8-bit octet into two IRA character long hexadecimal number. (e.g. octet with integer value 42 is presented to TE as two characters 2A (IRA 50 and 65))

3. If <dcs> indicates that GSM 7 bit default alphabet is used: a. If TE character set other than "HEX":ME/TA converts GSM alphabet into current TE

character set. b. If TE character set is "HEX": ME/TA converts each 7-bit character of the GSM 7 bit

default alphabet into two IRA character long hexadecimal number. 4. If <dcs> indicates that 8-bit or UCS2 data coding scheme is used: ME/TA converts each

8-bit octet into two IRA character long hexadecimal number.

Page 83: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 82

<fo> Depending on the Command or result code: first octet of GSM 03.40 SMS-DELIVER, SMS-SUBMIT (default 17), SMS-STATUS-REPORT, or SMS-COMMAND (default 2) in integer format. SMS status report is supported under text mode if <fo> is set to 49. <mr> Message Reference GSM 03.40 TP-Message-Reference in integer format. <ra> Recipient Address GSM 03.40 TP-Recipient-Address Address-Value field in string format;BCD numbers (or GSM default alphabet characters) are converted to characters of the currently selected TE character set(refer to command AT+CSCS);type of address given by <tora> <tora> Type of Recipient Address GSM 04.11 TP-Recipient-Address Type-of-Address octet in integer format (default refer <toda>) <dt> Discharge Time GSM 03.40 TP-Discharge-Time in time-string format:”yy/MM/dd,hh:mm:ss+zz”,where characters indicate year (two last digits),month,day,hour,minutes,seconds and time zone. <st> Status GSM 03.40 TP-Status in integer format 0…255 <ct> Command Type GSM 03.40 TP-Command-Type in integer format 0…255 <sn> Serial Number GSM 03.41 CBM Serial Number in integer format <mid> Message Identifier GSM 03.41 CBM Message Identifier in integer format <page> Page Parameter GSM 03.41 CBM Page Parameter bits 4-7 in integer format <pages> Page Parameter GSM 03.41 CBM Page Parameter bits 0-3 in integer format <pdu> In the case of SMS: SC address followed by TPDU in hexadecimal format: ME/TA converts each octet of TP data unit into two IRA character long hexadecimal number. (e.g. octet with integer value 42 is presented to TE as two characters 2A (IRA 50 and 65)).

Page 84: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 83

Examples

AT+CMGL=? +CMGL: ("REC UNREAD","REC READ","STO UNSENT","STO SENT","ALL") OK AT+CMGL="ALL" +CMGL: 1,"STO UNSENT","+10011",,,145,4 Hello World OK

5.11 AT+CMGR Read message

Description The command returns message with location value <index> from message storage <mem1> to the TE.

SIM PIN References

YES 3GPP TS 27.005

Syntax

Test Command Responses AT+CMGR=? OK

Write Command Responses If text mode (AT+CMGF=1), command successful and SMS- DELIVER: +CMGR: <stat>,<oa>,[<alpha>],<scts>[,<tooa>,<fo>,<pid>,<dcs>, <sca>, <tosca>, <length>]<CR><LF><data> OK

If text mode (AT+CMGF=1), command successful and SMS- SUBMIT: +CMGR:<stat>,<da>,[<alpha>][,<toda>,<fo>,<pid>,<dcs>,[<vp>], <sca>, <tosca>,<length>]<CR><LF><data> OK

If text mode (AT+CMGF=1), command successful and SMS- STATUS-REPORT: +CMGR: <stat>,<fo>,<mr>,[<ra>],[<tora>],<scts>,<dt>,<st> OK

AT+CMGR=<index>

If text mode (AT+CMGF=1), command successful and SMS- COMMAND: +CMGR:<stat>,<fo>,<ct>[,<pid>,[<mn>],[<da>],[<toda>],<length>]<CR><LF><data>

Page 85: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 84

OK

If text mode (AT+CMGF=1), command successful and CBM storage: +CMGR:<stat>,<sn>,<mid>,<dcs>,<page>,<pages><CR><LF><data> OK

If PDU mode (AT+CMGF=0) and Command successful: +CMGR:<stat>,[<alpha>],<length><CR><LF><pdu> OK

+CMS ERROR: <err>

Defined values

<index> Integer type; value in the range of location numbers supported by the associated memory and start with zero. <stat>

1.Text Mode: "REC UNREAD" received unread message (i.e. new message) "REC READ" received read message "STO UNSENT" stored unsent message "STO SENT" stored sent message

2. PDU Mode: 0 – received unread message (i.e. new message) 1 – received read message. 2 – stored unsent message. 3 – stored sent message

<oa> Originating-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <tooa>. <alpha> String type alphanumeric representation of <da> or <oa> corresponding to the entry found in MT phonebook; implementation of this feature is manufacturer specific; used character set should be the one selected with command Select TE Character Set AT+CSCS. <scts> TP-Service-Centre-Time-Stamp in time-string format (refer <dt>). <tooa> TP-Originating-Address, Type-of-Address octet in integer format. (default refer <toda>). <fo> Depending on the Command or result code: first octet of GSM 03.40 SMS-DELIVER, SMS-SUBMIT (default 17), SMS-STATUS-REPORT, or SMS-COMMAND (default 2) in integer format. SMS status report is supported under text mode if <fo> is set to 49.

Page 86: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 85

<pid> Protocol Identifier GSM 03.40 TP-Protocol-Identifier in integer format 0…255 <dcs> Depending on the command or result code: SMS Data Coding Scheme (default 0), or Cell Broadcast Data Coding Scheme in integer format. <sca> RP SC address Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <tosca>. <tosca> RP SC address Type-of-Address octet in integer format (default refer <toda>). <length> Integer type value indicating in the text mode (AT+CMGF=1) the length of the message body <data> > (or <cdata>) in characters; or in PDU mode (AT+CMGF=0), the length of the actual TP data unit in octets. (i.e. the RP layer SMSC address octets are not counted in the length). <data> In the case of SMS: TP-User-Data in text mode responses; format:

1 – If <dcs> indicates that GSM 7 bit default alphabet is used and <fo> indicates that TP-User-Data-Header-Indication is not set:

a. If TE character set other than "HEX": ME/TA converts GSM alphabet into current TE character set.

b. If TE character set is "HEX": ME/TA converts each 7-bit character of GSM 7 bit default alphabet into two IRA character long hexadecimal number. (e.g. character Π (GSM 7 bit default alphabet 23) is presented as 17 (IRA 49 and 55)).

2 – If <dcs> indicates that 8-bit or UCS2 data coding scheme is used, or <fo> indicates that TP-User-Data-Header-Indication is set: ME/TA converts each 8-bit octet into two IRA character long hexadecimal number. (e.g. octet with integer value 42 is presented to TE as two characters 2A (IRA 50 and 65)).

3 – If <dcs> indicates that GSM 7 bit default alphabet is used: a. If TE character set other than "HEX":ME/TA converts GSM alphabet into current

TE character set. b. If TE character set is "HEX": ME/TA converts each 7-bit character of the GSM 7

bit default alphabet into two IRA character long hexadecimal number. 4 – If <dcs> indicates that 8-bit or UCS2 data coding scheme is used: ME/TA converts

each 8-bit octet into two IRA character long hexadecimal number. <da> Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <toda>. <toda> TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is +

Page 87: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 86

(IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255. <vp> Depending on SMS-SUBMIT <fo> setting: TP-Validity-Period either in integer format (default 167) or in time-string format (refer <dt>). <mr> Message Reference GSM 03.40 TP-Message-Reference in integer format. <ra> Recipient Address GSM 03.40 TP-Recipient-Address Address-Value field in string format;BCD numbers(or GSM default alphabet characters) are converted to characters of the currently selected TE character set(refer to command AT+CSCS);type of address given by <tora> <tora> Type of Recipient Address GSM 04.11 TP-Recipient-Address Type-of-Address octet in integer format (default refer <toda>) <dt> Discharge Time GSM 03.40 TP-Discharge-Time in time-string format:”yy/MM/dd,hh:mm:ss+zz”,where characters indicate year (two last digits),month,day,hour,minutes,seconds and time zone. <st> Status GSM 03.40 TP-Status in integer format 0…255 <ct> Command Type GSM 03.40 TP-Command-Type in integer format 0…255 <mn> Message Number GSM 03.40 TP-Message-Number in integer format <sn> Serial Number GSM 03.41 CBM Serial Number in integer format <mid> Message Identifier GSM 03.41 CBM Message Identifier in integer format <page> Page Parameter GSM 03.41 CBM Page Parameter bits 4-7 in integer format <pages> Page parameter GSM 03.41 CBM Page Parameter bits 0-3 in integer format <pdu>

Page 88: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 87

In the case of SMS: SC address followed by TPDU in hexadecimal format: ME/TA converts each octet of TP data unit into two IRA character long hexadecimal number. (e.g. octet with integer value 42 is presented to TE as two characters 2A (IRA 50 and 65)).

Examples

AT+CMGR=1 +CMGR: "STO UNSENT","+10011",,145,17,0,0,167,"+8613800100500",145,4 Hello World OK

5.12 AT+CMGS Send message

Description The command is used to send message from a TE to the network (SMS-SUBMIT).

SIM PIN References

YES 3GPP TS 27.005

Syntax

Test Command Responses AT+CMGS=? OK

Write Command Responses If text mode (AT+CMGF=1) and sending successfully: +CMGS: <mr> OK If PDU mode(AT+CMGF=0) and sending successfully: +CMGS: <mr> OK

If sending fails: ERROR

If text mode (AT+CMGF=1): AT+CMGS=<da>[,<toda>]<CR>Text is entered. <CTRL-Z/ESC> If PDU mode(AT+CMGF=0): AT+CMGS=<length><CR> PDU is entered <CTRL-Z/ESC>

If sending fails: +CMS ERROR: <err>

Defined values

<da> Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <toda>. <toda>

Page 89: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 88

TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is + (IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255. <length> integer type value indicating in the text mode (AT+CMGF=1) the length of the message body <data> > (or <cdata>) in characters; or in PDU mode (AT+CMGF=0), the length of the actual TP data unit in octets. (i.e. the RP layer SMSC address octets are not counted in the length) <mr> Message Reference GSM 03.40 TP-Message-Reference in integer format. NOTE In text mode, the maximum length of an SMS depends on the used coding scheme: It is 160 characters if the 7 bit GSM coding scheme is used.

Examples

AT+CMGS="13012832788"<CR>(TEXT MODE) > ABCD<ctrl-Z/ESC> +CMGS: 46 OK

5.13 AT+CMSS Send message from storage

Description The command is used to send message with location value <index> from preferred message storage <mem2> to the network (SMS-SUBMIT or SMS-COMMAND).

SIM PIN References

YES 3GPP TS 27.005

Syntax

Test Command Responses AT+CMSS=? OK

Write Command Responses +CMSS: <mr> OK

ERROR

AT+CMSS= <index> [,<da>[,<toda>]]

If sending fails: +CMS ERROR: <err>

Defined values

<index>

Page 90: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 89

Integer type; value in the range of location numbers supported by the associated memory and start with zero. <da> Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <toda>. <mr> Message Reference GSM 03.40 TP-Message-Reference in integer format. <toda> TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is + (IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255. NOTE In text mode, the maximum length of an SMS depends on the used coding scheme: It is 160 characters if the 7 bit GSM coding scheme is used.

Examples

AT+CMSS=3 +CMSS: 0 OK AT+CMSS=3,"13012345678" +CMSS: 55 OK

5.14 AT+CMGW Write message to memory

Description The command is used to store message (either SMS-DELIVER or SMS-SUBMIT) to memory storage <mem2>.

SIM PIN References

YES 3GPP TS 27.005

Syntax

Test Command Responses AT+CMGW=? OK

Write Command Responses If text mode(AT+CMGF=1): AT+CMGW=<oa>/<da>[,<t

+CMGW: <index> OK

Page 91: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 90

ERROR ooa>/<toda>[,<stat>]]<CR>Text is entered. <CTRL-Z/ESC> If PDU mode(AT+CMGF=0): AT+CMGW=<length>[,<stat>]<CR>PDU is entered. <CTRL-Z/ESC>

+CMS ERROR: <err>

Defined values

<index> Integer type; value in the range of location numbers supported by the associated memory and start with zero. <oa> Originating-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <tooa>. <tooa> TP-Originating-Address, Type-of-Address octet in integer format. (default refer <toda>). <da> Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <toda>. <toda> TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is + (IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255. <length> Integer type value indicating in the text mode (AT+CMGF=1) the length of the message body <data> > (or <cdata>) in characters; or in PDU mode (AT+CMGF=0), the length of the actual TP data unit in octets. (i.e. the RP layer SMSC address octets are not counted in the length). <stat>

1. Text Mode: "STO UNSENT" stored unsent message "STO SENT" stored sent message

2. PDU Mode: 2 – stored unsent message 3 – stored sent message

NOTE In text mode, the maximum length of an SMS depends on the used coding scheme: It is 160 characters if the 7 bit GSM coding scheme is used.

Examples

Page 92: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 91

AT+CMGW="13012832788" <CR> (TEXT MODE) ABCD<ctrl-Z/ESC> +CMGW:1 OK

5.15 AT+CMGD Delete message

Description The command is used to delete message from preferred message storage <mem1> location <index>. If <delflag> is present and not set to 0 then the ME shall ignore <index> and follow the rules for <delflag> shown below. SIM PIN References

YES 3GPP TS 27.005

Syntax

Test Command Responses AT+CMGD=? +CMGD: (list of supported <index>s)[,(list of supported

<delflag>s)] OK

Write Command Responses OK

ERROR

AT+CMGD= <index>[,<delflag>]

+CMS ERROR: <err>

Defined values

<index> Integer type; value in the range of location numbers supported by the associated memory and start with zero. <delflag>

0 – (or omitted) Delete the message specified in <index>. 1 – Delete all read messages from preferred message storage, leaving unread messages and

stored mobile originated messages (whether sent or not) untouched. 2 – Delete all read messages from preferred message storage and sent mobile originated

messages, leaving unread messages and unsent mobile originated messages untouched.3 – Delete all read messages from preferred message storage, sent and unsent mobile

originated messages leaving unread messages untouched. 4 – Delete all messages from preferred message storage including unread messages.

NOTE If set <delflag>=1, 2, 3 or 4, <index> is omitted, such as AT+CMGD=,1.

Page 93: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 92

Examples

AT+CMGD=1 OK

5.16 AT+CSMP Set text mode parameters

Description The command is used to select values for additional parameters needed when SM is sent to the network or placed in storage when text format message mode is selected.

SIM PIN References

YES 3GPP TS 27.005

Syntax

Test Command Responses AT+CSMP=? OK

Read Command Responses AT+CSMP? +CSMP: <fo>,<vp>,<pid>,<dcs>

OK

Write Command Responses AT+CSMP= [<fo>[,<vp>[,<pid>[,<dcs>]]]]

OK

Defined values

<fo> Depending on the Command or result code: first octet of GSM 03.40 SMS-DELIVER, SMS-SUBMIT (default 17), SMS-STATUS-REPORT, or SMS-COMMAND (default 2) in integer format. SMS status report is supported under text mode if <fo> is set to 49. <vp> Depending on SMS-SUBMIT <fo> setting: GSM 03.40,TP-Validity-Period either in integer format (default 167), in time-string format, or if is supported, in enhanced format (hexadecimal coded string with quotes), (<vp> is in range 0... 255). <pid> GSM 03.40 TP-Protocol-Identifier in integer format (default 0). <dcs> GSM 03.38 SMS Data Coding Scheme (default 0), or Cell Broadcast Data Coding Scheme in integer format depending on the command or result code.

Examples

Page 94: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 93

AT+CSMP=17,23,64,244 OK

5.17 AT+CMGRO Read message only

Description The command returns message with location value <index> from message storage <mem1> to the TE, but the message’s status don’t change.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMGRO=? OK

Write Command Responses If text mode(AT+CMGF=1),command successful and SMS-DELIVER: +CMGRO:<stat>,<oa>,[<alpha>],<scts>[,<tooa>,<fo>,<pid>,<dcs>, <sca>,<tosca>,<length>]<CR><LF><data> OK

If text mode (AT+CMGF=1),command successful and SMS-SUBMIT: +CMGRO:<stat>,<da>,[<alpha>][,<toda>,<fo>,<pid>,<dcs>,[<vp>], <sca>,<tosca>,<length>]<CR><LF><data> OK

If text mode(AT+CMGF=1),command successful and SMS- STATUS-REPORT: +CMGRO: <stat>,<fo>,<mr>,[<ra>],[<tora>],<scts>,<dt>,<st> OK

If text mode (AT+CMGF=1),command successful and SMS-COMMAND: +CMGRO:<stat>,<fo>,<ct>[,<pid>,[<mn>],[<da>],[<toda>],<length><CR><LF><data>] OK

AT+CMGRO=<index>

If text mode(AT+CMGF=1), command successful and CBM storage: +CMGRO:<stat>,<sn>,<mid>,<dcs>,<page>,<pages><CR><LF><data>

Page 95: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 94

OK

If PDU mode (AT+CMGF=0) and command successful: +CMGR: <stat>,[<alpha>],<length><CR><LF><pdu> OK

Otherwise: +CMS ERROR: <err>

Defined values

Refer to command AT+CMGR.

Examples

AT+CMGRO=6 +CMGRO:"REC READ","+8613917787249",,"06/07/10,12:09:38+32",145,4,0,0,"+86138002105 00",145,4 abcd OK

5.18 AT+CMGMT Change message status

Description The command is used to change the message status. If the status is unread, it will be changed read. Other statuses don’t change.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMGMT=? OK

Write Command Responses OK

ERROR

AT+CMGMT=<index>

+CMS ERROR: <err>

Defined values

<index> Integer type; value in the range of location numbers supported by the associated memory and start with zero.

Page 96: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 95

Examples

AT+CMGMT=1 OK

5.19 AT+CMVP Set message valid period

Description This command is used to set valid period for sending short message.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMVP=? +CMVP: (list of supported <vp>s)

OK

Read Command Responses AT+CMVP? +CMVP:<vp>

OK

Write Command Responses OK

ERROR

AT+CMVP=<vp>

+CMS ERROR: <err>

Defined values

<vp> Validity period value:

0 to 143 (<vp>+1) x 5 minutes (up to 12 hours) 144 to 167 12 hours + (<vp>-143) x 30 minutes 168 to 196 (<vp>-166) x 1 day 197 to 255 (<vp>-192) x 1 week

Examples

AT+CMVP=167 OK AT+CMVP? +CMVP: 167 OK

Page 97: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 96

5.20 AT+CMGRD Read and delete message

Description The command is used to read message, and delete the message at the same time. It integrate AT+CMGR and AT+CMGD, but it doesn’t change the message status.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMGRD=? OK

Write Command Responses If text mode(AT+CMGF=1),command successful and SMS-DE-LIVER: +CMGRD:<stat>,<oa>,[<alpha>],<scts>[,<tooa>,<fo>,<pid>,<dcs>, <sca>,<tosca>,<length>]<CR><LF><data> OK

If text mode(AT+CMGF=1),command successful and SMS-SU- BMIT: +CMGRD:<stat>,<da>,[<alpha>][,<toda>,<fo>,<pid>,<dcs>,[<vp>], <sca>,<tosca>,<length>]<CR><LF><data> OK

If text mode(AT+CMGF=1),command successful and SMS-STA-TUS- REPORT: +CMGRD: <stat>,<fo>,<mr>,[<ra>],[<tora>],<scts>,<dt>,<st> OK

If text mode(AT+CMGF=1),command successful and SMS-CO-MMAND: +CMGRD:<stat>,<fo>,<ct>[,<pid>,[<mn>],[<da>],[<toda>],<length><CR><LF><data>] OK

If text mode(AT+CMGF=1),command successful and CBM sto-rage: +CMGRD:<stat>,<sn>,<mid>,<dcs>,<page>,<pages><CR><LF><data> OK

AT+CMGRD=<index>

If PDU mode(AT+CMGF=0) and command successful: +CMGRD: <stat>,[<alpha>],<length><CR><LF><pdu> OK

Page 98: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 97

ERROR

+CMS ERROR: <err>

Defined values

Refer to command AT+CMGR.

Examples

AT+CMGRD=6 +CMGRD:"REC READ","+8613917787249",,"06/07/10,12:09:38+32",145,4,0,0, "+86138002105 00",145,4 How do you do OK

5.21 AT+CMGSO Send message quickly

Description The command is used to send message from a TE to the network (SMS-SUBMIT). But it’s different from AT+CMGS. This command only need one time input, and wait for “>” needless.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMGSO=? OK

Write Command Responses +CMGSO: <mr> OK

ERROR

If text mode (AT+CMGF=1): AT+CMGSO=<da>[,<toda>], <text> If PDU mode (AT+CMGF=0): AT+CMGSO=<length>,<pducontent>

+CMS ERROR: <err>

Defined values

<mr> Message Reference GSM 03.40 TP-Message-Reference in integer format. <da>

Page 99: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 98

Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <toda>. <length> Integer type value indicating in the text mode (AT+CMGF=1) the length of the message body <data> > (or <cdata>) in characters; or in PDU mode (AT+CMGF=0), the length of the actual TP data unit in octets. (i.e. the RP layer SMSC address octets are not counted in the length). <toda> TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is + (IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255. <text> Content of message. <pducontent> Content of message. NOTE In text mode, the maximum length of an SMS depends on the used coding scheme: It is 160 characters if the 7 bit GSM coding scheme is used.

Examples

AT+CMGSO="10086","YECX" +CMGSO: 128 OK

5.22 AT+CMGWO Write message to memory quickly

Description The command stores message (either SMS-DELIVER or SMS-SUBMIT) to memory storage <mem2>. But it’s different from AT+CMGW. This command only need one time input, and wait for “>” needless.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMGWO=? OK

Write Command Responses +CMGWO: <index> OK

If text mode (AT+CMGF=1): AT+CMGWO=<da>[,<toda>],<text>

ERROR

Page 100: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 99

If PDU mode (AT+CMGF=0): AT+CMGWO=<length>,<pducontent>

+CMS ERROR: <err>

Defined values

<index> Integer type; value in the range of location numbers supported by the associated memory and start with zero. <da> Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <toda>. <toda> TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is + (IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255. <text> Content of message. <pducontent> Content of message.

Examples

AT+CMGWO="13012832788","ABCD" +CMGWO: 1 OK

5.23 AT+CMGSEX Send message

Description The command is used to send message from a TE to the network (SMS-SUBMIT).

SIM PIN References

YES 3GPP TS 27.005

Syntax

Test Command Responses AT+CMGSEX=? OK

Write Command Responses

Page 101: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 100

If text mode (AT+CMGF=1) and sending successfully: +CMGSEX: <mr> OK If PDU mode(AT+CMGF=0) and sending successfully: +CMGSEX: <mr> OK

If sending fails: ERROR

If text mode (AT+CMGF=1): AT+CMGSEX=<da>[,<toda>][,<mr>, <msg_seg>, <msg_total>]<CR>Text is entered. <CTRL-Z/ESC> If PDU mode(AT+CMGF=0): AT+CMGSEX=<length><CR> PDU is entered <CTRL-Z/ESC>

If sending fails: +CMS ERROR: <err>

Defined values

<da> Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <toda>. <toda> TP-Destination-Address, Type-of-Address octet in integer format. (When first character of <da> is + (IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255. <length> Integer type value indicating in the text mode (AT+CMGF=1) the length of the message body <data> > (or <cdata>) in characters; or in PDU mode (AT+CMGF=0), the length of the actual TP data unit in octets. (i.e. the RP layer SMSC address octets are not counted in the length) <mr> Message Reference GSM 03.40 TP-Message-Reference in integer format. <msg_seg> The segment number for long sms <msg_total> The total number of the segments for long sms. It’s range is from 2 to 255. NOTE In text mode, the maximum length of an SMS depends on the used coding scheme: For single SMS, it is 160 characters if the 7 bit GSM coding scheme is used; For multiple long sms, it is 153 characters if the 7 bit GSM coding scheme is used.

Examples

AT+CMGSEX="13012832788", 190, 1, 2<CR>(TEXT MODE) > ABCD<ctrl-Z/ESC> +CMGSEX: 190 OK AT+CMGSEX="13012832788", 190, 2, 2<CR>(TEXT MODE)

Page 102: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 101

> EFGH<ctrl-Z/ESC> +CMGSEX: 190 OK

5.24 AT+CMGENREF Generate a new message reference

Description The command is used to generate a new message reference which can be used by AT+CMGSEX. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMGENREF=? OK

Execute Command Responses AT+CMGENREF +CMGENREF: <mr>

OK

Defined values

<mr> Message Reference GSM 03.40 TP-Message-Reference in integer format.

Examples

AT+CMGENREF=? OK AT+CMGENREF +CMGENREF:190 OK

Page 103: Simcom Sim5320 Atc en v1.23

6 Network Service Related Commands

6.1 AT+CREG Network registration

Description Write command controls the presentation of an unsolicited result code +CREG: <stat> when <n>=1 and there is a change in the ME network registration status. Read command returns the status of result code presentation and an integer <stat> which shows whether the network has currently indicated the registration of the ME. SIM PIN References

NO 3GPP TS 27.007

Syntax

Test Command Responses AT+CREG=? +CREG: (list of supported <n>s)

OK

Read Command Responses +CREG: <n>,<stat>[,<lac>,<ci>] OK

ERROR

AT+CREG?

+CME ERROR: <err>

Write Command Responses OK

ERROR

AT+CREG =<n>

+CME ERROR: <err>

Execution Command Responses AT+CREG Set default value(<n>=0):

OK

Defined values

<n> 0 – disable network registration unsolicited result code 1 – enable network registration unsolicited result code +CREG: <stat> 2 – there is a change in the ME network registration status or a change of the network cell: +CREG: <stat>[,<lac>,<ci>]

Page 104: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 103

<stat> 0 – not registered, ME is not currently searching a new operator to register to 1 – registered, home network 2 – not registered, but ME is currently searching a new operator to register to 3 – registration denied 4 – unknown 5 – registered, roaming

<lac> Two byte location area code in hexadecimal format(e.g.”00C3” equals 193 in decimal). <ci> Two byte cell ID in hexadecimal format.

Examples

AT+CREG? +CREG: 0,1 OK

6.2 AT+COPS Operator selection

Description Write command forces an attempt to select and register the GSM/UMTS network operator. <mode> is used to select whether the selection is done automatically by the ME or is forced by this command to operator <oper> (it shall be given in format <format>). If the selected operator is not available, no other operator shall be selected (except <mode>=4). The selected operator name format shall apply to further read commands (AT+COPS?) also. <mode>=2 forces an attempt to deregister from the network. The selected mode affects to all further network registration (e.g. after <mode>=2, ME shall be unregistered until <mode>=0 or 1 is selected). Read command returns the current mode and the currently selected operator. If no operator is selected, <format> and <oper> are omitted. Test command returns a list of quadruplets, each representing an operator present in the network. Quadruplet consists of an integer indicating the availability of the operator <stat>, long and short alphanumeric format of the name of the operator, and numeric format representation of the operator. Any of the formats may be unavailable and should then be an empty field. The list of operators shall be in order: home network, networks referenced in SIM, and other networks. It is recommended (although optional) that after the operator list TA returns lists of supported <mode>s and <format>s. These lists shall be delimited from the operator list by two commas. When executing AT+COPS=? , any input from serial port will stop this command. SIM PIN References

NO 3GPP TS 27.007

Syntax

Page 105: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 104

Test Command Responses +COPS: [list of supported (<stat>,long alphanumeric <oper> ,short alphanumeric <oper>,numeric <oper>[,< AcT>])s] [,,(list of supported <mode>s),(list of supported <format>s)] OK

ERROR

AT+COPS=?

+CME ERROR: <err>

Read Command Responses +COPS: <mode>[,<format>,<oper>[,< AcT>]] OK

ERROR

AT+COPS?

+CME ERROR: <err>

Write Command Responses OK

ERROR

AT+COPS=<mode>[,<format>[,<oper>[,< AcT>]]]

+CME ERROR: <err>

Execution Command Responses AT+COPS OK

Defined values

<mode> 0 – automatic 1 – manual 2 – force deregister 3 – set only <format> 4 – manual/automatic 5 – manual,but do not modify the network selection mode(e.g GSM,WCDMA) after

module resets. <format>

0 – long format alphanumeric <oper> 1 – short format alphanumeric <oper> 2 – numeric <oper>

<oper> string type, <format> indicates if the format is alphanumeric or numeric. <stat>

0 – unknown 1 – available 2 – current 3 – forbidden

<AcT>

Page 106: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 105

Access technology selected 0 – GSM 1 – GSM Compact 2 – UTRAN

Examples

AT+COPS? +COPS: 0,0,"China Mobile Com",0 OK AT+COPS=? +COPS:(2,"China Unicom","Unicom","46001",0),(3,"China Mobile Com","DGTMPT", "46000",0),,(0,1,2,3,4),(0,1,2) OK

6.3 AT+CLCK Facility lock

Description The command is used to lock, unlock or interrogate a ME or a network facility <fac>. Password is normally needed to do such actions. When querying the status of a network service (<mode>=2) the response line for 'not active' case (<status>=0) should be returned only if service is not active for any <class>.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses +CLCK: (list of supported <fac>s) OK

AT+CLCK=?

+CME ERROR: <err>

Write Command Responses OK

When <mode>=2 and command successful: +CLCK:<status>[,<class1>[<CR><LF> +CLCK: <status>,<class2> [...]] OK

AT+CLCK=<fac>,<mode> [,<passwd>[,<class>]]

+CME ERROR: <err>

Defined values

Page 107: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 106

<fac> "PF" lock Phone to the very First inserted SIM card or USIM card "SC" lock SIM card or USIM card "AO" Barr All Outgoing Calls "OI" Barr Outgoing International Calls "OX" Barr Outgoing International Calls except to Home Country "AI" Barr All Incoming Calls "IR" Barr Incoming Calls when roaming outside the home country "AB" All Barring services (only for <mode>=0) "AG" All outGoing barring services (only for <mode>=0) "AC" All inComing barring services (only for <mode>=0) "FD" SIM fixed dialing memory feature "PN" Network Personalization "PU" network subset Personalization "PP" service Provider Personalization "PC" Corporate Personalization

<mode> 0 – unlock 1 – lock 2 – query status

<status> 0 – not active 1 – active

<passwd> Password. <classX> It is a sum of integers each representing a class of information (default 7):

1 – voice (telephony) 2 – data (refers to all bearer services) 4 – fax (facsimile services) 8 – short message service 16 – data circuit sync 32 – data circuit async 64 – dedicated packet access 128 – dedicated PAD access 255 – The value 255 covers all classes

Examples

AT+CLCK="SC",2 +CLCK: 0 OK

Page 108: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 107

6.4 AT+CPWD Change password

Description Write command sets a new password for the facility lock function defined by command Facility Lock AT+CLCK. Test command returns a list of pairs which present the available facilities and the maximum length of their password.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses +CPWD: (list of supported (<fac>,<pwdlength>)s) OK

AT+CPWD=?

+CME ERROR: <err>

Write Command Responses OK AT+CPWD=

<fac>,<oldpwd>,<newpwd> +CME ERROR: <err>

Defined values

<fac> Refer Facility Lock +CLCK for other values:

"SC" SIM or USIM PIN1 "P2" SIM or USIM PIN2 "AB" All Barring services "AC" All inComing barring services (only for <mode>=0) "AG" All outGoing barring services (only for <mode>=0) "AI" Barr All Incoming Calls "AO" Barr All Outgoing Calls "IR" Barr Incoming Calls when roaming outside the home country "OI" Barr Outgoing International Calls "OX" Barr Outgoing International Calls except to Home Country

<oldpwd> String type, it shall be the same as password specified for the facility from the ME user interface or with command Change Password AT+CPWD. <newpwd> String type, it is the new password; maximum length of password can be determined with <pwdlength>. <pwdlength>

Page 109: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 108

Integer type, max length of password.

Examples

AT+CPWD=? +CPWD: ("AB",4),("AC",4),("AG",4),("AI",4),("AO",4),("IR",4),("OI",4),("OX",4),( "SC",8),("P2",8) OK

6.5 AT+CLIP Calling line identification presentation

Description The command refers to the GSM/UMTS supplementary service CLIP (Calling Line Identification Presentation) that enables a called subscriber to get the calling line identity (CLI) of the calling party when receiving a mobile terminated call. Write command enables or disables the presentation of the CLI at the TE. It has no effect on the execution of the supplementary service CLIP in the network. When the presentation of the CLI at the TE is enabled (and calling subscriber allows), +CLIP: <number>,<type>,,[,[<alpha>][,<CLI validity>]] response is returned after every RING (or +CRING: <type>; refer sub clause "Cellular result codes +CRC") result code sent from TA to TE. It is manufacturer specific if this response is used when normal voice call is answered.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CLIP=? +CLIP: (list of supported <n>s)

OK

Read Command Responses +CLIP: <n>,<m> OK

ERROR

AT+CLIP?

+CME ERROR: <err>

Write Command Responses OK

ERROR

AT+CLIP=<n>

+CME ERROR: <err>

Execution Command Responses

Page 110: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 109

AT+CLIP Set default value(<n>=0,<m>=0): OK

Defined values

<n> Parameter sets/shows the result code presentation status in the TA:

0 – disable 1 – enable

<m> 0 – CLIP not provisioned 1 – CLIP provisioned 2 – unknown (e.g. no network, etc.)

<number> String type phone number of calling address in format specified by <type>. <type> Type of address octet in integer format;

128 – Restricted number type includes unknown type and format 145 – International number type 161 – national number.The network support for this type is optional 177 – network specific number,ISDN format

129 – Otherwise <alpha> String type alphanumeric representation of <number> corresponding to the entry found in phone book. <CLI validity>

0 – CLI valid 1 – CLI has been withheld by the originator 2 – CLI is not available due to interworking problems or limitations of originating

network

Examples

AT+CLIP=1 OK RING (with incoming call) +CLIP: "02152063113",128,,,"gongsi",0

6.6 AT+CLIR Calling line identification restriction

Description

Page 111: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 110

The command refers to CLIR-service that allows a calling subscriber to enable or disable the presentation of the CLI to the called party when originating a call. Write command overrides the CLIR subscription (default is restricted or allowed) when temporary mode is provisioned as a default adjustment for all following outgoing calls. This adjustment can be revoked by using the opposite command.. If this command is used by a subscriber without provision of CLIR in permanent mode the network will act. Read command gives the default adjustment for all outgoing calls (given in <n>), and also triggers an interrogation of the provision status of the CLIR service (given in <m>). Test command returns values supported as a compound value.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CLIR =? +CLIR: (list of supported <n>s)

OK

Read Command Responses +CLIR: <n>,<m> OK

ERROR

AT+CLIR?

+CME ERROR: <err>

Write Command Responses OK

ERROR

AT+CLIR =<n>

+CME ERROR: <err>

Defined values

<n> 0 – presentation indicator is used according to the subscription of the CLIR service 1 – CLIR invocation 2 – CLIR suppression

<m> 0 – CLIR not provisioned 1 – CLIR provisioned in permanent mode 2 – unknown (e.g. no network, etc.) 3 – CLIR temporary mode presentation restricted 4 – CLIR temporary mode presentation allowed

Examples

Page 112: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 111

AT+CLIR=? +CLIR:(0-2) OK

6.7 AT+COLP Connected line identification presentation

Description The command refers to the GSM/UMTS supplementary service COLP(Connected Line Identification Presentation) that enables a calling subscriber to get the connected line identity (COL) of the called party after setting up a mobile originated call. The command enables or disables the presentation of the COL at the TE. It has no effect on the execution of the supplementary service COLR in the network. When enabled (and called subscriber allows), +COLP:<number>, <type> [,<subaddr>, <satype> [,<alpha>]] intermediate result code is returned from TA to TE before any +CR responses. It is manufacturer specific if this response is used when normal voice call is established. When the AT+COLP=1 is set, any data input immediately after the launching of “ATDXXX;” will stop the execution of the ATD command, which may cancel the establishing of the call. SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+COLP=? +COLP: (list of supported <n>s)

OK

Read Command Responses +COLP: <n>,<m> OK

ERROR

AT+COLP?

+CME ERROR: <err>

Write Command Responses OK

ERROR

AT+COLP =<n>

+CME ERROR: <err>

Execution Command Responses AT+COLP Set default value(<n>=0, <m>=0):

OK

Defined values

Page 113: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 112

<n> Parameter sets/shows the result code presentation status in the TA:

0 – disable 1 – enable

<m> 0 – COLP not provisioned 1 – COLP provisioned 2 – unknown (e.g. no network, etc.)

Examples

AT+COLP? +COLP: 1,0 OK ATD10086; VOICE CALL: BEGIN +COLP: "10086",129,,, OK

6.8 AT+CCUG Closed user group

Description The command allows control of the Closed User Group supplementary service. Set command enables the served subscriber to select a CUG index, to suppress the Outgoing Access (OA), and to suppress the preferential CUG.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CCUG=? OK

Read Command Responses +CCUG: <n>,<index>,<info> OK

ERROR

AT+CCUG?

+CME ERROR: <err>

Write Command Responses AT+CCUG= OK

Page 114: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 113

ERROR <n>[,<index>[,<info>]]

+CME ERROR: <err>

Execution Command Responses AT+CCUG Set default value:

OK

Defined values

<n> 0 – disable CUG temporary mode 1 – enable CUG temporary mode

<index> 0...9 – CUG index 10 – no index (preferred CUG taken from subscriber data)

<info> 0 – no information 1 – suppress OA 2 – suppress preferential CUG 3 – suppress OA and preferential CUG

Examples

AT+CCUG? +CCUG: 0,0,0 OK

6.9 AT+CCFC Call forwarding number and conditions

Description The command allows control of the call forwarding supplementary service. Registration, erasure, activation, deactivation, and status query are supported.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CCFC=? +CCFC: (list of supported <reason>s)

OK

Write Command Responses AT+CCFC=<reason>,<mode When <mode>=2 and command successful:

Page 115: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 114

+CCFC: <status>,<class1>[,<number>,<type> [,<subaddr>,<satype>[,<time>]]][<CR><LF> +CCFC: <status>,<class2>[,<number>,<type> [,<subaddr>,<satype>[,<time>]]][...]] OK

ERROR

>[,<number>[,<type>[,<class>[,<subaddr>[,<satype>[,<time> ]]]]]]

+CME ERROR:<err>

Defined values

<reason> 0 – unconditional 1 – mobile busy 2 – no reply 3 – not reachable 4 – all call forwarding 5 – all conditional call forwarding

<mode> 0 – disable 1 – enable 2 – query status 3 – registration 4 – erasure

<number> String type phone number of forwarding address in format specified by <type>. <type> Type of address octet in integer format:

145 – dialing string <number> includes international access code character ‘+’ 129 – otherwise

<subaddr> String type sub address of format specified by <satype>. <satype> Type of sub address octet in integer format, default 128. <classX> It is a sum of integers each representing a class of information (default 7):

1 – voice (telephony) 2 – data (refers to all bearer services) 4 – fax (facsimile services) 16 – data circuit sync 32 – data circuit async 64 – dedicated packet access 128 – dedicated PAD access

Page 116: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 115

255 – The value 255 covers all classes <time> 1...30 – when "no reply" is enabled or queried, this gives the time in seconds to wait before call is forwarded, default value 20. <status>

0 – not active 1 – active

Examples

AT+CCFC=? +CCFC: (0,1,2,3,4,5) OK AT+CCFC=0,2 +CCFC: 0,255 OK

6.10 AT+CCWA Call waiting

Description The command allows control of the Call Waiting supplementary service. Activation, deactivation and status query are supported. When querying the status of a network service (<mode>=2) the response line for 'not active' case (<status>=0) should be returned only if service is not active for any <class>. Parameter <n> is used to disable/enable the presentation of an unsolicited result code +CCWA: <number>,<type>,<class> to the TE when call waiting service is enabled. Command should be abortable when network is interrogated.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CCWA=? +CCWA: (list of supported <n>s)

OK

Read Command Responses AT+CCWA? +CCWA: <n>

OK

Write Command Responses AT+CCWA= <n>[,<mode>[,<class>]]

When <mode>=2 and command successful: +CCWA:<status>,<class>[<CR><LF> +CCWA: <status>, <class>[...]]

Page 117: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 116

OK

ERROR

+CME ERROR: <err>

Execution Command Responses AT+CCWA Set default value (<n>=0):

OK

Defined values

<n> Sets/shows the result code presentation status in the TA

0 – disable 1 – enable

<mode> When <mode> parameter is not given, network is not interrogated:

0 – disable 1 – enable 2 – query status

<class> It is a sum of integers each representing a class of information (default 7)

1 – voice (telephony) 2 – data (refers to all bearer services) 4 – fax (facsimile services) 7 – voice,data and fax(1+2+4) 8 – short message service 16 – data circuit sync 32 – data circuit async 64 – dedicated packet access 128 – dedicated PAD access

<status> 0 – not active 1 – active

<number> String type phone number of calling address in format specified by <type>. <type> Type of address octet in integer format;

128 – Restricted number type includes unknown type and format 145 – International number type

129 – Otherwise

Examples

Page 118: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 117

AT+CCWA=? +CCWA:(0-1) OK AT+CCWA? +CCWA: 0 OK

6.11 AT+CHLD Call related supplementary services

Description The command allows the control of the following call related services:

1. A call can be temporarily disconnected from the ME but the connection is retained by the network.

2. Multiparty conversation (conference calls). 3. The served subscriber who has two calls (one held and the other either active or alerting)

can connect the other parties and release the served subscriber's own connection. Calls can be put on hold, recovered, released, added to conversation, and transferred.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CHLD=? +CHLD: (list of supported <n>s)

OK

Write Command Responses OK

ERROR

AT+CHLD=<n>

+CME ERROR: <err>

Execution Command Responses OK

ERROR

AT+CHLD Default to <n>=2.

+CME ERROR: <err>

Defined values

<n> 0 – Terminate all held calls; or set User Determined User Busy for a waiting call 1 – Terminate all active calls and accept the other call (waiting call or held call) 1X – Terminate a specific call X 2 – Place all active calls on hold and accept the other call (waiting call or held call) as

Page 119: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 118

the active call 2X – Place all active calls except call X on hold 3 – Add the held call to the active calls 4 – Connect two calls and cut off the connection between users and them simultaneously

Examples

AT+CHLD=? +CHLD: (0,1,1x,2,2x,3,4) OK

6.12 AT+CUSD Unstructured supplementary service data

Description The command allows control of the Unstructured Supplementary Service Data (USSD). Both network and mobile initiated operations are supported. Parameter <n> is used to disable/enable the presentation of an unsolicited result code (USSD response from the network, or network initiated operation) +CUSD: <m>[,<str>,<dcs>] to the TE. In addition, value <n>=2 is used to cancel an ongoing USSD session.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CUSD=? +CUSD: (list of supported <n>s)

OK

Read Command Responses AT+CUSD? +CUSD: <n>

OK

Write Command Responses OK

ERROR

AT+CUSD= <n>[,<str>[,<dcs>]]

+CME ERROR: <err>

Execution Command Responses AT+CUSD Set default value (<n>=0):

OK

Defined values

<n>

Page 120: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 119

0 – disable the result code presentation in the TA 1 – enable the result code presentation in the TA 2 – cancel session (not applicable to read command response)

<str> String type USSD-string. <dcs> Cell Broadcast Data Coding Scheme in integer format (default 0). <m>

0 – no further user action required (network initiated USSD-Notify, or no further information needed after mobile initiated operation)

1 – further user action required (network initiated USSD-Request, or further information needed after mobile initiated operation)

2 – USSD terminated by network 4 – operation not supported 5 – network time out

Examples

AT+CUSD? +CUSD: 1 OK AT+CUSD=0 OK

6.13 AT+CAOC Advice of charge

Description The refers to Advice of Charge supplementary service that enables subscriber to get information about the cost of calls. With <mode>=0, the execute command returns the current call meter value from the ME. The command also includes the possibility to enable an unsolicited event reporting of the CCM information. The unsolicited result code +CCCM: <ccm> is sent when the CCM value changes, but not more that every 10 seconds. Deactivation of the unsolicited event reporting is made with the same command.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CAOC=? +CAOC: (list of supported <mode>s)

OK

Page 121: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 120

Read Command Responses +CAOC: <mode> OK

ERROR

AT+CAOC?

+CME ERROR: <err>

Write Command Responses +CAOC: <ccm> OK

ERROR

AT+CAOC=<mode>

+CME ERROR: <err>

Execution Command Responses AT+ CAOC Set default value (<mode>=1):

OK

Defined values

<mode> 0 – query CCM value 1 – deactivate the unsolicited reporting of CCM value 2 – activate the unsolicited reporting of CCM value

<ccm> String type, three bytes of the current call meter value in hexadecimal format (e.g. "00001E" indicates decimal value 30), value is in home units and bytes are similarly coded as ACMmax value in the SIM.

Examples

AT+CAOC=0 +CAOC: "000000" OK

6.14 AT+CSSN Supplementary service notifications

Description

Page 122: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 121

The command refers to supplementary service related network initiated notifications. The set command enables/disables the presentation of notification result codes from TA to TE. When <n>=1 and a supplementary service notification is received after a mobile originated call setup, intermediate result code +CSSI: <code1>[,<index>] is sent to TE before any other MO call setup result codes presented in the present document. When several different <code1>s are received from the network, each of them shall have its own +CSSI result code. When <m>=1 and a supplementary service notification is received during a mobile terminated call setup or during a call, or when a forward check supplementary service notification is received, unsolicited result code +CSSU: <code2>[,<index>[,<number>,<type>[,<subaddr>,<satype>]]] is sent to TE. In case of MT call setup, result code is sent after every +CLIP result code (refer command "Calling line identification presentation +CLIP") and when several different <code2>s are received from the network, each of them shall have its own +CSSU result code.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CSSN=? +CSSN: (list of supported <n>s),(list of supported <m>s)

OK

Read Command Responses AT+CSSN? +CSSN: <n>,<m>

OK

Write Command Responses OK

ERROR

AT+CSSN=<n>[,<m>]

+CME ERROR: <err>

Defined values

<n> Parameter sets/shows the +CSSI result code presentation status in the TA:

0 – disable 1 – enable

<m> Parameter sets/shows the +CSSU result code presentation status in the TA:

0 – disable 1 – enable

<code1> 0 – unconditional call forwarding is active 1 – some of the conditional call forwarding are active 2 – call has been forwarded

Page 123: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 122

3 – call is waiting 5 – outgoing calls are barred

<index> Refer "Closed user group +CCUG". <code2>

0 – this is a forwarded call (MT call setup) 2 – call has been put on hold (during a voice call) 3 – call has been retrieved (during a voice call) 5 – call on hold has been released (this is not a SS notification) (during a voice call)

<number> String type phone number of format specified by <type>. <type> Type of address octet in integer format; default 145 when dialing string includes international access code character "+", otherwise 129. <subaddr> String type sub address of format specified by <satype>. <satype> Type of sub address octet in integer format, default 128.

Examples

AT+CSSN=1,1 OK AT+CSSN? +CSSN: 1,1 OK

6.15 AT+CLCC List current calls

Description Return list of current calls of ME. If command succeeds but no calls are available, no information response is sent to TE.

SIM PIN References

NO 3GPP TS 27.007

Syntax

Test Command Responses AT+CLCC=? +CLCC: (list of supported <n>s)

OK

Read Command Responses

Page 124: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 123

AT+CLCC? +CLCC: <n> OK

Write Command Responses AT+CLCC=<n> OK

Execution Command Responses +CLCC:<id1>,<dir>,<stat>,<mode>,<mpty>[,<number>,<type>[,<alpha>]][<CR><LF> +CLCC:<id2>,<dir>,<stat>,<mode>,<mpty>[,<number>,<type>[,<alpha>]] [...]] OK

ERROR

AT+CLCC

+CME ERROR: <err>

Defined values

<n> 0 – Don’t report a list of current calls of ME automatically when the current call status

changes. 1 – Report a list of current calls of ME automatically when the current call status changes.

<idX> Integer type, call identification number, this number can be used in +CHLD command operations. <dir>

0 – mobile originated (MO) call 1 – mobile terminated (MT) call

<stat> State of the cal:

0 – active 1 – held 2 – dialing (MO call) 3 – alerting (MO call) 4 – incoming (MT call) 5 – waiting (MT call) 6 – disconnect

<mode> bearer/teleservice:

0 – voice 1 – data 2 – fax 9 – unknown

<mpty> 0 – call is not one of multiparty (conference) call parties

Page 125: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 124

1 – call is one of multiparty (conference) call parties <number> String type phone number in format specified by <type>. <type> Type of address octet in integer format;

128 – Restricted number type includes unknown type and format 145 – International number type 161 – national number.The network support for this type is optional 177 – network specific number,ISDN format

129 – Otherwise <alpha> String type alphanumeric representation of <number> corresponding to the entry found in phonebook; used character set should be the one selected with command Select TE Character Set AT+CSCS.

Examples

ATD10011; OK AT+CLCC +CLCC: 1,0,0,0,0,"10011",129,"sm" OK RING (with incoming call) AT+CLCC +CLCC: 1,1,4,0,0,"02152063113",128,"gongsi" OK

6.16 AT+CPOL Preferred operator list

Description The command is used to edit the SIM preferred list of networks.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CPOL=? +CPOL: (list of supported <index>s), (list of supported <format>s)

OK

Read Command Responses

Page 126: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 125

AT+CPOL? [+CPOL:<index1>,<format>,<oper1>[<GSM_AcT1>,<GSM_Compact_AcT1>,<UTRAN_AcT1> ][<CR><LF> +CPOL: <index2>,<format>,<oper2>[,<GSM_AcT1>,<GSM_Compact_AcT1>,<UTRAN_AcT1> ] [...]]] OK

Write Command Responses OK

ERROR

AT+CPOL=<index> [,<format>[,<oper>][,<GSM_AcT1>,<GSM_Compact_AcT1>,<UTRAN_AcT1> ]] NOTE: If using USIM card, the last three parameters must set.

+CME ERROR: <err>

Defined values

<index> Integer type, the order number of operator in the SIM preferred operator list. If only input <index>, command will delete the value indicate by <index>. <format>

0 – long format alphanumeric <oper> 1 – short format alphanumeric <oper> 2 – numeric <oper>

<operX> String type. <GSM_AcTn>

GSM access technology: 0 – access technology not selected 1 – access technology selected

<GSM_Compact_AcTn> GSM compact access technology: 0 – access technology not selected 1 – access technology selected

<UTRA_AcTn> UTRA access technology: 0 – access technology not selected 1 – access technology selected

Examples

AT+CPOL?

Page 127: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 126

+CPOL: 1,2,"46001",0,0,1 OK AT+CPOL=? +CPOL: (1-8),(0-2) OK

6.17 AT+COPN Read operator names

Description Execute command returns the list of operator names from the ME. Each operator code <numericX> that has an alphanumeric equivalent <alphaX> in the ME memory shall be returned.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+COPN=? OK

Write Command Responses +COPN:<numeric1>,<alpha1>[<CR><LF> +COPN: <numeric2>,<alpha2> [...]] OK

ERROR

AT+COPN

+CME ERROR: <err>

Defined values

<numericX> String type, operator in numeric format (see AT+COPS). <alphaX> String type, operator in long alphanumeric format (see AT+COPS).

Examples

AT+COPN +COPN: "46000","China Mobile Com" +COPN: "46001"," China Unicom" …… OK

Page 128: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 127

6.18 AT+CNMP Preferred mode selection

Description The command is used to select or set the state of the mode preference.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CNMP=? +CNMP: (list of supported <mode>s)

OK

Read Command Responses AT+CNMP? +CNMP: <mode>

OK

Write Command Responses OK AT+CNMP=<mode>

ERROR

Defined values

<mode> 2 – Automatic 13 – GSM Only 14 – WCDMA Only

Examples

AT+CNMP=13 OK AT+CNMP? +CNMP: 2 OK

6.19 AT+CNBP Preferred band selection

Description The command is used to select or set the state of the band preference.

SIM PIN References

Page 129: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 128

YES Vendor

Syntax

Test Command Responses AT+CNBP? +CNBP: <mode>

OK

Write Command Responses OK AT+CNBP=<mode>

ERROR

Defined values

<mode> 64bit number, the value is “1” << “<pos>” , then or by bit. <pos> Value:

0xFFFFFFFF7FFFFFFF Any (any value) 7 GSM_DCS_1800 8 GSM_EGSM_900 9 GSM_PGSM_900 16 GSM_450 17 GSM_480 18 GSM_750 19 GSM_850 20 GSM_RGSM_900 21 GSM_PCS_1900 22 WCDMA_IMT_2000 23 WCDMA_PCS_1900 24 WCDMA_III_1700 25 WCDMA_IV_1700 26 WCDMA_850 27 WCDMA_800 48 WCDMA_VII_2600 49 WCDMA_VIII_900 50 WCDMA_IX_1700

Examples

AT+CNBP=0x000700000FFF0380 OK AT+CNBP? +CNBP: 0xFFFFFFFF3FFFFFFF

Page 130: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 129

OK

6.20 AT+CNAOP Acquisitions order preference

Description Write command resets the state of acquisitions order preference.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CNAOP=? +CNAOP: (list of supported <mode>s)

OK

Read Command Responses AT+CNAOP? +CNAOP: <mode>

OK

Write Command Responses OK AT+CNAOP=<mode>

ERROR

Defined values

<mode> 0 – Automatic 1 – GSM,WCDMA 2 – WCDMA,GSM

Examples

AT+CNAOP=1 OK AT+CNAOP? +CNAOP: 2 OK

6.21 AT+CNSDP Preferred service domain selection

Description Write command resets the state of the service domain preference.

