Enter the network of expertiseThe Siemens Power Academy TD course catalogYour partner for Power Transmission, Distribution and Smart Grid training
Answers for infrastructure and cities.
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
2/92
E-mail: [email protected]
Web: siemens.com/poweracademy
2
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
3/92
Today, continuous change is the most important constant in the energy market.Urbanization, renewable energy and ambitious climate and environmental protectiongoals are the driving forces behind the constantly changing challenges. Challengesthat force us to upgrade our expertise on a regular basis because expertise isabsolutely crucial for ensuring a secure and reliable energy supply in the future.
Master these challenges together with the experts of the Siemens Power Academy TD.We are the specialists for training and continuing education on the subject of powertransmission and distribution, the industrial and commercial use of electric energy,and smart grid technology. We convey the expertise you need to constantly upgradeyour skills and knowledge, and thus lay the foundation for future success.
Our standard training courses are summarized for you in this catalog.Naturally, we also offer tailored training courses geared specifically to the goalsfor developing expertise in your company.
The courses of Siemens Power Academy TD impart valuable knowledge, boost yourproductivity, and strengthen your leadership potential. In short, theyre importantbuilding blocks for the active development of your career.
Get started on your path to a successful future
with training courses from Siemens Power Academy TD!
We look forward to welcoming you to our worldwide network of energy experts!
Your Siemens Power Academy
Enter the network of expertise
Welcome to the worldwidenetwork of energy experts!
3
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
4/92
Content
l Siemens Power Academy TD at a glance 10
Curricula
l Curriculum our competence development program 12l How to obtain certification 13
l SICAM PAS Substation Automation 14l SICAM RTUs Substation Automation 15
l SICAM 230 SCADA 16
l SIPROTEC Bay Controller 17l SIPROTEC Protection Service Power Transmission & Distribution(commissioning, operation, testing, maintenance) 18
l SIPROTEC Protection Service Power Generation and Industry(commissioning, operation, testing, maintenance) 19
l SIPROTEC Protection Planning Power Transmission & Distribution(planning, engineering, fault analysis 20l SIPROTEC Protection Planning Power Generation and Industry(planning, engineering, fault analysis) 21
Primary Technology
High Voltage
Fundamentals
l HV Circuit Breaker Testing 26l HV Overhead Transmission Line Design Fundamentals 24
l HV Primary Test Performing and Test Equipment 24
l HV Substation Design Basics 24l HV Switchgear Design Basics 24
l HV Switching Technology Introduction 24
l HVDC and FACTS Benefits of Power Electronics 23l HVDC and FACTS Workshop 24
Gas Insulated Switchgear (GIS)
l HV GIS Circuit Breaker Reyrolle Type SPD2 420 / 550 kV 25
l HV GIS Switchgear Reyrolle Type YG 420 / 550 kV 25
l HV Switching Technology GIS Technical Information 23
l Metal-Clad GIS Current 8D Product Range Operation and Maintenance Advanced 25l Metal-Clad GIS Current 8D Product Range Operation & Maintenance Intermediate 24
l Metal-Clad GIS Vintage Product Range Operation & Maintenance Intermediate 25
l Metal-Clad GIS Vintage Product Range Operation & Maintenance Advanced 25l Metal-Clad GIS Current Product Range Presentation 25
Circuit Breaker
l AIS Vintage SB6 Product Range Operation & Maintenance Intermediate 26l HV Switching Technology 3A 23
Air Insulated Switchgear (AIS)l AIS Current 3AP 3AQ Product Range Operation & Maintenance Intermediate 24
l HV AIS Circuit Breaker Reyrolle Type SPL2 420 / 550 kV 26
l Hydraulic Knowledge & Maintenance Fundamentals 25l Hydraulic Knowledge & Maintenance Intermediate 26l Metal-Clad GIS SF6Gas Handling & Associated Treatment Operations Advanced 27
l Upgrading Oil Circuit Breakers OP & MO Product Range Advanced 26l Vintage AIS Circuit Breakers FA Range with Hydraulic Operating Mechanism Operation & Maintenance Advanced 26
l Vintage AIS Circuit Breakers FA Range with Hydraulic Operating Mechanism Operation & Maintenance Intermediate 26
4
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
5/92
Medium Voltage
l LMV Power Supply Systems Process-Oriented Engineering 29l MV Assembly and Installation Training 28
l MV Cable Testing & Diagnostics 29
l MV Partial Discharges 29l MV Rural Electrification Techniques for Engineers & Technicians 28
l MV Assembly and Installation Training Refresher 29
l MV Circuit Breakers Maintenance 29l MV Equipments Certification Program for Operation & Maintenance 28
l MV Switchgear Maintenance 29
l MV Switchgear Technical Information Course (AIS & GIS) 27l MV Switching Devices & Switchgear Basics & Application 27
Low Voltage
l Design and Projection of Industrial Electrical Networks using the Software SIMARIS 29
Transformers
l Distribution Transformers Basics and Operation 30
l Distribution Transformers Grounding and Protection 30l Power Transformers Basics and Operation 30
l Transformers Integral Maintenance 30
l Transformers Lifecycle Management 30
General
l EHV, HV and MV Substations Overview: Arrangement, Protection,Control and Communication System 31l SF6European Certification Preparatory Course 31
l SF6Gas Awareness 31l SF6Gas Competence 31l Substation Condition Monitoring System Operation 31
l UHF Partial Discharge Monitoring for GIS Substations 31
5
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
6/92
Secondary Technology
Protection
Fundamentals
l Current and Voltage Transformers Intensive Course 39l Generator / Dynamics and Protection Workshop on a Real Time Digital Simulator RTDS 34l Protective Relaying Fundamentals 32
l Protection Systems Accessory Equipment 39
l Protection Technology Principles 32l System Protection Communication of Power Transmission and Distribution Networks 38
l System Protection Workshop on a Real Time Digital Simulator RTDS 32
SIPROTEC 4&5
l SIPROTEC Guided Exercises 39
l SIPROTEC 4 Application and Exercises 33l SIPROTEC 4 Application and Exercises of Generator / Motor Protection 36
l SIPROTEC 4 Busbar Protection 7SS52 34
l SIPROTEC 4 Distance Protection 7SA 35l SIPROTEC 4 HV Protection & Control 39
l SIPROTEC 4 Line Differential Protection 7SD 36
l SIPROTEC 4 Machine / Motor Protection 7UM & 7VE 35l SIPROTEC 4 MV Protection & Control 39
l SIPROTEC 4 Overcurrent and Motor Protection 7SJ 37
l SIPROTEC 4 Power System Protection Advanced 39l SIPROTEC 4 Power System Protection Basics 39
l SIPROTEC 4 Protection & Control System Engineering 39
l SIPROTEC 4 Protection Devices for Expert Engineers 33l SIPROTEC 4 Protection Devices for Service Engineers 33
l SIPROTEC 4 Protection Engineering Complete: 10 Days Certification Program 34
l SIPROTEC 4 Secondary Testing with OMICRON Test System CMC 38l SIPROTEC 4 Secondary Testing with OMICRON Tes t System CMC Advanced 39
l SIPROTEC 4 Secondary Testing with OMICRON Test System CMC Basics 39
l SIPROTEC 4 Transformer Differential Protection 7UT 37l SIPROTEC 4 Transformer Protection & Control 39
l SIPROTEC 5 Busbar Protection 7SS85 35
l SIPROTEC 5 Distance & Line Differential Protection 7SL 36l SIPROTEC 5 Overcurrent and Motor Protection 7SJ & 7SK 37
l SIPROTEC 5 Transformer Differential Protection 7UT 38
SIPROTEC Compactl SIPROTEC Compact (7SJ80, 7SK80, 7RW80, 7SD80) 38
SIGRAl Fault Record Analysis 38l SIGRA 4 Efficient Interpretation of Fault Records 40
DIGSI 4l DIGSI 4 Advanced 41
l DIGSI 4 Basics 40
l DIGSI 4 CFC 41l DIGSI 4 IEC 61850 and GOOSE Configuration 41
DIGSI 5
l DIGSI 5 Basics 41l DIGSI 5 CFC 42
l DIGSI 5 IEC 61850 and GOOSE Configuration 42
l DIGSI 5 Systems 42
Protection Schemes & Settings
l Generator / Motor Protection Design and Settings 40
l Protection of Oil and Gas Power Networks Part 1 43l Protection of Oil and Gas Power Networks Part 2 43
l Protection Schemes for Power Generation and Industry Design and Settings 40
l Transmission System Protection Schemes and Settings Calculation Practice 40l Transmission System Protection Schemes and Settings Calculation Practice Intensive 40
6
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
7/92
Substation Automation
SICAM PASl SICAM PAS Automation with CFC, ST and SFC 45
l SICAM PAS Basics 44
l SICAM PAS Complete 45l SICAM PAS Parameterization 44
l
SICAM PAS System Diagnosis and Trouble Shooting 45
l SICAM SCC Configuring an Operator Station 44
SICAM RTU
l Ax 1703 Workshop 49
l SICAM CMIC Smart Grid Solutions 48l SICAM EMIC WebParameterization 48
l SICAM RTUs Basics 46
l SICAM RTUs CAEx plus 47l SICAM RTUs Complete 47
l SICAM RTUs Engineering 46
l SICAM RTUs Power Week 47l SICAM RTUs Service 46
l SICAM RTUs Workshop Configuration & Commissioning SICAM 1703 Systems 49
l SICAM RTUs Workshop Configuration IEC 60870-5-101 / 104 Interface 49
l SICAM RTUs Workshop Configuration IEC 60870-5-103 Interface 48
l SICAM RTUs Workshop Configuration IEC 61850 Interface 48
l SICAM RTUs Workshop Configuration of SICAM BC 49l SICAM RTUs Workshop Configuration Profibus & Modbus Interfaces 49
l Substation Automation Equipments: 10 days Certification Program for Installation &Commissioning 48
SICAM 230
l SICAM 230 Configuration (latest version) 49l SICAM 230 Workshop Network Monitoring with SICAM 230 NWM 49l SICAM 230 Workshop Topology 49
Bay Controllerl SIPROTEC 4 Engineering of Bay Controllers 6MD66 with IEC 61850 GOOSE Communication 50
Telecontroll Telecontrol and Automation Fundamentals 50
Substation Information
l Communication Networks Application in Power Transmission & Distribution 51l IEC 61850 The Standard for Substation Automation 50
