service manual - diagramasde.comdiagramasde.com/diagramas/aires-acondicionados/aph289sef[11].pdf ·...
TRANSCRIPT
APH289SEFAPH289SEG
SERVICE Manual
CONTENTSAIR CONDITIONER
11. Product Specifications
12. Operating Instructions
13. Disassembly and Reassembly
14. Refrigerating Cycle Diagram
15. Troubleshooting
16. Exploded Views and Parts List
17. Block Diagram
18. PCB Diagram
19. Wiring Diagram
10. Schematic Diagram
FLOOR STAND TYPE AIR CONDITIONER
1Samsung Electronics
1. Product Specifications
1-1 Table
APH289SEF/APH289SEGModel
ItemUnit
Indoor
Outdoor
Piping
Indoor
Outdoor
1. Cooling Capacity / Heating Capacity
2. Power Consumption(Cooling / Heating)
3. Current Consumption(Cooling / Heating)
Noise
Evaporator
Blower Motor
Blower
Condenser
Refrigerant Mass
Compressor
Fan Motor
Fan
Service Valve
W x H x D
W x H x D
W x H x D
W x H x D
W x H x D
mm
mm
mm
mm
mm
kg
kg
kg
kg
BTU/h
W
A
dB
dB
Row x Step
Turbo
High
Medium
Low
Row x Step
g
Unit
Packing
Unit
Packing
Packing
Unit
Packing
Unit
Packing
Indoor
Outdoor
Construction
Fin
Capillary Tube
No. of Polarities
Capacitor
RPM
(Cooling/Heating)
Type
Construction
Fin
R22
Maker
Model
Type
No. of Polarities
Capacitor
RPM(Cooling/Heating)
Type
High pressure side
Low pressure side
Indoor Unit
Outdoor Unit
Weight
ElectricCharacteristics
Size
575 x 1,840 x 320
678 x 1,910 x 432
880 x 798 x 310
1,023 x 841 x 413
FPH3858G
48
53
74
77
26,000/30,000
2,600/2,800
12/12.5
48
63
2 x 28
D5 1.5
1.5 x 400(1) 1.5 x 600(2) 1.5 x 1,200(1)
6P
450VAC 4.5uF
570/570
520/520
470/470
425/425
SIROCO
2 x 30
WAVE 1.7
2,000
COPELAND
ZR34K3-PFJ
SCROLL
6P
450VAC 3.0uF
890/890
PROPELLER
3/8''
5/8''
Samsung Electronics2
2. Operating Instructions
2-1 Control System Chart
Operation Mode
Operating Mode
Fan speed Mode
Air FlowDirection Mode
Timer Mode
Manual 4 STEPS
NATURAL
AUTO
Air Flow blade(Right/Left orientation)
Air Flow blade(Right/Left orientation)
Setting On Timer
Setting Off Timer
Automatic Fan Speed control by the difference between set temperature and room temperature.
By Remote Control only, On/Off only
By Remote Control only, On/Off only
By Remote Control only, On Time Setup(30 min ~ 24hr)
By Remote Control only, Off Time Setup(30 min ~ 24hr)
Low, Medium, High, Turbo
Automatic conversion of Fan Speed by Chaos calculation into High, Medium, and Low. Natural is available in Auto mode only.
AUTO Operation
Cooling Operation
Heating Operation
Dry OperationHumidity control by the difference between set temperature androom temperature(18˚C ~ 30˚C)
FAN Operation Operating the room fan motor only(Low, Medium, High)
Room temperature control by the set temperature(18˚C ~ 30˚C)
Room temperature control by the set temperature(18˚C ~ 30˚C)
Automatic control by the difference between set temperature androom temperature
Main Switch Operation
Remote Control Operation
On/Off, Temperature Adjustment, Mode, Turbo, Perfect Air Cleaning
On/Off, Temperature Adjustment, Turbo, Fan Speed, Operating Mode, Digital Flow(Focus, Wide, Long, Stereo), Air Flow(Up/Down), Air Flow(Right/Left), Air Cleaning, Reserved,Health, Perfect Air Cleaning(On/Off, Speed, Anion)
Operating Instructions
3Samsung Electronics
Error Symptom Main body LED display
Gas Sensor Error
Indoor Room Temperature Sensor Error
Auto Shutter Error
Perfect Air Cleaning Fan Motor Error
Communication between Main PCB and Panel PCB Error
Indoor Piping Temperature Sensor(Open/Short)
Outdoor Piping Temperature Sensor(Open/Short)
ConvenientFunctions Mode
Turbo
Save If you set Save at the preset temperature below 25˚C,The preset temperature will change to 26˚C to increase the roomtemperature by degrees.If you set Save at the preset temperature over 26˚C,The preset temperature will go up minutely.To raise dust collecting efficiency, the Air Flow Blade(Up/Down) will start rotating automatically.
Self-diagnosisFunction
Displays an error message on the temperature display window of Panel Display.
Operates the indoor fan motor(Turbo) and compressor for 30 minutes regardless of the set temperature and put down theAir Flow Blades(Up/Down).
Digital Flow Available for Cooling/Heating only.If you select any existing mode, Turbo, Save, or Health mode will be cancelled.Temperature will be set up by Cooling/Heating condition.Fan speed will be set up by Cooling/Heating condition.
Health Starts Perfect Air cleaning and generates anions.
Air Cleaning Mode Perfect Air Cleaning Operates Dust Collector.
Anion Operates Anion Generator.
Perfect CleaningAir Flow Speed
Controls Perfect Cleaning Air Flow Speed.(Low, Medium, High, Turbo)
Samsung Electronics4
� You can operate the air conditioner with the control panel when you can't or don't want to operate the air conditionerwith the remote control.
2-2 Key Types and Functions
2-2-1 Control Panel
2-2-2 Using the Control Panel on the Indoor Unit
� You can operate the air conditioner with the control panel when you can't or don't want to operate the air conditioner with the remote control.
Operatingindicators
Turbo indicator
Digital Flow indicator
Anion indicator
Perfect air cleaningindicator
Timer indicator
Health indicator
Outdoor operatingindicator
Temperature setting
Temperature adjustment buttons
Fan speedLock function
indicator
Air purity levelindicator
Perfect air cleaningbutton
Turbo button
Operating modeSelection button
Remote controlsensor On/Off button
1. To operate the air conditioner, press the (On/Off) button.
1. Result: • The air conditioner starts up in the mode selected when the unit was
last used.
• The indoor unit beeps.
• If you want to stop, press the (On/Off) button once again.
2. Select the operating mode by pressing the button.
1. Note -You can select each AUTO, COOL, DRY, FAN, HEAT mode.
3. To adjust temperature, press the buttons once or more times.
1. Result: • If you finish setting the temperature, the current temperature indicates
on the control panel.
4. To select the Turbo mode, press the button.
5. To select the perfect air cleaning function, press the button.
Operating Instructions
5Samsung Electronics
2-2-3 Other Functions
� Lock function
� 1. Press the buttons simultaneously for 3 seconds.
� 1. Result: • indicates on the control panel.
� 1. Result: • The control panel is locked.
� 1. Result: • Note: You can use the remote control even if the control panel is locked.
� 2. To cancel the lock function press the buttons simultaneously for 3 seconds once again.
� Air purity level display
� 1. If the air conditioner is on, the air purity level is displayed automatically on the control panel.
� 1. Example : Very pure
� 1. Example : Pure
� 1. Example : Impure
� 2. If the air conditioner is off, press the button for 3 seconds once again.