Page 131: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 130

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CNSDP=? +CNSDP: (list of supported <mode>s)

OK

Read Command Responses AT+CNSDP? +CNSDP: <mode>

OK

Write Command Responses OK AT+CNSDP=<mode>

ERROR

Defined values

<mode> 0 – CS Only 1 – PS Only 2 – CS + PS

Examples

AT+CNSDP=2 OK AT+CNSDP? +CNSDP: 0 OK

6.22 AT+CPSI Inquiring UE system information

Description The command returns the UE system information.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CPSI=? +CPSI: (scope of <time>)

Page 132: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 131

OK

Read Command Responses If camping on a 2G cell: +CPSI:<System Mode>,<Operation Mode>,<MCC>- <MNC> <LAC>,<Cell ID>,<Absolute RF Ch Num>, < RxLev >, <Track LO Adjust>,<C1-C2> OK

If camping on a 3G cell: +CPSI: <System Mode>, <Operation Mode>, <MCC>- <MNC>,<LAC>,<Cell ID>,<Frequency Band>, <PSC>, <Freq>, <SSC>,<EC/IO>,< RSCP >,<Qual>,<RxLev>,<TXPWR> OK

AT+CPSI?

ERROR

Write Command Responses OK AT+CPSI=<time>

ERROR

Defined values

<time> The range is 0-255, unit is second, after set <time> will report the system information every the seconds. <System Mode> System mode, values: “NO SERVICE”, “GSM” or “WCDMA”. <Operation Mode> UE operation mode, values: “Online”,“Offline”,“Factory Test Mode”,“Reset”, “Low Power Mode”.<MCC> Mobile Country Code (first part of the PLMN code) <MNC> Mobile Network Code (second part of the PLMN code) <LAC> Location Area Code (hexadecimal digits) <Cell ID> Service-cell ID. <Absolute RF Ch Num> AFRCN for service-cell. <Track LO Adjust> Track LO Adjust <C1> Coefficient for base station selection <C2> Coefficient for Cell re-selection

Page 133: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 132

<Frequency Band> Frequency Band of active set <PSC> Primary synchronization code of active set. <Freq> Downlink frequency of active set. <SSC> Secondary synchronization code of active set <EC/IO> Ec/Io value <RSCP> Received Signal Code Power <Qual> Quality value for base station selection <RxLev> RX level value for base station selection <TXPWR> UE TX power in dBm. If no TX, the value is 500.

Examples

AT+CPSI? +CPSI: GSM,Online,460-00 0x182d,12401,27 EGSM 900,-64,2110,42-42 OK AT+CPSI=? +CPSI: WCDMA,Online,001-01,0xED2E ,WCDMA IMT 2000,0,9,10688,0,6,62,43,45,500 OK AT+CPSI=? +CPSI: (0-255) OK

6.23 AT+CNSMOD Show network system mode

Description The command returns the current network system mode.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CNSMOD=? +CNSMOD: (list of supported <n>s)

Page 134: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 133

OK

Read Command Responses +CNSMOD: <n>,<stat> OK

ERROR

AT+CNSMOD?

+CME ERROR: <err>

Write Command Responses OK

ERROR

AT+CNSMOD=<n>

+CME ERROR: <err>

Defined values

<n> 0 – disable auto report the network system mode information 1 – auto report the network system mode information, command: +CNSMOD:<stat>

<state> 0 – no service 1 – GSM 2 – GPRS 3 – EGPRS (EDGE) 4 – WCDMA 5 – HSDPA only 6 – HSUPA only 7 – HSPA (HSDPA and HSUPA)

Examples

AT+CNSMOD? +CNSMOD: 0,2 OK

6.24 AT+CTZU Automatic time and time zone update

Description The command is used to enable and disable automatic time and time zone update via NITZ.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Page 135: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 134

Test Command Responses AT+CTZU=? +CTZU: (list of supported <onoff>s)

OK

Read Command Responses AT+CTZU? +CTZU: <onoff>

OK

Write Command Responses OK AT+CTZU=<onoff>

ERROR

Defined values

<onoff> Integer type value indicating: 0 – Disable automatic time zone update via NITZ (default).

1 – Enable automatic time zone update via NITZ. NOTE 1. The value of <onoff> is nonvolatile, and factory value is 0.

2. For automatic time and time zone update is enabled (+CTZU=1): If time zone is only received from network and it doesn’t equal to local time zone (AT+CCLK), time zone is updated automatically, and real time clock is updated based on local time and the difference between time zone from network and local time zone (Local time zone must be valid). If Universal Time and time zone are received from network, both time zone and real time clock is updated automatically, and real time clock is based on Universal Time and time zone from network.

Examples

AT+CTZU? +CTZU: 0 OK AT+CTZU=1 OK

6.25 AT+CTZR Time and time zone reporting

Description The command is used to enable and disable the time zone change event reporting. If the reporting is enabled the MT returns the unsolicited result code +CTZV: <tz>[,<time>][,<dst>]whenever the time zone is changed. NOTE The time zone reporting is not affected by the Automatic Time and Time Zone command

AT+CTZU.

Page 136: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 135

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CTZR=? +CTZR: (list of supported <onoff>s)

OK

Read Command Responses AT+CTZR? +CTZR: <onoff>

OK

Write Command Responses OK AT+CTZR=<onoff>

ERROR

Execution Command Responses AT+CTZR Set default value:

OK

Defined values

<onoff> Integer type value indicating: 0 – Disable time zone change event reporting (default).

1 – Enable time zone change event reporting. +CTZV: <tz>[,<time>][,<dst>] Unsolicited result code when time zone received from network doesn’t equal to local time zone, and if the informations from network don’t include date and time, time zone will be only reported, and if network daylight saving time is present, it is also reported. For example:

+CTZV: 32 (Only report time zone) +CTZV: 32,1 (Report time zone and network daylight saving time) +CTZV: 32,08/12/09,17:00:00 (Report time and time zone) +CTZV: 32,08/12/09,17:00:00,1 (Report time, time zone and daylight saving time)

For more detailed informations about time and time zone, please refer 3GPP TS 24.008. <tz> Local time zone received from network. <time> Universal time received from network, and the format is “yy/MM/dd,hh:mm:ss”,

where characters indicate year (two last digits), month, day, hour, minutes and seconds.

<dst> Network daylight saving time, and if it is received from network, it indicates the value that has been used to adjust the local time zone. The values as following:

0 – No adjustment for Daylight Saving Time. 1 – +1 hour adjustment for Daylight Saving Time. 2 – +2 hours adjustment for Daylight Saving Time.

Page 137: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 136

NOTE Herein, <time> is Universal Time or NITZ time, but not local time.

Examples

AT+CTZR? +CTZR: 0 OK AT+CTZR=1 OK

6.26 AT+CCINFO Show cell system information

Description The command is used to inquire serving cell and neighbors cell system information in GSM.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CCINFO=? OK

Execution Command Responses AT+CCINFO When ME in idle mode:

+CCINFO:[<SCELL>],ARFCN:<arfcn>,MCC:<mcc>,MNC:<mnc>,LAC:<lac>,ID:<id>,BSIC:<bsic>,RXLev:<rxlev>,C1:<c1>,C2:<c2>,TA:<TA>,TXPWR:<TXPWR> +CCINFO:[<NCELLn>],ARFCN:<arfcn>,MCC:<mcc>,MNC:<mnc>,LAC:<lac>,ID:<id>,BSIC:<bsic>,RXLev:<rxlev>,C1:<c1>,C2:<c2> […] When ME in dedicated mode: +CCINFO:[<SCELL>],ARFCN:<arfcn>,MCC:<mcc>,MNC:<mnc>,LAC:<lac>,ID:<id>,BSIC:<bsic>,RXLev:<rxlev>,C1:<c1>,C2:<c2>,TA:<TA>,TXPWR:<TXPWR> +CCINFO:[<NCELLn>],ARFCN:<arfcn>,BSIC:<bsic>,RXLev:<rxlev> […]

Defined values

<SCELL> indicate serving cell

Page 138: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 137

<NCELLn> available neighbour cell index <arfcn> assigned radio channel <mcc> mobile country code <mnc> mobile network code <lac> localization area code <id> cell identifier <bsic> base station identification code <rxlev> received signal strength in dBm <TA> timing advance <c1> Coefficient for base station selection <c2> Coefficient for Cell re-selection <TXPWR> UE TX power in dBm. If no TX, the value is 0.

Examples

AT+CCINFO (idle mode) +CCINFO:[SCELL],ARFCN:11,MCC:460,MNC:00,LAC:6360,ID:12402,BSIC:52,RXLev:-68dbm,C1:35,C2:35,TA:0,TXPWR:0 +CCINFO:[NCell1],ARFCN:29,MCC:460,MNC:00,LAC:6360,ID:12625,BSIC:55,RXLev:-81dbm,C1:21,C2:21 +CCINFO:[NCell2],ARFCN:28,MCC:460,MNC:00,LAC:6360,ID:8466,BSIC:49,RXLev:-81dbm,C1:21,C2:21 +CCINFO:[NCell3],ARFCN:25,MCC:460,MNC:00,LAC:6360,ID:8498,BSIC:40,RXLev:-81dbm,C1:21,C2:21 +CCINFO:[NCell4],ARFCN:2,MCC:460,MNC:00,LAC:6362,ID:24644,BSIC:48,RXLev:-87dbm,C1:15,C2:15 +CCINFO:[NCell5],ARFCN:14,MCC:460,MNC:00,LAC:6360,ID:12403,BSIC:54,RXLev:-86dbm,C1:16,C2:16 +CCINFO:[NCell6],ARFCN:13,MCC:460,MNC:00,LAC:6362,ID:24705,BSIC:51,RXLev:-89dbm,C1:13,C2:13 OK

Page 139: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 138

AT+CCINFO (dedicated mode) +CCINFO:[SCELL],ARFCN:11,MCC:460,MNC:00,LAC:6360,ID:12402,BSIC:52,RXLev:-61dbm,C1:42,C2:42,TXPWR:29 +CCINFO:[NCell1],ARFCN:25,BSIC:40,RXLev:-81dbm +CCINFO:[NCell2],ARFCN:28,BSIC:49,RXLev:-82dbm +CCINFO:[NCell3],ARFCN:29,BSIC:55,RXLev:-82dbm +CCINFO:[NCell4],ARFCN:14,BSIC:54,RXLev:-87dbm +CCINFO:[NCell5],ARFCN:2,BSIC:48,RXLev:-89dbm +CCINFO:[NCell6],ARFCN:13,BSIC:51,RXLev:-89dbm OK

6.27 AT+CSCHN Show cell channel information

Description The command is used to inquire serving cell channel information in GSM.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CSCHN=? OK

Execution Command Responses AT+CSCHN When during a call:

+CSCHN:ARFCN:<arfcn>,BISC:<bsic>,HSN:<hsn>,MAIO:<maio>, TN:<tn>,HF:<hf>,TSC:<tsc>,TCH:<tch> OK

Defined values

<arfcn> assigned radio channel <bsic> base station identification code <hsn> HSN <maio> MAIO <tn> timeslot number <hf>

Page 140: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 139

hopping flag <tsc> TSC <tch> channel type

Examples

AT+CSCHN +CSCHN: ARFCN:11, BISC: 52, HSN: 41, MAIO: 6, TN: 1, HF: 1, TSC: 4, TCH: 3 OK

6.28 AT+CSRP Show serving cell radio parameter

Description The command is used to inquire serving cell radio parameter in GSM.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CSRP=? OK

Execution Command Responses AT+CSRP When during a call:

+CSRP:ARFCN:<arfcn>,RXLevFull:<rxlevfull>,RXLevSub: <rxlevsub>,RXQualFull:<rxqualfull>,RXQualSub:<rxqualsub>, PWRC:<pwrc>,DTX:<dtx>,RLT:<rlt> OK

Defined values

<arfcn> assigned radio channel <rxlevfull> received full signal strength in dBm <rxlevsub> received sub signal strength in dBm <rxqualfull> full quality of reception <rxqualsub>

Page 141: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 140

sub quality of reception <pwrc> PWRC <dtx> DTX <rlt> radio link timeout

Examples

AT+CSRP +CSRP:ARFCN:11,RXLevFull:-88dbm,RXLevSub:-89dbm,RXQualFull:7,RXQualSub:7,PWRC:1,DTX:0,RLT:32 OK

6.29 AT+CRUS Show cell set system information

Description The execution command returns the mobile phone system information in WCDMA.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CRUS=? OK

Execution Command Responses AT+CRUS +CRUS: Active SET, <ActiveSET Cells Num>[, <ActiveSET

Cell1 PSC>, <ActiveSET Cell1 Freq>, <ActiveSET Cell1 SSC> , <ActiveSET Cell1 Sttd> , <ActiveSET Cell1 TotEcio> , <ActiveSET Cell1 Ecio> , <ActiveSET Cell1 Rscp> , <UTMS_SETS Cell TPC>, <UTMS_SETS Cell SecCpichOvsf>, <ActiveSET Cell1 WinSize> […]] +CRUS: Sync Neighbor SET, <SyncSET Cells Num>[, <SyncSET Cell1 PSC>, <SyncSET Cell1 Freq>, < SyncSET Cell1 SSC> , < SyncSET Cell1 Sttd> , < SyncSET Cell1 TotEcio> , < SyncSET Cell1 Ecio> , < SyncSET Cell1 Rscp> , < SyncSET Cell1 WinSize> […]] +CRUS: Async Neighbor SET, <AsyncSET Cells Num>[, < AsyncSET Cell1 PSC>, < AsyncSET Cell1 Freq>, < AsyncSET Cell1 SSC> , < AsyncSET Cell1 Sttd> , < AsyncSET Cell1

Page 142: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 141

TotEcio> , < AsyncSET Cell1 Ecio> , < AsyncSET Cell1 Rscp> , < AsyncSET Cell1 WinSize> […]] OK

Defined values

<UTMS_SETS Cells Num> cells number <UTMS_SETS Cell 1-n PSC> primary synchronization code of the cell <UTMS_SETS Cell 1-n Freq> downlink frequency of the cell <UTMS_SETS Cell 1-n SSC> secondary synchronization code <UTMS_SETS Cell 1-n Sttd> if the CPICH of this cell uses STTD <UTMS_SETS Cell 1-n TotEcio> the total Ec/Io in the best paths found in a sweep <UTMS_SETS Cell 1-n 1 Ecio> Ec/Io <UTMS_SETS Cell 1-n Rscp> CPICH RSCP <UTMS_SETS Cell 1-n TPC> Forward power control combination <UTMS_SETS Cell 1-n SecCpichOvsf> OVSF code of the secondary CPICH <UTMS_SETS Cell 1-n WinSize> search window size for this cell UTMS_SETS contains:

ActiveSET active set SyncSET neighbor (monitored) set for neighbors whose timing is known AsyncSET neighbor (monitored) set for neighbors whose timing is unknown

Examples

AT+CRUS +CRUS: Active SET,1,2,10663,0,0,16,16,101,0,0,1536 +CRUS: Sync Neighbor SET,2,42,10663,0,0,34,33,109,1536,35,10663,0,0,26,26,106,1536 +CRUS: Async Neighbor SET,10,11,10663,0,0,0,49,121,0,6,10663,0,0,0,49,121,0,28, 10663, 0, 0,0, 49,121,0,247,10663,0,0,0,49,121,0,193,10663,0,0,0,49,121,0,493,10663,0,0,0,49,121,0,485,10663,0,0,0,49,121,0,258,10663,0,0,0,49,121,0,109,10663,0,0,0,49,121,0,226,10663,0,0,38,49,121,1536 OK

Page 143: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 142

6.30 AT+CPLMNWLIST Manages PLMNs allowed by customer

Description The command is used to manage the PLMN list allowed by customer. After setting the plmnwlist, the module needs to be restart.

Syntax

Read Command Responses AT+CPLMNWLIST? +CPLMNWLIST: <plmnwlist>,<type>

OK

Write Command Responses OK AT+CPLMNWLIST=<plmn

wlist>[,<type>] ERROR

Defined values

<plmnwlist> The list of PLMN separated by semicolon. The maximum count of the items in the list is 20.

Empty list represents no filter. If the CPASSMGR has set password for this command, the password must be verified before operating this command. <type> The type of PLMN filter:

1 – filter by HPLMN. 2 – filter by PLMN of the wireless network. 3 – filter by both HPLMN and PLMN of the wireless network.

Examples

AT+CPLMNWLIST= “46000;46001” OK AT+CPLMNWLIST=”” OK AT+CPLMNWLIST? +CPLMNWLIST: “46000;46001”, 1 OK

6.31 AT+CPASSMGR Manage password

Description

Page 144: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 143

The command is used to manage password for some AT commands.

Syntax

Write Command Responses OK AT+CPASSMGR=<module

>, "<password>"[, <new_password>]

ERROR

Defined values

<module> The module for the password operation:

"cplmnwlist" – AT+CPLMNWLIST command <password> The password for the module. The maximum length is 8. <new_password> The new password for the module. The maximum length is 8.

Examples

AT+CPASSMGR=”cplmnwlist”, “”, “12345678” OK AT+CPASSMGR=”cplmnwlist”, “12345678”, “111111” OK AT+CPASSMGR=”cplmnwlist”,”111111” OK AT+CPASSMGR=”cplmnwlist”,”111111”,”” OK

6.32 AT+CNSVSQ Network band scan quickly

Description The command is used to perform a quick survey through channels belonging to the band selected, starting from channel <s> to channel <e>. If parameters are omitted, a full band scan is performed. After issuing the command, the information for every received BCCH(BCCH-Carrier and non BCCH-Carrier) is given in the format of string. SIM PIN References

NO Vendor

Syntax

Page 145: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 144

Write Command Responses Network survey started... For BCCH-Carrier: [arfcn: <arfcn_value>,bsic: <bsic_value>,dBm: <dBm_value>] […] For non BCCH-Carrier: [arfch: <arfcn_value>,dBm: <dBm_value>] […] Network survey end OK

AT+CNSVSQ=<s>,<e>

ERROR Execution Command Responses AT+CNSVSQ Network survey started...

For BCCH-Carrier: [arfcn: <arfcn_value>,bsic: <bsic_value>,dBm: <dBm_value>] […] For non BCCH-Carrier: [arfch: <arfcn_value>,dBm: <dBm_value>] […] Network survey end OK

Defined values

<s> starting channel. <e> ending channel. <arfcn_value> carrier assigned radio channel (BCCH – Broadcast Control Channel). <bsic_value> base station identification code. <dBm_value> the value of dBm.

Examples

AT+CNSVSQ Network survey started… For BCCH-Carrier: arfcn: 16,bsic: 45,dBm: -75 …… For non BCCH-Carrier:

Page 146: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 145

arfcn: 89,dBm: -82 arfcn: 1011,dBm: -86 …… Network survey end OK

6.33 AT+CNSVS Network full band scan in string format

Description The command is used to perform a quick survey through channels belonging to the band selected , starting from channel <s> to channel <e>. If parameters are omitted, a full band scan is performed. After issuing the command, the information for every received BCCH(BCCH-Carrier and non BCCH-Carrier) is given in the format of string. SIM PIN References

NO Vendor

Syntax

Read Command Responses AT+CNSVS? +CNSVS: <count>

OK Write Command Responses AT+CNSVS=<s>,<e> Network survey started…

For BCCH-Carrier: [arfcn: <arfcn_value>,bsic: <bsic_value>,dBm: <dBm_value>, <[mcc: <mcc_value>,mnc: <mnc_value>,lac: <lac_value>,cellId: <cellId>,cellStatus: <cellStasus>] or [SIB3 not available]>, <[numArfcn: <num_afrcn>, arfcn: <list of arfcns>] or [cell allocation empty]>,<[numChannels: <num_channel>,array: <list of channels>] or [SIB2 not available]>] […] For non BCCH-Carrier: [arfch: <arfcn_value>,dBm: <dBm_value>] […] Network survey end OK

AT+CNSVS=<arfcn_index> If BCCH-Carrier: arfcn: <arfcn_value>,bsic: <bsic_value>,dBm: <dBm_value>, <[mcc: <mcc_value>,mnc: <mnc_value>,lac: <lac_value>,cellId: <cellId>,cellStatus: <cellStasus>] or [SIB3 not available]>, <[numArfcn: <num_afrcn>, arfcn: <list of arfcns>] or [cell

Page 147: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 146

allocation empty]>,<[numChannels: <num_channel>,array: <list of channels>] or [SIB2 not available]> OK If non BCCH-Carrier: arfch: <arfcn_value>,dBm: <dBm_value> OK

+CNSVS: NOT IN GSM OK

+CNSVS: arfcn index invalid OK

ERROR Execution Command Responses AT+CNSVS Network survey started…

For BCCH-Carrier: [arfcn: <arfcn_value>,bsic: <bsic_value>,dBm: <dBm_value>, <[mcc: <mcc_value>,mnc: <mnc_value>,lac: <lac_value>,cellId: <cellId>,cellStatus: <cellStasus>] or [SIB3 not available]>, <[numArfcn: <num_afrcn>, arfcn: <list of arfcns>] or [cell allocation empty]>,<[numChannels: <num_channel>,array: <list of channels>] or [SIB2 not available]>] […] For non BCCH-Carrier: [arfch: <arfcn_value>,dBm: <dBm_value>] […] Network survey end OK

Defined values

<count> the count of arfcn. <s> starting channel. <e> ending channel. <arfcn_value> carrier assigned radio channel (BCCH – Broadcast Control Channel). <bsic_value> base station identification code. <dBm_value> the value of dBm. <mcc_value>

Page 148: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 147

mobile country code. <mnc_value> mobile network code. <lac_value> localization area code. <cellId> cell identifier. <cellStatus> cell status, this parameter indicates the following statuses: - CELL_SUITABLE indicates the C0 is a suitable cell. - CELL_LOW_PRIORITY indicates the cell is low priority based on the system information received. - CELL_FORBIDDEN indicates the cell is forbidden. - CELL_BARRED indicates the cell is barred based on the system information received. - CELL_LOW_LEVEL indicates the cell RXLEV is low. - CELL_OTHER indicates none of the above, e.g. exelusion timer running, no BCCH available etc. <num_arfcn> number of valid channels. <list of arfcns> list arfcns BCCH allocation, and the total number is <num_arfcn>. <num_channel> number of valid channels. <list of channels> list channels, and the total number is <num_channels>. <arfcn_index> the index of arfcn, and the minimum value is zero.

Examples

AT+CNSVS Network survey started... For BCCH-Carrier: arfcn: 600,bsic: 54,dBm: -98,mcc: 460,mnc: 0,lac: 6180,cellId: 49443,cellStatus: CELL_LOW_LEVEL, numArfcn: 6,arfcn: 518 521 542 547 574 600,numChannels: 25,array: 6 9 11 12 14 19 20 21 22 23 24 25 27 28 36 516 525 528 552 556 564 568 572 584 600 …… For non BCCH-Carrier: arfcn: 694,dBm: -94 …… Network survey end OK

Page 149: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 148

6.34 AT+CNSVN Network full band scan in numeric format

Description The command is used to perform a quick survey through channels belonging to the band selected, starting from channel <s> to channel <e>. If parameters are omitted, a full band scan is performed. After issuing the command, the information for every received BCCH(BCCH-Carrier and non BCCH-Carrier) is given in the format of string. SIM PIN References

NO Vendor

Syntax

Write Command Responses AT+CNSVN=<s>,<e> Network survey started…

If BCCH-Carrier: [<arfcn_value>,<bsic_value>,<dBm_value>,<[<mcc_value>, <mnc_value>,<lac_value>,<cellId>,<cellStasus>] or [SIB3 not available]>, <[<num_afrcn>,<list of arfcns>] or [cell allocation empty]>,<[<num_channel>,<list of channels>] or [SIB2 not available]>] […] If non BCCH-Carrier: [<arfcn_value>,<dBm_value>] […] Network survey end OK

If BCCH-Carrier: <arfcn_value>,<bsic_value>,<dBm_value>,<[<mcc_value>, <mnc_value>,<lac_value>,<cellId>,<cellStasus>] or [SIB3 not available]>, <[<num_afrcn>,<list of arfcns>] or [cell allocation empty]>,<[<num_channel>,<list of channels>] or [SIB2 not available]> OK If non BCCH-Carrier: <arfcn_value>,<dBm_value> OK

+CNSVN: NOT IN GSM OK

+CNSVN: arfcn index invalid OK

AT+CNSVN=<arfcn_index>

ERROR

Page 150: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 149

Execution Command Responses AT+CNSVN Network survey started…

If BCCH-Carrier: [<arfcn_value>,<bsic_value>,<dBm_value>,<[<mcc_value>, <mnc_value>,<lac_value>,<cellId>,<cellStasus>] or [SIB3 not available]>, <[<num_afrcn>,<list of arfcns>] or [cell allocation empty]>,<[<num_channel>,<list of channels>] or [SIB2 not available]>] […] If non BCCH-Carrier: [<arfcn_value>,<dBm_value>] […] Network survey end OK

Defined values

<count> the count of arfcn. <s> starting channel. <e> ending channel. <arfcn_value> carrier assigned radio channel (BCCH – Broadcast Control Channel). <bsic_value> base station identification code. <dBm_value> the value of dBm. <mcc_value> mobile country code. <mnc_value> mobile network code. <lac_value> localization area code. <cellId> cell identifier. <cellStatus> cell status, this parameter indicates the following statuses: - CELL_SUITABLE indicates the C0 is a suitable cell. - CELL_LOW_PRIORITY indicates the cell is low priority based on the system information received. - CELL_FORBIDDEN indicates the cell is forbidden.

Page 151: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 150

- CELL_BARRED indicates the cell is barred based on the system information received. - CELL_LOW_LEVEL indicates the cell RXLEV is low. - CELL_OTHER indicates none of the above, e.g. exelusion timer running, no BCCH available etc. <num_arfcn> number of valid channels. <list of arfcns> list arfcns BCCH allocation, and the total number is <num_arfcn>. <num_channel> number of valid channels. <list of channels> list channels, and the total number is <num_channels>. <arfcn_index> the index of arfcn, and the minimum value is zero.

Examples

AT+CNSVN Network survey started… 16,45,-82,460,0,6180,42545,0,5, 16 45 49 71 81,11, 11 12 14 16 19 20 21 22 24 26 27 …… 694, -94 …… Network survey end OK

6.35 AT+CNSVUS Network band scan by channels in string

Description The command is used to perform a quick survey of user defined channels. It scans the given channels. The result format is in string format. SIM PIN References

NO Vendor

Syntax

Write Command Responses AT+CNSVUS=<ch1>,[<ch2>,[…[<ch10>]]]

Network survey started… For BCCH-Carrier: [arfcn: <arfcn_value>,bsic: <bsic_value>,dBm: <dBm_value>, <[mcc: <mcc_value>,mnc: <mnc_value>,lac: <lac_value>,cellId: <cellId>,cellStatus: <cellStasus>] or [SIB3 not available]>,

Page 152: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 151

<[numArfcn: <num_afrcn>, arfcn: <list of arfcns>] or [cell allocation empty]>,<[numChannels: <num_channel>,array: <list of channels>] or [SIB2 not available]>] […] For non BCCH-Carrier: [arfch: <arfcn_value>,dBm: <dBm_value>] […] Network survey end OK

+CNSVN: NOT IN GSM OK

ERROR

Defined values

<chN> channel number(arfcn). It must be in an increasing order, and the range of “N” is from 1 to 10. <arfcn_value> carrier assigned radio channel (BCCH – Broadcast Control Channel). <bsic_value> base station identification code. <dBm_value> the value of dBm. <mcc_value> mobile country code. <mnc_value> mobile network code. <lac_value> localization area code. <cellId> cell identifier. <cellStatus> cell status, this parameter indicates the following statuses: - CELL_SUITABLE indicates the C0 is a suitable cell. - CELL_LOW_PRIORITY indicates the cell is low priority based on the system information received. - CELL_FORBIDDEN indicates the cell is forbidden. - CELL_BARRED indicates the cell is barred based on the system information received. - CELL_LOW_LEVEL indicates the cell RXLEV is low. - CELL_OTHER indicates none of the above, e.g. exelusion timer running, no BCCH available etc. <num_arfcn> number of valid channels.

Page 153: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 152

<list of arfcns> list arfcns BCCH allocation, and the total number is <num_arfcn>. <num_channel> number of valid channels. <list of channels> list channels, and the total number is <num_channels>.

Examples

AT+CNSVUS=16,20,86,96,109 Network survey started... For BCCH-Carrier: arfcn: 16,bsic: 45,dBm: -80,mcc: 460,mnc: 0,lac: 6180,cellId: 42545,cellStatus:CELL_SUITABLE, numArfcn: 5,arfcn: 16 45 49 71 81,numChannels: 11,array: 11 12 14 16 19 20 21 22 24 26 27 For non BCCH-Carrier: arfcn: 86,dBm: -97 Network survey end OK

6.36 AT+CNSVUN Network band scan by channels in numeric

Description The command is used to performing a quick survey of user defined channels. It scans the given channels. The result is given in numeric format. SIM PIN References

NO Vendor

Syntax

Write Command Responses AT+CNSVUN=<ch1>,[<ch2>,[…[<ch10>]]]

Network survey started… For BCCH-Carrier: [<arfcn_value>,<bsic_value>,<dBm_value>,<[<mcc_value>, <mnc_value>,<lac_value>,<cellId>,<cellStasus>] or [SIB3 not available]>, <[<num_afrcn>,<list of arfcns>] or [cell allocation empty]>,<[<num_channel>,<list of channels>] or [SIB2 not available]>] […] For non BCCH-Carrier: [ <arfcn_value>, <dBm_value>] […] Network survey end

Page 154: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 153

OK

+CNSVN: NOT IN GSM OK

ERROR

Defined values

<chN> channel number(arfcn). It must be in a increasing order, and the range of “N” is from 1 to 10. <arfcn_value> carrier assigned radio channel (BCCH – Broadcast Control Channel). <bsic_value> base station identification code. <dBm_value> the value of dBm. <mcc_value> mobile country code. <mnc_value> mobile network code. <lac_value> localization area code. <cellId> cell identifier. <cellStatus> cell status, this parameter indicates the following statuses: - CELL_SUITABLE indicates the C0 is a suitable cell. - CELL_LOW_PRIORITY indicates the cell is low priority based on the system information received. - CELL_FORBIDDEN indicates the cell is forbidden. - CELL_BARRED indicates the cell is barred based on the system information received. - CELL_LOW_LEVEL indicates the cell RXLEV is low. - CELL_OTHER indicates none of the above, e.g. exelusion timer running, no BCCH available etc. <num_arfcn> number of valid channels. <list of arfcns> list arfcns BCCH allocation, and the total number is <num_arfcn>. <num_channel> number of valid channels. <list of channels> list channels, and the total number is <num_channels>.

Examples

Page 155: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 154

AT+CNSVUN=16,20,86,96,109 Network survey started... For BCCH-Carrier: 14,51, -89, 460, 0, 6180, 41074,0, 8, 5 7 14 51 61 65 74 88, 24, 2 3 9 11 12 15 16 17 19 20 22 24 25 26 27 28 36 81 516 520 525 532 556 600 For non BCCH-Carrier: 86, -97 Network survey end OK

6.37 AT+CCGMDF Enable single mode in RAT balancing mode

Description The command is used to enable or disable single mode in RAT balancing mode. This command is used for test purpose only. The default setting of RAT balancing depends on EF-RAT, and usually it is “Dual Mode”. After calling AT+CCGMDF=1 and AT+CNMP=13 or 14, the mode can be changed to single mode. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CCGMDF=? +CCGMDF: (0,1)

OK

Read Command Responses AT+CCGMDF? +CCGMDF: <mode>

OK

Write Command Responses OK AT+CCGMDF=<mode> ERROR

Defined values

<mode> Whether to enable or disable single mode in RAT balancing condition (mode depends on AT+CNMP):

0 – Disable. 1 – Enable.

Examples

Page 156: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 155

AT+CCGMDF=1 OK AT+CCGMDF? +CCGMDF:0 OK AT+CCGMDF=? +CCGMDF:(0-1) OK

6.38 AT+CPLMNPASS Manage PLMN filter password

Description The command is used to manage password for AT+CPLMNWLIST.

Syntax

Write Command Responses OK AT+CPLMNPASS="<passw

ord>"[, <new_password>] ERROR

Defined values

<password> The password for the module. The maximum length is 8. <new_password> The new password for the module. The maximum length is 8.

Examples

AT+CPLMNPASS= “”, “12345678” OK AT+CPLMNPASS= “12345678”, “111111” OK AT+CPLMNPASS=”111111” OK AT+CPLMNPASS=”111111”,”” OK

6.39 AT*CNTI Query Network Mode

Description

Page 157: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 156

The command is used to query the network mode of the module.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT*CNTI=? *CNTI: (list of supported <CNTI_option>s)

OK

Read Command Responses AT*CNTI? *CNTI:<CNTI_option>, <network_mode>

OK

Write Command Responses *CNTI:<CNTI_option>, <network_mode>s OK

AT*CNTI = <CNTI_option>

ERROR

Defined values

<CNTI_option> Network query option. Value:

0 Query the current network mode 1 Query the network mode available for the module now 2 Query the network mode supported by the module

<network_mode> The wireless access technologies separated by ‘,’. For some products, the HSDPA or HSUPA is not supported. Value:

NONE GSM GPRS EDGE UMTS HSDPA HSUPA

Examples

AT*CNTI =1

Page 158: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 157

*CNTI: 1, UMTS OK AT*CNTI? *CNTI: 1, GSM, GPRS OK

7 Mobile Equipment Control and Status Commands

7.1 +CME ERROR Mobile Equipment error result code

Description The operation of +CME ERROR:<err> result code is similar to the regular ERROR result code: if +CME ERROR: <err> is the result code for any of the commands in a command line, none of the following commands in the same command line is executed (neither ERROR nor OK result code shall be returned as a result of a completed command line execution). The format of <err> can be either numeric or verbose. This is set with command AT+CMEE.

SIM PIN References

NO 3GPP TS 27.007

Syntax

+CME ERROR: <err>

Defined values

<err> Values (numeric format followed by verbose format):

0 phone failure 1 no connection to phone 2 phone adaptor link reserved 3 operation not allowed 4 operation not supported 5 PH-SIM PIN required 6 PH-FSIM PIN required 7 PH-FSIM PUK required 10 SIM not inserted 11 SIM PIN required 12 SIM PUK required

Page 159: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 158

13 SIM failure 14 SIM busy 15 SIM wrong 16 incorrect password 17 SIM PIN2 required 18 SIM PUK2 required 20 memory full 21 invalid index 22 not found 23 memory failure 24 text string too long 25 invalid characters in text string 26 dial string too long 27 invalid characters in dial string 30 no network service 31 network timeout 32 network not allowed - emergency calls only 40 network personalization PIN required 41 network personalization PUK required 42 network subset personalization PIN required 43 network subset personalization PUK required 44 service provider personalization PIN required 45 service provider personalization PUK required 46 corporate personalization PIN required 47 corporate personalization PUK required 100 Unknown 103 Illegal MESSAGE 106 Illegal ME 107 GPRS services not allowed 111 PLMN not allowed 112 Location area not allowed 113 Roaming not allowed in this location area 132 service option not supported 133 requested service option not subscribed 134 service option temporarily out of order 148 unspecified GPRS error 149 PDP authentication failure 150 invalid mobile class 257 network rejected request 258 retry operation 259 invalid deflected to number 260 deflected to own number 261 unknown subscriber

Page 160: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 159

262 service not available 263 unknown class specified 264 unknown network message 273 minimum TFTS per PDP address violated 274 TFT precedence index not unique 275 invalid parameter combination

“CME ERROR” codes of MMS: 170 Unknown error for mms 171 MMS task is busy now 172 The mms data is over size 173 The operation is overtime 174 There is no mms receiver 175 The storage for address is full 176 Not find the address 177 Invalid parameter 178 Failed to read mss 179 There is not a mms push message 180 Memory error 181 Invalid file format 182 The mms storage is full 183 The box is empty 184 Failed to save mms 185 It’s busy editing mms now 186 It’s not allowed to edit now 187 No content in the buffer 188 Failed to receive mms 189 Invalid mms pdu 190 Network error 191 Failed to read file 192 None

“CME ERROR” codes of FTP: 201 Unknown error for FTP 202 FTP task is busy 203 Failed to resolve server address 204 FTP timeout 205 Failed to read file 206 Failed to write file 207 It’s not allowed in current state 208 Failed to login 209 Failed to logout 210 Failed to transfer data 211 FTP command rejected by server 212 Memory error

Page 161: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 160

213 Invalid parameter 214 Network error

“CME ERROR” codes of HTTP: 220 Unknown error fot HTTP 221 HTTP task is busy 222 Failed to resolve server address 223 HTTP timeout 224 Failed to transfer data 225 Memory error 226 Invalid parameter 227 Network error

Examples

AT+CPIN="1234","1234" +CME ERROR: incorrect password

7.2 AT+CMEE Report mobile equipment error

Description The command controls the format of the error result codes that indicates errors related to Sim5320

Functionality.Format can be selected between plain “ERROR” output,error numbers or verbose “+CME ERROR: <err>” and “+CMS ERROR: <err>” messages. SIM PIN References

NO 3GPP TS 27.007

Syntax

Test Command Responses AT+CMEE=? +CMEE: (list of supported <n>s)

OK

Read Command Responses AT+CMEE? +CMEE: <n>

OK

Write Command Responses OK AT+CMEE=<n>

ERROR

Execution Command Responses AT+CMEE Set default value:

OK

Page 162: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 161

Defined values

<n> 0 – Disable result code,i.e. only “ERROR” will be displayed. 1 – Enable error result code with numeric values. 2 – Enable error result code with string values.

Examples

AT+CMEE? +CMEE: 2 OK AT+CPIN="1234","1234" +CME ERROR: incorrect password AT+CMEE=0 OK AT+CPIN="1234","1234" ERROR AT+CMEE=1 OK AT+CPIN="1234","1234" +CME ERROR: 16

7.3 AT+CPAS Phone activity status

Description Execution command returns the activity status <pas> of the ME. It can be used to interrogate the ME before requesting action from the phone.

SIM PIN References

NO 3GPP TS 27.007

Syntax

Test Command Responses AT+CPAS=? +CPAS: (list of supported <pas>s)

OK

Execution Command Responses AT+CPAS +CPAS: <pas>

OK

Defined values

Page 163: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 162

<pas> 0 – ready (ME allows commands from TA/TE) 3 – ringing (ME is ready for commands from TA/TE, but the ringer is active) 4 – call in progress (ME is ready for commands from TA/TE, but a call is in progress)

Examples

RING (with incoming call) AT+CPAS +CPAS: 3 OK AT+CPAS=? +CPAS: (0,3,4) OK

7.4 AT+CFUN Set phone functionality

Description The command selects the level of functionality <fun> in the ME. Level "full functionality" is where the highest level of power is drawn. "Minimum functionality" is where minimum power is drawn. Level of functionality between these may also be specified by manufacturers. When supported by manufacturers, ME resetting with <rst> parameter may be utilized. NOTE AT+CFUN=6 must be used after setting AT+CFUN=7.

SIM PIN References

NO 3GPP TS 27.007

Syntax

Test Command Responses +CFUN: (list of supported <fun>s), (list of supported <rst>s) OK

ERROR

AT+CFUN=?

+CME ERROR: <err>

Read Command Responses +CFUN: <fun> OK

ERROR

AT+CFUN?

+CME ERROR: <err>

Write Command Responses OK AT+CFUN=<fun>[,<rst>]

ERROR

Page 164: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 163

+CME ERROR: <err>

Defined values

<fun> 0 – minimum functionality 1 – full functionality, online mode 4 – disable phone both transmit and receive RF circuits 5 – Factory Test Mode 6 – Reset 7 – Offline Mode

<rst> 0 – do not reset the ME before setting it to <fun> power level 1 – reset the ME before setting it to <fun> power level. This value only takes effect when

<fun> equals 1.

Examples

AT+CFUN? +CFUN: 1 OK AT+CFUN=0 OK

7.5 AT+CPIN Enter PIN

Description The command sends to the ME a password which is necessary before it can be operated (SIM PIN, SIM PUK, PH-SIM PIN, etc.). If the PIN is to be entered twice, the TA shall automatically repeat the PIN. If no PIN request is pending, no action is taken towards MT and an error message, +CME b is returned to TE. If the PIN required is SIM PUK or SIM PUK2, the second pin is required. This second pin, <newpin>, is used to replace the old pin in the SIM.

SIM PIN References

NO 3GPP TS 27.007

Syntax

Test Command Responses AT+CPIN=? OK

Read Command Responses AT+CPIN? +CPIN: <code>

Page 165: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 164

OK

ERROR

+CME ERROR: <err>

Write Command Responses OK

ERROR

AT+CPIN= <pin>[,<newpin>]

+CME ERROR: <err>

Defined values

<pin> String type values. <newpin> String type values. <code> Values reserved by the present document:

READY – ME is not pending for any password SIM PIN – ME is waiting SIM PIN to be given SIM PUK – ME is waiting SIM PUK to be given PH-SIM PIN – ME is waiting phone-to-SIM card password to be given SIM PIN2 – ME is waiting SIM PIN2 to be given SIM PUK2 – ME is waiting SIM PUK2 to be given PH-NET PIN – ME is waiting network personalization password to be given

Examples

AT+CPIN? +CPIN: SIM PUK2 OK

7.6 AT+CSQ Signal quality

Description Execution command returns received signal strength indication <rssi> and channel bit error rate <ber> from the ME. Test command returns values supported by the TA as compound values.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses

Page 166: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 165

AT+CSQ=? +CSQ: (list of supported <rssi>s),(list of supported <ber>s) OK

Execution Command Responses +CSQ: <rssi>,<ber> OK

AT+CSQ

ERROR

Defined values

<rssi> 0 – -113 dBm or less 1 – -111 dBm 2...30 – -109... -53 dBm 31 – -51 dBm or greater 99 – not known or not detectable

<ber> (in percent)

0 – <0.01% 1 – 0.01% --- 0.1% 2 – 0.1% --- 0.5% 3 – 0.5% --- 1.0% 4 – 1.0% --- 2.0% 5 – 2.0% --- 4.0% 6 – 4.0% --- 8.0% 7 – >=8.0% 99 – not known or not detectable

Examples

AT+CSQ +CSQ: 22,0 OK

7.7 AT+AUTOCSQ Set CSQ report

Description The command causes the module to disable and enable auto report CSQ information, if we enable auto report, the module reports CSQ information every five seconds or only after <rssi> or <ber> changing, the format of report is “+CSQ: <rssi>,<ber>”.

SIM PIN References

NO Vendor

Page 167: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 166

Syntax

Test Command Responses AT+AUTOCSQ=? +AUTOCSQ: (list of supported<auto>s),(list of supported<mod

e>s) OK

Read Command Responses AT+AUTOCSQ? +AUTOCSQ: <auto>,<mode>

OK

Write Command Responses OK AT+AUTOCSQ=<auto>[,<

mode>] ERROR

Defined values

<aoto> 0 – disable auto report 1 – enable auto report

<mode> 0 – CSQ auto report every five seconds 1 – CSQ auto report only after <rssi> or <ber> changing

NOTE If the parameter of <mode> is omitted when executing write command, <mode> will be set to default value.

Examples

AT+AUTOCSQ=? +AUTOCSQ: (0-1),(0-1) OK AT+AUTOCSQ? +AUTOCSQ: 1,1 OK AT+AUTOCSQ=1,1 OK +CSQ: 23,0 (when <rssi> or <ber> changing)

7.8 AT+CACM Accumulated call meter

Description The command resets the Advice of Charge related accumulated call meter value in SIM file EFACM.

SIM PIN References

Page 168: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 167

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CACM=? OK

Read Command Responses +CACM: <acm> OK

ERROR

AT+CACM?

+CME ERROR: <err>

Write Command Responses OK

ERROR

AT+CACM=<passwd>

+CME ERROR: <err>

Execution Command Responses

OK AT+CACM

+CME ERROR: <err>

Defined values

<passwd> String type, SIM PIN2. <acm> String type, accumulated call meter value similarly coded as <ccm> under +CAOC.

Examples

AT+CACM? +CACM: "000000" OK

7.9 AT+CAMM Accumulated call meter maximum

Description The command sets the Advice of Charge related accumulated call meter maximum value in SIM file EFACMmax.

SIM PIN References

YES 3GPP TS 27.007

Page 169: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 168

Syntax

Test Command Responses AT+CAMM=? OK

Read Command Responses +CAMM: <acmmax> OK

ERROR

AT+CAMM?

+CME ERROR: <err>

Write Command Responses OK

ERROR

AT+CAMM= <acmmax>[,<passwd>]

+CME ERROR: <err> Execution Command Responses

OK AT+CAMM

+CME ERROR: <err>

Defined values

<acmmax> String type, accumulated call meter maximum value similarly coded as <ccm> under AT+CAOC, value zero disables ACMmax feature. <passwd> String type, SIM PIN2.

Examples

AT+CAMM? +CAMM: "000000" OK

7.10 AT+CPUC Price per unit and currency table

Description The command sets the parameters of Advice of Charge related price per unit and currency table in SIM file EFPUCT.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Page 170: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 169

Test Command Responses AT+CPUC=? OK

Read Command Responses +CPUC: [<currency>,<ppu>] OK

ERROR

AT+CPUC?

+CME ERROR: <err>

Write Command Responses OK

ERROR

AT+CPUC=<currency>, <ppu>[,<passwd>]

+CME ERROR: <err>

Defined values

<currency> String type, three-character currency code (e.g. "GBP", "DEM"), character set as specified by command Select TE Character Set AT+CSCS. <ppu> String type, price per unit, dot is used as a decimal separator. (e.g. "2.66"). <passwd> String type, SIM PIN2.

Examples

AT+CPUC? +CPUC: “GBP”,2.66 OK

7.11 AT+CPOF Control phone to power down

Description The command controls the phone to power off.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CPOF=? OK

Execution Command Responses

Page 171: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 170

AT+CPOF OK

Examples

AT+CPOF OK

7.12 AT+CCLK Real time clock

Description The command is used to manage Real Time Clock of the module.

SIM PIN References

NO 3GPP TS 27.007

Syntax

Test Command Responses AT+CCLK=? OK

Read Command Responses AT+CCLK? +CCLK: <time>

OK

Write Command Responses OK AT+CCLK=<time>

ERROR

Defined values

<time> String type value; format is “yy/MM/dd,hh:mm:ss±zz”, where characters indicate year (two last digits), month, day, hour, minutes, seconds and time zone (indicates the difference, expressed in quarters of an hour, between the local time and GMT; three last digits are mandatory, range -47…+48). E.g. 6th of May 2008, 14:28:10 GMT+8 equals to “08/05/06,14:28:10+32”. NOTE 1. Time zone is nonvolatile, and the factory value is invalid time zone. 2. Command +CCLK? will return time zone when time zone is valid, and if time zone is

00, command +CCLK? will return “+00”, but not “-00”.

Examples

AT+CCLK=”08/11/28, 12:30:33+32” OK AT+CCLK? +CCLK: "08/11/28,12:30:35+32"

Page 172: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 171

OK AT+CCLK=”08/11/26,10:15:00” OK AT+CCLK? +CCLK: “08/11/26,10:15:02+32” OK

7.13 AT+CRFEN RF check at initialization

Description The command will enable or disable RF check at the initialization, you can disable the RF

control status check at the initialization if do not want to check the RF pin status. This status will be saved the check function on reboot. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CRFEN=? +CRFEN: (list of supported <value>s)

OK

Read Command Responses AT+CRFEN? +CRFEN:<value>

OK

Write Command Responses OK AT+CRFEN= <value>

ERROR

Defined values

<value> 0 – disable RF check at initialization 1 – enable RF check at initialization

Examples

AT+CRFEN=1 OK AT+CRFEN? +CRFEN: 1 OK

Page 173: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 172

AT+CRFEN=? +CRFEN : (0-1) OK

7.14 AT+CRESET Reset ME

Description The command is used to reset ME.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CRESET=? OK

Execute Command Responses AT+CRESET OK

Examples

AT+CRESET=? OK AT+CRESET OK

7.15 AT+SIMEI Set module IMEI

Description The command is used to set module IMEI value.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+SIMEI=? OK

Read Command Responses

Page 174: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 173

AT+SIMEI? +SIMEI: <imei> OK

Write Command Responses OK AT+SIMEI=<imei>

ERROR

Defined values

<imei> The 15-digit IMEI value.

Examples

AT+SIMEI=357396012183170 OK AT+SIMEI? +SIMEI: 357396012183170 OK AT+SIMEI=? OK

7.16 AT+CSIMLOCK Request and change password

Description The command allows to request a password and define a new password for a password protected

<facility> lock function.Each password is a string of digits, the length is 8.The read command returns status of <facility> lock. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CSIMLOCK=? +CSIMLOCK: (list of supported <facility>s)

OK

Read Command Responses AT+CSIMLOCK? +CSIMLOCK: <PN_status>,<PU_status>,<PP_status>,<PC_status

>,<PF_status> OK

Write Command Responses AT+CSIMLOCK= <facility> +CSIMLOCK: <old password>

Page 175: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 174

OK [,<old password>,<new password>]

+CME ERROR: <err>

Defined values

<facility> “PN” Network Personalisation “PU” Network subset Personalisation “PP” Service Provider Personalisation “PC” Corporate Personalisation “PF” Lock Phone to the very First SIM card

<old password> Password specified for the facility. The length of password is 8. <new password> New password for the facility.The length of password is 8. <PN_status>

Status of “PN” lock 0 inactive 1 autolock 2 active 5 disable

<PU_status> Status of “PU” lock

0 inactive 1 autolock 2 active 5 disable

<PP_status> State of “PP” lock

0 inactive 1 autolock 2 active 5 disable

<PC_status> State of “PC” lock

0 inactive 1 autolock 2 active 5 disable

<PF_status> State of “PF” lock

0 inactive

Page 176: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 175

1 autolock 2 active 5 disable

Examples

AT+CSIMLOCK=? +CSIMLOCK: ("PN","PU","PP","PC","PF") OK AT+CSIMLOCK? +CSIMLOCK: 0,0,0,0,0 OK AT+CSIMLOCK=”PN” +CSIMLOCK: 87654321 OK AT+CSIMLOCK=”PN”,”87654321”,”12345678” OK

7.17 AT+DSWITCH Change diagnostics port mode

Description The command is used to change diagnostics port mode.The default mode of diagnostics port is debug mode. You can switch it from debug mode to data mode or from data mode to debug mode.In data mode, you can send and receive PCM data. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+DSWITCH=? +DSWITCH: (list of supported <mode>s)

OK

Read Command Responses AT+DSWITCH? +DSWITCH: <mode>

OK

Write Command Responses OK AT+DSWITCH =<mode>

ERROR

Defined values

<mode>

Page 177: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 176

Pamameter shows the settings of diagnostics port 0 Switch from data mode to debug mode 1 Switch from debug mode to data mode

Examples

AT+DSWITCH=? +DSWITCH: (0-1) OK AT+DSWITCH? +DSWITCH: 0 OK AT+DSWITCH=1 OK

7.18 AT+CNVW Write NV item

Description The AT+CNVW write command can be used to write <item> to NV(nonvolatile memory).If <item> is given as the only parameter,the write command may get <item> information. The test command returns the range of <item> and the maximum length of the <item_data> field. NOTE Before writing <item> to NV,you should get <item> information by AT+CNVW=<item> and confirm these parameters. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CNVW=? +CNVW: (0-<max_item>),<max_data_len>

OK

Write Command Responses If <item> is given as the only parameter: +CNVW: <item>,<presence>,<array_size>,<item_size> OK

If successful,return: +CNVW: 1 OK

AT+CNVW=<item>[,<index>,<item_data>]

If fail,return: +CNVW: 0,<err_code> OK

Page 178: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 177

Defined values

<max_item> Maximum number of item supported by module. <max_data_len> Maximum length of <item_data>. <item> Item number in NV(nonvolatile memory).These items store some configuration of RF,Audio,etc. <index> Index of array.Some items is stored by array.When operating these items,you must specify the index.To other items(not stored by array),the index is 0. <item_data> Data(string type) that written to <item>.<item_data> is in hexadecimal format.The length of <item_data> is not more than <item_size>*2. <presence> Presence of item. 0 not present 1 present <array_size> Size of array.If <item> is stored by array,the value of <index> must be less than <array_size>. <item_size> Size of item.The value is given in octets.Because the format of <item_data> is hexadecimal,the length of <item_data> should be equal to <item_size>*2. <err_code> The error codes.These error codes are followed: -1 Error parameters

0 Not present 1 Busy(Request is queued) 2 Bad(unrecognizable) command 3 The NVM is full 4 Command failed,reason other than NVM was full 5 Not active 6 Bad parameter in command block 7 Parameter is write-protected and thus read only. 8 Item not valid for target 9 Free memory exhausted 10 Address is not a valid allocation.

Examples

AT+CNVW=? +CNVW: (0-7157),256 OK AT+CNVW=110

Page 179: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 178

+CNVW: 110,1,0,1 OK AT+CNVW=110,0,"00" +CNVW: 1 OK

7.19 AT+CNVR Read NV item

Description The AT+CNVR write command can be used to get <item> data from NV(nonvolatile memory).If <item> is given as the only parameter,the write command may get <item> information. The test command returns the range of <item> and the maximum length of the <item_data> field. NOTE Before reading <item> from NV,you should get <item> information by AT+CNVR=<item> and confirm these parameters. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CNVR=? +CNVR: (0-<max_item>),<max_data_len>

OK

Write Command Responses If <item> is given as the only parameter: +CNVR: <item>,<presence>,<array_size>,<item_size> OK

If successful,return: +CNVR: 1,<item_data> OK

AT+CNVR=<item>[,<index>]

If fail,return: +CNVR: 0,<err_code> OK

Defined values

<max_item> Maximum number of item supported by module.

<max_data_len> Maximum length of <item_data>.

