SEDECAL
Este producto ostenta una marca CE de acuerdo con las disposiciones de la Directiva 93/42/CEE del 14 de Junio de 1993 sobre Productos Médicos.This product bears a CE marking in accordance with the provisions of the 93/42/EEC MDD dated June 14, 1993.
Technical PublicationSM-0510R4
Service ManualPortable X-ray Units
Portable X-ray Units
Service Manual
SM-0510R4
REVISION HISTORY
REVISION DATE REASON FOR CHANGE
0 DEC 17, 2002 First edition.
1 MAY 7, 2003 Documentation update.
2 JUL 30, 2003 Tube Selection no more available.
3 FEB 24, 2004 SPS-HF-4.0 Addition.
4 APR 13, 2004 Error 95.
This Document is the English original version, edited and supplied by the manufacturer.
The Revision state of this Document is indicated in the code number shown at the bottom of this page.
ADVISORY SYMBOLS
The following advisory symbols will be used throughout this manual. Theirapplication and meaning are described below.
DANGERS ADVISE OF CONDITIONS OR SITUATIONS THATIF NOT HEEDED OR AVOIDED WILL CAUSE SERIOUSPERSONAL INJURY OR DEATH.
ADVISE OF CONDITIONS OR SITUATIONS THAT IF NOTHEEDEDORAVOIDEDCOULDCAUSESERIOUSPERSONALINJURY, OR CATASTROPHIC DAMAGE OF EQUIPMENT ORDATA.
Advise of conditions or situations that if not heeded oravoidedcould causepersonal injury or damage to equipmentor data.
Note . Alert readers to pertinent facts and conditions. Notes representinformation that is important to know but which do not necessarilyrelate to possible injury or damage to equipment.
Portable X-ray Units
Service Manual
SM-0510R4
SAFETY SYMBOLS
The following safety symbols will be used in the equipment.Their meaning are described below.
Attention, consult accompanying documents.
Ionizing radiation.
Type B equipment.
Dangerous voltage.
Ground.
Portable X-ray Units
Service Manual
SERVICE NOTE TOPORTABLE X-RAY UNITS
THIS PORTABLE UNIT HAS BEEN CONFIGURED,CALIBRATED AND TESTED BY THE MANUFACTURER.
IT IS READY FOR NORMAL OPERATION.NO SERVICE TASK IS REQUIRED.
REFER TO THIS SERVICE MANUAL ONLYFOR PERIODIC MAINTENANCE OR REPAIRS.
Portable X-ray Units
Service Manual
Portable X-ray Units
Service Manual
SM-0510R4 i
TABLE OF CONTENTS
Section Page
1 INSTALLATION REQUIREMENTS 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1 Altitude, Temperature and Humidity 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2 Power Line Requirements 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.3 Tools and Test Equipment 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 CONFIGURATION PROCEDURE 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1 Configuration of DIP Switches 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2 How to Enter and Store Data in Configuration Mode 4. . . . . . . . . . . . . . . . . . . . .
2.2.1 Configuration of Workstations 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.2 Configuration of mA Stations for Each Focus 6. . . . . . . . . . . . . . . . . . . .
2.2.3 X-ray Tube Selection 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.4 Time Configuration for ”Prep” and Collimator Lamp 7. . . . . . . . . . . . . . .
2.2.5 Maximum X-Ray Tube Power 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 CALIBRATION 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1 Preliminary Steps 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2 Calibration of Parameters 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2.1 Preliminary Calibration of Filament Current 10. . . . . . . . . . . . . . . . . . . . .
3.2.2 Calibration of kVp Gain 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2.3 Calibration of Filament Current (Small and Large Focal Spots) 12. . . .
3.2.4 Calibration of mA Gain 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 ADJUSTMENTS 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1 Alignment of X-Ray Beam 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1.1 Alignment of Light Field with X-Ray Field 18. . . . . . . . . . . . . . . . . . . . . . .
4.2 Field Size Indicator Test 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3 Compensation Filter 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Portable X-ray Units
Service Manual
SM-0510R4ii
Section Page
5 TROUBLESHOOTING 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1 Error Codes 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2 Parts Replacement Monoblock Unit 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.1 Portable Control Board Replacement (A3175-01) 37. . . . . . . . . . . . . . . . .
5.2.2 Control Driver Board Replacement (A3189-01) 38. . . . . . . . . . . . . . . . . . .
5.2.3 EMI Filter Replacement 40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.4 Inductance Chopper Replacement 41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.5 Rectifier Bridge Replacement 41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.6 Power Supply Replacement 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.7 Magnetothermic Replacement 43. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.8 Upper Cover Replacement 43. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.9 Lower Cover Replacement 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.10 Overlay Replacement 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.11 Handswitch Replacement 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.12 Handswitch Support Replacement 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.13 Power Line Cable Replacement 45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.14 Handle Replacement 45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.15 HV Tank Replacement 46. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.16 Collimator Replacement 47. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3 Parts Replacement for SPS Unit 48. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.1 Portable Control Board Replacement (A3175-01) 49. . . . . . . . . . . . . . . . .
5.3.2 EMI Filter Replacement 49. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.3 Inductance Chopper Replacement 50. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.4 Extensora Board Replacement (A3554-02) 50. . . . . . . . . . . . . . . . . . . . . .
5.3.5 Magnetothermic Replacement 51. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.6 Power Supply Replacement 51. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.7 Rectifier Bridge Replacement 52. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.8 Handswitch Replacement 52. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.9 Overlay Replacement 52. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.10 Power Line Cable Replacement 53. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.11 Power Module with Covers, Signal Cable and HV Tank Replacement 53
5.3.12 Upper Cover Replacement 53. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.13 Lower Cover Replacement 54. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.14 Signal Cable Replacement 54. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Portable X-ray Units
Service Manual
SM-0510R4 iii
Section Page
5.3.15 Cassettes Basket Replacement 55. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.16 Gas Spring Replacement 55. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.17 Lock Lever for Wheels Arm Replacement 55. . . . . . . . . . . . . . . . . . . . . . .
5.3.18 Wheel Greentire Fusion Replacement 55. . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.19 Steering Wheel Tente Replacement 55. . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.20 Collimator Replacement 56. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 MAINTENANCE 57. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.1 Periodic Maintenance Procedures 57. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.2 General Cleaning 57. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.2.1 External Surfaces 57. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.2.2 Internal Cleaning 58. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.3 Cable Checks 58. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.4 Console Panel 58. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 RENEWAL PARTS 59. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.1 Monoblock Portable X-Ray Unit 59. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.2 Portable Mobile Column (optional for Monoblock Unit) 61. . . . . . . . . . . . . . . . . .
7.3 Portable Stand (optional for Monoblock Unit) 62. . . . . . . . . . . . . . . . . . . . . . . . . .
7.4 SPS Portable X-Ray Unit 63. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 SCHEMATICS 67. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Portable X-ray Units
Service Manual
SM-0510R4iv
Portable X-ray Units
Service Manual
SM-0510R4 1
SECTION 1 INSTALLATION REQUIREMENTS
1.1 ALTITUDE, TEMPERATURE AND HUMIDITY
All ratings and duty cycles apply to ambient temperature between 10°C and40°C, average relative humidity (no condensating) not exceeding 95% andaltitude not exceeding 4000 m above sea level.
1.2 POWER LINE REQUIREMENTS
The Unit is factory provided with a Power Cable (6 meters) and aPlug for connection to line voltage (wall socket) according tocustomer order. If required, change the line cord and plug toconform to local codes and requirements.
Portable X-ray Units power requirements are:
Maximum Power kW 2.0 2.8 4.0
Line Current at 110 VACLi C t t 230 VAC
16 A12 A
25 A12 A
32 A16 A
Line Current at 230 VACMomentary Line Current based on 100 ms X-ray exposure (RMS)
Power Line OperationConnection to standard outlets with GND that accomplished Local Regulation.
Single-Phase Line Automatic Regulation from 100 to 240¦10% VAC (50 / 60 Hz)
ACCORDING TO MDD93/42/CEE, THIS UNIT IS EQUIPPEDWITH EMC FILTERS. THE LACK OF THE PROPERGROUNDING MAY PRODUCE ELECTRICAL SHOCK TO THEUSER.
Note .
Portable X-ray Units
Service Manual
SM-0510R42
Maximum power line impedance:
0.08
0.28
0.48
0.68
0.88
1.08
1.28
1.48
1.68
1.88
2.08
2.28
2.48
2.68
2.88
3.08
3.28
3.48
3.68
90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260
LINE VOLTAGE (VRMS)
MAXIMUMPOWERLINEIMPEDANCE(OHMS)
1.3 TOOLS AND TEST EQUIPMENT
The following test equipment is required in Configuration, Calibration andTroubleshooting:
• Oscilloscope.
• Non-invasive kVp Meter.
• Digital Multimeter.
• Calculator.
Portable X-ray Units
Service Manual
SM-0510R4 3
SECTION 2 CONFIGURATION PROCEDURE
Configuration and Calibration procedures should only beperformed at field if Portable Control Board, Control Driver Boardor the High Voltage Tank are replaced or the EEPROM memoryis reset or replaced.
Configuration provides the initial settings for extended memory and checkoutprocedures that must be carried out before starting to work with the Unit.Functional characteristics of this generator are defined during Configuration.
Calibration data and some configuration data are stored in the extendedmemory area in a non-volatile memory chip (U11-EEPROM) located on thePortable Control Board.
Do not supply the main power until specifically instructed inthis document.
2.1 CONFIGURATION OF DIP SWITCHES
The Dip Switches located in the Portable Control Board (A3175-01) define theUnit configuration:
Dip Switch SW1 Description
1 ON = Service mode enabledOFF= Service mode disabled
2ON = Hardware errors disabledOFF= Hardware errors enabled
3ON = Demo mode enabledOFF= Demo mode disabled
4ON = Buzzer disabled (Except for exposure sound)OFF= Buzzer enabled
Note .
Portable X-ray Units
Service Manual
SM-0510R44
2.2 HOW TO ENTER AND STORE DATA IN CONFIGURATION MODE
Configuration data is entered from theControl Panel when the Unit is in ServiceMode. Access and configure data as indicated below:
1. Turn the Unit OFF.
2. Open the Cover and set switch S1--1 on Portable Control Board(A3175-01) in “On” position to allow the Service Mode.
3. Turn the Unit ON. A beep will sound when the Unit starts its power-uproutine and the software version (a.e. P01.03.0) is shown on the Displayof the Control Panel.
= Vers. 1, Rev. 03.0
kVp mAs
After the power-up routine the kVp Display shows “CAL” announcingthat the Unit is in Configuration and Calibration Mode.
kVp
TheUnit is equippedwith sixConfigurationgroups (C01 toC06 ) and theirsubgroups shown on the kVp Display when they are selected. (Refer toTable 2-1 “Configuration Menus”).
4. To enter or exit the Configuration menu:
a. Press and hold first “Collimator Lamp” push-button and then press“kVp Increase” push-button. Release first the “kVp Increase”push-button (two beeps sound) and then release the “CollimatorLamp” push-button (kVp Display shows C01 and both Focal SpotLeds blink).
b. Press “kVp Increase” or “kVp Decrease” push-buttons to movethrough Configuration menus to select any of them (the kVpDisplay shows menus from C01 to C06).
c. Press “Collimator Lamp” push-button to enter in the sub-menus.
d. Press “kVp Increase” or “kVp Decrease” to scroll throughsub-menus of each menu and select any of them. The desiredselection will be shown on the kVp Display.
e. Press “Collimator Lamp” push-button to exit the sub-menus.
f. Press and hold first “Collimator Lamp” push-button and then press“kVp Increase” push-button. Release first the “kVp Increase”push-button (two beeps sound) and then release the “CollimatorLamp” push-button in order to exit Configuration Mode.
Portable X-ray Units
Service Manual
SM-0510R4 5
Table 2-1Configuration Menus
Value on kVp Display DESCRIPTION NOTES
CONFIGURATION AS WORKSTATION-1
C0 1C1.1 X-ray Tube present (value not changeable)
C0.1C1.2 Device selection
C1.3 Not used Values factory set.O i i l l t t b difi d
CONFIGURATION AS WORKSTATION-2Original values must not be modified.Refer to Section 2.2.1
C0 2C2.1 X-ray Tube present (value not changeable)
Refer to Section 2.2.1
C0.2C2.2 Device selection
C2.3 Not used
mA STATION CONFIGURATION FOR EACH FOCUS Refer to Section 2.2.2
C0.3C3.1 mA Stations for “Small Focal Spot”
Set Maximum mA station for “Small FocalSpot”
C3.2 mA Stations for “Large Focal Spot”Set Minimum mA Station for “Large FocalSpot”
C0 4X-RAY TUBE LIST SELECTION Refer to Section 2.2.3
C0.4C4 1 X ray Tube Configuration C t b difi d R f t S ti 2 2 3C4.1 X-ray Tube Configuration Can not be modified. Refer to Section 2.2.3
TIME CONFIGURATION FOR “PREP” AND COLLIMATOR LAMP Refer to Section 2.2.4
C0.5 C5.1 “Prep” Time Configuration Factory Configured at 30 seconds.
C5.2 “Collimator Lamp” Time Configuration Factory Configured at 20 seconds.
MAXIMUM X-RAY TUBE POWER Refer to Section 2.2.5
C0.6C6.1 Maximum percentage limit for X-Ray Tube
Select the maximum power percentage at 70,80, 90 or 100.
2.2.1 CONFIGURATION OF WORKSTATIONS (1) -- (2)
Workstation-1 or Workstation-2 can be selected in this Unit. To toogle betweenWorkstations, press and hold “Collimator Lamp” button and press “kVpDecrease” button, the display shows “ST 1” (for Workstation-1) or shows “ST2” (for Workstation-2). Inform the operator about the possibility of usingWorkstation-1 andWorkstation-2, keep inmind thatwhenever theUnit is turnedON Workstation-1 is selected by default.
In case the Workstation for the Digital Receptor or Bucky isselected andnoDigital Receptor or Bucky is connected to theUnitor the connection is malfunctioning, error code “E24” appears onDisplay. Press the “Collimator Lamp” button and checkconnections and signals of theDigital Receptor or Bucky, or selectthe Workstation for Direct if no Receptor is needed.
Note .
Portable X-ray Units
Service Manual
SM-0510R46
In case a Workstation configuration needs to be modified:
1. Enter Configuration Menu C0.1 (for Workstation-1) or C0.2 (forWorkstation-2).
2. Enter sub-menu C1.2 or C2.2. The kVp Display shows (C1.2) or (C2.2)and the mAs Display shows (0) or (1). Device value is “0” for Direct (film)or “1” for Digital Receptor or Bucky. Value by default is “0” in bothsub-menus.
3. Press “mAs Increase” to change the corresponding value from “0”(Direct) to “1” (Digital Receptor or Bucky) or viceversa.
4. Press any “Focal Spot” to save value. Now Exit Configurationmode andturn the Unit OFF / ON.
2.2.2 CONFIGURATION OF mA STATIONS FOR EACH FOCUS
1. Enter Configuration menu C03.
2. Enter sub-menu C3.1. The kVp Display shows (C3.1) and the mAsDisplay shows (20.0).
3. To change the corresponding maximum value of mA station for SmallFocus, press “mAs Increase” or “mAs Decrease”. Factory default valueis 20 mA.
4. Press any “Focal Spot” push-button to save value.
5. Press “kVp Increase”, the kVpDisplay shows sub-menu (C3.2) andmAsDisplay shows (5.00).
6. Press “mAs Increase” or “mAs Decrease” to select the correspondingminimum value of mAStation for the Large Focus. Factory default valueis 5 mA.
7. Press any “Focal Spot” to save value.
8. Press “Collimator Lamp” push-button to exit the sub-menus. The kVpDisplay shows (C03).
MaximummAstation recommended for the ”Small Focus” is 20.0.TheminimummAvalue for “LargeFocus” should be the lowestmAstation allowed by the Unit.
Note .
Portable X-ray Units
Service Manual
SM-0510R4 7
2.2.3 X-RAY TUBE SELECTION
This sectiononly appliesafter a softwareupgrade.E08mayappear and requestto set index in “1” .