� 2. Result: The air purity level is displayed on the control panel.
� 3. To clear the control panel, press the button for 3 seconds once again.
� Turning off the light
� 1. Press the button for 3 seconds.
� 1. Result: Light of the control panel is turned off.
� 2. To turn on the light again, press the button.
Samsung Electronics6
2-3 Check and Test Operation
2-3-1 Check
� Be sure to check the following again after completion of installation.
1. Check the piping connection area for any gas leakage.
2. Is the drain hose properly connected?
3. Is the insulation of the piping in good condition? 4. Is grounding properly made?
Insulation
Above 30m
Indoor connection area
Outdoor connection area
Operating Instructions
7Samsung Electronics
2-3-2 Test Operation
� After checking, read the owner’s instructions carefully, and perform a test operation. Then deliver the unit to the customer.(When delivering the unit, be sure to read carefully and follow the contents of the owner’s instructions.)
• Be sure to check whether the service valve is opened before attempting to perform the test operation.
• Be sure to perform the test operation after installation. It is easy to start the test operation in winter if you increase the sensor temperature to 23°C ~ 25°C by holding the indoor temperature sensor. (Cooling operation)
• ✳ When the outdoor temperature is below zero, do not test operation for more than 3 minutes. Otherwise, the compressor will be damaged.
Temperature sensor
Samsung Electronics8
3. Disassembly and Reassembly
3-1 Indoor Unit
Stop operation of the air conditioner and remove the power cord before repairing the unit.
No Parts Procedure Remark
1 Indoor Unit 1) Stop the air conditioner and shut off theMain Power.
2) Open the ass'y Inlet and detach theconnection hook.
3) Loosen 2 fixing screws at the bottom of theass'y Panel Display.
4) Detach the connection wire between theMain PCB and the Display.
9Samsung Electronics
Disassembly and Reassembly
No Parts Procedure Remark
5) Detach the other wires connected to theMain PCB.
6) Loosen 3 fixing screws between the ass'y Shutter and the Perfect Cleaner.
7) Loosen 2 fixing screws at the bottom ofthe ass'y Shutter.
8) Lift the ass'y Shutter to detach it.
Samsung Electronics10
Disassembly and Reassembly
No Parts Procedure Remark
9) Loosen 4 fixing screws on both sides ofthe Perfect Cleaner.
10) Lift the Perfect Cleaner to detach it.
11) Detach the ass'y Cover Evaporator-Up.
12)Loosen 2 fixing screws to connect theass'y Panel Drain and the Cabinet.
13)Pull the ass'y Evaporator upward towardyou to detach it.
11Samsung Electronics
Disassembly and Reassembly
No Parts Procedure Remark
14)Detach the Panel Drain.
15)Detach the Holder Pipe.
16)Detach the Cover Bell Mouth.
17)Loosen the Blower nut to detach theBlower.
18)Loosen the ass'y duct and 4 fixing screws.
Samsung Electronics12
Disassembly and Reassembly
No Parts Procedure Remark
2 Shutter
19)Detach the ass'y duct from the Cabinet.
20)Loosen 3 Motor fixing screws and 1 Earth screw.
1) Loosen 1 fixing screw of the cover MainPCB.
2) Detach the Main PCB.
Disassembly and Reassembly
13Samsung Electronics
No Parts Procedure Remark
3) Detach the Cover Evaporator Front.
4) Detach the Cover Outlet-LF/RH.
5) Detach the ass'y Body Outlet.
Disassembly and Reassembly
Samsung Electronics14
No Parts Procedure Remark
6) Detach the Holder Hinge at the bottom ofthe Panel Shutter.
7) Split the Body Outlet to both sides todetach the hinge Shutter low.
8) Loosen the fixing screw connected to thehinge Shutter Up.
Disassembly and Reassembly
15Samsung Electronics
No Parts Procedure Remark
9) Detach the Panel Shutter.
10)Push down the Gear Rack to detach it.
11) Detach 2 Link Blade Hs.
12)Detach the Support Blade H.
Disassembly and Reassembly
Samsung Electronics16
No Parts Procedure Remark
13)Detach 5 Blade Hs and 1 Blade H-Motor.
14)Detach 2 Link Blade Vs.
15)Detach 6 Blade Vs and 2 Blade V-Motors.
16)Detach the wire connected to each Motor.
17)Detach the PCB Photo Sensor.
Disassembly and Reassembly
17Samsung Electronics
No Parts Procedure Remark
18) Detach 2 Motor Blade Vs.
19) Detach the Guard Motor.
20) Detach 1 Motor Blade H.
Disassembly and Reassembly
Samsung Electronics18
No Parts Procedure Remark
3
4
Panel Display
Perfect Cleaner
1) Detach the ass'y Panel Display.
2) Loosen 3 fixing screws connected to theCover Panel PCB in the back.
3) Detach the Cover Panel PCB.
4) Detach the Panel PCB.
1) Detach the Ass'y Perfect Cleaner.
Disassembly and Reassembly
19Samsung Electronics
No Parts Procedure Remark
2) Detach the ass'y Electric Filter.
3) Detach the Cover HVPS DC.
4) Loosen the wire fixing bolt connected tothe Plate HVPS and detach the HighPressure Generator.
5) Detach the fixing screw of the ass'yMagnet on the top left corner.
Disassembly and Reassembly
Samsung Electronics20
No Parts Procedure Remark
6) Detach the Cover Magnet S/W.
7) Detach the Guide Cross Fan Up.
8) Detach the Anion Generator.
9) Detach both the Cross Fan and the Motorfrom the Guide Cross Fan Low.
Disassembly and Reassembly
21Samsung Electronics
No Parts Procedure Remark
5
6
Evaporator
Inlet
1) Loosen 9 fixing screws of the CoverEvaporator LF/RH.
1) Open the Grille Inlet LF/RH and pull out 2 Filter Pres.
2) Detach the Guide Inlet Air.
Samsung Electronics22
3-2 Outdoor Unit
No Parts Procedure Remark
1 Common Work 1) Detach the Cover Top by removing thescrews fixing Cover Top.
2) Detach the Back Cabinet by removing thescrews fixing Back Cabinet.
3) Detach the Control Box by removing thescrews fixing Control Box. (The feature of wiring may vary with themodels.)
4) Detach the Cover Front by removing thescrews fixing Cover Front. (M6 SCREW)
23Samsung Electronics
HeatExchanger
(Evaporator)
Gas side
3-Way valve
3-Way valve
Liquid side
Cooling
Gas leak check point
HeatExchanger
(Condenser)
Heating
Capillary tube
Check valve
Compressor
4-Way valve
Capillary tube
� Refrigerating cycle temperature and pressure
• Amount of refilling per extension length of 1m;• When extending the pipe length by more than 5m, 40g of R22 refrigerant should be refilled per extension length of 1m.
Allowable pipe length : Maximum 15m
Allowable pipe drop distance : Maximum 10m
Operating ConditionSTD Pressure
(kg/cm2G)(GAS SIDE)
Piping Temp. Use Temp. Condition (°C)
T1 T2Indoor Outdoor
DB
4.5~5.5
6.5~7.5
3~4
18.5~20.5
-
-
40~45
50~55
30~35
32~36
36~40
28~32
9~12
14~18
1~4
65~75
70~80
40~45
27
32
21
20
27
20
19
23
16
-
-
-
35
43
21
7
21
2
24
26
16
6
16
1
Cooling
Heating
Standard
Max over load
Low temp.