<item>

Page 180: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 179

Item number in NV(nonvolatile memory).These items store some configuration of RF,Audio,etc. <index> Index of array.Some items is stored by array.When operating these items,you must specify the index.To other items(not stored by array),the index is 0. <item_data> Data(string type) that written to <item>.<item_data> is in hexadecimal format.The length of <item_data> is not more than <item_size>*2. <presence>

Presence of item. 0 not present 1 present <array_size>

Size of array.If <item> is stored by array,the value of <index> must be less than <array_size>. <item_size>

Size of item.The value is given in octets.Because the format of <item_data> is hexadecimal,the length of <item_data> should be equal to <item_size>*2. <err_code>

The error codes.These error codes are followed: -1 Error parameters

0 Not present 1 Busy(Request is queued) 2 Bad(unrecognizable) command 3 The NVM is full 4 Command failed,reason other than NVM was full 5 Not active 6 Bad parameter in command block 7 Parameter is write-protected and thus read only. 8 Item not valid for target 9 Free memory exhausted 10 Address is not a valid allocation.

Examples

AT+CNVR=? +CNVR: (0-7157),256 OK AT+CNVR=110 +CNVR: 110,1,0,1 OK AT+CNVR=110,0 +CNVR: 1,"00" OK

Page 181: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 180

7.20 AT+CDELTA Write delta package to FOTA partition

Description The AT+CDELTA command can be used to write delta package to FOTA partition. After writing successfully, it will set the flag for updating. When module resets and checks the flag, then it starts to update firmware. The delta package is saved as a file in file system. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CDELTA=? OK

Write Command Responses If successful,return: +CDELTA: 1 OK

AT+CDELTA=<delta_package>

If fail,return: +CDELTA: 0,<err_code> OK

Defined values

<delta_package> File name of delta package (string type). <delta_package> must be double quoted.

Please refer to “NOTE” section for more detail. <err_code>

The error code of writing delta package. 0 The delta package does not exist 1 Error occurs when reading delta package 2 Error occurs when writing delta package to FOTA partition 3 Set the flag of updating unsuccessfully

Examples

AT+CDELTA=? OK AT+CDELTA=”delta_1_2.mld” +CDELTA: 1 OK

NOTE: 1. Delta package can be resided in the module or T Flash card, this command will lookup the package

Page 182: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 181

under current directory. BTW you can use +FSCD to change current directory. 2. After the command finished one need to reset the module to start the updating process, during the

process the status led will blink for attention. Please refer “SIM52xx_Delta_Package_Update_Application_note_V0.01.doc” for more detail.

7.21 AT+CDIPR Set UART baud rate

Description The command sets UART baud rate when upgrade firmware through UART. NOTE: 1. This command depends on which baud rate is set by AT+IPR and download tool. 2. Before using download tool to upgrade firmware through UART, one must use AT+CUDIAG to

change UART service for download. 3. The baud rate will be saved as long as this command is executed. 4. Please refer to the document about download firmware through UART, in order to get more

usage of this command. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CDIPR=? +CDIPR:(0-3)

OK

Read Command Responses AT+CDIPR? +CDIPR: <value>

OK

Write Command Responses OK AT+CDIPR=<value>

ERROR Execution Command Responses AT+CDIPR Set default value:

OK

Defined values

<value> The baud rate which will be set. 0 – 38400 1 – 57600 2 – 115200(default)

Page 183: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 182

3 – 230400

Examples

AT+CDIPR? +CDIPR: 2 OK AT+CDIPR=? +CDIPR: (0-3) OK AT+CDIPR=2 OK

7.22 AT+CUDIAG Switch UART from AT service to DIAG service

Description The command switches UART from AT service to DIAG service. After executing this command, UART comport can’t be used to send AT command, and just used to transmit and receive data. NOTE: This command must be used by the UART comport which is current used port. SIM PIN References

NO Vendor

Syntax

Execution Command Responses AT+CUDIAG OK

Examples

AT+CUDIAG OK

7.23 AT+CUDLOADS Switch to UART download mode

Description

The command switch upgrade mode from USB download mode to UART download mode. Notice: 1. The default download mode is through USB, this command is used when one wants to use

UART to upgrade firmware. 2. When use AT+CUDLOADS=1, USB can never be used to upgrade firmware. 3. When one set this command “1”, after UART download finished, this command will be “0”,

and next download mode will be USB download mode.

Page 184: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 183

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CUDLOADS=? +CUDLOADS: (0-1)

OK

Read Command Responses AT+CUDLOADS? +CUDLOADS: <value>

OK

Write Command Responses OK AT+CUDLOADS=<value>

ERROR Execution Command Responses AT+CUDLOADS Set default value:

OK

Defined values

<value> The download mode which will be set. 0 – USB download mode. 1 – UART download mode.

Examples

AT+CUDLOADS? +CUDLOADS: 0 OK AT+CUDLOADS=? +CUDLOADS: (0-1) OK AT+CUDLOADS=1 OK

NOTE: Please refer to the application note “SIM52xx_UART_Dload_Application_note_V0.02.doc”, in order to get more usage of this command.

Page 185: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 184

8 SIMCard Related Commands

8.1 AT+CICCID Read ICCID in SIM card

Description The command is used to Read the ICCID in SIM card

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CICCID=? OK

Execution Command Responses +ICCID:<ICCID> OK

ERROR

AT+CICCID

+CME ERROR: <err>

Defined values

<ICCID> Integrate circuit card identity, a standard ICCID is a 20-digit serial number of the SIM card, it presents the publish state, network code, publish area, publish date, publish manufacture and press serial number of the SIM card.

Examples

AT+CICCID +ICCID: 898600700907A6019125 OK

8.2 AT+CSIM Generic SIM access

Description

Page 186: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 185

The command allows to control the SIM card directly. Compared to restricted SIM access command AT+CRSM, AT+CSIM allows the ME to take more control over the SIM interface. For SIM–ME interface please refer 3GPP TS 11.11. NOTE The SIM Application Toolkit functionality is not supported by AT+CSIM. Therefore the

following SIM commands can not be used: TERMINAL PROFILE, ENVELOPE, FETCH and TEMINAL RESPONSE.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CSIM=? OK

Write Command Responses +CSIM: <length>, <response> OK

ERROR

AT+CSIM= <length>,<command>

+CME ERROR: <err>

Defined values

<length> Interger type; length of the characters that are sent to TE in <command> or <response> <command> Command passed on by the MT to the SIM. <response> Response to the command passed on by the SIM to the MT.

Examples

AT+CSIM=? OK

8.3 AT+CRSM Restricted SIM access

Description

Page 187: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 186

By using AT+CRSM instead of Generic SIM Access AT+CSIM, TE application has easier but more limited access to the SIM database. Write command transmits to the MT the SIM <command> and its required parameters. MT handles internally all SIM-MT interface locking and file selection routines. As response to the command, MT sends the actual SIM information parameters and response data. MT error result code +CME ERROR may be returned when the command cannot be passed to the SIM, but failure in the execution of the command in the SIM is reported in <sw1> and <sw2> parameters.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CRSM=? OK

Write Command Responses +CRSM: <sw1>,<sw2>[,<response>] OK

ERROR

AT+CRSM=<command> [,<fileID>[,<p1>,<p2>, <p3> [,<data>]]]

+CME ERROR: <err>

Defined values

<command> Command passed on by the MT to the SIM:

176 – READ BINARY 178 – READ RECORD 192 – GET RESPONSE 214 – UPDATE BINARY 220 – UPDATE RECORD 242 – STATUS 203 – RETRIEVE DATA 219 – SET DATA

<fileID> Identifier for an elementary data file on SIM, if used by <command>. The follow list the fileID hex value, the user need to convet them to decimal. EFs under MF 0x2FE2 ICCID 0x2F05 Extended Language Preferences 0x2F00 EF DIR 0x2F06 Access Rule Reference EFs under USIM ADF

0x6F05 Language Indication

Page 188: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 187

0x6F07 IMSI 0x6F08 Ciphering and Integrity keys 0x6F09 C and I keys for pkt switched domain 0x6F60 User controlled PLMN selector w/Acc Tech 0x6F30 User controlled PLMN selector 0x6F31 HPLMN search period 0x6F37 ACM maximum value 0x6F38 USIM Service table 0x6F39 Accumulated Call meter 0x6F3E Group Identifier Level 0x6F3F Group Identifier Level 2 0x6F46 Service Provider Name 0x6F41 Price Per Unit and Currency table 0x6F45 Cell Bcast Msg identifier selection 0x6F78 Access control class 0x6F7B Forbidden PLMNs 0x6F7E Location information 0x6FAD Administrative data 0x6F48 Cell Bcast msg id for data download 0x6FB7 Emergency call codes 0x6F50 Cell bcast msg id range selection 0x6F73 Packet switched location information 0x6F3B Fixed dialling numbers 0x6F3C Short messages 0x6F40 MSISDN 0x6F42 SMS parameters 0x6F43 SMS Status 0x6F49 Service dialling numbers 0x6F4B Extension 2 0x6F4C Extension 3 0x6F47 SMS reports 0x6F80 Incoming call information 0x6F81 Outgoing call information 0x6F82 Incoming call timer 0x6F83 Outgoing call timer 0x6F4E Extension 5 0x6F4F Capability Config Parameters 2 0x6FB5 Enh Multi Level Precedence and Pri 0x6FB6 Automatic answer for eMLPP service 0x6FC2 Group identity 0x6FC3 Key for hidden phonebook entries 0x6F4D Barred dialling numbers 0x6F55 Extension 4

Page 189: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 188

0x6F58 Comparison Method information 0x6F56 Enabled services table 0x6F57 Access Point Name Control List 0x6F2C De-personalization Control Keys 0x6F32 Co-operative network list 0x6F5B Hyperframe number 0x6F5C Maximum value of Hyperframe number 0x6F61 OPLMN selector with access tech 0x6F5D OPLMN selector 0x6F62 HPLMN selector with access technology 0x6F06 Access Rule reference 0x6F65 RPLMN last used access tech 0x6FC4 Network Parameters 0x6F11 CPHS: Voice Mail Waiting Indicator 0x6F12, CPHS: Service String Table 0x6F13 CPHS: Call Forwarding Flag 0x6F14 CPHS: Operator Name String 0x6F15 CPHS: Customer Service Profile 0x6F16 CPHS: CPHS Information 0x6F17 CPHS: Mailbox Number 0x6FC5 PLMN Network Name 0x6FC6 Operator PLMN List 0x6F9F Dynamic Flags Status 0x6F92 Dynamic2 Flag Setting 0x6F98 Customer Service Profile Line2 0x6F9B EF PARAMS - Welcome Message 0x4F30 Phone book reference file 0x4F22 Phone book synchronization center 0x4F23 Change counter 0x4F24 Previous Unique Identifier 0x4F20 GSM ciphering key Kc 0x4F52 GPRS ciphering key 0x4F63 CPBCCH information 0x4F64 Investigation scan 0x4F40 MExE Service table 0x4F41 Operator Root Public Key 0x4F42 Administrator Root Public Key 0x4F43 Third party Root public key 0x6FC7 Mail Box Dialing Number 0x6FC8 Extension 6 0x6FC9 Mailbox Identifier 0x6FCA Message Waiting Indication Status 0x6FCD Service Provider Display Information

Page 190: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 189

0x6FD2 UIM_USIM_SPT_TABLE 0x6FD9 Equivalent HPLMN 0x6FCB Call Forwarding Indicator Status 0x6FD6 GBA Bootstrapping parameters 0x6FDA GBA NAF List 0x6FD7 MBMS Service Key 0x6FD8 MBMS User Key 0x6FCE MMS Notification 0x6FD0 MMS Issuer connectivity parameters 0x6FD1 MMS User Preferences 0x6FD2 MMS User connectivity parameters 0x6FCF Extension 8 0x5031 Object Directory File 0x5032 Token Information File 0x5033 Unused space Information File EFs under Telecom DF 0x6F3A Abbreviated Dialing Numbers 0x6F3B Fixed dialling numbers 0x6F3C Short messages 0x6F3D Capability Configuration Parameters 0x6F4F Extended CCP 0x6F40 MSISDN 0x6F42 SMS parameters 0x6F43 SMS Status 0x6F44 Last number dialled 0x6F49 Service Dialling numbers 0x6F4A Extension 1 0x6F4B Extension 2 0x6F4C Extension 3 0x6F4D Barred Dialing Numbers 0x6F4E Extension 4 0x6F47 SMS reports 0x6F58 Comparison Method Information 0x6F54 Setup Menu elements 0x6F06 Access Rule reference 0x4F20 Image 0x4F30 Phone book reference file 0x4F22 Phone book synchronization center 0x4F23 Change counter 0x4F24 Previous Unique Identifier <p1> <p2> <p3> Integer type; parameters to be passed on by the Module to the SIM. <data>

Page 191: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 190

Information which shall be written to the SIM(hexadecimal character format, refer AT+CSCS). <sw1> <sw2> Status information from the SIM about the execution of the actual command. It is returned in both cases, on successful or failed execution of the command. <response> Response data in case of a successful completion of the previously issued command. “STATUS” and “GET RESPONSE” commands return data, which gives information about the currently selected elementary data field. This information includes the type of file and its size. After “READ BINARY” or “READ RECORD” commands the requested data will be returned. <response> is empty after “UPDATE BINARY” or “UPDATE RECORD” commands.

Examples

AT+CRSM=? OK

8.4 AT+CSIMSEL Switch between two SIM card

Description The command is used to select external or embedded SIM card. NOTE 1. Embedded SIM card supported by customization. Customer should provide information

written into USIM chipset. 2. The command is disabled if the embedded SIM card isn’t exist, i.e. standard hardware

version. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CSIMSEL=? OK

Read Command Responses AT+CSIMSEL? +CSIMSEL: <simcard>

OK

Write Command Responses AT+CSIMSEL=<simcard> OK

Defined values

<simcard> 1 – external SIM card

Page 192: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 191

2 – embedded SIM card

Examples

AT+CSIMSEL=1 OK

8.5 AT+SPIC Times remain to input SIM PIN/PUK

Description The command is used to inquire times remain to input SIM PIN/PUK.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+SPIC=? OK

Execution Command Responses AT+SPIC +SPIC: <pin1>,<puk1>,<pin2>,<puk2>

OK

Defined values

<pin1> Times remain to input PIN1 code. <puk1> Times remain to input PUK1 code. <pin2> Times remain to input PIN2 code. <puk2> Times remain to input PUK2 code.

Examples

AT+SPIC=? OK AT+SPIC +SPIC: 3,10,0,10 OK

Page 193: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 192

8.6 AT+CSPN Get service provider name from SIM

Description This command is used to get service provider name from SIM card.

SIM PIN References

YES Vendor

Syntax

Test Command Responses OK AT+CSPN=?

ERROR

Read Command Responses +CSPN: <spn>,<display mode> OK

OK

AT+CSPN?

+CME ERROR: <err>

Defined values

<spn> String type; service provider name on SIM <display mode>

0 – don’t display PLMN.Already registered on PLMN. 1 – display PLMN

Examples

AT+CSPN=? OK AT+CSPN? +CSPN: “CMCC”,0 OK

9 Hardware Related Commands

9.1 AT+CTXGAIN Set TX gain

Description

Page 194: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 193

The command is used to set audio path parameter – TX gain, and refer to related hardware design document to get more information.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CTXGAIN=? +CTXGAIN: (list of supported <tx_gain>s)

OK Read Command Responses AT+CTXGAIN? +CTXGAIN: <tx_gain>

OK Write Command Responses AT+CTXGAIN=<tx_gain> OK

Defined values

<tx_gain> TX gain level which is from 0 to 65535.

Examples

AT+CTXGAIN=1234 OK

9.2 AT+CRXGAIN Set RX gain

Description The command is used to set audio path parameter – RX gain, and refer to related hardware design document to get more information.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CRXGAIN=? +CRXGAIN: (list of supported <rx_gain>s)

OK Read Command Responses AT+CRXGAIN? +CRXGAIN: <rx_gain>

Page 195: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 194

OK Write Command Responses AT+CRXGAIN=<rx_gain> OK

Defined values

<rx_gain> RX gain level which is from 0 to 65535.

Examples

AT+CRXGAIN=1234 OK

9.3 AT+CTXVOL Set TX volume

Description

The command is used to set audio path parameter – TX volume, and refer to related hardware design document to get more information.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CTXVOL=? +CTXVOL: (list of supported <tx_vol>s)

OK

Read Command Responses AT+CTXVOL? +CTXVOL: <tx_vol>

OK

Write Command Responses AT+CTXVOL=<tx_vol> OK

Defined values

<tx_vol> TX volume level which is from 0 to 65535.

Examples

AT+CTXVOL=1234 OK

Page 196: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 195

9.4 AT+CRXVOL Set RX volume

Description The command is used to set audio path parameter – RX volume, and refer to related hardware design document to get more information.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CRXVOL=? +CRXVOL: (list of supported <rx_vol>s)

OK

Read Command Responses AT+CRXVOL? +CRXVOL: <rx_vol>

OK

Write Command Responses AT+CRXVOL=<rx_vol> OK

Defined values

<rx_vol> RX volume level which is from -100 to 100.

Examples

AT+CRXVOL=12 OK

9.5 AT+CTXFTR Set TX filter

Description The command is used to set audio path parameter – TX filter, and refer to related hardware design document to get more information.

SIM PIN References

NO Vendor

Syntax

Test Command Responses

Page 197: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 196

AT+CTXFTR=? +CTXFTR: (list of supported <tx_ftr_N>s) OK

Read Command Responses AT+CTXFTR? +CTXFTR: <tx_ftr_1>,<…>,<tx_ftr_7>

OK

Write Command Responses AT+CTXFTR= <tx_ftr_1>,<…>,<tx_ftr_7>

OK

Defined values

<tx_ftr_X> TX filter level which is from 0 to 65535. (N is from 0 to 7)

Examples

AT+CTXFTR=1111,2222,3333,4444,5555,6666,7777 OK

9.6 AT+CRXFTR Set RX filter

Description The command is used to set audio path parameter – RX filter, and refer to related hardware design document to get more information.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CRXFTR=? +CRXFTR: (list of supported <rx_ftr_N>s)

OK

Read Command Responses AT+CRXFTR? +CRXFTR: <rx_ftr_1>,<…>,<rx_ftr_7>

OK

Write Command Responses AT+CRXFTR= <rx_ftr_1>,<…>,<rx_ftr_7>

OK

Defined values

Page 198: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 197

<rx_ftr_X> RX filter level which is from 0 to 65535. (N is from 0 to 7)

Examples

AT+CRXFTR=1111,2222,3333,4444,5555,6666,7777 OK

9.7 AT+CVALARM Low voltage Alarm

Description The command is used to open or close the low voltage alarm function.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CVALARM=? +CVALARM: (list of supported <enable>s), (list of supported

<voltage>s) OK

Read Command Responses AT+CVALARM? +CVALARM: <enable>,<voltage>

OK

Write Command Responses OK AT+CVALARM=<enable>[,

<voltage>] ERROR

Defined values

<enable> 0 – Close 1 – Open. If voltage < <voltage>, every 20 seconds will report a string: “warning! Voltage

is low:<voltage value>”. <voltage>

Between 2800mV and 4300mV. Default value is 3450. NOTE the two parameters will be saved automatically.

Examples

AT+CVALARM=1,3400 OK

Page 199: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 198

AT+CVALARM? +CVALARM: 1,3400 OK AT+CVALARM=? +CVALARM: (0-1),(2800-4300) OK

9.8 AT+CRIIC Read values from register of IIC device

Description Read values from register of IIC device.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CRIIC=? OK

Write Command Responses +CRIIC: <data> OK

AT+CRIIC= <addr>,<reg>,<len>

ERROR

Defined values

<addr> Device address. Input format must be hex, such as 0xFF. <reg> Register address. Input format must be hex, such as 0xFF. <len> Read length. Range:1-4; unit:byte. <data> Data read. Input format must be hex, such as 0xFF – 0xFFFFFFFF.

Examples

AT+CRIIC=0x0F, 0x0F, 2 +CRIIC: FFFF OK

Page 200: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 199

9.9 AT+CWIIC Write values to register of IIC device

Description Write values to register of IIC device.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CWIIC=? OK

Write Command Responses OK AT+CWIIC=

<addr>,<reg>,<data>,<len> ERROR

Defined values

<addr> Device address. Input format must be hex, such as 0xFF. <reg> Register address. Input format must be hex, such as 0xFF. <len> Read length. Range: 1-4; unit: byte. <data> Data written. Input format must be hex, such as 0xFF – 0xFFFFFFFF.

Examples

AT+CWIIC=0x0F, 0x0F, 0x1234, 2 +CWIIC: 0x1234 OK

9.10 AT+CVAUXS Set state of the pin named VREG_AUX1

Description The command is used to set state of the pin which is named VREG_AUX1.

SIM PIN References

NO Vendor

Syntax

Page 201: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 200

Test Command Responses AT+CVAUXS=? +CVAUXS: (list of supported <state>s)

OK

Read Command Responses AT+CVAUXS? +CVAUXS: <state>

OK

Write Command Responses OK AT+CVAUXS=<state>

ERROR

Defined values

<state> 0 – the pin is closed. 1 – the pin is opend(namely, open the pin)

Examples

AT+CVAUXS=1 OK AT+CVAUXS? +CVAUXS: 1 OK

9.11 AT+ CVAUXV Set voltage value of the pin named VREG_AUX1

Description The command is used to set the voltage value of the pin which is named VREG_AUX1.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CVAUXV=? +CVAUXV: (list of supported <voltage>s)

OK

Read Command Responses AT+CVAUXV? +CVAUXV: <voltage>

OK

Write Command Responses

Page 202: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 201

OK AT+CVAUXV=<voltage>

ERROR

Defined values

<voltage> Voltage value of the pin which is named VREG_AUX1. The unit is in 50*mV.

Examples

AT+CVAUXV=? +CVAUXV: (30-61) OK AT+CVAUXV=40 OK AT+CVAUXV? +CVAUXV: 40 OK

9.12 AT+CGPIO Set Trigger mode of interrupt GPIO

Description Set GPIO interrupt trigger mode (GPIO0 is used for interrupt).

SIM PIN References

NO Vendor

Syntax

Write Command Responses OK AT+CGPIO=<detect>,

<polarity>[,<save>] ERROR

Defined values

<detect> 0 – LEVEL trigger mode 1 – EDGE trigger mode

<polarity> 0 – trigger when low level 1 – trigger when high level

<save> 0 – not save the setting

Page 203: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 202

1 – save the setting NOTE If the parameter of <save> is omitted, it will save the setting.

Examples

AT+ CGPIO =1,1,0 OK

9.13 AT+CGDRT Set the direction of specified GPIO

Description The command is used to set the specified GPIO to in or out state. If setting the specified GPIO to in state, then it can not set the value of the GPIO to high or low.

SIM PIN References

NO Vendor

Syntax

Write Command Responses OK AT+CGDRT=<gpio_num>,

<gpio_io>[,<save>] ERROR

Defined values

<gpio_num> 0 – GPIO0 2 – GPIO2 3 – GPIO3 5 – GPIO5

<gpio_io> 0 – in

1 – out <save>

0 – not save the setting 1 – save the setting NOTE If the parameter of <save> is omitted, it will save the direction of specified GPIO.

Examples

AT+CGDRT=3,0,0 OK

Page 204: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 203

9.14 AT+CGSETV Set the value of specified GPIO

Description The command is used to set the value of the specified GPIO to high or low.

SIM PIN References

NO Vendor

Syntax

Write Command Responses OK AT+CGSETV=<gpio_num>,

<gpio_hl>[,<save>] ERROR

Defined values

<gpio_num> 0 – GPIO0 2 – GPIO2 3 – GPIO3

5 – GPIO5 <gpio_hl>

0 – low 1 – high <save> 0 – not save the setting 1 – save the setting NOTE If the parameter of <save> is omitted, it will save the value of specified GPIO.

Examples

AT+CGSETV=3,0,0 OK

9.15 AT+CGGETV Get the value of specified GPIO

Description The command is used to get the value (high or low) of the specified GPIO.

SIM PIN References

NO Vendor

Page 205: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 204

Syntax

Write Command Responses +CGGETV: <gpio_hl> OK

AT+CGGETV=<gpio_num>

ERROR

Defined values

<gpio_num> 0 – GPIO0

1 – GPIO1 2 – GPIO2 3 – GPIO3 4 – GPIO4

5 – GPIO5 <gpio_hl>

0 – low 1 – high

Examples

AT+CGGETV=3 +CGGETV: 0 OK

9.16 AT+CGISR set interrupt trigger condition and start such

interruption.

Description SIM52XX supplies many GPIOs, all of which can be used as General Purpose Input/Oupt pin, interrupt pin and some of them can be used as function pin.

This command is used to set one GPIO pin as an interrupt source. It sets the detect type and polarity type for such interruption and then enables the interruption. Please consult the document “SIM52xx_GPIO_Application_note” for more details.

SIM PIN References

No

Syntax

Read Command Responses

Page 206: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 205

AT+CGISR=<GPIO> +CGISR: <switch>[<detect>,<polarity>] OK

Write Command Responses AT+CGISR=< GPIO >,<detect>,<polarity>

OK

Defined values

< GPIO > GPIO number. < switch > 0 : interrupt is disabled. 1 : interrupt is enabled < detect > 0 : level detection. 1 : edge detection < polarity > 0 : low level/edge detection 1 : high level/edge detection

Examples

AT+CGISR=1,0,1 OK AT+CGISR=1? + CGISR : 1[0,1] OK

NOTE: 1. if the interruption is triggered SIM52XX will send the following URC to host.

2. for read command if < switch > is 0 then <detect>, <polarity> have no meaning.

9.17 AT+CADC Read ADC value

Description Read the ADC value from modem. We support 3 type of ADC, raw type, temperature type and voltage type.

SIM PIN References

NO Vendor

Page 207: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 206

Syntax

Test Command Responses AT+CADC=? +CADC: (range of supported <adc>s)

OK

Write Command Responses +CADC: <value> OK

AT+CADC=<adc>

ERROR

Execution Command Responses AT+CADC Same as AT+CADC= 0:

+CADC: <value> OK

Defined values

<adc> ADC type:

0 – raw type. 1 – temperature type. 2 – voltage type(mv)

<value> Integer type value of the ADC.

Examples

AT+CADC=? +CADC:(0-2) OK AT+CADC=0 +CADC: 187 OK

9.18 AT+CMICAMP1 Set value of micamp1

Description The command is used to set audio path parameter – micamp1; With this command you can change the first stage of MIC amplify value based on your design separately and refer to related hardware design document to get more information SIM PIN References

NO Vendor

Page 208: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 207

Syntax

Test Command Responses AT+CMICAMP1=? +CMICAMP1: (list of supported <amp_val>s)

OK

Read Command Responses AT+ CMICAMP1? +CMICAMP1:<amp_val>

OK

Write Command Responses OK AT+CMICAMP1=

<amp_val> ERROR

Defined values

<amp_val> Amplify value number which is from 0 to 1. 0 is 0DB and 1 is 24DB.

Examples

AT+CMICAMP1=0 +CMICAMP1: 0 OK AT+CMICAMP1? +CMICAMP1: 0 OK AT+ CMICAMP1=? +CMICAMP1: (0-1) OK

9.19 AT+CVLVL Set value of sound level

Description The command is used to set audio path parameter – RX volume; this command is different

from CRXVOL, command CRXVOL will modify the values of all sound levels offset we provided together. With this command you can change the value of each sound level based on your design separately and refer to related hardware design document to get more information. SIM PIN References

NO Vendor

Syntax

Test Command Responses

Page 209: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 208

AT+CVLVL=? +CVLVL: (list of supported <lvl>s),(list of supported <lvl_v-alue>s) OK

Read Command Responses AT+CVLVL? +CVLVL: <lvl_value1>,<lvl_value2>,<lvl_value3>,<lvl_value4>,

<lvl_value5>,<lvl_value6>,<lvl_value7>,<lvl_value8> OK

Write Command Responses OK AT+CVLVL= <lvl>,

<lvl_value> ERROR

Defined values

<lvl> Sound level number which is from 1 to 8.

<lvl_value> Sound level value which is from -5000 to 5000.

<lvl_value1> Sound level value that sound level number equals 1.

<lvl_value2> Sound level value that sound level number equals 2.

<lvl_value3> Sound level value that sound level number equals 3.

<lvl_value4> Sound level value that sound level number equals 4.

<lvl_value5> Sound level value that sound level number equals 5.

<lvl_value6> Sound level value that sound level number equals 6.

<lvl_value7> Sound level value that sound level number equals 7.

<lvl_value8> Sound level value that sound level number equals 8.

Examples

AT+CVLVL=1,-2000 +CVLVL: -2000 OK AT+CVLVL? +CVLVL: -2000,-200,500,1000 OK AT+ CVLVL=?

Page 210: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 209

+CVLVL: (1-8),(-5000~5000) OK

NOTE: Currently level 7 and level 8 are the same, which means the value set for one level also will set for the other automatically(they have the same values).

9.20 AT+SIDET Digital attenuation of sidetone

Description The command is used to set digital attenuation of sidetone. For more detailed information, please refer to relevant HD document.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+SIDET=? +SIDET: (list of supported <st>s)

OK

Read Command Responses AT+SIDET? +SIDET:<st>

OK

Write Command Responses OK AT+SIDET= <st>

ERROR

Defined values

<st> Digital attenuation of sidetone, integer type in decimal format and nonvolatile.

Range: from 0 to 65535. Factory value: HANDSET:4000, HEADSET:9472, SPEAKER PHONE:16384.

Examples

AT+CSDVC=1 OK AT+SIDET? +SIDET: 4000 OK

Page 211: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 210

9.21 AT+CECM Enable/Disable Echo Canceller

Description This command is used to select the echo cancellation mode. Each audio channel has own default echo cancellation mode. For example: Handset: at+cecm=1(default open) Headset: at+cecm=2(default open) Speaker: at+cecm=4(default open) PCM: at+cecm=5(default open) SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CECM=? +CECM: (list of supported <enable>s)

OK

Read Command Responses +CECM: <enable> AT+CECM?

OK

Write Command Responses OK AT+CECM=<enable>

ERROR

Defined values

<enable>: 0 : disable EC mode 1 : EC mode recommended for HANDSET 2 : EC mode recommended for HEADSET 3 : EC mode recommended for HANDSFREE 4 : EC mode recommended for SPEAKER 5 : EC mode recommended for BT HEADSET 6 : EC mode recommended for aggressive SPEAKER 7 : EC mode recommended for medium SPEAKER 8 : EC mode recommended for least aggressive SPEAKER

Note:

1. EC mode of 6, 7, 8 can be adjusted by +CECSET command 2. User should use this AT command together with other related audio AT commands like “CSDVC ”, “CPCM” and so on.

Page 212: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 211

Examples

AT+CECM=0 OK AT+ CECM =1 OK

9.22 AT+CNSM Enable/Disable Noise Suppression

Description This command is used to enable/disable noise suppression. The default value is enabled.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CNSM=? +CNSM: (list of supported <enable>s)

OK

Read Command Responses +CNSM: <enable> AT+CNSM?

OK

Write Command Responses OK AT+CNSM=<enable>

ERROR

Defined values

<enable>: 0 : disable this feature 1 : enable this feature

Note:

User should use this AT command together with other related audio AT commands like “CSDVC ”, “CPCM” and so on.

Examples

AT+CNSM=0 OK AT+ CNSM =1 OK

Page 213: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 212

9.23 AT+CECSET Adjust the effect for the given echo cancellation

mode

Description This command is used to adjust the parameters of the selected EC mode for the given device. It can be used together with +ECM command. This is a savable command. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CECSET=? +CECSET: (list of supported <index>s), (list of supported

<value>s) OK

Read Command Responses AT+CECSET? +CECSET:

current echo cancellation mode is : <ec_md> <index> -> <value> […] OK

Write Command Responses OK AT+CECSET

=<index>,<value> ERROR

Defined values

<ec_md>: Current echo cancellation mode, please refer +CECM for more details <index>:

0 – 37, EC has 38 parameters; this is the index of the selected parameter. <value>:

0 – 65535, EC parameter value. NOTE:

1. Currently only three EC mode’s parameters can be adjusted, they are 6, 7 and 8 you can use +ECM to select one of these modes. 2. You have to use +ECM to select the right EC mode first in order to change the parameters.

Examples

Page 214: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 213

AT+CSDVC=1 OK AT+CECM =6 OK AT+CECSET=0,65530 OK AT+CECSET=1,1000 OK

9.24 AT+CRIRS Reset RI pin of serial port

Description The command is used to reset RI pin of serial port (UART device).After the command executed. When a voice (csd, video) call or a SMS is coming or URC is reported, RI pin is asserted.it can wake up host. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CRIRS=? OK

Write Command Responses OK AT+CRIRS

ERROR

Defined values

None

Examples

AT+CRIRS OK

9.25 AT+CSUART Switch UART line mode

Description The command is used to switch UART line mode between three and seven lines mode.

SIM PIN References

Page 215: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 214

NO Vendor

Syntax

Test Command Responses AT+CSUART=? +CSUART: (list of supported <mode>s), (list of supported

<save>s) OK

Read Command Responses AT+CSUART? +CSUART: <mode>

OK

Write Command Responses OK AT+CSUART=<mode>[,<sa

ve>] ERROR

Defined values

<mode> 0 – 3 lines mode 1 – 7 lines mode

<save> 0 – don’t save the setting 1 – save the setting

Examples

AT+CSUART=1 OK

9.26 AT+CMUX Enable the multiplexer over the UART

Description This command is used to enable the multiplexer over the UART, after enabled four virtual com

ports can be used as DIAG port, NMEA port, AT command port or MODEM port(configured by +CMUXSRVPORT command) , the physical UART can no longer transfer data directly under this case.

By default all of the four virtual com ports are used as AT command port. SIM PIN References

NO Vendor

Syntax

Page 216: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 215

Test Command Responses AT+CMUX=? +CMUX: (0)

OK

Write Command Responses OK AT+CMUX=

<value>[,<subset>[,<port_speed>[,<N1>[,<T1>[,<N2>[,<T2>[,<T3>[,<k>]]]]]]]]

ERROR

Defined values

< value >: 0 – currently only 0 is supported(basic operation mode). < subset >: Currently omitted < port_speed >: Currently omitted, you can set speed before enable multiplexer < N1>: Currently omitted < T1>: Currently omitted < N2>: Currently omitted < T2>: Currently omitted < T3>: Currently omitted < k >: Currently omitted

Examples

AT+CMUX=0 OK

NOTE: Currently only basic operation mode has been supported

Page 217: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 216

9.27 AT+CMUXSRVPORT Configure the specific virtual com port to

the appropriate service

Description This command is used to configure the right service for the certain virtual com port; the setting

is savable and will be enabled on the next startup time. Default all of the virtual com ports are configured as DATA service.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CMUXSRVPORT=? +CMUXSRVPORT: (0-3),(0,1,5)

OK

Read Command Responses virtual port[<port>] - <service> AT+CMUXSRVPORT?

OK

Write Command Responses OK AT+CMUXSRVPORT=<po

rt>,<service> ERROR

Defined values

< port >: virtual com port 0 – 3 currently support 4 virtual com ports index from 0 to 3 < service >: valid service 0 – DIAG Service 1 – DATA(MODEM) Service 5 – NMEA Service

Examples

AT+CMUXSRVPORT=0,1 OK AT+CMUXSRVPORT=? +CMUXSRVPORT: (0-3),(0,1,5) OK

NOTE: DIAG and NMEA service are exclusively, so it is forbidden to configure the DIAG or NMEA service to more than one virtual com port.

Page 218: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 217

9.28 AT+CDCDMD Set DCD pin mode

Description The command is used to set DCD pin to DCD mode or GPIO mode. NOTE DCD mode is invalid currently. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CDCDMD=? +CDCDMD: (list of supported <mode>s)

OK

Read Command Responses AT+CDCDMD? +CDCDMD:<mode>

OK

Write Command Responses

OK AT+CDCDMD=<mode>

ERROR

Defined values

<mode> 0 – DCD mode 1 – GPIO mode

Examples

AT+CDCDMD=0 OK

9.29 AT+CDCDVL Set DCD pin high-low in GPIO mode

Description The command is used to set DCD pin high-low in GPIO mode. NOTE The command will disable when DCD pin is DCD mode. SIM PIN References

NO Vendor

Page 219: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 218

Syntax

Test Command Responses AT+CDCDVL=? +CDCDVL: (list of supported <value>s)

OK

Read Command Responses AT+CDCDVL? +CDCDVL:<value>

OK

Write Command Responses

OK AT+CDCDVL=<value>

ERROR

Defined values

<value> 0 – set DCD pin low in GPIO mode 1 – set DCD pin high in GPIO mode

Examples

AT+CDCDVL=0 OK

9.30 AT+CBC Battery charge

Description The command is used to query the voltage of power supply. NOTE The SIM5320 do not allow the detection of battery use,so <bcs> and <bcl> may be ignored.They are only compatible with other products like SIM5320,etc.The user can get the voltage of power supply by <vol>. SIM PIN References

NO 3GPP TS 07.07

Syntax

Test Command Responses AT+CBC=? +CBC: (list of supported <bcs>s),(list of supported <bcl>s)

OK

Execution Command Responses AT+CBC +CBC: <bcs>,<bcl>,<vol>V

OK

Page 220: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 219

+CME ERROR: <err>

Defined values

<bcs> 0 Battery powered

<bcl> 0…100 Battery charge level

<vol> Current voltage value (V).

Examples

AT+CBC=? +CBC: (0),(0-100) OK AT+CBC +CBC: 0,75,3.810V OK

9.31 AT+CDTRISRMD Configure the trigger condition for DTR’s

interrupt.

Description This command is used to set the appropriate trigger condition for DTR’s interrupt, which will finally waking up the module.

This command is only valid while the UART is under NULL modem mode. The interrupt is low level triggered by default.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CDTRISRMD=? +CDTRISRMD: (list of supported <detect>s),(list of supported

<polarity>s) OK

Read Command Responses AT+CDTRISRMD? +CDTRISRMD: <detect>,<polarity>

OK

Write Command Responses

Page 221: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 220

OK AT+CDTRISRMD =<detect>,<polarity> ERROR

Defined values

<detect> 0 Level trigger 1 Edge trigger

<polarity> 0 Low trigger 1 High trigger

Examples

AT+CDTRISRMD=0,1 OK AT+CDTRISRMD=0,0 OK

9.32 AT+CDTRISRS Enable/disable the pin of DTR’s awakening

function

Description This command is used to enable or disable the function of waking up the module by means of UART’s DTR pin which to trigger an interrupt

This command will only take effect while the UART is working under NULL modem mode. The function is disabled by default.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CDTRISRS=? +CDTRISRS: (list of supported <switch>s)

OK

Read Command Responses AT+CDTRISRS? +CDTRISRS: <switch>

OK

Write Command Responses AT+CDTRISRS =<switch> OK

Page 222: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 221

Defined values

<switch> 0 disable such function 1 enable such function

Examples

AT+CDTRISRS=1 OK AT+CDTRISRS=0 OK

9.33 AT+CGFUNC Enable/disable the function for the special GPIO.

Description SIM5320 supplies many GPIOs, all of which can be used as General Purpose Input/Output pin, interrupt pin and some of them can be used as function pin.

This command is used to enable/disable the function for the special GPIO. Please consult the document “SIM5320_GPIO_Application_note” for more details.

This command is savable.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CGFUNC=? +CGFUNC: (list of supported <function>s),(list of supported

<switch>s) OK

Read Command Responses AT+CGFUNC=<function> +CGFUNC: <switch>

OK

Write Command Responses AT+CGFUNC=<function>, <switch>

OK

Defined values

<function> 1 : function status led. 2 : function wakeup me

Page 223: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 222

3 : function wakeup host 4 : function pcm 7 : function keypad 9 : function rf switch 10 : function uart1 dcd 11 : function uart1 flow control 12: function wake up SIM5320 module by GPIO43 13: function wake up host by GPIO41 14:function module power up status(GPIO40) 17:function RI line 2G mode control, please see the detail from NOTE <switch> 0 : disable the function. 1 : enable the function

Examples

AT+CGFUNC=1,1 OK AT+CGFUNC=1 +CGFUNC: 1 OK

NOTE: 1 .Not all of the Modules of SIM52XX series have the whole upper functions; some may have camera

function while others may have keypad function and so on, please refer the Module SPEC for more details. 2. If AT+CGFUNC=17,1 then assert 60ms when have urc reported;assert 120m when have sms

received;and always asserted during the ring(incoming call).

9.34 AT+CGWHOST Reset GPIO 41 to high level

Description The command resets GPIO41 to high lever after waking up the HOST. GPIO41 status:

Low level: Wake up the HOST. High level: the default status, and HOST use this AT to reset GPIO41 to high level.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CGWHOST OK

Examples

Page 224: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 223

AT+CGWHOST OK

9.35 AT+CGWISRMD Configure the trigger condition for GPIO43’s

Description This command is used to set the appropriate trigger condition for GPIO43’s interrupt, which will finally waking up the module.

The interrupt is low level triggered by default. Note: Before using this AT to set triggered mode, please use “AT+CGFUNC=12,0” to disable the

function of GPIO43’s interrupt. After setting triggered mode, please use “AT+CGFUNC=12,1” to enable the function. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CGWISRMD=? +CGWISRMD: (list of supported <detect>s),(list of supported

<polarity>s) OK

Read Command Responses AT+CGWISRMD? +CGWISRMD: <detect>,<polarity>

OK

Write Command Responses OK AT+CGWISRMD

=<detect>,<polarity> ERROR

Defined values

<detect> 0 Level trigger 1 Edge trigger

<polarity> 0 Low trigger 1 High trigger

Examples

AT+CGWISRMD=0,1 OK AT+CGWISRMD=0,0

Page 225: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 224

OK

9.36 AT+CKGSWT Switch pins’ function

Description This command is used to switch pins’ function between keypad interface and general GPIO. If no keypad subsystem, the total 10 pins can be used as general GPIO after switching mode successfully.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CKGSWT=? +CKGSWT: (list of supported <mode>s)

OK

Read Command Responses AT+CKGSWT? +CKGSWT: <mode>

OK

Write Command Responses AT+CKGSWT=<mode> OK

Defined values

<mode> Integer type and nonvolatile value.

0 – General GPIO mode. 1 – Keypad interface mode (factory value). NOTE In general GPIO mode, GPIO AT command can be used to config the GPIOs’ direction and value (Refer to related HD document for more information).

KEYPAD INTERFACE <-----------> GENERAL GPIO NUMBER

KEYPAD_4 GPIO6

KEYPAD_3 GPIO7

KEYPAD_2 GPIO8

KEYPAD_1 GPIO9

KEYPAD_0 GPIO10

KEYSENSE4 GPIO11

KEYSENSE3 GPIO12

KEYSENSE2 GPIO13

KEYSENSE1 GPIO14

KEYSENSE0 GPIO15

Page 226: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 225

Examples

AT+CKGSWT=0 OK AT+CKGSWT=1 OK

9.37 +KEY Keypad result code

Description URCs (Unsolicited Result Code) for keypad when keypad interface mode is active (refer to +CKGSWT). Both key press and key release generate a URC. Refer to related HD document for more information about keypad. SIM PIN References

NO Vendor

Syntax

Unsolicited Result Code +KEY: <key>, [<key_row>, <key_column>], “<key_text>”

Defined values

<key> Key code in hexadecimal fomat (e.g. 0x0A). <key_row> Key row number. <key_column> Key column number. <key_text> The key text on EVB (Evaluation Board) for reference.

KEY VALUE REFERENCE <key> <key_row> <key_column> <key_text> 0x01 2 4 "MSG" 0x02 1 3 "#" 0x03 1 1 "*" 0x04 1 2 "0" 0x05 4 1 "1" 0x06 4 2 "2" 0x07 4 3 "3" 0x08 3 1 "4" 0x09 3 2 "5"

Page 227: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 226

0x0A 3 3 "6" 0x0B 2 1 "7" 0x0C 2 2 "8" 0x0D 2 3 "9" 0x0E 1 0 "BACK" 0x0F 4 0 "REJECT" 0x10 3 4 "UP" 0x11 0 4 "DOWN" 0x12 1 4 "CALL" 0x13 3 0 "MENU" 0x14 4 4 "SELECT" 0x15 0 0 "HANDFREE" 0x16 0 2 "NAMES" 0x17 0 3 "V+" 0x18 0 1 "V-" 0x19 2 0 "SET" 0xFF row and column is same as the key pressed "RELEASE"

Examples

(Press the menu key, and then release the key): +KEY: 0x13, [3, 0], "MENU" +KEY: 0xFF, [3, 0], "RELEASE"

9.38 AT+CUSBSPD Switch USB high or full speed

Description This command is used to switch the speed of USB between high speed and full speed. If you just want to use full speed to simplify the circuit then you can use this command to switch the USB speed. This command will save your configuration so if you don’t change the speed the module will use the latest configuration forever. This command will only takes effect on the next start-up. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CUSBSPD=? +CUSBSPD: (list of supported <speed>s)

OK

Read Command Responses AT+CUSBSPD? +CUSBSPD: <speed>

Page 228: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 227

OK

Write Command Responses OK AT+CUSBSPD=<speed>

ERROR

Defined values

<speed> Integer type and nonvolatile value.

0 – High speed 1 – Full speed (default value)

Examples

AT+CUSBSPD=? +CUSBSPD: (0-1) OK AT+CUSBSPD=0 OK AT+CUSBSPD=1 OK

9.39 AT+CLEDITST Adjust the LED’s intensity

Description This command is used to adjust the intensity of the LED. It also can be used to disable the driver. This is a savable command and the default value is 10 (100mA). SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CLEDITST=? +CLEDITST: (list of supported <led_type>s), (list of supported

<val>s) OK

Read Command Responses +CLEDITST: <val> AT+CLEDITST?

OK

Write Command Responses AT+CLEDITST=<led_type> OK

Page 229: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 228

,<val> ERROR

Defined values

<led_type> 0 : LCD <val>

0 : 0mA (disable driver) 1 : 10mA 2 : 20mA 3 : 30mA 4 : 40mA 5 : 50mA 6 : 60mA 7 : 70mA 8 : 80mA 9 : 90mA

10 : 100mA 11 : 110mA 12 : 120mA 13 : 130mA 14 : 140mA 15 : 150mA

Examples

AT+CLEDITST=0,0 OK AT+ CLEDITST =0,10 OK

9.40 AT+CADCA Read the value from the second ADC

Description The modem supports two ADCs, and this command is used to read the voltage value from the second ADC.

SIM PIN References

NO Vendor

Syntax

Execution Command Responses

Page 230: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 229

AT+CADCA +CADCA: <value> OK

Defined values

<value> Integer type value of the voltage.

Examples

AT+CADCA +CADCA: 1100 OK

9.41 AT+CAPWRON auto power on setting

Description You can use this command to let the module to be powered up automaticly at the appointed time.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CAPWRON=? +CAPWRON: (0-23), (0-59),(0-1)

OK

Read Command Responses AT+ CAPWRON? +CAPWRON: <hour>,<minute>,<repeated>

OK

Write Command Responses OK AT+CAPWRON=<hour>,<

minute>,<repeated> ERROR

Defined values

<hour> 0 – 23 : the hour to power up <minute> 0 – 59 : the minute to power up <repeated> 0 : not repeated.

Page 231: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 230

1 : repeated every day.

Examples

AT+CAPWRON=8,30,0 OK AT+CAPWRON? +CAPWRON: 8,30,0 OK AT+CAPWRON=? +CAPWRON: (0-23),(0-59),(0-1) OK

NOTE: You can use the command AT+CAPWRON=255,255,255 to cancel such function.

9.42 AT+CAPWROFF auto power off setting

Description You can use this command to let the module to be powered down automaticly at the appointed time.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CAPWROFF=? +CAPWROFF: (0-23), (0-59),(0-1)

OK

Read Command Responses AT+ CAPWROFF? +CAPWROFF: <hour>,<minute>,<repeated>

OK

Write Command Responses OK AT+CAPWROFF=<hour>,<

minute>,<repeated> ERROR

Defined values

<hour> 0 – 23 : the hour to power down <minute> 0 – 59 : the minute to power down <repeated>

Page 232: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 231

0 : not repeated. 1 : repeated every day.

Examples

AT+CAPWROFF=22,30,0 OK AT+CAPWROFF? +CAPWROFF: 22,30,0 OK AT+CAPWROFF=? +CAPWROFF: (0-23),(0-59),(0-1) OK

NOTE: You can use the command AT+CAPWROFF=255,255,255 to cancel such function

9.43 AT+CBVTBP Set 800-850 band indicator

Description This command is used to set the band indicator to 800 or 850 for the common RF channels of 800 and 850.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CBVTBP=? +CBVTBP: (0,1)

OK

Read Command Responses

+CSVM: <ind>

OK

AT+CBVTBP?

ERROR

Write Command Responses

OK AT+CBVTBP=<ind>

ERROR

Defined values

Page 233: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 232

<ind> 0 – The common RF channels of 800/850 is regarded as 850 1 – The common RF channels of 800/850 is regarded as 800

Examples

AT+CBVTBP? +CBVTBP: 1 OK AT+CBVTBP=1 OK

9.44 AT+CRFOP Set the value of RF output power

Description This command is used to set the value of RF output power for different bands supported by the module. SIM PIN References

NO Vendor

Syntax

Write Command Responses [+CRFOP: <band>,<value>] OK

AT+CRFOP=<band> [,<enable>] [,<value>]

ERROR

Defined values

<band> 0 – GSM 850 1 – GSM 900 2 – DCS 1800 3 – PCS 1900 4 – WCDMA 850 5 – WCDMA 900 6 – WCDMA 1900 7 – WCDMA 2100

<enable> 0 – write the third parameter <value> to the module 1 – write the default value to the module (the third parameter is not needed)

Page 234: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 233

<value> (0–3400) – the range for <band> 0-<band> 3 , it means 0 dbm to 34 dbm (0–200) – the range for <band> 4-<band> 7 , it means 8 dbm to 28 dbm

Examples

AT+ CRFOP =1 +CRFOP:1,3250 OK AT+ CRFOP =1,1 OK AT+ CRFOP =1,0,3100 OK

Page 235: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 234

10 SPI Related Commands

10.1 AT+CSPISETCLK SPI clock rate setting

Description The command is used to set SPI clock configuration and trigger mode.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CSPISETCLK=? +CSPISETCLK: (range of supported <polarity>s), (range of su

pported <mode>s),(range of supported <trigger mode>s) OK

Read Command Responses AT+CSPISETCLK? +CSPISETCLK: <polarity>,<mode>,<trigger mode>

OK

Write Command Responses OK AT+CSPISETCLK=<polarit

y>,<mode>,<trigger mode> ERROR

Defined values

<polarity> 0 the SPI clock signal is low when the clock is idle

1 the SPI clock signal is high when the clock is idle <mode> 0 the SPI clock runs only during a transfer unit

1 the SPI clock runs continuously from the start of the transfer <trigger mode> 0 the SPI data input signal is sampled on the leading clock edge 1 the SPI data input signal is sampled on the trailing clock edge

Examples

AT+CSPISETCLK =1,0,1 OK

Page 236: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 235

AT+CSPISETCLK? +CSPISETCLK: 1,0,1 OK AT+CSPISETCLK=? +CSPISETCLK: (0-1),(0-1),(0-1) OK

10.2 AT+CSPISETCS SPI chip select setting

Description The command is used to set SPI chip select polarity and mode.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CSPISETCS=? +CSPISETCS: (range of supported <mode>s), (range of suppor

ted <polarity>s) OK

Read Command Responses AT+CSPISETCS? +CSPISETCS: <mode>,<polarity>

OK

Write Command Responses OK AT+CSPISETCS=<mode>,<

polarity> ERROR

Defined values

<mode> 0 the SPI chip select is de-asserted between transfer units

1 the SPI chip select is kept asserted between transfer units <polarity> 0 the SPI chip select is active low

1 the SPI chip select is active high

Examples

AT+CSPISETCS =1,0 OK AT+CSPISETCS? +CSPISETCS: 1,0

Page 237: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 236

OK AT+CSPISETCS =? +CSPISETCS: (0-1),(0-1) OK

10.3 AT+CSPISETF SPI clock frequency setting

Description The command is used to set SPI clock frequency

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CSPISETF=? +CSPISETF: (range of supported <min>s), (range of supported

<max>s),(range of supported <de-assertion time>s) OK

Read Command Responses AT+CSPISETF? +CSPISETF: <min>,<max>,<de-assertion time>

OK

Write Command Responses OK AT+CSPISETF=<min>,<ma

x>,<de-assertion time> ERROR

Defined values

<min> In master mode, set the minimum SPI clock frequency by the slave device

0…26000000 <max> In master mode, set the maximum SPI clock frequency by the slave device

0…26000000 <de-assertion time> In master mode, set the minimum time to wait between transfer units in nanoseconds 0…64

Examples

AT+CSPISETF =960000,10000000,0 OK AT+CSPISETF?

Page 238: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 237

+CSPISETF: 960000,10000000,0 OK AT+CSPISETF =? +CSPISETF: (0-26000000), (0-26000000),(0-64) OK

10.4 AT+CSPISETPARA SPI transfer parameters setting

Description The command is used to set SPI transfer parameters

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CSPISETPARA=? +CSPISETPARA: (range of supported <bit>s), (range of suppo

rted <input packed>s),(range of supported <output unpacked>s)OK

Read Command Responses AT+CSPISETPARA? +CSPISETPARA: <bit>,<input packed>,<output unpacked>

OK

Write Command Responses OK AT+CSPISETPARA=<bit>,

<input packed>,<output unpacked>

ERROR

Defined values

<bit> set the number of bits to use per transfer unit, only support 8,16,32 bits

0…32 <input packed>

0 data should be not packed into the user input buffer 1 data should be packed into the user input buffer

<output unpacked> 0 data should be not packed from the user output buffer

1 data should be packed from the user output buffer

Examples

AT+CSPISETPARA =16,0,1

Page 239: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 238

OK AT+CSPISETPARA? +CSPISETPARA:16,0,1 OK AT CSPISETPARA=? +CSPISETPARA : (0-32), (0-1),(0-1) OK

10.5 AT+CSPIW Write data to SPI

Description The command is used to write data to SPI. NOTE If you want to write data only when you use SPI to connect to some special slave device, you can set <reg> to 0xFFFF. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CSPIW=? OK

Write Command Responses OK AT+CSPIW=<reg>,<data>,<

len> ERROR

Defined values

<reg> Register address. Input format must be hex, such as 0xFF.