1. Select Configuration menu C04.
2. Enter sub-menu C4.1. The kVp Display shows (C4.1) and mAs Displayshows the Tube Index.
3. To change the X-ray Tube Index (shown on the kVpDisplay for seconds)press “mAs Decrease” and set “1”.
4. Press any “Focal Spot” push-button to save data. The Tube identification(ID) is momentarily shown on the kVp Display and a beep sounds.
5. Press “Collimator Lamp” push-button to exit the sub-menus. The kVpDisplay shows (C04).
TheUnit automatically resets theHeatUnits (%HU)maximumcapacity when the Unit is turned off or when another type oftube is configured.
2.2.4 TIME CONFIGURATION FOR “PREP” AND COLLIMATOR LAMP
1. Select configuration menu C05.
2. Enter sub-menu C5.1 for Prep Time Configuration. The kVp Displayshows (C5.1) and the mAs Display shows (30).
3. Press “mAs Increase” o “mAs Decrease” to change Preparation Time.Value Factory set at 30.
4. Press any “Focal Spot” push-button to save value.
5. Press “kVp Increase” to enter sub-menu C5.2 for Collimator Lamp Time.The kVp Display shows (C5.2) and mAs shows (20).
6. Press “mAs Increase” or “mAs Decrease” to change Collimator LampTime. Value Factory set at 20 seconds.
7. Press any “Focal Spot” to save value.
8. Press “Collimator Lamp” push-button to exit sub-menus. The kVpDisplay shows (C05).
Portable X-ray Units
Service Manual
SM-0510R48
2.2.5 MAXIMUM X-RAY TUBE POWER
The maximum X-Ray Tube Power (power curves) can be set at70, 80, 90 or 100% of the maximum rate. This power limitationincreases the total life of the Tube.
1. Select Configuration menu C06.
2. Enter sub-menu 6.1. The kVpDisplay shows (C6.1) and themAsDisplayshows (100).
3. To change the Percentage Rating, press “mAs Increase” or “mAsDecrease” push-buttons (70, 80, 90 or 100). Value factory set at 100.
4. Press any “Focal Spot” push-button to save value.
5. Press “Collimator Lamp” push-button to exit Configuration sub-menus.
6. The kVp Display shows (C06). Press and hold first “Collimator Lamp”push-button and then press “kVp Increase” push-button, release “kVpIncrease” and then release “Collimator Lamp” in order to exitConfiguration Mode.
Note .
Portable X-ray Units
Service Manual
SM-0510R4 9
SECTION 3 CALIBRATION
The Calibration process is as follows:
CALIBRATION PROCESS
STEP ACTION COMMENTS
1Connection of the Oscilloscope for kVp and mAmeasurements.
for kVp: 1 V = 10 kVfor mA: 1 V = 10 mA
2 Preliminary calibration of Filament Current.Minimum mA station in Large Focus at 80 kVp, 40 kVpand 110 kVp (or 100 kVp).
3 Calibration of kVp Gain. P01
4 Calibration of Filament Current.All mA stations in Small Focus and Large Focus at80 kVp, 40 kVp and 110 kVp (or 100 kVp).
5 Calibration of mA Gain. P02
The kV values to be selected in Calibration Mode are: 40, 80, 100and 110 kVp depending on the maximum kVp of the Unit.
3.1 PRELIMINARY STEPS
1. Connect Oscilloscope CH1 between TP16 (kVp) and TP13 (GND) onPortable Control Board.
2. Connect Oscilloscope CH2 between TP15 (mA) and TP14 (GND) onPortable Control Board.
3. Configure CH1 in 2V/div and CH2 in 0.5V/div. Time base in 50ms/div;trigger in Normal mode by positive edge of CH1.
4. kVp and mA relation, measured in the Oscilloscope, is as follows:
G Kvp: 1 V = 10 kV
G mA: 1 V = 10 mA
Whenever an exposure is performed during the Calibrationprocedure, elapse aminimum of 5 seconds between “PREP”and “EXP”, this will avoid undesired loss of time.
DuringCalibration procedureCollimator bladesmust be fullyclosed until otherwise instructed in this manual.
Note .
Portable X-ray Units
Service Manual
SM-0510R410
3.2 CALIBRATION OF PARAMETERS
Before calibrating kVp Gain, a calibration of the Filament Currentfor the lowest mA station in Large Focus at 80, 40 and 110 kVp (or100 kVp) must be performed. Refer to Section 3.2.1.
3.2.1 PRELIMINARY CALIBRATION OF FILAMENT CURRENT
1. Press and hold “Collimator Lamp” push-button, then press “mAsIncrease” push-button. Release first the “mAs Increase” push-button(two beeps sound). Then release “Collimator Lamp” push-button (thekVpDisplay shows 80 or 40 or 110 or 100 and one of the Focal Spot Ledsblinks).
2. Select: 80 kVp, “LargeFocal Spot” (led blinks), and the lowestmAstationin Large Focal Spot (by pressing the mAs push-buttons). DuringCalibration mAs Display shows the mA value.
3. Make an exposure and measure kVp and mA signal values with theOscilloscope.
a. Verify that both signals are flat and noiseless.
b. If the mA value obtained is not the selected, increase or decreasethe filament current value (shown on the kVpDisplay) by pressingand holding “Collimator Lamp” push-button and “kVp Increase” or“kVp Decrease”.
4. Make an exposure again to verify that the mA value in the Oscilloscopeis the one selected; if it is not, repeat the procedure to increase ordecrease the value.
5. Once the correct mA value is reached, save the value pressing“Collimator Lamp” and “mAs Decrease” (one beep will sound and thesaved value is shown on the kVp Display). It is important to write downthis data for later reference during calibration.
Once a value for filament current is saved, the value remains inmemory for the next mA station. This feature helps to save time atentering new data for the next station.
Note .
Note .
Portable X-ray Units
Service Manual
SM-0510R4 11
6. Repeat above procedure to calibrate the Filament Current for 40 kVp atthe lowest mA station in Large Focal Spot. The Filament Current valueis 1, 2 or 3 steps above the onecalibrated for 80 kVp. (Refer toTable 3-1).
7. Repeat aboveprocedure to calibrate theFilamentCurrent for 110 kVp (or100 kVp) at the lowest mA station in Large Focal Spot. The FilamentCurrent value is 1, 2 or 3 steps lower the one calibrated for 80 kVp. (Referto Table 3-1).
The calibration data for Filament Current should not be repeatedat any station.
8. Exit Calibration Mode by pressing and holding “Collimator Lamp”push-button, then press “mAs Increase” push-button. Release first the“mAs Increase” push-button (two beeps sound) and then release“Collimator Lamp” push-button.
3.2.2 CALIBRATION OF kVp GAIN
1. Press and hold “Collimator Lamp” and then press “mAs Decrease”push-button. Release first only “mAs Decrease” push-button (two beepssound) and then release “Collimator Lamp” push-button. The kVpDisplay shows P01 and one of the Focal Spot Leds blinks.
2. Press “Collimator Lamp” to enter calibration of kVp Gain (P01).
3. Place a Non-Invasive kVp meter aligned to the X-ray beam at SID100 cm. Open the light field to center it with the kVp meter.
4. Make an exposure (parameters are automatically selected: 80 kVp, 5mA(or minimum mA) and, 100 ms), read kVp and take note of the value.Enter kVp read value in the mAs Display pressing “mAs Increase” or“mAs Decrease” push-buttons.
5. Save the value by pressing any “Focal Spot” push-button. The DisplaymAs shows kVp Gain value during two seconds (this value representsthe Gain correction automatically applied, 200 is the reference value).
6. Press “Collimator Lamp” to exit from sub-menu P01.
7. Exit Calibration by pressing and holding “Collimator Lamp” push-buttonand then press “mAs Decrease”, release first “mAs Decrease” (twobeeps sound) and then release “Collimator Lamp” (kVp and mAsparameters are shown).
Note .
Portable X-ray Units
Service Manual
SM-0510R412
3.2.3 CALIBRATION OF FILAMENT CURRENT (SMALL AND LARGE FOCAL SPOTS)
The Following procedure describes the Filament Current calibration of all mAstations for both Focal Spots.
At the end of the Filament Current calibration process there aresome stations that do not admit exposure, in that cases entermanually the value following the trend. (Refer to Table 3-1 as anexample).
KEEP IN MIND THAT ALL FILAMENT CURRENTS SHOULDHAVE A VALUE, EVEN THE ONES OUT OF RANGE(EXPOSURES NOT ALLOWED). IN THAT CASES ACONTINUOUSBEEPWILLSOUNDANDTHEVALUESONTHEDISPLAYS BLINK.
1. Press and hold “Collimator Lamp” push-button, then press “mAsIncrease” push-button. Release first the “mAs Increase” push-button(two beeps sound) and then release “Collimator Lamp” push-button (thekVpDisplay shows 80 or 40 or 110 or 100 and one of the Focal Spot Ledsblinks). During Calibration mAs Display shows the mA value.
2. Select: 80 kVp, “Small Focal Spot” (led blinks), and the lowestmAstationin Small Focal Spot (by pressing the mAs push-buttons).
3. Make an exposure and measure kVp and mA signal values with theOscilloscope.
a. Verify that both signals are flat and noiseless.
b. If the mA value obtained is not the selected, increase or decreasethe filament current value (shown on the kVpDisplay) by pressingand holding “Collimator Lamp” push-button and “kVp Increase” or“kVp Decrease”.
4. Make an exposure again to verify that the mA value in the Oscilloscopeis the one selected; if it is not, repeat the procedure to increase ordecrease the value.
5. Once the correct mA value is reached, save the value pressing“Collimator Lamp” and “mAs Decrease” (one beep will sound and thesaved value is shown on the kVp Display). It is important to write downthis data on Table 3-2 for later reference.
Once a value for filament current is saved, the value remains inmemory for the next mA station. This feature helps to save time atentering new data for the next station.
Note .
Note .
Portable X-ray Units
Service Manual
SM-0510R4 13
6. Repeat the procedure to calibrate the Filament Current for 80 kVp at therest of mA stations in Small Focal Spot. The Filament Current value is 3,4 or 5 steps above the previous calibrated lower mA station at 80 kVp.(Refer to Table 3-1).
7. Repeat the procedure to calibrate the Filament Current for 40 kVp at therespective mA stations in Small Focal Spot. The Filament Current valueis 1, 2, 3 or 4 steps above the same mA station calibrated for 80 kVp.(Refer to Table 3-1).
8. Repeat the procedure to calibrate the Filament Current for 110 kVp (or100 kVp) at the respectivemAstations inSmall FocalSpot. TheFilamentCurrent value is 1, 2 or 3 steps lower than the samemAstation calibratedfor 80 kVp. (Refer to Table 3-1).
9. Select: 80 kVp, “LargeFocal Spot” (led blinks), and the lowestmAstationin Large Focal Spot (by pressing the mAs push-buttons). CalibrateFilament Current for this kVp / mA combination as indicated before forSmall Focal Spot.
10. Repeat the procedure to calibrate the Filament Current for 80 kVp at therest of mA stations in Large Focal Spot. The Filament Current value is 3,4 or 5 steps above the previous calibrated lower mA station at 80 kVp.(Refer to Table 3-1).
11. Repeat the procedure to calibrate the Filament Current for 40 kVp at therespective mA stations in Large Focal Spot. The Filament Current valueis 3, 4, 5 or 6 steps above the same mA station calibrated for 80 kVp.(Refer to Table 3-1).
12. Repeat the procedure to calibrate the Filament Current for 110 kVp (or100 kVp) at the respectivemAstations in LargeFocalSpot. TheFilamentCurrent value is 1, 2 or 3 steps lower the same mA station calibrated for80 kVp. (Refer to Table 3-1).
The calibration data for Filament Current should not be repeatedfor different kVp values at the same mA station. Write down allFilament Current data on Table 3-2 for later reference.
13. Exit Calibration Mode by pressing and holding “Collimator Lamp”push-button, then press “mAs Increase” push-button. Release first the“mAs Increase” push-button (two beeps sound) and then release“Collimator Lamp” push-button.
Note .
Portable X-ray Units
Service Manual
SM-0510R414
Table 3-1Example of calibrated data for Filament Current in a 4 kW Unit.
mA Stations 40kVp 80kVp 110 kVp (or 100 kVp)
5 mA 167 164 163
6.4 mA 170 168 167
SMALL8 mA 173 171 170
SMALLFOCALSPOT
10 mA 176 174 173 *
SPOT12.5 mA 179 177 * 176 *
16 mA 183 180 * 179 *
20 mA 187 183 * 182 *
5 mA 177 174 172
6.4 mA 180 177 175
8 mA 183 180 179
10 mA 187 184 183
12.5 mA 191 188 186
16 mA 194 191 190
LARGEFOCAL
20 mA 199 195 193FOCALSPOT 25 mA 203 199 198SPOT
32 mA 207 204 202
40 mA 212 208 206 *
50 mA 217 213 210 *
64 mA 223 217 * 214 *
80 mA 228 222 * 219 *
100 mA 235 227 * 224 *
NOTES: 1) Some of the values with * should be entered manually following the numeric trend.
2) mA and kVp ranges depend on the Portable Unit model.1.4 kW Units are calibrated only at 40 and 80 kVp.2.0 kW, 2.8 kW, 3.2 kW Units are calibrated at 40, 80 and 100 kVp.4.0 kW Units are calibrated at 40, 80 and 110 kVp.
Portable X-ray Units
Service Manual
SM-0510R4 15
Table 3-2Filament Current Calibration Data
mA Stations 40kVp 80kVp 110 kVp (ó 100 kVp)
5 mA
6.4 mA
SMALL8 mA
SMALLFOCALSPOT
10 mA *
SPOT12.5 mA * *
16 mA * *
20 mA * *
5 mA
6.4 mA
8 mA
10 mA
12.5 mA
16 mA
LARGEFOCAL
20 mAFOCALSPOT 25 mASPOT
32 mA
40 mA *
50 mA *
64 mA * *
80 mA * *
100 mA * *
NOTES: 1) Some of the values with * should be entered manually following the numeric trend
2) mA and kVp ranges depends on the Portable model.1.4 kW Units are calibrated only at 40 and 80 kVp.2.0 kW, 2.8 kW, 3.2 kW Units are calibrated at 40, 80 and 100 kVp.4.0 kW Units are calibrated at 40, 80 and 110 kVp.
Portable X-ray Units
Service Manual
SM-0510R416
3.2.4 CALIBRATION OF mA GAIN
mA Gain should be calibrated once all Filament Current stationshave been calibrated.
1. Press and hold “Collimator Lamp” and then press “mAs Decrease”push-button to enter Calibration Menu. Release first only “mAsDecrease” push-button (two beeps sound) and then release “CollimatorLamp” push-button. The kVp Display shows P01 and one of the FocalSpot Leds blinks.
2. Select sub-menu P02 by pressing the “kVp Increase” push-button (kVpDisplay shows P02).
3. Press “Collimator Lamp” to enter calibration of mA Gain (P02).
4. The Unit automatically selects: 40kVp, 20 mA, 100 ms, and Large focalSpot. Select on the kVp Display the Filament Current value (previouslycalibrated) by pressing “kVp Increase” or “kVpDecrease” push-buttons.
5. Make an exposure and measure mA signal value with the Oscilloscope.Verify that mA signal is flat and noiseless.
6. EntermA readvalue in themAsDisplaypressing “mAs Increase”or “mAsDecrease” push-buttons.
7. Save the value by pressing any “Focal Spot” push-button. The DisplaykVp shows the current exposure kVp value and the Display mAs showsmA Gain value during two seconds (this value represents the Gaincorrection automatically applied, 200 is the reference value).
8. Press “Collimator Lamp” to exit from sub-menu P02.
9. Exit Calibration by pressing and holding “Collimator Lamp” push-buttonand then press “mAs Decrease”, release first “mAs Decrease” (twobeeps sound) and then release “Collimator Lamp” (kVp and mAsparameters are shown).
ONCE THECONFIGURATIONANDCALIBRATIONPROCESSIS FINISHED, DO NOT FORGET TO SET THE DIP SW1-1 INOFF POSITION (SERVICE MODE DISABLED).
Note .
