shenzhenpecrontechnologyco.,ltd ... › web › userfiles › download › q2000sq3000s...8...

13
ShenZhen Pecron Technology CO.,LTD. Outdoor Portable Power Station Specification ModelQ2000S/Q3000S Thanks a lot for your choice pecron Q2000S/Q3000S Please read the manual carefully before you use! Shenzhen Pecron Technology Co.,LTD Webwww.percron.com

Upload: others

Post on 07-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ShenZhenPecronTechnologyCO.,LTD ... › web › userfiles › download › Q2000SQ3000S...8 Chargingtime 8~9H 11-12H 9 UPSFunction NO 10 Protection Over-voltage,overtemperature,overloadandshort

ShenZhen Pecron Technology CO.,LTD.

Outdoor Portable Power Station SpecificationModel:Q2000S/Q3000S

Thanks a lot for your choice pecron Q2000S/Q3000S

Please read the manual carefully before you use!

Shenzhen Pecron Technology Co.,LTD

Web: www.percron.com

Page 2: ShenZhenPecronTechnologyCO.,LTD ... › web › userfiles › download › Q2000SQ3000S...8 Chargingtime 8~9H 11-12H 9 UPSFunction NO 10 Protection Over-voltage,overtemperature,overloadandshort

Shenzhen Pecron Technology Co.,Ltd

POWER IT POSSIBLE

Shenzhen Pecron Technology Co.,Ltd http;//www.pecron.com Tel:0755-28601668 - 1 -

Contents

1. Product introduction..........................................................................................- 2 -

2. Product function description.......................................................................... - 3 -

Panel function description................................................................................... - 3 -

3. Technical specification..................................................................................... - 4 -

4. Environment Conditions...................................................................................- 5 -

5. Electricity specification.................................................................................... - 5 -

5.1-5.3 Parameter Specification........................................................................- 5 -

5.4-5.6 Protection Instructions...........................................................................- 6 -

6. Operation instructions and precautions......................................................- 7 -

6.1 How To Use AC.............................................................................................- 7 -

6.2 How to operate.............................................................................................. - 8 -

6.3 How to charge the power pack................................................................... - 9 -

7. Function Testing............................................................................................... - 10 -

7.1 Testing Conditions...................................................................................... - 10 -

7.2 Testing for basic functions.........................................................................- 11 -

8. Common problems and solutions............................................................... - 12 -

9 . Package information.......................................................................................- 12 -

Page 3: ShenZhenPecronTechnologyCO.,LTD ... › web › userfiles › download › Q2000SQ3000S...8 Chargingtime 8~9H 11-12H 9 UPSFunction NO 10 Protection Over-voltage,overtemperature,overloadandshort

Shenzhen Pecron Technology Co.,Ltd

POWER IT POSSIBLE

Shenzhen Pecron Technology Co.,Ltd http;//www.pecron.com Tel:0755-28601668 - 2 -

1. Product introductionQ2000S/Q3000S is a multiple and portable AC-DC outdoor mobile emergency powergenerator. Built in safe lithium-ion cell and high-efficiency SPWM invertertechnology,light weight,large capacity, high power, a standby power station.It canhelp you provide the mobile portable power solutions,which is widely used in the fieldof mobile office working,medical rescue,fire emergency rescue,power equipmentrepair,environment protection of land, emergency communication protection, backuppower and somewhere lack of power energy.The functions are as below:♦ 220V/50Hz or 110V/60Hz pure-sine wave AC output;♦ Uninterruptible Power Supply;♦ USB*2(QC3.0);♦ Smart display shows the battery capacity, input output power and remainingworking hours;Q2000S/Q3000S meets the demand of most of electric appliances power supply.Likemobile phones,satellite phones,digital camera,mobile hard disk,tablet computer,LEDlamp,laptop computer, car boot,outdoor lighting,waterpump,telecommunications,medical equipment,etc.It can also used in the fields of finance, first aid, mining,exploration, military, media,science,tourism, disaster relief,medial aid andsomewhere lack of power energy.

Page 4: ShenZhenPecronTechnologyCO.,LTD ... › web › userfiles › download › Q2000SQ3000S...8 Chargingtime 8~9H 11-12H 9 UPSFunction NO 10 Protection Over-voltage,overtemperature,overloadandshort

Shenzhen Pecron Technology Co.,Ltd

POWER IT POSSIBLE

Shenzhen Pecron Technology Co.,Ltd http;//www.pecron.com Tel:0755-28601668 - 3 -

2. Product function descriptionPanel function description

◆ DC Cigarette Lighter Socket:Output Voltage DC12V/Output Current

10A(MAX)

◆ USB(QC3.0) socket:When turn on DC switch, it can charge DC appliances

(DC5V/2.1A 9V/2A 12V/1.5A).

