MODEL: RL33EBMS SERVICE SERVICE MANUAL MANUAL Electric Refrigerator CONTENTS PREVENTIVE ACTIONS 2 PRODUCT SPECIFICATIONS 3 ELECTRIC & COOLING PART SPEC. & CRITERION 4 FUNCTIONAL & OPERATIONAL INSTRUCTIONS 5 FUNCTIONS 10 CIRCUIT DETAILS 15 TROUBLE ANALYSIS & REPAIR SOLUTIONS 19 PART BREAKDOWN AND LIST 24 DISASSEMBLY & ASSEMBLY 33 CIRCUIT DISGRAM 39

Upload: duongtu

Post on 08-Mar-2018

258 views

Category:

Documents


14 download

TRANSCRIPT

Page 1: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

MODEL:RL33EBMS

C C

SERVICE SERVICE MANUALMANUAL

Electric Refrigerator CONTENTS

PREVENTIVE ACTIONS 2

PRODUCT SPECIFICATIONS 3

ELECTRIC & COOLING PART SPEC. & CRITERION 4

FUNCTIONAL & OPERATIONAL INSTRUCTIONS 5

FUNCTIONS 10

CIRCUIT DETAILS 15

TROUBLE ANALYSIS & REPAIR SOLUTIONS 19

PART BREAKDOWN AND LIST 24

DISASSEMBLY & ASSEMBLY 33

CIRCUIT DISGRAM 39

Page 2: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

!

1

This represents the materials with regard to the A/C circuit and spare part safety.

Prior to repair, please pull the plug out of the socket from the wall to disconnect the

power to hold the human and wealth harmless.

1-2-1.Direct plug in-and-out is recommended when replacing the relay that attaches to

the compactor lead terminal. When inserting and pulling the plug, relay wobbling

will more likely destroy the compactor terminals or relay.

1-2-2.Restart is not allowed within 5 minutes after power off. Immediate plug in-and-out

will disable the restart.

Do not make any by-pass or circuit change attempt without manufacturer's prior

suggestion.

No prelonged cable or double terminal board is recommended.

For human safety, this procut must be properly earthed. But phone lines and gas

pipes are not recommended for earthing.

!

1. PREVENTIVE ACTIONS

1-1 Safety Precautions

Only qualified technicians who have full command and knowledge of the cooling system and safety inspection are allowed to deliver the maintenance service as specified on the manual.

Please be sure to keep the work place ventilated and safe as this product adopts the combustible and explosive R600a refrigerant.

1-2 Preparations Before Maintenance

This represents the materials included in the appliance maintenance.

Page 3: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

1-3.Warning

1)Liquid Adding Pipe 2)Turn off the valve core 3)Solder the pipe onto the compactor

4) Turn on the valve core tightly

5)Vacuumize and add liquid 6) Onload the pipe nut

1-3-1 Pay attention to the safety during maintenance as R600a refrigerant is

combustible and explosive.

1-3-2 Keep the work place well ventilated without fire source and combustible and

explosive objects arround during the maintenance of R600a refrigerator.

1-3-3 Make sure to lay the R600a clean during CYCLE maintenance (ensure the

system unblocked by inflating nitrogen under HV and LV state.)

1-3-4 Fire soldering is not allowed until the work place is ventilative without R600a

left in the CYCLE.

1-3-5 When no leakage and blocking are found by nitrogen inflation, shut the fire by

the soldering fulid pipe (valve core available at one end) at the process pipe.

1-3-6 Adding the fulid by vacuumizing the liquid pipe and screw on the nut.(no fire,

appliance, MP3, walkman and mobile phone are allowed during operation)

Note: LOCK RING is only used for pipe connection rather than pipe sealing after

adding fluid. If special tools are available for liquid releasing, lead the R600a

via pipes to the designated location.

2

1-4 Special Tools During Maintenance

Page 4: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

1-5 Maintenance Method

3

1.Maintenance Environment

1-1 Pay attention to the safety during maintenance as R600a refrigerant is

combustible and explosive.