Portable X-ray Units
Service Manual
SM-0510R4 17
SECTION 4 ADJUSTMENTS
4.1 ALIGNMENT OF X-RAY BEAM
1. Place the Portable Unit in vertical position. The Unit has to be perfectlyaligned with a Cassette Film for a Cassette of 24 x 30 cm. Check with alevel correct horizontal position of both parts.
The Cassette Film used for testing can be located into anHorizontal Bucky or Cassette Tray of a Table or alone.
2. Place SID at 1 meter.
3. Turn on Collimator light and center the Collimator in relation to theCassette Film. Horizontal and transverse position of the light axesprojected by the Collimator Lampmust be in line with the film axes or filmsize edges.
If needed, modify Collimator position by carefully unscrewing andscrewing the four Centering Adjustment and Security Screws (Allen) ofCollimator.
Illustration 4-1Collimator Screws
CENTERING ADJUSTMENT AND SECURITY SCREWS
4. Position theCollimator Test Tool (RMImodel 161B) on theCassette Film.
5. Turn on Collimator light and by means of the Collimator Control Knobs,center the Collimator Test Tool with the light axes projected by theCollimator Lamp.
Note .
Portable X-ray Units
Service Manual
SM-0510R418
6. Adjust the Light Field of the Collimator Lamp to the rectangle drawninside the Collimator Test Tool.
7. Place centered the Beam Alignment Test Tool (RMI model 162A) on theCollimator Test Tool.
8. Load Cassette Film with a Film of 24 x 30 cm.
9. Make an exposure at 60 kVp / 5 mAs.
10. Process film and check that the X-ray Field falls just within the image ofthe inner rectangle of the Collimator Test Tool.
If an edge of the X-ray Field falls out of the inner rectangle means amisalignment of the Light Field respect to the X-ray Field. Themaximummisalignment allowed is 2 % of SID (for SID 1m = 2 cm tolerance).
Refer to Section 4.1.1 for alignment of Light Field with X-ray Field.
4.1.1 ALIGNMENT OF LIGHT FIELD WITH X-RAY FIELD
1. Place the Portable Unit in vertical position. The Unit has to be perfectlyaligned with a Cassette Film for a Cassette of 24 x 30 cm. Check with alevel correct horizontal position of both parts.
2. Place SID at 1 meter.
3. Position theCollimator Test Tool (RMImodel 161B) on theCassette Film.
COLLIMATOR TEST TOOL
Portable X-ray Units
Service Manual
SM-0510R4 19
4. Turn on Collimator light and center the Collimator Test Tool with the lightaxes projected by the Collimator Lamp.
5. Adjust the Light Field of the Collimator Lamp to the rectangle drawninside the Collimator Test Tool.
6. Check on the processed film the adjustment required to meet the LightField with the X-ray Field. Identify the deviation on the axes imaged onthe film.
PROCESSED FILM
PROCESSED FILM
COLLIMATED LIGHT FIELD
COLLIMATED X-RAY FIELD
LIGHT FIELD MISALIGNMENT
GOOD FIELDS ALIGNMENT
COLLIMATED LIGHT FIELD = COLLIMATED X-RAY FIELD
Portable X-ray Units
Service Manual
SM-0510R420
7. Do not remove the Collimator Test Tool from its original position andadjust the Light Field bymoving the Collimator Unit and/or theCollimatorLamp.
a. Collimator Lamp must be ON during Light Field adjustment.
b. Modify Collimator position by carefully unscrewing and screwingthe four Centering Adjustment and Security Screws (Allen) untiltheLightField coincideswith theaxes reference imaged (numbersand dots) on the processed film.
Illustration 4-2Collimator Screws
CENTERING ADJUSTMENT AND SECURITY SCREWS
c. If adjustment is still necessary, modify position of Collimator Lamp(refer to Collimator Manual).
8. Repeat exposure and procedure until the result is satisfactory. Themaximum misalignment allowed is 2 % of SID (for SID 1m = 2 cm oftolerance).
4.2 FIELD SIZE INDICATOR TEST
Before starting with the Field Size Indicator Test, the Alignment ofX-RayBeamTest and theAlignmentof LightFieldwithX-RayFieldTest should be performed.
1. Place the Portable Unit in vertical position. The Unit has to be perfectlyaligned with a Cassette Film for a Cassette of 35 x 43 cm. Check with alevel correct horizontal position of both parts.
2. Position SID at 1 meter (use the SID Metric Tape of the Unit).
Note .
Portable X-ray Units
Service Manual
SM-0510R4 21
3. Open the Collimator blades to set a Field Size of 24 x 30 cm for SID 1m.
4. Turn on Collimator light and center the Collimator in relation to theCassette Film. Horizontal and transverse position of the light axesprojected by the Collimator Lampmust be in line with the film axes or filmsize edges.
5. Load the Cassette Film with a Film of 35 x 43 cm centered.
6. Make an exposure at 60kVp, 1mAs.
7. Process film and check the following measurements known (refer toIllustration 4-3):
a. Measure the length of the X-ray Field on the Processed Film(identified as L)
b. Measure the width of the X-ray Field on the Processed Film(Identified asW)
Illustration 4-3X-ray Field Size
X-RAY FIELD SIZE ON THE FILM
FILM 35x43 cm
PROCESSED FILM
LENTH DIMENSION (L)
WIDTHDIMENSION(W
)
8. With the measurements obtained and according to the field sizeindication selected, the results should be:
G Length dimension (L) = 300 mm
G Width dimension (W) = 240 mm
9. The difference between the indicated Field Size and the obtained FieldSize may not exceed 1.5 % (rejection limit) of the SID in either direction.Therefore the deviation in any direction should not be higher than 15 mm(rejection limit) for SID at 1 meter.
10. If the deviation of Field Size Indication is out acceptance limits, it isnecessary to readjust the index of Collimator Blades Control Knobs. Forthat, loosen each Collimator Control Knob and position it according todeviation. Repeat the complete tests until the X-Ray Field Size selected(24 x 30 cm) is obtained.
Portable X-ray Units
Service Manual
SM-0510R422
4.3 COMPENSATION FILTER
The Unit allows installation of an additional Compensation Filter (99% purityAluminium Filter) at the window of the Tube-housing. Follow steps describedbelow for installation:
1. Turn the Portable Unit OFF.
2. Disassemble Collimator Cover without removing the Metric Tape.
Cover Screws
3. Loose Collimator Adjustment Screws and separate the Collimator fromthe rest of the Unit. Do not disconnect any cable.
Collimator Adjustment Screws
Portable X-ray Units
Service Manual
SM-0510R4 23
4. Remove two opposite nuts from HV Transformer at the window of theTube-housing. Install Filter and fix it with removed nuts.
Tube-Housing Nuts
Aluminium Filter
+ 0,5 mm Al
5. Re-Install Collimator and check correct Alignment of Collimator LightArea and X-Ray Exposition Area. If necessary, readjust Collimator(Refer to Collimator Manual).
6. Re-assemble external Cover.
Portable X-ray Units
Service Manual
SM-0510R424
This page intentionally left blank.
Portable X-ray Units
Service Manual
SM-0510R4 25
SECTION 5 TROUBLESHOOTING
The generator contains many self-diagnostic routines which greatly facilitatestroubleshooting. The self-diagnostic functions require proper operation of themicroprocessor.
As a general rule, the first step in any troubleshooting procedure is to verifycorrect power supply voltage.
Whenever theUnit is turnedoff,wait 5minutes before turning itON
Whenever a Portable Control Board or a Control Driver Board ora High Voltage Tank is replaced, it is necessary to perform theConfiguration and Calibration procedures.
In case theEEPROMmemory has to be reset, turn on theUnit andpress and hold “kVp Increase” and “mAs Increase” at the sametimeuntil twobeepsareheard.After that, it is necessary to performthe complete Configuration and Calibration process.
Note .
Note .
Note .
Portable X-ray Units
Service Manual
SM-0510R426
5.1 ERROR CODES
Table 5-1Error Code List
ERROR DESCRIPTION
E03 Wrong configuration of the X-ray Tube.
E06 “Exposure” or/and “Preparation” orders are activated during power-up.
E08 X-ray Tube configuration error.
E09 System error -- Power Inverter error due to overcurrent.
E10 Corrupted data in E2PROM.
E11 System error -- DC BUS error.
E12 mA is out of range during exposure or exposure has been aborted by the operator.
E13 kV is out of range during exposure or exposure has been aborted by the operator.
E15 Filament or Collimator Lamp current is out of range.
E19 mA without exposure order.
E20 kV without exposure order.
E28Inverter Overheating error. The temperature calculation for the next exposure is beyond 90oC or the presentconditions of the X-ray Unit inhibit the exposure (inverter overheated). Parameters for next exposure are temporallylimited by the generator (change the exposure parameters or wait for the X-ray Unit to cool).
E34Technique error. If it activates during exposure it means that the exposure has been interrupted by the “SecurityTimer” because of a system failure.
E36 The X-ray Tube thermostat / pressurestat is open or is not working properly. Heat Units may raise to any value.
E37
Tube Overload error. The selected technique is beyond the X-ray tube ratings or present conditions of the X-ray tubeinhibit the exposure (anode overheated). Parameters for next exposure may be temporally limited by the generator(change the exposure values or wait for the X-ray tube to cool).
Check that Heat Units available are lower than the calculated for the next exposure (Heat Units close to zero).Reduce exposure parameters or wait for the X-ray Tube to cool.
E38 System error -- Chopper failure.
E39 System error -- Power supply error.
E40 System error -- kV Unbalanced.
E47 System error.
E95 Power Line not good enough for operation.
Err rAm Defective RAM.
Portable X-ray Units
Service Manual
SM-0510R4 27
ERROR CODE : E03
DESCRIPTION : Wrong configuration of the X-ray Tube.
POSIBLE CAUSES
EEPROM not initialized
Corrupted data in EEPROM.
ACTIONS
1. Turn the Generator OFF and ON again.
2. If the equipment remains inoperative, get into configuration (C01), menuC1.1, and select “1”.
3. If still inoperative, reset the EEPROM memory (perform theConfiguration and Calibration process).
4. If the error remains, replace the Portable Control Board.
ERROR CODE : E06
DESCRIPTION : “Exposure” or/and “Preparation” orders are activated during power-up.
POSIBLE CAUSES
The microprocessor has detected “Prep” and/or “Exp” during power on.
ACTIONS
1. Check that none of the controls are pressed-down.
2. Turn the Generator OFF.
3. Check the Handswitch.
4. If the handswitch is OK, and the equipment remains inoperative, replacethe Overlay.
5. If the Unit remains inoperative, replace the Portable Control Board.
Portable X-ray Units
Service Manual
SM-0510R428
ERROR CODE : E08
DESCRIPTION : X-ray Tube configuration error.
POSIBLE CAUSES
Tube value has not been initialized or the value selected in Configuration C04is not correct.
ACTIONS
1. Turn the Generator OFF and ON.
2. If error remains, check/set “1” at configuration data in positionC04,menuC4.1.
3. If configuration data is OK, reset the EEPROM memory (perform theConfiguration and Calibration Process).
4. If error remains, replace the Portable Control Board.
ERROR CODE : E09
DESCRIPTION : Failure in Power Inverter. The instantaneous value of the output voltage ofthe inverter is too high.
POSIBLE CAUSES
• Defective X-ray Tube.
• Defective H.V. Transformer.
• Defective IGBT module.
• Defective Control Driver Board.
ACTIONS
1. Press the “Collimator Lamp” push-button. If the error code persists, turnthe Generator OFF and ON.
2. If the equipment remains inoperative, turn it OFF and contact themanufacturer.
Portable X-ray Units
Service Manual
SM-0510R4 29
ERROR CODE : E10
DESCRIPTION : EEPROM error.
POSIBLE CAUSES
Corrupted data or defective EEPROM on Portable Control Board.
Wrong software version or wrong power configuration.
ACTIONS
1. Turn the Generator OFF.
2. Check software version and system power.
3. If both are correct, reset the EEPROM (perform the Configuration andCalibration process).
4. If the error remains, replace the Portable Control Board.
ERROR CODE : E11
DESCRIPTION : Error in charge of capacitors. The voltage is not enough at the start-upThe voltage during normal functioning of the Unit is to high or too lowThe precharge Relay is open (not recoverable).If the error is due to voltage failure or to the precharge Relay the Unit will beblocked and the error is not recoverable but if the error is due to a voltageout of range, it is recoverable after pressing “Collimator Lamp”.
POSIBLE CAUSES
No voltage in the capacitor bank.
Defective Control Driver Board.
ACTIONS
1. Turn the Generator OFF and ON.
2. If the system remains inoperative, replace Control Driver Board.
Portable X-ray Units
Service Manual
SM-0510R430
ERROR CODE : E12
DESCRIPTION : Anode--Cathode current (mA) is out of range during exposition or expositionhas been aborted by the operator.
POSIBLE CAUSES
Filament current Calibrated is too low (no mA obtained).
Close loop for mA is not able to get enough Tube current (mA station wronglycalibrated).
Failure in mA Control hardware (filament hardware) or failure/noise in mAmeasurement.
Operator has released “Exposure” controls before exposure time has ended.
ACTIONS
1. Press the “Collimator Lamp” push-button. Repeat the same techniquevalues. If the error code persists, try different combinations of kV andmAvalues.
2. Check Handswitch status.
3. Re-calibrate the mA station.
4. If the error code persists, replace Portable Control Board.
ERROR CODE : E13
DESCRIPTION : Anode--Cathode voltage (kVp) is out of range during exposure or expositionhas been aborted by the operator.
POSIBLE CAUSES
Defective Tank.
Defective Portable Control Board.
Defective Control Driver Board.
Operator has released “Exposure” controls before exposure time has ended.
ACTIONS
1. Press the “Collimator Lamp” push-button. Repeat with the sametechnique values. If the error code persists try different combinations ofkV and mA values.
2. Check Handswitch status.
3. If the equipment remains inoperative, turn the Generator OFF andcontact the manufacturer.
Portable X-ray Units
Service Manual
SM-0510R4 31
ERROR CODE : E15
DESCRIPTION : Filament current is out of range during exposure or Collimator Lamp is on.
POSIBLE CAUSES
Wrong connection in Collimator cables.
Defective Filament Transformer inside the tank.
Defective Portable Control Board or Control Driver Board.
ACTIONS
1. Press the “Collimator Lamp” push-button. If the error code persists, turnthe Generator OFF and wait 30 minutes before turning it ON again.
2. If the equipment remains inoperative, contact the manufacturer.
ERROR CODE : E19
DESCRIPTION : Tube current detected (Anode-Cathode) without ”Prep” command.
POSIBLE CAUSES
Defective Control Driver Board or Portable Control Board.
ACTIONS
1. Press “Collimator Lamp”.
2. If the Error remains, turn the Generator OFF and ON.
3. If the equipment remains inoperative, contact the manufacturer.
Portable X-ray Units
Service Manual
SM-0510R432
ERROR CODE : E20
DESCRIPTION : kVp detected without “Exp.” command.
POSIBLE CAUSES
Failure in hardware or noise in kVp measurement.
ACTIONS
1. Press “Collimator Lamp”
2. Turn the Generator OFF and ON.
3. If the error remains, replace Portable Control Board.
4. If the equipment remains inoperative, contact the manufacturer.
ERROR CODE : E28
DESCRIPTION : E28 appears in Display.
POSIBLE CAUSES
Excess of exposures in short time.
ACTIONS
1. Wait 12 minutes until the error code disappears.
2. If error code has not disappeared, turn the Unit Off, wait another 12minutes and turn it On.
3. If the equipment remains inoperative, contact the manufacturer.
Portable X-ray Units
Service Manual
SM-0510R4 33
ERROR CODE : E34
DESCRIPTION : Error in Exposure timer. The Backup Timer stopped the exposure as theExposure Timer did not stopped.
POSIBLE CAUSES
Failure in Portable Control Board.
ACTIONS
1. Turn the Generator OFF.
2. Replace Portable Control Board.
3. If the equipment remains inoperative, contact the manufacturer.
ERROR CODE : E36
DESCRIPTION : Presostat/ thermostat is open. “WARNING” on Display.
POSIBLE CAUSES
X-ray Tube thermostat / pressurestat is open due to overheating or to athermostat / pressurestat malfunction. Heat Units may raise to any value.