<data> Data written. Input format must be hex, such as 0xFF – 0xFFFFFFFF.

<len> Read length.The unit is byte 1…4

Examples

AT+CSPIW=0x0F, 0x1234, 2 OK

Page 240: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 239

10.6 AT+CSPIR Read data from SPI

Description The command is used to read data from SPI. NOTE If you want to read data only when you use SPI to connect to some special slave device, you can set <reg> to 0xFFFF. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CSPIR=? OK

Write Command Responses +CSPIR: <data> OK

AT+CSPIR=<reg>,<len>

ERROR

Defined values

<reg> Register address. Input format must be hex, such as 0xFF.

<data> Data read. Input format must be hex, such as 0xFF – 0xFFFFFFFF.

<len> Read length.The unit is byte. 1…4

Examples

AT+CSPIR =0x0F, 2 +CSPIR : 0x1234 OK

Page 241: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 240

11 Phonebook Related Commands

11.1 AT+CNUM Subscriber number

Description Execution command returns the MSISDNs related to the subscriber (this information can be stored in the SIM or in the ME). If subscriber has different MSISDN for different services, each MSISDN is returned in a separate line.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CNUM=? OK

Execution Command Responses [+CNUM: <alpha>,<number>,<type>[<CR><LF> +CNUM: <alpha>, <number>,<type> [...]]] OK

AT+CNUM

+CME ERROR: <err>

Defined values

<alpha> Optional alphanumeric string associated with <number>,used character set should be the one selected with command Select TE Character Set AT+CSCS. <number> String type phone number of format specified by <type>. <type> Type of address octet in integer format.see also AT+CPBR <type>

Examples

AT+CNUM +CNUM: ,"13697252277",129 OK

Page 242: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 241

11.2 AT+CPBS Select phonebook memory storage

Description The command selects the active phonebook storage,i.e.the phonebook storage that all subsequent phonebook commands will be operating on.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CPBS=? +CPBS: (list of supported <storage>s)

OK

Read Command Responses

+CPBS: <storage>[,<used>,<total>]]

OK

AT+CPBS?

+CME ERROR: <err>

Write Command Responses OK

ERROR

AT+CPBS=<storage>

+CME ERROR: <err>

Execution Command Responses

AT+CPBS Set default value “SM”: OK

Defined values

<storage> Values reserved by the present document:

"DC" ME dialed calls list Capacity: max. 10 entries AT+CPBW command is not applicable to this storage. "MC" ME missed (unanswered received) calls list Capacity: max. 10 entries AT+CPBW command is not applicable to this storage. "RC" ME received calls list Capacity: max. 10 entries AT+CPBW command is not applicable to this storage. "SM" SIM phonebook

Page 243: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 242

Capacity: depending on SIM card "ME" Mobile Equipment phonebook Capacity: max. 100 entries "FD" SIM fixdialling-phonebook

Capacity: depending on SIM card "ON" MSISDN list Capacity: depending on SIM card "LD" Last number dialed phonebook Capacity: depending on SIM card AT+CPBW command is not applicable to this storage. "EN" Emergency numbers Capacity: max. 50 entries AT+CPBW command is not applicable to this storage.

<used> Integer type value indicating the number of used locations in selected memory. <total> Integer type value indicating the total number of locations in selected memory.

Examples

AT+CPBS=? +CPBS: ("SM","DC","FD","LD","MC","ME","RC","EN","ON") OK AT+CPBS=”SM” OK AT+CPBS? +CPBS: "SM",1,200 OK

11.3 AT+CPBR Read phonebook entries

Description The command gets the record information from the selected memory storage in phonebook. if the storage is selected as “SM” then the command will return the record in SIM phonebook, the same to others.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CPBR=? +CPBR: (<minIndex>-<maxIndex>), [<nlength>], [<tlength>]

Page 244: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 243

OK

+CME ERROR: <err>

Write Command Responses

[+CPBR: <index1>,<number>,<type>,<text>[<CR><LF>

+CPBR: <index2>,<number>,<type>,<text>[…]]]

OK

ERROR

AT+CPBR= <index1>[,<index2>]

+CME ERROR: <err>

Defined values

<index1> Integer type value in the range of location numbers of phonebook memory. <index2> Integer type value in the range of location numbers of phonebook memory. <index> Integer type.the current position number of the Phonebook index. <minIndex> Integer type the minimum <index> number. <maxIndex> Integer type the maximum <index> number <number> String type, phone number of format <type>, the maximum length is <nlength>. <type> Type of phone number octet in integer format, default 145 when dialing string includes international access code character "+", otherwise 129. <text> String type field of maximum length <tlength>; often this value is set as name. <nlength> Integer type value indicating the maximum length of field <number>. <tlength> Integer type value indicating the maximum length of field <text>.

Examples

AT+CPBS? +CPBS: "SM",2,200 OK AT+CPBR=1,10 +CPBR: 1,"1234567890",129,"James" +CPBR: 2,"0987654321",129,"Kevin" OK

Page 245: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 244

11.4 AT+CPBF Find phonebook entries

Description The command finds the record in phonebook(from the current phonebook memory storage selected with AT+CPBS) which alphanumeric field has substring <findtext>.If <findtext> is null, it will lists all the entries. SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses

+CPBF: [<nlength>],[<tlength>]

OK

AT+CPBF=?

+CME ERROR: <err>

Write Command Responses

[+CPBF: <index1>,<number>,<type>,<text>[<CR><LF>

+CBPF: <indexN>,<number>,<type>,<text>[…]]]

OK

ERROR

AT+CPBF=[<findtext>]

+CME ERROR: <err>

Defined values

<findtext> String type, this value is used to find the record. Character set should be the one selected with command AT+CSCS. <index> Integer type values in the range of location numbers of phonebook memory. <number> String type, phone number of format <type>, the maximum length is <nlength>. <type> Type of phone number octet in integer format, default 145 when dialing string includes international access code character "+", otherwise 129. <text> String type field of maximum length <tlength>; Often this value is set as name. <nlength> Integer type value indicating the maximum length of field <number>. <tlength> Integer type value indicating the maximum length of field <text>.

Page 246: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 245

Examples

AT+CPBF=" James " +CPBF: 1,"1234567890",129," James " OK

11.5 AT+CPBW Write phonebook entry

Description The command writes phonebook entry in location number <index> in the current phonebook memory storage selected with AT+CPBS.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses

+CPBW:(list of supported <index>s),[<nlength>],

(list of supported <type>s),[<tlength>]

OK

AT+CPBW=?

+CME ERROR:<err>

Write Command Responses OK

ERROR

AT+CPBW=[<index>][,<number>[,<type>[,<text>]]]

+CME ERROR:<err>

Defined values

<index> Integer type values in the range of location numbers of phonebook memory.If <index> is not given,the first free entry will be used. If <index> is given as the only parameter, the phonebook entry specified by <index> is deleted.If record number <index> already exists, it will be overwritten. <number> String type, phone number of format <type>, the maximum length is <nlength>.It must be an non-empty string. <type> Type of address octet in integer format, If <number> contains a leading “+” <type> = 145 (international) is used.Supported value are:

145 – when dialling string includes international access code character “+” 161 – national number.The network support for this type is optional 177 – network specific number,ISDN format

Page 247: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 246

129 – otherwise <text> String type field of maximum length <tlength>; character set as specified by command Select TE Character Set AT+CSCS. <nlength> Integer type value indicating the maximum length of field <number>. <tlength> Integer type value indicating the maximum length of field <text>. NOTE If the parameters of <type> and <text> are omitted and the first character of <number> is ‘+’,it will specify <type> as 145(129 if the first character isn’t ‘+’) and <text> as NULL.

Examples

AT+CPBW=3,"88888888",129,"John" OK AT+CPBW=,”6666666”,129,”mary” OK AT+CPBW=1 OK

11.6 AT+CEMNLIST Set the list of emergency number

Description The command allows to define emergency numbers list according to customers’ requirement.Note that only no sim card is inserted or sim card is locked, these emergency numbers ta-ke effect. When it is set enable and in the above situation, the customer defined emergency numbers in <emergency numbers> take effect, but the emergency numbers in the “EN” phonebook storage do not take effect. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CEMNLIST=? +CEMNLIST: (list of supported <mode>s), <nlength>,<total>

OK

Read Command Responses AT+CEMNLIST? +CEMNLIST: <mode>,<emergency numbers>

OK

Write Command Responses AT+CEMNLIST=<mode>[, OK

Page 248: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 247

<emergency numbers>]

Defined values

<mode> 0 disable 1. enable 2 edit emergency numbers

<nlength> Integer type value indicating the maximum length of single emergency number. <total> Integer type value indicating the total number of emergency numbers. <emergency numbers> Emergency numbers list, string type. <emergency number> includes all of emergency numbers,every emergency number is seperated by comma,for example “911,112”.

Examples

AT+CEMNLIST=? +CEMNLIST: (0-2),10,30 OK AT+CEMNLIST? +CEMNLIST: 1,”911,112” OK AT+CEMNLIST=1 OK AT+CEMNLIST=2,”911,112” OK

12 File System Related Commands

The file system is used to store files in a hierarchical (tree) structure, and there are some definitions and conventions to use the Module.

Local storage space is mapped to “C:”.

NOTE General rules for naming (both directories and files):

1 The length of actual fully qualified names of directories and files can not exceed 254. 2 Directory and file names can not include the following characters:

\ : * ? “ < > | , ; 3 Between directory name and file/directory name, use character “/” as list separator, so it can not

appear in directory name or file name.

Page 249: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 248

4 The first character of names must be a letter or a numeral or underline, and the last character can not be period “.” and oblique “/”.

12.1 AT+FSCD Select directory as current directory

Description The command is used to select a directory. The Module supports absolute path and relative path. Read Command will return current directory without double quotation marks.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+FSCD=? OK

Read Command Responses AT+FSCD? +FSCD: <curr_path>

OK

Write Command Responses +FSCD: <curr_path> OK

AT+FSCD=<path>

ERROR

Defined values

<path> String without double quotes, directory for selection. NOTE If <path> is “..”, it will go back to previous level of directory. <curr_path> String without double quotes, current directory.

Examples

AT+FSCD=C: +FSCD: C:/ OK AT+FSCD=C:/ +FSCD: C:/ OK AT+FSCD? +FSCD: C:/

Page 250: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 249

OK AT+FSCD=.. +FSCD: C:/ OK

12.2 AT+FSMKDIR Make new directory in current directory

Description The command is used to create a new directory in current directory..

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+FSMKDIR=? OK

Write Command Responses OK AT+FSMKDIR=<dir>

ERROR

Defined values

<dir> String without double quotes, directory name which is not already existing in current directory.

Examples

AT+FSMKDIR= SIMTech OK AT+FSCD? +FSCD: C:/ OK AT+FSLS +FSLS: SUBDIRECTORIES: SIMTech OK

Page 251: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 250

12.3 AT+FSRMDIR Delete directory in current directory

Description The command is used to delete existing directory in current directory.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+FSRMDIR=? OK

Write Command Responses OK AT+FSRMDIR=<dir>

ERROR

Defined values

<dir> String without double quotes, directory name which is relative and already existing.

Examples

AT+FSRMDIR=SIMTech OK AT+FSCD? +FSCD: C:/ OK AT+FSLS +FSLS: SUBDIRECTORIES: Audio Picture Video VideoCall OK

12.4 AT+FSLS List directories/files in current directory

Description The command is used to list informations of directories and/or files in current directory.

Page 252: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 251

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+FSLS=? +FSLS: (list of supported <type>s)

OK

Read Command Responses AT+FSLS? +FSLS: SUBDIRECTORIES: <dir_num>, FILES: <file_num>

OK

Write Command Responses AT+FSLS=<type> [+FSLS: SUBDIRECTORIES:

<list of subdirectories> <CR><LF>] [+FSLS: FILES: <list of files> <CR><LF>] OK

Execution Command Responses AT+FSLS [+FSLS: SUBDIRECTORIES:

<list of subdirectories> <CR><LF>] [+FSLS: FILES: <list of files> <CR><LF>] OK

Defined values

<dir_num> Integer type, the number of subdirectories in current directory. <file_num> Integer type, the number of files in current directory. <type>

0 – list both subdirectories and files 1 – list subdirectories only

2 – list files only

Examples

AT+FSLS?

Page 253: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 252

+FSLS: SUBDIRECTORIES: 2, FILES: 2 OK AT+FSLS +FSLS: SUBDIRECTORIES: FirstDir SecondDir +FSLS: FILES: image_0.jpg image_1.jpg OK AT+FSLS=2 +FSLS: FILES: image_0.jpg image_1.jpg OK

12.5 AT+FSDEL Delete file in current directory

Description The command is used to delete a file in current directory. Before do that, it needs to use AT+FSCD select the father directory as current directory.

SIM PIN References

NO Vendor

Syntax

Test Command Responses

AT+FSDEL=? OK

Write Command Responses OK AT+FSDEL=<filename>

ERROR

Defined values

<filename> String without double quotes, file name which is relative and already existing. If <filename> is *.*, it means delete all files in current directory.

Page 254: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 253

Examples

AT+FSDEL=image_0.jpg OK

12.6 AT+FSRENAME Rename file in current directory

Description The command is used to rename a file in current directory.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+FSRENAME=? OK

Write Command Responses OK AT+FSRENAME=

<old_name>,<new_name> ERROR

Defined values

<old_name> String without double quotes, file name which is existed in current directory. <new_name> New name of specified file, string without double quotes.

Examples

AT+FSRENAME=image_0.jpg, image_1.jpg OK

12.7 AT+FSATTRI Request file attributes

Description The command is used to request the attributes of file which is existing in current directory.

SIM PIN References

NO Vendor

Syntax

Page 255: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 254

Test Command Responses

AT+FSATTRI=? OK

Write Command Responses AT+FSATTRI=<filename> +FSATTRI: <file_size>, <create_date>

OK

Defined values

<filename> String without double quotes, file name which is in current directory. <file_size> The size of specified file, and the unit is in Byte. <create_date> Create date and time of specified file, the format is YYYY/MM/DD HH/MM/SS Week.

Week – Mon, Tue, Wed, Thu, Fri, Sat, Sun

Examples

AT+FSATTRI=image_0.jpg +FSATTRI: 8604, 2008/04/28 10:24:46 Tue OK

12.8 AT+FSMEM Check the size of available memory

Description The command is used to check the size of available memory. The response will list total size and used size of local storage space if present and mounted. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+FSMEM=? OK

Execution Command Responses AT+FSMEM +FSMEM: C:(<total>, <used>)

OK

Defined values

<total>

Page 256: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 255

The total size of local storage space. <used> The used size of local storage space. NOTE 1.The unit of storage space size is in Byte.

Examples

AT+FSMEM +FSMEM: C:(11348480, 2201600) OK

12.9 AT+FSLOCA Select storage place

Description The command is used to set the storage place for media files.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+FSLOCA=? +FSLOCA: (list of supported <loca>s)

OK

Read Command Responses AT+FSLOCA? +FSLOCA: <loca>

OK

Write Command Responses OK AT+FSLOCA=<loca>

ERROR

Defined values

<loca> 0 – store media files to local storage space (namely “C:/”)

Examples

AT+FSLOCA=0 OK AT+FSLOCA? +FSLOCA: 0

Page 257: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 256

OK

12.10 AT+FSCOPY Copy an appointed file

Description The command is used to copy an appointed file on C:/ to an appointed directory on C:/, the new file name should give in parameter. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+FSCOPY=? OK

Write Command Responses +FSCOPY: <percent> [+FSCOPY: <percent>] OK

AT+FSCOPY=<file1>,<file2>

If found any error: SD CARD NOT PLUGGED IN FILE IS EXISTING FILE NOT EXISTING DIRECTORY IS EXISTED DIRECTORY NOT EXISTED FORBID CREATE DIRECTORY UNDER \"C:/\" FORBID DELETE DIRECTORY INVALID PATH NAME INVALID FILE NAME SD CARD HAVE NO ENOUGH MEMORY EFS HAVE NO ENOUGH MEMORY FILE CREATE ERROR READ FILE ERROR WRITE FILE ERROR ERROR

Defined values

<file1> The sources file name or the whole path name with sources file name. <file2> The destination file name or the whole path name with destination file name. <percent>

Page 258: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 257

The percent of copy done. The range is 0.0 to 100.0 NOTE

1. The <file1> and <file2> should give the whole path and name, if only given file name, it will refer to current path (AT+FSCD) and check the file’s validity. 2. If <file2> is a whole path and name, make sure the directory exists, make sure that the file name does not exist or the file name is not the same name as the sub folder name, otherwise return error. 3. <percent> report refer to the copy file size. The big file maybe report many times, and little file report less.

Examples

AT+FSCD? +FSCD: C:/ OK AT+FSCOPY= C:/TESTFILE,COPYFILE (Copy file TESTFILE on C:/ to C:/COPYFILE) +FSCOPY: 1.0 +FSCOPY: 9.7 +FSCOPY: 19.4 … +FSCOPY: 100.0 OK

Page 259: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 258

13 File Transmission Related Commands

The module supports file transmission between the Module and PC host over Xmodem protocol, and the transmission is bidirectional.

13.1 AT+CTXFILE Select file transmitted to PC host

Description The command is used to select a file which is transmitted from the module to PC host. After selecting the file successfully, use HyperTerminal to get the file over Xmodem protocol [refer AT Commands Samples: File transmission to PC host]. If available memory is not enough, file transmission will fail. Note: If available memory is not enough, file transmission will fail. If you use HyperTerminal Applet (MS), please to make sure the storage path to PC host can not include Chinese character, but file name can include Chinese character. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CTXFILE=? +CTXFILE: (list of supported <dir_type>s), (list of supported

<protocol>s) OK

Write Command Responses OK AT+CTXFILE=<file_name>

[,<dir_type>[,<protocol>]] FILE NOT EXISTING ERROR

Defined values

<filename> String with double quotes, file name to be transmitted to PC host which already exists.

NOTE The path to where you want to save the file by using HyperTerminal, must not contain any Chinese character. <dir_type>

0 – file to be transmitted is in current directory; before AT+CTXFILE execution, it needs to set current directory [refer AT+FSCD] NOTE If <dir_type> is omitted, it will select a file to be transmitted which is in current directory.

Page 260: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 259

AT+FSCD and AT+FSLS being used in combination can help user to check the file selected whether existing or not. <protocol>

0 – Xmodem 1 – 1K Xmodem

Examples

AT+CTXFILE=”image_0.jpg”, 0,1 OK …… AT+FSCD=C:/ +FSCD: C:/ OK AT+FSLS video_0.mp4 video_1.mp4 OK AT+CTXFILE=”video_2.mp4” OK ….

13.2 AT+CRXFILE Set name of file received from PC host

Description The command is used to set file name which is received from PC host to file system of module. After setting successfully, use HyperTerminal to send the file over Xmodem protocol [refer AT Commands Samples: File received from PC host].

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CRXFILE=? +CRXFILE: (list of supported <dir_type>s)

OK

Write Command Responses OK AT+CRXFILE=<file_name>

[,<dir_type>] FILE IS EXISTING ERROR

Defined values

Page 261: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 260

<file_name> String with double quotes, file name which is received from PC host. <dir_type> Specify storage location of file which is received from PC host. If this parameter is omitted, it will save the file to current directory [refer AT+FSCD]

0 – save file received from PC host to current directory; before AT+CTXFILE execution, it needs to set current directory [refer AT+FSCD]

Examples

AT+CRXFILE=”image_8.jpg”,0 OK …… AT+FSCD=C:/ +FSCD: C:/ OK AT+CRXFILE=”video.mp4” OK ….

13.3 AT+CMWAIT config the waiting seconds before xmodem start

receiving

Description This command is used to config the waiting seconds when setup a xmodem receiving task. Set to zero means no wait and start receive process. Ought to be used together with +CRXFILE command.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CMWAIT=? +CMWAIT: (0-60)

OK

Read Command Responses +CMWAIT: <value> OK

AT+CMWAIT?

ERROR

Write Command Responses

Page 262: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 261

OK AT+CMWAIT=<value>

ERROR

Execution Command Responses AT+CMWAIT +CMWAIT: 10

OK

Defined values

< value >: 0 – 60 second

Examples

+FSCD=C:/Video +FSCD: C:/Video/ OK AT+CMWAIT=5 OK AT+CRXFILE=”1.txt” OK …

NOTE: 1. The default < value > is 10 second, it can be set to any positive integer value, 0~60 is permitted.. 2. The < value > cann’t be saved, will be set to default value when the device restart later.

Page 263: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 262

14 V24-V25 Commands

14.1 AT+IPR Set local baud rate temporarily

Description The command sets the baud rate of module’s serial interface temporarily, after reboot the baud rate is set to default value.The default value is 115200.

SIM PIN References

NO V.25ter

Syntax

Test Command Responses AT+IPR=? +IPR: (list of supported<speed>s)

OK

Read Command Responses AT+IPR? +IPR: <speed>

OK

Write Command Responses OK AT+IPR=<speed>

ERROR Execution Command Responses AT+IPR Set default value 115200:

OK

Defined values

<speed> Baud rate per second:

300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 460800,921600, 3200000,3686400,4000000

Examples

AT+IPR? +IPR: 115200 OK AT+IPR=?

Page 264: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 263

+IPR:(300,600,1200,2400,4800,9600,19200,38400,57600,115200,230400,460800,921600, 3200000, 3686400, 4000000) OK AT+IPR=115200 OK

14.2 AT+IPREX Set local baud rate permanently

Description The command sets the baud rate of module’s serial interface permanently, after reboot the baud rate is also valid.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+IPREX=? +IPREX: (list of supported<speed>s)

OK

Read Command Responses AT+IPREX? +IPREX: <speed>

OK

Write Command Responses OK AT+IPREX =<speed>

ERROR Execution Command Responses AT+IPREX Set default value 115200:

OK

Defined values

<speed> Baud rate per second:

300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 460800,921600, 3200000,3686400,4000000

Examples

AT+IPREX? +IPREX: 115200 OK

Page 265: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 264

AT+IPREX=? +IPREX: (300,600,1200,2400,4800,9600,19200,38400,57600,115200,230400,460800,921600 3200000, 3686400, 4000000) OK AT+IPREX=115200 OK

14.3 AT+ICF Set control character framing

Description The command sets character framing which contain data bit, stop bit and parity bit.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+ICF=? +ICF: (list of supported<format>s), (list of supported<parity>s)

OK

Read Command Responses AT+ICF? +ICF: <format>,<parity>

OK

Write Command Responses OK AT+ICF=

<format>[,<parity>] ERROR Execution Command Responses AT+ICF Set default value:

OK

Defined values

<format> Only support value “3” at moment:

3 – data bit 8, stop bit 1 <parity>

0 – Odd 1 – Even 2 – mark 3 – none

Examples

Page 266: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 265

AT+ICF? +ICF: 3,3 OK AT+ICF=? +ICF: (3),(0-3) OK AT+ICF=3,3 OK

14.4 AT+IFC Set local data flow control

Description The command sets the flow control of the module.

SIM PIN References

NO V.25ter

Syntax

Test Command Responses AT+IFC=? +IFC: (list of supported<DCE>s), (list of supported<DTE>s)

OK

Read Command Responses AT+IFC? +IFC: <DCE>,<DTE>

OK

Write Command Responses OK AT+IFC=<DCE>[,<DTE>]

ERROR Execution Command Responses AT+IFC Set default value:

OK

Defined values

<DCE> 0 – none (default) 2 – RTS hardware flow control

<DTE> 0 – none (default) 2 – CTS hardware flow control

Examples

Page 267: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 266

AT+IFC? +IFC: 0,0 OK AT+IFC=? +IFC: (0,2),(0,2) OK AT+IFC=2,2 OK

14.5 AT&C Set DCD function mode

Description The command determines how the state of circuit 109 (DCD) relates to the detection of received line signal from the distant end. NOTE After executing AT+CSUART=1 and AT+CDCDMD=0,it takes effect. SIM PIN References

NO V.25ter

Syntax

Execution Command Responses OK AT&C[<value>]

ERROR

Defined values

<value> 0 DCD line shall always be on. 1 DCD line shall be on only when data carrier signal is present. 2 Setting winks(briefly transitions off,then back on)the DCD line when data calls end.

Examples

AT&C1 OK

14.6 ATE Enable command echo

Description The command sets whether or not the TA echoes characters.

SIM PIN References

Page 268: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 267

NO V.25ter

Syntax

Execution Command Responses OK ATE[<value>]

ERROR

Defined values

<value> 0 – Echo mode off 1 – Echo mode on

Examples

ATE1 OK

14.7 AT&V Display current configuration

Description The command returns some of the base configuration parameters settings.

SIM PIN References

YES V.25ter

Syntax

Execution Command Responses AT&V <TEXT>

OK

Defined values

<TEXT> All relative configuration information.

Examples

AT&V &C: 0; &D: 2; &F: 0; E: 1; L: 0; M: 0; Q: 0; V: 1; X: 0; Z: 0; S0: 0; S3: 13; S4: 10; S5: 8; S6: 2; S7: 50; S8: 2; S9: 6; S10: 14; S11: 95;

Page 269: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 268

+FCLASS: 0; +ICF: 3,3; +IFC: 2,2; +IPR: 115200; +DR: 0; +DS: 0,0,2048,6; +WS46: 12; +CBST: 0,0,1; …… OK

14.8 AT&D Set DTR function mode

Description The command determines how the TA responds when circuit 108/2 (DTR) is changed fromthe ON to the OFF condition during data mode. NOTE After executing AT+CSUART=1,it takes effect. SIM PIN References

NO V.25ter

Syntax

Execution Command Responses OK AT&D[<value>]

ERROR

Defined values

<value> 0 TA ignores status on DTR. 1 ON->OFF on DTR: Change to Command mode with remaining the connected call 2 ON->OFF on DTR: Disconnect call, change to Command mode.During state DTR =

OFF is auto-answer off.

Examples

AT&D1 OK

14.9 AT&S Set DSR function mode

Description The command determines how the state of DSR pin works.

SIM PIN References

NO V.25ter

Syntax

Page 270: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 269

Execution Command Responses OK AT&S[<value>]

ERROR

Defined values

<value> 0 DSR line shall always be on. 1 DSR line shall be on only when DTE and DCE are connected.

Examples

AT&S0 OK

14.10 ATV Set result code format mode

Description This parameter setting determines the contents of the header and trailer transmitted with result codes and information responses. NOTE: In case of using the command without parameter <value> will be set to 0. SIM PIN References

NO V.25ter

Syntax

Write Command Responses ATV[<value>] If <value> =0

0 If <value> =1 OK

Defined values

<value> 0 Information response: <text><CR><LF>

Short result code format: <numeric code><CR> 1 Information response: <CR><LF><text><CR><LF>

Long result code format: <CR><LF><verbose code><CR><LF>

Examples

ATV1

Page 271: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 270

OK

Page 272: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 271

15 Commands for Packet Domain

15.1 AT+CGDCONT Define PDP context

Description The set command specifies PDP context parameter values for a PDP context identified by the (local) context identification parameter <cid>. The number of PDP contexts that may be in a defined state at the same time is given by the range returned by the test command. A special form of the write command (AT+CGDCONT=<cid>) causes the values for context <cid> to become undefined. SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses +CGDCONT: (range of supported<cid>s),<PDP_type>,,,(list of supported <d_comp>s),(list of supported <h_comp>s) OK

AT+CGDCONT=?

ERROR

Read Command Responses +CGDCONT: [<cid>, <PDP_type>, <APN>,<PDP_addr>, <d_comp>, <h_comp>[<CR><LF> +CGDCONT: <cid>, <PDP_type>, <APN>, <PDP_addr>, <d_comp>, <h_comp>[...]]] OK

AT+CGDCONT?

ERROR

Write Command Responses OK AT+CGDCONT=

<cid>[,<PDP_type> [,<APN>[,<PDP_addr> [,<d_comp>[,<h_comp>]]]]]

ERROR

Execution Command Responses OK AT+CGDCONT

ERROR

Defined values

Page 273: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 272

<cid> (PDP Context Identifier) a numeric parameter which specifies a particular PDP context definition. The parameter is local to the TE-MT interface and is used in other PDP context-related commands. The range of permitted values (minimum value = 1) is returned by the test form of the command.

1…16 <PDP_type> (Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.

IP Internet Protocol PPP Point to Point Protocol IPV6 Internet Protocol Version 6

<APN> (Access Point Name) a string parameter which is a logical name that is used to select the GGSN or the external packet data network. <PDP_addr> A string parameter that identifies the MT in the address space applicable to the PDP. Read command will continue to return the null string even if an address has been allocated during the PDP startup procedure. The allocated address may be read using command AT+CGPADDR. <d_comp> A numeric parameter that controls PDP data compression, this value may depend on platform:

0 – off (default if value is omitted) 1 – on 2 – V.42bis

<h_comp> A numeric parameter that controls PDP header compression, this value may depend on platform:

0 – off (default if value is omitted) 1 – on 2 – RFC1144 3 – RFC2507 4 – RFC3095

Examples

AT+CGDCONT? +CGDCONT: 1,"IP","","0.0.0.0",0,0 OK AT+CGDCONT=? +CGDCONT: (1-16),"IP",,,(0-2),(0-4) +CGDCONT: (1-16),"PPP",,,(0-2),(0-4) +CGDCONT: (1-16),"IPV6",,,(0-2),(0-4) OK

Page 274: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 273

15.2 AT+CGDSCONT Define Secondary PDP Context

Description The set command specifies PDP context parameter values for a Secondary PDP context identified by the (local) context identification parameter, <cid>. The number of PDP contexts that may be in a defined state at the same time is given by the range returned by the test command. A special form of the set command, AT+CGDSCONT=<cid> causes the values for context number <cid> to become undefined. SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CGDSCONT=? +CGDSCONT: (range of supported <cid>s),(list of <p_cid>s for

active primary contexts),(list of supported <d_comp>s),(list of supported <h_comp>s) OK

Read Command Responses AT+CGDSCONT? +CGDSCONT: <cid>,<p_cid>,<d_comp>,<h_comp>

[<CR><LF>+CGDSCONT: <cid>,<p_cid>,<d_comp>,<h_comp>[...]] OK

Write Command Responses OK AT

+CGDSCONT=<cid>[,<p_cid>[,<d_comp>[,<h_comp>]]]

ERROR

Defined values

<cid> a numeric parameter which specifies a particular PDP context definition. The parameter is local to the TE-MT interface and is used in other PDP context-related commands. The range of permitted values (minimum value = 1) is returned by the test form of the command. NOTE: The <cid>s for network-initiated PDP contexts will have values outside the ranges indicated for the <cid> in the test form of the commands +CGDCONT and +CGDSCONT. <p_cid>

Page 275: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 274

a numeric parameter which specifies a particular PDP context definition which has been specified by use of the +CGDCONT command. The parameter is local to the TE-MT interface. The list of permitted values is returned by the test form of the command. <d_comp> a numeric parameter that controls PDP data compression (applicable for SNDCPonly) (refer 3GPP TS 44.065 [61])

0 off 1 on (manufacturer preferred compression) 2 V.42bis 3 V.44 Other values are reserved.

<h_comp> a numeric parameter that controls PDP header compression (refer 3GPP TS 44.065 [61] and 3GPP TS 25.323 [62])

0 off 1 on (manufacturer preferred compression) 2 RFC1144 (applicable for SNDCP only) 3 RFC2507 4 RFC3095 (applicable for PDCP only) Other values are reserved.

Examples

AT+CGDSCONT? +CGDSCONT: 2,1,0,0 OK AT+CGDSCONT=2,1 OK AT+CGDSCONT=? +CGDSCONT: (1-16),(1),"IP",,,(0-2),(0-4) +CGDSCONT: (1-16),(1),"PPP",,,(0-2),(0-4) +CGDSCONT: (1-16),(1),"IPV6",,,(0-2),(0-4) OK

15.3 AT+CGTFT Define Secondary PDP Context

Description This command allows the TE to specify a Packet Filter - PF for a Traffic Flow Template - TFT that is used in the GGSN in UMTS/GPRS and Packet GW in EPS for routing of packets onto different QoS flows towards the TE. The concept is further described in the 3GPP TS 23.060 [47]. A TFT

Page 276: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 275

consists of from one and up to 16 Packet Filters, each identified by a unique <packet filter identifier>. A Packet Filter also has an <evaluation precedence index> that is unique within all TFTs associated with all PDP contexts that are associated with the same PDP address. SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CGTFT=? +CGTFT: <PDP_type>,(list of supported <packet filter

identifier>s),(list of supported <evaluation precedence index>s),(list of supported <source address and subnet mask>s),(list of supported <protocol number (ipv4) / next header (ipv6)>s),(list of supported <destination port range>s),(list of supported <source port range>s),(list of supported <ipsec security parameter index (spi)>s),(list of supported <type of service (tos) (ipv4) and mask / traffic class (ipv6) and mask>s),(list of supported <flow label (ipv6)>s),(list of supported <direction>s) [<CR><LF>+CGTFT: <PDP_type>,(list of supported <packet filter identifier>s),(list of supported <evaluation precedence index>s),(list of supported <source address and subnet mask>s),(list of supported <protocol number (ipv4) / next header (ipv6)>s),(list of supported <destination port range>s),(list of supported <source port range>s),(list of supported <ipsec security parameter index (spi)>s),(list of supported <type of service (tos) (ipv4) and mask / traffic class (ipv6) and mask>s),(list of supported <flow label (ipv6)>s),(list of supported <direction>s) [...]] OK

Read Command Responses AT+CGTFT? +CGTFT: <cid>,<packet filter identifier>,<evaluation precedence

index>,<source address and subnet mask>,<protocol number (ipv4) / next header (ipv6)>,<destination port range>,<source port range>,<ipsec security parameter index (spi)>,<type of service (tos) (ipv4) and mask / traffic class (ipv6) and mask>,<flow label (ipv6)>,<direction> [<CR><LF>+CGTFT: <cid>,<packet filter identifier>,<evaluation precedence index>,<source address and subnet mask>,<protocol number (ipv4) / next header (ipv6)>,<destination port range>,<source port range>,<ipsec security parameter index (spi)>,<type of service (tos) (ipv4) and mask / traffic class (ipv6)

Page 277: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 276

and mask>,<flow label (ipv6)>,<direction> [...]] OK

Write Command Responses OK +CGTFT=<cid>[,[<packet

filter identifier>,<evaluation precedence index>[,<source address and subnet mask>[,<protocol number (ipv4) / next header (ipv6)>[,<destination port range>[,<source port range>[,<ipsec security parameter index (spi)>[,<type of service (tos) (ipv4) and mask / traffic class (ipv6) and mask>[,<flow label (ipv6)>[,<direction>]]]]]]]]]]

ERROR

Defined values

<cid> a numeric parameter which specifies a particular PDP context definition (see the +CGDCONT and +CGDSCONT commands). <packet filter identifier> a numeric parameter, value range from 1 to 16. <evaluation precedence index> a numeric parameter. The value range is from 0 to 255. <source address and subnet mask> string type. The string is given as dot-separated numeric (0-255) parameters on the form: "a1.a2.a3.a4.m1.m2.m3.m4" for IPv4 or "a1.a2.a3.a4.a5.a6.a7.a8.a9.a10.a11.a12.a13.a14.a15.a16.m1.m2.m3.m4.m5.m6.m7.m8.m9.m10.m11.m12.m13.m14.m15.m16", for IPv6. <protocol number (ipv4) / next header (ipv6)> a numeric parameter, value range from 0 to 255. <destination port range> string type. The string is given as dot-separated numeric (0-65535) parameters on the form "f.t". <source port range> string type. The string is given as dot-separated numeric (0-65535) parameters on the form "f.t". <ipsec security parameter index (spi)> numeric value in hexadecimal format. The value range is from 00000000 to FFFFFFFF.

Page 278: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 277

<type of service (tos) (ipv4) and mask / traffic class (ipv6) and mask>

string type. The string is given as dot-separated numeric (0-255) parameters on the form "t.m". <flow label (ipv6)> numeric value in hexadecimal format. The value range is from 00000 to FFFFF. Valid for IPv6 only.<direction> a numeric parameter which specifies the transmission direction in which the packet filter shall be applied.

0 Pre-Release 7 TFT filter (see 3GPP TS 24.008 [8], table 10.5.162) 1 Uplink 2 Downlink 3 Birectional (Up & Downlink)

Examples

AT+CGTFT? +CGTFT: 2,1,0,"74.125.71.99.255.255.255.255",0,0.0,0.0,0,0.0,0 OK AT+CGTFT=2,1,0,"74.125.71.99.255.255.255.255" OK AT+CGTFT=? +CGTFT: "IP",(1-2),(0-255),,(0-255),(0-65535.0-65535),(0-65535.0-65535),(0-FFFFF FFF),(0-255.0-255),(0-FFFFF) +CGTFT: "PPP",(1-2),(0-255),,(0-255),(0-65535.0-65535),(0-65535.0-65535),(0-FFFF FFFF),(0-255.0-255),(0-FFFFF) +CGTFT: "IPV6",(1-2),(0-255),,(0-255),(0-65535.0-65535),(0-65535.0-65535),(0-FFF FFFFF),(0-255.0-255),(0-FFFFF) OK

15.4 AT+CGQREQ Quality of service profile (requested)

Description The command allows the TE to specify a Quality of Service Profile that is used when the MT sends an Activate PDP Context Request message to the network.. A special form of the set command (AT+CGQREQ=<cid>) causes the requested profile for context number <cid> to become undefined. SIM PIN References

YES 3GPP TS 27.007

Syntax

Page 279: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 278

Test Command Responses +CGQREQ: <PDP_type>, (list of supported <precedence>s), (list of supported <delay>s), (list of supported <reliability>s) , (list of supported <peak>s), (list of supported <mean>s) [<CR><LF> +CGQREQ: <PDP_type>, (list of supported <precedence>s), (list of supported <delay>s), (list of supported <reliability>s) , (list of supported <peak>s), (list of supported <mean>s) […]] OK

AT+CGQREQ=?

ERROR

Read Command Responses +CGQREQ: [<cid>, <precedence >, <delay>, <reliability>, <peak>, <mean>[<CR><LF> +CGQREQ: <cid>, <precedence >, <delay>, <reliability.>, <peak>, <mean>[…]]] OK

AT+CGQREQ?

ERROR

Write Command Responses OK AT+CGQREQ=<cid>

[,<precedence> [,<delay>[,<reliability> [,<peak> [,<mean>]]]]]

ERROR

Execution Command Responses

OK AT+CGQREQ

ERROR

Defined values

<cid> A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT command).

1…16 <PDP_type> (Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.

IP Internet Protocol PPP Point to Point Protocol IPV6 Internet Protocol Version 6

<precedence> A numeric parameter which specifies the precedence class:

0 – network subscribed value 1 – high priority

Page 280: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 279

2 – normal priority 3 – low priority

<delay> A numeric parameter which specifies the delay class:

0 – network subscribed value 1 – delay class 1 2 – delay class 2 3 – delay class 3 4 – delay class 4

<reliability> A numeric parameter which specifies the reliability class:

0 – network subscribed value 1 – Non real-time traffic,error-sensitive application that cannot cope with data loss 2 – Non real-time traffic,error-sensitive application that can cope with infrequent data loss 3 – Non real-time traffic,error-sensitive application that can cope with data loss, GMM/-

SM,and SMS 4 – Real-time traffic,error-sensitive application that can cope with data loss 5 – Real-time traffic error non-sensitive application that can cope with data loss

<peak> A numeric parameter which specifies the peak throughput class:

0 – network subscribed value 1 – Up to 1000 (8 kbit/s) 2 – Up to 2000 (16 kbit/s) 3 – Up to 4000 (32 kbit/s) 4 – Up to 8000 (64 kbit/s) 5 – Up to 16000 (128 kbit/s) 6 – Up to 32000 (256 kbit/s) 7 – Up to 64000 (512 kbit/s) 8 – Up to 128000 (1024 kbit/s) 9 – Up to 256000 (2048 kbit/s)

<mean> A numeric parameter which specifies the mean throughput class:

0 – network subscribed value 1 – 100 (~0.22 bit/s) 2 – 200 (~0.44 bit/s) 3 – 500 (~1.11 bit/s) 4 – 1000 (~2.2 bit/s) 5 – 2000 (~4.4 bit/s) 6 – 5000 (~11.1 bit/s) 7 – 10000 (~22 bit/s) 8 – 20000 (~44 bit/s) 9 – 50000 (~111 bit/s) 10 – 100000 (~0.22 kbit/s)

Page 281: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 280

11 – 200000 (~0.44 kbit/s) 12 – 500000 (~1.11 kbit/s) 13 – 1000000 (~2.2 kbit/s) 14 – 2000000 (~4.4 kbit/s) 15 – 5000000 (~11.1 kbit/s) 16 – 10000000 (~22 kbit/s) 17 – 20000000 (~44 kbit/s) 18 – 50000000 (~111 kbit/s) 31 – optimization

Examples

AT+CGQREQ? +CGQREQ: OK AT+CGQREQ=? +CGQREQ: "IP",(0-3),(0-4),(0-5),(0-9),(0-18,31) +CGQREQ: "PPP",(0-3),(0-4),(0-5),(0-9),(0-18,31) +CGQREQ: "IPV6",(0-3),(0-4),(0-5),(0-9),(0-18,31) OK

15.5 AT+CGEQREQ 3G quality of service profile (requested)

Description The test command returns values supported as a compound value. The read command returns the current settings for each defined context for which a QOS was explicitly specified. The write command allows the TE to specify a Quality of Service Profile for the context identified by the context identification parameter <cid> which is used when the MT sends an Activate PDP Context Request message to the network. A special form of the write command,AT+CGEQREQ=<cid> causes the requested profile for context number <cid> to become undefined. SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses

Page 282: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 281

AT+CGEQREQ=? +CGEQREQ: <PDP_type>,(list of supported <Traffic class>s),(list of supported <Maximum bitrate UL>s),(list of supported <Maxim um bitrate DL>s),(list of supported <Guaranteed bitrate UL>s,(list of supported <Guaranteed bitrate DL>s),(list of supported <Deliv ery order>s),(list of supported <Maximum SDU size>s),(list of supported <SDU error ratio>s),(list of supported <Residual bit errorRatio>s),(list of supported <Delivery of erroneous SDUs>s),(list of Supported <Transfer delay>s),(list of supported <Traffic handling priority>s) OK

Read Command Responses AT+CGEQREQ? +CGEQREQ: [<cid>,<Traffic class>,<Maximum bitrate UL>,<Ma

ximum bitrate DL>,<Guaranteed bitrate UL>,<Guaranteed bitrate DL>,<Delivery order>,<Maximum SDU size>,<SDU error ratio>, <Residual bit error ratio>,<Delivery of erroneous SDUs>,<TransferDelay>,<Traffic handling priority>][<CR><LF> +CGEQREQ: <cid>,<Traffic class>,<Maximum bitrate UL>,<Ma ximum bitrate DL>,<Guaranteed bitrate UL>,<Guaranteed bitrate DL>,<Delivery order>,<Maximum SDU size>,<SDU error ratio>, <Residual bit error ratio>,<Delivery of erroneous SDUs>,<TransferDelay>,<Traffic handling priority>[…]] OK

Write Command Responses OK

ERROR

AT+CGEQREQ=<cid>[,<Traffic class>[,<Maximum bitrate UL>[,<Maximum bitrate DL>[,<Guaranteed bitrateUL>[,<Guaranteed bitrate DL>[,<Delivery order>[,<Maximum SDU size>[,<SDU error ratio>[,<Residual bit error ratio>[,<Delivery of erroneous SDUs>[,<Transfer delay>[,<Traffic handling priority>]]]]]]]]]]]]

+CME ERROR: <err>

Execution Command Responses

AT+CGEQREQ OK

Defined values

<cid> Parameter specifies a particular PDP context definition.The parameter is also used in other PDP

Page 283: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 282

context-related commands. 1…16

<Traffic class> 0 – conversational 1 – streaming 2 – interactive 3 – background 4 – subscribed value

<Maximum bitrate UL> This parameter indicates the maximum number of kbits/s delivered to UMTS(up-link traffic)at a SAP.As an example a bitrate of 32kbit/s would be specified as 32(e.g. AT+CGEQREQ=…,32,…).

0 subscribed value 1kbps…63kbps – value needs to be divisible by 1 without remainder 64 kbps …568kbps –value needs to be divisible by 8kbps with remainder 64 kbps 576 kbps …8640kbps –value needs to be divisible by 64kbps with remainder 576 kbps

<Maximum bitrate DL> This parameter indicates the maximum number of kbits/s delivered to UMTS(down-link traffic)at a SAP.As an example a bitrate of 32kbit/s would be specified as 32(e.g. AT+CGEQREQ=…,32,…).

0 subscribed value 1kbps…63kbps – value needs to be divisible by 1 without remainder 64 kbps …568kbps –value needs to be divisible by 8kbps with remainder 64 kbps 576 kbps …8640kbps –value needs to be divisible by 64kbps with remainder 576 kbps

<Guaranteed bitrate UL> This parameter indicates the guaranteed number of kbit/s delivered to UMTS(up-link traffic)at a SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as32(e.g.AT+CGEQREQ=…,32,…).

0 subscribed value 1kbps…63kbps – value needs to be divisible by 1 without remainder 64 kbps …568kbps –value needs to be divisible by 8kbps with remainder 64 kbps 576 kbps …8640kbps –value needs to be divisible by 64kbps with remainder 576 kbps

<Guaranteed bitrate DL> This parameter indicates the guaranteed number of kbit/s delivered to UMTS(down-link traffic)at a SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as32(e.g.AT+CGEQREQ=…,32,…).

0 subscribed value 1kbps…63kbps – value needs to be divisible by 1 without remainder 64 kbps …568kbps –value needs to be divisible by 8kbps with remainder 64 kbps 576 kbps …8640kbps –value needs to be divisible by 64kbps with remainder 576 kbps

<Delivery order> This parameter indicates whether the UMTS bearer shall provide in-sequence SDU delivery or not.

0 – no 1 – yes 2 – subscribed value

Page 284: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 283

<Maximum SDU size> This parameter indicates the maximum allowed SDU size in octets.

0 – subscribed value 10…1520 (value needs to be divisible by 10 without remainder)

<SDU error ratio> This parameter indicates the target value for the fraction of SDUs lost or detected as erroneous.SDU error ratio is defined only for conforming traffic.As an example a target SDU error ratio of 5*10-3 would be specified as “5E3”(e.g.AT+CGEQREQ=..,”5E3”,…).

“0E0” – subscribed value “1E2” “7E3” “1E3” “1E4” “1E5” “1E6” “1E1”

<Residual bit error ratio> This parameter indicates the target value for the undetected bit error ratio in the delivered SDUs. If no error detection is requested,Residual bit error ratio indicates the bit error ratio in the delivered SDUs.As an example a target residual bit error ratio of 5*10-3 would be specified as “5E3”(e.g. AT+CGEQREQ=…,”5E3”,..). “0E0” – subscribed value

“5E2” “1E2” “5E3” “4E3” “1E3” “1E4” “1E5” “1E6” “6E8”

<Delivery of erroneous SDUs> This parameter indicates whether SDUs detected as erroneous shall be delivered or not.

0 – no 1 – yes 2 – no detect 3 – subscribed value

<Transfer delay> This parameter indicates the targeted time between request to transfer an SDU at one SAP to its delivery at the other SAP,in milliseconds.

0 – subscribed value 10…150 – value needs to be divisible by 10 without remainder 200…950 – value needs to be divisible by 50 without remainder

Page 285: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 284

1000…4000 – value needs to be divisible by 100 without remainder <Traffic handling priority> This parameter specifies the relative importance for handling of all SDUs belonging to the UMTS Bearer compared to the SDUs of the other bearers.

0 – subscribed value 1 – 2 – 3 –

<PDP_type> (Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.

IP Internet Protocol PPP Point to Point Protocol IPV6 Internet Protocol Version 6

Examples

AT+CGEQREQ? +CGEQREQ: OK AT+CGEQREQ=? +CGEQREQ: "IP",(0-4),(0-384),(0-7168),(0-384),(0-7168),(0-2),(0-1520),("0E0","1E 1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E 4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) +CGEQREQ: "PPP",(0-4),(0-384),(0-7168),(0-384),(0-7168),(0-2),(0-1520),("0E0","1 E1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1 E4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) +CGEQREQ: "IPV6",(0-4),(0-384),(0-7168),(0-384),(0-7168),(0-2),(0-1520),("0E0"," 1E1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3"," 1E4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) OK

15.6 AT+CGQMIN Quality of service profile (minimum acceptable)

Description The command allows the TE to specify a minimum acceptable profile which is checked by the MT against the negotiated profile returned in the Activate PDP Context Accept message.A special form of the set command,AT+CGQMIN=<cid> causes the minimum acceptable profile for context number <cid> to become undefined. SIM PIN References

YES 3GPP TS 27.007

Syntax

Page 286: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 285

Test Command Responses +CGQMIN: <PDP_type>, (list of supported <precedence>s), (list of supported <delay>s), (list of supported <reliability>s) , (list of supported <peak>s), (list of supported <mean>s) [<CR><LF> +CGQMIN: <PDP_type>, (list of supported <precedence>s), (list of supported <delay>s), (list of supported <reliability>s) , (list of supported <peak>s), (list of supported <mean>s)[…]] OK

AT+CGQMIN=?

ERROR

Read Command Responses +CGQMIN: [<cid>, <precedence >, <delay>, <reliability>, <peak>, <mean>[<CR><LF> +CGQMIN: <cid>, <precedence >, <delay>, <reliability.>, <peak>, <mean> […]]] OK

AT+CGQMIN?

ERROR

Write Command Responses OK AT+CGQMIN=

<cid>[,<precedence> [,<delay>[,<reliability> [,<peak> [,<mean>]]]]]

ERROR

Execution Command Responses AT+CGQMIN OK

Defined values

<cid> A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT command).

1...16 <PDP_type> (Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.

IP Internet Protocol PPP Point to Point Protocol IPV6 Internet Protocol Version 6

<precedence> A numeric parameter which specifies the precedence class:

0 – network subscribed value 1 – high priority 2 – normal priority 3 – low priority

Page 287: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 286

<delay> A numeric parameter which specifies the delay class:

0 – network subscribed value 1 – delay class 1 2 – delay class 2 3 – delay class 3 4 – delay class 4

<reliability> A numeric parameter which specifies the reliability class:

0 – network subscribed value 1 – Non real-time traffic,error-sensitive application that cannot cope with data loss 2 – Non real-time traffic,error-sensitive application that can cope with infrequent data loss 3 – Non real-time traffic,error-sensitive application that can cope with data loss, GMM/-

SM,and SMS 4 – Real-time traffic,error-sensitive application that can cope with data loss 5 – Real-time traffic error non-sensitive application that can cope with data loss

<peak> A numeric parameter which specifies the peak throughput class:

0 – network subscribed value 1 – Up to 1000 (8 kbit/s) 2 – Up to 2000 (16 kbit/s) 3 – Up to 4000 (32 kbit/s) 4 – Up to 8000 (64 kbit/s) 5 – Up to 16000 (128 kbit/s) 6 – Up to 32000 (256 kbit/s) 7 – Up to 64000 (512 kbit/s) 8 – Up to 128000 (1024 kbit/s) 9 – Up to 256000 (2048 kbit/s)

<mean> A numeric parameter which specifies the mean throughput class:

0 – network subscribed value 1 – 100 (~0.22 bit/s) 2 – 200 (~0.44 bit/s) 3 – 500 (~1.11 bit/s) 4 – 1000 (~2.2 bit/s) 5 – 2000 (~4.4 bit/s) 6 – 5000 (~11.1 bit/s) 7 – 10000 (~22 bit/s) 8 – 20000 (~44 bit/s) 9 – 50000 (~111 bit/s) 10 – 100000 (~0.22 kbit/s) 11 – 200000 (~0.44 kbit/s) 12 – 500000 (~1.11 kbit/s)

Page 288: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 287

13 – 1000000 (~2.2 kbit/s) 14 – 2000000 (~4.4 kbit/s) 15 – 5000000 (~11.1 kbit/s) 16 – 10000000 (~22 kbit/s) 17 – 20000000 (~44 kbit/s) 18 – 50000000 (~111 kbit/s) 31 – optimization

Examples

AT+CGQMIN? +CGQMIN: OK AT+CGQMIN=? +CGQMIN: "IP",(0-3),(0-4),(0-5),(0-9),(0-18,31) +CGQMIN: "PPP",(0-3),(0-4),(0-5),(0-9),(0-18,31) +CGQMIN: "IPV6",(0-3),(0-4),(0-5),(0-9),(0-18,31) OK

15.7 AT+CGEQMIN 3G quality of service profile (minimum

acceptable)

Description The test command returns values supported as a compound value. The read command returns the current settings for each defined context for which a QOS was explicitly specified. The write command allow the TE to specify a Quallity of Service Profile for the context identified by the context identification parameter <cid> which is checked by the MT against the negotiated profile returned in the Activate/Modify PDP Context Accept message. A special form of the write command, AT+CGEQMIN=<cid> causes the requested for context number <cid> to become undefined. SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses

Page 289: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 288

AT+CGEQMIN=? +CGEQMIN: <PDP_type>,(list of supported <Traffic class>s),(list of supported <Maximum bitrate UL>s),(list of supported <Maxim um bitrate DL>s),(list of supported <Guaranteed bitrate UL>s,(list of supported <Guaranteed bitrate DL>s),(list of supported <Deliv ery order>s),(list of supported <Maximum SDU size>s),(list of supported <SDU error ratio>s),(list of supported <Residual bit errorRatio>s),(list of supported <Delivery of erroneous SDUs>s),(list of Supported <Transfer delay>s),(list of supported <Traffic handling priority>s) OK

Read Command Responses AT+CGEQMIN? +CGEQMIN: [<cid>,<Traffic class>,<Maximum bitrate UL>,<Ma

ximum bitrate DL>,<Guaranteed bitrate UL>,<Guaranteed bitrate DL>,<Delivery order>,<Maximum SDU size>,<SDU error ratio>, <Residual bit error ratio>,<Delivery of erroneous SDUs>,<TransferDelay>,<Traffic handling priority>][<CR><LF> +CGEQMIN: <cid>,<Traffic class>,<Maximum bitrate UL>,<Ma ximum bitrate DL>,<Guaranteed bitrate UL>,<Guaranteed bitrate DL>,<Delivery order>,<Maximum SDU size>,<SDU error ratio>, <Residual bit error ratio>,<Delivery of erroneous SDUs>,<TransferDelay>,<Traffic handling priority>[…]] OK

Write Command Responses OK

ERROR

AT+CGEQMIN=<cid>[,<Traffic class>[,<Maximum bitrate UL>[,<Maximum bitrate DL>[,<Guaranteed bitrateUL>[,<Guaranteed bitrate DL>[,<Delivery order>[,<Maximum SDU size>[,<SDU error ratio>[,<Residual bit error ratio>[,<Delivery of erroneous SDUs>[,<Transfer delay>[,<Traffic handling priority>]]]]]]]]]]]]

+CME ERROR: <err>

Execution Command Responses

AT+CGEQMIN OK

Defined values

<cid> Parameter specifies a particular PDP context definition.The parameter is also used in other PDP

Page 290: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 289

context-related commands. 1…16

<Traffic class> 0 – conversational 1 – streaming 2 – interactive 3 – background 4 – subscribed value

<Maximum bitrate UL> This parameter indicates the maximum number of kbits/s delivered to UMTS(up-link traffic)at a SAP.As an example a bitrate of 32kbit/s would be specified as 32(e.g. AT+CGEQMIN=…,32,…).

