SHIP SECURITY ALERT SYSTEM (SSAS) IC-307 OPERATOR'S MANUAL www.furuno.co.jp MODEL

Upload: vuongnhu

Post on 21-Mar-2018

213 views

Category:

Documents


1 download

TRANSCRIPT

SHIP SECURITYALERT SYSTEM (SSAS)

IC-307

OPERATOR'S MANUAL

www.furuno.co.jp

MODEL

The paper used in this manualis elemental chlorine free.

・FURUNO Authorized Distributor/Dealer

9-52 Ashihara-cho,Nishinomiya, 662-8580, JAPAN

Telephone : +81-(0)798-65-2111

Fax : +81-(0)798-65-4200

A : MAY 2004Printed in JapanAll rights reserved.

D1 : JUN . 06, 2008Pub. No. OME-56351-D1

*00015035913**00015035913*(DAMI ) IC-307(SSAS)*00015035913**00015035913** 0 0 0 1 5 0 3 5 9 1 3 *

1

TABLE OF CONTENTS

SYSTEM CONFIGURATION .........................................................................................2

1. OVERVIEW OF SSAS ..............................................................................................4

2. INSTALLATION.........................................................................................................6 2.1 Mounting ......................................................................................................................... 6

2.1.1 Junction box (for FELCOM 16) ............................................................................... 6 2.1.2 I/F box IC-312 (for FELCOM 12)............................................................................. 7 2.1.3 SSAS alert unit ....................................................................................................... 8

2.2 Wiring............................................................................................................................ 10 2.2.1 Junction box (for FELCOM 16) ............................................................................. 10 2.2.2 I/F box IC-312 (for FELCOM 12)........................................................................... 11 2.2.3 SSAS alert unit ..................................................................................................... 12

2.3 Initial Settings................................................................................................................ 13

3. OPERATION............................................................................................................14 3.1 Operation Mode ............................................................................................................ 14

3.1.1 Changing the password ........................................................................................ 14 3.1.2 SSAS manager mode........................................................................................... 15

3.2 Setting SSAS Report Destination and Message Contents............................................. 16 3.3 Transmitting SSAS Report ............................................................................................ 19 3.4 Testing the Button .........................................................................................................21 3.5 SSAS Report Test ......................................................................................................... 27

OUTLINE DRAWINGS...............................................................................................D-1 INTERCONNECTION DIAGRAMS ...........................................................................S-1

2

SYSTEM CONFIGURATION Regulations require at least two SSAS alert units.

FELCOM 15

PrinterPP-510

ANTENNAUNIT

IC-115

TERMINAL UNITIC-215

JUNCTIONBOX

IC-315

Navigator

100-115/200-230 VAC1φ, 50/60 Hz

: Standard Supply: Option: Local Supply

AC-DC Power SupplyPR-240-CE*1

*1 Any AC-DC power supply fulfilling requirements of IEC 60945 may be used.

PersonalComputer

(PC/AT compatible)

EGC PrinterPP-50

Shipboard LAN (Ethernet)GPS receiver

OP16-24

Mini Keyboard

DGPS

Distress Alert/Received Call Unit

IC-305

Alarm UnitIC-306

24 VDC

Printer

SSAS Alert UnitIC-307

SSAS Alert UnitIC-307

(Max. 3 units)

SSAS Alert UnitIC-307

12-24 VDC

24 VDC

24 VDC

FELCOM 16

: Standard: Option: Local Supply

PRINTER

ANTENNAUNIT

IC-116

COMMUNICATION UNIT IC-216(with internal GPS receiver)

AC-DCPower SupplyPR-240-CE

PERSONALCOMPUTER

(PC/AT compatible)POWER IO

INMARSAT MINI-C MOBILE EARTH STATIONFURUNO

POWER

LOGIN

TX ERROR

JUNCTION BOXIC-315

100-115/200-230 VAC1φ, 50/60 Hz

12-24 VDC

24 VDC

SSAS Alert UnitIC-307

SSAS Alert UnitIC-307

(Max. 3 units)

SSAS Alert UnitIC-307

3

FELCOM 12

Navigator

: Standard

: Option

: User Supply

INMARSAT-C MOBILE EARTH STATION

POWERON OFF

POWER BRIGHT CONTRAST

Antenna UnitIC-112

Terminal UnitIB-581/IB-582

24 VDC

CommunicationUnit

IC-212

Mini Keyboard

24 VDC

PriinterPP-510

24 VDC

100/110/200/220V1φ, 50/60 Hz

AC-DC Power Supply

PR-300

Distress Alert UnitIC-302

Received Call UnitIC-303

Distress Alert UnitIC-302

OR

Distress Message ControllerDMC-5

24 VDC

PC (PC/AT compatible)

OR

Terminal UnitIB-581/IB-582

SSAS Alert UnitIC-307

SSAS Alert UnitInterfaceIC-312

24 VDC

SSAS Alert UnitIC-307 (Max. 3 units)

SSAS Alert UnitIC-307

4

1. OVERVIEW OF SSAS The IC-307 SSAS (Ship Security Alert System) Alert Unit connects to the Inmarsat-C MES FELCOM 15/FELCOM 12 or the Inmarsat Mini-C FELCOM 16 for the purpose of alerting specified addresses (for example, your ship’s company) that your ship is under attack by intruders. The SOLAS Resolution XI-2/6 requires vessels of 500 GT or more constructed before 01 July 2004 to install an SSAS. When your ship is under attack an SSAS report, which contains your ship’s name, MMSI No., position, etc. is sent to up to five locations, specified by the ship’s captain or authorized personnel. No audible or visible alarm is generated while the SSAS report is being transmitted, to prevent discovery of the report by the intruders. The SSAS is protected with a password to prevent unauthorized setting or testing of it by other than the ship’s captain or authorized personnel.

Headquarters

Ship

Ship's Company,Management Company

Inmarsat System

Ship Name, MMSI No.,Ship Position, etc.

5

SSAS operation flow

1. Open the cover of the button and then press the button.

(This is a latch-type button; hit and release to activate the button.)

2. If addresses have been preset, the SSAS report is sent to one address 30 seconds after the button is activated. (Max. 5 addresses)

(You may cancel transmission of the SSAS report by pressing the button again within 30 seconds of the initial press.)

3. An LES sends acknowledgement to your ship.

4. Steps 2-3 and are repeated in case of multiple addressees.

5. Continuous transmission of the SSAS report begins. (The interval at which to transmit the SSAS report to each address can be specified. The SSAS report is continuously transmitted while the button is ON, at the interval selected.)

6. To stop transmission, press the button again to deactivate it. (This is only possible in the SSAS manager mode. See paragraph 3.1.)