Standard
Max over load
Deice
WB WBDB
INDOOR UNIT OUTDOOR UNIT
4. Refrigerating Block Diagram
Samsung Electronics24
Troubleshooting procedures
1 • Check the items to check first time.
2 • Check the self-diagnostic mode and action method.
3 • Check in detail the troubled parts according to the sequence of "trouble shooting by the phenomena".
1. Is proper the power voltage?The power voltage shall be of 198V-264V 50Hz.
2. Is the cable connected correctly between the indoor and outdoor unit?The indoor and outdoor units shall be connected with 8 wires including the grounding.Check whether the wires of indoor and outdoor units are connected with the correct wire no. and terminal board no.
3. The phenomena in the following table is not related to the fault of air conditioner.
- Heating operationThe compressor does not operated even though the settemperature is set higher than the indoor temperature.
- Cooling operation The compressor does not operated even though the settemperature is set lower than the indoor temperature.
- Fan speed is not adjusted during the auto, dry, turbo andlong operation.
- The temperature is not adjusted during the auto, dry, turboand long and fan operation.
- The compressor repeats the stop and start with the inter-val of several minutes during dry.
- During the heating operation, the lamp on "deice" is on atthe control panel and the compressor operates.
- During the heating, the outdoor unit fan motor repeatsstart/stop or even the compressor repeats the start andstop.
- During the heating, the compressor and outdoor unit fanmotor operate but indoor unit fan motor does not operate.
1
2
3
4
5
6
7
Phenomena Description
- The operation of compressor is delayed for 3 minutes forthe protection of compressor when it is off and on again.
- The compressor operates normally after 3 minutes even thelnitial power is on.
- The fan speed is automatically adjusted during the auto,dry, turbo and long operation.
- The set temperature is automatically set during the auto,dry and long operation.
- The wind blow operation is the mode to circulate the indoorair.
- At the dry operation, the set temperature and the indoortemperature are compared to adjust the compressorstart/stop time in order to dehumidify.
- The deice operation is being performed in order to melt thefrost by outdoor unit and its maximum time is 9 minutes.
- It is the function to prevent the overheating of the indoorevaporator, where the temperature of indoor unit heatexchanger reaches 52°C, the normal operation is done.
- This is the function to prevent the cooling air incoming tothe indoor, where the temperature of indoor evaporatorreaches 27°C, the indoor fan motor operates.
No
5. Troubleshooting
5-1 The Items to be checked first time
25Samsung Electronics
5-2 Display of the result of self-diagnostic and check items on the control panel
Error Type LED Mark
Gas Sensor Error (Open)
Room Temperature Sensor Error (Open/Short)
Auto Shutter Error
Perfect Air Cleaning Fan Motor Error
Communication Error between
Main PCB and Panel PCB
Indoor Pipe Temperature Sensor (Open/Short)
Outdoor Pipe Temperature Sensor (Open/Short)
- Check the Gas Sensor voltage(0V~5V).
- Check the connection wire.
- Check the Temperature Sensor.
- Check the main PCB pattern and wire Open/Short.
- Check the Auto Shutter Sensor.
- Check the Sensor and Motor-driven wire.
- Check the mechanical lock.
- Check the RPM Feedback wire.
- Check the Motor wire.
- Check the wire between Main and Panel.
- Check the CN901 Connector voltage of the Main PCB.
(5 ↔ 1 : 12V, 5 ↔ 2 : 5V)
- Check both the connection wire and the Temperature Sensor.
- Check both the connection wire and the Temperature Sensor.
Measures
Samsung Electronics26
1. Causes of Failure1) Power voltage out of the motion boundary or poor power cord contact.2) Main PCB fuse cut or poor PCB.3) Poor panel PCB, poor assembly of tact switch, poor LED display.
2. Inspection Items1) Power voltage? (AC198V ~ AC264V)2) Power cord contact?3) Power fuse(F701) and PCB fuse(F101)?4) Output voltage of U303(KA7805) (DC4.5V ~ DC5.5V)?5) Connection harness between Main PCB and panel PCB?
3. Inspection Procedure
Turn power off and on in 5 seconds.
Press OPER key. LED Lightson and shutter open?
Check U303 output voltage, 5V?
Check voltage of CN901 #1 ↔ 5 of panelPCB, 12V? If yes, then Inspect and
exchange panel PCB(Poor panel PCB).
Power voltage normal (Fuse : AC ↔ AC)?AC198V ~ AC264V
Good set operation
Check wire between indoor unit &outdoor unit. Exchange wire.
Inspect and exchange Main PCB.
No
Yes
Yes
Yes
No
No
5-3 Troubleshooting by Phenomena
5-3-1 When it is not Power on. (When it is not Displayed.)
Troubleshooting
27Samsung Electronics
1. Causes of Failure1) Power voltage out of the motion boundary or poor power cord contact.2) Poor motor driving condenser or poor contact.3) Motor cut or short.4) Connecting harness cut or poor contact.5) Poor Main PCB : poor relay (RY705 ~ RY708)
2. Inspection Items1) Power voltage? (AC198V ~ AC264V)2) Connection of motor connecting harness?3) Contact of Fan motor driving condenser terminal?
3. Inspection Procedure
Turn power off and on in 5 seconds.
Check indoor Fan motor edge voltage, AC220V?
Inspect and exchange indoor Fan motor.
Control both operating mode key andremote control key to enter ''FAN'' mode.
Select Turbo, High, Medium or Low byFanspeedkey, thensee ifRY708(Low), RY707(Medium),
RY706(High), or RY705(Turbo) operates.
Check Fan speed output wave style of pinsNo. MICOM(U101)#20, 21, 22 and 23 "HIGH"?
Check relay coil edge voltage for eachFan speed(Turbo/High/Medium/Low), DC12V?
Select Turbo, High, Medium or Low by Fan speedkey, then check the speed of Indoor Fan Motor.
Good Indoor Fan motor
Good relay
MICOM(U101) Inspection andexchange
Check connecting harness cut.
Check Fan speed outputwave style of pins
No. U104 #10, #11, #12and #13, "LOW"?
Inspect andexchange U104.
No
No
Yes
Yes Yes
Yes
Yes
Yes
No
No No
No
5-3-2 When Indoor Fan Motor does not operate.
Troubleshooting
Samsung Electronics28
1. Causes of Failure1) Power voltage out of the motion boundary or poor power cord contact.2) Poor wiring or poor contact between indoor and outdoor.3) Poor Main PCB : poor relay (RY702)
2. Inspection Items1) Power voltage? (AC198V ~ AC264V)2) Wiring and contact between indoor and outdoor?3) Compressor to check out 3 minutes delay(stand-by)?4) Set temperature for "Cooling", comparing with current temperature?
3. Inspection Procedure
Turn power off and on in 5 seconds.
Exchange compressor.
Start cooling by remote control, both relay(RY702) and compressor on in
3 minutes?
Check Fan speed outputwave style of pins No. MICOM(U101) #26 during
compressor on, "HIGH"?
Check relay(RY702) coil edge voltage during compressor on, DC12V?
Outdoor power type : check edgeNo. 1 ↔ 3 of wire between indoor and outdoor
during compressor on.
Good compressor and relay
Inspect and exchangeMICOM(U101).
Inspect and exchangepower relay(PCB position).
Check Fan speed outputwave style of pins No. U104
#16, "LOW"?
Inspect andexchange U104.
No
Yes
Yes
Yes
Yes
Yes
No
No
No
No
5-3-3 When Compressor does not operate.
