signal integrity test report -...
TRANSCRIPT
PD-0098
Signal Integrity Test Report
3M™ External MiniSAS
Cable Assemblies
3 Electronic Solutions Division 6801 River Place Blvd. Austin, TX 78726-9000
Document Number: PD-0098 Issue Date: August 31, 2011 Title: Signal Integrity Test Report Supersedes: New Subject: 3M™ External MiniSAS Cable Assembly Page: 1 of 14
Table of Contents
3Electronic Solutions Division (PD-0098%20Ext%20MiniSAS%20SI%20Test%20Report[1].docx)
6801 River Place Blvd. Austin, TX 78726-9000 http://www.3Mconnectors.com
1.0 Scope .................................................................................................................................................................... 2 2.0 Product Tested .................................................................................................................................................... 2 3.0 General Conditions ............................................................................................................................................. 2
3.1 Test Specimens ............................................................................................................................................ 2 3.2 Standard Test Conditions .......................................................................................................................... 2
4.0 Test Results Summary ........................................................................................................................................ 3 5.0 Testing .................................................................................................................................................................. 4
5.1 General ........................................................................................................................................................ 4 5.2 Signal Integrity ........................................................................................................................................... 4
SDD21, Differential insertion loss ............................................................................................................... 4 SDD22, Differential reflection loss ............................................................................................................. 5 SCD21, Differential to common mode conversion ....................................................................................... 6 SCD22, Differential to common mode reflection .......................................................................................... 7 SCD21-SDD21 ............................................................................................................................................. 8 Near end crosstalk (NEXT) .......................................................................................................................... 9 BER channel simulation ............................................................................................................................. 11
Document Number: PD-0098 Issue Date: August 31, 2011 Title: Signal Integrity Test Report Supersedes: New Subject: 3M™ External MiniSAS Cable Assembly Page: 2 of 14
3Electronic Solutions Division (PD-0098%20Ext%20MiniSAS%20SI%20Test%20Report[1].docx)
6801 River Place Blvd. Austin, TX 78726-9000 http://www.3Mconnectors.com
1.0 Scope This data sheet summarizes test methods, test conditions and product performance for the 3M Ribbon Twin Axial External MinSAS Cable Assemblies 2.0 Product Tested
Product: Ribbon Twin Axial External MiniSAS Cable Assembly
Product Number: 8G26 series; Assemblies tested S-parameters and NEXT: 8G26-0A-CW1-01-2.30 8G26-8A-CW1-01-5.00 BER channel simulation: 8G26-0A-CW1-01-1.00 8G26-8A-CW1-01-3.00 8G26-8A-CW1-01-5.00
Related Specification Sheet: TBD 3.0 General Conditions 3.1 Test Specimens The test specimens shall be strictly in compliance with the design, construction details and physical properties detailed in the relevant technical specification sheet (See Section 2). 3.2 Standard Test Conditions The test shall be done under the following conditions:
Temperature: 15°C to 35°C Relative Humidity: 45% to 75%
Atmospheric pressure: 650 to 800 mmHg
Document Number: PD-0098 Issue Date: August 31, 2011 Title: Signal Integrity Test Report Supersedes: New Subject: 3M™ External MiniSAS Cable Assembly Page: 3 of 14