6

2. INSTALLATION

2.1 Mounting 2.1.1 Junction box (for FELCOM 16) The junction box IC-315 is required when installing the SSAS on the FELCOM 16; it is already installed on the FELCOM 15. Separate the junction box from a magnetic compass by the distances shown below to prevent deviation to a magnetic compass. Standard compass: 1.0 m Steering compass: 0.7 m 1. Remove four screws from the unit to separate the cover from the unit. 2. Fix the unit to the mounting location with four self-tapping screws (4x16, supplied). 3. Connect the cables appropriately referring to paragraph 2.2.1.

120 ±0.5

70 ±0.5

Junction box IC-315 The junction box is connected to the communication unit with a 2 meter cable, with D-sub connector (at the communication unit). Therefore, locate the junction box within two meters of the communication unit.

7

2.1.2 I/F box IC-312 (for FELCOM 12) The I/F box is required to connect the SSAS alert unit to the FELCOM 12. The I/F box is connected to the communication unit with a 5 m cable (17JE-573-10 harness). Accordingly, locate the interface within 5 m of the communication unit. Keep the following compass safe distances in mind when choosing the mounting location: Standard compass: 0.65 m Steering compass: 0.45 m 1. Unfasten four screws to remove the cover. 2. Use four self-tapping screws (3X10, supplied) to fix the unit to the mounting location. 3. If the cable is led in from the rear of the unit, change the clamp location as follows:

a) Unfasten two screws to remove the clamp. b) Turn the clamp 90 degrees. c) Fasten the clamp.

Unfasten two screws.

Turn

Fasten clamp with two screws.

Clamp

4. Pass the cable through the clamp and connect it to the terminal board, referring to the interconnection diagram.

8

2.1.3 SSAS alert unit Separate the junction box from the SSAS alert unit by the distances shown below to prevent deviation to a magnetic compass. Standard compass: 0.70 m Steering compass: 0.45 m Locate the SSAS alert unit where it cannot be found by intruders. The location should be known only by ship’s captain and authorized personnel. Bulkhead mounting

1. Remove four screws from the unit to separate the bottom chassis from the top cover. 2. Fix the unit to the mounting location with four self-tapping screws (supplied). 3. The cable can be lead in from the bottom or the rear panel. For rear panel entrance,

change the clamp orientation as follows: a) Unfasten three screws to remove the cable clamp. b) Turn the clamp 90 degrees. c) Refasten the clamp with three screws unfastened at step a) to fix the clamp.

Unfasten three screws.

Turn

Fasten three screws.

Clamp

4. Run the cable thru one of the cable entrances and connect it to terminal board.

9

5. Attach the switch cover as shown below. Note that the cover may be turned 180° to change cover opening direction.

Switch cover

Press here and hold down for five seconds.

Flush mounting

The optional flush mount kit OP16-28 (Code No. 004-448-010) is required.

Name Type Code No. Qty Remarks Fixture 16-018-7201-1 100-317-931 1 Pan head screw M3x6 000-800-362 4 Self-tapping screw 4x16 000-802-080 4

1. Cut out the mounting position referring to the outline drawings at the back of this manual.

2. Fix the unit to the fixture with four pan head screws (supplied). 3. Fasten the fixture with the unit to the mounting location with four self-tapping screws

(supplied). 4. Attach switch cover as shown above.

10

2.2 Wiring 2.2.1 Junction box (for FELCOM 16) Use the junction box IC-315 to connect the SSAS alert unit to the FELCOM 16. Unfasten four screws to remove the cover to connect cables to terminal board. For detailed wiring information see the interconnection diagram. For connection, use the JIS cable TTYCS-4 (or equivalent, see next page for sectional view of this cable) or the CO-SPEVV-SB-C 0.2x5P. When using the CO-SPEVV-SB-C 0.2x5P cable, replace the cable clamp with the cable clamp 16-018-6008-1, supplied with the junction box.

Cover

Terminalboard

CommunicationUnit

Procedure

1. Insert driver from direction 1 .

2. Tilt slightly toward 2 .

3. Insert cable core to 3 .

Core 7 mm

12

3

Vcc

GND

TD/RD-A

TD/RD-B

NC

TD-A(NAV)

TD-B(NAV)

RD-A(NAV)

RD-B(NAV)

GND

DMC OUT-H

DMC OUT-C

DMC IN-H

DMC IN-C

DMC CTR

IC-3

05/3

06123456789101112131415

Cable clamp(top)

Note 1: Do not insert the cable too deeply, to prevent pinching the sheath.

Note 2: Pull each cable slightly to con-firm that they are in their holes securely.

90mm15mm 7mm

16S0344

Fold back braided shield ontosheath and fix by cable clamp.

Cable clamp Cable clamp(bottom)

Junction box IC-315

11

2.2.2 I/F box IC-312 (for FELCOM 12) FELCOM 12 is connected to the SSAS Alert Unit via the I/F Box IC-312. For detailed wiring refer to the interconnection diagram at the back of this manual.

15 mm 40 mmCut and tapeunused wiresto prevent short.

CO-SPEVV-SB-C 0.2X5P or TTYCS-4

Twist shield.

Clamp for cableTTYCS-4 (or equivalent)

Clamp for cableCO-SPEVV-SB-C 0.2X5P

Conductor

S = 0.75 mmφ = 1.11 mm

2

Armor

Shield

Sheath

Sectional view of cable TTYCS-4

16P0231

1 2 3 4 5 6

Cable from SSAS Alert Unit

Communication Unit(rear view)

17JE-573-10 Harness (5 m)

24 VDC

MJ-A3SPF0016-035 (3.5 m)

BUZZER DMC2DMC1 ANT BREAKER 24VDC

DTE 1 DTE 2 DATA

NMEA

OR

Wiring I/F box IC-312

12

2.2.3 SSAS alert unit Three SSAS alert units can be connected. For wiring, see the illustrations below and the interconnection diagram at the back of this manual. For the terminal unit (FELCOM 15) and the communication unit (FELCOM 16/FELCOM 12), the wiring of the SSAS is monitored and if in error “TROUBLE: SSAS UNIT connection abnormality.” is displayed. Further the ERROR lamp (FELCOM 16) flashes.

JunctionBox

IC-307(No.1)

IC-307(No. 2)

IC-307(No. 3)

Connect wiring to the terminal board 16P0229 inside the SSAS unit. To differentiate between units in case of multiple unit installation, change jumper block settings as shown below, in accordance with how many units are installed.

IC-307

Clamp for cableCO-SPEVV-SB-C0.2x5P

15 mm 40 mm 10 mm

CO-SPEVV-SB-C 0.2X5Por TTYCS-4

Cut and tapeunused wiresto prevent short.

Twist shield.

