short wave diathermy (continuous 500watt & pulse 1000...
TRANSCRIPT
Wave therapy
Short wave diathermy (continuous 500watt & pulse 1000)
watt with disk electrode Model no- pcd-101
Applications
* Cooling fan to cool the chassis and the valve, ensuring prolonged tube life.
* Filament voltage can be adjusted in six steps.
* The output power is adjustable in five steps.
* It has max 99 min digital treatment timer
* Max. output power in cont. mode 500 W
* Max. output power in pulse mode 400 W
* Pulse Frequency 2, 20 & 100 Hz.
Technical specification
* Model - Dyno Pulse
* Input Supply - 220V Ac/50 hz
* Power Output - 500W RF
* Operating Frequency - 27.12 MHz
* Wave Length - 11.06 meter
* RF Power Source - Triode Valve
* Power Fuse - 7 Amp
* Weight - 60 kg. approx.
Accessories
•••• One pair condenser paid
•••• Two pair output cable
•••• One power cable
•••• One dust cover
•••• One operating manual
•••• One pair disk-electrode
•••• Five power fuse
Short wave diathermy 500watt Model no –pcd-102
Applications
* Cooling fan to cool the chassis and the valve, ensuring prolonged tube life.
* Filament voltage can be adjusted in six steps.
* The output power is adjustable in five steps.
* It has max 30 min treatment timer
* Max. output power in cont. mode 500 W
Technical specification
* Model - Dyno Pulse
* Input Supply - 220V Ac/50 hz
* Power Output - 500W RF
* Operating Frequency - 27.12 MHz
* Wave Length - 11.06 meter
* RF Power Source - Triode Valve
* Power Fuse - 7 Amp
* Weight - 60 kg. approx.
Short wave diathermy (Table Top) Model no- pcd-103
Applications
* Cooling fan to cool the chassis and the valve,
ensuring prolonged tube life..
* The output power is adjustable in five steps.
* It has max 30 min treatment timer
* Max. output power in cont. mode 500 W
Technical specification
* Model - Dyno Pulse
* Input Supply - 220V Ac/50 hz
* Power Output - 500W RF
* Operating Frequency - 27.12 MHz
* Wave Length - 11.06 meter
* RF Power Source - Triode Valve
* Power Fuse - 7 Amp
* Weight - 60 kg. approx.
Short Wave Diathermy Continuous
250Watts Portable Model no- pcd-104
Applications
* Cooling fan to cool the chassis and the valve, ensuring prolonged tube life.
* The output power is adjustable in five steps.
* It has max 30 min manual treatment timer
* Max. output power in cont. mode 250 W
Technical specification
* Model - Portable model
* Input Supply - 220V Ac/50 Hz
* Power Output - 250W RF
* Operating Frequency - 27.12 MHz
* Wave Length - 11.06 meter
* RF Power Source - Pentode Valve
* Power Fuse - 5 Amp
* Weight - 18 kg. approx.
Accessories
•••• One pair condenser paid
•••• One pair output cable
Long wave diathermy ultra Model no- pcd-105
long wave Diathermy
Clinical results prove that Long wave is much better modality than Shortwave and Ultrasound
• Long wave Diathermy treatment is based on Capacitor Field
• It uses 1Mhz Alternating Current Frequency.
• Long wave improves circulation, reduces pain and improves Mobility
• Long wave gives penetration up to 4 cm
• Raised temperature duration is for 45 minutes
• Unlike SWD, Long wave will not produce any interference with other equipments.
• Unlike Ultrasound, Long wave will not have any irritation to boney parts
• Most of the energy remains in high density tissue like ligaments & tendons
• Consumes very less electricity compared to Shortwave Diathermy
• Solid State Design No valves or Crystals are used.
• Portable only 7.5kgs
Use of Long wave treatment areas:
• Tendinitis
• Ligament injuries
• Jumper's knee
• Lower back pain
• Detuning of muscles
• Myalgia
• Distortion of ankle with edema
• Tendinitis/paraendinitis
• Arthritis
• M. piriformis syndrome
• Bursitis
• Torricelli’s
• WAD — Whiplash Associated Disorders •Impingement
• Rotator cuff symptoms
• Frozen shoulder syndrome
• Finger ligament distortions Say goodbye to your Shortwave Diathermy and Ultrasound
Therapy.