3Electronic Solutions Division (PD-0098%20Ext%20MiniSAS%20SI%20Test%20Report[1].docx)
6801 River Place Blvd. Austin, TX 78726-9000 http://www.3Mconnectors.com
4.0 Test Results Summary
Items Specification per SAS2.1 rev07 Test Method Results Signal Integrity (Passive Cable)
Differential insertion loss, SDD21
Per SAS2.1 section 5.5.4: Loss less than TCTF test load specified in section 5.6.3 (see figure 93)
SAS-2.1 rev 07 sections 5.5.4, 5.6.3(figure 93) and Annex D.10
PASS
Differential reflection loss, SDD22
Meets SAS2.1 limit line: < -10 dB up to 2.08 GHz
< -7.9+13.3 x log( f / 3 GHz) between 2.08 and 6 GHz
SAS-2.1 rev 07 sections 5.5.4 and Annex D.10
PASS
Differential-to-common mode conversion, SCD21
Meets SAS2.1 limit line: < -18 dB up to 6 GHz
SAS-2.1 rev 07 sections 5.5.3 and Annex D.10
PASS
Differential to common mode reflection, SCD22
Meets SAS2.1 limit line: < -26 dB up to 300 MHz < -12.7+13.3 x log( f / 3 GHz) between 300 MHz and 4.78 GHz
< -10 dB between 4.78 and 6 GHz
SAS-2.1 rev 07 sections 5.5.3 and Annex D.10
PASS
SCD21 – SDD21; ( Differential-to-common mode conversion) minus ( Differential insertion loss)
Meets SAS2.1 limit line: < -10 dB up to 6 GHz
SAS-2.1 rev 07 sections 5.5.3 and Annex D.10
PASS
Near End Crosstalk (NEXT) Meets SAS2.1 limit line: < -26 dB up to 6 GHz
SAS-2.1 rev 07 section 5.5.3
PASS
BER channel simulation (Stateye)
Minimum eye height : 84 mV (P-P) Maximum total jitter: 0.64 UI
SAS-2.1 rev 07 section 5.5.5
PASS
Document Number: PD-0098 Issue Date: August 31, 2011 Title: Signal Integrity Test Report Supersedes: New Subject: 3M™ External MiniSAS Cable Assembly Page: 4 of 14
3Electronic Solutions Division (PD-0098%20Ext%20MiniSAS%20SI%20Test%20Report[1].docx)
6801 River Place Blvd. Austin, TX 78726-9000 http://www.3Mconnectors.com
5.0 Testing Test methods are based upon SAS-2.1 (T10/2125-D revision 07) 5.1 General Visual (Appearance) — EIA-364-18A Purpose The purpose of this test is to visually examine and dimensionally inspect the connector in order to determine whether the cable assembly conforms to the applicable specification and detail documents not covered by performance requirements. Test Method The examination shall be made in accordance with EIA-364-18A. The visual examination shall include inspection of the following features as a minimum: workmanship, marking, materials, finish, standards, design and construction. The dimensional inspection shall be a check for compliance with the outline drawings of the detail specification. 5.2 Signal Integrity Differential insertion loss, SDD21 Purpose The purpose of this test is to verify the differential insertion loss (SDD21) meets the requirements specified in SAS-2.1. Test Method Differential insertion loss (SDD21) has been measured in accordance with standard SAS-2.1 rev 07.
Document Number: PD-0098 Issue Date: August 31, 2011 Title: Signal Integrity Test Report Supersedes: New Subject: 3M™ External MiniSAS Cable Assembly Page: 5 of 14
3Electronic Solutions Division (PD-0098%20Ext%20MiniSAS%20SI%20Test%20Report[1].docx)
6801 River Place Blvd. Austin, TX 78726-9000 http://www.3Mconnectors.com
Differential reflection loss, SDD22 Purpose The purpose of this test is to verify the differential reflection loss (SDD22) meets the requirements specified in SAS-2.1. Test Method Differential reflection loss (SDD22) has been measured in accordance with standard SAS-2.1 rev 07.
‐30
‐25
‐20
‐15
‐10
‐5
0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
SDD21 ‐ Differential insertion loss
5M A23‐B23
5M A56‐B56
5M A89‐B89
5M A1112‐B1112
5M B23‐A23
5M B56‐A56
2.3M A23‐B23
2.3M A56‐B56
2.3M A89‐B89
2.3M A1112‐B1112
2.3M B23‐A23
2.3M B56‐A56
SDD21 limit line (TCTF)
Document Number: PD-0098 Issue Date: August 31, 2011 Title: Signal Integrity Test Report Supersedes: New Subject: 3M™ External MiniSAS Cable Assembly Page: 6 of 14
3Electronic Solutions Division (PD-0098%20Ext%20MiniSAS%20SI%20Test%20Report[1].docx)
6801 River Place Blvd. Austin, TX 78726-9000 http://www.3Mconnectors.com
Differential-to-common mode conversion, SCD21 Purpose The purpose of this test is to verify the differential-to-common mode conversion (SCD21) meets the requirements specified in SAS-2.1. Test Method Differential-to-common mode conversion (SCD21) has been measured in accordance with standard SAS-2.1 rev 07.