IC-307

Two IC-307: No. 2Three IC-307: No. 3

Two IC-307: No. 1Three IC-307: No. 1 and No. 2

Clamp for cable TTYCS-4or equivalent

Jumper settings for two IC-307

JP1

JP2

No.1 unit* No. 2 unit No. 3 unit

YesJumper Unit

YesNo

No

Jumper settings for three IC-307

YesNo

JP1

JP2

No.1 unit*Jumper Unit

YesNo

No. 2 unit*

YesNo

No. 1 unit: Unit with two cables connnected to it.No. 2 unit: Unit with one cable connnected to it.

No. 1 and No. 2 units: Units with two cables connnected to them.No. 3 unit: Unit with one cable connnected to it.

*: Default setting

16P0229

1 2 3 4 5 6

16P0229

1 2 3 4 5 6

JP2JP1JP2JP1

ConductorS = 0.75 mmφ = 1.11 mm

2

Sectional view of cable TTYCS-4

Armor

Shield

Sheath

f = 16.3 mm

Cable Fabrication

Wiring inside the SSAS alert unit

13

2.3 Initial Settings Set up the SSAS as follows: 1. FELCOM 15/FELCOM 12: Press [F8], [F2] to show the System Setup menu.

FELCOM 16: Press [F8], [F1] to show the System Setup menu. 2. Press [↓] to choose Command Window and then press the [Enter] key.

Command Window

RFCONCPU ***[ Main Menu ]1. Remote Box Setup2. Internal GPS SetupEnter JOB No. :

Command Window

RFCONCPU ***[ Main Menu ]1. Remote Box SetupEnter JOB No. :

FELCOM 15/FELCOM 16 FELCOM 12 3. Type “furunoservice” (without quotation marks) in the Enter JOB No. field and then press

the [Enter] key. The prompt PASSWORD appears. 4. Enter password (see FURUNO Information for SSAS) then press the [Enter] key. Then,

the item Main Menu is displayed in reverse video. 5. Press [1], [Enter], [1], [Enter]. One of the following windows appears.

FELCOM 16FELCOM 15

[ SSAS I/F (IC-312) ]1. DTE2 Port2. DATA Port3. OFF E: ExitEnter No.:

FELCOM 12

[ DMC ]1. SSAS(IC-307)2. DMC3. OFF4: SSAS(Momentary SW) E: ExitEnter No.:

[ SSAS ]1. ON(IC-307)2. OFF3: Momentary SW (for USCG)E: ExitEnter No.:

6. FELCOM 15/FELCOM 16: Press [1], [Enter]. This enables the SSAS functions.

FELCOM 12: Choose the port where the SSAS unit is connected and then press the [Enter] key.

7. Press the [Esc] key several times to close the menu. Note: Test the SSAS button and SSAS report for proper operation, referring to paragraphs

3.4 and 3.5, respectively.

14

3. OPERATION

3.1 Operation Mode There are two menu operating modes: Normal mode: Menus other than SSAS-related menus are displayed. SSAS manager mode: The mode is activated by the password entered by the ship’s

captain or authorized personnel. The indication “SSAS Manager Mode” is shown at the top of the screen when this mode is activated, and it is flashing on the FELCOM 15/FELCOM 16. All SSAS-related menus are available. Transmission of the SSAS report may be cancelled in this mode. The equipment starts up in the normal mode, regardless of the mode in use when the power is turned off.

3.1.1 Changing the password The default password is “ship security alert”. Ship’s captain or authorized personnel may change the password as follows: 1. FELCOM 15/FELCOM 12: Press [F8], [F2] to show the System Setup menu.

FELCOM 16: Press [F8], [F1] to show the System Setup menu. 2. Press [↓] to choose Command Window and then press the [Enter] key.

Command Window

RFCONCPU ***[ Main Menu ]1. Remote Box Setup2. Internal GPS SetupEnter JOB No. :

Command Window

RFCONCPU ***[ Main Menu ]1. Remote Box SetupEnter JOB No. :

FELCOM 15/FELCOM 16 FELCOM 12 3. On the Enter JOB No. field, type “ssas password” (without quotation marks) and then

press the [Enter] key. The prompt OLD PASSWORD appears. 4. Type your current password and then press the [Enter] key. The prompt NEW

PASSWORD appears. 5. Enter new password, using at least six characters, and then press the [Enter] key. The

prompt RETYPE NEW PASSWORD appears. Note: If less than six characters are entered for the password, the message “Please

use a longer password.” appears. Enter a longer password. 6. Enter new password again and then press the [Enter] key. The message “Password

changed” appears. 7. Press the [Esc] key several times to close the menu. Note: The SSAS manager mode cannot be unlocked without the proper password.

15

3.1.2 SSAS manager mode All SSAS-related settings are set in the SSAS manager mode. Do the following to access this mode. 1. FELCOM 15/FELCOM 12: Press [F8], [F2] to show the System Setup menu.

FELCOM 16: Press [F8], [F1] to show the System Setup menu. 2. Press [↓] to choose Command Window and then press the [Enter] key.

Command Window

RFCONCPU ***[ Main Menu ]1. Remote Box Setup2. Internal GPS SetupEnter JOB No. :

Command Window

RFCONCPU ***[ Main Menu ]1. Remote Box SetupEnter JOB No. :

FELCOM 15/FELCOM 16 FELCOM 12 3. On the Enter JOB No. field, type “ssas manager” (without the quotation marks) and then

press the [Enter] key. Note: If there is no SSAS equipment connected, the message "Command Ignored: No SSAS button is installed." appears.

4. Type password and then press the [Enter] key to go into the “SSAS Manager Mode”. The indication “SSAS Manager Mode” is shown at the top of the screen when this mode is activated, and it is flashing on the FELCOM 15/FELCOM 16.

CAUTION04-04-20 05:37 (UTC)SSAS Manager Mode enabled.

<Press ESC key to continue>

5. Press the [Esc] key several times to close the menu. This enables the SSAS manager mode, which allows you to execute the procedure in paragraph 3.2.

Note: Turn the power off and on again whenever changing SSAS-related settings.

16

3.2 Setting SSAS Report Destination and Message Contents

When the SSAS is activated, the SSAS report is sent according to the addresses (max. 5) and message content set with SSAS Report 1 – SSAS Report 5 on the SSAS Report menu. Note 1: The destination and message content of an SSAS report varies according to

Administration. Therefore, set them as requested by ship’s authorities. For information other than ship’s name, MMSI no. and IMN no., set it manually with “Other Inf.”

Note 2: The equipment must be in the SSAS manager mode to execute this procedure. See paragraph 3.1.2.

1. Press the [F5] to open the Reports menu. Reports

1. Data Report2. Message Report3. Data Network ID4. SSAS Report

2. Press the [4] key to shown the SSAS Report menu. SSAS Report

1. SSAS Report 12. SSAS Report 23. SSAS Report 34. SSAS Report 45. SSAS Report 56. Message Contents

3. Press [1], [2], [3], [4] or [5] key as appropriate. Note: When the button is tested on the FELCOM 12, the test report is sent to the

station having the youngest SSAS report number. Therefore set at SSAS Report 1 the station which is to receive the test report.