◆ Smart display: showing the battery capacity, percentage,power and time ofcharging and discharging◆ USB Output/Power switch : Press this button to view the remaining power ofthe power unit. At the same time, the display will turn on, as same as the USBoutput.If need to turn off it,please press it again.

Page 5: ShenZhenPecronTechnologyCO.,LTD ... › web › userfiles › download › Q2000SQ3000S...8 Chargingtime 8~9H 11-12H 9 UPSFunction NO 10 Protection Over-voltage,overtemperature,overloadandshort

Shenzhen Pecron Technology Co.,Ltd

POWER IT POSSIBLE

Shenzhen Pecron Technology Co.,Ltd http;//www.pecron.com Tel:0755-28601668 - 4 -

◆DC charging ports (1, 2 is positive, 3, 4 is negative): charging voltage rangeis DC 29.4V-40V20A.(solar charging)◆ AC outputs : supply output after pressing the AC switch.◆ AC switch: Turn on the AC button it works, press again it will turn off.

3. Technical specification

NO. Model Q2000S Q3000S

1 Continuousoutput power 2000W

2 Peak power 4000W

3 Out voltage AC pure-sine wave 220V/50HZ or AC 110V/60HZ

DC 12V10A QC3.0(5V2A~12V1.5A

4 Battery type 18650-28P7S( 3.7V2600mAh)

18650-40P7S( 3.7V2600mAh)

5 Battery capacity 1885.52Wh(25.9V72.8Ah) 2693.6Wh(25.9V104Ah)6 Battery life 70%@1000cycle

7 Charging voltageand current

DC 29.4V10A,DC29.4-40V20A(solar charging)

8 Charging time 8~9H 11-12H

9 UPS Function NO

10 Protection Over-voltage, over temperature,overload and shortcircuit, automatic recovery

10 Use Environment 0℃ ~ 45℃(charging)-20℃ ~ 60℃(discharge)

11 Heat-Dissipation Cooling fan12 Dimension(mm) (L*W*H)400*245*272mm13 Shell material UL94-V0 PC+ABS cold rolled plate14 Net Weight(kg) 23 27

Page 6: ShenZhenPecronTechnologyCO.,LTD ... › web › userfiles › download › Q2000SQ3000S...8 Chargingtime 8~9H 11-12H 9 UPSFunction NO 10 Protection Over-voltage,overtemperature,overloadandshort

Shenzhen Pecron Technology Co.,Ltd

POWER IT POSSIBLE

Shenzhen Pecron Technology Co.,Ltd http;//www.pecron.com Tel:0755-28601668 - 5 -

4. Environment Conditions

5. Electricity specification5.1-5.3 Parameter Specification

NO. Test Item Parameter Unit Remarks1 Use

Environment 0 ~45 ℃

2 StorageEnvironment -20 ~ 60 ℃

3 Humidity 45% ~ 85% RH4 Cooling method Air cooling Heat radiation≥45℃5 Altitude 3000 m6 MTB ≥5000 H

NO. Test Item Parameter Unit Remarks5.1 AC Adapter5.1.1 Rated voltage 100V ~ 240V VAC5.1.2 Rated frequency 50/60 Hz5.1.3 Charging voltage 29.4 VDC5.1.4 Charging current ≤10 A5.1 Solar charging input5.1.1 Load voltage 29.4-40V VDC open-circuit voltag

e≤44V5.1.2 Current ≤20 A5.2 AC Output5.2.1 Rated voltage 220/110±5% VAC5.2.2 Rated frequency 50/60±1% Hz5.2.3 Rated power 2000 W5.2.4 Harmonic distortion <3%5.2.5 Converter efficiency ≥85%5.3 DC Output5.3.1 USB voltage 4-12 VDC QC3.05.3.2 USB current 0-2.1 A QC3.05.3.3 Cigarette Lighter DC output voltage 12±5% V5.3.4 Cigarette Lighter DC output current 10 A

Page 7: ShenZhenPecronTechnologyCO.,LTD ... › web › userfiles › download › Q2000SQ3000S...8 Chargingtime 8~9H 11-12H 9 UPSFunction NO 10 Protection Over-voltage,overtemperature,overloadandshort

Shenzhen Pecron Technology Co.,Ltd

POWER IT POSSIBLE

Shenzhen Pecron Technology Co.,Ltd http;//www.pecron.com Tel:0755-28601668 - 6 -

5.4-5.6 Protection Instructions

NO . Test item Parameter Unit Remarks5.4 Inverter

5.4.1 Over temperatureInvertercooling≥

65℃℃ AC no output, until the

temperature drops

5.4.2 Over load 2000 WLock-up; No output,until

disconnected andrestarted

5.4.3 AC output short circuit — W Lock-up; No output,untildisconnected

Remark 5.5.2 5.5.3 During protection, AC on/off button needed turn off, whenrestart AC output will be turned on.