0 subscribed value 1kbps…63kbps – value needs to be divisible by 1 without remainder 64 kbps …568kbps –value needs to be divisible by 8kbps with remainder 64 kbps 576 kbps …8640kbps –value needs to be divisible by 64kbps with remainder 576 kbps

<Maximum bitrate DL> This parameter indicates the maximum number of kbits/s delivered to UMTS(down-link traffic)at a SAP.As an example a bitrate of 32kbit/s would be specified as 32(e.g. AT+CGEQMIN=…,32,…).

0 subscribed value 1kbps…63kbps – value needs to be divisible by 1 without remainder 64 kbps …568kbps –value needs to be divisible by 8kbps with remainder 64 kbps 576 kbps …8640kbps –value needs to be divisible by 64kbps with remainder 576 kbps

<Guaranteed bitrate UL> This parameter indicates the guaranteed number of kbit/s delivered to UMTS(up-link traffic)at a SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as32(e.g.AT+CGEQMIN=…,32,…).

0 subscribed value 1kbps…63kbps – value needs to be divisible by 1 without remainder 64 kbps …568kbps –value needs to be divisible by 8kbps with remainder 64 kbps 576 kbps …8640kbps –value needs to be divisible by 64kbps with remainder 576 kbps

<Guaranteed bitrate DL> This parameter indicates the guaranteed number of kbit/s delivered to UMTS(down-link traffic)at a SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as32(e.g.AT+CGEQMIN=…,32,…).

0 subscribed value 1kbps…63kbps – value needs to be divisible by 1 without remainder 64 kbps …568kbps –value needs to be divisible by 8kbps with remainder 64 kbps 576 kbps …8640kbps –value needs to be divisible by 64kbps with remainder 576 kbps

<Delivery order> This parameter indicates whether the UMTS bearer shall provide in-sequence SDU delivery or not.

0 – no 1 – yes 2 – subscribed value

Page 291: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 290

<Maximum SDU size> This parameter indicates the maximum allowed SDU size inoctets.

0 – subscribed value 10…1520 (value needs to be divisible by 10 without remainder)

<SDU error ratio> This parameter indicates the target value for the fraction of SDUs lost or detected as erroneous.SDU error ratio is defined only for conforming traffic.As an example a target SDU error ratio of 5*10-3 would be specified as “5E3”(e.g.AT+CGEQMIN=..,”5E3”,…).

“0E0” – subscribed value “1E2” “7E3” “1E3” “1E4” “1E5” “1E6” “1E1”

<Residual bit error ratio> This parameter indicates the target value for the undetected bit error ratio in the delivered SDUs. If no error detection is requested,Residual bit error ratio indicates the bit error ratio in the delivered SDUs.As an example a target residual bit error ratio of 5*10-3 would be specified as “5E3”(e.g. AT+CGEQMIN=…,”5E3”,..). “0E0” – subscribed value

“5E2” “1E2” “5E3” “4E3” “1E3” “1E4” “1E5” “1E6” “6E8”

<Delivery of erroneous SDUs> This parameter indicates whether SDUs detected as erroneous shall be delivered or not.

0 – no 1 – yes 2 – no detect 3 – subscribed value

<Transfer delay> This parameter indicates the targeted time between request to transfer an SDU at one SAP to its delivery at the other SAP,in milliseconds.

0 – subscribed value 10…150 – value needs to be divisible by 10 without remainder 200…950 – value needs to be divisible by 50 without remainder

Page 292: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 291

1000…4000 – value needs to be divisible by 100 without remainder <Traffic handling priority> This parameter specifies the relative importance for handling of all SDUs belonging to the UMTS Bearer compared to the SDUs of the other bearers.

0 – subscribed value 1 – 2 – 3 –

<PDP_type> (Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.

IP Internet Protocol PPP Point to Point Protocol IPV6 Internet Protocol Version 6

Examples

AT+CGEQMIN? +CGEQMIN: OK AT+CGEQMIN=? +CGEQMIN: "IP",(0-4),(0-384),(0-7168),(0-384),(0-7168),(0-2),(0-1520),("0E0","1E 1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E 4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) +CGEQMIN: "PPP",(0-4),(0-384),(0-7168),(0-384),(0-7168),(0-2),(0-1520),("0E0","1 E1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1 E4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) +CGEQMIN: "IPV6",(0-4),(0-384),(0-7168),(0-384),(0-7168),(0-2),(0-1520),("0E0"," 1E1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3"," 1E4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) OK

15.8 AT+CGATT Packet domain attach or detach

Description The write command is used to attach the MT to, or detach the MT from, the Packet Domain service.The read command returns the current Packet Domain service state.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses

Page 293: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 292

AT+CGATT=? +CGATT: (list of supported <state>s) OK

Read Command Responses AT+CGATT? +CGATT: <state>

OK

Write Command Responses OK

ERROR

AT+CGATT=<state>

+CME ERROR: <err>

Defined values

<state> Indicates the state of Packet Domain attachment:

0 – detached 1 – attached

Examples

AT+CGATT? +CGATT: 0 OK AT+CGATT=1 OK

15.9 AT+CGACT PDP context activate or deactivate

Description The write command is used to activate or deactivate the specified PDP context (s).

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CGACT=? +CGACT: (list of supported <state>s)

OK

Read Command Responses AT+CGACT? +CGACT: [<cid>, <state>[<CR><LF>

+CGACT: <cid>, <state> [...]]]

Page 294: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 293

OK

Write Command Responses OK

ERROR

AT+CGACT=<state> [,<cid>]

+CME ERROR: <err>

Defined values

<state> Indicates the state of PDP context activation:

0 – deactivated 1 – activated

<cid> A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT command).

1…16

Examples

AT+CGACT? +CGACT: 1,0 OK AT+CGACT=? +CGACT: (0,1) OK AT+CGACT=0,1 OK

15.10 AT+CGDATA Enter data state

Description The command causes the MT to perform whatever actions are necessary to establish communication between the TE and the network using one or more Packet Domain PDP types. This may include performing a PS attach and one or more PDP context activations.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CGDATA=? +CGDATA: (list of supported <L2P>s)

OK

Page 295: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 294

Write Command Responses CONNECT

NO CARRIER

ERROR

AT+CGDATA=<L2P>,[<cid>]

+CME ERROR: <err>

Defined values

<L2P> A string parameter that indicates the layer 2 protocol to be used between the TE and MT.

PPP Point-to-point protocol for a PDP such as IP <cid> A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT command).

1…16

Examples

AT+CGDATA=? +CGDATA: ("PPP") OK AT+CGDATA="PPP",1 CONNECT

15.11 AT+CGPADDR Show PDP address

Description The write command returns a list of PDP addresses for the specified context identifiers.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CGPADDR=? +CGPADDR: (list of defined <cid>s)

OK

Write Command Responses [+CGPADDR:<cid>,<PDP_addr>[<CR><LF> +CGPADDR: <cid>,<PDP_addr>[...]]] OK

AT+CGPADDR= <cid>[,<cid>[,…]]

ERROR

Page 296: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 295

+CME ERROR: <err> Execution Command Responses

[+CGPADDR: <cid>,<PDP_addr>] +CGPADDR: <cid>,<PDP_addr>[...]]] OK

ERROR

AT+CGPADDR

+CME ERROR: <err>

Defined values

<cid> A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT command). If no <cid> is specified, the addresses for all defined contexts are returned.

1…16 <PDP_addr> A string that identifies the MT in the address space applicable to the PDP. The address may be static or dynamic. For a static address, it will be the one set by the AT+CGDCONT command when the context was defined. For a dynamic address it will be the one assigned during the last PDP context activation that used the context definition referred to by <cid>. <PDP_addr> is omitted if none is available.

Examples

AT+CGPADDR =? +CGPADDR: ( 1) OK AT+CGPADDR=1 +CGPADDR: 1,"0.0.0.0" OK

15.12 AT+CGCLASS GPRS mobile station class

Description The command is used to set the MT to operate according to the specified GPRS mobile class.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CGCLASS=? +CGCLASS: (list of supported <class>s)

Page 297: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 296

OK

ERROR

Read Command Responses +CGCLASS: <class> OK

AT+CGCLASS?

ERROR

Write Command Responses OK

ERROR

AT+CGCLASS=<class>

+CME ERROR: <err> Execution Command Responses

Set default value: OK

AT+CGCLASS

ERROR

Defined values

<class> A string parameter which indicates the GPRS mobile class (in descending order of functionality)

A – class A (highest)

Examples

AT+CGCLASS=? +CGCLASS: ("A") OK AT+CGCLASS? +CGCLASS: "A" OK

15.13 AT+CGEREP GPRS event reporting

Description The write command enables or disables sending of unsolicited result codes, “+CGEV” from MT to TE in the case of certain events occurring in the Packet Domain MT or the network. <mode> controls the processing of unsolicited result codes specified within this command. <bfr> controls the effect on buffered codes when <mode> 1 or 2 is entered. If a setting is not supported by the MT, ERROR or +CME ERROR: is returned. Read command returns the current <mode> and buffer settings. Test command returns the modes and buffer settings supported by the MT as compound values. SIM PIN References

Page 298: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 297

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CGEREP=? +CGEREP: (list of supported <mode>s),(list of supported <bfr>s)

OK

Read Command Responses AT+CGEREP? +CGEREP: <mode>,<bfr>

OK

Write Command Responses OK

ERROR

AT+CGEREP= <mode>[,<bfr>]

+CME ERROR: <err> Execution Command Responses AT+CGEREP OK

Defined values

<mode> 0 – buffer unsolicited result codes in the MT; if MT result code buffer is full, the oldest

ones can be discarded. No codes are forwarded to the TE. 1 – discard unsolicited result codes when MT-TE link is reserved (e.g. in on-line data

mode); otherwise forward them directly to the TE. 2 – buffer unsolicited result codes in the MT when MT-TE link is reserved (e.g. in on-line

data mode) and flush them to the TE when MT-TE link becomes available; otherwise forward them directly to the TE.

<bfr> 0 – MT buffer of unsolicited result codes defined within this command is cleared when

<mode> 1 or 2 is entered. 1 – MT buffer of unsolicited result codes defined within this command is flushed to the TE

when <mode> 1 or 2 is entered (OK response shall be given before flushing the codes).The following unsolicited result codes and the corresponding events are defined:

+CGEV: REJECT <PDP_type>, <PDP_addr> A network request for PDP context activation occurred when the MT was unable to report it to the TE with a +CRING unsolicited result code and was automatically rejected.

+CGEV: NW REACT <PDP_type>, <PDP_addr>, [<cid>] The network has requested a context reactivation. The <cid> that was used to reactivate the context is provided if known to the MT.

+CGEV: NW DEACT <PDP_type>, <PDP_addr>, [<cid>] The network has forced a context deactivation. The <cid> that was used to activate the

Page 299: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 298

context is provided if known to the MT. +CGEV: ME DEACT <PDP_type>, <PDP_addr>, [<cid>]

The mobile equipment has forced a context deactivation. The <cid> that was used to activate the context is provided if known to the MT.

+CGEV: NW DETACH The network has forced a Packet Domain detach. This implies that all active contexts have been deactivated. These are not reported separately.

+CGEV: ME DETACH The mobile equipment has forced a Packet Domain detach. This implies that all active contexts have been deactivated. These are not reported separately.

+CGEV: NW CLASS <class> The network has forced a change of MS class. The highest available class is reported (see AT+CGCLASS).

+CGEV: ME CLASS <class> The mobile equipment has forced a change of MS class. The highest available class is reported (see AT+CGCLASS).

Examples

AT+CGEREP=? +CGEREP: (0-2),(0-1) OK AT+CGEREP? +CGEREP: 0,0 OK

15.14 AT+CGREG GPRS network registration status

Description The command controls the presentation of an unsolicited result code “+CGREG: <stat>” when <n>=1 and there is a change in the MT's GPRS network registration status. The read command returns the status of result code presentation and an integer <stat> which shows Whether the network has currently indicated the registration of the MT. SIM PIN References

NO 3GPP TS 27.007

Syntax

Test Command Responses AT+CGREG=? +CGREG: (list of supported <n>s)

OK

Read Command Responses

Page 300: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 299

AT+CGREG? +CGREG: <n>,<stat>[,<lac>,<ci>] OK

Write Command Responses AT+CGREG=<n> OK Execution Command Responses AT+CGREG Set default value:

OK

Defined values

Examples

AT+CGREG=? +CGREG: (0-1) OK AT+CGREG? +CGREG: 0,0 OK

15.15 AT+CGSMS Select service for MO SMS messages

Description

<n> 0 – disable network registration unsolicited result code 1 – enable network registration unsolicited result code +CGREG: <stat> 2 – there is a change in the ME network registration status or a change of the network cell: +CGREG: <stat>[,<lac>,<ci>]

<stat> 0 – not registered, ME is not currently searching an operator to register to 1 – registered, home network 2 – not registered, but ME is currently trying to attach or searching an operator to register

to 3 – registration denied 4 – unknown 5 – registered, roaming

<lac> Two byte location area code in hexadecimal format(e.g.”00C3” equals 193 in decimal). <ci> Two byte cell ID in hexadecimal format.

Page 301: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 300

The write command is used to specify the service or service preference that the MT will use to send MO SMS messages. The test command is used for requesting information on which services and service preferences can be set by using the AT+CGSMS write command The read command returns the currently selected service or service preference. SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CGSMS=? +CGSMS: (list of supported <service>s)

OK

Read Command Responses AT+CGSMS? +CGSMS: <service>

OK

Write Command Responses OK

ERROR

AT+CGSMS=<service>

+CME ERROR: <err>

Defined values

<service> A numeric parameter which indicates the service or service preference to be used

0 – GPRS(value is not really supported and is internally mapped to 2) 1 – circuit switched(value is not really supported and is internally mapped to 3) 2 – GPRS preferred (use circuit switched if GPRS not available) 3 – circuit switched preferred (use GPRS if circuit switched not available)

Examples

AT+CGSMS? +CGSMS: 3 OK AT+CGSMS=? +CGSMS: (0-3) OK

Page 302: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 301

15.16 AT+CGAUTH Set type of authentication for PDP-IP connections

of GPRS

Description The command is used to set type of authentication for PDP-IP connections of GPRS.

SIM PIN References

YES Vendor

Syntax

Test Command Responses +CGAUTH:(range of supported <cid>s),(list of supported <auth _- type> s),, OK

ERROR

AT+CGAUTH=?

+CME ERROR: <err>

Read Command Responses +CGAUTH: <cid>,<auth_type>[,<user>]<CR><LF> +CGAUTH: <cid>,<auth_type>[,<user>]<CR><LF> … OK

ERROR

AT+CGAUTH?

+CME ERROR: <err>

Write Command Responses OK

ERROR

AT+CGAUTH=<cid>[,<auth_type>[,<passwd>[,<user>]]] +CME ERROR: <err> Execution Command Responses

OK

ERROR

AT+CGAUTH

+CME ERROR: <err>

Defined values

<cid> Parameter specifies a particular PDP context definition. This is also used in other PDP context-related commands.

1…16

Page 303: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 302

<auth_type> Indicates the types of authentication to be used for the specified context. If CHAP is selected another parameter <passwd> needs to be specified. If PAP is selected two additional parameters <passwd> and <user> need to specified.

0 – none 1 – PAP 2 – CHAP

<passwd> Parameter specifies the password used for authentication. It is required for the authentication types PAP and CHAP. <user> Parameter specifies the user name used for authentication. It is required for the authentication type PAP.

Examples

AT+CGAUTH=? +CGAUTH: (1-16),(0-2), OK AT+CGAUTH=1,1,”SIMCOM”,”123” OK

Page 304: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 303

16 TCP/IP Related Commands

16.1 AT+CGSOCKCONT Define socket PDP context

Description The command specifies socket PDP context parameter values for a PDP context identified by the (local) context identification parameter <cid>. The number of PDP contexts that may be in a defined state at the same time is given by the range returned by the test command. A special form of the write command (AT+CGSOCKCONT=<cid>) causes the values for context <cid> to become undefined. SIM PIN References

YES Vendor

Syntax

Test Command Responses +CGSOCKCONT: (range of supported<cid>s),<PDP_type>,,,(list of supported <d_comp>s),(list of supported <h_comp>s) OK

AT+CGSOCKCONT=?

ERROR

Read Command Responses +CGSOCKCONT: [<cid>, <PDP_type>, <APN>,<PDP_addr>, <d_comp>, <h_comp>[<CR><LF> +CGSOCKCONT: <cid>, <PDP_type>, <APN>, <PDP_addr>, <d_comp>, <h_comp>[...]]] OK

AT+CGSOCKCONT?

ERROR

Write Command Responses OK AT+CGSOCKCONT=

<cid>[,<PDP_type> [,<APN>[,<PDP_addr> [,<d_comp>[,<h_comp>]]]]]

ERROR

Execution Command Responses OK AT+CGSOCKCONT

ERROR

Defined values

Page 305: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 304

<cid> (PDP Context Identifier) a numeric parameter which specifies a particular PDP context definition. The parameter is local to the TE-MT interface and is used in other PDP context-related commands. The range of permitted values (minimum value = 1) is returned by the test form of the command.

1…16 <PDP_type> (Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.

IP Internet Protocol PPP Point to Point Protocol IPV6 Internet Protocol Version 6

<APN> (Access Point Name) a string parameter which is a logical name that is used to select the GGSN or the external packet data network. <PDP_addr> A string parameter that identifies the MT in the address space applicable to the PDP. Read command will continue to return the null string even if an address has been allocated during the PDP startup procedure. <d_comp> A numeric parameter that controls PDP data compression:

0 – off (default if value is omitted) 1 – on

<h_comp> A numeric parameter that controls PDP header compression:

0 – off (default if value is omitted) 1 – on

Examples

AT+CGSOCKCONT? +CGSOCKDCONT: 1,"IP","","0.0.0.0",0,0 OK AT+CGSOCKCONT=? +CGSOCKCONT: (1-16),"IP",,,(0,1),(0,1) +CGSOCKCONT: (1-16),"PPP",,,(0,1),(0,1) +CGSOCKCONT: (1-16),"IPV6",,,(0,1),(0,1) OK

16.2 AT+CSOCKSETPN Set active PDP context’s profile number

Description

Page 306: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 305

The command sets default active PDP context’s profile number. When we activate PDP by using AT+NETOPEN command, we need use the default profile number, and the context of this profile is set by AT+CGSOCKCONT command.

SIM PIN References

YES Vendor

Syntax

Test Command Responses +CSOCKSETPN: (list of supported <profile_number>s) OK

AT+CSOCKSETPN=?

ERROR

Read Command Responses + CSOCKSETPN: <profile_number> OK

AT+CSOCKSETPN?

ERROR

Write Command Responses OK AT+CSOCKSETPN=

<profile_number> ERROR Execution Command Responses

OK AT+CSOCKSETPN

ERROR

Defined values

<profile_number> A numeric parameter that identifies default profile number, the range of permitted values is one to sixteen.

1…16

Examples

AT+CSOCKSETPN=1 OK

16.3 AT+CSOCKAUTH Set type of authentication for PDP-IP

conne-ctions of socket

Description The command is used to set type of authentication for PDP-IP connections of socket.

Page 307: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 306

SIM PIN References

YES Vendor

Syntax

Test Command Responses +CSOCKAUTH:(range of supported <cid>s),(list of supported <auth _type> s), <passwd_len>,<user_len> OK

ERROR

AT+CSOCKAUTH=?

+CME ERROR: <err>

Read Command Responses +CSOCKAUTH: <cid>,<auth_type>[,<user>]<CR><LF> +CSOCKAUTH: <cid>,<auth_type>[,<user>]<CR><LF> … OK

ERROR

AT+CSOCKAUTH?

+CME ERROR: <err>

Write Command Responses OK

ERROR

AT+CSOCKAUTH=<cid> [,<auth_type>[,<passwd>[,<user>]]] +CME ERROR: <err> Execution Command Responses

OK

ERROR

AT+CSOCKAUTH

+CME ERROR: <err>

Defined values

<cid> Parameter specifies a particular PDP context definition. This is also used in other PDP context-related commands.

1…16 <auth_type> Indicates the types of authentication to be used for the specified context. If CHAP is selected another parameter <passwd> needs to be specified. If PAP is selected two additional parameters <passwd> and <user> need to specified.

0 – none 1 – PAP 2 – CHAP

<passwd>

Page 308: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 307

Parameter specifies the password used for authentication. It is required for the authentication types PAP and CHAP. <user> Parameter specifies the user name used for authentication. It is required for the authentication type PAP. <passwd_len> The maximum length of the password. <user_len> The maximum length of the user name.

Examples

AT+CSOCKAUTH=? +CSOCKAUTH: (1-16),(0-2),132,132 OK AT+CSOCKAUTH=1,1,”SIMCOM”,”123” OK

16.4 AT+CGSOCKQREQ Quality of service profile (requested)

Description The command allows the TE to specify a Quality of Service Profile that is used when the MT sends an Activate PDP Context Request message to the network.. A special form of the set command (AT+CGSOCKQREQ=<cid>) causes the requested profile for context number <cid> to become undefined. This command only affects the embedded socket related PDP context definition (refer to AT+CGSOCKCONT). SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses +CGSOCKQREQ: <PDP_type>, (list of supported <precedence>s), (list of supported <delay>s), (list of supported <reliability>s) , (list of supported <peak>s), (list of supported <mean>s) [<CR><LF> +CGSOCKQREQ: <PDP_type>, (list of supported <precedence>s), (list of supported <delay>s), (list of supported <reliability>s) , (list of supported <peak>s), (list of supported <mean>s) […]] OK

AT+CGSOCKQREQ=?

ERROR

Page 309: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 308

Read Command Responses +CGSOCKQREQ: [<cid>, <precedence >, <delay>, <reliability>, <peak>, <mean>[<CR><LF> +CGSOCKQREQ: <cid>, <precedence >, <delay>, <reliability.>, <peak>, <mean>[…]]] OK

AT+CGSOCKQREQ?

ERROR

Write Command Responses OK AT+CGSOCKQREQ=<cid>

[,<precedence> [,<delay>[,<reliability> [,<peak> [,<mean>]]]]]

ERROR

Execution Command Responses

OK AT+CGSOCKQREQ

ERROR

Defined values

<cid> A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT command).

1…16 <PDP_type> (Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.

IP Internet Protocol PPP Point to Point Protocol IPV6 Internet Protocol Version 6

<precedence> A numeric parameter which specifies the precedence class:

0 – network subscribed value 1 – high priority 2 – normal priority 3 – low priority

<delay> A numeric parameter which specifies the delay class:

0 – network subscribed value 1 – delay class 1 2 – delay class 2 3 – delay class 3 4 – delay class 4

<reliability> A numeric parameter which specifies the reliability class:

Page 310: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 309

0 – network subscribed value 1 – Non real-time traffic,error-sensitive application that cannot cope with data loss 2 – Non real-time traffic,error-sensitive application that can cope with infrequent data loss 3 – Non real-time traffic,error-sensitive application that can cope with data loss, GMM/-

SM,and SMS 4 – Real-time traffic,error-sensitive application that can cope with data loss 5 – Real-time traffic error non-sensitive application that can cope with data loss

<peak> A numeric parameter which specifies the peak throughput class:

0 – network subscribed value 1 – Up to 1000 (8 kbit/s) 2 – Up to 2000 (16 kbit/s) 3 – Up to 4000 (32 kbit/s) 4 – Up to 8000 (64 kbit/s) 5 – Up to 16000 (128 kbit/s) 6 – Up to 32000 (256 kbit/s) 7 – Up to 64000 (512 kbit/s) 8 – Up to 128000 (1024 kbit/s) 9 – Up to 256000 (2048 kbit/s)

<mean> A numeric parameter which specifies the mean throughput class:

0 – network subscribed value 1 – 100 (~0.22 bit/s) 2 – 200 (~0.44 bit/s) 3 – 500 (~1.11 bit/s) 4 – 1000 (~2.2 bit/s) 5 – 2000 (~4.4 bit/s) 6 – 5000 (~11.1 bit/s) 7 – 10000 (~22 bit/s) 8 – 20000 (~44 bit/s) 9 – 50000 (~111 bit/s) 10 – 100000 (~0.22 kbit/s) 11 – 200000 (~0.44 kbit/s) 12 – 500000 (~1.11 kbit/s) 13 – 1000000 (~2.2 kbit/s) 14 – 2000000 (~4.4 kbit/s) 15 – 5000000 (~11.1 kbit/s) 16 – 10000000 (~22 kbit/s) 17 – 20000000 (~44 kbit/s) 18 – 50000000 (~111 kbit/s) 31 – optimization

Examples

Page 311: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 310

AT+CGSOCKQREQ? +CGSOCKQREQ: OK AT+CGSOCKQREQ=? +CGSOCKQREQ: "IP",(0-3),(0-4),(0-5),(0-9),(0-18,31) +CGSOCKQREQ: "PPP",(0-3),(0-4),(0-5),(0-9),(0-18,31) +CGSOCKQREQ: "IPV6",(0-3),(0-4),(0-5),(0-9),(0-18,31) OK

16.5 AT+CGSOCKEQREQ 3G quality of service profile (requested)

Description The test command returns values supported as a compound value. The read command returns the current settings for each defined context for which a QOS was explicitly specified. The write command allows the TE to specify a Quality of Service Profile for the context identified by the context identification parameter <cid> which is used when the MT sends an Activate PDP Context Request message to the network. A special form of the write command,AT+CGSOCKEQREQ=<cid> causes the requested profile for context number <cid> to become undefined. This command only affects the embedded socket related PDP context definition (refer to AT+CGSOCKCONT). SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CGSOCKEQREQ=? +CGSOCKEQREQ: <PDP_type>,(list of supported <Traffic

class>s),(list of supported <Maximum bitrate UL>s),(list of supported <Maxim um bitrate DL>s),(list of supported <Guaranteed bitrate UL>s,(list of supported <Guaranteed bitrate DL>s),(list of supported <Deliv ery order>s),(list of supported <Maximum SDU size>s),(list of supported <SDU error ratio>s),(list of supported <Residual bit error Ratio>s),(list of supported <Delivery of erroneous SDUs>s),(list of Supported <Transfer delay>s),(list of supported <Traffic handling priority>s) [<CR><LF> +CGSOCKEQREQ: <PDP_type>,(list of supported <Traffic class>s),(list of supported <Maximum bitrate UL>s),(list of supported <Maxim um bitrate DL>s),(list of supported <Guaranteed bitrate UL>s,(list of supported <Guaranteed bitrate

Page 312: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 311

DL>s),(list of supported <Deliv ery order>s),(list of supported <Maximum SDU size>s),(list of supported <SDU error ratio>s),(list of supported <Residual bit error Ratio>s),(list of supported <Delivery of erroneous SDUs>s),(list of Supported <Transfer delay>s),(list of supported <Traffic handling priority>s) […]] OK

Read Command Responses AT+CGSOCKEQREQ? +CGSOCKEQREQ: [<cid>,<Traffic class>,<Maximum bitrate

UL>,<Ma ximum bitrate DL>,<Guaranteed bitrate UL>,<Guaranteed bitrate DL>,<Delivery order>,<Maximum SDU size>,<SDU error ratio>, <Residual bit error ratio>,<Delivery of erroneous SDUs>,<TransferDelay>,<Traffic handling priority>][<CR><LF> +CGSOCKEQREQ: <cid>,<Traffic class>,<Maximum bitrate UL>,<Ma ximum bitrate DL>,<Guaranteed bitrate UL>,<Guaranteed bitrate DL>,<Delivery order>,<Maximum SDU size>,<SDU error ratio>, <Residual bit error ratio>,<Delivery of erroneous SDUs>,<TransferDelay>,<Traffic handling priority>[…]] OK

Write Command Responses OK

ERROR

AT+CGSOCKEQREQ=<cid>[,<Traffic class>[,<Maximum bitrate UL>[,<Maximum bitrate DL>[,<Guaranteed bitrateUL>[,<Guaranteed bitrate DL>[,<Delivery order>[,<Maximum SDU size>[,<SDU error ratio>[,<Residual bit error ratio>[,<Delivery of erroneous SDUs>[,<Transfer delay>[,<Traffic handling priority>]]]]]]]]]]]]

+CME ERROR: <err>

Execution Command Responses

AT+CGSOCKEQREQ OK

Defined values

Page 313: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 312

<cid> Parameter specifies a particular PDP context definition.The parameter is also used in other PDP context-related commands.

1…16 <Traffic class>

0 – conversational 1 – streaming 2 – interactive 3 – background 4 – subscribed value

<Maximum bitrate UL> This parameter indicates the maximum number of kbits/s delivered to UMTS(up-link traffic)at a SAP.As an example a bitrate of 32kbit/s would be specified as 32(e.g. AT+CGSOCKEQREQ=…,32,…).

0 subscribed value 1kbps…63kbps – value needs to be divisible by 1 without remainder 64 kbps …568kbps –value needs to be divisible by 8kbps with remainder 64 kbps 576 kbps …8640kbps –value needs to be divisible by 64kbps with remainder 576 kbps

<Maximum bitrate DL> This parameter indicates the maximum number of kbits/s delivered to UMTS(down-link traffic)at a SAP.As an example a bitrate of 32kbit/s would be specified as 32(e.g. AT+CGSOCKEQREQ=…,32,…).

0 subscribed value 1kbps…63kbps – value needs to be divisible by 1 without remainder 64 kbps …568kbps –value needs to be divisible by 8kbps with remainder 64 kbps 576 kbps …8640kbps –value needs to be divisible by 64kbps with remainder 576 kbps

<Guaranteed bitrate UL> This parameter indicates the guaranteed number of kbit/s delivered to UMTS(up-link traffic)at a SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as32(e.g.AT+CGSOCKEQREQ=…,32,…).

0 subscribed value 1kbps…63kbps – value needs to be divisible by 1 without remainder 64 kbps …568kbps –value needs to be divisible by 8kbps with remainder 64 kbps 576 kbps …8640kbps –value needs to be divisible by 64kbps with remainder 576 kbps

<Guaranteed bitrate DL> This parameter indicates the guaranteed number of kbit/s delivered to UMTS(down-link traffic)at a SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as32(e.g.AT+CGSOCKEQREQ=…,32,…).

0 subscribed value 1kbps…63kbps – value needs to be divisible by 1 without remainder 64 kbps …568kbps –value needs to be divisible by 8kbps with remainder 64 kbps 576 kbps …8640kbps –value needs to be divisible by 64kbps with remainder 576 kbps

<Delivery order>

Page 314: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 313

This parameter indicates whether the UMTS bearer shall provide in-sequence SDU delivery or not. 0 – no 1 – yes 2 – subscribed value

<Maximum SDU size> This parameter indicates the maximum allowed SDU size in octets.

0 – subscribed value 10…1520 (value needs to be divisible by 10 without remainder)

<SDU error ratio> This parameter indicates the target value for the fraction of SDUs lost or detected as erroneous.SDU error ratio is defined only for conforming traffic.As an example a target SDU error ratio of 5*10-3 would be specified as “5E3”(e.g.AT+CGSOCKEQREQ=..,”5E3”,…).

“0E0” – subscribed value “1E2” “7E3” “1E3” “1E4” “1E5” “1E6” “1E1”

<Residual bit error ratio> This parameter indicates the target value for the undetected bit error ratio in the delivered SDUs. If no error detection is requested,Residual bit error ratio indicates the bit error ratio in the delivered SDUs.As an example a target residual bit error ratio of 5*10-3 would be specified as “5E3”(e.g. AT+CGSOCKEQREQ=…,”5E3”,..). “0E0” – subscribed value

“5E2” “1E2” “5E3” “4E3” “1E3” “1E4” “1E5” “1E6” “6E8”

<Delivery of erroneous SDUs> This parameter indicates whether SDUs detected as erroneous shall be delivered or not.

0 – no 1 – yes 2 – no detect 3 – subscribed value

<Transfer delay> This parameter indicates the targeted time between request to transfer an SDU at one SAP to its

Page 315: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 314

delivery at the other SAP,in milliseconds. 0 – subscribed value 10…150 – value needs to be divisible by 10 without remainder 200…950 – value needs to be divisible by 50 without remainder 1000…4000 – value needs to be divisible by 100 without remainder

<Traffic handling priority> This parameter specifies the relative importance for handling of all SDUs belonging to the UMTS Bearer compared to the SDUs of the other bearers.

0 – subscribed value 1 – 2 – 3 –

<PDP_type> (Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.

IP Internet Protocol PPP Point to Point Protocol IPV6 Internet Protocol Version 6

Examples

AT+CGSOCKEQREQ? +CGSOCKEQREQ: OK AT+CGSOCKEQREQ =? +CGSOCKEQREQ: "IP",(0-4),(0-384),(0-384),(0-384),(0-384),(0-2),(0-1520),("0E0","1E1" ,"1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E4" ,"1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) +CGSOCKEQREQ: "PPP",(0-4),(0-384),(0-384),(0-384),(0-384),(0-2),(0-1520),("0E0","1E1 ","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E4 ","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) +CGSOCKEQREQ: "IPV6",(0-4),(0-384),(0-384),(0-384),(0-384),(0-2),(0-1520),("0E0","1E 1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E 4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) OK

16.6 AT+CGSOCKQMIN Quality of service profile (minimum

acceptable)

Description The command allows the TE to specify a minimum acceptable profile which is checked by the MT against the negotiated profile returned in the Activate PDP Context Accept message.A special form of the set command,AT+CGSOCKQMIN=<cid> causes the minimum acceptable profile for context

Page 316: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 315

number <cid> to become undefined. This command only affects the embedded socket related PDP context definition (refer to AT+CGSOCKCONT). SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses +CGSOCKQMIN: <PDP_type>, (list of supported <precedence>s), (list of supported <delay>s), (list of supported <reliability>s) , (list of supported <peak>s), (list of supported <mean>s) [<CR><LF> +CGSOCKQMIN: <PDP_type>, (list of supported <precedence>s), (list of supported <delay>s), (list of supported <reliability>s) , (list of supported <peak>s), (list of supported <mean>s)[…]] OK

AT+CGSOCKQMIN=?

ERROR

Read Command Responses +CGSOCKQMIN: [<cid>, <precedence >, <delay>, <reliability>, <peak>, <mean>[<CR><LF> +CGSOCKQMIN: <cid>, <precedence >, <delay>, <reliability.>, <peak>, <mean> […]]] OK

AT+CGSOCKQMIN?

ERROR

Write Command Responses OK AT+CGSOCKQMIN=

<cid>[,<precedence> [,<delay>[,<reliability> [,<peak> [,<mean>]]]]]

ERROR

Execution Command Responses AT+CGSOCKQMIN OK

Defined values

<cid> A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT command).

1...16 <PDP_type> (Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.

IP Internet Protocol

Page 317: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 316

PPP Point to Point Protocol IPV6 Internet Protocol Version 6

<precedence> A numeric parameter which specifies the precedence class:

0 – network subscribed value 1 – high priority 2 – normal priority 3 – low priority

<delay> A numeric parameter which specifies the delay class:

0 – network subscribed value 1 – delay class 1 2 – delay class 2 3 – delay class 3 4 – delay class 4

<reliability> A numeric parameter which specifies the reliability class:

0 – network subscribed value 1 – Non real-time traffic,error-sensitive application that cannot cope with data loss 2 – Non real-time traffic,error-sensitive application that can cope with infrequent data loss 3 – Non real-time traffic,error-sensitive application that can cope with data loss, GMM/-

SM,and SMS 4 – Real-time traffic,error-sensitive application that can cope with data loss 5 – Real-time traffic error non-sensitive application that can cope with data loss

<peak> A numeric parameter which specifies the peak throughput class:

0 – network subscribed value 1 – Up to 1000 (8 kbit/s) 2 – Up to 2000 (16 kbit/s) 3 – Up to 4000 (32 kbit/s) 4 – Up to 8000 (64 kbit/s) 5 – Up to 16000 (128 kbit/s) 6 – Up to 32000 (256 kbit/s) 7 – Up to 64000 (512 kbit/s) 8 – Up to 128000 (1024 kbit/s) 9 – Up to 256000 (2048 kbit/s)

<mean> A numeric parameter which specifies the mean throughput class:

0 – network subscribed value 1 – 100 (~0.22 bit/s) 2 – 200 (~0.44 bit/s) 3 – 500 (~1.11 bit/s) 4 – 1000 (~2.2 bit/s)

Page 318: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 317

5 – 2000 (~4.4 bit/s) 6 – 5000 (~11.1 bit/s) 7 – 10000 (~22 bit/s) 8 – 20000 (~44 bit/s) 9 – 50000 (~111 bit/s) 10 – 100000 (~0.22 kbit/s) 11 – 200000 (~0.44 kbit/s) 12 – 500000 (~1.11 kbit/s) 13 – 1000000 (~2.2 kbit/s) 14 – 2000000 (~4.4 kbit/s) 15 – 5000000 (~11.1 kbit/s) 16 – 10000000 (~22 kbit/s) 17 – 20000000 (~44 kbit/s) 18 – 50000000 (~111 kbit/s) 31 – optimization

Examples

AT+CGSOCKQMIN? +CGSOCKQMIN: OK AT+CGSOCKQMIN=? +CGSOCKQMIN: "IP",(0-3),(0-4),(0-5),(0-9),(0-18,31) +CGSOCKQMIN: "PPP",(0-3),(0-4),(0-5),(0-9),(0-18,31) +CGSOCKQMIN: "IPV6",(0-3),(0-4),(0-5),(0-9),(0-18,31) OK

16.7 AT+CGSOCKEQMIN 3G quality of service profile (minimum

acceptable)

Description The test command returns values supported as a compound value. The read command returns the current settings for each defined context for which a QOS was explicitly specified. The write command allow the TE to specify a Quallity of Service Profile for the context identified by the context identification parameter <cid> which is checked by the MT against the negotiated profile returned in the Activate/Modify PDP Context Accept message. A special form of the write command, AT+CGSOCKEQMIN=<cid> causes the requested for context number <cid> to become undefined. This command only affects the embedded socket related PDP context definition (refer to AT+CGSOCKCONT).

Page 319: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 318

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CGSOCKEQMIN=? +CGSOCKEQMIN: <PDP_type>,(list of supported <Traffic

class>s),(list of supported <Maximum bitrate UL>s),(list of supported <Maxim um bitrate DL>s),(list of supported <Guaranteed bitrate UL>s,(list of supported <Guaranteed bitrate DL>s),(list of supported <Deliv ery order>s),(list of supported <Maximum SDU size>s),(list of supported <SDU error ratio>s),(list of supported <Residual bit error Ratio>s),(list of supported <Delivery of erroneous SDUs>s),(list of Supported <Transfer delay>s),(list of supported <Traffic handling priority>s) [<CR><LF> +CGSOCKEQMIN: <PDP_type>,(list of supported <Traffic class>s),(list of supported <Maximum bitrate UL>s),(list of supported <Maxim um bitrate DL>s),(list of supported <Guaranteed bitrate UL>s,(list of supported <Guaranteed bitrate DL>s),(list of supported <Deliv ery order>s),(list of supported <Maximum SDU size>s),(list of supported <SDU error ratio>s),(list of supported <Residual bit error Ratio>s),(list of supported <Delivery of erroneous SDUs>s),(list of Supported <Transfer delay>s),(list of supported <Traffic handling priority>s) […]] OK

Read Command Responses AT+CGSOCKEQMIN? +CGSOCKEQMIN: [<cid>,<Traffic class>,<Maximum bitrate

UL>,<Ma ximum bitrate DL>,<Guaranteed bitrate UL>,<Guaranteed bitrate DL>,<Delivery order>,<Maximum SDU size>,<SDU error ratio>, <Residual bit error ratio>,<Delivery of erroneous SDUs>,<TransferDelay>,<Traffic handling priority>][<CR><LF> +CGSOCKEQMIN: <cid>,<Traffic class>,<Maximum bitrate UL>,<Ma ximum bitrate DL>,<Guaranteed bitrate UL>,<Guaranteed bitrate DL>,<Delivery order>,<Maximum SDU size>,<SDU error ratio>, <Residual bit error ratio>,<Delivery of erroneous SDUs>,<TransferDelay>,<Traffic handling priority>[…]] OK

Write Command Responses

Page 320: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 319

OK

ERROR

AT+CGSOCKEQMIN=<cid>[,<Traffic class>[,<Maximum bitrate UL>[,<Maximum bitrate DL>[,<Guaranteed bitrateUL>[,<Guaranteed bitrate DL>[,<Delivery order>[,<Maximum SDU size>[,<SDU error ratio>[,<Residual bit error ratio>[,<Delivery of erroneous SDUs>[,<Transfer delay>[,<Traffic handling priority>]]]]]]]]]]]]

+CME ERROR: <err>

Execution Command Responses

AT+CGSOCKEQMIN OK

Defined values

<cid> Parameter specifies a particular PDP context definition.The parameter is also used in other PDP context-related commands.

1…16 <Traffic class>

0 – conversational 1 – streaming 2 – interactive 3 – background 4 – subscribed value

<Maximum bitrate UL> This parameter indicates the maximum number of kbits/s delivered to UMTS(up-link traffic)at a SAP.As an example a bitrate of 32kbit/s would be specified as 32(e.g. AT+CGSOCKEQMIN=…,32,…). (refer TS 24.008 [8] subclause 10.5.6.5).

0 subscribed value 1kbps…63kbps – value needs to be divisible by 1 without remainder 64 kbps …568kbps –value needs to be divisible by 8kbps with remainder 64 kbps 576 kbps …8640kbps –value needs to be divisible by 64kbps with remainder 576 kbps

<Maximum bitrate DL> This parameter indicates the maximum number of kbits/s delivered to UMTS(down-link traffic)at a SAP.As an example a bitrate of 32kbit/s would be specified as 32(e.g. AT+CGSOCKEQMIN=…,32,…). (refer TS 24.008 [8] subclause 10.5.6.5).

0 subscribed value 1kbps…63kbps – value needs to be divisible by 1 without remainder 64 kbps …568kbps –value needs to be divisible by 8kbps with remainder 64 kbps

Page 321: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 320

576 kbps …8640kbps –value needs to be divisible by 64kbps with remainder 576kbps <Guaranteed bitrate UL> This parameter indicates the guaranteed number of kbit/s delivered to UMTS(up-link traffic)at a SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as32(e.g.AT+CGSOCKEQMIN=…,32,…). (refer TS 24.008 [8] subclause 10.5.6.5).

0 subscribed value 1kbps…63kbps – value needs to be divisible by 1 without remainder 64 kbps …568kbps –value needs to be divisible by 8kbps with remainder 64kbps 576 kbps …8640kbps –value needs to be divisible by 64kbps with remainder 576kbps

<Guaranteed bitrate DL> This parameter indicates the guaranteed number of kbit/s delivered to UMTS(down-link traffic)at a SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as32(e.g.AT+CGSOCKEQMIN=…,32,…). (refer TS 24.008 [8] subclause 10.5.6.5).

0 subscribed value 1kbps…63kbps – value needs to be divisible by 1 without remainder 64 kbps …568kbps –value needs to be divisible by 8kbps with remainder 64kbps 576 kbps …8640kbps –value needs to be divisible by 64kbps with remainder 576kbps

<Delivery order> This parameter indicates whether the UMTS bearer shall provide in-sequence SDU delivery or not.

0 – no 1 – yes 2 – subscribed value

<Maximum SDU size> This parameter indicates the maximum allowed SDU size inoctets. (refer TS 24.008 [8] subclause 10.5.6.5).

0 – subscribed value 10…1520 (value needs to be divisible by 10 without remainder)

<SDU error ratio> This parameter indicates the target value for the fraction of SDUs lost or detected as erroneous.SDU error ratio is defined only for conforming traffic.As an example a target SDU error ratio of 5*10-3 would be specified as “5E3”(e.g.AT+CGSOCKEQMIN=..,”5E3”,…).

“0E0” – subscribed value “1E2” “7E3” “1E3” “1E4” “1E5” “1E6” “1E1”

<Residual bit error ratio> This parameter indicates the target value for the undetected bit error ratio in the delivered SDUs. If no error detection is requested,Residual bit error ratio indicates the bit error ratio in the delivered SDUs.As an example a target residual bit error ratio of 5*10-3 would be specified as “5E3”(e.g.

Page 322: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 321

AT+ CGSOCKEQMIN =…,”5E3”,..). “0E0” – subscribed value

“5E2” “1E2” “5E3” “4E3” “1E3” “1E4” “1E5” “1E6” “6E8”

<Delivery of erroneous SDUs> This parameter indicates whether SDUs detected as erroneous shall be delivered or not.

0 – no 1 – yes 2 – no detect 3 – subscribed value

<Transfer delay> This parameter indicates the targeted time between request to transfer an SDU at one SAP to its delivery at the other SAP,in milliseconds. (refer TS 24.008 [8] subclause 10.5.6.5).

0 – subscribed value 10…150 – value needs to be divisible by 10 without remainder 200…950 – value needs to be divisible by 50 without remainder 1000…4000 – value needs to be divisible by 100 without remainder

<Traffic handling priority> This parameter specifies the relative importance for handling of all SDUs belonging to the UMTS Bearer compared to the SDUs of the other bearers.

0 – subscribed value 1 – 2 – 3 –

<PDP_type> (Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.

IP Internet Protocol PPP Point to Point Protocol IPV6 Internet Protocol Version 6

Examples

AT+CGSOCKEQMIN? + CGSOCKEQMIN: OK AT+CGSOCKEQMIN =?

Page 323: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 322

+CGSOCKEQMIN: "IP",(0-4),(0-384),(0-384),(0-384),(0-384),(0-2),(0-1520),("0E0","1E1" ,"1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E4" ,"1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) +CGSOCKEQMIN: "PPP",(0-4),(0-384),(0-384),(0-384),(0-384),(0-2),(0-1520),("0E0","1E1 ","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E4 ","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) +CGSOCKEQMIN: "IPV6",(0-4),(0-384),(0-384),(0-384),(0-384),(0-2),(0-1520),("0E0","1E 1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E 4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) OK

16.8 AT+IPADDR Inquire socket PDP address

Description The command inquires the IP address of current active socket PDP.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+IPADDR=? OK Execution Command Responses

+IPADDR: < ip_address> OK

+IP ERROR:<err_info> ERROR

AT+IPADDR

ERROR

Defined values

<ip_address> A string parameter that identifies the IP address of current active socket PDP. <err_info> A string parameter that displays the cause of occurring error.

Examples

AT+IPADDR +IPADDR: 10.71.155.118 OK

Page 324: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 323

16.9 AT+NETOPEN Open socket

Description The command opens socket, and it can also activate the socket PDP context at the same time. For the write command, if the first and second parameters are empty, the third parameter must exist; If the third parameter is empty, the first and second parameters must exist. SIM PIN References

YES Vendor

Syntax

Test Command Responses +NETOPEN: (list of supported <sock_type>s), (range of supported <port>s), (list of supported <mode>s) OK

ERROR

AT+NETOPEN=?

+CME ERROR: <err>

Read Command Responses +NETOPEN:<net_state>, <mode> OK

ERROR

AT+NETOPEN?

+CME ERROR: <err>

Write Command Responses Network opened OK

+IP ERROR: <err_info> ERROR

AT+NETOPEN= [<sock_type>][,[<port>] [, <mode>]]

+CME ERROR: <err>

Defined values

<sock_type> a string parameter that identifies the type of transmission protocol.

TCP – Transfer Control Protocol UDP – User Datagram Protocol

When it is “TCP” and only one parameter exists, the AT+TCPCLOSE command can be used to close the socket created. <port> A numeric parameter that identifies the port of socket, the range of permitted values is 0 to 65535. <net_state>

Page 325: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 324

a numeric parameter that indicates the state of PDP context activation: 0 network close (deactivated) 1 network open(activated)

<mode> a numeric parameter that module is used which mode.At present, it supports three mode,such as single-client, tcp-server and multi-client.if <mode> is 1,then <sock_type> and <port> are ignored.

0 single-client or tcp-server 1 multi-client

<err_info> A string parameter that displays the cause of occurring error.

Examples

AT+NETOPEN=”TCP”,80 Network opened OK AT+NETOPEN=? +NETOPEN: ("TCP", "UDP"), (0-65535), (0-1) OK AT+NETOPEN? +NETOPEN: 1, 1 OK

16.10 AT+TCPCONNECT Establish TCP connection

Description The command establishes TCP connection with TCP server.

SIM PIN References

YES Vendor

Syntax

Test Command Responses OK

ERROR

AT+TCPCONNECT =?

+CME ERROR: <err>

Write Command Responses Connect ok OK

AT+TCPCONNECT= <server_IP>, <port>

+IP ERROR: <err_info> ERROR

Page 326: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 325

Connect fail ERROR

ERROR

Defined values

<server_IP> A string parameter that identifies the IP address of TCP server.The IP address format consists of 4 octets,separated by decimal point:”AAA.BBB.CCC.DDD”.In the latest software version,it already Supports DNS query,so it may be a string like “www.google.cn.”. <port> A numeric parameter that identifies the port of TCP server, the range of permitted values is 0 to 65535. <err_info> A string parameter that displays the cause of occurring error.

Examples

AT+TCPCONNECT=”192.168.0.1”,80 OK AT+TCPCONNECT=”192.168.0.1”,80 Connect fail ERROR AT+TCPCONNECT=”www.google.cn”,80 OK

16.11 AT+TCPWRITE Send TCP data

Description The command sends TCP data when the TCP connection is established.

SIM PIN References

YES Vendor

Syntax

Test Command Responses OK

ERROR

AT+TCPWRITE=?

+CME ERROR: <err>

Write Command Responses

Page 327: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 326

OK +TCPWRITE: <reqSendLength>, <cnfSendLength> If sending successfully: Send ok

+IP ERROR: <err_info> ERROR

AT+TCPWRITE=<length> <CR>data for send

ERROR

Defined values

<length> a numeric parameter which indicates the length of sending data, it must be between1 and 1024. <reqSendLength> a numeric parameter that requested number of data bytes to be transmitted. <cnfSendLength> a numeric parameter that confirmed number of data bytes to be transmitted.

-1 the connection is disconnected. 0 own send buffer or other side’s congestion window are full. <err_info> A string parameter that displays the cause of occurring error.

Examples

AT+TCPWRITE=12 >ABCDEFGHIJKL OK +TCPWRITE:12, 12 Send ok

16.12 AT+UDPSEND Send UDP data

Description The command sends UDP data.

SIM PIN References

YES Vendor

Syntax

Page 328: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 327

Test Command Responses OK

ERROR

AT+UDPSEND =?

+CME ERROR: <err>

Write Command Responses OK +UDPSEND: <reqSendLength>, <cnfSendLength>

+IP ERROR: <err_info> ERROR

AT+UDPSEND=<length>,<IP_address>,<port><CR> data for send

ERROR

Defined values

<length> a numeric parameter which indicates the length of sending data, it must be between1 and 1024. <IP_address> A string parameter that identifies the IP address of receiver.The IP address format consists of 4 octets,separated by decimal point:”AAA.BBB.CCC.DDD”.In the latest software version,it already Supports DNS query,so it may be a string like “www.google.cn.”. <port> A numeric parameter that identifies the port of receiver, the range of permitted values is 0 to 65535.<reqSendLength> a numeric parameter that requested number of data bytes to be transmitted. <cnfSendLength> a numeric parameter that confirmed number of data bytes to be transmitted.

-1 the connection is disconnected. 0 own send buffer or other side’s congestion window are full. <err_info> A string parameter that displays the cause of occurring error.

Examples

AT+UDPSEND=12,”192.168.0.1”,80 >ABCDEFGHIJKL OK +UDPSEND: 12, 12

16.13 AT+SERVERSTART Startup TCP server

Description

Page 329: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 328

The command starts up TCP server, and the server can receive the request of TCP client. After the command executes successfully, an unsolicited result code is returned when a client tries to connect with module and module accepts request.The unsolicited result code is +CLIENT: <client_IP>:<port>. NOTE: If the module is as a server, this need the Operators to support. SIM PIN References

YES Vendor

Syntax

Test Command Responses OK AT+SERVERSTART=?