l IT Networks Basics 51
l IT Networks Automation 51l IT Security Basics 51
l IT Security Automation 51
l Numerical Communication in Substations Basics & Trends 51l Substation Automation Introduction 50
Power Quality
l Power Quality SICAM PQS and SICAM PQ Analyzer 52
l Power Quality in Industrial Networks 52
l SICAM Q80 Application and Practice 52l SIPROTEC 7KE85 Fault Recorder 52
7
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
8/92
Power System Engineering
Generall DEMS 3.0 Training for Technical Sales and Operations 53
l Division Smart Grid Technology at a Glance 53
l Division Smart Grid Technology at a Glance for Non Technical Employees 53l Power Transmission & Distribution Technology at a Glance 53
l
Siemens Energy Program for Graduates and Young Engineers (3 Months) 53Power Engineering
l Arc Flash Hazards Analysis and Risk Assessment 55l Electrical Energy Installations Basics 56l Industrial Power System Applications 56
l Medium and Low Voltage Installations Design Criteria 56l Oil and Gas Industry Fundamentals 56l Power Distribution Engineering Introduction 54
l Rail Fundamentals 55l Substation Engineering and Operations 55
l Transmission and Distribution Networks Basics Part I 54
l Transmission and Distribution Networks Basics Part II 54
Smart Grid
l
AMIS How it Works 57
l Electromobility Introduction and Status 57
l EnergyIP How it Works 57
l Smart Grid Introduction 56l Smart Metering Basis for Smart Grids 56
l The Energy & Smart Grid Series for Non-technical Professionals 57
Network Planningl Power System Planning Principles 57l Circuit Diagrams and Reference Systems Basics 59
l Dynamic Network Phenomena, Simulation and Analysis 59
l High and Low Voltage Installations Earthing and Interference 59l Low Voltage Networks Theory and Practical Applications 59
l Overvoltages and Insulation Coordination 59
l Power Distribution and Industry Networks System Planning and Quality 58
l Power Distribution Systems Reliability Analysis 59
l Power Distribution Systems Management and Automation Basics 59
l Power Flow Analysis with Applications Fundamentals 58l Power Flow Analysis with Applications Introduction 58
l Power System Reliability 59
l Power System Stability and Stabilizer Tuning 59l Power System Dynamics Basics 58
l Power System Dynamics Introduction 58
l Power Transmission & Distribution Systems Load Flow and Short Circuit Calculation 58
l Power Transmission Networks System Planning and Quality 58
Renewables Integration
l Distributed and Renewable Power Generation Integration 61
l Distributed Generation Energy Storage Applications on Power Systems 61l Wind Power Grid Connection Feasibility for Onshore Wind Farms 60
l Wind Power Introduction to Grid Compliance for Onshore Wind Farms 61l Wind power Network Integration 60l Wind Power Power System Studies for Integration 60
Building Technology
l Building Automation and Energy Efficiency 61
l Fire Detection New Technologies 61
8
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
9/92
Power System Simulation Software
PSSEl Power Electronics in Transmission Systems (PETS) 63
l PSSE Advanced Dynamic Simulation for PSSE 65
l PSSE Advanced Power Flow Using PSSE 62l PSSE Advanced Transmission Planning 66
l
PSSE Dynamic Simulation Using PSSE 64
l PSSE Fault Analysis 66l PSSE Integrating Renewables Using PSSE 63
l PSSE Model Writing for User Defined Models (UDMs) in PSSE 65
l PSSE Optimal Power Flow 64l PSSE Power Flow and Steady State Analysis Using PSSE 62
l PSSE Reactive Power Planning Using PSSE 62
l PSSE Transmission Reliability Studies Using PSSE 65l PSSE Using Python to Integrate PSSE Workflow 64
l PSSE Voltage Control and Reactive Power Planning Methods 63
PSSSINCAL
l PSSSINCAL Advanced for Distribution Companies 67l PSSSINCAL Basics 66
l PSSSINCAL Basics for Distribution Companies 67
l PSSSINCAL Dynamic Smart Grid Studies for Off-Grid Solutions 67l PSSSINCAL Protection Suite 66
l PSSSINCAL Smart Grid 67
PSSGeneral
l PSSMUST Using System Transmission Data for Decision Making 67
l PSSNETOMAC Advanced 67l PSSNETOMAC Basics 67
l Transient Analysis Using EMTP / ATP 67
Power System Operation
l Anti Disaster Training I Classic 50 Hz 68
l Electrical Power Issues in Nigeria for Bankers, Investors and Professionals 69
lMarket Operations and Power System Scheduling 68
l Power System Dynamics Stability and Oscillations 69
l SCADA System Spectrum Power CC Basic Level 69
l SCADA System Spectrum Power CC Intermediate Level 69l SIGUARD DSA Assessment of Power System Stability 69
l SIGUARD PDP Observation and Analysis of Power Systems with PMUs 69
l SIGUARD PSA Assessment of Protection Performance 69l Understanding System Losses for Utility Management 68
l Wide-Area Measurement Instrument-, Protection- and Control Technologyof the Future 69
Course Index per region 2014 70
9
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
10/92
Elevate your expertise to the next level:
Leading experts certified as trainers
Small groups of students
Practice-oriented training courses
Real-world relevance
High-quality, comprehensive course materials
Our offer
The Siemens Power Academy TD offers professionaltraining in the areas of power transmission anddistribution as well as industrial and commercialpower consumption, including smart grids.Siemens Power Academy TD has modern trainingcenters worldwide, with offices in Europe, the UnitedStates, South America, Asia, and Africa. Our objectiveis to provide our customers regardless of location with access to Siemens expert knowledge and capa-bilities. Move ahead of the competition by enteringour network of expertise! Thousands of participantsfrom more than 90 countries have benefited fromSiemens more than 160 years of global experience.
Certified trainersfrom Siemens businesses employthe latest teaching methods to guarantee you learnpractical skills quickly and retain what they learnover the long term.To offer a superior educational experience, we place
the utmost importance on ensuring ongoing qualitycontrol and constantly developing the qualityandcontent of our training program.Professionally prepared lecture notes, slides andcourse materialsensure that even after the trainingis complete, you will always have the key informa-tion at your fingertips.
Regular feedbackfrom our participants is a corecomponent of our quality control and the basis fora consistently high quality of continuing education.
Siemens Power Academy TD at a glanceOur goal is to broaden your skills and your knowledge for products, systems, fundamentals,
new technology and innovations in the area of power transmission and distribution.
Our strength: flexibility
Standard trainingThe ideal starting point: You benefit by learningalongside industry professionals from othercompanies on fixed dates for optimal cost-effectiveness.
Customized trainingMaximum personalization: You define thecontent, the product version and the time andlength of the sessions.
Practice-oriented workshopsFor advanced students: Expand your own basicknowledge of energy technology and learn to usespecific products and systems.
Training programs (Curricula)Certified knowledge: Follow an integrated conceptto systematically build up your expertise in threelevels (Associate, Advanced, Expert) and receivea certificate for each test you pass.
Combined technology and business learning
Highly practice-oriented: Interdisciplinary coursesare the ideal preparation for applying what youhave learned to your day-to-day work.
Personal consultationEvaluate your level of knowledge: We will helpyou assess where you are now and which trainingprogram will benefit you the most.
Training developmentFor curriculum development: We will provide youwith expert assistance in developing your ownworkshops.
1010
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
11/92
Our powerful portfolio
Siemens Power Academy TD offers you a comprehensivetraining program covering General Power Engineering,Primary and Secondary technology, Software tools aswell as various Smart Grid topics.In addition to our standard training portfolio, whichyou can find in this catalog, we also offer customizedtraining that will support you in all of your competencedevelopment needs. Please contact us and we will behappy to offer you more information.
Primary TechnologyMedium & High Voltage Technology, Transformers
Secondary TechnologyProtection, Substation Automation & Information, Power Quality
Power System EngineeringNetwork planning, Smart Grid, Renewable Integration
Power System Simulation SoftwarePSSE, PSSSINCAL
Power System Operation
Power Control Systems, Power System Security, Operation Management
Training portfolio of the Siemens Power Academy TD
Our core competence
The right mix of theory and practice
In the Siemens Power Academy TD training programs,theory and practice go hand-in-hand. This means thattheoretical approaches are always supplemented bypractical exercises on real devices and systems. To makethat possible, the training centers use original compo-nents, devices, and systems from the Transmission andDistribution product portfolio. This hands-on trainingprinciple guarantees a maximum learning effect.
11
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
12/92
Curriculum our competence development program
Well-trained employees are vital for successful companies. Challenges such as the rapid
transformation of economic, environmental and technological advancements require
employees to contiguously and systematical improve skills and knowledge. To be a reliable
resource and realize our potential, we all must take a personal stake in planning develop-
ment activities that will contribute to our personal and organizations success.