Troubleshooting
29Samsung Electronics
1. Causes of Failure1) Cut or poor contact of motor connecting harness of the Air flow blade(right/left) of left side.2) Defect by device hanging.3) Poor Main PCB.4) Poor stepping motor.
2. Inspection Items1) Contact of motor connecting harness of the Air flow blade(right/left) of left side?2) Output wave style from panel PCB port(PORT) during motor on?
3. Inspection Procedure
Turn on and turn the Air flow blade(right/left)on with remote control.
Exchange the Air flow blade(right/left) of left side.
Check swing of the Air flow blade(right/left)of left side, OK?
Check connector wire, cut or wrong?
Check voltage between Main PCBCN201 No. #5, 6 and GND, DC12V?
Check wave style from Main PCBCN201 No. #1, #2, #3, #4 spherical?
Good motor of the Air flowblade(right/left) of left side.
Inspect and exchangeconnection Harness.
Inspect and exchange U202.
Exchange Panel PCB.
No
Yes
No
Yes
Yes
Yes
No
No
5-3-4 When the Air flow blade(right/left) of Left side does not operate.
Troubleshooting
Samsung Electronics30
1. Causes of Failure1) Cut or poor contact of motor connecting harness of the Air flow blade(right/left) of right side.2) Defect by device hanging.3) Poor Main PCB.4) Poor stepping motor.
2. Inspection Items1) Contact of motor connecting harness of the Air flow blade(right/left) of right side?2) Output wave style from panel PCB port(PORT) during motor on?
3. Inspection Procedure
Turn on and turn the Air flow blade(right/left)on with remote control.
Exchange the Air flow blade(right/left) of right side.
Check swing of the Air flow blade(right/left)of right side, OK?
Check connector wire, cut or wrong?
Check voltage between Main PCBCN201 No. #11, 12 and GND, DC12V?
Check wave style from Main PCBCN201 No. #7, #8, #9, #10, spherical?
Good motor of the Air flowblade(right/left) of right side.
Inspect and exchange connection harness.
Inspect and exchange U202.
Exchange panel PCB.
No
Yes
No
Yes
Yes
Yes
No
No
5-3-5 When the Air flow blade(right/left) of right side does not operate.
Troubleshooting
31Samsung Electronics
1. Causes of Failure1) Cut or poor contact of motor connecting harness of the Air flow blade(up/down).2) Defect by device hanging.3) Poor Main PCB.4) Poor stepping motor
2. Inspection Items1) Contact of motor connecting harness of the Air flow blade(up/down)?2) Output wave style from panel PCB port(PORT) during motor on?
3. Inspection Procedure
Turn on and turn the Air flow blade(up/down)on with remote control.
Exchange the Air flow blade(up/down).
Check swing of the Air flow blade(up/down), OK?
Check connector wire, cut or wrong?
Check voltage between Main PCBCN202 No. #5 and GND, DC12V?
Check wave style from Main PCBCN202 No. #1, #2, #3, #4, spherical?
Good motor of the Air flowblade(up/down)
Inspect and exchangeconnection harness.
Inspect and exchange U204.
Exchange panel PCB.
No
Yes
No
Yes
Yes
Yes
No
No
5-3-6 When the Air flow blade(up/down) does not operate.
Troubleshooting
Samsung Electronics32
1. Causes of Failure1) Low remote control voltage.2) Poor receiving module of panel PCB remote control.
2. Inspection Items1) Check "Beep" sound from the indoor unit panel. This indicates normal signal transmission from remote control.
3. Inspection Procedure
Turn power off and on in 5 seconds.
Check wave style from panel PCB MICOMU101 Pin No. #20, spherical?
Press On/Off button on panel, then realtemperature displayed and start running?
Press On/Off button on remote control,then "Beep" sound and stop running?
Check remote control battery voltage, over DC2.5V?
Exchange panel PCB MICOM(IC101).
Press On/Off button on remote controlafter exchanged, in normal operation?
Check the inspection itemsduring power off.
Exchange remote control.
Exchange panel PCBreceiving module.
Normal
Exchange the battery.
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
5-3-7 When remote control does not operate.
Troubleshooting
33Samsung Electronics
1. Causes of Failure1) HVPS connecting harness cut or poor contact.2) Reed switch harness cut, wrong wiring, or poor contact.3) Dust collecting plate short.4) Poor part of HVPS.
2. Inspection Items1) Connection of HVPS connecting harness?2) Connection of reed switch harness?
3. Inspection Procedure
Turn power off and on in 5 seconds.
Check voltage betweenHVPS input edges, DC12V?
Power on and Air cleaner on with remote control.
Check voltage between CN710No. #1 ↔ #2, DC12V?
Check MICOM Pin No. #23, "HIGH"?
Inspect and exchange HVPS assembly
✳ You are not able to check the input voltage of HVPS unless Reed switch contacts the magnet.
Check MICOM Pin No. #15, "LOW"? Inspect and exchange U12.
Check if the connectingharness was cut.
Inspect and exchangeMain PCB.
Inspect and exchangeMICOM(U101).
Yes
Yes
Yes
Yes
No
No
No
No
5-3-8 When Dust Collector does not operate.
Troubleshooting
Samsung Electronics34
1. Causes of Failure1) Perfect(Electrostatic dust collector) breakdown.2) Reed switch harness cut or poor contact.3) Poor anion generator connecting harness.4) Poor part of anion generator.
2. Inspection Items1) Connecting harness?2) Connection of reed S/W harness?
3. Inspection Procedure
Turn power off and on in 5 seconds.
Check voltage betweenCN710 No. #3 and CN707 No. #4, DC12V?
Perfect on and Anion generator on.
Check voltage between Anion generator inputconnector No. #1 ↔ 3, DC12V?
Check voltage of MICOM Pin No. #44, 5V?
Check voltage between HVPS white connectorNo. #1 ↔ 3, DC12V?
Exchange anion generator.
Check voltage between CN707 No. #3 ↔ #4, 12V?
Exchange anion generator.
Exchange the connectingharness.
Exchange Main PCB.
Exchange reed switch.
Yes
No
Yes
Yes
Yes
No
No
No
No
5-3-9 When Anion Generator does not operate.
1. Be sure to put PERFECT into cleaning to run the Anion Generator.2. Reed S/W shall remain contact with the magnet for its operation, too.
Troubleshooting
35Samsung Electronics
1. Causes of Failure1) Motor & Sensor PCB connecting harness cut or poor contact.2) Poor Main PCB3) Poor device
2. Inspection Items1) Connecting harness?2) Voltage of MICOM #33 while shutter operates. This shall be 5V; otherwise Main PCB must be poor?
3. Inspection Procedure
Turn power off and on in 5 seconds.
Power on or off.
Rise with shutter. Descend with shutter.
Check voltage betweenCN704 No. #1 ↔ #5, 220V?
Check voltage betweenCN704 No. #1 ↔ #5, 220V?
Defection of bothshutter and motor
Defection of bothshutter and motor
Exchange Main PCB.
Exchange Relay.- RY709 : Exchange in case poor Open.- RY710 : Exchange in case poor Close.
Check coil voltages of RY709(Open) andRY710(Close), DC12V?
No
No
Yes
YesYes
5-3-10 When Auto Shutter does not operate.(" " Error Mode)
Troubleshooting
Samsung Electronics36
1. Causes of Failure1) Motor & Sensor PCB connecting harness cut or poor contact.2) Poor motor3) Poor Main PCB
2. Inspection Items1) Connecting harness of motor connector?2) Operability of outdoor unit? If yes, Main PCB must be poor.3) Operability of Fan motor while outdoor unit is running. If yes, motor must be poor.4) Cold lead remnant in Main PCB 501 condenser(450V 1.2uF).