ERROR

Read Command Responses +SERVERSTART: <state> OK

AT+SERVERSTART?

+IP ERROR: <err_info> ERROR

Write Command Responses

OK AT+SERVERSTART=<port> +IP ERROR: <err_info>

ERROR

Execution Command Responses

+IP ERROR: <err_info> ERROR

AT+SERVERSTART

OK

Defined values

<client_IP> A string parameter that identifies the IP address of client. <port> The port to listen on. This parameter can only be used when AT+NETOPEN=”TCP” is launched. <state> The state of the server socket: - LISTENING - NOT LISTENING <err_info> A string parameter that displays the cause of occurring error.

Examples

Page 330: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 329

AT+SERVERSTART OK At+SERVERSTART? +SERVERSTART: LISTENING OK

16.14 AT+LISTCLIENT List all of clients’ information

Description The command lists all of clients’ information, and these clients have already been connected with TCP server.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+LISTCLIENT=? OK

Write Command Responses [+LISTCLIENT: <index1>, <IP_address>, <port>] … [+LISTCLIENT: <indexN>, <IP_address>, <port>] OK

+IP ERROR: <err_info> ERROR

AT+LISTCLIENT

ERROR

Defined values

<indexX> A numeric parameter that identifies the index of client, the max number of client is ten, and the range of permitted values is 0 to 9. <IP_address> A string parameter that identifies the IP address of client. <port> A numeric parameter that identifies the port of client, the range of permitted values is 0 to 65535. <err_info> A string parameter that displays the cause of occurring error.

Examples

AT+LISTCLIENT

Page 331: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 330

+LISTCLIENT: 0, 10.71.34.32 , 80 +LISTCLIENT: 1, 10.71.78.89, 1020 OK

16.15 AT+CLOSECLIENT Disconnect specified client

Description The command disconnects the specified client.if the client disconnects connection, an unsolicited result code is returned.The unsolicited result code is +IPCLOSE: <client_index>, <close_reason>,<remote_IP>,<port>.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CLOSECLIENT=? OK

Write Command Responses OK

+IP ERROR: <err_info> ERROR

AT+CLOSECLIENT= <client_index>

ERROR

Defined values

<client_index> A numeric parameter that identifies the client index which will be closed, The allocated index may be read using command AT+LISTCLIENT. <close_reason> a numeric parameter that identifies reason that the connection closed.

1 remote side sends a request of closing first. 2 reset the connection because of timeout of sending data,or other reasons.

<remote_IP> A string parameter that identifies the IP address of client. <port> A numeric parameter that identifies the port of client. <err_info> A string parameter that displays the cause of occurring error.

Page 332: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 331

Examples

AT+CLOSECLIENT=0 OK

16.16 AT+ACTCLIENT Activate specified client

Description The command activates the specified client, when the client is activated, the client is able to receive data from TCP server or send data to the TCP server.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+ACTCLIENT=? OK

Write Command Responses OK

+IP ERROR: <err_info> ERROR

AT+ACTCLIENT= <client_index>

ERROR

Defined values

<client_index> A numeric parameter that identifies the client index which will be closed. The allocated index may be read using command AT+LISTCLIENT. <err_info> A string parameter that displays the cause of occurring error.

Examples

AT+ ACTCLIENT=0 OK

16.17 AT+NETCLOSE Close socket

Description The command closes socket, if the socket is opened for a server, then it will disconnect all of clients’ connection that is connected with the server.

Page 333: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 332

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+NETCLOSE =? OK

Execution Command Responses OK

+IP ERROR: <err_info> ERROR

AT+NETCLOSE

ERROR

Defined values

<err_info> A string parameter that displays the cause of occurring error.

Examples

AT+NETCLOSE Network closed OK

16.18 AT+CIPHEAD Add an IP head when receiving data

Description The command is used to add an IP head when receiving data. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CIPHEAD=? +CIPHEAD: (list of supported<mode>s)

OK

Read Command Responses AT+CIPHEAD? +CIPHEAD: <mode>

OK

Write Command Responses AT+CIPHEAD=<mode> OK

Page 334: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 333

ERROR Execution Command Responses

AT+CIPHEAD Set default value: OK

Defined values

<mode> a numeric parameter which indicates whether adding an IP header to received data or not 0 – not add IP header 1 – add IP header, the format is “+IPD(data length)”

Examples

AT+CIPHEAD=? +CIPHEAD: (0-1) OK AT+CIPHEAD=0 OK

16.19 AT+CIPSRIP Set whether display IP address and port of sender

when receiving data

Description The command is used to set whether display IP address and port of sender when receiving data. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CIPSRIP=? +CIPSRIP: (list of supported <mode>s)

OK

Read Command Responses AT+CIPSRIP? +CIPSRIP: <mode>

OK

Write Command Responses OK AT+CIPSRIP=<mode>

ERROR Execution Command Responses

Page 335: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 334

AT+CIPSRIP Set default value: OK

Defined values

<mode> a numeric parameter which indicates whether show the prompt of where the data received or not before received data.

0 – do not show the prompt 1 – show the prompt,the format is as follows:

“RECV FROM:<IP ADDRESS>:<PORT>”

Examples

AT+CIPSRIP=? +CIPSRIP: (0-1) OK AT+CIPSRIP=1 OK

16.20 AT+CIPCCFG Configure parameters of socket

Description The command is used to configure parameters of socket. For the write command, the parameter part cannot be empty. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CIPCCFG=? +CIPCCFG: (list of supported <NmRetry>s),(list of supported

<DelayTm>s),(list of supported <Ack>s), (list of supported <errMode>s),(list of supported <HeaderType>s) OK

Read Command Responses AT+CIPCCFG? +CIPCCFG:<NmRetry>,<DelayTm>,<Ack>,<errMode>,<Header-

Type> OK

Write Command Responses AT+CIPCCFG= OK

Page 336: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 335

[<NmRetry>][,[<DelayTm>][,[<Ack>][,[<errMode>][,]<HeaderType>]]]]]

ERROR

Execution Command Responses AT+CIPCCFG Set default value:

OK

Defined values

<NmRetry> a numeric parameter which is number of retransmission to be made for an IP packet.The default value is 10. <DelayTm> a numeric parameter which is number of milliseconds to delay to output data of Receiving.The default value is 0. <Ack> a numeric parameter which sets whether reporting a string “Send ok” when sending some data as a tcp connection.

0 not reporting 1 reporting

<errMode> a numeric parameter which sets mode of reporting error result code.

0 error result code with numeric values 1 error result code with string values

< HeaderType > a numeric parameter that select which data header of receiving data, it only takes effect in multi-client mode.

0 add data header, the format is “+IPD(data length)” 1 add data header, the format is “+RECEIVE,<link num>,<data length>”

Examples

AT+CIPCCFG=? +CIPCCFG: (3-10),(0-1000),(0-1),(0-1),(0-1) OK AT+CIPCCFG=3,500,1,1,1 OK

16.21 AT+CIPOPEN Establish connection in multi-client mode

Description The command is used to establish a connection with TCP server and UDP server, The sum of all of connections are 10。

Page 337: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 336

SIM PIN References

YES Vendor

Syntax

Test Command Responses +CIPOPEN: (list of supported <link_num>s), (list of supported <type>s) OK

ERROR

AT+CIPOPEN=?

+CME ERROR: <err>

Read Command Responses +CIPOPEN: <link_num> [,<type>,<serverIP>,<serverPort>] +CIPOPEN: <link_num> [,<type>,<serverIP>,<serverPort>] […] OK

+IP ERROR: <err_info> ERROR

AT+CIPOPEN?

+CME ERROR: <err>

Write Command Responses Connect ok(if tcp connect) OK

+IP ERROR: <err_info> ERROR

AT+CIPOPEN= <link_num>,”TCP”,<serverIP>,<serverPort>[,<localPort>]

+CME ERROR: <err>

OK(if udp open)

+IP ERROR: <err_info> ERROR

AT+CIPOPEN= <link_num>,”UDP”,,,<localPort>

+CME ERROR: <err>

Defined values

<link_num> a numeric parameter that identifies a connection. the range of permitted values is 0 to 9. <type> a string parameter that identifies the type of transmission protocol.

TCP Transfer Control Protocol UDP User Datagram Protocol

<serverIP> A string parameter that identifies the IP address of server.The IP address format consists of 4 octets,separated by decimal point:”AAA.BBB.CCC.DDD”.In the latest software version,it already

Page 338: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 337

Supports DNS query,so it may be a string like “www.google.cn.”. <serverPort> a numeric parameter that identifies the port of TCP server, the range of permitted values is 0 to 65535.

NOTE: When open port as TCP, the port must be the opened TCP port; When open port as UDP, the port may be any port.

But, for Qualcomm, connecting the port 0 is as an invalid operation. <localPort> a numeric parameter that identifies the port of local socket, the range of permitted values is 0 to 65535.

<err_info> A string parameter that displays the cause of occurring error.

Examples

AT+CIPOPEN=0,"TCP","116.228.221.51",100 Connect ok OK AT+CIPOPEN=1,"UDP",,,8080 OK AT+CIPOPEN=? +CIPOPEN: (0-9), ("TCP", "UDP") OK AT+CIPOPEN? +CIPOPEN: 0, "TCP", "116.228.221.51", 100 +CIPOPEN: 1 +CIPOPEN: 2 +CIPOPEN: 3 +CIPOPEN: 4 +CIPOPEN: 5 +CIPOPEN: 6 +CIPOPEN: 7 +CIPOPEN: 8 +CIPOPEN: 9 OK AT+CIPOPEN=0,"TCP","www.google.cn",80 Connect ok OK

16.22 AT+CIPSEND Send data in multi-client mode

Description The command sends some data to remote host in mult-client mode.

Page 339: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 338

SIM PIN References

YES Vendor

Syntax

Test Command Responses +CIPSEND: (list of supported <link_num>s), (list of supported < length >s) OK

+IP ERROR: <err_info> ERROR

AT+CIPSEND =?

+CME ERROR: <err>

Read Command Responses OK AT+CIPSEND?

+CME ERROR: <err>

Write Command Responses OK +CIPSEND: <reqSendLength>, <cnfSendLength> If sending successfully(tcp connect): Send ok

+IP ERROR: <err_info> ERROR

AT+CIPSEND=<link_num>,<length><CR>data for send (This format is for TCP connect)

+CME ERROR: <err>

If sending successfully(udp sending): OK +CIPSEND: <reqSendLength>, <cnfSendLength>

+IP ERROR: <err_info> ERROR

AT+CIPSEND=<link_num>,<length>,<serverIP>,<serverPort><CR>data for send (This format is for UDP connect) +CME ERROR: <err>

Defined values

<link_num> a numeric parameter that identifies a connection. the range of permitted values is 0 to 9. <length> a numeric parameter which indicates the length of sending data, it must be between1 and 1024. <serverIP> A string parameter that identifies the IP address of server.The IP address format consists of 4 octets,separated by decimal point:”AAA.BBB.CCC.DDD”.In the latest software version,it already Supports DNS query,so it may be a string like “www.google.cn.”.

Page 340: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 339

<serverPort> a numeric parameter that identifies the port of TCP server, the range of permitted values is 0 to 65535.

NOTE: When open port as TCP, the port must be the opened TCP port; When open port as UDP, the port may be any port.

But, for Qualcomm, connecting the port 0 is as an invalid operation. <reqSendLength> a numeric parameter that requested number of data bytes to be transmitted. <cnfSendLength> a numeric parameter that confirmed number of data bytes to be transmitted.

-1 the connection is disconnected. 0 own send buffer or other side’s congestion window are full.

<err_info> A string parameter that displays the cause of occurring error.

Examples

AT+CIPSEND=0,1 > S OK +CIPSEND: 1, 1 Send ok AT+CIPSEND=1,1,”116.236.221.75”,6775 > S OK +CIPSEND: 1, 1 Send ok AT+CIPSEND=? +CIPSEND: (0-9), (1-1024) OK

16.23 AT+CIPCLOSE Close connection in Multi-client mode

Description The command closes a specified connection in multi-client mode. SIM PIN References

YES Vendor

Page 341: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 340

Syntax

Test Command Responses +CIPCLOSE: (list of supported <link_num>s) OK

AT+CIPCLOSE =?

+CME ERROR: <err>

Read Command Responses +CIPCLOSE:<link0_state>,<link1_state>,<link2_state>, <link3_state>,<link4_state>,<link5_state>,<link6_state>, <link7_state>,<link8_state>,<link9_state> OK

+IP ERROR: <err_info> ERROR

AT+CIPCLOSE ?

+CME ERROR: <err>

Write Command Responses OK

+IP ERROR: <err_info> ERROR

AT+CIPCLOSE= <link_num>

+CME ERROR: <err>

Defined values

<link_num> a numeric parameter that identifies a connection. the range of permitted values is 0 to 9. <linkx_state> a numeric parameter that identifies state of <link_num>. the range of permitted values is 0 to 1. 0 disconnected 1 connected <err_info> A string parameter that displays the cause of occurring error.

Examples

AT+CIPCLOSE? +CIPCLOSE: 1, 0, 0, 0, 0, 0, 0, 0, 0, 0 OK AT+CIPCLOSE=? +CIPCLOSE: (0-9) OK AT+CIPCLOSE=0 OK

Page 342: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 341

16.24 AT+CDNSGIP Query the IP address of given domain name

Description The command is used to query the IP address of given domain name.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CDNSGIP=? OK

Write Command Responses If successful,return: +CDNSGIP: 1,<domain name>,<IP address> OK

If fail,return: +CDNSGIP: 0,<dns error code> ERROR

AT+CDNSGIP=<domain name>

ERROR

Defined values

<domain name> A string parameter (string should be included in quotation marks) which indicates the doma-in name. <IP address> A string parameter (string should be included in quotation marks) which indicates the IP address corresponding to the domain name. <dns error code> A numeric parameter which indicates the error code. 10 DNS GENERAL ERROR

Examples

AT+CDNSGIP=? OK AT+CDNSGIP=”www.google.com” +CDNSGIP: 1, "www.google.com", "203.208.39.99" OK

Page 343: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 342

16.25 AT+CDNSGHNAME Query the domain name of given IP

address

Description The command is used to query the domain name of given IP address.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CDNSGHNAME=? OK

Write Command Responses If successful,return: +CDNSGHNAME: <index>,<domain name>,<IP address> OK

If fail,return: +CDNSGHNAME: 0,<dns error code> ERROR

AT+CDNSGHNAME=<IP address>

ERROR

Defined values

<domain name> A string parameter (string should be included in quotation marks) which indicates the doma-in name. <IP address> A string parameter (string should be included in quotation marks) which indicates the IP address corresponding to the domain name. <dns error code> A numeric parameter which indicates the error code. 10 DNS GENERAL ERROR <index> A numeric parameter which indicates DNS result index. This value is always 1 if performing successfully. Currently only the first record returned from the DNS server will be reported.

Examples

AT+CDNSGHNAME=? OK

Page 344: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 343

AT+CDNSGHNAME=” 58.32.231.148” +CDNSGHNAME: 1, "mail.sim.com", "58.32.231.148" OK

16.26 AT+CIPMODE Select TCPIP application mode

Description The command is used to select TCPIP application modes that includes two modes(normal mode and transparent mode).The default mode is normal mode. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CIPMODE=? +CIPMODE: (list of supported <mode>s)

OK

Read Command Responses AT+CIPMODE? +CIPMODE: <mode>

OK

Write Command Responses OK AT+CIPMODE=<mode>

ERROR

Execution Command Responses AT+CIPMODE Set default value(<mode>=0):

OK

Defined values

<mode> 0 – Normal mode 1 – Transparent mode

Examples

AT+CIPMODE? +CIPMODE: 1 OK AT+CIPMODE=1 OK

Page 345: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 344

AT+CIPMODE=? +CIPMODE: (0-1) OK AT+CIPMODE OK

16.27 AT+CIPSTAT Statistic the total size of data sent or received

Description The command is used to statistics the total size of data sent or received for a socket in multiple socket mode(Only valid for client mode). SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CIPSTAT=? +CIPSTAT: (list of supported <link_num>s)

OK

Write Command Responses +CIPSTAT: <sent_size>, <recv_size> OK

AT+CIPSTAT=<link_num>

+IP ERROR: <err_info> ERROR

Defined values

< link_num> a numeric parameter that identifies a connection. the range of permitted values is 0 to 9. <sent_size> Total size of sent data. <recv_size> Total size of received data. <err_info> A string parameter that displays the cause of occurring error.

Examples

AT+CIPSTAT=0 +CIPSTAT: 10, 20 OK AT+CIPSTAT=?

Page 346: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 345

+CIPSTAT: (0-9) OK

16.28 AT+CTCPFIN Wait for TCP_FIN in TCP_FINWAIT2 state

Description The command is used to configure whether the module should wait for TCP_FIN in TCP_FINWAIT2 state. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CTCPFIN=? +CTCPFIN: (list of supported <TCP_FIN_Enable>s),(list of

supported <DelayTm>s) OK

Read Command Responses AT+CTCPFIN? +CTCPFIN:<TCP_FIN_Enable>,<DelayTm>

OK

Write Command Responses OK AT+CTCPFIN=

<TCP_FIN_Enable>, <DelayTm> ERROR

Defined values

< TCP_FIN_Enable > a numeric parameter which sets whether waiting for TCP_FIN inTCP_FINWAIT2 state.

0 not waiting 1 waiting

<DelayTm> a numeric parameter which is number of seconds to delay before closing the PS network. This parameter only affects the AT+NETCLOSE command when using single TCP/UDP mode.

Examples

AT+CTCPFIN=? +CTCPFIN: (0,1),(0-10) OK

Page 347: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 346

AT+CTCPFIN=1,2 OK

16.29 AT+CENDUPPDP Enable duplicate PDP activation

Description The command is used to enable or disable duplicate PDPs activation with the same APN. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CENDUPPDP=? +CENDUPPDP: (list of supported <DUP_PDP_Enable>s)

OK

Read Command Responses AT+CENDUPPDP? +CENDUPPDP:<DUP_PDP_Enable>

OK

Write Command Responses OK AT+CENDUPPDP=

<DUP_PDP_Enable> ERROR

Defined values

<DUP_PDP_Enable> a numeric parameter which sets whether enable duplicate PDPs activation with the same APN.

0 disable 1 enable

Examples

AT+CENDUPPDP=? +CENDUPPDP: (0,1) OK AT+CENDUPPDP=1 OK

Page 348: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 347

16.30 AT+CTCPKA Set TCP_KEEP_ALIVE parameters

Description The command is used to set TCP_KEEP_ALIVE parameters for TCP related AT commands. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CTCPKA=? +CTCPKA: (list of supported <TCP_KA_Enable>s),(list of

supported <KeepIdleTm>s) ,(list of supported <KeepAliveMaxTry>s) OK

Read Command Responses AT+CTCPKA? +CTCPKA:<TCP_KA_Enable>,<KeepIdleTm>,<KeepAliveMaxT

ry> OK

Write Command Responses OK AT+CTCPKA=

<TCP_KA_Enable>,<KeepIdleTm>,<KeepAliveMaxTry>

ERROR

Defined values

< TCP_KA_Enable > a numeric parameter which sets whether enable TCP_KEEP_ALIVE option.

0 disable 1 enable

<KeepIdleTm> a numeric parameter which is number of minutes to delay after last time of sending TCP data. The range is 1 to 120. <KeepAliveMaxTry> Maximum times for sending Keep-Alive checking. The range is 1 to 10.

Examples

AT+CTCPKA=? +CTCPKA: (0,1),(1-120) ,(1-10) OK

Page 349: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 348

AT+CTCPKA=1,3,3 OK

16.31 AT+CPING Ping some destination address

Description The command is used to ping some destination address.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CPING=? +CPING: IP address,(list of supported

<dest_addr_type>s),(1-100) OK

Write Command Responses OK AT+CPING=<dest_addr>,<dest_ad

dr_type>[,<num_pings>] ERROR

Defined values

<dest_addr> The destination is to be pinged; it can be an IP address (IPv4 or IPv6) or a domain name. <dest_addr_type> Integer type. Address family type (IPv4 or IPv6) of the destination address

1 – IPv4. 2 – IPv6.

<num_pings> Integer type. The num_pings specifies the number of times the ping request (1-100) is to be sent. The default value is 4.

Examples

AT+CPING=? +CPING:10086;10010 OK AT+CPING=”www.baidu.com”,1,4 +CPING: Pinging www.baidu.com with 64 bytes of data: OK +CPING: Reply from 119.75.218.45: bytes=64 time=626ms TTL=255 +CPING: Reply from 119.75.218.45: bytes=64 time=2069ms TTL=255

Page 350: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 349

+CPING: Reply from 119.75.218.45: bytes=64 time=2001ms TTL=255 +PING: Request timed out. +CPING: Ping statistics: Packets: Sent = 4, Received = 3, Lost = 1 (25% loss), Approximate round trip times in milli-seconds: Minimum = 626ms, Maximum = 2069ms, Average = 1565ms

16.32 AT+CPINGSTOP Stop an ongoing ping session

Description The command is used to stop an ongoing ping session.

SIM PIN References

YES Vendor

Syntax

Write Command Responses OK AT+CPINGSTOP ERROR

Examples

AT+CPINGSTOP OK

16.33 AT+CTEUTP Set unknown incoming TCP packet echo

Description The command is used to enable or disable unknown incoming TCP packet echo. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CTEUTP=? +CTEUTP: (list of supported <Echo_Unknown_TCP_Enable>s)

OK

Read Command Responses AT+CTEUTP? +CTEUTP:<Echo_Unknown_TCP_Enable>

OK

Page 351: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 350

Write Command Responses OK AT+CTEUTP =

<Echo_Unknown_TCP_Enable> ERROR

Defined values

<Echo_Unknown_TCP_Enable> a numeric parameter which sets whether enable or disable unknown incoming TCP packet echo option.

0 disable 1 enable

Examples

AT+CTEUTP=? +CTEUTP: (0,1) OK AT+CTEUTP=1 OK

16.34 AT+CUPURE Set UDP port unreachable ICMP echo

Description The command is used to enable or disable UDP port unreachable echo. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CUPURE=? +CUPURE: (list of supported

<UDP_PORT_UNREACHABLE_Enable>s) OK

Read Command Responses AT+CUPURE? +CUPURE:< UDP_PORT_UNREACHABLE_Enable>

OK

Write Command Responses AT+CUPURE= OK

Page 352: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 351

<UDP_PORT_UNREACHABLE_Enable>

ERROR

Defined values

<UDP_PORT_UNREACHABLE_Enable> a numeric parameter which sets whether enable or disable UDP port unreachable ICMP echo option.

0 disable 1 enable

Examples

AT+CUPURE=? +CUPURE: (0,1) OK AT+CUPURE=1 OK

16.35 AT+CINICMPALLOW Preferred ICMP filter

Description The command is used to filter the incoming ICMP packets that are not allowed.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CINICMPALLOW=? + CINICMPALLOW: (list of supported <mode>s)

OK

Read Command Responses AT+CINICMPALLOW? +CINICMPALLOW: <mode>

OK

Write Command Responses OK AT+CINICMPALLOW=<m

ode> ERROR

Defined values

<mode>

Page 353: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 352

64bit number, the value is “1” << “<pos>” , then or by bit. <pos> Flag value from 0 to 63. Value:

0 ICMP ECHO REPLY 3 ICMP DESTINATION UNREACH 4 ICMP SOURCE QUENCH 5 ICMP REDIRECT 8 ICMP ECHO REQUEST 9 MIP AGENT ADVERTISEMENT 10 MIP AGENT SOLICITATION 11 TIME-TO-ALIVE EXCEEDED 12 PARAMETER PROBLEM 13 ICMP TIMESTAMP 14 ICMP TIME REPLY 15 INFORMATION REQUEST 16 INFORMATION REPLY 17 ADDRESS MASK REQUEST 18 ADDRESS MASK REPLY 37 DOMAIN NAME REQUEST 38 DOMAIN NAME REPLY

Examples

AT+CINICMPALLOW=0xFFFFFFFFFFFFFEFF OK AT+CINICMPALLOW? +CINICMPALLOW: 0xFFFFFFFFFFFFFEFF OK

16.36 AT+TCPCLOSE Close the TCP connection

Description The command closes TCP connection. This command can only be used when AT+NETOPEN=”TCP” is launched. SIM PIN References

YES Vendor

Syntax

Execution Command Responses AT+TCPCLOSE OK

Page 354: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 353

+IP ERROR: <err_info> ERROR

ERROR

Defined values

<err_info> A string parameter that displays the cause of occurring error.

Examples

AT+TCPCLOSE OK

16.37 Information elements related to TCP/IP

The following table lists information elements which may be returned.It should be noted that TCP/IP socket problems may occur or result may be executed.

Information Description

Network opened Indicate that the write command of AT+NETOPEN has excuted successfully.

Network not opened Indicate that you should execute AT+NE- TOPEN first.

Network is already opened Indicate that the write command of AT+N-ETOPEN has already executed successfully.

Port overflow Indicate that input port is out of range.

Create socket failed Indicate that socket has not been created successfully.

Bind port failed Indicate that input port is already in use.

Connect ok Indicate that establishing a connection successfully.

Connection is already created Indicate that a connection has been already established.

Connect fail Indicate that establishing a connection unsu- ccessfully

No clients connected Indicate that module as TCP server has no any connection.

No active client Indicate that you should execute AT+ACTC- LIENT first and select a connection.

Client index overflow Indicate that input client’s index is out of range.

Page 355: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 354

Connection disconnected Indicate that the remote end has closed the connection.

Socket closed Indicate that socket is closed.

Network closed Indicate that the write command of AT+NETCLOSE has excuted successfully.

Network is already closed Indicate that network has been closed now.

Sending time out Failed to send TCP or UDP data for timer expire.

Sending failure for network error Failed to send data for network error

Open failure for network error Failed to open network for network error.

Server is already listening Server is already listening

+NETCLOSE: 1 Network is closed for network error

Page 356: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 355

17 SIM Application Toolkit (SAT) Commands

17.1 AT+STIN SAT Indication

Description Every time the SIM Application issues a Proactive Command, via the ME, the TA will receive an indication. This indicates the type of Proactive Command issued. AT+STGI must then be used by the TA to request the parameters of the Proactive Command from the ME. Upon receiving the +STGI response from the ME, the TA must send AT+STGR to confirm the execution of the Proactive Command and provide any required user response, e.g. a selected menu item. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+STIN=? OK

Read Command Responses AT+STIN? +STIN: <cmd_id>

OK

Unsolicited Result Codes

+STIN: <cmd_id> Proactive Command notification

21 – display text 22 – get inkey 23 – get input 24 – select item

+STIN: 25 Notification that SIM Application has returned to main menu. If user does any action in 2 minutes, application will return to main menu automatically. VOICE CALL: BEGIN Notification that SIM Application has originated a voice call.

Defined values

Page 357: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 356

<cmd_id> 21 – display text 22 – get inkey 23 – get input 24 – select item 25 – set up menu

Examples

AT+STIN? +STIN: 24 OK

17.2 AT+STGI Get SAT information

Description Regularly this command is used upon receipt of an URC "+STIN" to request the parameters of the Proactive Command. Then the TA is expected to acknowledge the AT+STGI response with AT+STGR to confirm that the Proactive Command has been executed. AT+STGR will also provide any user information, e.g. a selected menu item. The Proactive Command type value specifies to which "+STIN" the command is related. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+STGI=? OK

Write Command Responses

If <cmd_id>=10: OK

If <cmd_id>=21: +STGI:21,<prio>,<clear_mode>,<text_len>,<text> OK

If <cmd_id>=22: +STGI: 22,< rsp_format>,< help>,<text_len>,<text> OK

AT+STGI=<cmd_id>

If <cmd_id>=23: +STGI:23,<rsp_format>,<max_len>,<min_len>,<help>,<show>,<text_len>,<text> OK

Page 358: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 357

If <cmd_id>=24: +STGI:24,<help>,<softkey>,<present>,<title_len>,<title>,<item_num> +STGI:24,<item_id>,<item_len>,<item_data> […] OK

If <cmd_id>=25: +STGI:25,<help>,<softkey>,<title_len>,<title>,<item_num> +STGI:25,<item_id>,<item_len>,<item_data> [...] OK

Defined values

<cmd_id> 21 – display text 22 – get inkey 23 – get input 24 – select item 25 – set up menu

<prio> Priority of display text

0 – Normal priority 1 – High priority

<clear_mode> 0 – Clear after a delay 1 – Clear by user

<text_len> Length of text

<rsp_format> 0 – SMS default alphabet 1 – YES or NO 2 – numerical only 3 – UCS2

<help> 0 – Help unavailable 1 – Help available

<max_len> Maximum length of input

<min_len> Minimum length of input

<show> 0 – Hide input text

Page 359: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 358

1 – Display input text <softkey>

0 – No softkey preferred 1 – Softkey preferred

<present> Menu presentation format available for select item

0 – Presentation not specified 1 – Data value presentation 2 – Navigation presentation

<title_len> Length of title

<item_num> Number of items in the menu

<item_id> Identifier of item

<item_len> Length of item

<title> Title in ucs2 format

<item_data> Content of the item in ucs2 format

<text> Text in ucs2 format.

Examples

AT+STGI=25 at+stgi=25 +STGI:25,0,0,10,"795E5DDE884C59295730",15 +STGI:25,1,8,"8F7B677E95EE5019" +STGI:25,2,8,"77ED4FE17FA453D1" +STGI:25,3,8,"4F1860E05FEB8BAF" +STGI:25,4,8,"4E1A52A17CBE9009" +STGI:25,5,8,"8D448D3963A88350" +STGI:25,6,8,"81EA52A9670D52A1" +STGI:25,7,8,"8F7B677E5F6994C3" +STGI:25,8,8,"8BED97F367425FD7" +STGI:25,9,10,"97F34E506392884C699C" +STGI:25,10,8,"65B095FB59296C14" +STGI:25,11,8,"94C358F056FE7247" +STGI:25,12,8,"804A59294EA453CB" +STGI:25,13,8,"5F005FC34F1195F2" +STGI:25,14,8,"751F6D3B5E388BC6"

Page 360: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 359

+STGI:25,21,12,"00530049004D53614FE1606F" OK

17.3 AT+STGR SAT respond

Description The TA is expected to acknowledge the AT+STGI response with AT+STGR to confirm that the Proactive Command has been executed. AT+STGR will also provide any user information, e.g. a selected menu item. SIM PIN References

NO Vendor

Syntax

Test Command Responses

AT+STGR=? OK

Write Command Responses

AT+STGR=<cmd_id>[,<data>]

OK

Defined values

<cmd_id> 22 – get inkey 23 – get input 24 – select item 25 – set up menu 83 – session end by user 84 – go backward

<data> If <cmd_id>=22:

Input a character If <cmd_id>=23:

Input a string. If <rsp_format> is YES or NO, input of a character in case of ANSI character set requests one byte, e.g. “Y”. If <rsp_format> is numerical only, input the characters in decimal number, e.g. “123” If <rsp_faomat> is UCS2, requests a 4 byte string, e.g. “0031” <rsp_faomat> refer to the response by AT+STGI=23

If <cmd_id>=24: Input the identifier of the item selected by user

If <cmd_id>=25:

Page 361: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 360

Input the identifier of the item selected by user If <cmd_id>=83:

<data> ignore Note: It could return main menu during Proactive Command id is not 22 or 23

If <cmd_id>= 84: <data> ignore

Examples

AT+STGR=25,1 OK +STIN: 24

17.4 AT+STK STK Switch

Description This command is to disable or enable the STK function. If the argument is 1, it is enabled. While if the argument is 0, it is disabled.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+STK=? +STK: (list of supported <value>s)

OK

Read Command Responses AT+STK? +STK: <value>

OK

Write Command Responses OK AT+STK=<value>

ERROR

Execution Command Responses AT+STK Set default value (<value>=1):

OK

Defined values

<value> 0 – Disable STK

Page 362: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 361

1 – Enable STK

Examples

AT+STK=1 OK

18 Internet Service Command

18.1 Simple mail transfer protocol service

18.1.1 AT+SMTPSRV SMTP server address and port number

Description The synchronous command is used to set SMTP server address and server’s port number. SMTP client will initiate TCP session with the specified server to send an e-mail. If the process of sending an e-mail is ongoing, the command will return “ERROR” directly. Read command returns current SMTP server address and port number. Execution command will clear SMTP server address and set the port number as default value. NOTE After an e-mail is sent successfully or unsuccessfully, SMTP server address and port number won’t be cleared. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+SMTPSRV=? +SMTPSRV: (list of supported <port>s)

OK Read Command Responses AT+SMTPSRV? +SMTPSRV: <server>, <port>

OK Write Command Responses AT+SMTPSRV=<server> [, <port>]

OK

Execution Command Responses AT+SMTPSRV OK

Defined values

Page 363: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 362

<server> SMTP server address, non empty string with double quotes, mandatory and ASCII text string up to 128 characters. <port> Port number of SMTP server in decimal format, from 1 to 65535, and default port is 25 for SMTP.

Examples

AT+SMTPSRV="smtp.server.com",25 OK AT+SMTPSRV? +SMTPSRV: "smtp.server.com", 25 OK AT+SMTPSRV OK AT+SMTPSRV? +SMTPSRV: "", 25 OK

18.1.2 AT+SMTPAUTH SMTP server authentication

Description The synchronous command is used to control SMTP authentication during connection with SMTP server. If SMTP server requires authentication while logging in the server, TE must set the authentication control flag and provide user name and password correctly before sending an e-mail. If the process of sending an e-mail is ongoing, the command will return “ERROR” directly. Read command returns current SMTP server authentication control flag, if the flag is 0, both <user> and <pwd> are empty strings. Execution Command cancels SMTP server authentication and clear user name and password. NOTE After an e-mail is sent successfully or unsuccessfully, server authentication won’t be cleared. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+SMTPAUTH=? +SMTPAUTH: (list of supported <flag>s)

OK

Read Command Responses AT+SMTPAUTH? +SMTPAUTH: <flag>, <user>, <pwd>

OK

Page 364: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 363

Write Command Responses AT+SMTPAUTH= <flag>[, <user>, <pwd>]

OK

Execution Command Responses AT+SMTPAUTH OK

Defined values

<flag> SMTP server authentication control flag, integer type. 0 – SMTP server doesn’t require authentication, factory value.

1 – SMTP server requires authentication. <user> User name to be used for SMTP authentication, non empty string with double quotes and up to 128 characters. <pwd> Password to be used for SMTP authentication, string with double quotes and up to 128 characters. NOTE If <flag> is 0, <user> and <pwd> must be omitted (i.e. only <flag> is present).

Examples

AT+SMTPAUTH? +SMTPAUTH: 0, “”, “” OK AT+SMTPAUTH=1,”username”,”password” OK AT+SMTPAUTH? +SMTPAUTH: 0, ”username”, ”password” OK AT+SMTPAUTH OK AT+SMTPAUTH? +SMTPAUTH: 0, “”, “” OK

18.1.3 AT+SMTPFROM Sender address and name

Description The synchronous command is used to set sender’s address and name, which are used to construct e-mail header. The sender’s address must be correct if the SMTP server requries, and if the process of sending an e-mail is ongoing, the command will return “ERROR” directly. Read command returns current sender’s address and name.

Page 365: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 364

Execution command will clear sender’s address and name. NOTE After an e-mail is sent successfully or unsuccessfully, sender address and name won’t be cleared. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+SMTPFROM=? OK Read Command Responses AT+SMTPFROM? +SMTPFROM: <saddr>, <sname>

OK Write Command Responses AT+SMTPFROM= <saddr>[, <sname>]

OK

Execution Command Responses AT+SMTPFROM OK

Defined values

<saddr> E-mail sender address (MAIL FROM), non empty string with double quotes, mandatory and ASCII text up to 128 characters. <saddr> will be present in the header of the e-mail sent by SMTP client in the field: “From: ”. <sname> E-mail sender name, string with double quotes, and alphanumeric ASCII text up to 64 characters. <sname> will be present in the header of the e-mail sent by SMTP client in the field: “From: ”.

Examples

AT+SMTPFROM="[email protected]","sendername" OK AT+SMTPFROM? +SMTPFROM: "[email protected]", "sendername" OK AT+SMTPFROM OK AT+SMTPFROM? +SMTPFROM: "", "" OK

Page 366: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 365

18.1.4 AT+SMTPRCPT Recipient address and name (TO/CC/BCC)

Description The synchronous command is used to set recipient address/name and kind (TO/CC/BCC). If only the parameter of “kind” is present, the command will clear all recipients of this kind, and if only parameters of “kind” and “index” are present, the command will clear the specified recipient. If the process of sending an e-mail is ongoing, the command will return “ERROR” directly. Read command returns current recipient address/name and kind list. Execution command will clear all recipient information. NOTE After an e-mail is sent successfully, all recipients will be cleared, if unsuccessfully, they won’t be cleared. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+SMTPRCPT=? +SMTPRCPT: (list of supported <kind>s), (list of supported

<index>s) OK

Read Command Responses [+SMTPRCPT: <kind>, <index>, <raddr>, <rname> [<CR><LF>…]] OK

AT+SMTPRCPT?

OK

Write Command Responses AT+SMTPRCPT= <kind>[, <index> [,<raddr>[,<rname>]]]

OK

Execution Command Responses AT+SMTPRCPT OK

Defined values

<kind> Recipient kind, the kinds of TO and CC are used to construct e-mail header in the field: “To: ” or “Cc: ”. 0 – TO, normal recipient.

1 – CC, Carbon Copy recipient. 2 – BCC, Blind Carbon Copy recipient. <index>

Page 367: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 366

Index of the kind of recipient, decimal format, and from 0 to 4. <raddr> Recipient address, non empty string with double quotes, and up to 128 characters. <rname> Recipient name, string type with double quotes, and up to 64 characters.

Examples

AT+SMTPRCPT=0, 0, “[email protected]”, “rcptname_to” OK AT+SMTPRCPT? +SMTPRCPT: 0, 0, “[email protected]”, “rcptname_to” OK AT+SMTPRCPT=1, 0, “[email protected]”, “rcptname_cc” OK AT+SMTPRCPT? +SMTPRCPT: 0, 0, “[email protected]”, “rcptname_to” +SMTPRCPT: 1, 0, “[email protected]”, “rcptname_cc” OK

18.1.5 AT+SMTPSUB E-mail subject

Description The synchronous command is used to set the subject of e-mail, which is used to construct e-mail header. If the process of sending an e-mail is ongoing, the command will return “ERROR” directly. Read command returns current e-mail subject. Execution command will clear the subject. NOTE After an e-mail is sent successfully, the subject will be cleared, if unsuccessfully, it won’t be cleared. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+SMTPSUB=? OK

Read Command Responses AT+SMTPSUB? +SMTPSUB: <subject>

OK

Write Command Responses AT+SMTPSUB=<subject> OK

Execution Command Responses

Page 368: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 367

AT+SMTPSUB OK

Defined values

<subject> E-mail subject, string with double quotes, and ASCII text up to 512 characters. <subject> will be present in the header of the e-mail sent by SMTP client in the field: “Subject: ”. For write command, if the subject contains non-ASCII characters, this parameter should contain a prefix of {non-ascii}.

Examples

AT+SMTPSUB? +SMTPSUB: “” OK AT+SMTPSUB=”THIS IS A TEST MAIL” OK AT+SMTPSUB={non-ascii}”E6B58BE8AF95E982AEE4BBB6” OK AT+SMTPSUB? +SMTPSUB: “THIS IS A TEST MAIL” OK

18.1.6 AT+SMTPBODY E-mail body

Description The command is used to set e-mail body, which will be sent to SMTP server with text format. Read command returns current e-mail body. If the process of sending an e-mail is ongoing, the command will return “ERROR” directly. Execute command will switch the serial port from command mode to data mode, so TE can enter more ASCII text as e-mail body (up to 5120), and CTRL-Z (ESC) is used to finish (cancel) the input operation and switch the serial port back to command mode. NOTE After an e-mail is sent successfully, the body will be cleared, if unsuccessfully, it won’t be cleared. When execute command AT+SMTPBODY, and display “>”, the prevenient body will be cleared. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+SMTPBODY=? OK

Page 369: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 368

Read Command Responses AT+SMTPBODY? +SMTPBODY: <body>

OK

Write Command Responses AT+SMTPBODY=<body> OK

Execution Command Responses AT+SMTPBODY >>

Defined values

<body> E-mail body, string with double quotes, and printable ASCII text up to 512 or 5120 characters. NOTE In data mode, “BACKSPACE” can be used to cancel an ASCII character.

Examples

AT+SMTPBODY=”THIS IS A TEST MAIL FROM SIMCOM MODULE” OK AT+SMTPBODY? +SMTPBODY: ”THIS IS A TEST MAIL FROM SIMCOM MODULE” OK AT+SMTPBODY >> This is a test mail.<CTRL-Z> OK AT+SMTPBODY? +SMTPBODY: ”This is a test mail.” OK AT+SMTPBODY >> This is a test mail.<ESC> OK AT+SMTPBODY? +SMTPBODY: “” OK

18.1.7 AT+SMTPBCH E-mail body character set

Description The synchronous command is used to set the body character set of e-mail. If the process of sending an e-mail is ongoing, the command will return “ERROR” directly. Read command returns current e-mail body character set.

SIM PIN References

Page 370: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 369

YES Vendor

Syntax

Test Command Responses AT+SMTPBCH=? +SMTPSUB: ”CHARSET”

OK

Read Command Responses AT+SMTPBCH? +SMTPSUB: <charset>

OK

Write Command Responses AT+SMTPBCH=<charset> OK

Defined values

<charset> E-mail body character, string with double quotes. By default, it is “utf-8”. The maximum length is 30 bytes.

Examples

AT+SMTPBCH=? +SMTPSUB: “CHARSET” OK AT+SMTPBCH=”gb2312” OK AT+SMTPBCH? +SMTPBCH: “gb2312” OK

18.1.8 AT+SMTPFILE Select attachment

Description The synchronous command is used to select file as e-mail attachment. If the process of sending an e-mail is ongoing, the command will return “ERROR” directly. Read command returns current all selected attachments with full path. Execute command will clear all attachments. NOTE After an e-mail is sent successfully, attachment will be cleared, if unsuccessfully, it won’t be cleared. The same file can’t be selected twice. AT+SMTPFILE=<index> is used to delete the relevant attachments. SIM PIN References

YES Vendor

Page 371: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 370

Syntax

Test Command Responses AT+SMTPFILE=? +SMTPFILE: (list of supported <index>s)

OK

Read Command Responses AT+SMTPFILE? [+SMTPFILE: <index>, <filename>, <filesize>

[<CR><LF>…]] OK

Write Command Responses OK AT+SMTPFILE=

<index>[, <filename>] [+SMTP: OVERSIZE] ERROR

Execution Command Responses AT+SMTPFILE OK

Defined values

<index> Index for attachments, from 1 to 10. According to the sequence of <index>, SMTP client will encode and send all attachments. <filename> String type with double quotes, the name of a file which is under current directory (refer to file system commands). SMTP client doesn’t allow two attachments with the same file name. For write command, if the file name contains non-ASCII characters, this parameter should contain a prefix of {non-ascii}. <filesize> File size in decimal format. The total size of all attachments can’t exceed 10MB.

Examples

AT+SMTPFILE=1,”file1.txt” OK AT+SMTPFILE=1,{non-ascii}”E6B58BE8AF95E99984E4BBB62E6A7067” OK AT+SMTPFILE? +SMTPFILE: 1, “C:/file1.txt” OK AT+SMTPFILE=2,”file2.txt” OK AT+SMTPFILE? +SMTPFILE: 1, “C:/file1.txt” +SMTPFILE: 2, “C:/file2.txt”

Page 372: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 371

OK

18.1.9 AT+SMTPSEND Initiate session and send e-mail

Description The asynchronous command is used to initiate TCP session with SMTP server and send an e-mail after all mandatory parameters have been set correctly. After SMTP client has connected with specified SMTP server and SMTP client receives an indication that indicates SMTP server is working well, the command will return “+SMTP: OK”, but it doesn’t indicate that the e-mail is already sent successfully. After the e-mail is sent and the session is closed, an Unsolicited Result Code (URC) will be returned to TE, “+SMTP: SUCCESS” indicates the e-mail is sent successfully, and other URCs indicate an failed result and the session is closed. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+SMTPSEND=? OK

Read Command Responses AT+SMTPSEND? +SMTPSEND: <ongoing>

OK

Execution Command Responses OK +SMTP: OK +SMTP: <code>

+SMTP: OK +SMTP: <code> OK

AT+SMTPSEND

+SMTP: <code> ERROR

Defined values

<ongoing> Whether or not an e-mail is sent in process. If the process of sending an e-mail is ongoing, SMTP client can’t send the e-mail again.

0 – Not ongoing.

Page 373: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 372

1 – Ongoing. <code> SUCCESS SMTP client has sent the e-mail successfully. ONGOING The process of sending an e-mail is ongoing. PARAM ERROR Mandatory parameter isn’t set (SMTP server, or sender/recipient address) NETWORK ERROR Invalid SMTP server.

Network is bad for establishing session or sending data to SMTP server. SERVER ERROR SMTP server released the session.

SMTP server rejects the operation with wrong response. SMTP server doesn’t give SMTP client a response in time.

AUTH REQUIRED Authentication is required by SMTP server. AUTH ERROR SMTP server rejects the session because of bad user name and password

combination.

Examples

AT+SMTPSEND? +SMTPSEND: 0 OK AT+SMTPSEND +SMTP: OK OK +SMTP: SUCCESS

18.1.10 AT+SMTPSTOP Force to stop sending e-mail

Description The synchronous command is used to force to stop sending e-mail and close the TCP session while sending an e-mail is ongoing. Otherwise, the command will return “ERROR” directly. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+SMTPSTOP=? OK

Execution Command Responses OK AT+SMTPSTOP

ERROR

Examples

Page 374: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 373

AT+SMTPSEND? +SMTPSEND: 1 OK AT+SMTPSTOP OK

18.2 Post Office Protocol 3 Service

18.2.1 AT+POP3SRV POP3 server and account

Description The synchronous command is used to set all parameters to get and e-mail from POP3 server, including server address, port number, user name and password. If POP3 client isn’t free, the command will return “ERROR” directly. Read command returns current all information about POP3 server and account. Execution command will clear POP3 server address, user name and password, and set server’s port number as default value. NOTE After an e-mail is sent successfully or unsuccessfully, POP3 server and account information won’t be cleared. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+POP3SRV=? +POP3SRV: (list of supported <port>s)

OK Read Command Responses AT+POP3SRV? +POP3SRV: <server>, <user>, <pwd>, <port>

OK Write Command Responses AT+POP3SRV=<server>, <user>, <pwd>[, <port>]

OK

Execution Command Responses AT+POP3SRV OK

Defined values

<server> POP3 server address, non empty string with double quotes, mandatory and ASCII text string up to 128 characters.

Page 375: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 374

<user> User name to log in POP3 server, non empty string with double quotes, and up to 128 characters. <pwd> Password to log in POP3 server, string with double quotes, and up to 128 characters. <port> Port number of POP3 server in decimal format, from 1 to 65535, and default port is 110 for POP3.

Examples

AT+POP3SRV=? +POP3SRV: (1-65535) OK AT+POP3SRV? +POP3SRV: “”, “”, “”, 110 OK AT+POP3SRV=”pop3.server.com”, “user_name”, “password”, 110 OK AT+POP3SRV? +POP3SRV: “pop3.server.com”, “user_name”, “password”, 110 OK AT+POP3SRV OK AT+POP3SRV? +POP3SRV: “”, “”, “”, 110 OK

18.2.2 AT+POP3IN Log in POP3 server

Description The asynchronous command is used to log in POP3 server and establish a session after POP3 server and account information are set rightly. If the POP3 client logs in POP3 server successfully, the response “+POP3: SUCCESS” will be returned to TE; if no POP3 operation for a long time after the session is ready, POP3 server may release the session. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+POP3IN=? OK Read Command Responses AT+POP3IN? +POP3IN: “<server>”

Page 376: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 375

OK

+POP3IN: NULL OK

Execute Command

+POP3: SUCCESS OK

OK +POP3: SUCCESS

+POP3: <code> ERROR

AT+POP3IN

ERROR

Defined values

<code> NETWORK ERROR Invalid POP3 server or network is bad for establishing session or

sending data to POP3 server. SERVER ERROR POP3 server released the session.

POP3 server rejects the operation with wrong response. POP3 server doesn’t give POP3 client a response in time.

INVALID UN Invalid user name to log in POP3 server. INVALID UN/PWD Invalid user name and password combination to log in POP3 server. <server> The address of the POP3 server currently logged in.

Examples

AT+POP3IN=? OK AT+POP3IN +POP3: SUCCESS OK

18.2.3 AT+POP3NUM Get e-mail number and total size

Description The asynchronous command is used to get e-mail number and total size on the specified POP3 server after the POP3 client logs in POP3 server successfully and no other POP3 operation is ongoing. SIM PIN References

YES Vendor

Page 377: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 376

Syntax

Test Command Responses AT+POP3NUM=? OK

Execution Command Responses +POP3: <num>, <tsize> OK

AT+POP3NUM

+POP3: <code> ERROR

Defined values

<num> The e-mail number on the POP3 server, decimal format. <tsize> The total size of all e-mail and the unit is in Byte. <code> NETWORK ERROR Network is bad for sending data to POP3 server. SERVER ERROR POP3 server released the session.

POP3 server rejects the operation with wrong response. POP3 server doesn’t give POP3 client a response in time.

Examples

AT+POP3NUM=? OK AT+POP3NUM +POP3: 1, 3057 OK

18.2.4 AT+POP3LIST List e-mail ID and size

Description The asynchronous command is used to list e-mail number and total size, e-mail ID and each e-mail’s size after the POP3 client logs in POP3 server successfully and no other POP3 operation is ongoing. The e-mail ID may be used to do those operations: get e-mail header, get the whole e-mail, and mark an e-mail to delete from POP3 server. SIM PIN References

YES Vendor

Syntax

Test Command Responses

Page 378: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 377

AT+POP3LIST=? OK

Write Command Responses +POP3: <msg_id>, <size> OK

AT+POP3LIST=<msg_id>

ERROR

Execution Command Responses +POP3: [<msg_id> <size> [<CR><LF>…]] OK

+POP3: EMPTY OK

AT+POP3LIST

+POP3: <code> ERROR

Defined values

<msg_id> The e-mail’s ID. <size> The size of e-mail <msg_id>, and the unit is in Byte. <code> NETWORK ERROR Network is bad for sending data to POP3 server. SERVER ERROR POP3 server released the session.

POP3 server rejects the operation with wrong response. POP3 server doesn’t give POP3 client a response in time. POP3 client gives wrong e-mail’s ID.

Examples

AT+POP3LIST=? OK AT+POP3LIST +POP3: 1 3056 OK AT+POP3LIST=1 +POP3: 1, 3056 OK

Page 379: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 378

18.2.5 AT+POP3HDR Get e-mail header

Description The asynchronous command is used to retrieve e-mail’s sender address, date and sender address, that are present in the mail’s header. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+POP3HDR=? OK

Write Command Responses From: [<from>] Date: [<date>] Subject: [<sub>] OK

AT+POP3HDR=<msg_id>

+POP3: <code> ERROR

Defined values

<msg_id> The e-mail’s ID. <from> E-mail’s sender name and sender address from mail <date> E-mail’s date from mail header. <sub> E-mail’s subject from mail header. <code> NETWORK ERROR Network is bad for sending data to POP3 server. SERVER ERROR POP3 server released the session.

POP3 server rejects the operation with wrong response. POP3 server doesn’t give POP3 client a response in time. POP3 client gives wrong e-mail’s ID.

Examples

AT+POP3HDR=1 From: sendername<[email protected]> Date: Mon, 17 Aug 2009 14:09:27 +0800

Page 380: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 379

Subject: THIS IS A TEST MAIL OK

18.2.6 AT+POP3GET Get an e-mail from POP3 server

Description The command is used to retrieve specified e-mail from the POP3 server. After retrieving an e-mail successfully, POP3 client will create a directory and save the e-mail’s header and body into file system as file “EmailYYMMDDHHMMSSXYZ.TXT”, and save each attachment as a file under the same directory. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+POP3GET=? OK

Write Command Responses OK +POP3: <code> <mail_dir>, <mail_file>

AT+POP3GET=<msg_id>,[<get_type>]

+POP3: <code> ERROR

OK +POP3: <code>

Defined values

<msg_id> The e-mail’s ID. <mail_dir> The directory for e-mail and attachment, string type without double quotes and the format is “YYMMDDHHMMSS” which is generated according to module’s RTC. According to the setting of command +FSLOCA (refer to file system commands), TE can select the location (local file system or storage card) in which POP3 client saves e-mail file and attachment. <mail_file> If the <get_type> is 1 or 3, it is the file to save e-mail’s header and body, string type without double quotes. Usually, this file name is “EMAIL110511102353000.TXT”, and if e-mail includes an attachment whose name is the same as the e-mail file, the first twelve digits of the number in the e-mail is generated according to the module’s RTC with format “YYMMDDHHMMSS” and the

Page 381: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 380

last three digits of the number in the e-mail file name will be increase by 1, usually it is “000” for the body file of the email. If the <get_type> is 2, the <mail_file> should be YYMMDDHHMMSS.eml. If the <get_type> is 3, the eml file is not reported. <code> NETWORK ERROR Network is bad for sending or receiving data to POP3 server. SERVER ERROR POP3 server released the session.

POP3 server rejects the operation with wrong response. POP3 server doesn’t give POP3 client a response in time. POP3 client gives wrong e-mail’s ID.

FILE SYSTEM ERROR File system is bad for saving e-mail or attachment or storage card is pulled out. If POP3 client encounters this error, POP3 client will close the session with POP3 server.