> 5 years
> 2 years
> 1 year
Professional experience
Qualification levels
Associate level
Advanced level
Expert level
Knowledge:Fundamental knowledgeabout the competencearea topic.
Practical experience:> 1 year project experiencein a position at least equalto that of project engineer.
Skills:Perform specific technicaltasks under supervision aspart of their professionalroutine.
Knowledge:Extended knowledge and
professional experience forindependently performingtasks in the competencearea.
Practical experience:> 2 years project experiencein a position at least equalto that of project engineer.
Skills:Independently performtasks as part of their profes-sional routine, and devel-oping required solutionsthemselves.
Knowledge:Extended knowledge andprofessional experience forindependently performingcomplex tasks based oncomprehensive professionalexperience.
Practical experience:> 5 years project experiencein a position at least equal
to that of project engineeror technical lead.
Skills:Independently performcomplex tasks as part oftheir professional routine,and also able to communi-cate complex relationshipsand solutions to projectengineers in the functionof technical lead.
To help you and your organization in thiseffort, Siemens Power Academy TD hasdesigned a competency-based develop-ment program to guide your learning plan.
In contrast to simply selecting individualtraining seminars, our curriculum providesyou with incremental learning through astructured, logical combination of classeson a specific topic. This allows the neces-sary skills and abilities to be systematicallydeveloped.
Each curriculum consists of a progressiveset of classes with three qualification
levels: Associate, Advanced, and Expert.Each level concludes with a learningassessment to ensure that the trainingwas successful.
We offer you a wide variety of curriculaincluding Protection Systems, SubstationAutomation, Power Systems Technology,Distribution Systems Technology, andPSS Network Planning and Analysis.
Please visit our website for an overviewof our selection of curricula:
siemens.com/poweracademy/curricula
12
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
13/92
How to obtain certification
Step 1
Selection of the required curriculum and qualification level
Students and supervisors review and select the curriculum content and define the required qualificationlevel. Siemens Power Academy TD is happy to assist with this process.
Now you are ready to choose your classes. To register for a class, please visitwww.siemens.com/poweracademy or contact your regional training center for assistance in bookingyour training.
Step 2
Participation in training
Students attend all required classes. The order of courses within a qualification level is a recommendation only, and can be altered by the trainee.
Step 3
Testing
Students register for and complete all tests for the selected level of the required curriculum The test can be completed online. Students who pass the e-test each certification programs has a minimum achievement levels for e-tests.The qualification certificate can be printed out after the e-test.
If the student is not able to achieve the required passing grade on their first attempt, they can contact
their regional training center to re-test or re-take the course.
Step 4
Certification
Once the student have completed the requirements for the certification, complete the certificate applicationform for a final evaluation. Siemens Power Academy TD staff members are available to assist.
If all the criteria for the curriculum certification have been met, Siemens Power Academy TD issuesthe certificate. Product and software-based certifications are valid for a specified period of time beforerefresher courses are required for certification maintenance.
13
Our curricula
l
SICAM PAS Substation Automation
l
SICAM RTUs Substation Automation
l
SICAM 230 SCADA
lSIPROTEC Bay Controller
lSIPROTEC Protection Service Power Transmission & Distribution
(commissioning, operation, testing, maintenance)l
SIPROTEC Protection Service Power Generation and Industry
(commissioning, operation, testing, maintenance)
l
SIPROTEC Protection Planning Power Transmission & Distribution
(planning, engineering, fault analysis)
lSIPROTEC Protection Planning Power Generation and Industry
(planning, engineering, fault analysis)
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
14/92
Associate Advanced Expert Recommended
e-test Courses can be ordered at: www.siemens.com/poweracademy
Curriculum
SICAM PAS Substation Automation (CU-PASE)
Telecontrol and Automation Fundamentals
DIGSI 4 IEC 61850 and GOOSE Configuration
SICAM SCC Configuring an Operator Station
DIGSI 4 Basics
Booking code SAS-TELE
Booking code DIGSI4-I
Booking code PAS-S
e-test WT-PASC
Booking code DIGSI4-B
SICAM PAS Basics
SICAM PAS Parameterization
Associate
Booking code PAS-B
e-test WT-PASB
Booking code PAS-P
e-test WT-PASP
SICAM PAS Automation with CFC, ST and SFC
IT Networks Automation
SIPROTEC 4 Engineering of Bay Controllers 6MD66
with IEC 61850-GOOSE Communication
DIGSI 4 Advanced
Booking code PAS-C
Booking code SIT-NETW2
Booking code SIP4-6MD66
Booking code DIGSI4-A
IT Networks Basics
IT Security Basics
Booking code SIT-NETW1
Booking code SIT-SECUR1
e-test WT-SECUR1
e-test WT-PASC
e-test WT-DIGSI4I
e-test WT-6MD66
e-test WT-DIGSI4A
Advanced
SICAM PAS System Diagnosis and Trouble Shooting
IT Security Automation
IT Networks Automation
IT Networks Basics
Booking code PAS-SYS
Booking code SIT-SECUR2
Booking code SIT-NETW2
Booking code SIT-NETW1
e-test WT-PASSYS
e-test WT-SECUR2
e-test WT-NETW2
e-test WT-NETW1
Expert
14
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
15/92
Associate Advanced Expert Recommended
e-test Courses can be ordered at: www.siemens.com/poweracademy
SICAM RTUs Workshop Configuration IEC 60870-5-101/104Interface
SICAM RTUs Engineering
DIGSI 4 Basics
Telecontrol and Automation
Fundamentals
Booking code RTU-IEC104
Booking code RTU-ENG
e-test WT-RTUENG
Booking code DIGSI4-B
Booking code SAS-TELE
SICAM RTUs Service
SICAM RTUs Basics
SICAM RTUs CAEx Plus
Associate
Booking code RTU-SERVIC
Booking code RTU-BASIC
e-test WT-RTUSER
e-test WT-RTUBAS
Booking code RTU-CAEX
e-test WT-RTUCAEX
IT Security Basics
IT Networks Automation
SICAM RTUs Workshop
Configuration IEC 61850 Interface
DIGSI 4 IEC 61850 and GOOSE Configuration
Booking code SIT-SECUR1
Booking code SIT-NETW2
Booking code RTU-IEC61
Booking code DIGSI4-I
IT Networks Basics
SICAM RTUs Workshop Configuration Profibus & ModbusInterfaces
DIGSI 4 Advanced
IT Security Automation
Booking code SIT-NETW1 Booking code RTU-MODBUS
Booking code DIGSI4-A
Booking code SIT-SECUR2
e-test WT-SECUR2
e-test WT-SECUR1
e-test WT-IEC104
e-test WT-IEC61
e-test WT-DIGSI4I
Advanced
SICAM RTUs System Diagnosis and Troubleshooting
IT Networks Automation
IT Networks Basics
Booking code RTU-SYS
Booking code SIT-NETW2
Booking code SIT-NETW1
e-test WT-RTUSYS
e-test WT-NETW2
e-test WT-NETW1
Expert
SICAM RTUs Substation Automation (CU-RTUE)
15
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
16/92
Associate Advanced Expert Recommended
e-test Courses can be ordered at: www.siemens.com/poweracademy
Curriculum
SICAM 230 SCADA (CU-230E)
Telecontrol and Automation Fundamentals
SICAM 230 Workshop Topology
SICAM 230 Configuration (latest version)
SICAM RTUs Basics
Booking code SAS-TELE
Booking code 230-TOP
Booking code 230-CONFI
e-test WT-230CONF
Booking code RTU-BASIC
SICAM TOOLBOX II Basics
Associate
Booking code TOOLBOX
e-test WT-TOOLBOX
IT Security Basics
IT Networks Basics
IEC 61850 The Standard for Substation Automation
Booking code SIT-SECUR1
Booking code SIT-NETW1
Booking code SIT-IEC
IT Networks Automation
IT Security Automation
Booking code SIT-NETW2
Booking code SIT-SECUR2
e-test WT-SECUR2
e-test WT-SECUR1
Advanced
IT Networks Automation
IT Networks Basics
SICAM 230 Workshop Network Monitoringwith SICAM 230 NWM
Booking code SIT-NETW2
Booking code SIT-NETW1
Booking code 230-MONIT
e-test WT-NETW2
e-test WT-NETW1
e-test WT-230MONI
Expert
16
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
17/92
Associate Advanced Expert Recommended
e-test Courses can be ordered at: www.siemens.com/poweracademy
SIPROTEC Bay Controller (CU-BAYE)
SIPROTEC 4 Engineering of Bay Controllers 6MD66with IEC 61850-GOOSE Communication
Booking code SIP4-6MD66
e-test WT-6MD66
DIGSI 4 Basics
Associate
Booking code DIGSI4-B
e-test WT-DIGSI4B
Communication Networks Application in Power Transmission& Distribution
Booking code SIT-COMPT
DIGSI 4 IEC 61850 and GOOSE Configuration
Booking code DIGSI4-I
e-test WT-DIGSI4I
e-test WT-SITCOMP
Advanced
SICAM PAS Parameterization
DIGSI 4 CFC
Booking code PAS-P