3. Inspection Procedure
Turn power off and on in 5 seconds.
Power on and Perfect Air Cleaning on.
Check voltage between CN501 No. #3 ↔ #5, 220V?
Check CN502 connecting harness.
Exchange Fan motor.
Exchange Main PCB.
Reconnect connector.
Yes
Yes
No
No
5-3-11 When Perfect Fan Motor does not operate.(" " Error Mode)
MEMO
37Samsung Electronics
Samsung Electronics38
12
13
11
8-1
8-2
1
10
10-1
14
17
15
9
6 5
7
2
43
2-3 2-2
2-1
1-1
16
7-1
7-3
7-2
4-1
8
10-2
You can search for the updated part codenumber through the ITSELF.URL : http://itself.sec.samsung.co.kr
6. Exploded Views and Parts List
6-1 Indoor Unit
39Samsung Electronics
Exploded Views and Parts List
� Parts List
1 DB98-21999D ASS'Y-CABINET UNIT HP-S182P,SUPREME-PJT 1 1 SNA
1-1 DB63-00333A COVER-CAP CABINET L-P/J,HIPS,T2,-,-,-,-, 1 1 SA
2 DB94-00519B ASS'Y-DIE BOTTOM APH289SEF/XFO,SUPREME-PJ 1 1 SNA
2-1 DB64-00579E DECO DIE-BOTTOM HP-S182P,HIPS,T3.0,358.9 1 1 SA
2-2 DB61-01041B BRACKET-TERMINAL KFRD-70LW/SSA,SGCC-M,T1 1 1 SNA
2-3 2301-001380 C-FILM,LEAD-OTHER 4500nF,+10-5%,450V,BK, 1 1 SA
3 DB63-00519A COVER-TERMINAL AP-SR2370,ABS(V0),-,-,-,- 1 1 SC
4 DB31-00161C MOTOR FAN-OSME 618SAC OSM 618SAC,-,-,50, 1 1 SA
4-1 DB73-00078A GROMMET-MOTOR IN -,NBR,-,-,-,-,-,BLK,C1- 3 3 SA
5 DB67-00288A BLOWER AP-SR2370,ABS+GF10%,324,1,3.5, 1 1 SA
6 DB60-30027A SCREW-MACHINE HEX,2C,M12,ZPC3,SCP1,- 1 1 SA
7 DB90-01343A ASS'Y-DUCT CASE HP-S2371,SUPREME P/J 1 1 SA
7-1 DB67-00242A DUCT-CASE AP-SR2370,HIPS,-,-,-,GREY,SUPR 1 1 SA
7-2 DB63-00520A COVER-GAS SENSOR AP-SR2370,HIPS,-,-,-,-, 1 1 SNA
7-3 DB93-00368B ASS'Y PCB-GAS SENSOR SP3S-AQ2,LEAD FREE 1 1 SA
8 DB94-00477B ASS'Y-PANEL DRAIN HP-S2371,ABS 1 1 SA
8-1 DB64-00580A PANEL-DRAIN AP-SR2370,ABS,-,-,-,-,GREEN, 1 1 SC
8-2 DB94-00315P ASS'Y-HOSE DRAIN HP-SR2371GB,SUPREME-PJT 1 1 SA
9 DB90-01344A ASS'Y-BELL MOUTH HP-S2371,SUPREME P/J 1 1 SA
10 DB90-01414B ASS'Y COVER-TOP HP-S182P,Supreme 1 1 SA
10-1 DB63-00544D COVER-TOP HP-S182P,HIPS,T2.5,209.2,523,- 1 1 SNA
10-2 DB94-00244A ASS'Y-COVER TOP INNER AP-SR2370,SUPREME-P 1 1 SA
11 DB63-00523A COVER-EVAP RH AP-SR2370,HIPS,-,-,-,-,-,G 1 1 SA
12 DB63-00524A COVER EVAP-LF AP-SR2370,HIPS,-,-,-,-,-,G 1 1 SA
13 DB96-04683C ASS'Y EVAP-PARTS APH289SEF/XFO,SUPREME-PJ 1 1 SNA
14 DB98-22262G ASS'Y-SHUTTER HP,KFRD-70L/SSF,6uF,-,-,720 1 - SA
DB98-22262F ASS'Y-SHUTTER SATIN SILVER,HP,KFRD-70L/SSF,6uF,-,-,720 - 1 SA
15 DB98-21625A ASS'Y-INLET HP,HP-S182P,-,-,-,-,-,-,-,-,- 1 1 SNA
16 DB94-00517A ASS'Y-PERFECT CLEANER APH289SE,CIS TYPE 1 1 SNA
17 DB98-21626E ASS'Y-PANEL DISPLAY CO,SUPREME-PJT,-,-,-, 1 1 SNA
Code No. Description SA/SNANo.Q'TY
APH289SEF APH289SEGSpecification
3
429
27
2819
14
18
151817
13
24
26
15
22
6
25
12
21
209
10
7
85
1
11
23
16
16
2
Samsung Electronics40
Exploded Views and Parts List
6-1-1 ASS'Y-SHUTTER-Indoor Unit No.14
41Samsung Electronics
Exploded Views and Parts List
� Parts List
14 DB98-22262F ASS'Y-SHUTTER SATIN SILVER,HP,KFRD-70L/SSF,6uF,-,-,720 - 1 SA
DB98-22262G ASS'Y-SHUTTER TROPICAL RED,HP,KFRD-70L/SSF,6uF,-,-,720 1 - SA
14-1 DB61-01589B FRAME-OUTLET SR HP-S182P,HIPS,-,-,SC-026 1 1 SNA
14-2 DB64-01049A GLASS-OUTLET TROPICAL RED,HP-S2371R,TEMPERED GLASS,1.6,44 1 - SA
DB64-01049D GLASS-OUTLET SATIN SILVER,HP-S2371V,TEMPERED GLASS,1.6,44 - 1 SA
14-3 DB63-01190A COVER-OUTLET LF HP-S232P,HIPS,-,-,-,-,-, 1 1 SA
14-4 DB63-01191A COVER-OUTLET RH HP-S232P,HIPS,-,-,-,-,-, 1 1 SA
14-5 DB63-00530D COVER-OUTLET TOP HP-S182P,HIPS,T3.0,78.6 1 1 SA
14-6 DB61-01476B BODY-OUTLET HP-SR2371,HIPS,T2.5,C81305,- 1 1 SA
14-7 DB64-00581B PANEL-SHUTTER SR HP-S182P,ABS,T2.5,250.2 1 1 SA
14-8 DB64-01066A GLASS-SHUTTER HP-S2371R,TEMPERED GLASS,1.6,4 1 - SA
DB64-01066D GLASS-SHUTTER HP-S2371V,TEMPERED GLASS,1.6,4 - 1 SA
14-9 DB61-01028A HINGE-SHUTTER UP AP-SR2370,ABS,-,-,-,BLK 1 1 SC
14-10 DB61-01029A HINGE-SHUTTER LOW AP-SR2370,ABS,-,-,-,BL 1 1 SC
14-11 DB63-00531A COVER MOTOR-V AP-SR2370,HIPS,-,-,-,-,-,- 2 2 SC
14-12 DB66-00358A GEAR-SHUTTER AP-SR2370,POM,-,-,-,BLACK,- 1 1 SA