SSAS ReportONReal+Test

TELEX

02:00 (hh: mm)

StatusModeStation Name

Destination TypePrefix CodeCountry/Ocean CodeStation IDModem TypeAddressSubject

LES IDReport Interval

SSAS report window (FELCOM 15/FELCOM 16)

17

4. FELCOM 15/16: Press the [↓] key to choose Mode and then press the [Enter] key. FELCOM 12: Go to step 6.

Real+TestReal OnlyTest Only

5. Press the [↑] or [↓] key to choose mode desired and then press the [Enter] key. “Mode” defines what SSAS report(s) a station is to receive: Real+Test: Actual SSAS report and test SSAS report. Real Only: Actual SSAS report only. Test Only: Test SSAS report only.

6. Press the [↓] key to choose Station Name and then press the [Enter] key. 7. Press the [↑] or [↓] key to choose appropriate station and then press the [Enter] key.

You may sort the list by group name, station name or communication type as follows: Group name: Each press of [Ctrl] + [G] sorts the list by group name, ascending or descending order. Station name: Each press of [Ctrl] + [N] sorts the list by station name, in ascending or descending order. Comm. type: Each press of [Ctrl] + [T] sorts the list by communication type, in ascending or descending order.

8. Press the [↓] key to choose LES ID and then press the [Enter] key. 9. Press the [↑] or [↓] key to choose LES and then press the [Enter] key.

Note: Change the LES whenever sea area has changed. However, the equipment automatically searches for an LES with which you can communicate and the SSAS report is transmitted to that LES.

10. Press the [↓] key to choose Report Interval and then press the [Enter] key. 11. Enter time interval (00:10-99:59) to transmit the SSAS report and then press the [Enter]

key. 12. Press the [Esc] key to open the Update window .

SSAS ReportONReal+Test

TELEX

02:00 (hh: mm)

StatusModeStation Name

Destination TypePrefix CodeCountry/Ocean CodeStation IDModem TypeAddressSubject

LES IDReport Interval

Update

NoYes

FELCOM 15/ FELCOM 16 SSAS report window w/update window

13. Yes is selected; press the [Enter] key to close the SSAS report window.

18

14. Press the [6] key to display the SSAS Message Contents menu. SSAS Message Contents

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 34: 44. 46N135: 21. 26E02/04/2004 04:31:48 (UTC)071 deg 00 kt02/04/2004 04:31:48 (UTC)

Vessel Name : MMSI :IMN :Other Inf. :

LAT:LON:Time:COURSE:SPEED:Time:

15. Press the [Enter] key to open the Vessel Name window. 16 Enter vessel’s name and then press the [Enter] key. 17. Press the [↓] key to choose MMSI and then press the [Enter] key. 18. Enter MMSI number and then press the [Enter] key. 19. Press the [↓] key to choose IMN and then press the [Enter] key. 20. Enter IMN and then press the [Enter] key. 21. Press the [↓] key to choose Other Inf. and then press the [Enter] key 22. Enter appropriate message (three lines) and then press the [Enter] key.

Note: To shift between lines, use the [↑] or [↓] key. 23. Press the [Esc] key to open the Update window. 24. Yes is selected; press the [Enter] key to close the SSAS Message Contents menu. 25.Press the [Esc] key twice to return to the standby display. Note 1: To delete entered subscriber’s data, choose “Remove” from “Status.” Note 2: SSAS report settings may be saved to a floppy disk for backup.

FELCOM 15: [F8], [9], [6] to show the Save/Load window. FELCOM 16: [F8], [8], [6] to show the Save/Load window.

1. ALL2. Station List3. LES List4. E-Mail Service List5. SSAS Report*6. Other

Load from FD1. ALL2. Station List3. LES List4. E-Mail Service List5. SSAS Report*6. Other

Save to FD

*: Availlable only in SSAS manager mode("5.SSAS Report" is added in the SSAS manager mode and item numbers are shifted.)

Note 3: To confirm the settings, follow paragraph 3.5.

19

3.3 Transmitting SSAS Report In the normal mode, the SSAS report is sent 30 seconds after the button on the SSAS is pressed. The SSAS repeatedly transmits the report even if the button is pushed off ( ). Repeated transmission can only be stopped from the SSAS manager mode. 1. Open the cover of the SSAS alert button.

Cover

2. Push the button. The button is a latch-type button; hit and release the button to activate

( ) the SSAS unit. 3. The SSAS report is transmitted 30 seconds after the button is pushed in ( ). Below are

the contents of the SSAS report. - - - SSAS ALERT MESSAGE - - -Vessel Name: Queen Elizabeth 2MMSI: 111660000IMN: 443100000Help me!LAT: 34:44.46NLON: 135:21.26ETime: 02/04/2004 04:31:48 (UTC)COURSE: 071 degSPEED: 00 ktTime: 02/04/2004 04:31:48 (UTC)

Ship's NameMMSI No.IMN No.Desired messageOwn ship postion in latitudeOwn ship position in longitudeTime of position dataCourseSpeedTime of course and speed data

Note: If you accidentally push the button in, push it again within 30 seconds to cancel the report. The button pops out ( ) and the report is not transmitted. When this is done, the message “INF: SSAS UNIT activation has been canceled.” appears on the display. Additionally, for the FELCOM 16, the POWER lamp on the communication unit flashes 30 seconds.

4. An LES sends acknowledgement to your ship. 5. For multiple destinations, steps 3 and 4 are repeated. 6. The SSAS report is transmitted repeatedly while the button remains pushed in ( ). 7. To stop transmission, push the button again to pop it out ( ). (SSAS manager mode

only.)

20

Note 1: You may cancel repeated transmission from either operating mode by pushing the button OFF→ON→OFF→ON→OFF. You must allow no more than three seconds to elapse before pushing the button again. If more than three seconds elapses, repeat the procedure. When transmission is stopped, the message “INF: SSAS UNIT activation has been cancelled.” appears and, on the FELCOM 16 only, the POWER lamp on the communication unit flashes approx. 30 seconds.

Note 2: If transmission is not canceled with the button and the power is turned off, the equipment resumes repeated transmission when powered again.