Booking code DIGSI4-C
e-test WT-PASP
e-test WT-DIGSI4C
Expert
17
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
18/92
Associate Advanced Expert Recommended
e-test Courses can be ordered at: www.siemens.com/poweracademy
Curriculum
SIPROTEC Protection Service Power Transmission & Distribution(commissioning, operation, testing, maintenance) (CU-SIPTDCE)
Transmission and Distribution Networks Basics Part II
Transmission and Distribution Networks
Basics Part I
SIPROTEC 4 Secondary Testingwith OMICRON Test System CMC
SIPROTEC 4 Application and Exercises
SIPROTEC Guided Exercises
Booking code PE-TDNET2
Booking code PE-TDNET1
Booking code SIP4-CMC
Booking code SIP4-SYS
e-test WT-SIP4SYS
Booking code WS-GUIDE
DIGSI 4 Basics
Protection Technology Principles
Associate
Booking code DIGSI4-B
Booking code PR-PRIN
e-test WT-DIGSI4B
e-test WT-PRPRIN
Protection Systems Accessory Equipment
SIPROTEC 4 Overcurrent and Motor Protection 7SJ
DIGSI 4
Advanced
SIPROTEC 4 Busbar Protection 7SS52
SIGRA 4 Efficient Interpretation of Fault Records
Booking code SIP4-ACCES
Booking code SIP4-7SJ
Booking code DIGSI4-A
Booking code SIP4-7SS
Booking code SIP4-SIGRA
Current and Voltage Transformers Intensive Course
DIGSI 4 IEC 61850 and GOOSE Configuration
Booking code SIP-VTI
Booking code DIGSI4-I
e-test WT-DIGSI4I
e-test WT-SIP4ACC
e-test WT-SIP4CMC
Advanced
SIPROTEC 4 Line Differential Protection 7SD
SIPROTEC 4 Transformer Differential Protection 7UT
SIPROTEC 4 Distance Protection 7SA
Booking code SIP4-7SD
Booking code SIP4-7UT
Booking code SIP4-7SA
e-test WT-SIP47SD
e-test WT-SIP47UT
e-test WT-SIP47SA
Expert
18
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
19/92
Associate Advanced Expert Recommended
e-test Courses can be ordered at: www.siemens.com/poweracademy
SIPROTEC Protection Service Power Generation and Industry(commissioning, operation, testing, maintenance) (CU-SIPGICE)
Transmission and Distribution Networks Basics Part II
Transmission and Distribution Networks Basics Part I
SIPROTEC 4 Secondary Testingwith OMICRON Test System CMC
Protection Technology Principles
DIGSI 4 Basics
SIPROTEC Guided Exercises
Booking code PE-TDNET2
Booking code PE-TDNET1
Booking code SIP4-CMC
Booking code PR-PRIN
Booking code DIGSI4-B
e-test WT-PRPRIN
e-test WT-DIGSI4B
Booking code WS-GUIDE
SIPROTEC 4 Application and Exercises
Associate
Booking code SIP4-SYS
e-test WT-SIP4SYS
SIPROTEC 4 Application and Exercisesof Generator/Motor Protection
DIGSI 4 Advanced
Protection Systems Accessory Equipment
SIPROTEC 4 Distance Protection 7SA
SIPROTEC 4 Line Differential Protection 7SD
SIPROTEC 4 Overcurrent and Motor Protection 7SJ
SIGRA 4 Efficient Interpretation of Fault Records
Booking code SIP4-GEN
Booking code DIGSI4-A
Booking code SIP4-ACCES Booking code SIP4-7SA
Booking code SIP4-7SD
Booking code SIP4-7SJ
Booking code SIP4-SIGRA
Current and Voltage Transformers Intensive Course
DIGSI 4 IEC 61850 and GOOSE Configuration
Booking code SIP-VTI
Booking code DIGSI4-I
e-test WT-DIGSI4I
e-test WT-SIP4GEN
e-test WT-SIP4CMC
Advanced
SIPROTEC 4 Machine/Motor Protection 7UM & 7VE
SIPROTEC 4 Busbar Protection 7SS52
SIPROTEC 4 Transformer Differential Protection 7UT
Booking code SIP4-7UMVE
Booking code SIP4-7SS
Booking code SIP4-7UT
e-test WT-7UMVE
e-test WT-SIP47SS
e-test WT-SIP47UT
Expert
19
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
20/92
Associate Advanced Expert Recommended
e-test Courses can be ordered at: www.siemens.com/poweracademy
Curriculum
SIPROTEC Protection Planning Power Transmission & Distribution(planning, engineering, fault analysis) (CU-SIPTDPE)
Transmission and Distribution Networks Basics Part II
Transmission and Distribution Networks
Basics Part I
Current and Voltage Transformers Intensive Course
SIPROTEC 4 Application and Exercises
SIPROTEC Guided Exercises
Booking code PE-TDNET2
Booking code PE-TDNET1
Booking code SIP-VTI
Booking code SIP4-SYS
e-test WT-SIP4SYS
Booking code WS-GUIDE
DIGSI 4 Basics
Protection Technology Principles
Associate
Booking code DIGSI4-B
Booking code PR-PRIN
e-test WT-DIGSI4B
e-test WT-PRPRIN
DIGSI 4 IEC 61850 and GOOSE Configuration
SIGRA 4 Efficient Interpretation of Fault Records
Dynamic Network Phenomena, Simulation and Analysis
Booking code DIGSI4-I
Booking code SIP4-SIGRA
Booking code NET-DYNAM
DIGSI 4 CFC
Transmission System Protection Schemes and Settings CalculationPractice
Booking code DIGSI4-C
Booking code PR-DSPS
e-test WT-PRDSPS
e-test WT-DIGSI4I
e-test WT-SIPVTI
Advanced
Transmission System Protection Schemes and Setting CalculationPractice Intensive
System Protection Workshop on a Real TimeDigital Simulator RTDS
Communication Networks Application in Substations
Booking code PR-DSPSI
Booking code RTDS-PS
Booking code SIT-COMSUB
e-test WT-PRDSPSI
e-test WT-RTDSPS
e-test WT-SITCOMS
Expert
20
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
21/92
Associate Advanced Expert Recommended
e-test Courses can be ordered at: www.siemens.com/poweracademy
SIPROTEC Protection Planning Power Generation and Industry(planning, engineering, fault analysis) (CU-SIPGIPE)
Transmission and Distribution Networks Basics Part II
Transmission and Distribution Networks Basics Part I
Current and Voltage Transformers Intensive Course
Protection Technology Principles
DIGSI 4 Basics
SIPROTEC Guided Exercises
Booking code PE-TDNET2
Booking code PE-TDNET1
Booking code SIP-VTIBooking code PR-PRIN
Booking code DIGSI4-B
e-test WT-PRPRIN
e-test WT-DIGSI4B
Booking code WS-GUIDE
SIPROTEC 4 Application and Exercises
Associate
Booking code SIP4-SYS
e-test WT-SIP4SYS
DIGSI 4 IEC 61850 and GOOSE Configuration
Dynamic Network Phenomena, Simulation and Analysis
SIGRA 4 Efficient Interpretation of Fault Records
Booking code DIGSI4-I
Booking code NET-DYNAM
Booking code SIP4-SIGRA
DIGSI 4 CFC
Protection Schemesfor Power Generation & Industry Design & Settings
Booking code DIGSI4-C
Booking code PR-DSIN
e-test WT-PRDSIN
e-test WT-DIGSI4I
e-test WT-SIPVTI
Advanced
Generator/Dynamics and Protection Workshop on a Real TimeDigital Simulator RTDS
Generator/Motor Protection Design & Settings
Communication Networks Application in Substations
Booking code RTDS-GEN
Booking code PR-DSMP
Booking code SIT-COMSUB
e-test WT-RTDSGEN
e-test WT-PRDSMP
e-test WT-SITCOMS
Expert
21
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
22/92
Part of a curriculum;e-test required for the certificate
Explanation of symbols
Country Language Duration / no. of days
Booking information
MLFB-Number
Price:
The Siemens Power Academy TD portfolio consists of five main training categories:Primary Technology, Secondary Technology, Power System Engineering,Power System Simulation Software and Power System Operation.For most of the courses you will find detailed information on learning objectives, content,and target audiences as well as prerequisites that participants should have in order to getmaximum benefit from the training.Additional courses are listed with brief descriptions.For more details on these as well as other courses, please visit our Web site at:siemens.com/poweracademy.We are pleased to support you in your professional development,and to help you determine which training courses will be of the greatest value to you.
We look forward to meeting you at one of our training sessions!
Contact details:
Germany:E-mail: [email protected]: +49 911 433 7415
Further local contact details you will findon page number 90.
Siemens Power Academy TD Our course portfolio
AR = ArgentinaAT = AustriaBR = BrazilCO = ColombiaDE = GermanyES = SpainFR = FranceGB = United Kingdom
IN = IndiaMX = MexicoNG = NigeriaNL = NetherlandsNO = NorwayRU = RussiaTR = TurkeyUS = United States
de = Germanen = Englishes = Spanishfr = Frenchnl = Dutchno = Norwegianpt = Portugueseru = Russiantr = Turkish
USA:E-mail: [email protected]: +1 518 395 5005
22
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
23/92(Net prices)
HVDC and FACTS Benefits of Power Electronics
Booking code:HVDC/FACTS
Training objectives
The participant will understand power electronicsin high voltage and medium voltage systems with
a focus on HVDC and FACTS and their applications.Information on the technical features of differentsolutions, HVDC and FACTS system behavior,design of components, operation and mainte-nance requirements will be given.
Target audience
Engineers and managers in utilities, administra-tion, transmission companies, power producers,consultants, design institutes and equipmentmanufactures who are responsible for sales andmarketing, consulting, planning and design oftransmission projects, and all technically interestedpeople in general.
Prerequisites
Basic knowledge of electrical and powerengineering.