5.5 Controller

5.5.1 USB over-current 3 A Output turns off afterover-current

5.5.2 12V output over-current — A Output turns off afterover-current

5.6 Battery packs

5.6.1 Single-cell overchargevoltage protection 4.2V V Turn off charging and

keep output

5.6.2Single-cell overdischarge voltage

protection2.8V V Shutdown output

5.6.3 Battery packs overtemperature protection ≥65 ℃ Shutdown input and

output

5.6.4 Short circuit protection YES Shutdown output aftershort circuit

5.6.5 Battery packsover-current protection 220-280 A Shutdown output after

over-current

Page 8: ShenZhenPecronTechnologyCO.,LTD ... › web › userfiles › download › Q2000SQ3000S...8 Chargingtime 8~9H 11-12H 9 UPSFunction NO 10 Protection Over-voltage,overtemperature,overloadandshort

Shenzhen Pecron Technology Co.,Ltd

POWER IT POSSIBLE

Shenzhen Pecron Technology Co.,Ltd http;//www.pecron.com Tel:0755-28601668 - 7 -

6. Operation instructions and precautionsTo ensure safe transportation of the Q2000S/Q3000S, the battery is not full of power

or in the low power mode during the transportation. Please charge the device by the

original charging cable when you need to use it at the first time.During charging, the

lcd display will keep red light on; When it is fully charge, the light change as green

color.

Please use the original charging cable to ensure the safety. When the power is fully

charged, the charger will automatically stop working and the display indicator will turn

off.

6.1 How To Use AC

Please read the following information before using:

(1)The input voltage and frequency of appliances should be same with

Q2000S/Q3000S.

(2)Please ensure the rated power is lower than the output power 2000W.

* The appliance will be damaged once cannot meet the above requirements.

* Please choose another portable power pack with higher power once the power of

appliances is higher than that of 2000W

Remarks:Since the consumed power of some appliances is greater than its rated

power on power-on, like, the starting curren of inductive load equipment is generally

3-8 times of it's rated power, the starting power of energy-saving light is dozens of

times of its rated power; Their starting power is much more than the instant maximum

Page 9: ShenZhenPecronTechnologyCO.,LTD ... › web › userfiles › download › Q2000SQ3000S...8 Chargingtime 8~9H 11-12H 9 UPSFunction NO 10 Protection Over-voltage,overtemperature,overloadandshort

Shenzhen Pecron Technology Co.,Ltd

POWER IT POSSIBLE

Shenzhen Pecron Technology Co.,Ltd http;//www.pecron.com Tel:0755-28601668 - 8 -

powerof the power pack therefore.Hence, the overload protection will occur and the

power is off. This power supply has overload protection, short circuit protection, over

temperature protection and automatic recovery functions.

(3)When it has the following conditions, it will stop to work and protect the device:

①Confirm that the working power of the equipment does not exceed the maximum

load power of the equipment.

②AC output or load circuit

③Internal temperature of the device is too high.

④The voltage of the internal battery is too low.

6.2 How to operateStep 1:Turn on the AC output switch, the smart display will lighting and shows thequantity of electric charge.

Step 2:Check the voltage and frequency of your loading device.

Step 3:Check the loading device power and ensure it’s not higher than the ratedpower of Q2000S/Q3000S.Step 4:Plug the loading device in the AC socket of Q2000S/Q3000S and turn on theloading device.

Step 5:Turn off the AC output switch after using it.

Step 6:Please charge Q2000S/Q3000S on time if the battery is run off or lack ofbattery so that you can use it conveniently next time!(Note:Please be sure to turn off the switch of AC buttom when you stop to use it. Or

it will be in high energy consume mode, consuming the energy in reserve.)