‐80
‐70
‐60
‐50
‐40
‐30
‐20
‐10
0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
SDD22 ‐ Differential return loss
5M A23‐B23
5M A56‐B56
5M A89‐B89
5M A1112‐B1112
5M B23‐A23
5M B56‐A56
2.3M A23‐B23
2.3M A56‐B56
2.3M A89‐B89
2.3M A1112‐B1112
2.3M B23‐A23
2.3M B56‐A56
SDD22 limit line
Document Number: PD-0098 Issue Date: August 31, 2011 Title: Signal Integrity Test Report Supersedes: New Subject: 3M™ External MiniSAS Cable Assembly Page: 7 of 14
3Electronic Solutions Division (PD-0098%20Ext%20MiniSAS%20SI%20Test%20Report[1].docx)
6801 River Place Blvd. Austin, TX 78726-9000 http://www.3Mconnectors.com
Differential to common mode reflection, SCD22 Purpose The purpose of this test is to verify the differential to common mode reflection (SCD22) meets the requirements specified in SAS-2.1. Test Method Differential to common mode reflection (SCD22) has been measured in accordance with standard SAS-2.1 rev 07.
‐120
‐100
‐80
‐60
‐40
‐20
0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
SCD21 ‐ Differential to common mode conversion
5M A23‐B23
5M A56‐B56
5M A89‐B89
5M A1112‐B1112
5M B23‐A23
5M B56‐A56
2.3M A23‐B23
2.3M A56‐B56
2.3M A89‐B89
2.3M A1112‐B1112
2.3M B23‐A23
2.3M B56‐A56
SCD21 limit line
Document Number: PD-0098 Issue Date: August 31, 2011 Title: Signal Integrity Test Report Supersedes: New Subject: 3M™ External MiniSAS Cable Assembly Page: 8 of 14
3Electronic Solutions Division (PD-0098%20Ext%20MiniSAS%20SI%20Test%20Report[1].docx)
6801 River Place Blvd. Austin, TX 78726-9000 http://www.3Mconnectors.com
SCD21 – SDD21 Purpose The purpose of this test is to verify the SCD21-SDD21 calculation meets the requirements specified in SAS-2.1. Test Method The components of the SCD21-SDD21 calculation, differential to common mode conversion (SCD21) and differential insertion loss (SDD21), have been measured in accordance with standard SAS-2.1 rev 07.
‐90
‐80
‐70
‐60
‐50
‐40
‐30
‐20
‐10
0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
SCD22 ‐ Differential to common mode reflection
5M A23‐B23
5M A56‐B56
5M A89‐B89
5M A1112‐B1112
5M B23‐A23
5M B56‐A56
2.3M A23‐B23
2.3M A56‐B56
2.3M A89‐B89
2.3M A1112‐B1112
2.3M B23‐A23
2.3M B56‐A56
SCD22 limit line
Document Number: PD-0098 Issue Date: August 31, 2011 Title: Signal Integrity Test Report Supersedes: New Subject: 3M™ External MiniSAS Cable Assembly Page: 9 of 14
3Electronic Solutions Division (PD-0098%20Ext%20MiniSAS%20SI%20Test%20Report[1].docx)
6801 River Place Blvd. Austin, TX 78726-9000 http://www.3Mconnectors.com
Near End Crosstalk (NEXT) Purpose The purpose of this test is to verify the near end crosstalk (NEXT) meets the requirements specified in SAS-2.1. Test Method Near end crosstalk (NEXT) has been measured in accordance with standard SAS-2.1 rev 07.