Main features
Trends in power systems Understanding power transmission Power quality terms and definitions Trends in AC and DC transmission Introduction in power electronic solutions HVDC and FACTS basics and trends VSC Technology for HVDC, FACTS and tractions
supplies Power electronics for distributions and
industrial systems Costs of high voltage transmission
Projects, studies and applications Outlook: PEBBs, GIS / HIS, GIL, H 2 and HTSC Training on computer and real-time simulator Blackouts 2003 Lessons Learned?
9CA4110-0NE00-0DF7DE en 4
2,300 EUR
HV Switching Technology GIS Technical Information
Booking code:HV-GIS
Training objectives
By covering the most important technical knowl-edge on high voltage gas-insulated switchgear,
the participants will be able to describe possiblefaults on SF6-insulated switchgear and to establishtheir causes.
Target audience
Persons who participate, should be familiar withdesign and construction of SF6-insulated switch-gear, e.g. operating and maintenance personnel,field service personnel and engineers.
Prerequisites
Knowledge of switchgear technology would bean advantage.
Main features
Conveying detailed knowledge of the
technology of specific switchgear types 8D-type
The following points are discussed in particular: The different types of switchgear Mode of operation / Setup / Arrangement
of the individual modules Basic mode of operation of the circuit-
breaker interrupter unit The basic mode of operation of the spring
drive system Control and monitoring of the switchgear (The limit values and background) The interlocking system of the modules Maintenance and service aspects of the
Switchgear
Environmental protection aspects of SF6
9CA4130-0HE00-0DA3DE en 4
2,300 EUR
MX es 5139,320 MXN
High Voltage
HV Switching Technology 3A
Booking code:HV-3A
Training objectives
By covering the most important technical knowl-edge on high voltage gas-insulated switchgear(Type 3A), the participate will be able to describepossible faults on SF6-insulated switchgear andto establish their causes.
Target audience
Persons who, should be familiar with design andconstruction of power circuit-breakers, e.g. oper-ating and maintenance personnel, field servicepersonnel and engineers.
Prerequisites
Major knowledge of power engineering.Experience with switchgear technology wouldbe advantageous.
Main features
Conveying detailed knowledge of thetechnology of specific circuit-breakers
(3AP1, 3AQ, 3AT) The individual modules of the switchgear Interaction of the individual modules Basic mode of operation of the circuit-breaker
interrupter unit The basic mode of operation of the drive
system Control and monitoring of the switchgear The limit values and background The interlocking system Maintenance and servicing Environmental protection
9CA4130-0HE00-0DA4DE en 5
2,900 EUR
MX es 5139,320 MXN
23
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
24/92
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
25/92
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
26/92
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
27/92(Net prices)
MV Switchgear Technical Information Course(AIS & GIS)
Booking code:MV-INFO
Training objectives
The training provides information on switchgearand devices in the primary and secondary distri-
bution level. It gives the main technical knowl-edge of operational and personal safety andmaintenance. On the basis of exhibits handlingand locking concepts of dif ferent designs aredemonstrated for air and gas insulated switchgear.
Target audience
Planning, operation and service personnel fromutilities and industries.Interested parties from sales and projectprocessing.
Prerequisites
Basic technical knowledge (medium voltage).
Main features
Primary and secondary distribution Circuit breakers and other devices in medium
voltage switchgear Air and gas insulated switchgear Design and Classification (IEC 62271) Personal and operational safety Testing, maintenance and service Practical exercises on switchgear panels Factory tour Schaltwerk Frankfurt
(for courses in Germany)
Notes
The training program can also be tailored to specialcustomer needs if requested.
9CA4130-0ME00-0DA1 DE en 31,700 EUR
MX es 368,580 MXN
NG en 3150,000 NGN
US en 21,825 USD
MV SwitchingDevices & Switchgear Basics & Application
Booking code:MV-SWITCH
Training objectives
The participant will be familiarized with selection,functions, standards and planning criteria of
medium voltage switching devices and switch-gear.
Target audience
Technical staff involved in sales and project plan-ning for power distribution systems up to 36 kV.
Prerequisites
Basic technical knowledge. Electrotechnicalknowledge will be of advantage.
Main features
Electrical power supply Customer applications Components of switchgear
Task
Function Rated values Switching duties Standards Planning of switchgear Building specification and personal safety Design of switchgear Product portfolio
9CA4130-0ME00-0DA2DE en 2
1,100 EUR
MX es 368,580 MXN
IN en 210,000 INR
US en 21,825 USD
Metal-Clad GIS SF6Gas Handling & AssociatedTreatment Operations Advanced
Booking code:SF6-GIS
Training objectives
Acquisition of advanced level in the treatmentoperations of the SF6compartments of highvoltage metal-clad equipment. The trainee willbe capable of executing gas filling and recoveryoperations on high voltage switching devicesdepending on specific SF6handling requirements,in compliance with the regulations in force.
FR en 3Price on request
FR es 3Price on request
FR fr 3Price on request
High Voltage Medium Voltage
27
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
28/92(Net prices)
Medium Voltage
MV Rural Electrification Techniquesfor Engineers & Technicians
Booking code:MV-RURAL
Training objectives
The participants will gain knowledge of thecommissioning and maintenance of distribution
transformers, their cooling methods and blockdistribution stations. They will be able to, identify,use and maintain different types of cables, carryout cable jointing and cable termination, conducttests on cables, carry out installation earthing.They will be able to install, commission andmaintain basic supply and lighting units usingPhotovoltaic.
Target audience
Engineers, junior engineers, field personal andtechnicians involved in operation, planning, design,maintenance and servicing of rural electrificationsystems.
Prerequisites
Basic knowledge of electrical engineering.
Main features
Transformer installation and maintenance, Block distribution stations / Ring Main Units
(including different types of switchgear) Cable splicing and termination System and installation earthing Photo voltaic power supply and lighting units
NG en 10525,000 NGN
MV Assembly andInstallation Training
Training objectives
The training imparts profound knowledge aboutthe layout, operation, installation and attendance
(current state control) in the primary parts of theaccording switchgear. After successful completionof the course, the participants receive a certificatethat authorizes them to work self-responsibly onswitchgears (primary parts).
Target audience
Assembly and installation staff.
Prerequisites
Basic knowledge of assembly technique.Since the assembly and installation trainingincludes active learning components, the partici-pants must wear suitable working clothes andsafety shoes.
Main features Theory (ratings, typicals, layout, circuit-breaker
modules, switches) Operation (Operator controls, drive mechanism,
operating procedures, interlocks) Installation (installation of panel / block
interconnecting equipment, busbar installation;installation of the voltage transformer
We offer trainings for the following switchgears: NXAIR World (MV-NXAIRW) NXAIR M World (MV-NXAIRM) NXPLUS C (MV-NXPLUSC) NXPLUS (MV-NXPLUS) 8DA / B10 (MV-8DA8DB)
8DJ10 (MV-8DJ10) 8DH10 (MV-8DH10) 8DJH (MV-8DJH) SIMOSEC (MV-SIMOSEC) 8BT1 (MV-8BT1) 8BT2 (MV-8BT2) 8BT3 (MV-8BT3) SIMOPRIME World (MV-SIMOPRI)
Notes
This certificate is valid for 3 years. The certifica-tion of gas insulated switchgear is only availablein Germany, and air insulated switchgear only inTurkey.
CO es 14Price on request
DE en 14Price on request
IN en 14Price on request
TR en 14Price on request
TR tr 14Price on request
MV Equipments Certification Program forOperation & Maintenance
Booking code:MV-CERTIF
Training objectives
The participants will be familiarized with selection,engineering, operation and maintenance of medi-
um voltage switchgear and power transformers.
Target audience
Supervisors, engineers, field personal, techniciansand specialists involved in operation, planning,design, maintenance and servicing of switchgear,transformers and protecting equipments fromelectric utilities and the industrial sector.
Prerequisites
Basic knowledge of electrical engineering andfirst relevant exposure to MV equipments.
Main features
Technical information course for mediumvoltage switchgear and switching equipments:
selection, planning and design functions,locating and rectifying faults, safetyregulations, handling of SF6gas
Technical information course for operatingpersonnel-power transformers: selection,planning and design functions, assembly andinspection, safety regulations
Medium voltage switchgear NXPLUSC, 8DA,operation and maintenance: fundamentalfunctions and characteristics, installation,operation and maintenance of breakingdevises, etc.
Power and distribution transformer technicalworkshop: operation and maintenance
Technical workshop-life cycle management
Protection of transformers
NG en 10525,000 NGN
28
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
29/92(Net prices)
LMV Power Supply Systems Process-Oriented Engineering
Booking code:LMV-ENG
Training objectives
This course conciliates a basic knowledge ofpower systems and systems engineering enabling
participants to work out reliable and cost-effectivesolutions to problems that are encountered inindustrial processes.
9CA4130-0ME00-0DA3DE en 3
1,700 EUR
MV Partial Discharges
Booking code:MV-PARTIAL
Training objectivesIn this theoretical - practical course, the participantswill acquire the necessary knowledge for perform-ing partial discharge test, as well as understandingbasic concepts necessary for interpretation andanalysis of the results obtained in the tests, tendingto the development of a suitable diagnosis ofequipment condition.
CO es 21,080,000 COP
MV Circuit Breakers Maintenance
Training objectives
The participants will learn about the execution ofmaintenance measures for the circuit breaker. Aftera successful participation the trainee receives acertificate of attendance to work self-dependentand is able to execute the necessary maintenanceoperations (revisions, visual checks, etc).