Page 10: ShenZhenPecronTechnologyCO.,LTD ... › web › userfiles › download › Q2000SQ3000S...8 Chargingtime 8~9H 11-12H 9 UPSFunction NO 10 Protection Over-voltage,overtemperature,overloadandshort

Shenzhen Pecron Technology Co.,Ltd

POWER IT POSSIBLE

Shenzhen Pecron Technology Co.,Ltd http;//www.pecron.com Tel:0755-28601668 - 9 -

6.3 How to charge the power pack:It can be charged by the following two ways:

(1)Charge by original charging adapter; plug the cable to AC home sockets,and theother end is connected with 29.4V input port.

+ =charging adapter

(2)Optional aviation plug, using the aviation plug side connect DC interface, the otherno interface bare wire side connect working power of the solar panel(Note: The twobare wire cannot short-circuited,please confirm the positive and negative poles andconfirm it is in insulation situation before using, so that just can plug the aviation plugin DC port.

Optional aviation plug

(3)Car charging: After starting the car engine, using the car cigarette lighter plug intothe car cigarette lighter socket, and then connect the other end of the DC output portwith our power unit, then it works.Do not use the car charger when the car is not inthe starting state.

Car charging

Page 11: ShenZhenPecronTechnologyCO.,LTD ... › web › userfiles › download › Q2000SQ3000S...8 Chargingtime 8~9H 11-12H 9 UPSFunction NO 10 Protection Over-voltage,overtemperature,overloadandshort

Shenzhen Pecron Technology Co.,Ltd

POWER IT POSSIBLE

Shenzhen Pecron Technology Co.,Ltd http;//www.pecron.com Tel:0755-28601668 - 10 -

Precautions:①Only suitable for matched power device and avoid rainy.②Please pay attention to the connection on ‘+’ and ‘-’ pole and no reversedconnection when using car charger or solar charging.③Please charge the device every 6 months to avoid power consumption due to beidle for long time.

7. Function Testing

7.1 Testing Conditions

No. Test Item Test Conditions Inspection item

1AltitudeTest

1.The pressure ≤=11.6Kpa,T=20±5℃2.no package, no electricity

1.Appearance2.Performance

2 Temp. test 1.75±2℃and40±2℃2.repeated test for 10 times3.switching time is 30mins

1.Appearance2.Performance

3Vibration test

Amplitude:1.52mm;Scan frequency range: 5Hz~10Hz, scanspeed: about 10㎡/s3;Scan frequency range: 0Hz~200Hz,scan speed: about 3㎡/s3,Scan frequency range: 200Hz~500Hz,scan speed: about 1㎡/s3,

Duration 20min for each X,Y and Z axis direction.No damaged of the appearance.The product can pass all function test, and thelogo, words all good well, function are all normal,no shifting inside,no noise;the screws are fastened firmly and there are noscrew loose.

1.Appearance2.Performance

Page 12: ShenZhenPecronTechnologyCO.,LTD ... › web › userfiles › download › Q2000SQ3000S...8 Chargingtime 8~9H 11-12H 9 UPSFunction NO 10 Protection Over-voltage,overtemperature,overloadandshort

Shenzhen Pecron Technology Co.,Ltd

POWER IT POSSIBLE

Shenzhen Pecron Technology Co.,Ltd http;//www.pecron.com Tel:0755-28601668 - 11 -

7.2 Testing for basic functions

7.2.1 Discharging testing

7.2.2 Charging testing

7.2.3 USB interface output testing

Page 13: ShenZhenPecronTechnologyCO.,LTD ... › web › userfiles › download › Q2000SQ3000S...8 Chargingtime 8~9H 11-12H 9 UPSFunction NO 10 Protection Over-voltage,overtemperature,overloadandshort

Shenzhen Pecron Technology Co.,Ltd

POWER IT POSSIBLE

Shenzhen Pecron Technology Co.,Ltd http;//www.pecron.com Tel:0755-28601668 - 12 -

8. Common problems and solutions

9 . Package information

Error Root Solution

No LCD display afterpressing any switch Interior battery power out Charge up

No AC output afterpressing AC switch and

warning 3 times

Interior battery lowerpower Charge up

Buzzer on 5 times( Warning )

over temperatureprotection

Reduce the working power ofthe equipment or stop using

No USB output USB Switch is off Press the usb button

NO . Packing list Quantity(pcs)1 Q2000S/Q3000S power pack 12 Charging adapter 13 Car charger 14 Solar wire(optional) 14 Manual instruction and warranty card 1

Q2000-S gross weight(kg):28.8Q3000-S gross weight(kg):32.8Carton size(mm) : L660*W395*H390