21

3.4 Testing the Button The SSAS button can be tested as below. Note 1: An actual SSAS report cannot be transmitted during the testing. Note 2: The equipment must be in the SSAS manager mode to conduct the test. FELCOM 15

1. Press the [F7] key to display the Options menu. 2. Press the [7] key ([6] key when the FELCOM functions as an EGC receiver) to display

the Test menu. Test

1. PV Test2. PV Test Result3. Diagnostic Test4. Distress/SSAS Button Test

3. Press the [4] key.

1. Login2. Logout3. Abort4. Select NCS5. Ocean Region6. Test

Options

1. PV Test2. PV Test Result3. Self Test4. Distress Alarm Button Test

TestDistress/SSAS Button Test

Start

NoYes

4. Press the [Enter] key to start the test.

1. Login2. Logout3. Abort4. Select NCS5. Ocean Region6. Test

Options

1. PV Test2. PV Test Result3. Self Test4. Distress Alarm Button Test

Test

Distress/SSAS buttons are under test mode.Press any key to escape.

Distress/SSAS Button Test

CAUTIONINF: Distress/SSAS Buttons entered into TEST MODE.

<Press ESC key to continue>

The display shows the message (in red) “Distress/SSAS buttons are under test. Cancel the test mode if a real distress/SSAS needs to sent.” appears.

5. Open the button cover on the No.1 SSAS. 6. Push the button in ( ). The CAUTION window displays the message “SSAS UNIT

works correctly.” appears if the unit is functioning properly. 7. 30 seconds after the button is pushed in the SSAS test report is automatically sent to the

station(s) whose Mode set on the SSAS Report window is “Real+Test” or Test Only”. 8. Turn the button of the No. 1 SSAS off ( ).

Note: To test the No. 2 and No. 3 SSAS repeat steps 6-8.

22

9. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is stopped and the message shown below appears to notify you that normal operation has been restored.

CAUTIONINF: Distress/SSAS Buttons returned to NORMAL OPERATION.

<Press ESC key to continue>

Further, because the button remains pushed in ( ), the message “Please return the SSAS button into OFF-STATE.” appears.

10. Push the button again to pop it out ( ). 11. Close the button cover. 12. Press the [Esc] key three times to return to the standby display. Note: If the button is left pushed in ( ) when the terminal unit is turned on, the equipment

displays “Please return the SSAS button into OFF-STATE.” Push the button again to turn off ( ) the button.

23

FELCOM 16 (no PC)

Turn off communication unit.

Turn on button of No. 1 SSAS.

Turn on communication unit.

30 s

POWER, LOGIN and TX lamps flashin that order.

Send SSAStest report?

No (within 30 s)

Yes (after 30 s)

SSAS report is sent to station(s)whose mode is "Real+Test" or "Test Only". (See paragraph 3.2.) Lamps flash rapidly during TX.

Testsuccessful?

No ERROR lamp flashes rapidly.

Yes

POWER, LOGIN and TX lamps flash in that order. ERROR lamp also flashes.

Turn off button of No. 1 SSAS.

The POWER, LOGIN and TX lamps flash in that order.

Turn on button of No.2 SSAS.

Test TX

Note: If a 3rd SSAS unit is installed test it by procedure used to test No.2 unit.

Test TX

Turn off button of No.2 SSAS.

Turn communication unit off andon again.

24

FELCOM 16 (by PC)

1. Press the [F7] key to display the Options menu. 2. Press the [7] key ([6] key when the FELCOM functions as an EGC receiver) to display

the Test menu. Test

1. PV Test2. PV Test Result3. Diagnostic Test4. SSAS Button Test

3. Press the [4] key.

1. Login2. Logout3. Abort4. Select NCS5. Ocean Region6. Test

Options

1. PV Test2. PV Test Result3. Self Test4. Distress Alarm Button Test

TestSSAS Button Test

Start

NoYes

4. Press the [Enter] key to start the test.

1. Login2. Logout3. Abort4. Select NCS5. Ocean Region6. Test

Options

1. PV Test2. PV Test Result3. Self Test4. Distress Alarm Button Test

Test

Distress/SSAS buttons are under test mode.Press any key to escape.

Distress/SSAS Button Test

CAUTIONINF: Distress/SSAS Buttons entered into TEST MODE.

<Press ESC key to continue>

Test mode

The display shows the message (in red) “SSAS buttons are under test. Cancel the test mode if a real SSAS alert needs to sent.” appears.

5. Open the button cover on the No. 1 SSAS. 6. Push the button in (ON). The CAUTION window displays the message “SSAS UNIT

works correctly.” appears if the unit is functioning properly. 7. 30 seconds after the button is pushed in the SSAS test report is automatically sent to the

station(s) whose Mode set on the SSAS Report window is “Real+Test” or Real Only”. 8. Turn the button of the No. 1 SSAS off ( ).

Note: To test the No. 2 and No. 3 SSAS repeat steps 6-8.

25

9. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is stopped and the message shown below appears to notify you that normal operation has been restored.

CAUTIONINF: SSAS Buttons returned to NORMAL OPERATION.

<Press ESC key to continue>

Further, because the button remains pushed in ( ), the message “Please return the SSAS button into OFF-STATE.” appears.

10. Push the button again to pop it out ( ). 11. Close the button cover. 12. Press the [Esc] key three times to return to the standby display. Note: If the button is left pushed in ( ) when the communication unit is turned on, the

equipment will go into the test mode if the SSAS is not transmitting repeatedly. To return to the standby display, push the button again to pop it out ( ) and then turn the communication unit off and on again.

FELCOM 12

1. Press the [F7] key to open the Options menu. 2. Press the [6] key if the FELCOM 12 operates as an Inmarsat C MES or the [5] key if it

operates as an EGC receiver. Test

1. PV Test2. PV Test Result3. Diagnostic Test4. SSAS Button Test

Test menu 3. Press the [4] key.

1. Login2. Logout3. Abort4. Select NCS5. Ocean Region6. Test

Options

1. PV Test2. PV Test Result3. Self Test4. Distress Alarm Button Test

TestDistress/SSAS Button Test

Start

NoYes

Start window 4. Press the [Enter] key to start the test mode.

26

1. Login2. Logout3. Abort4. Select NCS5. Ocean Region6. Test

Options

1. PV Test2. PV Test Result3. Self Test4. Distress Alarm Button Test

Test

Distress/SSAS alert button test mode.Press any key to escape.

Distress/SSAS Button Test

CAUTIONINF: DMC/SSAS switch TEST started.

<Press ESC key to continue>

Display during testing 5. Open the cover of the No. 1 SSAS unit. 6. Press the button of the No. 1 SSAS unit to turn on ( ) the unit.

The CAUTION window displays the message “SSAS UNIT works correctly.” if the unit is functioning properly.

7. 30 seconds after the button is pushed in, the SSAS test report is automatically sent to the station specified in the youngest SSAS report number.

8. Turn the button of the No. 1 SSAS off ( ). Note: To test the No. 2 and No. 3 SSAS repeat steps 6-8.

9. After the test is completed, press the [Esc] key on the keyboard twice to return to the standby mode. The following message appears.

CAUTIONINF: DMC/SSAS switch TEST terminated.