We offer trainings for the followingcircuit breakers:
H515 / 3AB / 3AC (MV-3AB / C) 3AH / 3AJ / 3AK (MV-3AH / J / K) 3AF / 3AG / 3CG (MV-3AF / G)
DE en ?Price on request
MV Assembly andInstallation Training Refresher
Training objectives
This training offers knowledge about the mostup-to-date development of different switchgears:
NXPLUS C (MV-RPLUSC) NXPLUS (MV-RPLUS) 8DA / B10 (MV-R8DAB10)
DE en 1Price on request
MV Cable Testing & Diagnostics
Booking code:MV-CABLE
Training objectivesIn this theoretical - practical course, the participantswill acquire the necessary knowledge for perform-ing diagnostic cable tests, as well as understandingbasic concepts necessary for interpretation andanalysis of the results obtained in the tests andlocating incipient faults.
CO es 21,080,000 COP
MV Switchgear Maintenance
Training objectives
The participants receive a fundamental trainingcourse in our training centers or directly on-site,
especially created for your circuit breaker installa-tion.
Target audience
The training course is designed for maintenancetechnicians, technical department foremen andengineers.
Prerequisites
Technical fundamental knowledge in operationof switchgears.
Main features
Switchgear: Ratings, typicals, layout Operator controls, drive mechanism,
operating procedures General visibility control of circuit breakers Mechanical and electronical function control
Verification of circuit breakers and its driver Control of all bolted connections and ist
contact system Lubrication according to operating
instructions Recognizing damaged drive components
Substation: Rotational maintenance work according
to manufacturer information
Notes
This course is arranged according to your
switchgear devices and previous knowledge.Please contact us!
DE en ?Price on request
Design and Projectionof Industrial Electrical Networks
using the Software SIMARIS
Booking code:SIMARIS
Training objectives
On completion of the compact training, the partic-ipant will acquire a sounding overview of powerengineering in theory & practise and the expertiserequired to plan, engineer and dimension powersystems and networks. He will gather informationon the structure of an industrial power network.He will understand the different equipments andsystems present in typical industry network, theirdimensioning and calibration / setting. Using theSimaris software, he will exercise examples of true
life situation in regard of planning of networksand dimensioning of power equipment. Aside thetechnical aspects of the planning, he will under-stand the financial implications of its planning onthe operation and the management of the powersystems. The practical Session (using Simaris)will enable to familiarize with Siemens por tfolio(product range and specification) as in regard ofproducts and systems used for power distribution.
NG en 5300,000 NGN
29
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
30/92(Net prices)
Transformers
TransformersLifecycle Management
Booking code:TR-TLM
Training objectives
Participants are provided with an overview ofdiverse diagnostics possibilities, monitoring
systems and measures for prolonging the lifeof power transformers. Aging phenomena aredescribed on the basis of chemical and physicalprinciples and possibilities of intervening in theprocesses are discussed. The areas of use ofexisting maintenance processes are assessedin connection with the results of diagnosis.
CO es 3
1,560,000 COP
TransformersIntegral Maintenance
Booking code:TR-MAIN
Training objectives
The training conveys general and special knowl-edge required for the safe operation of powertransformers, maintenance works and early faultdetection.
CO es 3
1,560,000 COP
Power Transformers Basics and Operation
Booking code:TR-PT
Training objectives
This course supplies a further understanding of atransformer. Presentations, training exercises and
experiments carefully illustrate the characteristicproperties of transformers, examples on powertransformers (LPT, MPT).
Target audience
Employees who would like to be informed aboutfurther knowledge of functionality and operationof a transformer.
Prerequisites
Basic knowledge of electrical engineering.Fundamentals of AC and DC circuits.Extended knowledge to measuring electricalvariables.
Main features
1. General transformer overview Transformers and reactors in transmission and
distribution networks final exercises Transformer technology
Advanced electrical design, measuringwinding resistance and no load response
Autotransformers Vector groups Advanced electrical design, response under
load condition Short circuit characteristics Efficiency and transformer loss Measuring on different vector groups
2. Transformer components Voltage regulation with tap changers
final questions Cooling equipment, troubleshooting using
circuit diagrams Working with control and protection devices
3. Transformer in service Safety policies final questions Installing
Oil analysis Oil filling
Commissioning Insulation tests Dielectric tests
Maintenance and troubleshooting Inspection tasks Advanced condition assessment and fault
scenarios Overload and emergency operation
9CA4130-0TE00-0DA5DE en 3
1,750 EUR
Distribution Transformers Basics and Operation
Booking code:TR-DT
Training objectives
This course supplies a basic understanding ofa transformer. Presentations, training exercises
and experiments carefully illustrate the charac-teristic properties of transformers, examples ondistribution transformers (DT).
Target audience
Employees who would like to be informed aboutgeneral knowledge of functionality and operationof a transformer.
Prerequisites
Basic knowledge of electrical engineering.Fundamentals of DC circuits.Fundamentals of AC circuits.Basic knowledge of measurement for electricalvariables.
Main features1. General transformer overview Transformers and reactors in transmission and
distribution networks Transformer standards Transformer technology:
Electrical basic design, explained on a singlephase transformer, measuring andcalculation voltage ratio
Introduction to 3 phase transformers Mechanical design of power transformers
2. Transformer components Voltage regulation with tap changers External connections Introduction to cooling equipment
Overview control and protection devices3. Transformer in service Introduction to safety policies Transport and checking after delivery Overview of electrical measurements during
commissioning Maintenance:
Condition assessment and on- site diagnostics Oil regeneration and drying
9CA4130-0TE00-0DA4DE en 2
1,200 EUR
Distribution Transformers Grounding and Protection
Booking code:TR-DGRDPRO
Training objectives
The primary objective of this class is to improvethe participants understanding of the distributionsystem including primary and secondary systems,allowable connections, connections to be avoided,distribution system grounding types and over-current protection devices and applications.
US en 3
2,399 USD
30
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
31/92(Net prices)
General
SF6Gas Awareness
Booking code:SF6-AW
Training objectives
Participants will receive a basic level of SF6awareness as required for those personnel who
have some involvement with SF6filled equipment,or operate in areas where SF6in containers orSF6filled equipment is present. The personnel arenot directly involved in gas handling or operationof the equipment.
GB en 0.5
225 GBP
MX es 0.524,840 MXN
NL nl 0.5215 EUR
SF6Gas Competence
Booking code:SF6-COMP
Training objectives
Participants will receive the operational trainingwhich complies with EC 305/2008 and is accreditedby Energy & Utility Skills the UK sector skillscouncil. The training includes the full requirementsof those involved in the installation, operationand maintenance of SF6gas filled high voltage
switchgear.
GB en 2
920 GBP
NL nl 21,250 EUR
Substation ConditionMonitoring System Operation
Booking code:COND-NONIT
Training objectivesParticipants will be trained in operation andapplication of Siemens substation monitoringsystems.
GB en 1
520 GBP
UHF Partial DischargeMonitoring for GIS Substations
Booking code:GIS-UHF
Training objectives
The course will give a thorough understanding ofthe theory and application of Ultra High Frequency
monitoring of GIS equipment and the operation ofeither portable or continuous monitoring systems.
CO es 2
1,080,000 COP
GB en 2980 GBP
SF6European Certification Preparatory Course
Booking code:SF6-PREP
Training objectives
Train the participants, in compliance with theEuropean decrees in EC305/2008, to acquire the
authorization required to handle SF6gas duringSF6treatment operations. Theoretical and practicaltraining. If required, the trainee will be capable ofundergoing the theoretical and practical examina-tions to obtain European SF6certification.Training center is accredited by Ministry of theSustainable Development and Industry.
Target audience
The course is designed for quality specialists,environment engineers and those persons inter-vening on SF6loads in high voltage switchgear,on all levels of the operation and maintenancecycles of switching devices.
Prerequisites
No pre-requisites are required.
Main features
General SF6characteristics Presentation of the new regulations Chemical and physical properties Internal arc effect, personnel safety
Implementation of SF6in electrical equipment Role of the gas in MV and HV equipment Examples of applications
Environment: Impact on the environment(greenhouse effect, Kyoto protocol,EC agreements, etc.)
Regulations IEC regulations
Standards(IEC 60480, IEC 62271-303, IEC 60376)
Labeling, follow-up, storage, transport,regeneration
SF6tests (quality control) Hygrometry, tightness and pressure basics Measuring SF6decomposition
and purity products Pressure tests on compartments
Workshop
FR en 2Price on request
FR es 2Price on request
FR fr 2Price on request
EHV, HV and MVSubstations Overview:Arrangement, Protection,Control and CommunicationSystem
Booking code:SUB-SCHEME
Training objectives
To present the different types of High, Extra-Highand Medium voltage electrical substations,configuration schemes used in power generation,transmission and distribution, application andtechnical economic comparison.
CO es 3
1,560,000 COP
31
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
32/92(Net prices)
ro ec onProtection
Protection Technology Principles
Booking code:PR-PRIN
Training objectives
The participants will learn about basics of possibleapplications, principles of operation and the overall
concept of the most important protection devices.
Target audience
Employees of power supply utilities and the indus-trial sector who are familiar with the planning,commissioning and maintenance of power systemprotection equipment.
Prerequisites
Basic knowledge of electrical engineering.
Main features
Protection principles Earth fault Current transformer dimensioning Overcurrent-time protection
Distance protection Line and transformer dif ferential protection Busbar protection Frequency protection Motor protection
CO es 31,560,000 COP
9CA4140-0SE00-0DA2DE en 3
2,700 EUR
IN en 210,000 INR
MX es 368,580 MXN
NG en 3150,000 NGN
NL nl 31,350 EUR
RU ru 347,000 RUB
TR tr 32,300 TRY
Protective Relaying Fundamentals
Booking code:PR-FUNDA
Training objectives
This training provides participants with an under-standing of the protective devices and systems
commonly used in generation, transmission,subtransmission, and distribution systems.