ACTIONS
1. This error does not require “Collimator Lamp” push-button to bepressed.This indication disappear automatically.
2. If error code remains, turn the Generator OFF and contact themanufacturer.
Portable X-ray Units
Service Manual
SM-0510R434
ERROR CODE : E37
DESCRIPTION : Tube Overload error.
POSIBLE CAUSES
Either the selected technique is beyond the X-ray tube ratings or presentconditions of the X-ray tube inhibit the exposure (anode overheated).Parameters for next exposure may be temporally limited by the generator(change the exposure values or wait for the X-ray tube to cool).
ACTIONS
1. This error indication disappears automatically and does not require“Collimator Lamp” push-button to be pressed if the temperature goesdown enough as to allow another exposure.
2. If the error code persists, replace the Portable Control Board.
ERROR CODE : E38
DESCRIPTION : Failure in chopper. The voltage in DC BUS and / or the voltage in chopperCoil is too high.
POSIBLE CAUSES
Overcurrent in Chopper.
Noise in Hardware that measure this parameter.
ACTIONS
1. Press the “Collimator Lamp” push-button.
2. If the error code persists, turn the Generator OFF and contact themanufacturer.
Portable X-ray Units
Service Manual
SM-0510R4 35
ERROR CODE : E39
DESCRIPTION : Not enough voltage in +15V line.
POSIBLE CAUSESFailure or voltage dropped in +15V line.
ACTIONS
1. Press the “Collimator Lamp” push-button. If the error code persists, turnthe Generator OFF.
2. Replace Portable Control Board. If the equipment remains inoperative,contact the manufacturer.
ERROR CODE : E40
DESCRIPTION : kVp not balanced (more voltage in one of the lines (Anode or Cathode).
POSIBLE CAUSES
Failure in high Voltage Tank.
ACTIONS
1. Press the “Collimator Lamp” push-button. If the error code persists, turnthe Generator OFF.
2. Replace the High Voltage Tank. If the equipment remains inoperativecontact the manufacturer.
ERROR CODE : E47
DESCRIPTION : Hardware error (but the indication disappears before the error is identified).
POSIBLE CAUSES
Noise in the error signal. Hardware Error.
ACTIONS
1. Press the “Collimator Lamp” push-button.
2. If the error code persists, turn the Generator OFF and ON again.
3. If the Unit remains inoperative, try to reproduce the error in order toidentify which is the error signal (measure with the oscilloscope) andcheck with manufacturer.
Portable X-ray Units
Service Manual
SM-0510R436
ERROR CODE : E95
DESCRIPTION : Failure in external Power Line that inhibits any operation.
POSIBLE CAUSES
Poor quality of Electricity Line or High Line impedance.
ACTIONS
1. Turn the Unit OFF and move to another plug.
2. If the Unit remains inoperative, change to another line plug (this is not aproblem of the Unit).
ERROR CODE : RAM
DESCRIPTION : Failure in external memory or failure in internal memory of microcontroller.The Unit is blocked. At the starting-up the following is displayed:
kVp Display shows (rAm) and mAs Display shows (Err)
POSIBLE CAUSES
Defective microcontroller RAM in Portable Control Board.
Defective external RAM in Portable Control Board.
ACTIONS
1. Turn the Unit OFF and ON again.
2. If the Unit remains inoperative, change defective RAM in PortableControl Board.
Portable X-ray Units
Service Manual
SM-0510R4 37
5.2 PARTS REPLACEMENT FOR MONOBLOCK UNIT
DO NOT MANIPULATE INSIDE THE UNIT WITHOUTDISCONNECTING IT FROM MAINS, RISK OF ELECTRICSHOCK.
COLLIMATOR
POWER UNIT CONTROL DISPLAY
Refer to Renewal Parts Section for further information on partsidentification.
5.2.1 PORTABLE CONTROL BOARD REPLACEMENT (A3175-01)
1. Unscrew Upper Cover (4 Allen screws).
2. Disconnect J5, J6 (Ribbon cable) and J7 at Portable Control Board.
3. Disconnect GND wire (Allen 7) and take out the Upper Cover.
4. Disconnect J4 (Ribbon cable) at Portable Control Board.
5. Unscrew the Support (4 nuts) of the Portable Control Board.
6. Replace the Portable Control Board.
7. Re-install the parts step by step.
Note .
Portable X-ray Units
Service Manual
SM-0510R438
5.2.2 CONTROL DRIVER BOARD REPLACEMENT (A3189--01)
1. Unscrew Upper Cover (4 Allen screws).
2. Disconnect J5, J6 (Ribbon cable) and J7 at Portable Control Board.
3. Disconnect GND wire (Allen 7) and take out the Upper Cover.
4. Unscrew the round metal base of the Handswitch and take it out.
5. Unscrew the white bumpers of the Lower Cover (4 Allen screws). Takeout carefully the Lower Cover (as line cable still connected) and pass itthrough the connectors window.
6. Place the unit vertically with the Collimator on the Table.
7. Place the end of a flat screwdriver in the opening hole of theMagnetothermic, push and take it out.
8. Cut the plastic fasteners of the black wires connected to the Board.
9. Unscrew the 4 black wires and the 3 red wires attached with nuts to theControl Driver Board.
10. Take out Mylar between capacitors.
11. Unscrew the 2 Allen screws located at each side of the chassis. Theseare the screws that assemble the Connectors / Boards Support to thePortable Chassis.
12. Disconnect at the EMI Filter Board the 2 black wires from the ControlDriver Board (2 nuts).
13. Move the Connectors / Boards Support and disconnect J2 at the PowerSupply.
14. Disconnect GND wire attached to Chassis.
15. Release cables of the Thermomagnetic.
16. Unscrew the 2 Allen screws of L-shaped support of the Thermomagneticand take out J1, J3, J4 and J5 at the Control Driver Board.
17. Take out the 2 Allen screws of the Control Driver Board close toconnectors J2 and J5.
Portable X-ray Units
Service Manual
SM-0510R4 39
18. Takeout the4nuts of theControl DriverBoard (access through theBoardholes) and take out the Control Driver Board.
19. Slit the Heat Shrink cover cables of the Magnetothermic and unsolderthem fromK1onControl Driver Board. Solder the cables to K1 of the newControl Driver Board and cover them with a new Heat Shrink.
20. Pick up new Board and spread a layer of Thermic Silicone under theIGBT.
21. Place newBoard with the 4 nuts and the 2 Allen screws removed before.
22. Remove the Ribbon cable from the old Board and connect it to J2 in thenew Board.
23. Connect J1, J3 (with Ferrita), J4 and J5 in the new Board.
24. Install the L-shaped Support of the Thermomagnetic.
25. Connect cable from J3 (with Ferrita) to J2 in the Power Supply.
26. Connect tightly the 2 black wires (2 nuts) at the EMI Filter Board.
27. Connect wires of the Thermomagnetic.
28. Connect the GND wire to Chassis.
29. Place the Connectors / Boards Support and secure it to the Chassis byusing the 4 Allen screws.
30. Place the Mylar between capacitors.
31. Screw the 4 black wires and the 3 red wires to the Control Driver Boardand fasten these wires as they were before.
32. Re-install the Thermomagnetic.
33. Place the Lower Cover and screw the white bumpers (4 Allen screws).
34. Re-install the Handswitch and screw the round metal base.
35. Connect GND wire (Allen 7) in the Upper Cover.
36. Connect J5, J6 (Ribbon cable) and J7 at Portable Control Board.
37. Place and screw the Upper Cover (4 Allen screws).
Portable X-ray Units
Service Manual
SM-0510R440
5.2.3 EMI FILTER REPLACEMENT
1. Unscrew Upper Cover (4 Allen screws).
2. Disconnect J5, J6 (Ribbon cable) and J7 at Portable Control Board.
3. Disconnect GND wire (Allen 7) and take out the Upper Cover.
4. Unscrew the round metal base of the Handswitch and take it out.
5. Unscrew the white bumpers of the Lower Cover (4 Allen screws). Takeout carefully the Lower Cover (as line cable still connected) and pass itthrough the connectors window.
6. Place the unit vertically with the Collimator on the Table.
7. Place the end of a flat screwdriver in the opening hole of theMagnetothermic, push and take it out.
8. Take out Mylar between capacitors.
9. Unscrew the 2 Allen screws located at each side of the chassis. Theseare the screws that assemble the Connectors / Boards Support to thePortable Chassis.
10. Disconnect at the EMI Filter Board the 2 black wires from the ControlDriver Board (2 nuts) and the 2 nuts that attache the red cables.
11. Unscrew 2 allen (4) screws that secure the part and pick it up.
12. Install new part and reinstall the unit step by step.
Portable X-ray Units
Service Manual
SM-0510R4 41
5.2.4 INDUCTANCE CHOPPER REPLACEMENT
1. Unscrew Upper Cover (4 Allen screws).
2. Disconnect J5, J6 (Ribbon cable) and J7 at Portable Control Board.
3. Disconnect GND wire (Allen 7) and take out the Upper Cover.
4. Unscrew the round metal base of the Handswitch and take it out.
5. Unscrew the white bumpers of the Lower Cover (4 Allen screws). Takeout carefully the Lower Cover (as line cable still connected) and pass itthrough the connectors window.
6. Place the unit vertically with the Collimator on the Table.
7. Place the end of a flat screwdriver in the opening hole of theMagnetothermic, push and take it out.
8. Cut the plastic fasteners of the black wires connected to the Board.
9. Unscrew the 4 black wires and the 3 red wires the Control Driver Board.
10. Take out Mylar between capacitors.
11. Unscrew the 2 Allen screws located at each side of the chassis. Theseare the screws that assemble the Connectors / Boards Support to thePortable Chassis.
12. Unsolder red cable from the Inductance Chopper and disconnect blackand red cable from Control Driver Board.
13. Unscrew 4 nuts that secure the part and pick it up.
14. Install new part and reinstall the unit step by step.
5.2.5 RECTIFIER BRIDGE REPLACEMENT
1. Unscrew Upper Cover (4 Allen screws).
2. Disconnect J5, J6 (Ribbon cable) and J7 at Portable Control Board.
3. Disconnect GND wire (Allen 7) and take out the Upper Cover.
4. Unscrew the round metal base of the Handswitch and take it out.
5. Unscrew the white bumpers of the Lower Cover (4 Allen screws). Takeout carefully the Lower Cover (as line cable still connected) and pass itthrough the connectors window.
6. Place the unit vertically with the Collimator on the Table.
Portable X-ray Units
Service Manual
SM-0510R442
7. Place the end of a flat screwdriver in the opening hole of theMagnetothermic, push and take it out.
8. Unscrew 2 screws (Allen 2.5) located at each side of the “U” shapedchassis.
9. Disconnect J2 at Power Supply.
10. Release 2 cables that connect the Rectifier Bridge and the EMI Filter.
11. Release the red cable that links the Inductance and the Rectifier Bridge.
12. Unsolder both cables of the Rectifier Bridge.
13. Unscrew nut at the center of Rectifier Bridge and replace the part.
14. Re-install the parts step by step.
5.2.6 POWER SUPPLY REPLACEMENT
1. Unscrew Upper Cover (4 Allen screws).
2. Disconnect J5, J6 (Ribbon cable) and J7 at Portable Control Board.
3. Disconnect GND wire (Allen 7) and take out the Upper Cover.
4. Unscrew the round metal base of the Handswitch and take it out.
5. Unscrew the white bumpers of the Lower Cover (4 Allen screws). Takeout carefully the Lower Cover (as line cable still connected) and pass itthrough the connectors window.
6. Place the unit vertically with the Collimator on the Table.
7. Place the end of a flat screwdriver in the opening hole of theMagnetothermic, push and take it out.
8. Unscrew 2 screws (Allen 2.5) located at each side of the “U” shapedchassis.
9. Unscrew 2 screws located at each side of the chassis.
10. Disconnect J2, J1 and GND cables.
11. Now the Power Supply is ready to be taken out. Unscrew 4 nuts locatedat each corner of the Power Supply.
12. Replace the Power Supply.
13. Re-install the parts step by step.
Portable X-ray Units
Service Manual
SM-0510R4 43
5.2.7 MAGNETOTHERMIC REPLACEMENT
1. Unscrew Upper Cover (4 Allen screws).
2. Disconnect J5, J6 (Ribbon cable) and J7 at Portable Control Board.
3. Disconnect GND wire (Allen 7) and take out the Upper Cover.
4. Place the end of a flat screwdriver in the opening hole of theMagnetothermic, push and take it out.
5. Unscrew cables attached to Magnetothermic and replace the part.
6. Re-install the parts step by step.
5.2.8 UPPER COVER REPLACEMENT
1. Unscrew Upper Cover (4 Allen screws).
2. Disconnect J5, J6 (Ribbon cable) and J7 at Portable Control Board.
3. Disconnect GND wire (Allen 7) and take out the Upper Cover.
4. Disconnect J4 (Ribbon cable) at Portable Control Board.
5. Unscrew the Support (4 nuts) of the Portable Control Board.
6. Take Out the Support.
7. Unscrew nuts of Handswitch Support and take it out.
8. Re-install the Support with the Portable Control Board in the new cover.
9. Re-install the Handswitch Support.
10. Replace Upper Cover.
11. Re-install the parts step by step.
Portable X-ray Units
Service Manual
SM-0510R444
5.2.9 LOWER COVER REPLACEMENT
1. Unscrew the round metal base of the Handswitch and take it out.
2. Unscrew the white bumpers of the Lower Cover (4 Allen screws). Takeout carefully the Lower Cover (as line cable still connected) and pass itthrough the connectors window.
3. Disassemble the Line Plug of the Power Line Cable.
4. Take out cover and install the new Lower Cover.
5. Re-install the parts step by step.
5.2.10 OVERLAY REPLACEMENT
1. Unscrew Upper Cover (4 Allen screws).
2. Disconnect J5, J6 (Ribbon cable) and J7 at Portable Control Board.
3. Disconnect GND wire (Allen 7) and take out the Upper Cover.
4. Disconnect J4 (Ribbon cable) at Portable Control Board.
5. Unscrew the Support (4 nuts) of the Portable Control Board.
6. Take Out the Support and replace the Overlay.
7. Re-install the parts step by step.
5.2.11 HANDSWITCH REPLACEMENT
1. Unthread the round metal base of the Handswitch and take it out.
2. Insert and thread the round metal base of the new Handswitch.
5.2.12 HANDSWITCH SUPPORT REPLACEMENT
1. Unscrew Upper Cover (4 Allen screws).
2. Disconnect J5, J6 (Ribbon cable) and J7 at Portable Control Board.
3. Disconnect GND wire (Allen 7) and take out the Upper Cover.
4. Unscrew nuts of Handswitch Support.
5. Replace Handswitch Support and re-install the parts step by step.
Portable X-ray Units
Service Manual
SM-0510R4 45
5.2.13 POWER LINE CABLE REPLACEMENT
1. Unscrew Upper Cover (4 Allen screws).
2. Disconnect J5, J6 (Ribbon cable) and J7 at Portable Control Board.
3. Disconnect GND wire (Allen 7) and take out the Upper Cover.
4. Place the end of a flat screwdriver in the opening hole of theMagnetothermic, push and take it out.
5. Disconnect the Line wires attached to the Magnetothermic.
6. Disconnect the GND wire of the Line cable (chassis).
7. Cut the plastic cable fastener attached to Line cable and disassembleblack Ferrite block from cable.
8. Loose the external white plastic nut of the Line cable and start taking outit carefully. Remove the wire terminals if necessary.
9. Install new cable. Do not forget to install the ferrites and the plastic cablefasteners.
10. Re-install the parts step by step.
5.2.14 HANDLE REPLACEMENT
1. Remove the special screws at both sides of the Handle. Take care withthe washers.
2. Replace the Handle carefully (do not scratch the covers). The washersmust be installed in the same order that were removed.