14-13 DB66-00355B BLADE-H MOTOR HP-SR2371,HIPS,-,-,WHITE,S 1 1 SA
14-14 DB66-00359B BLADE-H HP-SR2371,HIPS,-,-,WHITE,S-PJT 5 5 SA
14-15 DB66-00356B BLADE-V MOTOR HP-SR2371,HIPS,-,-,WHITE,S 2 2 SC
14-16 DB66-00360B BLADE-V HP-SR2371,HIPS,-,-,WHITE,S-PJT 6 6 SA
14-17 DB66-00353A LINK-BLADE H AP-SR2370,POM,-,-,-,BLACK,S 2 2 SA
14-18 DB66-00354A LINK-BLADE V AP-SR2370,POM,-,-,-,BLACK,S 2 2 SA
14-19 DB61-02179A SUPPORT-LINK BLADE H AP-N231P,POM,-,20,2 1 1 SA
14-20 DB66-00361A GEAR RACK AP-SR2370,ABS,-,-,-,BLACK,-,SU 1 1 SA
14-21 DB61-01032A HOLDER-HINGE AP-SR2370,POM,-,-,-,NATURAL 2 2 SA
14-22 DB31-00228A MOTOR GEARD -,NOVA-PJT,-,-,-,-,-,50/60,2 1 1 SA
14-23 DB31-00227A MOTOR STEP -,NOVA-PJT,-,-,1500gf.cm,12V 1 1 SC
14-24 DB31-00227B MOTOR STEP -,NOVA-PJT,-,-,1500gf.cm,12V 1 1 SA
14-25 DB31-00227C MOTOR STEP -,NOVA-PJT,-,-,1500gf.cm,12V 1 1 SA
14-26 DB93-10552A ASS'Y PCB SUB AP-431P,32*32 1 1 SA
14-27 DB94-00525B ASS'Y-CASE MAIN PCB AP-N2390F,NOVA-PJT 1 1 SA
14-28 DB93-02594D ASS'Y PCB MAIN S-CIS(RUSSIA),APH289SE 1 1 SA
14-29 DB90-01358A ASS'Y COVER-EVAP HP-SR2371,S-PJT 1 1 SNA
Code No. Description SA/SNANo.Q'TY
APH289SEF APH289SEGSpecification
Samsung Electronics42
Exploded Views and Parts List
10
3
7
5
6
9
7
4
11
1
8
2
6-1-2 ASS'Y-INLET-Indoor Unit No.15
43Samsung Electronics
Exploded Views and Parts List
� Parts List
15 DB98-21625A ASS'Y-INLET HP,HP-S182P,-,-,-,-,-,-,-,-,- 1 1 SNA
15-1 DB61-01590B FRAME-INLET HP-S182P,HIPS,-,-,SC-02684R, 1 1 SNA
15-2 DB64-01048A GLASS-INLET TROPICAL RED,HP-S2371R,TEMPERED GLASS,1.6,447 1 - SA
DB64-01048D GLASS-INLET SATIN SILVER,HP-S2371V,TEMPERED GLASS,1.6,447 - 1 SA
15-3 DB63-00532C COVER-INLET LF HP-SR2371,HIPS,-,-,-,-,-, 1 1 SA
15-4 DB63-00533C COVER-INLET RH HP-SR2371,HIPS,-,-,-,-,-, 1 1 SA
15-5 DB64-00591C GRILLE-INLET LF HP-SR2371,HIPS,-,-,-,-,- 1 1 SA
15-6 DB64-00592C GRILLE-INLET RH HP-SR2371,HIPS,-,-,-,-,- 1 1 SA
15-7 DB63-00547B FILTER-PRE HP-S2371,COMPOSITE PP,3.5,100.0,688 2 2 SA
15-8 DB61-01036A GUIDE-INLET AIR AP-SR2370,HIPS,-,-,-,-,S 1 1 SC
15-9 DB61-01023A PLATE-SPRING-A AP-SR2370,STS304,-,-,-,-,SU 1 1 SNA
15-10 DB61-01024A PLATE-SPRING-B AP-SR2370,STS304,-,-,-,-,SU 1 1 SNA
15-11 DB94-00310B ASS'Y-MAGNET HP-SR2370,SUPREME 2 2 SA
Code No. Description SA/SNANo.Q'TY
APH289SEF APH289SEGSpecification
Samsung Electronics44
Exploded Views and Parts List
9
5
11
2
8
37
1
10
12
4
6
6-1-3 ASS'Y-PERFECT CLEANER-Indoor Unit No.16
� Parts List
16 DB94-00517A ASS’Y-PERFECT CLEANER APH289SE,CIS TYPE 1 SNA
16-1 DB61-01591A GUIDE-C-FAN-UP HP-SR2371GB,HIPS,-,-,-,-, 1 SNA
16-2 DB61-01592A GUIDE-C-FAN-LOW HP-SR2371GB,HIPS,-,-,-,- 1 SNA
16-3 DB63-00546A GUARD-ELECTRIC FILTER AP-SR2370,MSWR,T=2 1 SA
16-4 DB63-00534A COVER-MAGNET S/W AP-SR2370,HIPS,-,-,-,-, 1 SNA
16-5 DB61-01043A PLATE-HVPS AP-SR2370,STS304,-,-,-,-,SUPR 2 SNA
16-6 DB70-00173B PLATE-MAGNET HP-SR2370,SECC-P,1.0,60,34. 2 SNA
16-7 DB94-00248A ASS'Y-CROSS FAN AP-SR2370,SUPREME-PJT 1 SA
16-8 DB91-00297A ASS'Y ELECTRIC S-PJT,DC12V 1 SNA
16-9 DB94-00258A ASS'Y BEARING G-PJT,CR,BLK 1 SA
16-10 DB63-00536A COVER-HVPS DC AP-SR2370,HIPS(V0),-,-,-,- 1 SC
16-11 DB91-00252A ASS'Y ELECTRIC-IONIZER AC-050C,-ION 1 SA
16-12 DB91-00254A ASS'Y ELECTRIC-FILTER APH289SE,CIS TYPE 1 SA
Code No.No. Specification Q'TY SA/SNADescription
45Samsung Electronics
Exploded Views and Parts List
1
5
6
7
4
3
2
6-1-4 ASS'Y-PANEL DISPLAY-Indoor Unit No.17
� Parts List
17 DB98-21626E ASS'Y-PANEL DISPLAY CO,SUPREME-PJT,-,-,-, 1 SNA
17-1 DB63-00834B COVER-DISPLAY SR HP-S182P,HIPS,T2.0,135. 1 SNA
17-2 DB66-00357C BLADE-CLEANER HP-S182P,ABS,2.0,-,SC-0162 1 SA
17-3 DB64-01051A INLAY-WINDOW HP-SR2371GB,TRANSPARENCY ACRYL,1.0 1 SA
17-4 DB64-00959A BUTTON-CONTROL HP-SR2371GB,HIPS,-,-,-,SU 1 SNA
17-5 DB94-00524A ASS'Y-COVER PANEL PCB HP-S2371B,- 1 SA
17-6 DB93-01419F ASS'Y PCB DISPLAY S-CIS(APH289SE),PANEL,N 1 SA
17-7 DB95-20138A ASS'Y MOTOR-STEPPING GSP-24RW-046,AS-568 1 SA
Code No.No. Specification Q'TY SA/SNADescription
Samsung Electronics46
6
54
3
11
16 15-2
15-4
18
8
2
14
12
15-1
15
15-3
17
1