Target audience
Recommended for engineers seeking an under-standing of protection fundamentals, the coursewould also be a valuable resource for engineersjust entering the system protection field.
Prerequisites
Fundamentals of power system engineering andthe basic mathematical skills, such as trigonometry,complex numbers, matrix algebra, and appliedcalculus.
Main features
Protection fundamentals and applications Protective relay operational characteristics Relay input sources (CTs and PTs) Generator protection Protection applications Transformer protection Bus protection Transmission line protection Over-current and distance relay Blinders on distance relay Out-of step relay Loss of excitation relay Relay coordination and over-current relays Fault current and breaker duty Instantaneous setting procedure
Distribution overcurrent protection Relays, fuses, reclosers, and sectionalizers Coordination of devices
PSEC 640US en 3
2,399 USD
System Protection Workshop on a Real TimeDigital Simulator RTDS
Booking code:RTDS-PS
Training objectives
The participants will learn about complex faultsituations with a transient network analyzer,
considering different network and protectionsystems.
Target audience
Experts for relay applications from utilities andindustry.
Prerequisites
Expert knowledge of protection technology.
Main features
Parameterization of 7SA Analysis of fault records and protocolls Theoretical explanation of network and
algorithms Automatic reclosure and syncronisation
Parameterization of 7SD Differential protection and communication Simulation of protection communication lines
and GPS Stabilisation of dif ferential protection Transformer differential protection Exchange of expert experience
9CA4140-0SE00-0DB5DE en 5
3,850 EUR
32
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
33/92(Net prices)
SIPROTEC 4 Application and Exercises
Booking code:SIP4-SYS
Training objectives
The participants will become familiar with theconcept and principle of operation of the digital
network protection systems SIPROTEC 4.
Target audience
Power system protection experts who have beenassigned to plan, commission and maintain digitalprotection systems.
Prerequisites
Basic knowledge of power system protection.Course Protection Technology Principles(PR-PRIN) or comparable knowledge.Course DIGSI 4 Basics (DIGSI4-B)or comparable knowledge.
Main features
General properties of SIPROTEC 4
Operation of protection relays with DIGSI 4 Devices in practical operation:
Overcurrent protection 7SJ Distance protection 7SA Transformer differential protection 7UT Differential protection 7SD Busbar protection 7SS SIPROTEC hardware Hardware, jumpers, interfaces, electrostatic
sensitive devices, firmware
9CA4140-0SE00-0DF1DE en 4.5
3,650 EUR
GB en 3
1,740 GBP
IN en 3
15,000 INR
NG en 4.5
250,000 NGN
NL en 2
Price on request
NO no 4
16,800 NOK
RU ru 4
57,000 RUB
SIPROTEC 4 Protection Devicesfor Service Engineers
Booking code:SIP4-SERV
Training objectives
The participants will have a deeper understandingof the nature of numerical protection devices.
They will understand the meaning of bountifulsettings and how to analyze malfunctions andknow remedies thereof.
Target audience
Engineers of power supply utilities and industrywho deal with the planning, configuration,commissioning, maintenance and operationof numeric protection systems.
Prerequisites
Basic knowledge of protection technology.
Main features
Principles and virtues of numerical protectiondevices
Hardware of numerical protection and settingsthereof
Operating and analysis software DIGSI 4.87 bythe scenario:
Planning department act 1 and 2 Commissioning department Maintenance department Multiple CFC exercises
Numerical protection: The duty tests Exercises accordingly and more with:
O / C protection 7SJ6 Distance protection 7SA52 or 7SA61 Transformer differential protection 7UT612
or 7UT613 Cable and line differential protection 7SD52
or 7SD610 Busbar differential protection 7SS52
or 7SS60 Quality assurance / repair forms
9CA4140-0SE00-0DF3DE en 5
3,700 EUR
GB en 5
2,900 GBP
NG en 5
250,000 NGN
SIPROTEC 4 Protection Devicesfor Expert Engineers
Booking code:SIP4-EXPER
Training objectives
The participants will have a deeper knowledgeof the state-of-the-art protection of power trans-
mission systems. They will know how to conceivecomplex protection schemes and be familiar withthe special requirements for the protection ofhigh and extra-high-voltage systems.
Target audience
Engineers of power supply utilities and industrywho deal with the planning, configuration andsettings of numeric protection systems.
Prerequisites
Basic knowledge of protection technology.
Main features
The task of protection systems What methods of protection are in use?
The nature of numerical protection CT requirements CT evaluating & dimensioning Data acquisition of transmission lines and cables Distance protection 7SA Transformer differential protection 7UT Line differential protection 7SD Motor protection Busbar differential protection 7SS
9CA4140-0SE00-0DF4DE en 5
2,800 EUR
33
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
34/92(Net prices)
Protection
SIPROTEC 4 ProtectionEngineering Complete:10 Days Certification Program
Booking code:SIP4-CERTI
Training objectives
The participants will be familiarized with selection,commissioning, operation and maintenance of
protection schemes and system protection equip-ments. They will get to know the sof twares usedto operate, to analyze faults and to the test thenumerical relays.
Target audience
Supervisors, engineers, field personal, techniciansand specialists involved in operation, planning,design, maintenance and servicing of switchgears,transformers and protecting equipments fromelectric utilities and the industrial sector.
Prerequisites
Basic knowledge of electrical engineering and firstrelevant exposure to power system protection.
Main features Principles of Numerical Protection Technology DIGSI 4 Basics of Protection And Control
Functions SIGRA 4 Efficient interpretation of fault
records of SIPROTEC-devices SIPROTEC 4 Protection Devices for Service
Engineers SIPROTEC 4 Secondary Relay Testing with the
OMICRON Test System
NG en 10525,000 NGN
SIPROTEC 4 Busbar Protection 7SS52
Booking code:SIP4-7SS
Training objectives
The participants become familiar with the princi-ples, the application, the operation, and functions
of the distributed busbar protection 7SS52.
Target audience
Employees from utilities or industry involved inthe planning, commissioning and maintenanceof busbar protection systems.
Prerequisites
Good knowledge of busbar protection technology.
Main features
Introduction to busbar protection 7SS52 Function overview Hardware and function splitting Communication and configuration Security measures
Protection algorithms Breaker failure protection Recommendations for settings Practical exercises with decentralized busbar
protection 7SS52 and CMC256 + CMA156of OMICRON
High impedance Low impedance A comparison
CO es 31,560,000 COP
9CA4140-0SE00-0DF2DE en 3
2,400 EUR
ES es 31,100 EUR
IN en 315,000 INR
Generator / Dynamics andProtection Workshop on a RealTime Digital Simulator RTDS
Booking code:RTDS-GEN
Training objectives
The participants will learn about complex faultsituations with a transient network analyzer,
considering different network and protectionsystems.
Target audience
Experts for relay applications from utilities andindustry.
Prerequisite
Expert knowledge of protection and generatortechnology.
Main features
Theory of generators in steady state andtransient conditions
Simulation of generators Generator stability and power swing
Generator protection device 7UM Setting calculation Analysis of fault records and protocols Exchange of expert experience
9CA4140-0SE00-0DB6DE en 5
3,850 EUR
34
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
35/92(Net prices)
SIPROTEC 4 Distance Protection 7SA
Booking code:SIP4-7SA
Training objectives
The participants will deepen their knowledgeof the use and functional test of the impedance
protection devices 7SA5 / 7SA6.
Target audience
Users from the field of power transmission anddistribution who deal with the testing, commis-sioning and maintenance of protection systems.
Prerequisites
Good knowledge of distance protection.
Main features
Basics of numerical impedance protection Fault detection and distance measurement Zone settings Signal comparison protection Demands on current- and voltage transformers
Distance protection on parallel lines Distance protection on tapped lines Teed feeder protection Parallel lines Power swing detection Application with serial compensation Operation and testing of a 7SA52 with
secondary test-kit CMC of OMICRON Fault analysis with SIGRA
CO es 21,080,000 COP
9CA4140-0SE00-0DA3DE en 3
2,400 EUR
ES es 31,100 EUR
GB en 3Price on request
IN en 315,000 INR
MX es 368,580 MXN
SIPROTEC 5 Busbar Protection 7SS85
Booking code:SIP5-7SS85
Training objectives
The participants become familiar with the princi-ples, the application, the operation and functions
of the centralized busbar protection 7SS85.
Target audience
Employees from utilities or industry involved inthe planning, commissioning and maintenanceof busbar protection systems.
Prerequisites
Basic knowledge of busbar protection technology.
Main features
Introduction to busbar production 7SS85 Function overview Hardware and function splitting Communication and configuration Security measures
Protection algorithms Recommendations for settings Practical exercises with centralized Busbar
protection 7SS85 and CMC256 + CMA156of OMICRON
9CA4140-0SE00-0DC2DE en 3
2,400 EUR
SIPROTEC 4 Machine / Motor Protection7UM & 7VE
Booking code:SIP4-7UMVE
Training objectives
The participants will learn about the principlesof operation and functions of generator block
protection and synchronization.
Target audience
Users from power supply utilities and industrialenterprises who deal with the testing, commis-sioning and maintenance of generator protectionsystems.
Prerequisites
Basic knowledge of generator protectiontechnology.Course DIGSI 4 Basics or comparableknowledge.