3. Tighten strongly the two special screws of the Handle.
Portable X-ray Units
Service Manual
SM-0510R446
5.2.15 HV TANK REPLACEMENT
1. Unscrew Upper Cover (4 Allen screws).
2. Disconnect J5, J6 (Ribbon cable) and J7 at Portable Control Board.
3. Disconnect GND wire (Allen 7) and take out the Upper Cover.
4. Unscrew the round metal base of the Handswitch and take it out.
5. Unscrew the white bumpers of the Lower Cover (4 Allen screws). Takeout carefully the Lower Cover (as line cable still connected) and pass itthrough the connectors window.
6. Remove the Collimator (Refer to Collimator Replacement).
7. Take out Handle (Refer to Handle Replacement).
8. Place the Unit vertically with the Collimator on the Table.
9. Unscrew 2 (Allen 4) screws at both sides of the chassis.
10. Unscrew 2 nuts at the metal support of the Control Driver Board.
11. Remove 2 screws (4x12) in the pins of the HV Tank.
12. Turn the electronic assembly backwards carefully and disconnect J10and the 3 primary contacts attached with nuts. Now the HV Tank isreleased except for the Collimator.
13. Install the Collimator in the new HV Tank and proceed backwards stepby step.
Portable X-ray Units
Service Manual
SM-0510R4 47
5.2.16 COLLIMATOR REPLACEMENT
1. Unscrew Upper Cover (4 Allen screws).
2. Disconnect J5, J6 (Ribbon cable) and J7 at Portable Control Board.
3. Disconnect GND wire (Allen 7) and take out the Upper Cover.
4. Unscrew the round metal base of the Handswitch and take it out.
5. Unscrew the white bumpers of the Lower Cover (4 Allen screws). Takeout carefully the Lower Cover (as line cable still connected) and pass itthrough the connectors window.
6. Disconnect J4 (Collimator / Board cable) at Control Driver Board.
7. Place the Unit vertically with the Collimator on the Table.
8. Loosen four Collimator Safety screws and take out Collimator.
9. Place new Collimator in the Unit. Center the Collimator with the Unit andscrew (6 turns each screw) the four Safety screws at each corner of theCollimator.
THISPROCESSWILLAFFECTCENTERINGOFCOLLIMATORLIGHT. SCREWING MAY MODIFY POSITION OFCOLLIMATOR AND IT MUST BE MANUALLY CENTEREDWHILE TIGHTENING THE SAFETY SCREWS. IT ISRECOMMENDED 6 TURNS TO EACH SCREW, CHECKPARALLELISMBETWEENCOLLIMATORANDUNITCHASSIS(CORRECT POSITION IF NECESSARY) AND FINISHINGTIGHTENING SCREWS.
10. If applicable remove the SIDGuard from the old Collimator and re-installit in the new one.
11. Re-install the parts step by step.
Portable X-ray Units
Service Manual
SM-0510R448
5.3 PARTS REPLACEMENT FOR SPS UNIT
DO NOT MANIPULATE INSIDE THE UNIT WITHOUTDISCONNECTING IT FROM MAINS, RISK OF ELECTRICSHOCK.
POWER MODULE
BASE UNIT
CONNECTOR MODULE
CONTROL MODULE
Refer to Renewal Parts Section for further information on partsidentification.
Note .
Portable X-ray Units
Service Manual
SM-0510R4 49
5.3.1 PORTABLE CONTROL BOARD REPLACEMENT (A3175-01)
1. Unscrew side Cover screws (4) of the Control Module and the Coverscrews (3) of the Connector Module.
2. Take Connector Module Cover off and disconnect Round Connector,Sub--D Connector and GND.
3. In order to release the Power cables attached at the Base, unscrew (4)AllenCover screws locatedat theBaseUnit anddisconnect theGNDandthe Power Line Cables.
4. Raise the Control Module and place it on a table (the Power Line Cableswill pass through the column).
5. Disconnect J4, J5, J6, J7 from Portable Control Board.
6. Unscrew the Support (4 nuts) of the Portable Control Board.
7. Replace the Portable Control Board.
8. Re-install the parts step by step.
5.3.2 EMI FILTER REPLACEMENT
1. Unscrew side Cover screws (4) of the Control Module and the Coverscrews (3) of the Connectors Module.
2. Take Connector Module Cover off and disconnect Round Connector,Sub--D Connector and GND.
3. In order to release the Power cables attached at the Base, unscrew (4)AllenCover screws locatedat theBaseUnit anddisconnect theGNDandthe Power Line Cables.
4. Raise the Control Module and place it on a table (the Power Line Cableswill pass through the column).
5. Remove the 4 cables attached with nuts to the EMI Filter.
6. Remove the 2 screws of the Emi Filter Board support.
7. Replace part and re-install the parts step by step.
Portable X-ray Units
Service Manual
SM-0510R450
5.3.3 INDUCTANCE CHOPPER REPLACEMENT
1. Unscrew side Cover screws (4) of the Control Module and the Coverscrews (3) of the Connectors Module.
2. Take Connector Module Cover off and disconnect Round Connector,Sub--D Connector and GND.
3. In order to release the Power cables attached at the Base, unscrew (4)AllenCover screws locatedat theBaseUnit anddisconnect theGNDandthe Power Line Cables.
4. Raise the Control Module and place it on a table (the Power Line Cableswill pass through the column).
5. Cut heatshrink and unsolder yellow cable from the Inductance Chopper.
6. Cut heatshrink and unsolder black cable from the Rectifier Bridge.
7. Remove the 4 nuts of the Inductance support (one of them with a GNDcable that must be reinstalled at the same nutwhen replacing the part.)
8. Replace part and re-install the parts step by step.
5.3.4 EXTENSORA BOARD REPLACEMENT (A3554--02)
1. Unscrew side Cover screws (4) of the Control Module and the Coverscrews (3) of the Connectors Module.
2. Take Connector Module Cover off and disconnect Round Connector,Sub--D Connector and GND.
3. In order to release the Power cables attached at the Base, unscrew (4)AllenCover screws locatedat theBaseUnit anddisconnect theGNDandthe Power Line Cables.
4. Raise the Control Module and place it on a table (the Power Line Cableswill pass through the column).
5. Unscrew 2 screws at both ends of the Sub--D connector.
6. Disconnect J1 and J2 from the Extensora Board.
7. Remove the 4 screws of the Extensora Board support.
8. Unsolder K1.
9. Replace part and re-install the parts step by step.
Portable X-ray Units
Service Manual
SM-0510R4 51
5.3.5 MAGNETOTHERMIC REPLACEMENT
1. Unscrew side Cover screws (4) of the Control Module and the Coverscrews (3) of the Connectors Module.
2. Take Connector Module Cover off and disconnect Round Connector,Sub-D Connector and GND.
3. In order to release the Power cables attached at the Base, unscrew (4)AllenCover screws locatedat theBaseUnit anddisconnect theGNDandthe Power Line Cables.
4. Raise the Control Module and place it on a table (the Power Line Cableswill pass through the column).
5. Unscrew 4 Allen screws located at the internal area of the ConnectorsModule.
6. Place the end of a flat screwdriver in the opening hole of theMagnetothermic, push and take it out.
7. Disconnect cables from the Magnetothermic and replace the part.
8. Re-install the parts step by step.
5.3.6 POWER SUPPLY REPLACEMENT
1. Unscrew side Cover screws (4) of the Control Module and the Coverscrews (3) of the Connectors Module.
2. Take Connector Module Cover off and disconnect Round Connector,Sub-D Connector and GND.
3. In order to release the Power cables attached at the Base, unscrew 4AllenCover screws locatedat theBaseUnit anddisconnect theGNDandthe Power Line Cables.
4. Raise the Control Module and place it on a table (the Power Line Cableswill pass through the column).
5. Unscrew 2 screws close to the Sub-D connector.
6. Disconnect J1 and J2 and GND from the Power Supply Board.
7. Remove the 4 screws of the Power Supply Board.
8. Replace part and re-install the parts step by step.
Portable X-ray Units
Service Manual
SM-0510R452
5.3.7 RECTIFIER BRIDGE REPLACEMENT
1. Unscrew side Cover screws (4) of the Control Module and the Coverscrews (3) of the Connectors Module.
2. Take Connector Module Cover off and disconnect Round Connector,Sub-D Connector and GND.
3. In order to release the Power cables attached at the Base, unscrew (4)AllenCover screws locatedat theBaseUnit anddisconnect theGNDandthe Power Line Cables.
4. Raise the Control Module and place it on a table (the Power Line Cableswill pass through the column).
5. Remove central nut of the Rectifier Bridge.
6. Apply Heat Conductive Silicone to the base of the Rectifier.
7. Replace the Rectifier Bridge and re-install the parts step by step.
5.3.8 HANDSWITCH REPLACEMENT
1. Unthread the round metal base of the Handswitch and take it out.
2. Insert and thread the round metal base of the new Handswitch.
5.3.9 OVERLAY REPLACEMENT
1. Unscrew side Cover screws (4) of the Control Module and the Coverscrews (3) of the Connectors Module.
2. Take Connector Module Cover off and disconnect Round Connector,Sub-D Connector and GND.
3. In order to release the Power cables attached at the Base, unscrew 4AllenCover screws locatedat theBaseUnit anddisconnect theGNDandthe Power Line Cables.
4. Raise the Control Module and place it on a table (the Power Line Cableswill pass through the column).
5. Disconnect J4 from Portable Control Board.
6. Insert a flat screwdriver or similar in the edge of the overlay and take itoff carefully (it has attached the J4 flat cable).
7. Stick the new Overlay and re-install the parts step by step.
Portable X-ray Units
Service Manual
SM-0510R4 53
5.3.10 POWER LINE CABLE REPLACEMENT
1. Unscrew (4) AllenCover screws located at the BaseUnit and disconnectthe GND and the Power Line Cables.
2. Replace part and re-install the parts step by step.
5.3.11 POWER MODULE WITH COVERS, SIGNAL CABLE AND HV TANK REPLACEMENT
1. Unscrew the Cover screws (3) of the Connectors Module, takeConnector Module Cover off and disconnect Round Connector, Sub-DConnector and GND.
2. Fully extend the Arm.
3. Lay down theTrolley on the floor, with the cassettes basket resting on thefloor, leave the PowerModule face up on a table, chair or similar (this willavoid the arm to push up when removing the Power Module).
4. Unscrew the side screws from the Handle Arm and remove the PowerModule with the Signal cable from the Arm.
5. Re-install the new Power Module with cables at Arm.
6. Place the Unit in stand-up position.
7. Guide cable through the fasteners.
8. Connect Round Connector, Sub--D Connector and GND at ControlModule.
9. Re-install the Cover of the Connectors Module at the Control Module.
5.3.12 UPPER COVER REPLACEMENT
1. Unscrew Upper Cover (4 Allen screws) and take it off.
2. Install new Cover.
3. Unscrew Lower Cover (4 Allen screws).
Portable X-ray Units
Service Manual
SM-0510R454
5.3.13 LOWER COVER REPLACEMENT
1. Unscrew the Cover screws (3) of the Connectors Module, takeConnector Module Cover off and disconnect Round Connector, Sub-DConnector and GND.
2. Unscrew Upper Cover of the Power Module (4 Allen screws) and take itoff.
3. Remove plastic fastener attached to the HV Tank and to the Collimatorcable.
4. Pass the Lower Cover through the cable and take it off.
5. Re-install new Cover.
5.3.14 SIGNAL CABLE REPLACEMENT
1. Unscrew the Cover screws (3) of the Connectors Module, takeConnector Module Cover off and disconnect Round Connector, Sub-DConnector and GND.
2. Unscrew Upper Cover of the Power Module (4 Allen screws) and take itoff.
3. Remove plastic fastener attached to the HV Tank and to the Collimatorcable.
4. Unscrew Lower Cover of the Power Module (4 Allen screws).
5. Pass the Lower Cover though the cable and take it off.
6. Remove 3 Cover screws located at the back of the Power module.
7. Disconnect GND cable at Control Driver Board.
8. Disconnect connectors atConnectorsmodule and remove them from theplate.
9. Remove cables 18 and 19 (black cables marked on board) from ControlDriver Board.
10. Remove Cable Racord at Cover and take off the cable.
11. Re-install the parts step by step.
Portable X-ray Units
Service Manual
SM-0510R4 55
5.3.15 CASSETTES BASKET REPLACEMENT
1. Unscrew 4 Allen screws and take it off.
2. Replace part.
5.3.16 GAS SPRING REPLACEMENT
1. Fully extend the Arm.
2. Lay down theTrolley on the floor, with the cassettes basket resting on thefloor, leave the Power Module face up resting on a table, chair or similar(this will avoid the arm to push up when removing the Power Module).
3. Remove 2 screws at both ends of the Gas Spring.
4. Replace theGas Spring and carefully place the Unit in stand up position.
5.3.17 LOCK LEVER FOR WHEELS ARM REPLACEMENT
1. Unscrew 4 Allen screws at column and take it off.
2. Replace part.
5.3.18 WHEEL GREENTYRE FUSION REPLACEMENT
1. Fully extend the Arm.
2. Lay down theTrolley on the floor, with the cassettes basket resting on thefloor, leave the PowerModule face up on a table, chair or similar (this willavoid the arm to push up when removing the Power Module).
3. Unscrew nuts at both wheels and replace them.
5.3.19 STEERING WHEEL TENTE REPLACEMENT
1. Fully extend the Arm.
2. Lay down theTrolley on the floor, with the cassettes basket resting on thefloor, leave the PowerModule face up on a table, chair or similar (this willavoid the arm to push up when removing the Power Module).
3. Unscrew 4 nuts at every wheel and replace them.
Portable X-ray Units
Service Manual
SM-0510R456
5.3.20 COLLIMATOR REPLACEMENT
1. Unscrew the Cover screws (3) of the Connectors Module, takeConnector Module Cover off and disconnect Round Connector, Sub-DConnector and GND.
2. Unscrew Upper Cover of the Power Module (4 Allen screws) and take itoff.
3. Remove plastic fastener attached to the HV Tank and to the Collimatorcable.
4. Unscrew Lower Cover of the Power Module (4 Allen screws).
5. Pass the Lower Cover though the cable and take it off.
6. Unscrew Lower cover (4 Allen screws).
7. Disconnect J4 (Collimator / Board cable) at Control Driver Board.
8. Place the Unit vertically with the Collimator on the Table.
9. Loosen four Collimator Safety screws and take out Collimator.
10. Place new Collimator in the Unit. Center the Collimator with the Unit andscrew (6 turns each screw) the four Safety screws at each corner of theCollimator.
THISPROCESSWILLAFFECTCENTERINGOFCOLLIMATORLIGHT. SCREWING MAY MODIFY POSITION OFCOLLIMATOR AND IT MUST BE MANUALLY CENTEREDWHILE TIGHTENING THE SAFETY SCREWS. IT ISRECOMMENDED 6 TURNS TO EACH SCREW, CHECKPARALLELISMBETWEENCOLLIMATORANDUNITCHASSIS(CORRECT POSITION IF NECESSARY) AND FINISHINGTIGHTENING SCREWS.
Portable X-ray Units
Service Manual
SM-0510R4 57
SECTION 6 MAINTENANCE
The purpose of this Periodic Maintenance is to guaranty a continue safeperformance of the Unit, to increase serviceability, to reduce costs (down time,repairs, etc.) and to assure the safety (personal risk).
The following checks and maintenance procedures, at the the suggestedintervals, are the manufacturer’s recommendation for the most effectivePeriodic Maintenance schedule for this Portable Unit.
Service tasks here described must be performed exclusively by servicepersonnel specifically trained on medical X-ray Generators.
The first periodicmaintenance service should be performed six (6)months afterinstallation and the subsequent services every twelve (12) months.
6.1 PERIODIC MAINTENANCE PROCEDURES
Prior to any periodic maintenance procedure, it is recommended to perform atest exposure using the same operating factors and conditions as for a typicalexposure.
6.2 GENERAL CLEANING
NEVERATTEMPTTOCLEANORHANDLEANYPARTOFTHEUNIT WHEN IT IS ON. SWITCH IT OFF AND DISCONNECT ITFROM THE MAINS BEFORE CLEANING OR INSPECTING.
6.2.1 EXTERNAL SURFACES
Clean external Covers and surfaces frequently, particularly if corrodingchemicals are present, with a cloth moistened in warm water with mild soap.Rinse wipe with a cloth moistened in clean water. Do not use cleaners orsolvents of any kind.