1-2 Keep the work place well ventilated without sparks and hot resource around

when repairing the refrigerator's cooling system. Soldering or heating are not

recommended. No smoke also.

1-3 Fire soldering is not allowed until the work place is ventilated without R600a

left in the CYCLE.

2.Refrigerant Remnants Discharging

Prior to reinjecting the refrigerant, conduct the trouble inspection. If the leaking

point is found, eject the remained R600a out.

2-1 Open the compactor back cover, reel out the two process pipes and cut them

by a knife or pilers to discharge the remained R600a refrigerant.(See figure 1)

cutting position

2.2 Leave the refrigerant for a while (about 30 minutes) and connect to the dry

nitrogen to ensure R600a refrigerant is completely discharged and the system

are unblocked. connect to the nitrogen

Gas out

Page 5: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

3-2 Close the process pipe on the dry filter and connect the compactor's special liquid process pipe to a vacuum pump for vacuumizing.

4.Reinjection of Refrigerant

4

3.Vacuumizing

3-1 After all the refrigerants are out, repair the leaking points and replace the driers

and process pipes. The compactor must be fitted with the special liquid process

pipes (see below figure)

Special liquid process pipe

fire soldering

4-1 When the pipe is entirely vacuumized, fill in the R600a refrigerant in the quantity as shown on the brandplate, and weigh by the electric balance. The injection quantity must be exact to the evel of 2g.

4-2 No fire is allowed around when adding liquid. No pocket mobile phone and walkman are allowed during operation.

4-3 Turn on the pipe nut when finishing the liquid adding, and sort the pipes to avoid the abnormal noise.

Page 6: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

5

Temp control type

Temp display type Digital

Functions

Fast refrigeration

Door opening alarm

Standard run

Refrigerating off

Fast freeze

Electronic

1EA

3EA

1EA

2EA

1EA

1EA

1EA/1EA

290

90

200

595

646

1768

76

toughened glass shelf

Spotlight Lamp

Bottle guard

Milk guard

Big bottle guard

Egg guard

dairy guard

Cyclopentane

R600a(60g)

Refrigerating compartment

Bottle guard partition

Egg tray

Freeze compartment

1EA

1EA

Rl33EBMS

2. PRODUCT SPECIFICATION

Model

Volume (ISO)

Total volume

Freeze compartment

Refrigerating compartment

N.V. (L)

Size

Width (mm)

Deepth(mm)

Height(mm)

N.W. (Kg)

Cooling mode Compartment cooling

Control & display

Shelf

Fruit& vege. Tray/partition

Drawer

Ice box

Vesicant

Refrigerant

Three-piece set

Revolving ice box

Page 7: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

6

SPECItem

Model

Power 230V/50Hz

Compressor

Model

Start mode

Oil typeEvaporator

Condenser

Drying filter

Capillary

Molecular sieve XH-9

Finned

Natural convection

RSCR

Sensor

Heater

Freeze

Refrigerating

Defrost

Environmental temp

Defrost

Air heater

Return-air heater

Fuse Defrost

DefrostDefrost time

Hold time

Run capacitor

Refrigerating compartment

Model

ON temp

OFF temp

PTC relayModel

Resistance

Lamp

Freeze compartment

Gear motorFreeze compartment

Door light switch

Fan motor

ID 0.72L2800mm

502AT

502AT

502AT

502AT

240V/15W

3-19 hours (vary with environmental temp.)

4hours 10min (first cycle)

240V 6.5W

HC-050K4 2.5A 250VAC

220~240VAC,50/60HzMN71MNBA6(M2LA49Z)

400VAC/4.5uF

115~125

55~70

B52-120/B

7min 2 min

250V/10A,72 4

15W/220V

7W/220V

280W/220V

JIA XIPERA ZBS1115CY

QP2-12/B

9~17

HC-10

3. SPEC. AND CRITERION OF ELECTRIC & COOLING PARTSC

oo

lin

g c

yc

leE

lec

tric

sp

are

pa

rts

Capacitor

Overload protector

Rl33EBMS

Page 8: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

A B C D E F G H I J K

G

CB

ED

A

F

J

K

H

I

RL33****

7

595 764.5 9 900 42.5 1768 646 1725 43 38.2 1161

4. FUNCTIONAL & OPERATIONAL INSTRUCTIONS

4-1 Product size

Unit:mm

CodeModel

Page 9: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

8

C C

4-2 Part Discription & Disassembly

Pull out the shelf in the arrow direction to disassembly it.