7
13
9
10
6-2 Outdoor Unit
47Samsung Electronics
Exploded Views and Parts List
� Parts List
1 DB90-00565C ASS'Y CABINET FRONT APH-H2320, 1 SA
2 DB90-20157K ASS'Y BASE OUT AP-7550,SC-90073T 1 SNA
3 DB67-00140A PROPELLER-FAN OUT AS+GF 20%,BLK,OD460,B- 1 SA
4 DB60-20021J BOLT-WELD -,M8,L39,-,-,- 4 SNA
5 DB31-00136B MOTOR FAN 0SME-1056SRC(S,F2K-PJT,-,-,-,- 1 SA
6 DB90-00967A ASS'Y-BRACKET MOTOR APH-H2320,H-P/J 1 SA
7 DB94-00359C ASS'Y PARTITION APH289SE,CIS 1 SNA
8 DB98-23550A ASS'Y-COND UNIT APH289SEN/XFO,SUPREME-PJT 1 SNA
9 DB90-40176A ASS'Y COVER-CONTROL C-PROJECT,HIPS,INSU 1 SA
10 DB90-00568E ASS'Y CABINET-SIDE RH APH289SE,CIS TYPE 1 SA
11 DB90-00569A ASS'Y CABINET-UPPER AP-L23✳✳,- 1 SA
12 DB95-10243B ASS'Y COMP APH-701H,ZR34K3-PFJ 1 SA
13 DB60-30028A SCREW-MACHINE HEX,2C,M8,ZPC,-,- 4 SA
14 DB73-10023A GROMMET-COMP -,EPDM,T41,-,-,-,-,BLK,- 4 SNA
15 DB93-02606A ASS'Y CONTROL-BOX OUT HP,-,-,-,-,-,-,-,-, 1 SA
15-1 DB34-90057C SWITCH-MAGNET 45CG20ALB,-,-,-,220/240V20 1 SA
15-2 2301-001369 C-FILM,LEAD-OTHER 3000nF,+10-5%,450V,BK, 1 SA
2501-001240 C-OIL 50uF,450V,BK,53x125mm,20.6 1 SA
15-3 DB65-40062Q TERMINAL BLOCK APH289SE,7P,12345NL,300V, 1 SA
15-4 DB95-90026B ASS'Y-SPARK KILLER PAC,- 1 SA
16 DB63-00369B FILTER-COMP SOUND APH289SE,PVC SHEET &GR 1 SNA
17 DB96-03125A ASS'Y TUBE-CHECK VALVE APH289SE,CIS TYPE 1 SNA
18 DB96-03043A ASS'Y TUBE-4WAY VALVE APC503QF,CIS TYPE 1 SNA
Code No.No. Specification Q'TY SA/SNADescription
Samsung Electronics48
7. Block Diagram
Compressor Indoor Fan Motor
Air Flow Blade Motor(up/down)
Air Flow Blade Motor 1(right/left)
Perfect Air Cleaning
Anion
Air Flow Blade Motor 2(right/left)
Auto Shutter Control
Load Drive Part
Remote ControlSensor Part
MICOM
ASS'Y PANEL PCB
MICOM
Reset Part
ASS'Y MAIN PCB
DC Power Part(5V)
DC Power Part(12V)
Indoor RoomTemperature Sensor
Outdoor PipingTemperature Sensor
Gas Sensor
Buzzer Control
Indoor PipeTemperature Sensor
AC Power Part
AC 220-240V/50Hz
Key Input Part
Communication Part
Display Part
Remote Controller
49Samsung Electronics
8. PCB Diagram
8-1 ASS'Y MAIN PCB : DB93-02594D
� TOP
� BOTTOM
Samsung Electronics50
� Parts List
C703 C-CHIP 1nF,10%,50V,X7R,TP,2012 1
C105,106,502 C-CHIP 10nF,+80-20%,50V,Y5V,TP,2012 3
C101,103,112,203 C-CHIP 100nF,+80-20%,50V,Y5V,TP,2012 8
C302,307,405,702
J5 R-CHIP 0 ohm-J,1/8W,DA,TP,3216 1
R106,409 R-CHIP 330ohm-J,1/10W,DA,TP,2012 2
R108,109,501,503 R-CHIP 1Kohm-J,1/10W,DA,TP,2012 4
R502 R-CHIP 6.8Kohm-J,1/10W,DA,TP,2012 1
R110 R-CHIP 10Kohm-J,1/10W,DA,TP,2012 1
R104 R-CHIP 27Kohm-J,1/10W,DA,TP,2012 1
R203 R-CHIP 1Mohm-J,1/10W,DA,TP,2012 1
Q501 TR-SMALL SIGNAL 2SC2412K,NPN,200mW,SOT-23,TP 1
ZD304 DIODE-ZENER BZX84C3V6,3.6,350mW,SOT-23,TP 1
D301 DIODE-BRIDGE DF06S,600V,1A,SMD-4,TP 1
U103,104,U202~U204 TR-ARRAY ULN2003AFW,NPN,7,1W,SOP-16,ST,1000 5
U101 MICOM SEC,64-QFP 1
C401,402,403 C-CERAMIC 100nF,+80-20%,50V,Y5V,TP,3.5x1 3
J1~J4,J6~J13 JUMP WIRE 50mm 40
J15~J21,J23~J43
R304 R-CARBON 47ohm-J,1/8W,AA,TP,1.8x3.2mm 1
R303 R-CARBON 150ohm-J,1/8W,AA,TP,1.8x3.2mm 1
R405,406,407 R-CARBON 330ohm-J,1/8W,AA,TP,1.8x3.2mm 3
R301 R-CARBON 6.8ohm-J,1/8W,AA,TP,1.8x3.2mm 1
R401,402,403 R-METAL 6.8Kohm-F,1/8W,AA,TP,1.8x3.2m 3
R702 R-CARBON 27Kohm-J,1/8W,AA,TP,1.8x3.2mm 1
R102 R-CARBON(S) 470ohm-J,1/2W,AA,TP,2.4x6.4mm 1
R701 R-METAL OXIDE 200Kohm-J,2W,AA,BK,5.5x16mm 1
D302 DIODE-TVS ST02D-170,155/170/185V,200W,DO-214 1
D303 DIODE-RECTIFIER SHK75-11,100V,3A,BK 1
D305 DIODE-ZENER MTZ11B,11V,10.5-11.05V,500mW,D 1
U105 IC-VOLTAGE KA7533,TO-92,3P,-,SINGLE,-,-,PLASTIC 1
X101 RESONATOR-CERAMIC 10MHz,0.5%,TP,10.0x5.0x8.0mm 1
C104 C-AL 1uF,20%,50V,GP,TP,5x11,5 1
C102 C-AL 47uF,20%,25V,GP,TP,5x11,2.5 1
C303,306,308 C-AL 470uF,20%,25V,GP,TP,10x12.5mm 3
NTC301 THERMISTOR-NTC 22ohm,1.4A,3100K,9.5MW/C,-,7.0 1
L301 INDUCTOR-RADIAL 4.7UH,10%,6.5x7.5mm 1
U301 IC-PWM CONTROLLER TNY267P,DIP,8P,9.65x6.35mm,PLASTIC 1
U302 PHOTO-COUPLER PC817B,130-260%,200mW,DIP-4,ST 1
U701 PHOTO-COUPLER PC814X1,50-150%,200mW,DIP-4,ST 1
Specification Q'TYDescriptionLocation No.