SUCCESS POP3 client gets an e-mail from POP3 server successfully. FAILURE POP3 client gets an e-mail unsuccessfully. <get_type> The type to save when getting message from POP3 server:

1 – Save parsed body file and attachments 2 – Save the whole message as a “.eml” file. 3 – Save the parsed body file, attachments and eml file.

Examples

AT+POP3GET=1 OK +POP3: SUCCESS C:/Email/090901120000/, EMAIL11090901120000000.TXT AT+POP3GET=1,2 OK +POP3: SUCCESS C:/Email/090901120000/, 090901120000.eml AT+POP3GET=2 OK +POP3: FAILURE

18.2.7 AT+POP3DEL Mark an e-mail to delete from POP3 server

Description The asynchronous command is used to mark an e-mail to delete from POP3 server. The operation only marks an e-mail on the server to delete it, and after POP3 client logs out POP3 server and closes the session normally, the marked e-mail is deleted on the server. Otherwise, the e-mail isn’t

Page 382: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 381

deleted.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+POP3DEL=? OK

Write Command Responses +POP3: SUCCESS OK

AT+POP3DEL=<msg_id>

+POP3: <code> ERROR

Defined values

<msg_id> E-mail’s ID for mark to delete it on POP3 server. <code> NETWORK ERROR Network is bad for sending data to POP3 server. SERVER ERROR POP3 server released the session.

POP3 server rejects the operation with wrong response. POP3 server doesn’t give POP3 client a response in time. POP3 client gives wrong e-mail’s ID.

Examples

AT+POP3DEL=1 +POP3: SUCCESS OK

18.2.8 AT+POP3OUT Log out POP3 server

Description The command will log out the POP3 server and close the session, and if there are some e-mails which are marked to delete, it also informs POP3 server to delete the marked e-mails. SIM PIN References

YES Vendor

Syntax

Page 383: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 382

Test Command Responses AT+POP3OUT=? OK

Execution Command Responses +POP3: SUCCESS OK

AT+POP3OUT

+POP3: <code> ERROR

ERROR

Defined values

<code> NETWORK ERROR Network is bad for sending data to POP3 server. SERVER ERROR POP3 server released the session.

POP3 server rejects the operation with wrong response. POP3 server doesn’t give POP3 client a response in time. POP3 client gives wrong e-mail’s ID.

Examples

AT+POP3OUT +POP3: SUCCESS OK

18.2.9 AT+POP3STOP Force to stop receiving e-mail/close the session

Description The synchronous command is used to force to close the session, and if the process of receiving e-mail is ongoing, the command also stops the operation. Otherwise, the command will return “ERROR” directly. If an e-mail has been marked to delete, POP3 server won’t delete the e-mail after the session is closed. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+POP3STOP=? OK

Execution Command Responses OK AT+POP3STOP

ERROR

Page 384: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 383

Examples

AT+POP3STOP OK

18.2.10 AT+POP3READ Read an e-mail from file system

Description The command is used to read an e-mail from file system. If the process of receiving e-mail is ongoing, the command can’t read an e-mail. Execution command is used to read the e-mail which is received just now. SIM PIN References

YES Vendor

Syntax Syntax

Test Command Responses AT+POP3READ=? OK

Write Command Responses <e-mail> OK

AT+POP3READ= <location>, <mail_file>

ERROR

Execution Command Responses <e-mail> OK

AT+POP3READ

ERROR

Defined values

<location> The location from which TE reads an e-mail.

0 – Local file system. <mail_file> The e-mail’s file name, string type with double quotes and including a directory name and a text file name separated by the list separator “/”, e.g. “090901103000/EMAIL000.TXT”. <e-mail> The content of e-mail, including e-mail header and body.

Page 385: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 384

18.3 File Transfer Protocol Service

18.3.1 AT+CFTPPORT Set FTP server port

Description The command is used to set FTP server port.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CFTPPORT=? +CFTPPORT: (list of supported <port>s)

OK Read Command Responses AT+CFTPPORT? +CFTPPORT: <port>

OK Write Command Responses

OK AT+CFTPPORT=<port>

+CME ERROR

Defined values

<port> The FTP server port, from 1 to 65535, and default value is 21.

Examples

AT+CFTPPORT=21 OK AT+CFTPPORT? +CFTPPORT:21 OK AT+CFTPPORT=? +CFTPPORT: (1-65535) OK

18.3.2 AT+CFTPMODE Set FTP mode

Description

Page 386: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 385

The command is used to set FTP passive/proactive mode. Default is proactive mode.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CFTPMODE=? +CFTPMODE: (list of supported <mode>s)

OK Read Command Responses AT+CFTPMODE? +CFTPMODE: <mode>

OK Write Command Responses

OK AT+CFTPMODE=<mode>

+CME ERROR

Defined values

<mode> The FTP access mode:

0 – proactive mode. 1 – passive mode.

Examples

AT+CFTPMODE=1 OK AT+CFTPMODE? +CFTPMODE: 1 OK AT+CFTPMODE=? +CFTPMODE: (0,1) OK

18.3.3 AT+CFTPTYPE Set FTP type

Description The command is used to set FTP type. Default is binary type.

SIM PIN References

YES Vendor

Page 387: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 386

Syntax

Test Command Responses AT+CFTPTYPE=? +CFTPTYPE: (list of supported <type>s)

OK Read Command Responses AT+CFTPTYPE? +CFTPTYPE: <type>

OK Write Command Responses

OK AT+CFTPTYPE=<type>

+CME ERROR

Defined values

<type> The FTP type:

I – binary type. A – ASCII type.

Examples

AT+CFTPTYPE=A OK AT+CFTPTYPE? +CFTPTYPE: A OK AT+CFTPTYPE=? +CFTPTYPE: (A,I) OK

18.3.4 AT+CFTPSERV Set FTP server domain name or IP address

Description The command is used to set FTP server domain name or IP address.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CFTPSERV=? +CFTPSERV: “ADDRESS”

OK

Page 388: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 387

Read Command Responses AT+CFTPSERV? +CFTPSERV: ”<address>”

OK Write Command Responses

OK AT+CFTPSERV= ”<address>” +CME ERROR

Defined values

<address> The FTP server domain name or IP address. The maximum length is 100 bytes.

Examples

AT+CFTPSERV=”www.mydomain.com” OK AT+CFTPSERV? +CFTPSERV: “www.mydomain.com” OK AT+CFTPSERV=? +CFTPSERV: ”ADDRESS” OK AT+CFTPSERV=”10.0.0.127” OK

18.3.5 AT+CFTPUN Set user name for FTP access

Description The command is used to set user name for FTP server access. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CFTPUN=? +CFTPUN: “NAME”

OK Read Command Responses AT+CFTPUN? +CFTPUN: “<name>”

OK Write Command Responses AT+CFTPUN=“<name>” OK

Page 389: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 388

+CME ERROR

Defined values

<name> The user name for FTP server access. The maximum length is 30 bytes.

Examples

AT+CFTPUN=”myname” OK AT+CFTPUN=”anonymous” OK AT+CFTPUN? +CFTPUN: “myname” OK AT+CFTPUN=? +CFTPUN: ”NAME” OK

18.3.6 AT+CFTPPW Set user password for FTP access

Description The command is used to set user password for FTP server access.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CFTPPW=? +CFTPPW: “PASSWORD”

OK Read Command Responses AT+CFTPPW? +CFTPPW: “<password>”

OK Write Command Responses

OK AT+CFTPPW=“<password>” +CME ERROR

Defined values

<password>

Page 390: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 389

The user password for FTP server access. The maximum length is 40 bytes.

Examples

AT+CFTPPW=”mypass” OK AT+CFTPPW? +CFTPPW: “mypass” OK AT+CFTPPW=? +CFTPPW: ”mypass” OK

18.3.7 AT+CFTPGETFILE Get a file from FTP server to EFS

Description The command is used to download a file from FTP server to module EFS.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CFTPGETFILE=? +CFTPGETFILE: [{non-ascii}]“FILEPATH”, (list of supported

<dir>s) [, (list of supported <rest_size>s)] OK

Write Command Responses OK +CFTPGETFILE: 0

+CME ERROR

AT+CFTPGETFILE= “<filepath>”,<dir>[,<rest_size>]

OK +CFTPGETFILE: <err>

Defined values

<filepath> The remote file path. When the file path doesn’t contain ”/”, this command transfers file from the current remote FTP directory. If the file path contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii}. <dir> The directory to save the downloaded file (For SIM5320, Only 0 is valid):

0 – current directory [refer to AT+FSCD]

Page 391: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 390

1 – “C:/Picture” directory 2 – “C:/Video” directory 3 – “C:/VideoCall” directory 4 – “D:/Picture” directory 5 – “D:/Video” directory 6 – “D:/VideoCall” directory 7 – “C:/Audio” directory 8 – “D:/Audio” directory

<rest_size> The value for FTP “REST” command which is used for broken transfer when transferring failed last time. It’s range is 0 to 2147483647. <err> The error code of FTP operation.

Examples

AT+CFTPGETFILE=”/pub/mydir/test1.txt”,0 OK … +CFTPGETFILE: 0 AT+CFTPGETFILE=” test2.txt”,0 OK … +CFTPGETFILE: 0 AT+CFTPGETFILE={non-ascii}” B2E2CAD42E747874”,0 OK … +CFTPGETFILE: 0

18.3.8 AT+CFTPPUTFILE Put a file in module EFS to FTP server

Description The command is used to upload a file in the module EFS to FTP server.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CFTPPUTFILE=? +CFTPPPUTFILE: [{non-ascii}] “FILEPATH”, (list of supported

<dir>s)[, (list of supported <rest_size>s)] OK

Page 392: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 391

Write Command Responses OK +CFTPPUTFILE: 0

+CME ERROR

AT+CFTPPUTFILE= “<filepath>”,<dir>[,<rest_size>]

OK +CFTPPUTFILE: <err>

Defined values

<filepath> The remote file path. When the file path doesn’t contain “/”, this command transfers file to the current remote FTP directory. If the file path contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii}. <dir> The directory that contains the file to be uploaded (For SIM5320, Only 0 is valid):

0 – current directory [refer to AT+FSCD] 1 – “C:/Picture” directory 2 – “C:/Video” directory 3 – “C:/VideoCall” directory 4 – “D:/Picture” directory 5 – “D:/Video” directory 6 – “D:/VideoCall” directory 7 – “C:/Audio” directory 8 – “D:/Audio” directory

<rest_size> The value for FTP “REST” command which is used for broken transfer when transferring failed last time. It’s range is 0 to 2147483647. <err> The error code of FTP operation.

Examples

AT+CFTPPUTFILE=”/pub/mydir/test1.txt”,0, 10 OK AT+CFTPPUTFILE=” test2.txt”,0 OK … +CFTPPUTFILE: 0 AT+CFTPPUTFILE={non-ascii}” B2E2CAD42E747874”,0 OK … +CFTPPUTFILE: 0

Page 393: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 392

18.3.9 AT+CFTPGET Get a file from FTP server and output it from SIO

Description The command is used to get a file from FTP server and output it to serial port. This command may have a lot of DATA transferred to DTE using serial port, The AT+CATR command is recommended to be used.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CFTPGET=? +CFTPGET: [{non-ascii}] “FILEPATH” [, (list of supported

<rest_size>s)] OK

Write Command Responses OK +CFTPGET: DATA,<len> … +CFTPGET: DATA, <len> … … +CFTPGET: 0

+CME ERROR

AT+CFTPGET= “<filepath>”[,<rest_size>]

[+CFTPGET: DATA, <len> … +CFTPGET: DATA, <len> … …] +CFTPGET: <err>

Defined values

<filepath> The remote file path. When the file path doesn’t contain ”/”, this command transfer file from the current remote FTP directory. If the file path contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii}. <rest_size> The value for FTP “REST” command which is used for broken transfer when transferring failed last time. It’s range is 0 to 2147483647. <len> The length of FTP data contained in this packet.

Page 394: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 393

<err> The error code of FTP operation.

Examples

AT+CFTPGET=”/pub/mydir/test1.txt”, 10 OK +CFTPGET: DATA, 1020, … +CFTPGET: DATA, 1058, … … +CFTPGET: 0 AT+CFTPGET={non-ascii}”/2F74657374646972/B2E2CAD42E747874” OK +CFTPGET: DATA, 1020, … +CFTPGET: 0 AT+CFTPGETT=? +CFTPGET: [{non-ascii}]“FILEPATH” [,(0-2147483647)] OK

18.3.10 AT+CFTPPUT Put a file to FTP server

Description The command is used to put a file to FTP server using the data got from serial port. Each <Ctrl+Z> character present in the data flow of serial port when downloading FTP data will be coded as <ETX><Ctrl+Z>. Each <ETX> character will be coded as <ETX><ETX>. Single <Ctrl+Z> means end of the FTP data. <ETX> is 0x03, and <Ctrl+Z> is 0x1A. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CFTPPUT=? +CFTPPUT: [{non-ascii}] “FILEPATH” [, (list of supported

<rest_size>s)] OK

Execution Command Responses AT+CFTPPUT=“<filepath>” [,<rest_size>]

+CFTPPUT: BEGIN OK

Page 395: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 394

+CME ERROR

[+CFTPPUPT: BEGIN] +CFTPPUT: <err_code> ERROR

Defined values

<filepath> The remote file path. When the file path doesn’t contain “/”, this command transfers file to the current remote FTP directory. If the file path contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii}. <rest_size> The value for FTP “REST” command which is used for broken transfer when transferring failed last time. It’s range is 0 to 2147483647. <err_code> Refer to “Unsolicited FTP Codes”.

Examples

AT+CFTPPUT=”/pub/mydir/test1.txt”, 20 +CFTPPUT: BEGIN …..<Ctrl+Z> OK AT+CFTPPUT={non-ascii}”/2F74657374646972/B2E2CAD42E747874” +CFTPPUT: BEGIN …..<Ctrl+Z> OK AT+CFTPPUT=? +CFTPPUT: [{non-ascii}]“FILEPATH” [,(0-2147483647)] OK

18.3.11 AT+CFTPLIST List the items in the directory on FTP server

Description This command is used to list the items in the specified directory on FTP server

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CFTPLIST=? +CFTPLIST: [{non-ascii}] “FILEPATH”

Page 396: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 395

OK Write Command Responses

OK [+CFTPLIST: DATA,<len> …] +CFTPLIST:<err>

AT+CFTPLIST=”<dir>”

+CME ERROR

Defined values

<dir> The directory to be listed. If the directory contains non-ASCII characters, the <dir> parameter should contain a prefix of {non-ascii}. <len> The length of data reported <err> The result code of the listing

Examples

AT+CFTPLIST=”/testd” OK +CFTPLIST: DATA,193 drw-rw-rw- 1 user group 0 Sep 1 18:01 . drw-rw-rw- 1 user group 0 Sep 1 18:01 .. -rw-rw-rw- 1 user group 2017 Sep 1 17:24 19800106_000128.jpg +CFTPLIST: 0

18.3.12 Unsolicited FTP Codes (Summary of CME ERROR Codes)

Code of <err> Description 201 Unknown error for FTP 202 FTP task is busy 203 Failed to resolve server address 204 FTP timeout 205 Failed to read file 206 Failed to write file 207 Not allowed in current state 208 Failed to login 209 Failed to logout 210 Failed to transfer data

Page 397: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 396

211 FTP command rejected by server 212 Memory error 213 Invalid parameter 214 Network error

18.4 Hyper Text Transfer Protocol Service

18.4.1 AT+CHTTPACT Launch a HTTP operation

Description The command is used to launch a HTTP operation like GET or POST. Each <Ctrl+Z> character presented in the data flow of serial port will be coded as <ETX><Ctrl+Z>. Each <ETX> character will be coded as <ETX><ETX>. Single <Ctrl+Z> means end of the HTTP request data or end of the HTTP responded data. <ETX> is 0x03, and <Ctrl+Z> is 0x1A. For this command there may be a lot of DATA which need to be transferred to DTE using serial port, it is recommended that the AT+CATR will be used. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CHTTPACT=? +CHTTPACT: “ADDRESS”, (1-65535)

OK Write Command Responses

+CHTTPACT: REQUEST +CHTTPACT: DATA, <len> … +CHTTPACT: DATA, <len> … … +CHTTPACT: 0

+CME ERROR

+CHTTPACT: <err> ERROR

+CHTTPACT: REQUEST +CHTTPACT: <err> ERROR

AT+CHTTPACT= “<address>”,<port>

+CHTTPACT: REQUEST

Page 398: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 397

+CHTTPACT: DATA, <len> … +CHTTPACT: DATA, <len> … … +CHTTPACT: <err> ERROR

Defined values

<address> The HTTP server domain name or IP address. <port> The HTTP server port. <len> The length of HTTP data in the packet. <err> The error code of HTTP operation.

Examples

AT+CHTTPACT=”www.mywebsite.com”,80 +CHTTPACT: REQUEST GET http://www.mywebsite.com/index.html HTTP/1.1 Host: www.mywebsite.com User-Agent: MY WEB AGENT Content-Length: 0 <Ctrl+Z> OK +CHTTPACT: DATA, 249 HTTP/1.1 200 OK Content-Type: text/html Content-Language: zh-CN Content-Length: 57 Date: Tue, 31 Mar 2009 01:56:05 GMT Connection: Close Proxy-Connection: Close <html> <header>test</header> <body> Test body </body>

Page 399: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 398

+CHTTPACT: 0 AT+CHTTPACT=”www.mywebsite.com”,80 +CHTTPACT: REQUEST POST http://www.mywebsite.com/mydir/test.jsp HTTP/1.1 Host: www.mywebsite.com User-Agent: MY WEB AGENT Accept: */* Content-Type: application/x-www-form-urlencoded Cache-Control: no-cache Accept-Charset: utf-8, us-ascii Pragma: no-cache Content-Length: 29 myparam1=test1&myparam2=test2<Ctrl+Z> OK +CHTTPACT: DATA, 234 HTTP/1.1 200 OK Content-Type: text/html Content-Language: zh-CN Content-Length: 54 Date: Tue, 31 Mar 2009 01:56:05 GMT Connection: Close Proxy-Connection: Close <html> <header>result</header> <body> Result is OK </body> +CHTTPACT: 0 AT+CHTTPACT=? +CHTTPACT: “ADDRESS”,(1-65535) OK

18.4.2 Unsolicited HTTP codes (summary of CME ERROR codes)

Code of <err> Description 220 Unknown error for HTTP 221 HTTP task is busy 222 Failed to resolve server address 223 HTTP timeout 224 Failed to transfer data

Page 400: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 399

225 Memory error 226 Invalid parameter 227 Network error

18.5 Secure Hyper Text Transfer Protocol Service

18.5.1 AT+CHTTPSSTART Acquire HTTPS protocol stack

Description This command is used to acquire HTTPS protocol stack.

SIM PIN References

YES Vendor

Syntax

Execute Command Responses

OK AT+CHTTPSSTART ERROR

Examples

AT+CHTTPSSTART OK

18.5.2 AT+CHTTPSSTOP Release HTTPS protocol stack

Description This command is used to release HTTPS protocol stack.

SIM PIN References

YES Vendor

Syntax

Execute Command Responses

OK AT+CHTTPSSTOP ERROR

Examples

Page 401: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 400

AT+CHTTPSSTOP OK

18.5.3 AT+CHTTPSOPSE Open HTTPS session

Description This command is used to open a new HTTPS session. Every time, the module must call AT+CHTTPSSTART before calling AT+CHTTPSOPSE. SIM PIN References

YES Vendor

Syntax

Write Command Responses

OK AT+CHTTPSOPSE=”<host>”,<port> ERROR

Defined values

<host> The host address <port> The host listening port for SSL

Examples

AT+CHTTPSOPSE=”www.mywebsite.com”,443 OK

18.5.4 AT+CHTTPSCLSE Close HTTPS session

Description This command is used to close the opened HTTPS session.

SIM PIN References

YES Vendor

Syntax

Execute Command Responses

OK AT+CHTTPSCLSE ERROR

Page 402: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 401

Examples

AT+CHTTPSCLSE OK

18.5.5 AT+CHTTPSSEND Send HTTPS request

Description This command is used to send HTTPS request. The AT+CHTTPSSEND=<len> is used to download the data to be sent. The AT+CHTTPSSEND is used to wait the result of sending. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CHTTPSSEND=? +CHTTPSSEND: (1-4096)

OK Read Command Responses AT+CHTTPSSEND? +CHTTPSSEND: <unsent_len>

OK Write Command Responses

> OK

AT+ CHTTPSSEND =<len>

ERROR Execute Command Responses

OK +CHTTPSSEND: <result>

AT+CHTTPSSEND

ERROR

Defined values

<unsent_len> The length of the data in the sending buffer which is waiting to be sent. <len> The length of the data to send <result> The final result of the sending. 0 – ok 1 – unknown error 2 – busy 3 – server closed

Page 403: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 402

4 – timeout 5 – transfer failed 6 – memory error 7 – invalid parameter 8 – network error

Examples

AT+CHTTPSSEND=88 >GET / HTTP/1.1 Host: www.mywebsite.com User-Agent: MY WEB AGENT Content-Length: 0 OK AT+CHTTPSSEND OK +CHTTPSSEND: 0 AT+CHTTPSSEND? +CHTTPSSEND: 88 OK

18.5.6 AT+CHTTPSRECV Receive HTTPS response

Description This command is used to receive HTTPS response after sending HTTPS request.

SIM PIN References

YES Vendor

Syntax

Write Command Responses

OK +CHTTPSRECV: DATA,<len> … +CHTTPSRECV: DATA,<len> … +CHTTPSRECV:<result> +CHTTPSRECV:<result> ERROR

AT+CHTTPSRECV=<recv_len>

ERROR

Page 404: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 403

Defined values

<recv_len> The minimum length of the data to be received. The final length of the received data may be larger than the requested length.The maximum length is 4096. <len> The length of the data received. <result> The final result of the receiving. 0 – ok 1 – unknown error 2 – busy 3 – server closed 4 – timeout 5 – transfer failed 6 – memory error 7 – invalid parameter 8 – network error

Examples

AT+CHTTPSRECV=1 OK +CHTTPSRECV: DATA,249 HTTP/1.1 200 OK Content-Type: text/html Content-Language: zh-CN Content-Length: 57 Date: Tue, 31 Mar 2009 01:56:05 GMT Connection: Close Proxy-Connection: Close <html> <header>test</header> <body> Test body </body> +CHTTPSRECV: 0

18.5.7 Unsolicited HTTPS Codes

Code of <err> Description

Page 405: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 404

+CHTTPS: RECV EVENT When the AT+CHTTPSRECV is not being called, and there is data cached in the receiving buffer, this event will be reported.

18.6 Secure File Transfer Protocol Service

The FTPS related AT commands needs the AT+CATR to be set to the used port. AT+CATR=0 may cause some problem.

18.6.1 AT+CFTPSSTART Acquire FTPS protocol stack

Description This command is used to acquire FTPS protocol stack.

SIM PIN References

YES Vendor

Syntax

Execute Command Responses

OK AT+CFTPSSTART ERROR

Examples

AT+CFTPSSTART OK

18.6.2 AT+CFTPSSTOP Stop FTPS protocol stack

Description This command is used to stop FTPS protocol stack. Currently only explicit FTPS mode is supported. SIM PIN References

YES Vendor

Syntax

Execute Command Responses

OK AT+CFTPSSTOP ERROR

Page 406: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 405

Examples

AT+CFTPSSTOP OK

18.6.3 AT+CFTPSLOGIN Login the FTPS server

Description This command is used to login the FTPS server. Each time, the module must call AT+CFTPSSTART before calling AT+CFTPSLOGIN. SIM PIN References

YES Vendor

Syntax

Write Command Responses

OK AT+CFTPSLOGIN=”<host>”,<port>,”<username>”, ”<password>”

ERROR

Defined values

<host> The host address, maximum length is 256 <port> The host listening port for SSL, the range is from 1 to 65535 <username> The user name, maximum length is 256 <password> The password, maximum length is 256

Examples

AT+CFTPSLOGIN=”www.myftpsserver.com”,990, ”myname”, ”mypassword” OK

18.6.4 AT+CFTPSLOGOUT Logout the FTPS server

Description This command is used to logout the FTPS server.

Syntax

Page 407: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 406

Execute Command Responses

OK AT+CFTPSLOGOUT ERROR

Examples

AT+CFTPSLOGOUT OK

18.6.5 AT+CFTPSMKD Create a new directory on FTPS server

Description This command is used to create a new directory on the FTPS server. The maximum length of the full path name is 256. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CFTPSMKD=? +CFTPSMKD: ”DIR”

OK Write Command Responses

OK AT+CFTPSMKD=”<dir>”

ERROR

Defined values

<dir> The directory to be created

Examples

AT+CFTPSMKD=”testdir” OK AT+CFTPSMKD={non-ascii}”74657374646972” OK

18.6.6 AT+CFTPSRMD Delete a directory on FTPS server

Description

Page 408: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 407

This command is used to delete a directory on FTPS server

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CFTPSRMD=? +CFTPSRMD: ”DIR”

OK Write Command Responses

OK AT+CFTPSRMD=”<dir>”

ERROR

Defined values

<dir> The directory to be removed. If the directory contains non-ASCII characters, the <dir> parameter should contain a prefix of {non-ascii}.

Examples

AT+CFTPSRMD=”testdir” OK AT+CFTPSRMD={non-ascii}”74657374646972” OK

18.6.7 AT+CFTPSDELE Delete a file on FTPS server

Description This command is used to delete a file on FTPS server

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CFTPSDELE=? +CFTPSDELE: ”FILENAME”

OK Write Command Responses

OK AT+CFTPSDELE=”<filename>” ERROR

Page 409: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 408

Defined values

<filename> The name of the file to be deleted. If the file name contains non-ASCII characters, the <filename> parameter should contain a prefix of {non-ascii}.

Examples

AT+CFTPSDELE=”test” OK AT+CFTPDELE={non-ascii}”74657374” OK

18.6.8 AT+CFTPSCWD Change the current directory on FTPS server

Description This command is used to change the current directory on FTPS server

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CFTPSCWD=? +CFTPSCWD: ”DIR”

OK Write Command Responses

OK AT+CFTPSCWD=”<dir>”

ERROR

Defined values

<dir> The directory to be changed. If the directory contains non-ASCII characters, the <dir> parameter should contain a prefix of {non-ascii}.

Examples

AT+CFTPSCWD=”testdir” OK AT+CFTPSCWD={non-ascii}”74657374646972” OK

Page 410: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 409

18.6.9 AT+CFTPSPWD Get the current directory on FTPS server

Description This command is used to get the current directory on FTPS server.

SIM PIN References

YES Vendor

Syntax

Execute Command Responses

+CFTPSPWD: ”<dir>” OK

AT+CFTPSPWD

ERROR

Defined values

<dir> The current directory on FTPS server.

Examples

AT+CFTPSPWD +CFTPSPWD: “/testdir” OK

18.6.10 AT+CFTPSTYPE Set the transfer type on FTPS server

Description This command is used to set the transfer type on FTPS server

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CFTPSTYPE=? +CFTPSTYPE: (A,I)

OK Read Command Responses AT+CFTPSTYPE? +CFTPSTYPE: <type>

OK Write Command Responses

Page 411: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 410

OK AT+CFTPSTYPE=<type>

ERROR

Defined values

<type> The type of transferring:

A – ASCII. I – Binary.

Examples

AT+CFTPSTYPE=A OK

18.6.11 AT+CFTPSLIST List the items in the directory on FTPS server

Description This command is used to list the items in the specified directory on FTPS server

SIM PIN References

YES Vendor

Syntax

Write Command Responses OK +CFTPSLIST: DATA,<len> … +CFTPSLIST:<err>

AT+CFTPSLIST=”<dir>”

ERROR Execute Command Responses

OK +CFTPSLIST: DATA,<len> … +CFTPSLIST:<err> OK +CFTPSLIST:<err> +CFTPSLIST:<err> ERROR

AT+CFTPSLIST

ERROR

Page 412: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 411

Defined values

<dir> The directory to be listed. If the directory contains non-ASCII characters, the <dir> parameter should contain a prefix of {non-ascii}. <len> The length of data reported <err> The result code of the listing

Examples

AT+CFTPSLIST=”/testd” OK +CFTPSLIST: DATA,193 drw-rw-rw- 1 user group 0 Sep 1 18:01 . drw-rw-rw- 1 user group 0 Sep 1 18:01 .. -rw-rw-rw- 1 user group 2017 Sep 1 17:24 19800106_000128.jpg +CFTPSLIST: 0 AT+CFTPSLIST OK +CFTPSLIST: DATA,193 drw-rw-rw- 1 user group 0 Sep 1 18:01 . drw-rw-rw- 1 user group 0 Sep 1 18:01 .. -rw-rw-rw- 1 user group 2017 Sep 1 17:24 19800106_000128.jpg +CFTPSLIST: 0

18.6.12 AT+CFTPSGETFILE Get a file from FTPS server to EFS

Description The command is used to download a file from FTPS server to module EFS.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CFTPSGETFILE=? +CFTPSGETFILE: [{non-ascii}]“FILEPATH”, (list of supported

<filepath>s) OK

Write Command Responses

Page 413: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 412

OK +CFTPSGETFILE: 0

+CFTPSGETFILE: <err> ERROR

ERROR

AT+CFTPGETFILE= “<filepath>”,<dir>

OK +CFTPSGETFILE: <err>

Defined values

<filepath> The remote file path. When the file path doesn’t contain ”/”, this command transfers file from the current remote FTPS directory. If the file path contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii}. <dir> The directory to save the downloaded file:

0 – current directory [refer to AT+FSCD] <err> The error code of FTPS operation.

Examples

AT+CFTPSGETFILE=”/pub/mydir/test1.txt”,1 OK … +CFTPSGETFILE: 0 AT+CFTPSGETFILE=” test2.txt”,2 OK … +CFTPSGETFILE: 0 AT+CFTPSGETFILE={non-ascii}” B2E2CAD42E747874”,2 OK … +CFTPSGETFILE: 0 AT+CFTSPGETFILE=? +CFTPSGETFILE: [{non-ascii}]“FILEPATH”,(0) OK

18.6.13 AT+CFTPSPUTFILE Put a file in module EFS to FTPS server

Description The command is used to upload a file in the module EFS to FTPS server.

Page 414: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 413

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CFTPSPUTFILE=? +CFTPSPUTFILE: [{non-ascii}] “FILEPATH”, (list of supported

<filepath>s) OK

Write Command Responses OK +CFTPSPUTFILE: 0

+CFTPSPUTFILE: <err> ERROR

ERROR

AT+CFTPSPUTFILE= “<filepath>”,<dir>

OK +CFTPSPUTFILE: <err>

Defined values

<filepath> The remote file path. When the file path doesn’t contain “/”, this command transfers file to the current remote FTPS directory. If the file path contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii}. <dir> The directory that contains the file to be uploaded:

0 – current directory [refer to AT+FSCD] <err> The error code of FTPS operation.

Examples

AT+CFTPSPUTFILE=”/pub/mydir/test1.txt”,1 OK AT+CFTPSPUTFILE=” test2.txt”,1 OK … +CFTPSPUTFILE: 0 AT+CFTPSPUTFILE={non-ascii}” B2E2CAD42E747874”,1 OK … +CFTPSPUTFILE: 0 AT+CFTPSPUTFILE=?

Page 415: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 414

+CFTPSPUTFILE: [{non-ascii}]“FILEPATH”,(0) OK

18.6.14 AT+CFTPSGET Get a file from FTPS server to serial port

Description The command is used to get a file from FTPS server and output it to serial port. This command may have a lot of DATA transferred to DTE using serial port, The AT+CATR command is recommended to be used.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CFTPSGET=? +CFTPSGET: [{non-ascii}] “FILEPATH”

OK Write Command Responses

OK +CFTPSGET: DATA,<len> … +CFTPSGET: DATA, <len> … … +CFTPSGET: 0

+CFTPSGET: <err> ERROR

ERROR

AT+CFTPSGET= “<filepath>”

+CFTPSGET: DATA, <len> … +CFTPSGET: DATA, <len> … … +CFTPSGET: <err>

Defined values

<filepath> The remote file path. When the file path doesn’t contain ”/”, this command transfer file from the current remote FTPS directory. If the file path contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii}. <len>

Page 416: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 415

The length of FTPS data contained in this packet. <err> The error code of FTPS operation.

Examples

AT+CFTPSGET=”/pub/mydir/test1.txt” OK +CFTPSGET: DATA, 1020, … +CFTPSGET: DATA, 1058, … … +CFTPSGET: 0 AT+CFTPSGET={non-ascii}”/2F74657374646972/B2E2CAD42E747874” OK +CFTPSGET: DATA, 1020, … +CFTPSGET: 0 AT+CFTPSGET=? +CFTPSGET:[{non-ascii}] “FILEPATH” OK

18.6.15 AT+CFTPSPUT Put a file to FTPS server

Description This command is used to put a file to FTPS server through serial port. The AT+CFTPSPUT= [“<filepath>”,]<len> is used to download the data to be sent. The AT+CFTPSPUT is used to wait the result of sending. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CFTPSPUT=? +CFTPSPUT: [{non-ascii}]"FILEPATH"

OK

Read Command Responses AT+CFTPSPUT? +CFTPSPUT: <unsent_len>

OK Write Command Responses AT+CFTPSPUT=[“<filepath >

Page 417: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 416

OK

+CFTPSPUT: <result> ERROR

>”,]<len>

ERROR Execute Command Responses

OK +CFTPSPUT: <result>

AT+CFTPSPUT

ERROR

Defined values

<filepath> The path of the file on FTPS server. <unsent_len> The length of the data in the sending buffer which is waiting to be sent. <len> The length of the data to send, the maximum length is 512. <result> The final result of the sending.

Examples

AT+CFTPSPUT=”t1.txt”,10 >testcontent OK AT+CFTPSPUT OK +CFTPSSPUT: 0 AT+CFTPSPUT? +CFTPSPUT: 88 OK

18.6.16 AT+CFTPSSINGLEIP Set FTPS data socket address type

Description The command is used to set FTPS server data socket IP address type

SIM PIN References

YES Vendor

Syntax

Page 418: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 417

Test Command Responses AT+CFTPSSINGLEIP=? +CFTPSSINGLEIP: (0,1)

OK Read Command Responses AT+CFTPSSINGLEIP? + CFTPSSINGLEIP: <singleip>

OK Write Command Responses

OK AT+CFTPSSINGLEIP=<singleip> ERROR

Defined values

<singleip> The FTPS data socket IP address type: 0 – decided by PORT response from FTPS server

1 – the same as the control socket.

Examples

AT+CFTPSSINGLEIP=1 OK AT+CFTPSSINGLEIP? +CFTPSSINGLEIP:1 OK AT+CFTPSSINGLEIP=? +CFTPSSINGLEIP: (0,1) OK

18.6.17 Unsolicited FTPS Codes

Code of <err> Description 0 FTPS operation succeeded 1 SSL verify alert 2 Unknown FTPS error 3 FTPS busy 4 FTPS server closed connection 5 Timeout 6 FTPS transfer failed 7 FTPS memory error 8 Invalid parameter 9 Operation rejected by FTPS server 10 Network error

Page 419: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 418

18.7 HTTP Time Synchronization Service

The HTP related AT commands are used to synchronize system time with HTP server.

18.7.1 AT+CHTPSERV Set HTP server info

Description The command is used to add or delete HTP server information. There are maximum 16 HTP servers. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CHTPSERV=? +CHTPSERV:"ADD","HOST",(1-65535),

(0-1)[,"PROXY",(1-65535)] +CHTPSERV: "DEL",(0-15) OK

Read Command Responses +CHTPSERV:<index>"<host>",<port>,<http_version> [,"<proxy>",<proxy_port>] … +CHTPSERV:<index>"<host>",<port>[,"<proxy>",< proxy_port>]OK

AT+CHTPSERV?

OK (if HTP server not setted)

Write Command Responses OK AT+CHTPSERV=

"<cmd>","<host_or_idx>"[,<port>,<http_version> [,"<proxy>",<proxy_port>]]

ERROR

Defined values

<cmd> The command to operate the HTP server list. “ADD”: add a HTP server item to the list “DEL”: delete a HTP server item from the list <host_or_idx> If the <cmd> is “ADD”, this field is the same as <host>, needs quotation marks; If the <cmd> is “DEL”, this field is the index of the HTP server item to be deleted from the list, does not need

Page 420: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 419

quotation marks. <host> The HTP server address. <port> The HTP server port. <http_version> The HTTP version of the HTP server:

0- HTTP 1.0 1- HTTP 1.1

<proxy> The proxy address <proxy_port> The port of the proxy <index> The HTP server index.

Examples

AT+CHTPSERV=”ADD”,”www.google.com”,80,1 OK

18.7.2 AT+CHTPUPDATE Updating date time using HTP protocol

Description The command is used to updating date time using HTP protocol.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CHTPUPDATE=? OK Read Command Response AT+CHTPUPDATE? +CHTPUPDATE:<status>

OK

Execute Command Responses OK +CHTPUPDATE: <err>

AT+CHTPUPDATE

ERROR

Defined values

Page 421: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 420

<status> The status of HTP module: Updating: HTP module is synchronizing date time NULL: HTP module is idle now <err> The result of the HTP updating

Examples

AT+CHTPUPDATE OK +CHTPUPDATE: 0

18.7.3 Unsolicited HTP Codes

Code of <err> Description 0 Operation succeeded 1 Unknown error 2 Wrong parameter 3 Wrong date and time calculated 4 Network error

Page 422: Simcom Sim5320 Atc en v1.23

19 MMS Commands

The maximum of recipients, copy-to recipients, and secret recipients are respective 20. The maximum length of recipients’ number is 60.

19.1 AT+CMMSCURL Set the URL of MMS center

Description The command is used to set the URL of MMS center.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSCURL=? +CMMSCURL:”URL”

OK

Read Command Responses AT+CMMSCURL? +CMMSCURL: “<mmscurl>”

OK

Write Command Responses OK ERROR

AT+CMMSCURL=”<mmscurl>”

+CME ERROR: <err>

Defined values

<mmscurl> The URI of MMS center, not including “http://”

Examples

AT+CMMSCURL=” mmsc.monternet.com” OK AT+CMMSCURL? +CMMSCURL:” mmsc.monternet.com” OK AT+CMMSCURL=? +CMMSCURL:”URL”

Page 423: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 422

OK

19.2 AT+CMMSPROTO Set the protocol parameters and MMS proxy

Description The command is used to set the protocol parameters and MMS proxy address.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSPROTO=? +CMMSPROTO:

(0,1),”(0-255).(0-255).(0-255).(0-255)”,(0-65535) OK

Read Command Responses AT+CMMSPROTO? +CMMSPROTO: <type>,<gateway>,<port>

OK

Write Command Responses OK ERROR

AT+CMMSPROTO=<type>[,<gateway>,<port>]

+CME ERROR: <err>

Defined values

<type> The application protocol for MMS:

0 – WAP 1 – HTTP

<gateway> IP address of MMS proxy <port> Port of MMS proxy

Examples

AT+CMMSPROTO=0,”10.0.0.172”,9201 OK AT+CCMMSPROTO? +CMMSPROTO: 0,”10.0.0.172”,9201 OK AT+CMMSPROTO=?

Page 424: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 423

+CMMSPROTO: (0,1),”(0-255).(0-255).(0-255).(0-255)”,(0-65535) OK

19.3 AT+CMMSSENDCFG Set the parameters for sending MMS

Description The command is used to set the parameters for sending MMS.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSSENDCFG=? +CMMSSENDCFG: (0-6),(0-3),(0,1),(0,1),(0-2),(0-4)

OK

Read Command Responses AT+CMMSSENDCFG? +CMMSSENDCFG:

<valid>,<pri>,<sendrep>,<readrep>,<visible>,<class> OK

Write Command Responses OK ERROR

AT+CMMSSENDCFG=<valid>,<pri>,<sendrep>,<readrep>,<visible>,<class> +CME ERROR: <err>

Defined values

<valid> The valid time of the sent MMS:

0 – 1 hour. 1 – 12 hours. 2 – 24 hour. 3 – 2 days. 4 – 1 week. 5 – maximum. 6 – Not set (default).

<pri> Priority:

0 – lowest. 1 – normal. 2 – highest. 3 – Not set (default)

<sendrep>

Page 425: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 424

Whether need delivery report: 0 – No (default). 1 – Yes.

<readrep> Whether need read report:

0 – No (default). 1 – Yes.

<visible> Whether to show the address of the sender:

0 – hide the address of the sender. 1 – Show the address of the sender even if it is a secret address. 2 – Not set (default).

<class> The class of MMS:

0 – personal. 1 – advertisement. 2 – informational. 3 – auto. 4 – Not set (default).

Examples

AT+CMMSSENDCFG=6,3,1,1,2,4 OK AT+CMMSSENDCFG? +CMMSSENDCFG:6,3,1,1,2,4 OK AT+CMMSSENDCFG=? +CMMSSENDCFG: (0-6),(0-3),(0,1),(0,1),(0-2),(0-4) OK

19.4 AT+CMMSEDIT Enter or exit edit mode

Description The command is used to enter or exit edit mode of mms.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSEDIT=? +CMMSEDIT: (0,1)

Page 426: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 425

OK

Read Command Responses AT+CMMSEDIT? +CMMSEDIT: <mode>

OK

Write Command Responses OK ERROR

AT+CMMSEDIT=<mode>

+CME ERROR: <err>

Defined values

<mode> Whether to allow edit MMS:

0 – No. 1 – Yes.

Examples

AT+CMMSEDIT=0 OK AT+CMMSEDIT? +CMMSEDIT:0 OK AT+CMMSEDIT=? +CMMSEDIT:(0-1) OK

19.5 AT+CMMSDOWN Download the file data or title from UART

Description This command is used to download file data to MMS body. When downloading a text file or title from UART, the text file or title must start with \xFF\xFE , \xFE\xFF or \xEF\xBB\xBF to indicate whether it is UCS2 little endian, UCS2 big endian or UTF-8 format. Without these OCTETS, the text file or title will be regarded as UTF-8 format.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSDOWN=? +CMMSDOWN: “PIC”,(1-<max_pdu_size>),”NAME”

Page 427: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 426

+CMMSDOWN: “TEXT”,(1-<max_pdu_size>),”NAME” +CMMSDOWN: “AUDIO”,(1-<max_pdu_size>),”NAME” +CMMSDOWN: “VIDEO”,(1-<max_pdu_size>),”NAME” +CMMSDOWN: “SDP”,(1-<max_pdu_size>) +CMMSDOWN: “FILE”,(0-8),”FILENAME” +CMMSDOWN: “TITLE”,(1-40) OK

Write Command Responses OK

ERROR

AT+CMMSDOWN=<type>,<size>[,<name>] Or AT+CMMSDOWN=<type>,<dir>,<filename>

+CME ERROR: <err>

Defined values

<type> The type of file to download:

“PIC” – JPG/GIF/PNG/TIFF file. “TEXT" – plain text file. “AUDIO” – MIDI/WAV/AMR/MPEG file. “VIDEO” – 3GPP/MP4 file. “SDP” – application/sdp type “FILE" – file in the UE. “TITLE" – subject of the MMS.

<size> The size of file data need to download through AT interface. <name> The name of the file to download. <dir> The directory of the selected file:

0 – current directory[[refer to AT+FSCD]

1 – “C:/Picture” directory

2 – “C:/Video” directory

3 – “C:/VideoCall” directory

4 – “D:/Picture” directory

5 – “D:/Video” directory

6 – “D:/VideoCall” directory

7 – “C:/Audio” directory

8 – “D:/Audio” directory <filename> The name of the file existing in the UE to download. <max_pdu_size>

Page 428: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 427

The maximum size of MMS PDU permitted.

Examples

AT+CMMSDOWN=? +CMMSDOWN: “PIC”,(1-102400),”NAME” +CMMSDOWN: “TEXT”,(1-102400),”NAME” +CMMSDOWN: “AUDIO”,(1-102400),”NAME” +CMMSDOWN: “VIDEO”,(1-102400),”NAME” +CMMSDOWN:"SDP",(1-102400) +CMMSDOWN: “FILE”,(0-8),”FILEPATH” +CMMSDOWN: “TITLE”,(1-40) OK AT+CMMSDOWN=”PIC”,20112,”test1.jpg” <CR><LF> >….(20112 bytes of data transferred in AT interface) OK AT+CMMSDOWN="FILE",2,” test2.wav” OK

19.6 AT+CMMSDELFILE Delete a file within the editing MMS body

Description This command is used to delete a file within the editing MMS body.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSDELFILE=? OK

Write Command Responses OK

ERROR

AT+CMMSDELFILE=<index>

+CME ERROR: <err>

Defined values

Page 429: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 428

<index> The index of the file to delete contains in the MMS body.

Examples

AT+CMMSDELFILE=2 OK AT+CMMSDELFILE=? OK

19.7 AT+CMMSSEND Start MMS sending

Description This command is used to send MMS. It can only be performed in edit mode of MMS.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSSEND=? +CMMSSEND=”ADDRESS”

OK Write Command Responses

OK +CMMSSEND:0 ERROR

AT+CMMSSEND=<address>

+CME ERROR: <err> Or OK +CMMSSEND :<err>

Execute Command Responses

OK +CMMSSEND:0 ERROR

AT+CMMSSEND

+CME ERROR: <err> Or OK

Page 430: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 429

+CMMSSEND :<err>

Defined values

<address> Mobile phone number or email address. As mobile phone number, the max length is 40; As email address, the max length is 60;

Examples

AT+CMMSSEND=”13613623116” OK +CMMSSEND:0 AT+CMMSSEND OK +CMMSSEND:0 AT+CMMSSEND=” 13613623116” OK +CME ERROR: 190 AT+CMMSSEND=2,”13613623116” +CME ERROR: 177

19.8 AT+CMMSRECP Add recipients

Description This command is used to add recipients.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSRECP=? +CMMSRECP: ”ADDRESS ”

OK

Read Command Responses +CMMSRECP: (list of <addr>s) OK ERROR

AT+CMMSRECP?

+CME ERROR: <err>

Page 431: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 430

Write Command Responses OK ERROR

AT+CMMSRECP=<addr>

+CME ERROR: <err>

Defined values

<addr> Mobile phone number or email address. As mobile phone number, the max length is 40; As email address, the max length is 60;

Examples

AT+CMMSRECP=? +CMMSRECP: "ADDRESS" OK AT+CMMSRECP? +CMMSRECP:"[email protected]”;”15813862534” OK AT+CMMSRECP=”13818362596" OK

19.9 AT+CMMSCC Add copy-to recipients

Description This command is used to add copy-to recipients.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSCC=? +CMMSCC: ”ADDRESS ”

OK

Read Command Responses +CMMSCC: (list of <addr>s) OK ERROR

AT+CMMSCC?

+CME ERROR: <err>

Page 432: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 431

Write Command Responses OK ERROR

AT+CMMSCC=<addr>

+CME ERROR: <err>

Defined values

<addr> Mobile phone number or email address。 As mobile phone number, the max length is 40; As email address, the max length is 60;

Examples

AT+CMMSCC=? +CMMSCC: "ADDRESS" OK AT+CMMSCC? +CMMSCC:"[email protected]”;”15813862534” OK AT+CMMSCC=”13818362596" OK

19.10 AT+CMMSBCC Add secret recipients

Description This command is used to add secret recipients.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSBCC=? +CMMSBCC: ”ADDRESS ”

OK

Read Command Responses +CMMSBCC: (list of <addr>s) OK ERROR

AT+CMMSBCC?

+CME ERROR: <err>

Page 433: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 432

Write Command Responses OK ERROR

AT+CMMSBCC=<addr>

+CME ERROR: <err>

Defined values

<addr> Mobile phone number or email address. As mobile phone number, the max length is 40; As email address, the max length is 60;

Examples

AT+CMMSBCC=? +CMMSBCC: "ADDRESS" OK AT+CMMSBCC? +CMMSBCC:"[email protected]”;”15813862534” OK AT+CMMSBCC=”13818362596" OK

19.11 AT+CMMSDELRECP Delete recipients

Description This command is used to delete recipients. The execute command is used to delete all recipients

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSDELRECP=? +CMMSDELRECP: ”ADDRESS ”

OK

Write Command Responses OK ERROR

AT+CMMSDELRECP=<addr>

+CME ERROR: <err>

Execute Command Responses

Page 434: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 433

OK ERROR

AT+CMMSDELRECP

+CME ERROR: <err>

Defined values

<addr> Mobile phone number or email address. As mobile phone number, the max length is 40; As email address, the max length is 60;

Examples

AT+CMMSDELRECP=? +CMMSDELRECP: "ADDRESS" OK AT+CMMSDELRECP OK AT+CMMSDELRECP=”13818362596" OK

19.12 AT+CMMSDELCC Delete copy-to recipients

Description This command is used to delete copy-to recipients. The execution command is used to delete all copy recipients

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSDELCC=? +CMMSDELCC: ”ADDRESS ”

OK

Write Command Responses OK ERROR

AT+CMMSDELCC=<addr>

+CME ERROR: <err>

Execute Command Responses OK ERROR

AT+CMMSDELCC

+CME ERROR: <err>

Page 435: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 434

Defined values

<addr> Mobile phone number or email address. As mobile phone number, the max length is 40; As email address, the max length is 60;

Examples

AT+CMMSDELCC=? +CMMSDELCC: "ADDRESS" OK AT+CMMSDELCC OK AT+CMMSDELCC=”13818362596" OK

19.13 AT+CMMSDELBCC Delete secret recipients

Description This command is used to delete secret recipients. The execution command is used to delete all secret recipients

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSDELBCC=? +CMMSDELBCC: ”ADDRESS ”

OK

Write Command Responses OK ERROR

AT+CMMSDELBCC=<addr>

+CME ERROR: <err>

Execute Command Responses OK ERROR

AT+CMMSDELBCC

+CME ERROR: <err>

Defined values

<addr>

Page 436: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 435

Mobile phone number or email address. As mobile phone number, the max length is 40; As email address, the max length is 60;

Examples

AT+CMMSDELBCC=? +CMMSDELRECP: "ADDRESS" OK AT+CMMSDELBCC OK AT+CMMSDELBCC=”13818362596" OK

19.14 AT+CMMSRECV Receive MMS

Description This command is used to receive MMS. It can only perform in non-edit mode of MMS

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSRECV=? +CMMSRECV: ”LOCATION”

OK Write Command Responses

OK +CMMSRECV: 0 ERROR

AT+CMMSRECV=<location>

+CME ERROR: <err> Or OK +CME ERROR :<err>

Defined values

<location> Reported by +WAP_PUSH_MMS message

Page 437: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 436

Examples

AT+CMMSRECV=”http://211.136.112.84/MI76xou_anB” OK +CMMSRECV: 0 AT+CMMSRECV= http://211.136.112.84/MI76xou_anB” OK +CME ERROR: 190 AT+CMMSRECV=”http://211.136.112.84/MI76xou_anB” +CME ERROR: 177

19.15 AT+CMMSVIEW View information of MMS in box or memory

Description This command is used to view information of MMS in box or memory. The title part of the MMS is formatted with UCS2 little endian character set.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSVIEW=? +CMMSVIEW: (0,1)

OK

Write Command Responses +CMMSVIEW:<mmstype>,”<sender>”,”<receipts>”,”<ccs>”,”<bccs>”,”<datetime>”,”<subject>”,<size><CR><LF>list of <fileIndex, name, type, filesize><CR><LF> OK ERROR

AT+CMMSVIEW=<index>

+CME ERROR: <err>

Execute Command Responses +CMMSVIEW:<mmstype>,”<sender>”,”<receipts>”,”<ccs>”,”<bccs>”,”<datetime>”,”<subject>”,<size><CR><LF>list of <fileIndex, name, type,fileSize><CR><LF> OK ERROR

AT+CMMSVIEW

+CME ERROR: <err>

Defined values

<index>

Page 438: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 437

The MMS mail box index <mmstype> The state of MMS:

0 – Received MMS. 1 – Sent MMS. 2 – Unsent MMS.

<sender> The address of sender <receipts> The list of receipts separated by “;” <ccs> The list of copy receipts separated by “;” <bccs> The list of secret receipts separated by “;” <time> For received MMS, it is the time to receive the MMS. For other MMS, it is the time to create the MMS. <subject> MMS title <size> MMS data size <fileIndex> The index of each file contained in the MMS body <name> The name of each file contained in the MMS body <type> The type of each file contained in the MMS body:

-1 – unknown type. 2 – text. 3 – text/html. 4 – text/plain. 5 – image. 6 – image/gif. 7 – image/jpg. 8 – image/tif. 9 – image/png. 10 – audio/midi. 11 – audio/x-wav. 12 – audio /amr. 13 – audio /mpeg. 14 – video /mp4. 15 – video /3gpp. 29 – application/sdp.