Take out the foods and pull it out in the arrow direction

Ice box Fruit& vege. Tray/salad box Freeze compartment drawer

Page 10: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

condensing pipe

dew proof pipe

liquid barrel

Evaporator

loop pipe

dry filter

Compressordischarge pipe

silver welding rod soldering

silver welding rod soldering

9

4-3Cooling System Cycle Diagram

Page 11: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

10

4-4Circuit Diagram

Π¶ È́ «̧ ÐÆ ÷

Ì ìÀ ¶Ñ ¹Ë õ» ú

1~M

M

S

tC

3 º ìÉ «

º ìÉ «

» ÒÉ «

· Ûº ì

° ×É «

2

1

M

Ì ìÀ ¶Ñ ¹Ë õ» ú

· Ûº ì M

· Ûº ìÌ ìÀ ¶

Ñ ¹Ë õ» ú

Page 12: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

11

fan leaf

fan motor

Evaporator

air out

loop air

loop air

4-5 Cold Air Cycle

Page 13: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

12

A.Freeze Temperature Control1) You may control the freeze temperature by setting the freeze temerature from -15 to -23 at 1 interval.2) Whenever you press the temperature control key, the temperature will display in the following sequence: -18 ,-19 ,-20 ,-21 ,-22 ,-23 ,-15 ,-16 ,-17 ,-18 . 3) The freeze temperature is initialized as -18 .

5. FUNCTIONS

Part

Initializing

Functions

Display the actual temparature. It will display the default temperature when the refrigerating temperature falls into the setting range (+5,-3) and when the freeze temperature falls into the setting range (+3,-3).

When the actual temperature is within the setting range (+5,-3), it will display the default temperature. If the actual temperature exceeds the setting vaule of +3, it will display the setting with flashes. if the actural temperature is less than the setting value of -3, it will display the actual temperature

When the actual temperature is within the setting range (+3,-3), it will display the default temperature. If the actual temperature exceeds the setting vaule of +3, it will display the setting with flashes. If the actual temparature reaches the setting value of -4, it will display the actual temperature -1. if the actural temperature is less than the setting value of -5, it will display the actual temperature -2.

Refrigeraing

Refrigeraing

Freeze

Freeze

General run

Defrost (forecooling+heating+time-delay)

During the defrost forecooling, when the actual temperature is within the setting range (+5,-3), lock the current display till the first stop due to compactor defrosting; During the defrost heating, lock the current display till the first stop due to compactor defrosting;

During the defrost forecooling, when the actual temperature is within the setting range (+3,-3), lock the current display till the first stop due to compactor defrosting; During the defrost heating, lock the current display till the first stop due to compactor defrosting;

If the actual temperature is less than the setting of -3, it will display the actual temperature;

Display FF (Forced Startup)

Display Fd (Forced Defrost)

Fast refrigerationFast freeze

Forced Startup

Forced Defrost

5-2 Constant Temperature Control

5-1 Display

Page 14: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

3) If you select Refrigeration Off, Fast Refrigeration will end up abruptly with a new start of

Refrigeration Off .

4) If you select Fast refrigeration , the air door will be open until the end of fast refrigeration after

1.5 hours or the end by manual. The air door Open and Stop will be determined by the

refrigerating temperature.

13

D.Fast Freeze1) Press the Fast Freeze key to activate the fast freeze light and run the compactor and fan motor.

2) The state will display in the following cycle: fast freeze light on fast freeze light off fast

freeze light on. It will change with the a press of the Fast freeze key.