Cleanconsole keyboardanddisplayswitha clothdampened inwarmwaterwithmild soap. Rinse wipe with a cloth dampened in clean water.
Also check painted surfaces for scratching and touch up as required.
Portable X-ray Units
Service Manual
SM-0510R458
6.2.2 INTERNAL CLEANING
NEVER ATTEMPT TO CLEAN INTERNALLY THE UNIT. THEUNIT MUST BE ALWAYS KEPT SHUT UNLESS A SPECIFICRENEWAL PART PROCEDURE IS TO BE UNDERTAKEN BYHIGHLY QUALIFIED MAINTENANCE PERSONNEL.
6.3 CABLE CHECKS
Check that all electrical connections are firm and secure and that all cableclamps and strain reliefs are in place. Also check that connectors do not haveexposed wires and check cable sheaths for wear and fraying.
Check that all cables are correctly routed.
6.4 CONTROL PANEL
Verify that the handswitch cable and its connection to the Unit are in goodcondition.
Check correct operation of the push-buttons, displays and indicators byperforming the following test:
1. Turn the Unit ON .
2. Select a radiographic technique and observe:
G Technique parameters are displayed on the console.
G Change technique parameters and observe that changes arecorrectly displayed.
G Select 70 kVp and maximum mAs.
G Press “Prep” and verify that the “Ready” indicator is illuminated.Release “Prep” and observe that the “Ready” indicator is off.
G Make a typical exposure, and verify that radiographic exposuresound signal and the exposure status indicator function correctlyduring an X-ray exposure.
Portable X-ray Units
Service Manual
SM-0510R4 59
SECTION 7 RENEWAL PARTS
7.1 MONOBLOCK PORTABLE X-RAY UNIT
FRU 1 = Replacement Part should be in stock.FRU 2 = No need to have it in stock; easy to get after order.FRU N = All parts exist in the Manufacturer stock.
ITEM DESCRIPTION QTY. FRU REP REFERENCE REMARKS
A0 Monoblock Portable X-Ray Unit 1 N Y A6546--02
A1 Portable Control Board 1 1 Y A3175--02 Located under Control Panel
A2 Control Driver Board 1 1 Y A3189--01
A3 EMI Filter Board 1 1 Y A3191--01
A4 Inductance Chopper 1 2 N A6065--02
A5 Rectifier Bridge 1 2 N 53404011
A6 Power Supply 1 2 N 53418013
A7 Magnetothermic ICP 32A Curve-D 1 2 N 50613104
A8 Upper Cover 1 2 N 7371--04
A9 Lower Cover 1 2 N 7372--04
A10 Overlay 1 1 N 55801323 For VET use: 55801319
A11 Handswitch 1 1 N A3399--01
A12 Power Line Cable 1 2 N A3390--05 (04 USA)
A13 Handle 1 1 N 7379--01
A14 HV Tank and X-Ray Tube 1 2 N A6621--21/22/23for 2.8 kW
A6622--21for 4.0 kW
For VET use:A6616--21/22 for 1.4 kWA6617--21/22 for 2.0 kWA6618--21 for 3.2 kWA6619--21 for 4.0 kW
B0 Collimator 1 N Y 6693--05/07/08
B1 Lamp, 24 V 100 W 1 1 N Refer to Collimator Manual for code
B2 External Cover 1 1 N Refer to Collimator Manual for code
B3 Collimator Window 1 2 N Refer to Collimator Manual for code
B4 Control Knob 1 1 N Refer to Collimator Manual for code
B5 Metric Tape 1 2 N Refer to Collimator Manual for code
B6 SID Guard 1 2 N 10076--02 Optional for Human use
Portable X-ray Units
Service Manual
SM-0510R460
MONOBLOCK PORTABLE X-RAY UNIT
A0
A1
A4
A8
A9
A13A12
A3
A6A14
A10
A2
A11A5
A7
B0
B4
B2
B3
B5
B6
Portable X-ray Units
Service Manual
SM-0510R4 61
7.2 PORTABLE MOBILE COLUMN (OPTIONAL FOR MONOBLOCK UNIT)
FRU 1 = Replacement Part should be in stock.FRU 2 = No need to have it in stock; easy to get after order.FRU N = All parts exist in the Manufacturer stock.
ITEM DESCRIPTION QTY. FRU REP REFERENCE REMARKS
C0 Portable Mobile Column 1 N Y 6545--02
C1 Articulated Arm 1 2 N 7772--01
C2 Handle 1 2 N 7773--01
C3 Cassettes Basket 1 2 N 7761--01
C4 Steering Wheels PJO 75 2 2 N 53810008
C5 Steering Wheels PJO 100 2 2 N 53810009
PORTABLE MOBILE COLUMN
C0
C1
C2
C3
C5C4
Portable X-ray Units
Service Manual
SM-0510R462
7.3 PORTABLE STAND (OPTIONAL FOR MONOBLOCK UNIT)
FRU 1 = Replacement Part should be in stock.FRU 2 = No need to have it in stock; easy to get after order.FRU N = All parts exist in the Manufacturer stock.
ITEM DESCRIPTION QTY. FRU REP REFERENCE REMARKS
D0 Portable Stand 1 N Y 6545--03
D1 Articulated Arm 1 2 N 7772--01
D2 Wheel PVR 160x40e 2 2 N 53810022
D3 Wheel 2475 PJH 050 P30--11 2 2 N 53810023
D4 Turning Lock K4--2359--07 2 2 N 53830305
D5 Positioner Ring ELESA GN 37312 2 2 N 54404020
PORTABLE STAND
D0D1
D2
D3
D5
D4
Portable X-ray Units
Service Manual
SM-0510R4 63
7.4 SPS PORTABLE X-RAY UNIT
FRU 1 = Replacement Part should be in stock.FRU 2 = No need to have it in stock; easy to get after order.FRU N = All parts exist in the Manufacturer stock.
ITEM DESCRIPTION QTY. FRU REP REFERENCE REMARKS
E0 SPS Portable X-Ray Unit 1 N Y A7900--01
F0 Control Module 1 N Y A7901--01
F1 Portable Control Driver Board 1 1 Y A3175--02
F2 EMI Filter Board 1 1 Y A3191--01
F3 Inductance Chopper 1 2 N A6065--02
F4 Extensora Board 1 1 Y A3554--02
F5 Magnetothermic ICP 32A Curve-D 1 2 N 50613104
F6 Power Supply 1 2 N 53418013
F7 Rectifier Bridge 1 2 N 53404011
F8 Handswitch 1 1 N A3399--01
F9 Overlay 1 1 N 55801323 For VET use: 55801319
F10 Power Line Cable 6.5 m 1 2 N A3390--05 For America use : A6725--03
G0 Power Module with Covers,Signal Cable and HV Tank 1 1 Y A6546--06
G1 Upper Cover of Power Module 1 2 N 7371--07
G2 Lower Cover of Power Module 1 2 N 7372--07
G3 Signal Cable 1 2 N A7910-01 Between Control Module and PowerModule
H0 Mobile Unit 1 N Y A7902--01
H1 Cassettes Basket 1 2 N 10006--01
H2 Gas Spring 1 2 N 10010--01
H3 Lock Lever for Wheels Arm 1 2 N 10018--01
H4 Wheel Greentyre Fusion 2 2 N 53810030
H5 Steering Wheel Tente 2 2 N 53810017
I0 Collimator 1 N Y 6693--07 With Laser Light: 6693--08
I1 Lamp, 24 V 100 W 1 1 N Refer to Collimator Manual for code
I2 External Cover 1 1 N Refer to Collimator Manual for code
I3 Collimator Window 1 2 N Refer to Collimator Manual for code
I4 Control Knob 1 1 N Refer to Collimator Manual for code
I5 Metric Tape 1 2 N Refer to Collimator Manual for code
I6 SID Guard 1 2 N 10076-02 Optional for Human use
Portable X-ray Units
Service Manual
SM-0510R464
SPS PORTABLE X-RAY UNIT
E0
G1
F2
F9
I0
F1
F0
F8
G0
F3F4
F5
F6 F7
F10
G2
G3
Portable X-ray Units
Service Manual
SM-0510R4 65
SPS PORTABLE X-RAY UNIT
E0
H1
I0
H3
I4
I6
I5I3
I2
H2
H4
H5
H0
Portable X-ray Units
Service Manual
SM-0510R466
This page intentionally left blank.
Portable X-ray Units
Service Manual
SM-0510R4 67
SECTION 8 SCHEMATICS
SCHEMATIC DESCRIPTION MONOBLOCK SPS UNIT
A6546--01 Monoblock Portable X-ray Unit X
A3175--02 Portable Control Board -- Control Portatil PCB X X
A3189--01 Control Driver Board -- Control Driver PCB X X
A3554--02 Extensora Board -- Extensora PCB X
54302050 SPS Portable X-ray System X
Portable X-ray Units
Service Manual
SM-0510R468
This page intentionally left blank.
A
A
B
B
C
C
D
D
E
E
4 4
3 3
2 2
1 1
Pasar este cable por la sonda CT1 de la tarjeta. Control-DriverPass this cable through the current sensor CT1 in the Control-Driver
Pasar este cable por el transformador T1 de la tarjeta. Cntrol-DriverPass this cable throught transformer T1 in the Control-Driver PCB
* optional
Monoblock Portable X-ray Unit
A6546-011/129/05/01A.Querol
29/05/01A.Diaz
AB
DE
First IssueNew L1
N.de C. 02/060N. de C. 03/103
A.QuerolA.Querol
A.QuerolA.Querol
05/017/01
04/0205/03
ABCDEC N de C 02/027 A.Querol 02/02
REV DESCRIPTION ISSUED BY DATE
DRAWING
REVISED
NAME DATE SHEET / OF
REV
SEDECAL
emc
A 3191-01
AC1I
AC2I
AC1O
AC2OTierra
Collimator
Control_1A 3175-01
J6.1J6.2J6.3J6.4J6.5J6.6J6.7J6.8J6.9
J6.10J6.11J6.12J6.13J6.14J6.15J6.16J6.17J6.18J6.19J6.20J6.21J6.22J6.23J6.24J6.25J6.26
J5.1J5.2J5.3
J3.1J3.2
J7.1J7.2J7.3
J4.1J4.2J4.3J4.4J4.5J4.6J4.7J4.8J4.9J4.10
Tierra
J7.4J7.5
J10.1J10.2
Condor-GLC50B
J1.LJ1.N
J2.1J2.6J2.3J2.5Tierra
J2.4J2.2
Keyboard55801181
J1.1J1.2J1.3J1.4J1.5J1.6J1.7J1.8J1.9
J1.10
Vet-Control-Driver
A3189-01
17
Vneg
K1-COMK1-NO
J3.2J3.3J3.4J3.1
19
15
J5.1
J5.10
J1.3
J1.1J1.2
J1.5J1.6
J4.1
J4.2
J4.3
J2.1J2.2J2.3J2.4J2.5J2.6
J2.7J2.8J2.9J2.10
J2.11J2.12J2.13J2.14J1.15J2.16
J2.17J2.18J2.19
J2.20J2.21J2.22
J2.23J2.24J2.25J2.26
J5.2J5.5J5.6
J5.9
J1.4
H.V.TANK W/O TUBE
TR1-1
TR1-3
J10.21
J10.23J10.9
J10.3J10.15J10.2J10.14
J10.1
J10.11J10.25
J10.13
TR1-2
J10.16
Perno de Tierra
VTA
gnd
-15V
FFino
VCAVCK
gnd
+15V
VTK
FGrueso
GND (yellow/green)
Collimator-rtn (Black)
Frtn
+5VReference
mA
/FILOC
/PRE-CHARGE
Reference
IFIL
FILF/G
prep
mAsUP
+5V
Collimator
IFILDEM
Vcarr
kV
EXP
PREP
FG
/ENFIL
/DESEQ
/PS
Reference /CSDAC
Reference
mAS DW
+15V
CLK
LUZ
FF
kVDEM
XON
KV DW /INVOC
/E-Inverter
Reference
Reference
/FAULT
+5V
DIN
KVUP
HandSW1HandSW2
kVmA
Collimator light (Blue)
RX
TX
Laser-rtn (Grey)+5V-Laser (Red)
CB1
Circuit Breaker
L1
160 uH, 147Ap
J13
Female DB9
594837261
D1
6BPC5006
2
4
1
3
J9
Supply line :220/110V 123
LP1
Collimator
J7HandSW
123
D2Laser diode
Ground Stud
12
C1 470nF/2000V
A
A
B
B
C
C
D
D
E
E
4 4
3 3
2 2
1 1
HANDSW
PRESOST
AA B
B
PPZ
KEYBOARD55801181
CONTROL PORTATIL
A3175-011/210/05/00F. Díaz
27/10/00F. Díaz
G CD
EF
NC 04/080
NC 01/118
NC 01/167
NC 02/020NC 03/201
F. Díaz F. Díaz
F. Díaz
F. DíazF.Díaz
30/04/04
29/06/01
21/09/01
05/02/0224/11/03
ABCDEFG
REV DESCRIPTION ISSUED BY DATE
DRAWING
REVISED
NAME DATE SHEET / OF
REV
SEDECAL
DB0
DB3
DB3
DB2
DB6
DB6DB7
DB3
DB6DB5
DB1
DB5
DB6
DB7
DB2
DB0
DB3
DB3
DB3
DB5
DB2
DB4
DB4
DB0
DB6
DB0
DB4
DB5
DB7
DB1
DB6
DB0
DB1
DB4
DB4DB5
DB1
DB7
DB7
DB2
DB4
DB0
DB1
DB2
DB2
DB5
DB7
DB1
DB0DB1DB2DB3DB4DB5DB6DB7
AD0AD1AD2AD3AD4AD5AD6AD7
AD0AD1AD2AD3AD4AD5AD6AD7
DB0DB1DB2DB3DB4DB5DB6DB7
DB0DB1DB2DB3DB4DB5DB6DB7
A/B
A/B
+5V
+5V
+5V
+5V
+5V
+15V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
+15V
+5V
KV DW
74HC27
1213
12
LUZ
J5
1234
C1010nF
mAs UP
U22PC3H7
FG
R13
820
mAs DW
U2
AD7528KR
1413121110987
61615
4
18
1
220
3
19
17
5
DB0DB1DB2DB3DB4DB5DB6DB7
A/BWRCS
REFA
REFB
AGND
OUTAOUTB
RFBA
RFBB
VDD
DGND
FF
U14C
91011
8PREP
EXP
KV UP
D2
1N4448
C4100nF
C15100nF
TP1
C16 100nF
U8
ADC0844
21
19
3
4
5
6
8
7
17161514131211
18
20
10
9
CSRDWR
CH1
CH2
CH3
CH4
VREF
AGND
DB0/MA0DB1/MA1DB2/MA2DB3/MA3DB4DB5DB6
INTR
VCC
GND
DB7
R271K
J3
12
C12
100nF
U15C
9
108
C2
100nF
U5
P89C51RD2
29
15
14
4
89
1011
4041424344123
3736353433323130
1819202122232425
1312
26
27
75
38
16 17
EA/VP
X1
X2
RESET
INT0INT1
T0T1
P1.0P1.1P1.2P1.3P1.4P1.5P1.6P1.7
P0.0P0.1P0.2P0.3P0.4P0.5P0.6P0.7
P2.0P2.1P2.2P2.3P2.4P2.5P2.6P2.7
RDWR
PSEN
ALE/P
TXDRXD
VCC
VSS GND
D3LM336 5.0V
C13
100nF
S11234
8765
U3
74HCT373
3478
13141718
111
256912151619
20
10
D0D1D2D3D4D5D6D7
OCG
Q0Q1Q2Q3Q4Q5Q6Q7
VCC
GND
U11ST24C16
123
6
7
5
8
4
A0A1A2
SCL
WC
SDAVCC
GND
C1
100nF
R6
2K
R14
2K74
C17100nF
D5LM336 2.5V
TP2
U1
ICM7218AIQI
1211131410657
98
42731
252
2426
1821221720231615
19
28
ID0ID1ID2ID3
ID4(SHUT)ID5(DEC)
ID6(HEXA)ID7(DATA)
MODEWRITE
DPSEGASEGBSEGCSEGDSEGESEGFSEGG
D8D7D6D5D4D3D2D1
V+
GND
R33
10K
U10
74HC138
123
645
15141312111097
16
8
ABC
G1G2AG2B
Y0Y1Y2Y3Y4Y5Y6Y7
VCC
GND
DL1
C4433nF
12345678910
R7
1K
C14100nF
TP3
TP4
U6A
74HC4049
32
TP5
D17 1N4448
TP6
U15B
74HC32
4
56
D18 1N4448
R3410K
U1374HCT244
2468
11131517
119
181614129753
20
10
1A11A21A31A42A12A22A32A4
1G2G
1Y11Y21Y31Y42Y12Y22Y32Y4
VCC
GND
R32
10K
U15A1
23
U974HCT244
2468
11131517
119
181614129753
20
10
1A11A21A31A42A12A22A32A4
1G2G
1Y11Y21Y31Y42Y12Y22Y32Y4
VCC
GND
C19
100nF
AR310K
C4333nF
U7
HM6264
109876543
252421232
20262722
1112131516171819
28
14
A0A1A2A3A4A5A6A7A8A9A10A11A12
CS1CS2WEOE
D0D1D2D3D4D5D6D7
VCC
GND
Y1
20 Mhz
C20 100nF
AR1
2K2
R410K
U12
74HCT373
3478
13141718
111
256912151619
20
10
D0D1D2D3D4D5D6D7
OCG
Q0Q1Q2Q3Q4Q5Q6Q7
VCC
GND
R210K
C18100nF
U4BLMC6482
5
67
84
R1
10K
TP7
R3 10K
U15D12
1311
U4ALMC6482
3
21
AR210K
C9
1uF
R5100K
C7
100nF
D1
1N4448
C8 33pF
C6 33pF
J9
12
C510nF
R9
100
C3 100nF
C11100nF
C221nF
C31 100nF
TP14
TP13
CR1
DF04S
J1
345
6
J2
D6MMSZ10T1
J4
123456789
10
D7
MMSZ10T1
KV
IFIL
VCARR
mA
KVDEM
IFILDEM
FILF/G/LUZ_COL
/XON
/PREP
CLK
INVOCDESEQFILOCFAULTPS
/ENABLE
DISPLAY4
L6
L2
L4
L1
L5
L0
DISPLAY5
L3
DISPLAY3
DISPLAY1
DISPLAY6
DISPLAY2
L7
DISPLAY7
DIN
/CSDAC
RXTX
PRECHARGE
/FIL_EN/EN_BUZ
LASER
A
A
B
B
C
C
D
D
E
E
4 4
3 3
2 2
1 1
READY
EXP
KVp mAs
FF
FG
CONTROL PORTATIL
A3175-012/210/05/00F. Díaz
27/10/00F. Díaz
G CD
EF
NC 04/080
NC 01/118
NC 01/167
NC 02/020NC 03/201
F. Díaz F. Díaz
F. Díaz
F. DíazF.Díaz
30/04/04
29/06/01
21/09/01
05/02/0224/11/03
ABCDEFG
REV DESCRIPTION ISSUED BY DATE
DRAWING
REVISED
NAME DATE SHEET / OF
REV
SEDECAL
L5
L3
L6
L1
L4
L4L5
L1
L4
L5
L2
L3
L6
L6
L0
L6
L6
L0
L5
L4
L1
L4
L2L3
L0
L2
L0
L1
L5
L3
L1
L0
L2
L[0..7]
L2
L3
L0L1L2L3L4L5L6L7
L7
L7
L7
L7
L7
L2
L4
L0
L5
L1
L3
L6L7
L0
L1
L2
L3
+5V +5V
+5V
+15V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
C3310nF
R22 1K
U20B 5
67
84
D10
1N4448
C23
100nF
C3410nF
R21 15K4
C4033nF
D11
1N4448
C3510nF
C3710nF
TP9
U6E1112
U21A
74HC4049
3 2
C30100nF
U6D910
U6C76
R3110K
U6B54
R30
100
U21C
74HC4049
7 6
D41N4148
U18A
TC4426
2 7
63
U18B
TC4426
4 5
R2910K
U6F
74HC4049
1415
R1110K
R2810K
U19ALMC6482
3
21
DL3
HDSP3600
abcdefgD.P.