Page 439: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 438

30 – application/smil. <fileSize> The size of each file contained in the MMS body

Examples

AT+CMMSVIEW=? +CMMSVIEW: (0,1) OK AT+CMMSVIEW +CMMSVIEW:2,"",,,,"0000-00-00 00:00:00","dsidfisids",83867 0,"1.txt",4,10 1,"80.jpg",7,83794 OK AT+CMMSVIEW=1 +CMMSVIEW:0,"",,,,"2009-03-10 10:06:12","my title",83867 0,"1.txt",4,10 1,"80.jpg",7,83794 OK

19.16 AT+CMMSREAD read the given file in MMS currently in

memory

Description This command is used to read a given file in MMS currently in memory. When reading a text file, it will be converted to UCS2 little endian before final UART output.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSREAD=? OK

Write Command Responses +CMMSREAD:<name>,<datSize> <FileContent> OK

AT+CMMSREAD=<index>

ERROR

Page 440: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 439

+CME ERROR: <err>

Defined values

<index> The index of the given file contained in the MMS body <name> The name of the given file contained in the MMS body <datSize> The size of the given file contained in the MMS body <FileContent> The content of the file to read

Examples

AT+CMMSREAD=? OK AT+CMMSREAD=3 +CMMSREAD:"1.jpg",83794 …(File Content) OK

19.17 AT+CMMSSNATCH snatch the given file in MMS

Description This command is used to snatch the given file in MMS currently in memory, and save it to UE file system. If the file of input name already exists in the selected directory, it will fail.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSSNATCH=? OK

Write Command Responses OK ERROR

AT+CMMSSNATCH=<index>,<dir>,”<filename>”

+CME ERROR: <err>

Defined values

Page 441: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 440

<index> The index of the given file contained in the MMS body <dir> The directory of the selected file:

0 – current directory[[refer to AT+FSCD] <filename> The name of the given file contained in the MMS body

Examples

AT+CMMSSNATCH=? OK AT+CMMSSNATCH=3,2,”mylocalfile.jpg” OK

19.18 AT+CMMSSAVE Save the MMS to a mail box

Description This command is used to save the selected MMS into a mailbox.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSSAVE=? +CMMSSAVE: (0-1),(0-2)

OK

Write Command Responses +CMMSSAVE: <index> OK ERROR

AT+CMMSSAVE=<index>[,<mmstype>]

+CME ERROR: <err>

Execute Command Responses +CMMSSAVE: <index> OK ERROR

AT+CMMSSAVE

+CME ERROR: <err>

Defined values

<index>

Page 442: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 441

The index of mail box selected to save the MMS <mmstype> The status of MMS:

0 – Received MMS. 1 – Sent MMS. 2 – Unsent MMS.

Examples

AT+CMMSSAVE=? +CMMSSAVE: (0-1),(0-2) OK AT+CMMSSAVE=1 +CMMSSAVE: 1 OK

19.19 AT+CMMSDELETE Delete MMS in the mail box

Description This command is used to delete MMS in the mailbox. The execute command is used to delete all MMS in the mailbox.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSDELETE=? +CMMSDELETE: (0-1)

OK

Write Command Responses +CMMSDELETE: <mmsNum> OK ERROR

AT+CMMSDELETE?

+CME ERROR: <err>

Write Command Responses OK ERROR

AT+CMMSDELETE=<index>

+CME ERROR: <err> Execute Command Responses

OK AT+CMMSDELETE ERROR

Page 443: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 442

+CME ERROR: <err>

Defined values

<index> The index of mail box selected to save the MMS <mmsNum> The number of MMS saved in the mail box

Examples

AT+CMMSDELETE=? +CMMSDELETE: (0-1) OK AT+CMMSDELETE OK AT+CMMSDELETE=1 OK

19.20 AT+CMMSSYSSET Configure MMS transferring parameters

Description This command is used to configure MMS transferring setting.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSSYSSET=? +CMMSSYSSET:

(10240-<max_pdu_size>),(512-4096),(512-4096),(1-<wap_send_buf_count>) OK

Write Command Responses AT+CMMSSYSSET? +CMMSSYSSET: < max_pdu_size

>,<wap_send_buf_size>,<wap_recv_buf_size>,<wap_send_buf_count> OK

Write Command Responses OK AT+CMMSSYSSET=<

max_pdu_size ERROR

Page 444: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 443

>[,<wap_send_buf_size>[,<wap_recv_buf_size>[,<wap_send_buf_count>]]]

+CME ERROR: <err>

Defined values

< max_pdu_size > The maximum MMS pdu size allowed by operator. <wap_send_buf_size> The length of WTP PDU for sending <wap_recv_buf_size> The length of WTP PDU for receiving <wap_send_buf_count> The count of buffers for WTP sending in group

Examples

AT+CMMSSYSSET=? +CMMSSYSSET: (10240-102400),(512-4096),(512-4096),(1-8) OK AT+CMMSSYSSET? +CMMSSYSSET:102400,1460,1500,6 OK AT+CMMSSYSSET=102400,1430,1500,8 OK AT+CMMSSYSSET=102400 OK

19.21 AT+CMMSINCLEN Increase the length of audio/video

attachment header

Description The command is used to increase the length of video/audio attachment header length in the length indicator field. This command is used to be compatible with some operators. This command must be set before calling AT+CMMSEDIT=1. SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSINCLEN=? +CMMSINCLEN: (0,1)

Page 445: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 444

OK

Read Command Responses AT+CMMSINCLEN? +CMMSINCLEN: <mode>

OK

Write Command Responses OK ERROR

AT+CMMSINCLEN=<mode>

+CME ERROR: <err>

Defined values

<mode> Whether to increase the length:

0 – No. 1 – Yes.

Examples

AT+CMMSINCLEN=0 OK AT+CMMSINCLEN? +CMMSINCLEN:0 OK AT+CMMSINCLEN=? +CMMSINCLEN:(0-1) OK

19.22 AT+CMMSUA Set the User-Agent of MMS packet

Description The command is used to set the User-Agent of MMS packet.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSUA=? +CMMSUA:”UserAgent”

OK

Read Command Responses

Page 446: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 445

AT+CMMSUA? +CMMSUA: “<useragent>” OK

Write Command Responses OK ERROR

AT+CMMSUA=”<useragent>”

+CME ERROR: <err>

Defined values

<useragent> The User-Agent of MMS packet. The maximum length is 511 bytes.

Examples

AT+CMMSUA=” Test my UserAgent” OK AT+CMMSUA? +CMMSUA:” Test my UserAgent” OK AT+CMMSUA=? +CMMSUA:”UserAgent” OK

19.23 AT+CMMSPROFILE Set the User-Agent profile of MMS packet

Description The command is used to set the User-Agent profile of MMS packet.

SIM PIN References

YES Vendor

Syntax

Test Command Responses AT+CMMSPROFILE=? +CMMSPROFILE:”UserAgentProfile”

OK

Read Command Responses AT+CMMSPROFILE? +CMMSPROFILE: “<profile>”

OK

Write Command Responses OK AT+CMMSPROFILE=”<pr

ofile>” ERROR

Page 447: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 446

+CME ERROR: <err>

Defined values

<profile> The User-Agent profile of MMS packet. The maximum length is 511 bytes.

Examples

AT+CMMSPROFILE=” Test my UserAgent profile” OK AT+CMMSPROFILE? +CMMSUA:” Test my UserAgent profile” OK AT+CMMSPROFILE=? +CMMSPROFILE:”UserAgent profile” OK

19.24 Supported Unsolicited Result Codes in MMS

Description This section lists all the unsolicited result code in MMS module.

19.24.1 Indication of Sending/Receiving MMS

MMS Sending Description +CMMSSEND:<err> This indication means the result of sending MMS. If successful, it

reports +CMMSSEND:0, or else, it report +CMMSSEND:<err>

MMS Notification Description +WAP_PUSH_MMS:<sender>,<transaction_id>,<location>,<timestamp>,<class>,<size>

This indication means there is a new MMS received in the MMS center.

MMS Receiving Description +CMMSRECV:<err> This indication means the result of receiving MMS. If

successful, it reports +CMMSRECV:0, or else, it report +CMMSRECV:<err>

Defined values

< sender>

Page 448: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 447

The sender address of the received MMS <transaction_id> The X-Mms-Transaction-ID of the received MMS <location> The X-Mms-Content-Location of the received MMS <timestamp> The timestamp of the WAP push message <class> The X-Mms-Class of the received MMS

0 – Expired 1 – Retrieved 2 – Rejected 3 – Deferred 4 – Unrecognized

<size> The size of the received MMS

Examples

+WAP_PUSH_MMS +WAP_PUSH_MMS: "15001844675","RROpJGJVyjeA","http://211.136.112.84/RROpJGJVyjeA" ,"09/03/17,17:14:41+32",0,13338

19.24.2 Summary of CME ERROR Codes for MMS

Code of <err> Description 201 Unknown error for mms

171 MMS task is busy now

172 The mms data is over size 173 The operation is over time 174 There is no mms receiver 175 The storage for address is full 176 Not find the address 177 Invalid parameter 178 Failed to read mms 179 There is not a mms push message (reserved) 180 Memory error 181 Invalid file format 182 The mms storage is full 183 The box is empty 184 Failed to save mms 185 Busy editing mms now

Page 449: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 448

186 Not allowed to edit now 187 No content in the buffer 188 Failed to receive mms 189 Invalid mms pdu 190 Network error 191 Failed to read file in UE

Page 450: Simcom Sim5320 Atc en v1.23

20 CSCRIPT Commands

20.1 AT+CSCRIPTSTART Start running a LUA script file.

Description The command is used to start running a LUA script file. The script file must exist in c:\ in the module EFS. This command shouldn’t be used by sio LIB in LUA script files.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CSCRIPTSTART=? +CSCRIPTSTART: ”FILENAME”

OK

Write Command Responses OK +CSCRIPT: 0 ERROR

AT+CSCRIPTSTART=” <filename>”[ , ” <reportluaerror> ”]

OK +CSCRIPT: <err>

Defined values

<filename> The script file name. <reportluaerror> Whether report the LUA compiling error or running error to TE.

0 – Not report. 1 – Report.

<err> The error code of running script.

Examples

AT+CSCRIPTSTART=”mytest.lua” OK +CSCRIPT: 0 AT+CSCRIPTSTART=? OK

Page 451: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 450

20.2 AT+CSCRIPTSTOP Stop the current running LUA script.

Description The command is used to stop the current running LUA script. This command shouldn’t be used by sio LIB in LUA script files.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CSCRIPTSTOP=? OK

Read Command Responses

AT+CSCRIPTSTOP? +CSCRIPTSTOP: ” <filename>” OK

Execute Command Responses OK AT+CSCRIPTSTOP ERROR

Defined values

<filename> The script file name.

Examples

AT+CSCRIPTSTOP? +CSCRIPTSTOP: ”mytest.lua” OK AT+CSCRIPTSTOP=? OK AT+CSCRIPTSTOP OK

20.3 AT+CSCRIPTCL Compile a LUA script file.

Description

Page 452: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 451

The command is used to compile a LUA script file. The script file must exist in c:\ in the module EFS. This command shouldn’t be used by sio LIB in LUA script files. If the AT+CSCRIPTPASS is set, the compiled file will be encrypted. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CSCRIPTCL=? +CSCRIPTCL: ”FILENAME”, ”OUT_FILENAME”

OK

Write Command Responses OK +CSCRIPT: 0 ERROR

AT+CSCRIPTCL=” <filename>”[ , ” <out_filename> ”]

OK +CSCRIPT: <err>

Defined values

<filename> The script file name. <out_filename> The output script file name. If this parameter is empty, the default <out_filename> will be the file name of <filename> with the file extension changed to “.out”. <err> The error code of running script.

Examples

AT+CSCRIPTCL=”mytest.lua” OK +CSCRIPT: 0 AT+CSCRIPTCL=? +CSCRIPTCL: “FILENAME”, “OUT_FILENAME” OK

20.4 AT+CSCRIPTPASS Set the password for +CSCRIPTCL.

Description The command is used to set the password which will be used for AT+CSCRIPTCL encryption.

Page 453: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 452

SIM PIN References

NO Vendor

Syntax

Write Command Responses OK AT+CSCRIPTCL=”

<old_password>” , ” <new_password> ”

ERROR

Defined values

<old_password> The old password. The original password for AT+CSCRIPTCL is empty. <new_password> The new password.

Examples

AT+CSCRIPTPASS=””,”12345678” OK AT+CSCRIPTPASS=”12345678”,”123456” OK

20.5 AT+CSCRIPTCMD Send data to the running LUA script.

Description The command is used to send data to the running LUA script

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CSCRIPTCMD=? +CSCRIPTCMD: CMD1[,CMD2]

OK

Execute Command Responses OK AT+CSCRIPTCMD=<cmd1

>[,<cmd2>] ERROR

Defined values

Page 454: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 453

<cmd1> An integer value to be sent as the second parameter of EVENT 31 to running LUA script. <cmd2> An integer value to be sent as the third parameter of EVENT 31 to running LUA script.

Examples

AT+CSCRIPTCMD=? +CSCRIPTCMD: CMD1[,CMD2] OK AT+CSCRIPTCMD=23,98 OK

20.6 AT+PRINTDIR Set the value of LUA printdir function.

Description The command is used to set the value of LUA printdir function

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+PRINTDIR=? +PRINTDIR: (0,1)

OK

Read Command Responses AT+PRINTDIR? +PRINTDIR: <mode>

OK

Write Command Responses OK AT+PRINTDIR=<mode> ERROR

Defined values

<mode> The value of printdir:

0 – print function is disabled. 1 – print function is enabled.

Examples

Page 455: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 454

AT+PRINTDIR=0 OK AT+PRINTDIR? +PRINTDIR:0 OK AT+PRINTDIR=? +PRINTDIR:(0-1) OK

20.7 Unsolicited CSCRIPT codes

Summary of +CSCRIPT Codes

Code of <err> Description 0 Success

1 No resource

2 Failed to open the script file 3 Failed to run the script file 4 Failed to compile the script file 5 Virtual machine is busy

21 GPS Related Commands

21.1 AT+CGPS Start/stop GPS session

Description The command is used to start or stop GPS session. NOTE 1. Output of NMEA sentences is automatic; no control via AT commands is provided. You

can configure NMEA or UART port for output by using AT+CGPSSWITCH. At present only support standalone mode. If executing AT+CGPS=1, the GPS session will choose cold or hot start automatically.

2. UE-based and UE-assisted mode depends on URL (AT+CGPSURL) and certificate (AT+CGPSSSL). When UE-based mode failing, it will switch standalone mode.

3. UE-assisted mode is single fix. Standalone and UE-based mode is consecutive fix. 4. After close GPS, need to wait about 2s~30s for next start. Reason:If the signal

conditions are right (strong enough signals to allow ephemeris demodulation) or ephemeris demodulation is on going, sometimes MGP will stay on longer in order to demodulate more ephemeris. This will help the engine provide faster TTFF and possibly better yield later (up to 2 hours), because it has the benefit of more ephemeris

Page 456: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 455

available.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CGPS=? +CGPS: (list of supported <on/off>s),( list of supported <mode>s)

OK

Read Command Responses AT+CGPS? +CGPS: <on/off>,<mode>

OK

Write Command Responses OK If UE-assisted mode, when fixed will report indication: +CAGPSINFO:<lat>,<lon>,<alt>,<date>,<time>

AT+CGPS=<on/off> [,<mode>]

ERROR

Defined values

<on/off> 0 – stop GPS session 1 – start GPS session

<mode> Ignore - standalone mode

1 – standalone mode 2 – UE-based mode 3 – UE-assisted mode

<lat> Latitude of current position. Unit is in 10^8 degree <log> Longitude of current position. Unit is in 10^8 degree <alt> MSL Altitude. Unit is meters. <date> UTC Date. Output format is ddmmyyyy <time> UTC Time. Output format is hhmmss.s

Examples

AT+CGPS? OK

Page 457: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 456

AT+CGPS=1,1 OK

21.2 AT+CGPSINFO Get GPS fixed position information

Description The command is used to get current position information.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CGPSINFO=? +CCGPSINFO: (scope of <time>)

OK

Read Command Responses AT+CGPSINFO? +CCGPSINFO: <time>

OK

Write Command Responses OK +CGPSINFO: [<lat>],[<N/S>],[<log>],[<E/W>],[<date>],[<UTC time>],[<alt>],[<speed>],[<course>] AmpI/AmpQ: <AmpI>/<AmpQ> ……

AT+CGPSINFO=<time>

OK (if <time>=0)

Execution Command Responses AT+CGPSINFO +CGPSINFO: [<lat>],[<N/S>],[<log>],[<E/W>],[<date>],[<UTC

time>],[<alt>],[<speed>],[<course>] AmpI/AmpQ: <AmpI>/<AmpQ> OK

Defined values

<lat> Latitude of current position. Output format is ddmm.mmmm <N/S> N/S Indicator, N=north or S=south <log> Longitude of current position. Output format is dddmm.mmmm <E/W>

Page 458: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 457

E/W Indicator, E=east or W=west <date> Date. Output format is ddmmyy <UTC time> UTC Time. Output format is hhmmss.s <alt> MSL Altitude. Unit is meters. <speed> Speed Over Ground. Unit is knots. <AmpI> The value of AmpI. <AmpQ> The value of AmpQ. <course> Course. Degrees. <time> The range is 0-255, unit is second, after set <time> will report the GPS information every the seconds.

Examples

AT+CGPSINFO=? +CGPSINFO: (0-255) OK AT+CGPSINFO? +CGPSINFO: 0 OK AT+CGPSINFO +CGPSINFO:3113.343286,N,12121.234064,E,250311,072809.3,44.1,0.0,0 AmpI/AmpQ: 420/421 OK

21.3 AT+CGPSCOLD Cold start GPS

Description The command is used to cold start GPS session. NOTE Before using this command,it must use AT+CGPS=0 to stop GPS session.

Syntax

Test Command Responses

SIM PIN References

NO Vendor

Page 459: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 458

AT+CGPSCOLD=? OK Execution Command Responses AT+CGPSCOLD OK

Examples

AT+CGPSCOLD=? OK AT+CGPSCOLD OK

21.4 AT+CGPSHOT Hot start GPS

Description The command is used to hot start GPS session NOTE Before using this command, must use AT+CGPS=0 to stop GPS session. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CGPSHOT=? OK Execution Command Responses AT+CGPSHOT OK

Examples

AT+CGPSHOT=? OK AT+CGPSHOT OK

21.5 AT+CGPSSWITCH Configure output port for NMEA sentence

Description The command is used to choose the output port for NMEA sentence. NOTE Support NMEA output over the UART or NMEA port. You can choose only one port for

the NMEA sentence. If choosing UART port, Baud rate of host must be set 115200 bit/s, and can’t input AT commands through UART port, and the NMEA port is disabled absolutely. If choosing NMEA port for NMEA sentence, the UART port function is

Page 460: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 459

integrated.It takes effect after rebooting.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CGPSSWITCH=? +CGPSSWITCH: (list of supported <port>s)

OK Read Command Responses AT+CGPSSWITCH? +CGPSSWITCH: <port>

OK

Write Command Responses OK AT+CGPSSWITCH=<port>

ERROR

Defined values

<port> 1 – NMEA ports 2 – UART port

Examples

AT+CGPSSWITCH=? +CGPSSWITCH:(1,2) OK AT+CGPSSWITCH=1 OK

21.6 AT+CGPSURL Set AGPS default server URL

Description The command is used to set AGPS default server URL. It will take effect only after restarting.

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CGPSURL=? OK

Page 461: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 460

Read Command Responses AT+CGPSURL? +CGPSURL:<URL>

OK Write Command Responses

OK AT+CGPSURL=<URL>

ERROR

Defined values

<URL> AGPS default server URL. It needs double quotation marks.

Examples

AT+CGPSURL=”123.123.123.123:8888” OK AT+CGPSURL? +CGPSURL:” 123.123.123.123:8888” OK

21.7 AT+CGPSSSL Set AGPS transport security

Description The command is used to select transport security, used certificate or not. The certificate gets from local carrier. If the AGPS server doesn’t need certificate, execute AT+CGPSSSL=0. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CGPSSSL=? +CGPSSSL: (list of supported <SSL>s)

OK

Read Command Responses AT+CGPSSSL? +CGPSSSL=<SSL>

OK

Write Command Responses

OK AT+CGPSSSL=<SSL>

ERROR

Defined values

Page 462: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 461

<SSL> 0 – don’t use certificate 1 – use certificate

Examples

AT+CGPSSSL=0 OK

21.8 AT+CGPSAUTO Start GPS automatic

Description The command is used to start GPS automatic when module power on, default GPS is closed.

NOTE If GPS start automatically, its operation mode is standalone mode. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CGPSAUTO=? +CGPSAUTO:( list of supported <auto>s)

OK

Read Command Responses AT+CGPSAUTO? +CGPSAUTO:<auto>

OK Write Command Responses

OK AT+CGPSAUTO=<auto>

ERROR

Defined values

<auto> 0 – Non-automatic

1 – automatic

Examples

AT+CGPSAUTO=1 OK

Page 463: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 462

21.9 AT+CGPSNMEA Configure NMEA sentence type

Description The command is used to configure NMEA output sentences which are generated by the gpsOne engine when position data is available. NOTE If bit 2 GPGSV didn’t configure, GPGSV sentence also didn’t output on AT/modem port even set AT+CGPSFTM=1. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CGPSNMEA=? +CGPSNMEA: (scope of <nmea>)

OK

Read Command Responses AT+CGPSNMEA? +CGPSNMEA: <nmea>

OK

Write Command Responses OK AT+CGPSNMEA=<nmea>

If GPS engine is running: ERROR

Defined values

<nmea> Range – 0 to 31 Each bit enables an NMEA sentence output as follows: Bit 0 – GPGGA (global positioning system fix data) Bit 1 – GPRMC (recommended minimum specific GPS/TRANSIT data) Bit 2 – GPGSV (GPS satellites in view) Bit 3 – GPGSA (GPS DOP and active satellites) Bit 4 – GPVTG (track made good and ground speed) Set the desired NMEA sentence bit(s). If multiple NMEA sentence formats are desired, “OR” the desired bits together.

Examples

AT+CGPSNMEA=31 OK

Page 464: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 463

21.10 AT+CGPSMD Configure AGPS MO method

Description The command specifies if the Mobile-Originated (MO) GPS session should use the control plane session or user plane session. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CGPSMD=? +CGPSMD: (scope of <method>)

OK

Read Command Responses AT+CGPSMD? +CGPSMD: <method>

OK

Write Command Responses OK AT+CGPSMD=<method>

If GPS engine is running: ERROR

Defined values

<method> 0 – Control plane 1 – User plane

Examples

AT+CGPSMD=1 OK

21.11 AT+CGPSFTM Start GPS test mode

Description The command is used to start GPS test mode. NOTE 1. If test mode started, the URC will report on AT port, Modem port and UART port. 2. If testing on actual signal, <SV> should ignore, and must start GPS by AT+CGPS, AT+CGPSCOLD or AT+CGPSHOT. 3. If testing on GPS signal simulate equipment, must choice <SV>, and GPS will start

Page 465: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 464

automatically. 4. URC sentence will report every 1 second. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CGPSFTM=? OK

Read Command Responses AT+CGPSFTM? +CGPSFTM: <on/off>

OK Write Command Responses

OK AT+CGPSFTM=<on/off>

ERROR

Defined values

<on/off> 0 – Close test mode

1 – Start test mode <CNo>

Satellite CNo value. Floating value. URC format

$GPGSV[,<SV>,<CNo>][...]

Examples

AT+CGPSFTM=1 OK $GPGSV,3,44.5,13,45.6,32,35.3,19,39.1,23,42.5,21,38.8 $GPGSV,3,44.9,13,45.5,32,35.5,19,39.8,23,42.9,21,38.7

21.12 AT+CGPSDEL Delete the GPS information

Description The command is used to delete the GPS information. After executing the command, GPS start is cold start. SIM PIN References

NO Vendor

Syntax

Page 466: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 465

Test Command Responses AT+CGPSDEL=? OK

Execution Command Responses OK AT+CGPSDEL

ERROR

Examples

AT+CGPSDEL=? OK AT+CGPSDEL OK

21.13 AT+CGPSNOTIFY LCS respond positioning request

Description The command is used to respond to the incoming request for positioning request message. NOTE This command only for A version. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CGPSNOTIFY=? +CGPSNOTIFY: (list of supported <resp>s)

OK

Write Command Responses OK AT+CGPSNOTIFY=<resp>

ERROR

Defined values

<resp> 0 – LCS notify verify accept 1 – LCS notify verify deny 2 – LCS notify verify no response

Examples

AT+CGPSNOTIFY=? +CGPSNOTIFY: (0-2) OK

Page 467: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 466

AT+CGPSNOTIFY=0 OK

21.14 AT+ CGPSXE Enable/disable GPS XTRA function

Description The command is used to enable/disable the GPS XTRA function. NOTE The function will take effect after restarting the module. XTRA function must download the assistant file form network by HTTP, so must set the APN by AT+CGSOCKCONT command. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CGPSXE=? +CGPSXE: (list of supported <on/off>s)

OK

Read Command Responses AT+CGPSXE? +CGPSXE: <on/off>

OK

Write Command Responses OK AT+CGPSXE=<on/off>

ERROR

Defined values

<on/off> 0 – Disable GPS XTRA 1 – Enable GPS XTRA

Examples

AT+CGPSXE=? +CGPSNOTIFY: (0,1) OK AT+CGPSXE=0 OK

Page 468: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 467

21.15 AT+CGPSXD Download XTRA assistant file

Description The command is used to download the GPS XTRA assistant file form network through http protocol. Module will download the latest assistant file form server and write the file into module. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CGPSXD=? +CGPSXD: (list of supported <server>s)

OK

Read Command Responses AT+CGPSXD? +CGPSXD: <server>

OK

Write Command Responses OK +CGPSXD: <resp>

AT+CGPSXD=<server>

ERROR

Defined values

<server> 0 – XTRA primary server (precedence) 1 – XTRA secondary server 2 – XTRA tertiary server

<resp> refer to Unsolicited XTRA download Codes

Examples

AT+CGPSXD=? +CGPSXD: (0-2) OK AT+CGPSXD=0 OK +CGPSXD: 0

Page 469: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 468

21.16 AT+CGPSXDAUTO Download XTRA assistant file automatically

Description The command is used to control download assistant file automatically or not when GPS start. XTRA function must enable for using this command. If assistant file doesn’t exist or check error, the module will download and inject the assistant file automatically. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CGPSXDAUTO=? +CGPSXDAUTO: (list of supported <on/off>s)

OK

Read Command Responses AT+CGPSXDAUTO? +CGPSXDAUTO: <on/off>

OK

Write Command Responses OK AT+CGPSXDAUTO=<on/o

ff> ERROR

Defined values

<on/off> 0 – disable download automatically 1 – enable download automatically

NOTE Some URCs will report when download, it’s same as AT+CGPSXD command.

Examples

AT+CGPSXDAUTO=? +CGPSXDAUTO: (0,1) OK AT+CGPSXDAUTO=0 OK

21.17 AT+CGPSINFOCFG Report GPS NMEA-0183 sentence

Description The command is used to report NMEA-0183 sentence.

Page 470: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 469

SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CGPSINFOCFG=? +CCGPSINFOCFG: (scope of <time>),(scope of <config>)

OK

Read Command Responses AT+CGPSINFOCFG? +CCGPSINFOCFG: <time>, <config>

OK

Write Command Responses OK (NMEA-0183 Sentence) ……

AT+CGPSINFOCFG=<time>,<config>

OK (if <time>=0)

Defined values

<time> The range is 0-255, unit is second, after set <time> will report the GPS NMEA sentence every the seconds. If <time>=0, module stop reporting the NMEA sentence. <config> Range – 0 to 31. Default value is 0. Each bit enables an NMEA sentence output as follows: Bit 0 – GPGGA (global positioning system fix data) Bit 1 – GPRMC (recommended minimum specific GPS/TRANSIT data) Bit 2 – GPGSV (GPS satellites in view) Bit 3 – GPGSA (GPS DOP and active satellites) Bit 4 – GPVTG (track made good and ground speed) Set the desired NMEA sentence bit(s). If multiple NMEA sentence formats are desired, “OR” the desired bits together. For example: If want to report GPRMC sentence by 10 seconds, should execute AT+CGPSINFOCFG=10,2

Examples

AT+CGPSINFOCFG=? +CGPSINFO: (0-255),(0-31) OK AT+CGPSINFOCFG=10,31

Page 471: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 470

OK $GPGSV,4,1,16,04,53,057,44,02,55,334,44,10,61,023,44,05,45,253,43*7D $GPGSV,4,2,16,25,10,300,40,17,25,147,40,12,22,271,38,13,28,053,38*77 $GPGSV,4,3,16,26,09,187,35,23,06,036,34,24,,,,27,,,*7A $GPGSV,4,4,16,09,,,,31,,,,30,,,,29,,,*7D $GPGGA,051147.0,3113.320991,N,12121.248076,E,1,10,0.8,47.5,M,0,M,,*45 $GPVTG,NaN,T,,M,0.0,N,0.0,K,A*42 $GPRMC,051147.0,A,3113.320991,N,12121.248076,E,0.0,0.0,211211,,,A*66 $GPGSA,A,3,02,04,05,10,12,13,17,23,25,26,,,1.4,0.8,1.2*3B

21.18 Unsolicited XTRA download Codes

Code of <err> Description 0 Assistant file download successfully 1 Assistant file doesn’t exist 2 Assistant file check error 220 Unknown error for HTTP 221 HTTP task is busy 222 Failed to resolve server address 223 HTTP timeout 224 Failed to transfer data 225 Memory error 226 Invalid parameter 227 Network error 220~227 codes are same as Unsolicited HTTP codes

21.19 Cell Location

21.19.1 AT+CASSISTLOC Start/Stop assist location

Description The command is used to start or stop the assist location. When start, it will connect Google server and post request, then receive response. When stop, it will stop the location and release the resource. SIM PIN References

YES Vendor

Syntax

Test Command Responses

Page 472: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 471

+CASSISTLOC: (0-2),(1-16),(language),(1-24*60*60) OK

AT+CASSISTLOC=?

ERROR

Execution Command Responses If autorun = 0: OK +CASSISTLOC: <return code> If autorun = 1: OK +CASSISTLOC:<charset>,<latitude>,<longitude>,<altitude>,<accuracy>,<altitude_accuracy>,<street_num>,<street>,<premises>,<city>,<county>,<region>,<country>,<country_code>,<postal_code> +CASSISTLOC: <return code> If autorun = 2: OK +CASSISTLOC:<charset>,<latitude>,<longitude>,<altitude>,<accuracy>,<altitude_accuracy>,<street_num>,<street>,<premises>,<city>,<county>,<region>,<country>,<country_code>,<postal_code>+CASSISTLOC:<charset>,<latitude>,<longitude>,<altitude>,<accuracy>,<altitude_accuracy>,<street_num>,<street>,<premises>,<city>,<county>,<region>,<country>,<country_code>,<postal_code>……

ERROR

AT+CASSISTLOC= <autorun>[,<cid>[,<language>,< time_between_fix>] ]

+CME ERROR: <error message>

Defined values

< autorun > 0 – stop location 1 – start location, only once(Must set the cid) 2 – start cycle location (Must set the cid)

< cid > network parameters, refer to AT+CGSOCKCONT. < language > accept language. Refer to Google standard: en_GB, zh_CN and so on. Not required, the default value is en_GB < time_between_fix > Time interval of fix(second),range: 1 second – 24 hours. Not required, the default value is 1 second. < charset >

Page 473: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 472

charset for URC. ASCII, UTF-8 and so on. < latitude > Latitude of current position. in degrees. < longitude > Longitude of current position. in degrees. < altitude > Altitude of the fix. Unit is meters(not required). < accuracy > The horizontal accuracy of the fix, in meters at a 95% confidence level. This is required unless the request specified a valid location object, i.e. a request for a reverse-geocode of a known position(not required) < altitude_accuracy > The accuracy of the altitude, in meters(not required) < street_num > The building's street number(not required) < street > Street name(not required) < premises > Premises, e.g. building name(not required) < city > City name(not required) < county > County name(not required). < region > Region, e.g. a state in the US(not required) < country > Country(not required) < country_code > Country code(not required) < postal_code > Postal code. This is the zip code in the US and postcode in the UK(not required). < return code > The result code of the location. 0 – OK 1 – Unknow error 2 – Invalid param error 3 – Bad got error 4 – network error NOTE: 1. When <autorun> is set to 0 and the others parameters not be given (AT+CASSISTLOC=0), the command is to stop the location. 2.When <autorun> is set to 1 or 2, <cid> is required, but <language>,< time_between_fix> is not required.

Page 474: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 473

3. When <autorun> is set to 2 and there is an error occurred, there is not an error report, the location is continuing.

Examples

AT+CASSISTLOC=? + CASSISTLOC: (0-2) , (1-16),(language),(1-24*60*60) OK AT+CASSISTLOC=1,2,"zh_CN" OK +CASSISTLOC:UTF-8,33312E32323137363537,3132312E33353532343739,,3734322E30,,,E58D8FE5928CE8B7AF,,E4B88AE6B5B7E5B882,,E4B88AE6B5B7E5B882,E4B8ADE59BBD,434E, +CASSISTLOC: 0 AT+CASSISTLOC=2,1,"en_GB",2 OK +CASSISTLOC:,,,,,,,,,,,,, +CASSISTLOC:UTF-8,33312E32323136363439,3132312E33353532353934,,3734322E30,,,5869656865205264,,5368616E67686169,,5368616E67686169,4368696E61,434E, +CASSISTLOC:UTF-8,33312E32323136363439,3132312E33353532353934,,3734322E30,,,5869656865205264,,5368616E67686169,,5368616E67686169,4368696E61,434E, AT+CASSISTLOC=0 OK +CASSISTLOC: 0

21.19.2 AT+ CASSISTLOCTRYTIMES Set retry times

Description The command is used to set the max number to try connection when the http connects if failed. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CASSISTLOCTRYTIMES=?

+CASSISTLOCTRYTIMES: (2-10),(5-60*60) OK

Read Command Responses AT+CASSISTLOCTRYTIMES?

+CASSISTLOCTRYTIMES: <num>,<time> OK

Page 475: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 474

Execution Command Responses OK AT+CASSISTLOCTRYTIM

ES=<num>[, <time>] ERROR

Defined values

< num > the number to retry when error occurred < time > the time between try. The unit is second, range is 5 - 60*60.

Examples

AT+CASSISTLOCTRYTIMES=? +CASSISTLOCTRYTIMES: (2-10),(5-60*60) OK AT+CASSISTILOCTRYTIMES? +CASSISILOCTRYTIMES: 3,5 OK AT+CASSISTLOCTRYTIMES=3,10 OK

21.19.3 AT+ CASSISTLOCMODE Set assist location mode

Description The command is used to set the mode of location: 0 – using single cell; 1 – using more cell. SIM PIN References

NO Vendor

Syntax

Test Command Responses AT+CASSISTLOCMODE=?

+CASSISILOCMODE: (0, 1) OK

Read Command Responses AT+CASSISTLOCMODE? +CASSISTLOCMODE: <mode>

OK

Write Command Responses OK AT+CASSISTLOCMODE=

<mode> ERROR

Page 476: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 475

Defined values

<mode> the location mode: 0 – using single cell; 1 – using more cell

Examples

AT+CASSISTLOCMODE=? +CASSISTLOCMODE: (0,1) OK AT+CASSISTLOCMODE? +CASSISTLOCMODE: 1 OK AT+CASSISTLOCMODE=1 OK

22 Voice Mail Related Commands

The module supports voice mail AT commands.

22.1 AT+CSVM Subscriber number

Description Execution command returns the voice mail number related to the subscriber.

SIM PIN References

YES 3GPP TS 27.007

Syntax

Test Command Responses AT+CSVM=? +CSVM: (0-1), “(0-9,+)”, (128-255)

OK

Read Command Responses

+CSVM: <valid>, “<number>”,<type>

OK

AT+CSVM?

ERROR

Write Command Responses

Page 477: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 476

OK AT+CSVM=<valid>, “<number>”,<type> ERROR

Defined values

<valid> Whether voice mail number is valid:

0 – Voice mail number is invalid. 1 – Voice mail number is valid.

<number> String type phone number of format specified by <type>. <type> Type of address octet in integer format. see also AT+CPBR <type>

Examples

AT+CSVM? +CSVM: 1 ,"13697252277",129 OK

22.2 Indication of Voice Mail

Box Empty Description +VOICEMAIL: EMPTY This indication means the voice mail box is empty

New Message Description +VOICEMAIL: NEW MSG This indication means there is a new voice mail message

notification received. This is for CPHS.

Voice Mail Status Updated Description +VOICEMAIL: WAITING, <count>

This indication means that there are <count> number of voice mail messages that needs to be got.

Defined values

< count> Count of voice mail message that waits to be got.

Examples

+VOICEMAIL: WAITING, <count> +VOICEMAIL: WAITING, 5

Page 478: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 477

23 EONS Related AT commands

The module supports EONS function.

23.1 Indication of EONS

OPL INIT Description OPL DONE This indication means EF-OPL has been read successfully. Only

after this URC is reported, the AT+COPS? can query the network name that supports EONS function.

PNN INIT Description PNN DONE This indication means EF-PNN has been read successfully

OPL UPDATING Description OPL UPDATING This indication means the EF-OPL is updating using OTA

message. After updating, the “OPL DONE” should report.

PNN UPDATING Description PNN UPDATING This indication means the EF-PNN is updating using OTA

message. After updating, the “PNN DONE” should report.

PNN UPDATING This indication means the EF-PNN is updating using OTA message. After updating, the “PNN DONE” should report.

24 OTAD Commands

24.1 AT+COTADPHONENUMBER modify OTAD phone number

Description The command is used to get, add and delete the OTAD phone numbers.

SIM PIN References

NO Vendor

Syntax

Page 479: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 478

Test Command Responses AT+COTADPHONENUMBER=? +COTADPHONENUMBER: (list of supported

<flag>s),PHONE NUM OK

Read Command Responses AT+COTADPHONENUMBER? +COTADPHONENUMBER:<phone num>

OK

Write Command Responses OK ERROR

AT+COTADPHONENUMBER= <flag>,<phone num>

+OTAD ERROR:<err>

Defined values

<flag> OTAD phone numbers add or delete control flag, integer type 1 – add the OTAD phone number to list.

2 – delete the OTAD phone number from list.. < phone num > OTAD phone numbers to be used for OTAD, non empty string without double quotes and smaller than 48 characters. <err> 1. The phone number exist or the list is full 2. The phone number does not exist or the list is empty 3. The phone number is too long or empty 4. The phone number contains illegal character

Examples

AT+COTADPHONENUMBER? +COTADPHONENUMBER:10086;10010 OK AT+COTADPHONENUMBER=1,10086 OK AT+COTADPHONENUMBER=2,10086 OK

Page 480: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 479

25 Result codes

25.1 verbose code and numeric code

Verbose result code Numeric (V0 set) Description OK 0 Command executed, no errors, Wake up after reset CONNECT 1 Link established RING 2 Ring detected NO CARRIER 3 Link not established or disconnected ERROR 4 Invalid command or command line too long NO DIALTONE 6 No dial tone, dialing impossible, wrong mode BUSY 7 Remote station busy NO ANSWER 8 Connection completion timeout

25.2 Response string of AT+CEER

Number Response string CS internal cause 0 Phone is offline 21 No service available 25 Network release, no reason given 27 Received incoming call 29 Client ended call 34 UIM not present 35 Access attempt already in progress 36 Access failure, unknown source 38 Concur service not supported by network 29 No response received from network 45 GPS call ended for user call 46 SMS call ended for user call 47 Data call ended for emergency call 48 Rejected during redirect or handoff 100 Lower-layer ended call 101 Call origination request failed 102 Client rejected incoming call 103 Client rejected setup indication 104 Network ended call 105 No funds available 106 No service available

Page 481: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 480

108 Full service not available 109 Maximum packet calls exceeded 301 Video connection lost 302 Video call setup failure 303 Video protocol closed after setup 304 Video protocol setup failure 305 Internal error CS network cause 1 Unassigned/unallocated number 3 No route to destination 6 Channel unacceptable 8 Operator determined barring 16 Normal call clearing 17 User busy 18 No user responding 19 User alerting, no answer 21 Call rejected 22 Number changed 26 Non selected user clearing 27 Destination out of order 28 Invalid/incomplete number 29 Facility rejected 30 Response to Status Enquiry 31 Normal, unspecified 34 No circuit/channel available 38 Network out of order 41 Temporary failure 42 Switching equipment congestion 43 Access information discarded 44 Requested circuit/channel not available 47 Resources unavailable, unspecified 49 Quality of service unavailable 50 Requested facility not subscribed 55 Incoming calls barred within the CUG 57 Bearer capability not authorized 58 Bearer capability not available 63 Service/option not available 65 Bearer service not implemented 68 ACM >= ACMmax 69 Requested facility not implemented 70 Only RDI bearer is available 79 Service/option not implemented

Page 482: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 481

81 Invalid transaction identifier value 87 User not member of CUG 88 Incompatible destination 91 Invalid transit network selection 95 Semantically incorrect message 96 Invalid mandatory information 97 Message non-existent/not implemented 98 Message type not compatible with state 99 IE non-existent/not implemented 100 Conditional IE error 101 Message not compatible with state 102 Recovery on timer expiry 111 Protocol error, unspecified 117 Interworking, unspecified CS network reject 2 IMSI unknown in HLR 3 Illegal MS 4 IMSI unknown in VLR 5 IMEI not accepted 6 Illegal ME 7 GPRS services not allowed 8 GPRS & non GPRS services not allowed 9 MS identity cannot be derived 10 Implicitly detached 11 PLMN not allowed 12 Location Area not allowed 13 Roaming not allowed 14 GPRS services not allowed in PLMN 15 No Suitable Cells In Location Area 16 MSC temporarily not reachable 17 Network failure 20 MAC failure 21 Synch failure 22 Congestion 23 GSM authentication unacceptable 32 Service option not supported 33 Requested service option not subscribed 34 Service option temporarily out of orde 38 Call cannot be identified 40 No PDP context activated 95 Semantically incorrect message 96 Invalid mandatory information

Page 483: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 482

97 Message type non-existent 98 Message type not compatible with state 99 Information element non-existent 101 Message not compatible with state 161 RR release indication 162 RR random access failure 163 RRC release indication 164 RRC close session indication 165 RRC open session failure 166 Low level failure 167 Low level failure no redial allowed 168 Invalid SIM 169 No service 170 Timer T3230 expired 171 No cell available 172 Wrong state 173 Access class blocked 174 Abort message received 175 Other cause 176 Timer T303 expired 177 No resources 178 Release pending 179 Invalid user data PS internal cause lookup 0 Invalid connection identifier 1 Invalid NSAPI 2 Invalid Primary NSAPI 3 Invalid field 4 SNDCP failure 5 RAB setup failure 6 No GPRS context 7 PDP establish timeout 8 PDP activate timeout 9 PDP modify timeout 10 PDP inactive max timeout 11 PDP lowerlayer error 12 PDP duplicate 13 Access technology change 14 PDP unknown reason PS network cause 25 LLC or SNDCP failure

Page 484: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 483

26 Insufficient resources 27 Missing or unknown APN 28 Unknown PDP address or PDP type 29 User Aauthentication failed 30 Activation rejected by GGSN 31 Activation rejected, unspecified 32 Service option not supported 33 Requested service option not subscribed 34 Service option temporarily out of order 35 NSAPI already used (not sent) 36 Regular deactivation 37 QoS not accepted 38 Network failure 39 Reactivation required 40 Feature not supported 41 Semantic error in the TFT operation 42 Syntactical error in the TFT operation 43 Unknown PDP context 44 PDP context without TFT already activated 45 Semantic errors in packet filter 46 Syntactical errors in packet filter 81 Invalid transaction identifier 95 Semantically incorrect message 96 Invalid mandatory information 97 Message non-existent/not implemented 98 Message type not compatible with state 99 IE non-existent/not implemented 100 Conditional IE error 101 Message not compatible with state 111 Protocol error, unspecified

26 AT Commands Samples

26.1 SMS commands

Commands and Responses Comments AT+CMGF=1 OK

Set SMS system into text mode, as opposed to PDU mode.

Page 485: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 484

AT+CPMS="SM","SM","SM" +CPMS: 0,40,0,40,0,40 OK

Select memory storages.

AT+CNMI=2,1 OK

Set new message indications to TE.

AT+CMGS=“+861358888xxxx” >This is a test <Ctrl+Z> +CMGS:34 OK

Set new message indications to TE.

+CMTI:“SM”,1 Unsolicited notification of the SMS arriving.

AT+CMGR=1 +CMGR: “REC UNREAD”, “+86135888xxxx”, ,“08/01/30, 20:40:31+00” This is a test OK

Read SMS message that has just arrived. NOTE The number should be the same as that given in the +CMTI notification.

AT+CMGR=1 +CMGR: “REC READ”, “+861358888xxxx”,,“08/01/30 , 20:40:31+00” This is a test OK

Reading the message again changes the status to “READ” from “UNREAD”.

AT+CMGS=“+861358888xxxx” >Test again<Ctrl+Z> +CMGS:35 OK

Send another SMS to myself.

+CMTI:“SM”,2 Unsolicited notification of the SMS arriving.

AT+CMGL=“ALL” +CMGL: 1, “REC READ”, “+861358888xxxx”, , “08/01/30,20:40:31+00” This is a test +CMGL: 2, “REC UNREAD”,””, “+861358888xx xx”, , “08/01/30,20:45:12+00” Test again OK

Listing all SMS messages.

AT+CMGD=1 OK

Delete an SMS message.

AT+CMGL=“ALL” +CMGL: 2,“REC READ”,“+861358888xxxx”, “08/01/30,20:45:12+00” Test again

List all SMS messages to show message has been deleted.

Page 486: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 485

OK

26.2 TCP/IP commands

26.2.1 TCP server

Commands and Responses Comments AT+NETOPEN=”TCP”,80 Network opened OK

Activate the specified socket’s PDP context and Create a socket.

AT+SERVERSTART OK

For Tcp Server,it starts a Passive open for connections.

AT+LISTCLIENT NO.0 client : 10.71.34.32 80 NO.1 client : 10.71.78.89 1020 OK

List all of clients’ information.

AT+ACTCLIENT = 0 OK

Activate the specified client.

AT+TCPWRITE=8 >ABCDEFGH +TCPWRITE: 8, 8 OK Send ok

Send data to an active client.

AT+CLOSECLIENT=0 OK

Close the specified client.

AT+NETCLOSE Network closed OK

Close all of clients and Deactivate the specified socket’s PDP context.

26.2.2 TCP client

Commands and Responses Comments AT+NETOPEN=”TCP”,80 Network opened OK

Activate the specified socket’s PDP context and Create a socket.

AT+TCPCONNECT=”192.168.0.1”,80 Attempt to establish the TCP connection

Page 487: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 486

OK with the specified Tcp server. AT+TCPWRITE=8 >ABCDEFGH +TCPWRITE: 8, 8 OK

Send ok

Send data to server.

AT+NETCLOSE Network closed OK

Disconnect the connection with server and Deactivate the specified socket’s PDP context.

+IPCLOSE: <client_index>, <close_reason>, <remote_IP>, <port>. +NETCLOSE: 1

Disconnected by the server NOTE: Client_index: This value identifies the client index; When the mode is single-client, this value is 255. Close_reason: This value is the reason for close. Remote_IP: This value identifies the IP address of sever. Port: This value identifies the port of sever, the range of permitted values is 0 to 65535

26.2.3 UDP

Commands and Responses Comments

AT+NETOPEN=”UDP”,80 Network opened OK

Activate the specified socket’s PDP context and Create a socket.

AT+UDPSEND=8,”192.168.0.1”,80 >ABCDEFGH +UDPSEND: 8, 8 OK

Send data.

AT+NETCLOSE Network closed OK

Close the socket and Deactivate the specified socket’s PDP context.

Page 488: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 487

26.2.4 Multi client

Commands and Responses Comments

AT+NETOPEN=,,1 Network opened OK

Activate the specified socket’s PDP context and Select in multi-client mode

AT+CIPOPEN=0,”TCP”,”116.228.221.51”,100 Connect ok OK

Establish a connection with TCP Server

AT+CIPOPEN=1,”UDP”,”116.228.221.51”,120 OK

Establish a connection with UDP Server

AT+CIPSEND=0,7 >SimTech +CIPSEND: 7, 7 OK Send ok

Send data in the connection of number 0

AT+CIPSEND=1,7 >SimTech +CIPSEND: 7, 7 OK

Send data in the connection of number 1

AT+CIPCLOSE=0 OK

Close the connection of number 0

AT+NETCLOSE OK

Close all of connections and Deactivate the specified socket’s PDP context.

26.3 File transmission flow

The Module supports to transmit files from the Module to PC host and from PC host to the Module over Xmodem protocol. During the process of transmission, it can not emit any AT commands to do other things.

26.3.1 File transmission to PC host

Step1. Select file for transmission to PC host

Page 489: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 488

After HyperTerminal is OK for emitting AT commands, it must select a file by one of following methods:

①. Select directory as current directory by AT+FSCD, and then select file with parameter <dir_type> of AT+CTXFILE is 0 or omitted. [Figure 17-1]

Figure 17-1 Select file for transmission

②. Select the file directly with subparameter <dir_type> of AT+CTXFILE is not 0 and not omitted; this method is a shortcut method for limited directories. [Figure 17-2]

Figure 17-2 Select file directly for transmission

Page 490: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 489

Step2. Open “Receive File” dialog box

After select transmitted file successfully, use “Transfer>Receive File…” menu to open “Receive File” dialog box in HyperTerminal. [Figure 17-3]

Figure 17-3 Open “Receive File” dialog box

Step3. Set storage place and receiving protocol

In “Receive File” dialog box, set the storage place in PC host where file transmitted is saved in text box, and select receiving protocol in combo box.

Then click “Receive” button to open “Receive Filename” dialog box. [Figure 17-4] NOTE The receiving protocol must be “Xmodem” protocol.

Page 491: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 490

Figure 17-4 Storage place and receiving potocol

Step4. Set file name

In “Receive Filename” dialog box, input file name in “Filename” text box. And then click “OK” button to start transmitting file. [Figure 17-5]

Figure 17-5 Set file name

Step5. Transmit the file After start file transmission, it can’t emit any AT commands untill transmission stops. In “Xmodem file receive” dialog box, it will display the process of transmission. [Figure 17-6]

Page 492: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 491

Figure 17-6 Xmodem file receive

If cannel the transmission, HyperTerminal will prompt “Transfer cancelled by user”. [Figure 17-7]

Figure 17-7 Cancel transmission

After transmission successfully, the receiving dialog box is closed and it can emit AT commands in HyperTerminal. [Figure 17-8]

Figure 17-8 Transmission successfully

Page 493: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 492

26.3.2 File received from PC host

Step1. Set file name and storage place

Firstly, it must set file name and storage place in file system of module by one of following methods: ①. Select directory as current directory by AT+FSCD, and then set file name and storage place as

current directory with parameter <dir_type> of AT+CRXFILE is 0 or omitted. [Figure 17-9]

Figure 17-9 Set file name and storage place

②. Set storage place directly with parameter <dir_type> of AT+CTXFILE is not 0 and not omitted; this method is a shortcut method for limited directories.

Step2. Open “Send File” dialog box

After set file name and storage place successfully, use “Transfer>Send File…” menu to open “Send File” dialog box in HyperTerminal. [Figure 17-10]

Page 494: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 493

Figure 17-10 Open “Send File” dialog box

Step3. Select file and transmitting protocol

In “Send File” dialog box, select the file to be transmitted in text box, and select the transmitting protocol in combo box. Then click “Send” button to start transmission. [Figure 17-11]

NOTE The transmitting protocol must be “Xmodem” protocol.

Figure 17-11 Select file and protocol

Step4. File transmission

Page 495: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 494

After start file transmission, it can’t emit any AT commands utill transmission stops. In “Xmodem file send” dialog box, it will display the process of transmission. [Figure 17-12]

Figure 17-12 The process of file transmission

If cannel the transmission, HyperTerminal will prompt “Transfer cancelled by user”. NOTE There may be some characters reported which denote interactions between module and PC

host.

26.4 MMS commands

Set the parameters Comments AT+CMMSCURL=”mmsc.monternet.com” OK

Set the MMS center URL without “http://”

AT+CMMSPROTO=1,”10.0.0.172”,80 OK

Use http protocol to send MMS and set the IP address and port of MMS proxy to “10.0.0.172” and 80

AT+CMMSSENDCFG=6,3,0,0,2,4 OK

Set the parameter of MMS to send. This is unnecessary to set.

Send MMS Comments

AT+CGSOCKCONT=1,”IP”,”cmwap” OK AT+CMMSEDIT=1

Set the PDP context profile. Set the edit mode to 1.

Page 496: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 495

OK AT+CMMSDOWN=”TITLE”,10 >Test title OK AT+CMMSDOWN=”FILE”,3,” 1.jpg” OK AT+CMMSDOWN=”TEXT”,120,”t1.txt” >My test content….(file content, 120 bytes) OK AT+CMMSRECP=”13918181818” OK AT+CMMSRECP=”[email protected]” OK AT+CMMSCC=”15013231222” OK AT+CMMSSAVE=1 +CMMSSAVE: 1 OK AT+CMMSSEND=”13318882322” OK +CMMSSEND:0

Set the title of MMS to “Test title”. Add the “1.jpg” in UE to the MMS body. Add a text file named “t1.txt” with length of 120 bytes. Add a recipient of “13918181818” Add a recipient of [email protected] Add a copy recipient of ”15013231222” Save the MMS to mail box of index 1. Send the MMS including new recipient ”13318882322” After MMS is sent successfully, This command indicates success of sending. If failed, +CME ERROR:<err> will be reported.

Receive MMS Description

+WAP_PUSH_MMS: "15001844675","RROpJGJVyjeA","http://211.136.112.84/RROpJGJVyjeA" ,"09/03/17,17:14:41+32",0,13338 AT+CGSOCKCONT=1,”IP”,”cmwap” OK AT+CMMSEDIT=0 OK

Receiving a new MMS notification. Set the PDP context profile. Set the mms edit mode to 0.

Page 497: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 496

AT+CMMSRECV="http://211.136.112.84/RROpJGJVyjeA" OK +CMMSRECV:0 AT+CMMSSAVE=0 +CMMSSAVE: 0 OK

Receive MMS using the location contained in +WAP_PUSH_MMS indication. After MMS is received successfully, this command indicates success of receiving. If failed, +CME ERROR:<err> will be reported. If receiving successfully, save it to mail box.

Page 498: Simcom Sim5320 Atc en v1.23

SIM5320 AT Command Set

SIM5320_ATC_V1.23 5/14/2012 497

Contact us Shanghai SIMCom Wireless Solutions Ltd. Add: Building A, SIM Technology Building, No.633, Jinzhong Road, Changning District 200335 Tel: +86 21 3252 3300 Fax: +86 21 3252 3301 URL: http:/www.sim.com/wm/