B.Refrigerating Temperature Control1) You may control the refrigerating temperature from 9 to 1 by pressing refrigerating temerature

key at 1 interval.

2) If pressing the temperature control button, the temperature will display in the following sequence:

5 ,4 ,3 ,2 ,1 ,9 ,8 ,7 ,6 ,5 .

3) The refrigerating temperature is initialized as 5 .

Step

Display

Freeze temp.

Control

st nd rd th th th th th th thPower on 1 press 2 press 3 press 4 press 5 press 6 press 7 press 8 press 9 press 10 press

5 4 3 2 1 8 79 6 5

5 4 3 2 1 8 79 6 5

C.Fast refrigeration1) Press the Fast refrigeration key, the fast refrigeration light is on, leaving the gear air door open.

2) The state will display in the following cycle: fast refrigeration light on fast refrigeration light off

fast refrigeration light on. It will change with a press of the Fast refrigeration key.

st ndStep Power on 1 press 2 press Comments

Display Fast refrigeration light off Fast refrigeration light on Fast refrigeration light off

st ndStep Power on 1 press 2 press Comments

Display fast freeze light off fast freeze light on fast freeze light off

3) If you select Fast Freeze, the compactor and fan will keep running up to 2 hours (start within 10 mins after selection).4) If the temperature meets the defrost condition during the operation of fast freeze, the fast freeze defrost period will be prolonged to the end of fast freeze and the access to the defrost state.

Page 15: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

5-3 Defrost

A.General Function1) Defrost consists of 3 sections: forecooling, heating, time-delay;2) When the following conditions are met, the defrost period is set as 19 hours: the refrigerating compartment door opening and closing opportunity is less than once; the refrigerating temperature is under the setting of +6 and the freeze temperature is under the setting of +4 ; No special functions are selected (Refrigeration Off, Fast refrigeration, Fast Freeze). The defrost period become 6 hours under other conditions except the above. 3) When the appliance is initialized, the first defrost period is 4 hours.4) The compactor and fan will stop during defrosting, the air door will be closed during heating, and the air door will keep running during time-delay.5) Prior to defrosting, the compactor will keep running for 50 mins for forecooling.6) Heating is controlled by the evaporator's sensor. If the sensor breaks down or the evaporator temperature exceeds -5 , heating fails to work and step into the next around.7) The delayed time is 7 minutes.

B.Defrost During Fast Refrigeration1) The defrost operation will be delayed during the fast refrigeration run until the end of the fast freeze.2) If the fast refrigeration function is cancelled by prior manual operation, the defrost function will start up. The compactor running time during the fast freeze will be added to the total work time3) If the Fast Freeze function is selected during the defrost operation, the fast freeze light will be on. But the actual running will not begin until the end of the defrosting.

14

F. Refrigeration Off

1) You may press the function key to select or give up this funciton.2) If you select Refrigeration Off function , the gear air door will be closed and the refrigerating temperature levels with the room temperature.

C.Heater ON/OFF During Defrosting1) Defrost Heater ON Temperature

E.Standard Run

1) You may press the function key to select or give up this funciton.2) If you select the Standard Run function, the freeze and refrigerating temperatures will be controlled at -18 and 5 respectively.

General Defrost Forced Defrost Comments

Lower than -5 Lower than -5 Remains same under all defrosting condition

2)Defrost Heater OFF Temperature

Difference 6 hours 19 hours 4 hours Comments

OFF 12 1212

Page 16: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

15

Test function is to check the product, PCB, process control and maintenance.After the product function determined by selecting the test switch, you must re-electrify the appliance to run the self-diagonisis function.

A.Forced Function1) If you press the Refrigerating Temperature key and the Freeze Temperature key up to 5 minutes at the same time, the compactor will start running with the display board highlighting FF . 2) If the Forced Function is selected, the compactor will start running without 5 minutes' time delay. Defrost operation will stop if the appliance is at the state of defrosting.3) If the forced function is selected, the compactor will keep running for 24 hours. But the refrigerating temperature may be adjusted by pressing the Refrigerating Temperature key.