com
C24
100nF
R1210K
C4110nF
U20ALMC6482
3
21
DL5
HDSP3600
abcdefgD.P.
com
DL7
HDSP3600
abcdefgD.P.
com
R2510K
DL2
HDSP3600
abcdefgD.P.
com
DL4
HDSP3600
abcdefgD.P.
com
DL8
DL6
HDSP3600
abcdefgD.P.
com
J10
12
U21B
74HC4049
5 4
DL10
TP8
TP11
J6
1234567891011121314151617181920212223242526
DL13
R15
100K
DL12
R16
10K
R17
10K
R23 1K
C29
1uF
R18
100K
R24
4K75
Q1MTD3055
C27
1uF
C28
1uF
kV
TP16
TP10
U17
MAX232
1
34
5
2
6
16
11
10
12
9
14
7
13
8
15
C1+
C1-C2+
C2-
V+
V-
Vcc
GND
LS1
mA
TP15
R10
3K48
TP12
C26
1uFDL9
C38
100nF
R8
22
C39 100nF
C36 100nF
U16ICM7555
4 8
1 5
3
2
67
RST VCC
GND COMP
OUT
TRIG
THDDISCH
R35
80K6
D12
DL11
D13
C32
100nF
R26
10KD14
D15
Q2MTD3055
C21100nF
C42
100uF16V
C25100nF
D16
1N4448
R19 1K
J7
12345
D8
1N4448
R20 15K4
U19B 5
67
84
D9
1N4448
DISPLAY1
DISPLAY2
DISPLAY5DISPLAY4
DISPLAY6
DISPLAY3
L4
L0
L5
L1
L7
L3
L6
L2
DISPLAY7
INVOC
DESEQ
FILOC
FAULT
PS
FILF/G
CLKDIN
KVDEM
IFILDEM
/PREP
/XON
/ENABLE
RX
TX
PRECHARGE
/LUZ_COL
/CSDAC
/EN_BUZ
mA
KV
VCARR
IFIL
/FIL_EN
LASER
1V= 100V carril
Control-Driver
A 3189-011/7
29/05/03A.Querol29/05/03A.Diaz
GHIJ
KL
N de C 02/060N. de C. 02/136
N.de.C 02/198N.de.C.03/028N.de.C.03/086
N.de.C.03/106
A.QuerolA.QuerolA.Querol
A.QuerolA.Querol
04/0208/0212/0202/0305/0305/03
EFGHIJLA.Querol K
REV DESCRIPTION ISSUED BY DATE
DRAWING
REVISED
NAME DATE SHEET / OF
REV
SEDECAL
CLK
PREP
DIN
V+
V-
/OVERV
IV
REF10
REF10
REF10
REF10
Vcarr
XON
IP
/CSDAC
+15V
+15V
0v
0v0v
0v
0v
0v
0v0v
0v
+15V
+15V
0v
0v
0v
0v
0v
+5V
0v
0v
0v
0v
0v
+5V
AB
JU2
R471K
C40
33nF/25V
U2
TPS5904
1
2
4
3
6
7
R227150
R63
10k
U5A
LF444
3
21
R62
10k
U4A
LF4443
21
R45
2K21
U4D
LF444
12
1314
R64
10k
Q82N7000
C412.2uF
R65
10k
U4C
LF44410
98
R46
1K87
U3C
LF444
10
98
R716k04
C1021nF
R9320k
R782k49
R17510k
R921k
R79
10k
R77 4.02k
R73
20k
D42FDLL261
12
3
U9A
LM339
7
61
R69
20k
R196100
R61
10k
R74
10kR17610k
R140100K
D1
LED verde
D33
1N4448
R844.02k
D28
TL431
61
8
R57
2k49
D43FDLL261
12
3
R56
2k49
D44FDLL261
12
3R51
7k5
D29FDLL261
12
3
U4B
LF444
5
67
U3B
LF444
5
67
TP2
U13D
LF444
12
1314
D30
TL431
61
8
R1391K
R68
10k
R13715k
R131
10k
R19522.1
R66
100
R13810k
U5C
LF444
10
98
R82
133K
R20422.1
R60
133K
AB
JU1
U18
MAX550A
7
2
18
5
4
6
3
REF
OUT
GN
DV
DD
SCLK
DIN
LDAC
CS
+ C647uF
C6810nF
C98100nF
R4
12K-5W
C62
10nF
R72
100
R19722.1
R58
100k
R312K-5W
C4510uF
R54100K
R70
10k
TP10
R50100K
U5B
LF444
5
67
R86
10K
U14A
4584
1 2
R85
10K
Q162N7000
R59100K
R91
10K
R1321k
R90
10K
R80 475
R21610K
R81
133K
U14B
4584
3 4
C540.1uF
R83
133K
R55
133K
D21
TL431
61
8
R49
1K5
C115(R76)10nF
R67
133K
R75
100
R4410K
R4351.1K
C114(R198)10nF
2000:1
Ilim=186A
1V=18.79A
See sheet 3/7
Control-Driver
A 3189-012/7
29/05/03A.Querol29/05/03A.Diaz
GHIJ
KL
N de C 02/060N. de C. 02/136
N.de.C 02/198N.de.C.03/028N.de.C.03/086
N.de.C.03/106
A.QuerolA.QuerolA.Querol
A.QuerolA.Querol
04/0208/0212/0202/0305/0305/03
EFGHIJLA.Querol K
REV DESCRIPTION ISSUED BY DATE
DRAWING
REVISED
NAME DATE SHEET / OF
REV
SEDECAL
DriverA
GATE
EMITERIN
OSC
/OSC
V-
IV
IP
REF10
/OVERV
PREP
/FAULT
/OSC
OSC
A.G
A.EI2-
I2+
V-
+15V
+15V
+15V
+15V
+15V
-15V
-15V
0v
0v
0v
0v
0v
+15V
0v
+5V DR
0v
+15V
0v
U28F
74HC4049
14 15
18
U20C9
810
R217
10K
R130
100
U20B
HEF4081
6
54
D50FDLL261
12
3
C570.1uF
+
-
U12
LM311
2
37
5 641
8
R186
10K
R219
1K
R187
10K
R173
100
R11510K
R166
475K
R161
100
R162
100U15A
MC14013
5
3
1
2
64
D
CLK
Q
Q
SR
+
-
U11
LM311
2
37
5 641
8
D27
1N4448R174
100
R167
475K
R52
1K
R48
20
CT1
D26
1N4448
R53
4K32
R141
1K
C510.1uF
U3D
LF444
12
1314
C4310nF
C39100nF
U9B
LM339
5
42
U20A1
23
TP1
R117475K
R116
1K
Control-Driver
A 3189-013/7
29/05/03A.Querol29/05/03A.Diaz
GHIJ
KL
N de C 02/060N. de C. 02/136
N.de.C 02/198N.de.C.03/028N.de.C.03/086
N.de.C.03/106
A.QuerolA.QuerolA.Querol
A.QuerolA.Querol
04/0208/0212/0202/0305/0305/03
EFGHIJLA.Querol K
REV DESCRIPTION ISSUED BY DATE
DRAWING
REVISED
NAME DATE SHEET / OF
REV
SEDECAL
+5V DR
0VA
-5VA
0VA
+15VA
0VA
0VA
+15VA
0v
0v
+15VA
C321uF
R29
2.21
R31100
C35
0.1uF
R20 2.21
U24
LT1158
1
2
3
7
4
5
8
6
9
10
11
12
13
14
16
15BO
OS
T D
R
V+
BIAS
GN
D
ENABLE
FAULT
BGFB
INPUT
BGDR
V+
SENSE-
SENSE+
TS
TGFB
BO
OS
T
TGDR
D19
BAT49
D20
BAT49
U27
TC4421
2 7
R212.21
C33
0.1uF
+ C1647uF
R18 2.21
D18
BAT49
C360.1uF
C340.1uF Q7
2N70002
13
C31
0.1uF
R321k
D16
1N4448
+ C11100uF
+ C12330uF
R2220
L147uH
+C13
10uF
U25LM7812C/TO220
1 3
2
IN OUT
GN
D
R162.21
D17
BAT49
R33348
R2510K
U29
MAX764
1
2
4
3
7 65
8
OUT
FB
REF
SHDN
V+
V+
GN
D
LX
R24820
R272K7
R282K
+C1533uF
+ C14
68uF
R30
2.21
U30
MC34161
1
2
4
3
7 6
5
8
VREF
IN1
GN
D
IN2
MS OUT1
OUT2
VC
C
U26
TC4421
2 7
R34 348
R35 348
D15
BAT49
D14
BAT49
VCCNC
NC
U31
HCPL061N
1
2
3
4 5
6
7
8
R1510K
R2320
+
C1710uF
Q2
IRLIZ44N
2
1
3
R17
2.21R19 2.21
Q1
IRLIZ44N
2
1
3
R26680K
C28
0.1uF
C26
0.1uF
T2
5
43
62
1
7
C3010nF
GATE
EMITER
IN
OSC
/OSC
V-
1V=10 mA
1V=10 kV
Ilim= 9.5 Apico Filamento.