‐90.00
‐80.00
‐70.00
‐60.00
‐50.00
‐40.00
‐30.00
‐20.00
‐10.00
0.00
10.00
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
SCD21 ‐ SDD21
5M A23‐B23
5M A56‐B56
5M A89‐B89
5M A1112‐B1112
5M B23‐A23
5M B56‐A56
2.3M A23‐B23
2.3M A56‐B56
2.3M A89‐B89
2.3M A1112‐B1112
2.3M B23‐A23
2.3M B56‐A56
SCD21‐SDD21 limit line
Document Number: PD-0098 Issue Date: August 31, 2011 Title: Signal Integrity Test Report Supersedes: New Subject: 3M™ External MiniSAS Cable Assembly Page: 10 of 14
3Electronic Solutions Division (PD-0098%20Ext%20MiniSAS%20SI%20Test%20Report[1].docx)
6801 River Place Blvd. Austin, TX 78726-9000 http://www.3Mconnectors.com
‐140
‐120
‐100
‐80
‐60
‐40
‐20
0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
NEXT ‐ 2.3 meter ‐ A2/A3 victim
A56a ‐ A23v 2.3m
A89a ‐ A23v 2.3m
A1112a ‐A23v 2.3m
B23a ‐ A23v 2.3m
B56a ‐ A23v 2.3m
B89a ‐ A23v 2.3m
B1112a ‐ A23v 2.3m
Total NEXT
NEXT limit line
Document Number: PD-0098 Issue Date: August 31, 2011 Title: Signal Integrity Test Report Supersedes: New Subject: 3M™ External MiniSAS Cable Assembly Page: 11 of 14
3Electronic Solutions Division (PD-0098%20Ext%20MiniSAS%20SI%20Test%20Report[1].docx)
6801 River Place Blvd. Austin, TX 78726-9000 http://www.3Mconnectors.com
BER channel simulation Purpose The purpose of this test is to verify the BER channel simulation meets the requirements specified in SAS-2.1. Test Method The BER channel simulation has been conducted in accordance with standard SAS-2.1 rev 07. 1 meter (30 AWG)
‐120
‐100
‐80
‐60
‐40
‐20
0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
NEXT ‐ 2.3 meter ‐ A5/A6 victim
A23a ‐ A56v 2.3m
A89a ‐ A56v 2.3m
A1112a ‐A56v 2.3m
B23a ‐ A56v 2.3m
B56a ‐ A56v 2.3m
B89a ‐ A56v 2.3m
B1112a ‐ A56v 2.3m
Total NEXT
NEXT limit line
Document Number: PD-0098 Issue Date: August 31, 2011 Title: Signal Integrity Test Report Supersedes: New Subject: 3M™ External MiniSAS Cable Assembly Page: 12 of 14
3Electronic Solutions Division (PD-0098%20Ext%20MiniSAS%20SI%20Test%20Report[1].docx)
6801 River Place Blvd. Austin, TX 78726-9000 http://www.3Mconnectors.com
Eye height: 492 mV - PASS (> 0.84 mV) Jitter: 0.27 UI - PASS (< 0.64 UI)
3 meter (28 AWG)
Eye height: 360 mV - PASS (> 0.84 mV) Jitter: 0.30 UI - PASS (< 0.64 UI)
5 meter (28 AWG)
Document Number: PD-0098 Issue Date: August 31, 2011 Title: Signal Integrity Test Report Supersedes: New Subject: 3M™ External MiniSAS Cable Assembly Page: 13 of 14
3Electronic Solutions Division (PD-0098%20Ext%20MiniSAS%20SI%20Test%20Report[1].docx)
6801 River Place Blvd. Austin, TX 78726-9000 http://www.3Mconnectors.com
Eye height: 228 mV - PASS (> 0.84 mV) Jitter: 0.37 UI - PASS (< 0.64 UI)
Document Number: PD-0098 Issue Date: August 31, 2011 Title: Signal Integrity Test Report Supersedes: New Subject: 3M™ External MiniSAS Cable Assembly Page: 14 of 14
3Electronic Solutions Division (PD-0098%20Ext%20MiniSAS%20SI%20Test%20Report[1].docx)
6801 River Place Blvd. Austin, TX 78726-9000 http://www.3Mconnectors.com
Important Notice All statements, technical information, and recommendations related to 3M’s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M’s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of 90 days from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M’s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of the legal theory asserted. 3 Electronic Solutions Division Interconnect Products 6801 River Place Blvd. Austin, TX 78726-9000 U.S.A. 1-800-225-5373 www.3Mconnectors.com