B.Forced Defrost1) If you press the Refrigerating Temperature key and the Freeze Temperature key up to 5 minutes

simutaneously at forced startup state, the compactor will stop running and step into the forced

defrost state with the display board highlighting Fd .

2) If the evaporator sensor's temperature is higher than -5 under the forced defrost state, the

heater will fail to work and the compactor will resumes after the end of time-delay.

A.Compactor Protective Function1) Restart is not allowed within 5 minutes after the stop of the compactor.

2) For forced startup, the compactor may start working without 5 minutes' time-delay by pressing

the Forced Startup button.

3) When electrifying or switching on the power, this function will start working after 3 minutes'

defrost heating.

4) When opening the refrigerating door, the fan motor will stop running and the air door is closed.

A.Opening Alarm and Illuminator1) Opening of the refrigerating door for 2 minutes will incur Buzzer (Ding).

2) The alarm will stop with light off after 2 minutes

3) If the door is closed, the alerm will stop at once.

5-4 Test Function

C. Test Quitting1) If you press the Refrigerating Temperature key and the Freeze Temperature key up to 5 minutes

at the same time under forced defrost state, the forced defrost function will come to a sudden end.

The refrigerator will reset and Fd disappear.

5-5 Other Controlling Functions

5-6 Opening Alarm and Refrigerating Compartment Illuminating Control

A. Self-diagnosis1) The temperature sensor is considered malfunctional if its temperature go beyond -50 ~ +85 .

If the core chip input voltage exceeds 0.5V~4.5V, it will be deemed as short circuit or open circuit.

5-7 Self-diagnosis

Page 17: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

B.Initializing Self-diagnosis

1) The core chip will self-inspect the temperature sensor within 1 minute after power on.

2) Malfunctional sensors found by the self-diagnosis will be reflected on the display at 0.5S interval.

3) If bad sensors are detected, no press will be admitted. All electric loads will be set to the position

of OFF and the regular temperature control will be retained.

4) If the broken down sensors are repaired, the appliance will be reset to the original state.

16

A.Key Press1) If you press the key under normal work condition , each press will trigger a sound of Ding Dong 2) If you keep pressing the key, only Ding is heard.3) Fault operation will bring about no sound.

B.Door Opening Alarm1) Opening of the regrigerating door for 2 minutes will incur Didi alarm.

C.Forced Function1) Simutaneous press of the Refrigerating Temperature key and the Freeze Temperature button for 5 minutes will trigger Dudu sound at 0.5S interval.

D.Forced Defrost1) Only simutaneous press of the Refrigerating Temperature key and the Freeze Temperature button for 5 minutes under forced defrost state will trigger Dudu sound at 0.5S interval.

5-8 Buzzer

NO

1

2

3

4

5

ITEM

Refrigerating sensor

Main evaporator sensor

Freeze sensor

External sensor

Magnetic switch

DISPLAY TROUBLE

Open circuit

short circuit

Open circuit

short circuit

Open circuit

short circuit

Open circuit

short circuit

COMMENTS

Test temp. lower than -50

Test temp. higher than +85

Test temp. lower than -50

Test temp. higher than +85

Test temp. lower than -50

Test temp. higher than +85

Test temp. lower than -50

Test temp. higher than +85

Magnetic spring switch ON/OFF

is unable to be detected after 1

minute's run

Air door relay failure, or motor, air door magnetic spring switch or magnet trouble

Self-diagnosis Trouble Sheet

C.Self-diagnosis During Normal Operation1) If pressing the Fast Refrigeration key and the Function Selection key for 5 minutes simutaneously

during normal run, the appliance will select the self-diagnosis function with EC shown on the

display.

2) During the Self-diagnosis, key press does not work.