<Press ESC key to continue>

Display at completion of test

Further, with the button left in the “ON” state ( ) the message “[Please return the SSAS button into OFF-STATE.” appears.

10. Press the button again to turn it off ( ). 10. Close the button cover. 11. Press the [Esc] key three times to return to the standby display.

Note: If you turn off the communication unit with the button of an SSAS unit turned on ( ) the message “Please return the SSAS button into OFF-STATE.” appears. Press the button to turn it off ( ).

27

3.5 SSAS Report Test You can test for successful transmission of the SSAS report to the address you specify, without using the button. The test report message states “!!! Test Call !!!” to alert the receiver of the message that it is a test call. Note: This function is only available in the SSAS manager mode. Switch to this mode (see

paragraph 3.1.2) and then follow this procedure. 1. Press the [F5] key to open the Reports menu. 2. Press the [4] key to choose the SSAS Report menu. 3. Press the [1], [2], [3], [4] or [5] key as appropriate, and the SSAS report setting menu

appears. 4. Set destination where to transmit the test. 5. Press the [↑] key to choose Status and then press the [Enter] key. 6. Press the [↓] key to choose TEST and then press the [Enter] key. 7. Press the [Esc] key to open the Update window on the FELCOM 15/FELCOM 16 or the

Entry window on the FELCOM 12. 8. Yes is selected; press the [Enter] key. The test report is transmitted. After it is

transmitted, “Status” is automatically set to ON. 9. Press the [Esc] key twice to return to the standby display.

tmatsuguchi
Mar.03'05
tmatsuguchi
miyosi
D-1
yhatai
Y. Hatai
miyosi
D-2

Apr.17'07 R.Esumi

emiyoshi
テキストボックス
D-3
yhatai
Y. Hatai
miyosi
D-4

This page is intentionally left blank.

654321

A

B

C

D

FURUNO ELECTRIC CO., LTD.

インマルサットC船舶地球局

FELCOM 15

INMARSAT-C MES

INTERCONNECTION DIAGRAM

相互結線図

101112131415

456789

123

D-sub15P

GND

TD-A

RD-B

TD-BRD-A

GNDTD/RD-ATD/RD-B

Vcc(ALM)

NC

DMC_OUT-HDMC_OUT-C

DMC_IN-CDMC_CHECK

DMC_CTRL

JUNCTION

DGPS BNC PLAG DGPSデコーダーDGPS DECODER

*1

DRAWN

CHECKED

APPROVED

SCALE

DWG No.

MASSkg

TITLE

NAME

名称

2B02

ANT

TNCP-NJ

1

6

2345

KDATNCGND+5VKCLKNC

キーボードKEYBOARDBTC-5100C PS/2

KEYBOARD

12345678

PC: CROSS CABLEHUB: STRAIGHT CABLE

E_TD_PE_TD-N

NCNCE_RD_NNCNC

E_RD_P

P

P

LAN船内LAN (HUB)

パソコンなど

LAN(HUB) OR PC, ETC.

16P0208A

1

25

57-303624VDCPRINTERPP-510

*4

プリンタ PRINTER17JE-23250-02(D8C)

1

36

*4

*2

*3*3

*3

2B03 16P0209

123

2B10 16P0214

GNDDC(-)DC(+)

12-24VDC

+-

24VDC

*3MJ-A3SPF

TPA5FB0.3NJ5FBA-5DFB,0.3m

COAX. CABLE(50Ω)

23

1

45

9

678

GND

*4

DTE

RXDTXD

CO-0.2x2P,MAX.15m*2

123

FM14-7P

0V

NC7

RXDTXD

*2

EGCプリンタ

PP-505EGC PRINTER

1234567

12345

FM14-5PRXDTXDNCNC0V

I/F BOXOP16-14

*2

*2

-02(D8C)17JE-13090

T.YAMASAKI

T.TAKENO

+-

DPYC-2.5

DPYC-4

INDC

INAC

*1

*1

24 VDC

100-115/200-230 VAC1φ,50/60Hz

12-24 VDC

銅板 COPPER STRAPW=30,1.2mOUT

シロクロ

FUSE15A(12V)7A(24V)

WHTBLK

MJ-A3SPF0018-050ZC,5m,φ11

*2SUPPLY UNITAC/DC POWER

AC/DC

PR-240

電源ユニット

PE

保護アース

*1

2m

IC-215TERMINAL UNITターミナルユニット

*5. TB BOARD (16P0116) REQUIRED.

*7. DO NOT SHORTEN ANTENNA CABLE.

NOTE

*4. GROUND THRU CONNECTOR CLAMP.

*1. SHIPYARD SUPPLY.*2. OPTION.*3. FITTED AT FACTORY.

注記

*4)コネクタクランプでアースに落とす。

*1)造船所手配。*2)オプション。*3)工場にて取付済み。

*5)TB基板(16P0116)が必要。

*6)終端のIC-307はジャンパー設定を変更する。

*7)アンテナケーブルは切断して使用しないこと。

*6. CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE.CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5

RH12BPG-3S123

BLKクロWHTシロ

REDアカ +24V0VGND

16S0184,3m,φ

8

VCTF-0.75x3C,5m,φ7(16S0084)

24 VDC 23

1

45

9

678

GND

*4

DTE

123456789

*4

RXDTXD

NC

DTR

DSR

CTSRTS

NC

パソコンPC

*217JE-573-10,5m,φ8CO-0.2x5P,MAX.15m

-02(D8C)17JE-13090 17JE-23090

-02(D8C)

GND

RXDTXD

ANTENNA UNITアンテナユニット

IC-115

RW-47470.3m

GND08S0087

12

(+)(-)

08S0157,3m24VDC

FM14-7P

IV-2sq.

P

P

123456

TB5DIST_IN-HDIST_IN-C

DIST_OUT-CDIST_OUT-H

DIST_CTRGND

DMC-5

遭難警報装置DISTRESS MESSAGECONTROLLER

1112131415

TTYCS-4*1

IC-315接続箱JUNCTION BOX

STP CABLE(CAT5) *1

8D-FB-CV,50m,φ14.3: N-P-8DFB

TP5FBAW-5DFBB,30m,φ10.7

12D-SFA-CV,100m,φ20: N-P-12DSFA

SELECT CABLE & CONNECTORケーブル/コネクタは選択

*7

101112131415

456789

123

接続箱

IC-315JUNCTION BOX

TTYCS-4(*1) ORCO-0.2x5P(*2)

*1TTYCS-4

航法装置NAV EQUIPMENT

TTYCS-1(*1) ORCO-0.2x2P(*2)

123456

SSAS_OUT-H

SSAS_IN-CSSAS_CTRLGND

SSAS_CHECKNC

P

P

P

P

12345

12345

16P0213A

16P0213B

VCCGNDTD/RD-ATD/RD-BFG

VCCGNDTD/RD-ATD/RD-BFG

遭難警報器DISTRESS ALERT/RECEIVED CALL UNIT

ALARM UNITアラームユニットIC-306

IC-305

P

P

IC-307 (No.1)SSAS ALERT UNIT保安警報発呼器

*2 *6

TTYCS-4(*1) ORCO-0.2x5P(*2)

123456

SSAS ALERT UNIT保安警報発呼器

IC-307 (No.2)*2 *6

123456

最大3台まで接続可能。MAX.3 SETS AVAILABLE.