Main features
Generator block protection application example
Explanation of protection functions andparameters
Generator capability curve Synchronization WEB Monitor RTD box Presentation of the generator model Selection of protection functions Configuration and operation
of SIPROTEC 4 7UM Configuration and operation of SIPROTEC 4 7UT Configuration and operation of SIPROTEC 4 7VE Test of protection functions and synchronization
with secondary test equipment Connection of protection devices to the
generator model Operation of the synchronous generator Measurements and operational indications Tripping on faults by generating faults Analysis of fault records and fault indications
9CA4140-0SE00-0DJ1DE en 4
3,100 EUR
IN en 315,000 INR
35
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
36/92(Net prices)
SIPROTEC 5 Distance & Line DifferentialProtection 7SL
Booking code:SIP5-7SL
Training objectives
The participants will deepen their knowledgeof the use and functional test of the distance and
line differential protection devices SIPROTEC 5 7SL.
Target audience
Users from the field of power transmission anddistribution who deal with the testing, commis-sioning and maintenance of protection systems.
Prerequisites
Good knowledge of distance and line differentialprotection.
Main features
Properties of SIPROTEC 5 7SL devices Requirements on current and voltage
transformers Basics of numerical impedance protection
Fault detection and distance measurement Zone settings Signal comparison protection Distance protection on parallel lines Distance protection on tapped lines Power swing detection Automatic reclosing Basics of numerical line differential protection Multiple topologies Protection of transformer and line as a unit Differential protection communication:
Basics, interfaces, network technology,GPS synchronization
Setting of device with DIGSI 5 Operation and testing of a SIPROTEC 5 7SL
relays with secondary test-kit CMC of OMICRON Double sided fault locator Commissioning and maintenance Fault analysis with SIGRA
9CA4140-0SE00-0DK7DE en 3
2,400 EUR
Protection
SIPROTEC 4 Application and Exercisesof Generator / Motor Protection
Booking code:SIP4-GEN
Training objectives
The participants will gain knowledge of the modeof operation, applications and configuration of
numerical unit and auxiliary protection systems.
Target audience
Employees from utilities and that sector of industryconcerned with planning, maintenance and testingof machine protection equipment.
Prerequisites
Basic knowledge of protection and generatortechnology.Course DIGSI 4 Basics (DIGSI4-B)or comparable knowledge.
Main features
Introduction to the principles of machineprotection
SIPROTEC 4 machine protection Short-circuit protection Differential protection Recommendations on CT coordination Rotor earth fault protection Underexcitation protection Principles of stator earth fault protection Engineering of stator earth fault protection Configuration examples Practical exercises 7UM as motor protection Paralleling device 7VE
CO es 31,560,000 COP
9CA4140-0SE00-0DF5DE en 3.5
3,350 EUR
SIPROTEC 4 Line Differential Protection 7SD
Booking code:SIP4-7SD
Training objectives
The participants will deepen their knowledge ofthe use and functional test of the line differential
protection devices 7SD.
Target audience
Users from the field of power transmission anddistribution who deal with the testing, commis-sioning and maintenance of protection systems.
Prerequisites
Good knowledge of line dif ferential protection.
Main features
Basics of numerical line differential protection Information on protection functions Demand on current transformer Multiple topologies Protection of transformer and line as a unit
Numerical differential protectioncommunication:
Basics, interfaces, network technology, GPS synchronization
Application of the WEB Monitor Operation and testing of a 7SD610 resp.
7SD523 topology with secondary test-kit CMCof OMICRON at hand of multiple tasks
CO es 31,560,000 COP
9CA4140-0SE00-0DA4DE en 3
2,400 EUR
ES es 31,100 EUR
GB en 2Price on request
IN en 315,000 INR
MX es 368,580 MXN
36
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
37/92(Net prices)
SIPROTEC 4 Overcurrent andMotor Protection 7SJ
Booking code:SIP4-7SJ
Training objectives
The participants will deepen their knowledge ofthe use and functional test of the definite-time /
inverse-time overcurrent protection devices 7SJ.
Target audience
Users from the field of power transmission anddistribution who deal with the testing, commis-sioning and maintenance of protection systems.
Prerequisites
Good knowledge of overcurrent protection.
Main features
Fault types and measuring value achievement Definite-time / inverse-time characteristics Pick up security and - dependability Fault clearance- and grading times The three stages of application of DMT / IDMT
protection with their according application Motor protection within the overcurrent
protection Thermal overload protection Motor startup monitoring Motor restart inhibit
Multiple functional checks with 7SJ61
9CA4140-0SE00-0DG2DE en 3
2,400 EUR
ES es 31,100 EUR
GB en 3
Price on request
IN en 315,000 INR
SIPROTEC 5 Overcurrent andMotor Protection 7SJ & 7SK
Booking code:SIP5-7SJSK
Training objectives
The participants will deepen their knowledgeof the use and functional test of the SIPROTEC 5
7SJ85 and 7SK85 devices.
Target audience
Users from the field of power transmission anddistribution who deal with the testing, commis-sioning and maintenance of protection systems.
Prerequisites
Basic knowledge of protection technology.Course DIGSI 5 Basics or comparableknowledge.
Main features
Fault types and measuring value achievement Properties of SIPROTEC 5 7SJ and 7SK devices Definite-time / inverse-time characteristics
Pick up security and dependability Fault clearance and grading times The three stages of application of DMT / IDMT
protection with their according application Motor protection
Thermal overload protection Motor startup monitoring Motor restart inhibit
Setting of device with DIGSI 5 Multiple functional checks with 7SK85 and
secondary test set CMC of OMICRON
9CA4140-0SE00-0DC1DE en 3
2,400 EUR
SIPROTEC 4 Transformer DifferentialProtection 7UT
Booking code:SIP4-7UT
Training objectives
The participants will deepen their knowledgeof the use and functional test of the transformer
differential protection devices 7UT6.
Target audience
Users from the field of power transmission anddistribution who deal with the testing, commis-sioning and maintenance of protection systems.
Prerequisites
Good knowledge of transformer dif ferentialprotection.
Main features
Basics of numerical transformer differentialprotection
Adaption of ratio, vector group and impactof tap-changer
Transformer tap adjustment Stability during inrush and overexcitation Demand on current transformers Application examples (busbar protection,
auto transformer, multi-winding transformer) Earth-differential protection (REF) for faults
near starpoint Setting of device with DIGSI Operation and testing of a 7UT61 with
secondary test-kit CMC of OMICRON Application of the WEB Monitor function Fault analysis with SIGRA
9CA4140-0SE00-0DG3DE en 3
2,400 EUR
ES es 31,100 EUR
37
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
38/92(Net prices)
Protection
SIPROTEC 5 Transformer DifferentialProtection 7UT
Booking code:SIP5-7UT
Training objectives
The participants will deepen their knowledgeof the use and functional test of the transformer
differential protection devices SIPROTEC 5 7UT.
Target audience
Users from the field of power transmission anddistribution who deal with the testing, commis-sioning and maintenance of protection systems.
Prerequisites
Good knowledge of transformer differentialprotection.
Main features
Properties of SIPROTEC 5 7UT devices Basics of numerical transformer differential
protection Adaption of ratio, vector group and impact
of tap-changer Stability during inrush and overexcitation Demand on current transformers Application examples (busbar protection,
auto transformer, multi-winding transformer) Earth-differential protection (REF) Setting of device with DIGSI 5 Operation and testing of a SIPROTEC 5 7UT
with secondary test-kit CMC of OMICRON Commissioning and maintenance Fault analysis with SIGRA
9CA4140-0SE00-0DK6DE en 3
2,400 EUR
SIPROTEC 4 Secondary Testing withOMICRON Test System CMC
Booking code:SIP4-CMC
Training objectives
The participants will gain practical knowledge ofessential device parameters and their secondary
testing. The course focuses on hands-on creationof test documents for distance, cable and trans-former differential protection in medium and highvoltage grids.
Target audience
Engineers and technicians of power utilitiesand industries who deal with commissioningand periodic testing of protective devices.
Prerequisites
Basic knowledge of protection technology.
Main features
Introduction to the OMICRON test system Creating test documents (OCC-files) for
overcurrent, distance and differentialprotection:
Testing the starting functions Testing tripping characteristic Testing harmonic stabilisation
(inrush and overexcitation) Testing switch-onto-fault (SOTF) Testing the automatic reclosure function Earth fault detection in non-earthed systems Practical application of the created test
documents on SIPROTEC devices
CO es 31,560,000 COP
9CA4140-0SE00-0DF6 DE en 32,400 EUR
GB en 32,100 GBP
NG en 3150,000 NGN
Fault Record Analysis
Booking code:SIP4-FANA
Training objectives
The participants will be able to analyze fault
records presented in the Comtrade format and tounderstand the protections behavior. The courseincludes the views and diagrams of SIGRA and theways of fault record analysis. The par ticipants willalso analyze fault records and extensively discussthe results. The analysis emphasizes timings,variations of current and voltages, determinationof impedances, fault location and the analysis forharmonics.
BR pt 2Price on request
SIPROTEC Compact(7SJ80, 7SK80, 7RW80, 7SD80)
Booking code:SIP-COMPA
Training objectives
The participants will learn about hardware, settingvalues and using of the SIPROTEC 4 compact
devices. Additionally, basic functions of DIGSI 4.8software will also be trained.
9CA4140-0SE00-0DD5DE en 2
1,300 EUR
System ProtectionCommunication ofPower Transmissionand Distribution Networks
Booking code:PR-COM
Training objectives
The participants will become familiar with thebasics of communication technology. There willbe an overview of the various ways in whichcommunication components and protocols canbe used and are able to specify requirementsfor modern communications systems.
9CA4140-0SE00-0DA7 DE en 21,250 EUR
38
-
7/25/2019 SiemensPowerAcademyTD Katalog en 2014
39/92(Net prices)
SIPROTEC 4 Protection & Control SystemEngineering
Booking code:SIP4-ENGIN
Trai