Page 18: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

RESET

D101-104In4007

C105104

C1011000uF

7

5

18

21

C202104

Ic02

5195AI

G

OVcc

C203104

VSS/ASS

17

C801104

C105104

C802104

6. CIRCUIT DETAILS

6-1 Power Supply Part

Power supply

Vcc (DC 5V)

Vcc (DC 12V)

Applied circuit

Chip peripheral circuit and sensor

Control voltage of the display and relay

The AC input voltage will be stepped down by the transformer and be converted into the DC voltage by the rectifying circuit (D101-104). The 1000F/35V wave filter capacitor will be used to filter out the residue AC voltage and the manostat 7812 is used to output the steady 12V DC voltage that will be used as the control voltage of the relay and display. The 12V DC voltage will be regulated by the manostat 7805 to output the steady 5V voltage, which will be used as the output voltage of the chip peripheral circuit and various signals (sensor, switch) .

6-2 Reset Circuit Part

The reset circuit part enables the system program to return the system that meets power trouble

or abrupt power-off to the initial state by the memory of the core chip. At the very beginning of

the power-on, the reset chip voltage is LV, and becomes HV after normal operation.

Page 19: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

Crystal Viberation 4MHz

19 X in

20 Xont

1

3

2

4

5

6

Vcc(5V)

R303 10K -F

R305 10K -F

R403 4.7K

R307 10K-F

CN30WHT

EXT-S/S

R302 1K

R304 1K

R402 10K

R404 10K

R308 1K

C301 104

C302 104

C303 104

C401 104

C402 104

C304 104

26

27

28

29

41

30

18

R303 10K -F

R306 1K

R401 4.7K -F

6-3 Crystal Viberation Part

This circuit is used for the geneation of the resonant clock by receiving and sending the logic element information within the core chip. The time on the clock will play the role of time base. The resonance circuit must apply the rated criteria of each element as specification deviation will change the core chip time and disable the running.

6-4 Sensor Part

Co

re c

hip

Freeze Sensor

Door switch

Magnetic switch

Refrigerating sensor

Main evaporator sensor

The sensor and the resistance in F precision are respectively connected to Earthing and DC5V.

The resistance value that varies with the temperature are converted into the corresponding voltage.

Test the voltage at the A/D transition interface of the core chip to determine the temperature.

Page 20: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

Buzzer

R8014.7K

DC 12V

35

MICOM

19

5 12

1

5

7

9

RY72

RY71

NC

NO

Rc71

RY74

CON71RED

3

6

413

11

14

38

6

5

4

+12V

Ic05

3

1

3

215

116

RY74

1

Rc72

Rc73

6-5 Operation Part

Co

re c

hip

Defrost Heater

Compressor

Fan motor

Inside lamp

Gear motor

If outputing the relevant work circuit signals into the core chip port, the driving chip (ULN2003) will

be activated. The DC 12V voltage will set the relay terminals to the position of On due to relay coils

reaction to activate the circuit.

6-6 Buzzer Part

The driving chip is initiated by the core chip generated CLOCK and impose the 12V volgtage on

the buzzer to make it voice a sound.

Page 21: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

Default

Freeze Temperature Shift (unit: ) Refrigerating Temperature Shift (unit: )

SHIFT

-1.0

-2.0

-3.0

+1.0

+2.0

+3.0

+4.0

-1.0

-2.0

-3.0

+1.0

+2.0

+3.0

+4.0

6

0

0

0

0

1

1

1

1

5

0

0

1

1

0

0

1

1

4

0

1

0

1

0

1

0

1

3

0

0

0

0

1

1

1

1

2

0

0

1

1

0

0

1

1

1

0

1

0

1

0

1

0

1

SHIFT

Default

P03

P00

P01

P02

R601-60310K -J*3

D601

D602

D603 D606

D605

D604 D607

D608

D609

D610

D611

D612

20

P04

P05

P06

6-7 Functions

Core chip

The output signals such as GRID waves after initializing will be received by the diode and function confirmed by the metrix. The #32,#24 and #25 interfaces of the core chip only generate the same GRID waves output at the initializing stage.