• totech.
Standard Accessories:
• Applicator 4No.
• Lotion bottle 1No.
• Operating Manual 1No.
• Ground rod
• Out put probe
Technical specification
• Wave lenth : 300 meter
• Frequency : 1 mhz
• Display : back light display
• Timer : 1 to 5 minuts
• Power : variable in 16 digital steps
• Mains : 230 v ,50 Hz
•
Micro wave diathermy standard Model no- pcd-106
.
Microwave Diathermy Available Models: 2500 CP: Continuous and pulsed 2500 C: Continuous • Power upto (250W-1600 W). • LCD TFT 6 inch graphic display. •64KB smartcard for making patient defined programmes (upto 50). • Built-in 50 treatment protocols. •Pulse function allows prolonged session without discomfort. •Types of antenna available : Circular, • Rectangular (Optional), Three Dimensional (Optional)
Digital ultrasonic (1 Mhz ) Dyno Model no- pcd-107
Applications
* This unit is fully micro processor based, light weighted, compact, easily carrible
* Silent Features of this Unit:-
* Solid state digital high frequency generation.
* Ergonomic applicator
* Operating System analogue
* Reset & start
Technical specification
* Input Voltage - 220v Ac/500 Hz
* Frequency - 1 MHz.
* Output Mode - Continuous / Pulse
* Pulse Ratio - 1:1, 1:4, 1:7, 1:9
* Power Output - 3.0w/cm2 maximum
* Treatment timer - 0-20 timer
* Weight - 2.5 Kgs approx
* Power Fuse - 1amp
Standard Accessories
•••• One applicator 1Mhz.
•••• Five fuse
•••• One jell bottle
•••• One Power cable
Digital ultrasonic (1 & 3Mhz ) Dyno Model no- pcd-108
Digital ultrasonic (1 Mhz) compact Model no- pcd-109
Applications
* This unit is fully micro processor based, light weighted, compact, easily carrible
* Silent Features of this Unit:-
* Solid state digital high frequency generation.
* Ergonomic applicator
* Operating System analogue
Technical specification
* Input Voltage - 220v Ac/500 Hz
* Frequency - 1 MHz.
* Output Mode - Continuous / Pulse
* Pulse Ratio - 1:1, 1:4, 1:7, 1:9
* Power Output - 3.0w/cm2 maximum
* Treatment timer - 0-20 timer
* Weight - 2.5 Kgs approx
* Power Fuse - 1amp
* Dimension (L.B.H.) - 8”x9”x3”
Standard Accessories
•••• One applicator 1Mhz.
•••• Five fuse
•••• One jell bottle
•••• One Power cable
Digital ultrasonic (1 Mhz) physioModel no- pcd-110
Applications
* This unit is fully micro processor based, light weighted, compact, easily carrible
* Silent Features of this Unit:-
* Solid state digital high frequency generation.
* Ergonomic applicator
* Operating System analogue
Technical specification
* Input Voltage - 220v Ac/500 Hz
* Frequency - 1 MHz.
* Output Mode - Continuous / Pulse
* Pulse Ratio - 1:1, 1:4, 1:7, 1:9
* Power Output - 3.0w/cm2 maximum
* Treatment timer - 0-20 timer
* Weight - 2.5 Kgs approx
* Power Fuse - 1 amp
Standard Accessories
•••• One applicator 1 Mhz.
•••• Five fuse
•••• One jell bottle
•••• One Power cable
Advance ultrasonic (1 MHz) Lcd Model no- pcd-111
Ultrasound Frequency: 1 MHz OR 1, 3 MHz Ultrasonic Output: Maximum 15 Acoustic Out Put Mode: Continuous and Pulsed Pulse Ratio: Fix:10, 20, 50, 100Hz Treatment Time: Auto Fix Timer: Electronic Timer with digital display with auto alarm. Pulse Setting : Digital Power Input: 90 VA 200V 50Hz A.C