SSAS ALERT UNIT保安警報発呼器

IC-307 (No.3)*2 *6

合計 :最大200mTOTAL: UP TO 200m

P P

P P

または OR

C5635-C01- M

Aug. 24 '07

Aug. 24 '07

*4

1234567

RXD-C+9VNC

TXD-C

RXD-HTXD-HFG

EGCプリンタ

PP-505EGC PRINTER

12

GND08S0087

(+)(-)

08S0157,3m24VDC

*2 *5

FM14-7P

*4

P

P

CO-0.2x5P,MAX.100m

*4

*4

RJ-45

Aug.27'07 R.Esumi

emiyoshi
テキストボックス
S-1

24

3

A

1

B C

MASS

名称

NAME

TITLE

kg

DRAWN

CHECKED

APPROVED

SCALE

DWG

No.

FELC

OM16

INT

ERCO

NNECT

ION

DIAG

RAM

相互

結線

CO-0.2x5P:

CO-SPEVV-SB-C0.2x5P,φ

13.5

イン

マル

サッ

トMI

NI-C

携帯

移動

地球

INMA

RSAT

MIN

I-C

MES

C5638-C01-

K

NOTE

注記

*6.

DONOT

SHORTEN

ANTENNACABLE.

*5

)終

端の

IC-307は

ジャ

ンパ

ー設

定を

変更

する

。*

6)

アン

テナ

ケー

ブル

は切断

して

使用

しな

いこ

と。

*5.

CHANGE

SETTING

OF

JUMPERINIC-307

TOTERMINATE.

*4.

STANDARD

SUPPLY

FOR

SSASSPEC.

*3.

FITTED

AT

FACTORY.

*2.

OPTION.

*1.

SHIPYARD

SUPPLY.

*1

)造

船所

手配

。*

2)

オプ

ショ

ン。

*3

)工

場に

て取

付済

み。

*4

)SSAS仕

様時

標準

支給

Apr.

24

'07

T.YAMASAKI

Apr.

24

'07

T.TAKENO

10

11

12

13

14

154 5 6 7 8 91 2 3

GND

D-sub15P

Vcc(6.5V)

TX/RX-A

TX/RX-B

SSAS_OUT-H

SSAS_CHECK

SSAS_IN-C

SSAS_CTRL

SSAS

GND

1 2 3 4 5 6 7 8 9

パソコン

PC

RXD

TXD

NC

DTR

DSR

CTS

RTS

NC

*3

2 31 4 5 6 7 8 9

*3

*3

17JE-23090

-02(D8C)

-02(D8C)

17JE-13090

17JE-573-10,5m,φ8

*2

GND

RXD

TXD

1 2 3BLK

クロ

GND

DC(-)

DC(+)

12-24VDC

アカ

REDFM-C3FP

2B1016P0227

FUSE

10A:12VDC

5A:24VDC

FM-C3FPS-002,3.5m,φ

7.5

12-24

VDC

*3

ANT

2B0216P0208B

TNCP-NJ

ANTENNA

UNIT

アン

テナ

ユニ

ット

IC-116

TPA5FB0.3NJ5

FBA-5DFB,0.3m

RW-4747

0.3m

IC-216

通信制御ユニット

COMMUNICATION

UNIT DTE

銅板

COPPER

STRAP

W=30,1.2m

TP58A15W-RG58,15m,φ

5TP5FBAW-5DFBB,30m,φ

10.7

8D-FB-CV,50m,φ

14.3:N-P-8DFB

12D-SFA-CV,100m,φ

20:N-P-12DSFA

ケー

ブル

/コ

ネク

タは

選択

SELECTCABLE&CONNECTOR

*6

+ -24VDC

OUT

SUPPLYUNIT

AC/DCPOWER

AC/DC

*2

電源

ユニット

+ -

ACIN

DCIN

PE

保護

アー

*1

PR-240

,50/60Hz

100-115/

24

VDC

200-230

VAC

DPYC-4

DPYC-2.5

*1*1

IV-2sq.

NC

NC

NC

NC

NC

NC

NC

10

11

12

13

14

154 5 6 7 8 91 2 3

DMC_OUT-H

DMC_OUT-C

DMC_IN-C

DMC_CTR

DMC_IN-H

GND

TD/RD-A

TD/RD-B

NC

TD-A

TD-B

RD-A

RD-B

GND

Vcc

接続箱

JUNCTION

BOX

IC-315

*4

2m

1 2 3 4 5 6

SSAS_OUT-H

SSAS_IN-C

SSAS_CTRL

GND

SSAS_CHECK

NC

P

P

合計

:最

大200m

TOTAL:UPTO200m

TTYCS-4(*1)ORCO-0.2x5P(*2)

IC-307(No.1)

SSASALERTUNIT

保安

警報

発呼

*4

SSASALERTUNIT

保安

警報

発呼

IC-307

(No.2)

*4*5

MAX.3UNITSAVAILABLE

最大

3台

まで

接続

可能

1 2 3 4 5 6

1 2 3 4 5 6

SSASALERTUNIT

保安

警報

発呼

IC-307(No.3)

*2

*5

P

P

P

P

May.9'07 R.Esumi

emiyoshi
テキストボックス
S-2

This page is intentionally left blank.

相互結線図

INTERCONNECTION DIAGRAM

FELCOM 12

INMARSAT-C MES

654321

A

B

C

D

FURUNO ELECTRIC CO., LTD.

DRAWN

CHECKED

APPROVED

SCALE

DWG No.