Page 22: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

C C

21

7. TROUBLE DIAGNOSIS & REPAIR SOLUTIONS

Mainboard inspection method

At the self-diagnosis stage, you must cut off and reconnect to the power for inspection.The self-diagnosis codes are listed belowself-diagnosis codes:

NO

1

2

3

4

5

ITEM

Refrigerating sensor

Main evaporator sensor

Freeze sensor

External sensor

Magnetic switch

DISPLAY TROUBLE

Open circuit

short circuit

Open circuit

short circuit

Open circuit

short circuit

Open circuit

short circuit

COMMENTS

Test temp. lower than -50

Test temp. higher than +85

Test temp. lower than -50

Test temp. higher than +85

Test temp. lower than -50

Test temp. higher than +85

Test temp. lower than -50

Test temp. higher than +85

Magnetic spring switch ON/OFF

is unable to be detected after 1

minute's run

Air door relay failure, or motor, air door magnetic spring switch or magnet trouble

Door switch

Refrigerating sensor

Refrigerating compartment

Freeze compartment

Sensor resistance and core chip voltage and temp.

Temp TempResistance ResistanceResistance ResistanceVoltage VoltageVoltage VoltageTemp Temp

Page 23: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

1. Prior to trouble settlement, check if the power socket is electrified and the connecting power supply spec. is normal.2. Check if the power botton on display is pressed or not.3. If other troubles are found, please refer to the remarks on the next page to make an inspection.

Primary Inspection

Y

Y

Y

N

22

Y

N

N

N

Start

Is primary voltage of the

transformer ok ?

Is secondary voltage of

Transformer ok ?

Is display ok ?

Power on again

Normal

Check and repair the

wire assembly

replace the transformer

Repair or replace the

display

Replace the mainboard

subassembly

Test the 7812 output woltageTest the 7805 output woltage

Page 24: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

A. When the freeze sensor breaks down

23

7-2 When troubles are found by self-diagnosis

Start

Is the mainboard connector

plug-in ok?

Are the mainboard sensor connectors linked properly?

Is the input voltage on the core chip leg 24# ok?

Is the freeze temperaturesensor ok?

Change the temp.sensor

Plug in the connectoragain for bad contact.

Disconnect sensors

Check for miss or vold welding, short circuit

Are PCB and temp. sensor ok? Recheck the connector

N

N

N

N

Y

Y

Y

Y

Y

Y

Y

Y

B.When the freeze evaporator sensor breaks down

Start

Is the freeze evaporator sensor

Plug-in ok?

Are the connector and freezeevaporator sensor connected?

Is the input voltage on the core chip leg 25# ok?

Is the mainboard plug-in ok?

Plug in the connector again for bad contact.

Change the evaporator sensor

Disconnect the wire between the connector and the evaporator sensor

Check for miss or vold welding, short circuit

Are PCB and defrost sensor ok? Recheck the connector

N

N

N

N

Page 25: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

D.When the air door magnetic spring switch breaks down

24

C. When the refrigerating sensor breaks down

Start

Is the mainboard connector plug-in ok?

Are the main board sensor connectors linked properly?

Is the input voltage on the core chip leg 26# ok?

Is the refrigerating temperature sensor ok?

Change the temp.sensor

Plug in the connector again for bad contact.

Disconnect sensors

Check for miss or vold welding, short circuit

Are PCB and temp. sensor ok? Recheck the connector

N

N

N

N

N

N

N

N

Y

Y

Y

Y

Y

Y

Y

Y

Start

Is the magnetic spring swith ok?

Are the magnetic spring connectors well linked?

Is the input voltage on the core chip leg 27# ok?

Is the magnetic spring switch plug-in ok?

Plug in the connector again for bad contact.

Change the magnetic spring switch

Disconnect the wire between

the magnetic spring switch connectors

Check for miss or vold

welding, short circuitAre PCB and magnetic spring switch ok?check the connector

Page 26: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

E. When the door switch breaks down

25

Start

Is the door switch ok?

Are the door switch connectors well linked?

Is the input voltage on the core chip leg 28# ok?

Is the door switch plug-in ok?

Plug in the connector again for bad contact.

Change the door switch

Disconnect the wire between the door switch connectors

Check for miss or vold

welding, short circuitAre PCB and door switch ok?