Ilim=11.6 Apico Colimador
1Vpico en TP11=2.37Apico filamento.1Vpico en TP11=2.9Apico colimador
Control-Driver
A 3189-014/7
29/05/03A.Querol29/05/03A.Diaz
GHIJ
KL
N de C 02/060N. de C. 02/136
N.de.C 02/198N.de.C.03/028N.de.C.03/086
N.de.C.03/106
A.QuerolA.QuerolA.Querol
A.QuerolA.Querol
04/0208/0212/0202/0305/0305/03
EFGHIJLA.Querol K
REV DESCRIPTION ISSUED BY DATE
DRAWING
REVISED
NAME DATE SHEET / OF
REV
SEDECAL
REF10
REF10
VTK
VCKVTA
VTK
VTA
VCA
VCK
CSF1
CSF2
kV-1
/DESEQ
kV
mA
/FILOC
GNDGND
IFIL
GND
VCA
+15V
+15V
+15V
-15V
0v
0v
0v
0v
0v
0v
0v
0v
0v
0v
0v
+15V
+15V
+15V
0v
0v
0v
0v
0v
0v
0v
0v
0v
+15V
+15V
+15V
+15V
+15V
0v
-15V
-15V
-15V
0v
0v
-15V
C67
10nF
C73100pF
D91N4448
U7D
LF444
12
1314
TP11
D121N4448
U7A
LF444
3
21
TP12
D101N4448
TP3
D111N4448
K4
NO
C72
10nF
TP7
R157158
R143
49.9kC7010nF
U7B
LF444
5
67
R13410K
R128
32.4k
U6D
LF444
12
1314
R127
1K
R129
32.4k R108
6.98k
R37
105
R1074k64
R111
4.99K
R124
475
C590.1uF
D35FDLL261
12
3
R135
330K
R100
1K
C76 10nF
+
-U8A
LM339
7
61
D34FDLL261
12
3
R98
1K
D48FDLL261
12
3
R122
10K
R99
1K
D41FDLL261
12
3
R10610K
D37FDLL261
12
3
U6BLF444
5
67
R891K
R114100k
R9745.3K
C580.1uF
D36FDLL261
12
3
C56
3.3nF
R136
330K
D32FDLL261
12
3
+
- U8BLM339
5
42
R1232k8
R15130K1
D45FDLL261
12
3
R21310K
R11345.3K
TP6
U7C
LF444
10
98
D52
1N4448
TP4
U13B
LF444
5
67
R87475
R126
1K
TP9
R109
200K
TP8
R125
200K
U6A
LF444
3
21
C65100pF
R36121
R110
100k
R112
12.7K
R1568K25
R172
1k
R21510K
R144
86.6k
R155
10K
R95
100k
C613.3nF
R88
100K
C7510nF
R153 10K
D53
1N4448R154 10K
U6CLF444
10
98
R152
49.9k
R145
475
R94
100K
R224
10k
R96100K
R14620k
U13C
LF444
10
98
R165
20K
R14720k
R223
64k9
R160
10K
D40
1N4448
D31FDLL261
12
3
J1.6J1.5J1.2
J1.3J1.1
J1.4
See sheet 3/7
See sheet 3/7
See sheet 3/7
See sheet 3/7
1V=83.3A
Control-Driver
A 3189-015/7
29/05/03A.Querol29/05/03A.Diaz
GHIJ
KL
N de C 02/060N. de C. 02/136
N.de.C 02/198N.de.C.03/028N.de.C.03/086
N.de.C.03/106
A.QuerolA.QuerolA.Querol
A.QuerolA.Querol
04/0208/0212/0202/0305/0305/03
EFGHIJLA.Querol K
REV DESCRIPTION ISSUED BY DATE
DRAWING
REVISED
NAME DATE SHEET / OF
REV
SEDECAL
driverE
GATE
EMITERIN
OSC
/OSC
V-
driverB
GATE
EMITERIN
OSC
/OSC
V-
driverC
GATE
EMITERIN
OSC
/OSC
V-
driverD
GATE
EMITERIN
OSC
/OSC
V-
/FAULT
/FILOC
REF10
DRVFA
/DESEQ
/FAULT
CSP1
CSP2
KVDEM
/ENFIL
IFIL
IFILDEM
kV-1
/E-Inverter
XON
/OSCE.G
E.E
B.GB.E
C.G
D.G
D.E
C.E
OSC
/INVOC
DRVFB
V-
+15V
+15V
+15V
+15V
0v
0v
0v
0v
0v
0v
0v
0v
0v
0v
0v
0v
0v
0v
0v
0v
0v
+5V
0v
+15V
+15V
0v
0v
0v
0v
0v
R201
10K
POT2
200k
C117(R184)10nF
R205
10k
R190
100
C95
10nF
C10510nF
R206100K
C971uF
R11810K
U16
MC34067
1
2
3
4
7
5
8
6
9
10
11
12
13
14
16
15
OSC CH
OSC RC
OSC CC
GN
D
IN-
VREF
IN+
EAO
EN
FAULT
SS
OUTB
POW GND
OUTA
O-S RC
VCC
U19
MC34067
1
2
3
4
7
5
8
6
9
10
11
12
13
14
16
15
OSC CH
OSC RC
OSC CC
GN
D
IN-
VREF
IN+
EAO
EN
FAULT
SS
OUTB
POW GND
OUTA
O-S RC
VCC
C1001nF
R17910K
R18943.2K
+
-
U9C
LM339
9
814
R177 10K
R149
100
R2071k
R191
56kR192
10k
R159
42.2K
R121
9.09k
R19310k
R1828.06k
C6910nF
R15010K
R15810K
R18810K
R181
100k
R1031K
R183
150K
R102
4K02
C91no montar
R185100
U13A
LF444
3
21
C74220pF
R21210K
C87470pF
C921.5nF
Q152N7000
2
13
C940.1uF
Q10
2N7000
2
13
U21D
HEF4081
12
1311
Q122N4401
D46FDLL261
12
3
U21C
9
810
Q11
2N4401
D38
1N4448
U21A
1
23
Q132N4401
U20D
12
1311
R1803.01K
R104
332
U21B
6
54
+
-
U9D
LM339
11
1013
C96
33nF
R226(C81)0
R119
100K
R199
100
R133
10K
R5
1.2-0.5W
Q142N7000
Q92N7000
D22BAT49
POT1200k
D24BAT49
D25BAT49
U28C74HC4049
7 6
D23BAT49
R19410K
C901nF
U28B74HC4049
5 4
R21110K
R178
10K
C821nF
TP13
R1012K
TP5
TP14
C520.1uF
R120
332K
U17A
LMC6482
3
2
84
1
+
-
V+
V-
OUT
R105
1K
R1421K
C46
10nF
C831uF
U28E74HC4049
11 12
R20210K
C116(R148)
10nF
R22510k
R20010K
U28D74HC4049
9 10
R20310k
C1131.5nF
C101220pF
C104
470pF
C53
100pF
R171
100
C99680pF
C93100pF
C10347nF
4x680uF-450V
Np=5 vueltas1:20
1:100
60:10
Control-Driver
A 3189-016/7
29/05/03A.Querol29/05/03A.Diaz
GHIJ
KL
N de C 02/060N. de C. 02/136
N.de.C 02/198N.de.C.03/028N.de.C.03/086
N.de.C.03/106
A.QuerolA.QuerolA.Querol
A.QuerolA.Querol
04/0208/0212/0202/0305/0305/03
EFGHIJLA.Querol K
REV DESCRIPTION ISSUED BY DATE
DRAWING
REVISED
NAME DATE SHEET / OF
REV
SEDECAL
/PS
Luz-colimador
Colimador-rtn
+5v
/INVOC
FILf/g
+15V
mA
XON
/FILOC
+5V
IFIL
KV
GND
CLK
Vcarr
DIN
PREP
/ENFIL
GND
/FAULT
Colimador
/E-Inverter
/CSDAC/DESEQ
I2+
I2-
Luz-Colimador
Tierra
Colimador-rtn
FGrueso
Frtn
FFino
FGrueso
Frtn
CSP1
CSP2
V-
V+
CSF1
FILf/g
CSF2
E.G
D.G
D.E
A.G
C.G
C.E
B.E
B.G
E.E
Colimador
/PS
DRVFB
DRVFA
A.E
Tierra
/PRE-CHARGE
/PRE-CHARGE
PREP
FFino
IFILDEM
kVDEM
+15V
+5V
0v0v
+15V
+15V
+15V
+15V
-15V
0v
0v0v
0v
0v
+15V
0v
+5V DR
0v
-15V+15V +5V
0v
0v
+15V
0v
0v
0v
0v
+15V
0v
R1641k
D51
1N4448
R1689.09K
L2666uH
510
R221
130
R1701k
K2PRME 15002 1
212
Q17
2N70002
13
R1
22/5W
C2410nF-1000V
K1.1
R2141k
C119(R39)
10nF
R222
1K
R42
100
U1
BSM200GD60DLC1 2 3 4 5 6 7 8 9 10 11 12
14
13
151719
21
20
1 2 3 4 5 6 7 8 9 10 11 12
14
13
151719
21
20
R6470K-2W
R12
182
Q3STP3NB60FP
2
1
3
R7470K-2W
T3
109-B
54
31
68
U22ICM75554 8
1 5
3
2
6
7
RS
T
VC
C
GN
D
CO
MP
OUT
TRIG
THD
DISCH
R41
100
K4SRC-LX2-00-D-00
116 116
Q6
2N70002
13
R1139
+C9
470uF
D131N4448
R1039
R38182
C222.2nF-1600V
D39FDLL261
12
3
C232.2nF-1600V
R810K
T1
R910K
Q18MTD30552
13
TI-1
K2
NO
D491N4448
C800.1uF
+
C10
100uF
D215V
D515V
D315V
D415V
C25
0.1uF
+C2
+C3
R2
22/5W
D71N4448
+C4
R13100
D61N4448
K1NAIS JM 1aN TMP DC12
12
12
C118(R209)10nF
C1120.1uF K3
SRC-LX2-00-D-001 16116
C120(R14)10nF
R218100K
Q4
STP3NB60FP
2
1
3
R220
10K
R210100
C110
100pF
R40100
K3
R16310k
R169
10k2
D81N4448
+C8
470uF
C10910nF
K4
Q52N7000
2
13
+C1
U10
MC34161
1
2
4
3
7 6
5
8
VREF
IN1
GN
D
IN2
MS OUT1
OUT2
VC
C
C1110.1uF
T4
Trafo colimador
U23A
14027
6
3
5
1
2
74
J
CLK
K
Q
Q
SR
D47
1N4448
R20840.2
J3.2J3.3
J3.1
1517
Vneg
K1-COM
J4.1
J4.3J4.2
K1-NO
J2.25
J2.14
J2.21
J2.3
J2.16
J2.5
J2.18
J2.7
J2.20
J2.9
J2.22
J2.11
J2.24
J2.13
J2.2
J2.15
J2.4
J2.26
J2.17
J2.6
J2.19
J2.8
J2.10
J2.23
J2.12
J2.1
19
J3.4
J5.1
J5.5
J5.2
J5.10
J5.6
J5.9
OSC
/OSC
A
A
B
B
C
C
D
D
E
E
4 4
3 3
2 2
1 1
Control-Driver
A 3189-017/7
29/05/03A.Querol29/05/03A.Diaz
GHIJ
KL
N de C 02/060N. de C. 02/136
N.de.C 02/198N.de.C.03/028N.de.C.03/086
N.de.C.03/106
A.QuerolA.QuerolA.Querol
A.QuerolA.Querol
04/0208/0212/0202/0305/0305/03
EFGHIJLA.Querol K
REV DESCRIPTION ISSUED BY DATE
DRAWING
REVISED
NAME DATE SHEET / OF
REV
SEDECAL
U3.4
U3.11
U6.11 U13.11
U14.7
U9.3
U9.12 U20.7
U20.14
U15.7
U15.14 U8.3
U8.12
U23.16
U23.8
U27.1
U27.4
U27.8
U27.5
U26.1
U26.4
U26.8
U26.5 U21.7
U21.14
U7.4
U12.4
U12.8 U11.8
U5.11
U5.4U4.4
U4.11
U14.14
U24.10
U30.4
U30.8
U24.7
U11.4
U13.4
U7.11
U6.4
0v
+15V
+15V
+15V+15V
-15V
-15V
-5VA
+15VA
-15V
0v0v
0v
C48
+ C1910uF
C7910nF
+ C2110uF
C64
10nF
C50
10nF
C10610nF
C8910nF
C7810nF
C8510nF
C4210nF
C55
10nF
C60
10nF
C77
10nF
C37
10nF
C4410nF
C2910nF
C27
10nF
C38
10nF
+ C2010uF
C84
10nF
+ C1810uFC108
10nF
C71
10nF
C10710nF
C8610nF
C49
10nF
C66
10nF
C63
10nF+ C5
10uF
C47
10nF
+ C710uF
C8810nF
A
A
B
B
C
C
D
D
E
E
4 4
3 3
2 2
1 1
U1
20
74HC244
101 19
PCB EXTENSORA
A3554-021/119/12/02A.Querol
19/12/02A.Díaz
b.1b.2
First Issue
AR1
A.QuerolA.Querol
12/0206/03
b1b.2
REV DESCRIPTION ISSUED BY DATE
DRAWING
REVISED
NAME DATE SHEET / OF
REV
SEDECAL
+5V
+15V
0v
+5V
0v
+15V
+5V
J1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
U1A 74HC2442 18
U1A 74HC244
11 9
R5
22/5W
RP110K
R110K
K1.1
J3
CONNECTOR DB37
1937183617351634153314321331123011291028
927
826
725
624
523
422
321
220
1
U1A 74HC244
8 12
Q1IRLIZ44N1
23
C1100nF
TP2
R6
22/5WK1
NAIS JM 1aN TMP DC12
12
12
TP1
J2
1 2 3 4
U1A 74HC244
6 14
C210nF
TP3
U1A 74HC244
15 5
R3100
R210K
U1A74HC244
4 16
D1
1N4448
R440.2
K1-NOK1-COM
Pasar este cable por la sonda CT1 de la tarjeta. Control-DriverPass this cable through the current sensor CT1 in theControl-Driver
Pasar este cable por el transformador T1 de la tarjeta. Cntrol-DriverPass this cable throught transformer T1 in the Control-Driver PCB
MangueraA7904-01
Mangera A7903-01
Portable X-Ray System
543020501/119/12/02A.Querol
19/12/02A.Diaz
b.1
First Issue
A.Querol
12/02
b.1 b.2
b.2 A.Querol+15V +5V 28/07
6/11+5,en J13 A.Querolb.3
b.3
REV DESCRIPTION ISSUED BY DATE
DRAWING
REVISED
NAME DATE SHEET / OF
REV
SEDECAL
Keyboard55801181
J1.1J1.2J1.3J1.4J1.5
J1.6J1.7J1.8J1.9J1.10
PCB EXTENSORAA3554-02
J1.1J1.2J1.3J1.4J1.5J1.6J1.7J1.8J1.9J1.10J1.11J1.12J1.13J1.14J1.15J1.16J1.17J1.18J1.19J1.20J1.21J1.22J1.23J1.24J1.25J1.26
J3.19J3.37J3.18J3.36J3.17
J3.35J3.16J3.34J3.15J3.33J3.14J3.32
J3.13J3.31
J3.12J3.30J3.11J3.29J3.10
J3.28J3.9
J3.27J3.8
J3.26J3.7
J3.25
J2.1
J2.2
J2.3
J2.4
K1-
CO
MK
1-N
O
J3.5J3.23
J3.4J3.22J3.3J3.21J3.2
J3.20J3.1
J3.6J3.24
Condor-GLC50B
J1.LJ1.N
J2.1J2.6J2.3
J2.5Tierra
J2.4J2.2
Vet-Control-Driver
A3189-01
17
Vneg
K1-COMK1-NO
J3.2J3.3J3.4
J3.1
19
15
J5.1
J5.10
J1.3
J1.1J1.2
J1.5J1.6
J4.1
J4.2
J4.3
J2.1J2.2J2.3J2.4J2.5
J2.6J2.7J2.8J2.9J2.10J2.11J2.12
J2.13J2.14J1.15J2.16
J2.17J2.18J2.19
J2.20J2.21J2.22
J2.23J2.24J2.25J2.26
J5.2J5.5J5.6J5.9
J1.4
H.V.TANK W/O TUBE
TR1-1
TR1-3
J10.21
J10.23J10.9
J10.3J10.15J10.2
J10.14J10.1
J10.11J10.25J10.13
TR1-2
J10.16
Perno de Tierra
ControlA 3175-01
J6.1J6.2J6.3J6.4J6.5
J6.6J6.7J6.8
J6.9J6.10
J6.11J6.12
J6.13J6.14J6.15J6.16J6.17J6.18J6.19J6.20
J6.21J6.22J6.23J6.24
J6.25J6.26
J5.1J5.2
J5.3
J3.1J3.2
J7.1J7.2J7.3
J4.1J4.2
J4.3J4.4
J4.5J4.6J4.7J4.8J4.9
J4.10
Tierra
J7.4J7.5
emc
A 3191-01
AC1I
AC2I
AC1O
AC2OTierra
KVUP
gnd
Reference
Frtn
GND
FGrueso
FF
EXPprep
VTA
KV DW
mA
VCA
Collimator-rtn
LUZ
mAS DW
mAsUP
FFino
VCK
VTK
Collimator light
FG
gnd
-15V+15VReference
Reference
IFILmACollimatorKVDEMKV/ENFILIFILDEM/E-InverterVcarr/CSDAC/DESEQ/FILOC+15V/FAULT/PS/INVOCPREPXONFILF/G+5VReferenceDINCLK/PRE-CHARGE+5VReference
IFILmA
CollimatorKVDEM
KV/ENFILIFILDEM/E-InverterVcarr/CSDAC/DESEQ/FILOC
/FAULT/PS/INVOCPREPXONFILF/G
DINCLK
ac-1
ac-2
+15V-15V+5V
Reference
Reference
TX
RX
-15V
+15V
+5V
IFILmACollimatorKVDEMKV/ENFILIFILDEM/E-InverterVcarr/CSDAC/DESEQ/FILOC
/FAULT/PS/INVOCPREPXONFILF/G
DINCLK
+15V
+5V
ReferenceReference-15V
HandSW2
+5V
HandSW1Reference
kV
+5V
+5V
J5
P2
Sub-D-male
13251224112310229218207196185174163152141
J1
PLUG AC MALE
12
3
J2
123
J6
123
J4
Sub-D-25-Female
1325122411231022
921
820
719
618
517
416
315
214
1
J3
Macho
19371836173516341533143213311230112910289278267256245234223212201
J13
Female DB9
594837261
LP1
Collimator
L1160uH, 147Ap
12
J7HandSW
123
J1
PLUG AC FEMALE
12
3
J9
Supply line :220/110Vac rms
123
J1Sub-D-9- Female
594837261
J3
hembra
1937183617351634153314321331123011291028
927
826
725
624
523
422
321
220
1
Ground Stud
12
CB1Circuit Breaker
D1
6BPC5006
2
4
1
3
J3Sub-D-9- Male
594837261
C1 470nF/2000V