MASSkg

TITLE

NAME

名称 インマルサットC船舶地球局

C5613-C01- J

K.MIYAZAWA

TAKAHASHI.T

5D-FB-CV,30m: N-P-5DFB-1

NJ-8DFB-1

ANT

J1N-H1054,0.3m

12D-SFA-CV,100m: N-P-120DSFA8D-FB-CV,50m: N-P-5DFB

ケーブル:コネクタ(選択)CABLE: CONNECTOR (SELECTED)

IC-112ANTENNA UNITアンテナユニット

RW-47470.37m

CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5

P

P

1234

NMEASRCN-6A16-10P J6

TXD-HTXD-CRXD-HRXD-C

10

CO-0.2x2P

(NMEA0183)

航法装置NAV EQUIPMENT

TTYCS-4(*2) OR

*4

P

P

12345

SRCN-6A16-7P

67

RCV BZ

J7*2

RBOUT-HRBOUT-CRBIN-HRBIN-CRBCTR

TTYCS-416P0150 123456

TB

SHIELD

着信指示器RECEIVED CALL UNIT

IC-303

*4

P

P

12345

SRCN-6A16-7P

67

DMC1

DMCOUT-HDMCOUT-CDMCIN-HDMCIN-CDMCCTR

J8*2TTYCS-416P0150 1

23456

TB

SHIELD

遭難警報発呼器DISTRESS ALERT UNIT

IC-302

*4

P

P

12345

SRCN-6A16-7P

67

DMCOUT-HDMCOUT-CDMCIN-HDMCIN-CDMCCTR

DMC2

J9*2TTYCS-4

SAME AVOBE同上

遭難警報発呼器DISTRESS ALART UNIT

IC-302

*4

IC-212

通信制御ユニットCOMMUNICATION UNIT

23

1

4

6

8

J3

7

5

FGRDSDCS

ERRS

SG

2025

RS-422 データ出力装置RS-422 DATA

DATA OUT(+)DATA OUT(-)CONT OUT(+)CONT OUT(-)DATA IN(+)DATA IN(-)CONT IN(+)CONT IN(-)

FGSG

*4

RS-232C KS-10PTI/F UNIT

*3インターフェイス

RS-422

23

TXDRXD

1

45GND

9

678

PC/DATA

J5

*4

17JE-23090-02(D8C)*1

*2TTYC-1

100VAC,1φ,50/60HzDPYC-1.5*2

123

J2

4

+24V+24V0 V0 V

WHTシロ

BLKクロWHTシロ

BLKクロ

*1HS16P-4 24VDC

VCTF-1.25x4C,3m,φ

11.5

16S0042

24 VDC

+-

+-

24VDCOUTPUT

24VDC

INPUT

INPUT

SUPPLY UNITAC/DC POWER

AC/DC電源ユニット

PR-300 *3 *5

*2

*2DPYC-4

DPYC-1.5

GNDIV-8SQ.

*2

24 VDC

1φ,50/60Hz

100/110/200/220 VAC

05-003-0031,1.2m

銅板W=30GND

COPPER STRAP

FOR MAIN DTEメイン端末装置用

23

TXDRXD

1

45GND

9

678

J3

DTE-1

*4

17JE-573-10,5m,φ817JE-23090-02(D8C)

123456789

RXDTXDDTR

DSR

CTSRTS

*4

1

6

2345

1

25

PRINTERCN3

*4

*117JE-23250-02(D8C)

NCDATAVCCGNDNC

CLOCK

DCD

GND

R1

COM1 KEYBOARD キーボードKEYBOARDBTC-5100C PS/2

24VDC

12 (-)

(+)J1FM14-2P

*1

BLKクロWHTシロ

17JE-13090-02(D8C)*1

16S0184,3m,φ8

*1

57-3036*1

1

36

*4

クロ

シロ

アカ

1 2 3BLK

WHT

RED

RM12BPG-3S

J1+24V

0VGND

PP-510

プリンタPRINTER

*3

24VDC

GND08S0087,2m

*4

05S0441

VCTF-0.75x2C,3m,φ

7

Dsub36P

PRINTERSWITCH

KSA-CE412L

プリ

ンタ

切替

器 *3

Dsub36P

*1

*1

16S0083,0.2m

5m57FE-336-205W

VCTF-0.75x3C,5m,φ716S0084

ターミナルユニットTERMINAL UNIT

123456789

*4

17JE-13090-02(D8C)*1

FOR SECOND DTE第2端末装置用

23

TXDRXD

1

45GND

9

678

DTE-2

J4

*4

17JE-573-10,5m,φ817JE-23090-02(D8C)

RXDTXDDTR

DSR

CTSRTS

DCD

GND

R1

COM1

TERMINAL UNIT

ターミナルユニット

*1

GND08S0087,2m

*1FM14-2P

24VDCVCTF-0.75x2C,3m,φ7

CO-0.2x2P,MAX.15m

17JE-23250-02(D8C)*1

*157-3036

PRINTERプリンタ16S0184,3m,φ8

123456

SSAS_OUT-H

SSAS_IN-CSSAS_CTRLGND

SSAS_CHECKNC

TB123456

SSAS_OUT-H

SSAS_IN-CSSAS_CTRLGND

SSAS_CHECKNC

TB123456

SSAS_OUT-H

SSAS_IN-CSSAS_CTRLGND

SSAS_CHECKNC

TBIC-307 (No.1)

SSAS ALERT UNIT保安警報発呼器

SSAS ALERT UNIT保安警報発呼器

IC-307 (No.2)SSAS ALERT UNIT保安警報発呼器

IC-307 (No.3)

P

P

23

TXDRXD

1

45 GND6789

J1

23

1

GND

+24V0V

MJ-A3SPFD 24VDC

シロクロ

WHTBLK

*1

FUSE

MJ-A3SPF00163.5m,φ11

24VDC

SSAS ALERT UNIT I/FIC-312

保安警報発呼器インターフェイス

45

123

TBSSAS_OUT-H

SSAS_IN-CSSAS_CTRL

6GND

SSAS_CHECKNC

TTYCS-4,φ16.3 OR CO-0.2x5P*2

TOTAL:MAX.200m合計 : 大200m

17JE-13090-02(D8C)17JE-573-10,5m,φ8

17JE-23090-02(D8C)*1

PC/DATA

OR

DTE-2*3 *6 *3 *6 *3 *6

0.5A

I/F BOXOP16-14 *3

FM14-7P EGCプリンタEGC PRINTERPP-505 *3

*2DPYC-1.5 24VDC

CO-0.2x5P,MAX.100mFM14-7P

FM14-5P

*3

Jun. 3 '04

17JE-23250-02(D8C)*7

IB-581/582

*3IB-581/582

*1)工場にて取付済み。*2)造船所手配。*3)オプション。*4)コネクタクランプでアースに落とす。*5)船内電源に応じてタップを替える。

終端のIC-307はジャンパー設定の変更が必要。

注記

*6)2台または3台接続可能。

*1. FITTED AT FACTORY.*2. SHIPYARD SUPPLY.*3. OPTION.*4. GROUND THRU CONNECTOR CLAMP.*5. CHANGE TAP CONNECTION IN ACCORDANCE WITH AC MAINS.

CHANGE JUMPER SETTING IN LAST IC-307.*6. 2 OR 3 SETS CAN BE CONNECTED.

NOTE

*7)コネクタの取り替えが必要。 *7. REPLACE CONNECTOR.

17JE-573-10,5m,φ8

yhatai
Y. Hatai
miyosi
S-3