Recheck the connector

N

N

N

N

Y

Y

Y

Y

Page 27: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

26

8. PART BREAKDOWN & LIST

8-1 Door

Page 28: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

27

No Part number Description Q'ty Spec Remark

Page 29: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

26

8-2 Freeze Compartment

Page 30: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

29

No Part number Description Q'ty Spec Remark

1-1

1-2

1-3

1-4

6-1

6-2

6-3

6-4

7-1

7-2

7-3

9-1

9-2

9-3

9-4

9-5

9-6

9-7

9-8

9-9

9-10

9-11

9-12

9-13

9-14

9-15

Page 31: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

30

8-3 Refrigerating Compartment

Page 32: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

31

No Part number Description Q'ty Spec Remark

9-1

9-2

12-1

12-2

12-3

Page 33: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

32

C

C

8-4 General Assembly

Page 34: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

33

No Part number Description Q'ty Spec Remark

1-1

1-2

1-3

1-4

1-5

1-6

1-7

18-1

18-2

18-3

18-4

18-5

18-6

18-7

18-8

18-9

Page 35: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

34

No Part number Description Q'ty Spec Remark

Page 36: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

1.Remove the screw from the lampshade and unclench two latches at one-side with a 1-shaped screwdriver to take off the lampshade.

AlertWhen changing the refrigerating compartment lamp, disconnect the power to avoid an electric shock.

2.Turn off the lamp.

3.When the new lamp is fitted, setup the lampshade latches from right to left as well as the screws.

2 1

2 1

35

1. Take out the freeze compartment drawer.

2.Remove the two screws from the air-duct subassembly framework.

Two screws

9. DISASSEMBLE & ASSEMBLY

9-1 Change The Refrigerating Compartment Lamp

9-2 Disassembly of the Freeze Compartment Air-duct Subassembly

Page 37: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

3. Pull out ice box subassembly framework.

5.Hold down the terminal hook and draw out the terminal in the direction of the arrow.

4.Remove the four screws from the air-duct front cover that shall be drawn out in the direction of the arrow.

36

6.Remove the two screws from the air-duct subassembly back cover.

remove the two screws

Page 38: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

7.Take apart the air-duct subassembly in the direction of arrow and take down the plug-ins, such as sensors etc.

Assembly of The Freeze Air-duct Subassembly

Keep 9 (refrigerant and noise down)

Evaporator framework

Evaporator

Main evaporator sensor

Temperature fuse

37

Page 39: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

1.Remove the screws from the compressor cover.

2.The Compressor Assembly

Alert: Prior to repairing the refrigeration system, make sure that no refrigerant remains are found and that the workplace is ventilated.

38

9-3 Assembly of The Compressor and The Terminal Box

Alert: Prior to repairing the refrigeration system, make sure that no refrigerant remains are found and that the workplace is ventilated and safe.

Page 40: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

1.Disconnect the power supply.

Capacitor

3.Terminal box assembly

2.Take off the terminal box cover with a screwdriver.

Relay

D/C transformer

Protector

39

9-4 Terminal Box Assembly

AlertRemove the plug from the power socket when replacing electric elements.

Page 41: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

Repair and replace the electric parts inside the top front cover.

Open the door and remove the screw with a cross-head screwdriver.Unclench the top front cover with a 1-shaped screwdriver.

Set up the top front cover by pressing it into the hook (the sound Kaca will be heard as it reaches the right position).

C

C

2

1

2

1

C

C

3

40

9-5 Top Front Cover Disassembly

Page 42: SERVICE MANUAL -  · PDF fileservice as specified on the manual. ... Compressor Model Start mode Oil type Evaporator Condenser Drying filter ... HC-10 3. SPEC

10. CIRCUIT DIAGRAM

10-1 Luxury Type

Freeze sensor

Evaporator sensor

Refrigerating sensor

Magnetic sw

itchD

oor switch

Lo

ckin

g

Fa

st fre

eze

Freeze tem

perature

Refrigerating temperature

Function selection

Fa

st refrig

era

tion

41