PCB Diagram
51Samsung Electronics
PCB Diagram
F101 FUSE-CARTRIDGE 250V,F1A,FUSE 1
F701 FUSE-CARTRIDGE 250V,3.15A,TIME-LAG,GLASS,5x20mm 1
F701,F101 HOLDER FUSE FB58-20 2
VA701 VARISTOR INR14D561K-RS,560V,2500A,17.5x7.5mm,TP 1
C305 RC-NETWORK RC-NETWORK(2.2nF+12Mohm) 1
C501 C-FILM,MPPF 1.2uF,10%,450Vac,BK,38x18x30,3 1
C301 C-AL 22uF,20%,450V,LZ,BK,16x25mm,7.5 1
C701,705 C-FILM,PCF 220nF,10%,275V,BK,18X12X6,15 2
C706 C-FILM,MPPF 0.14ßfi,10%,600VAC,BK,25.6x15.0 1
U303 IC-POSI.FIXED REG. KA7805,TO-220,3P,-,PLASTIC,4.8/5 1
U303 HEAT SINK A6063,L25.5 W15,WHT 1
U303 SCREW-TAPPING PH,M3,L8,FE FZY 1
L701 NOISE-FILTER LS404190M,AS-S660,19mH,+50,-30%,-,300Mohm,2A 1
U501 SSR G3MB202PL,12Vdc,-,2A,1mS,1mS 1
RY702~RY710 RELAY-POWER US11-12S1, DC12V,3A 9
T301 TRANS SWITCHING S-PJT,AP-S2370,-,220V,-,-,EE2216 1
CN101 CONNECTOR-HEADER SMW200-03, YEL 1
CN201 CONNECTOR-HEADER SMW200-06, YEL 1
CN202 CONNECTOR-HEADER SMW200-06, WHT 1
CN203 CONNECTOR-HEADER SMW200-05, WHT 1
CN204 CONNECTOR-HEADER SMW200-06, RED 1
CN401 CONNECTOR-HEADER SMW200-06, BLU 1
CN403 CONNECTOR-HEADER SMW200-03, WHT 1
CN501 CONNECTOR-HEADER YW396-05AV, WHT 1
CN502 CONNECTOR-HEADER SMW250-03, BLU 1
CN701 CONNECTOR-HEADER YW396-05AV, BLU 1
CN702 CONNECTOR-HEADER YW396-03AV, BLU 1
CN703 CONNECTOR-HEADER YWL500-05, WHT 1
CN704 CONNECTOR-HEADER YW396-05AV, YEL 1
CN707 CONNECTOR-HEADER SMW200-04, WHT 1
CN710 CONNECTOR-HEADER SMW200-03, RED 1
CN901 CONNECTOR-HEADER SMW200-05, RED 1
DB41-00246A PCB BOARD FR-1, W250xH197.5, 1x2, (20617A) 1
DB93-02594D CODE LABEL STICKER 30mmx15mm 1
Specification Q'TYDescriptionLocation No.
� Parts List(cont.)
Samsung Electronics52
8-2 ASS'Y PANEL PCB : DB93-01419F
� TOP � BOTTOM
53Samsung Electronics
PCB Diagram
� Parts List
C120,121 C-CHIP 24pF-J/50V,2012 2
C110 C-CHIP 1nF,10%,50V,X7R,TP,2012 1
C106,107,602,603 C-CHIP 10nF,+80-20%,50V,Y5V,TP,2012 8
C801,802,901,902
C105,108,112 C-CHIP 100nF,+80-20%,50V,Y5V,TP,2012 6
C114,115,116
R102,103,109 R-CHIP 1Kohm,5%,1/10W,DA,TP,2012 3
R602,603 R-CHIP 2Kohm,5%,1/10W,DA,TP,2012 2
R111 R-CHIP 4.7Kohm,5%,1/10W,DA,TP,2012 1
R104,110,604,605 R-CHIP 10Kohm,5%,1/10W,DA,TP,2012 11
R801,802,901,902
R105,106,107
R108 R-CHIP 20Kohm,5%,1/10W,DA,TP,2012 1
R101 R-CHIP 1Mohm,5%,1/10W,DA,TP,2012 1
D901,902,903 DIODE-SWITCHING RLS4148 ,100V,200mA,DO-35,TP 10
D905,906,907
OP1~3,OP6
Q101,601 TR-SMALL SIGNAL KST2907A,PNP,350mW,SOT-23,TP,1 2
Q102 TR-SMALL SIGNAL 2SC2412K,NPN,200mW,SOT-23,TP,1 1
Q602,603 TR-DIGITAL KSR1102,NPN,200mW,10K/10K,SOT-23,TP 2
U101 IC MICOM S3C8245X30-QWR5,-,80P,+5V,10MHZ,STM-0019- 1
R601 R-CARBON 560ohm,5%,1/4W,AA,TP,2.4x6.4mm 1
J1~J21 JUMP WIRE 52mm 23
J24,J25
C109,111,601 C-AL 47uF,20%,25V,GP,TP,5x11,2.5 3
C113 C-AL 1uF,20%,50V,GP,TP,5x11,5 1
SW901,902,903 SWITCH-TACT JTP1280A6 15V,20mA,160gf+-50gf,6x3.4mm,S 6
SW905,906,907
U102 IC-VOLTAGE KA7533,TO-92,3P,-,SINGLE,-,-,PLASTIC 1
X101 RESONATOR-CERAMIC 10MHz,0.5%,TP,10.0x5.0x8.0mm 1
X102 CRYSTAL-UNIT 32,768KHz,20ppm,28AAY,12.5pF 1
CN901 CONNECTOR-HEADER SMAW200-05,WHT 1
LCD01 LCD 94-42221-B01, FSTN, 134x24.5x2.7 1
LCD01 LCD BACK LIGHT LUB-2055B1 1
U103 MODULE REMOCON-FRP FRP4021H6,38KHz 1
BZ601 BUZZER-PIEZO 80DB,9V,-,2.0KHz 1
SPREAD AT THE PART OF MICOM URETHANE INSULATION COATING MATERIAL UC-100(TRANSPARENCY) -
DB41-00081A PCB BOARD 330x50 FR-1 1
DB93-01419C CODE LABEL STICKER 30mmx15mm 1
Specification Q'TYDescriptionLocation No.
Samsung Electronics54
9. Wiring Diagram
9-1 Indoor Unit
This Document can not be used without Samsung's authorization.
Code No : DB98-15796A
VA701 VARISTOR RY705 MOTOR IN(TURBO) DRIVE RELAY
RTH ROOM THERMISTOR SENSOR RY706 MOTOR IN(HIGH) DRIVE RELAY
ETH EVAP. THERMISTOR SENSOR RY707 MOTOR IN(MED) DRIVE RELAY
RY702 COMP. DRIVE RELAY RY708 MOTOR IN(LOW) DRIVE RELAY
RY703 4-WAY V/V DRIVE RELAY RY709 SHUTTER MOTOR DRIVE RELAY(OPEN)
RY704 OUTDOOR FAN DRIVE RELAY RY710 SHUTTER MOTOR DRIVE RELAY(CLOSE)
ERROR MODE
"E0" GAS SENSOR ERROR "E5" EVAP. THERMISTOR ERROR
"E1" ROOM THERMISTOR ERROR "E6" COND. THERMISTOR ERROR
"E2" SHUTTER MOTOR ERROR "EA" MAIN-PANEL PCB COMMUNICATION ERROR
"E3" PERFECT CLEANER FAN MOTOR ERROR
55Samsung Electronics
This Document can not be used without Samsung's authorization.
9-2 Outdoor Unit
Code No : DB98-03401A
CM COMPRESSOR TP 1.2 TERMINAL PLATE
52C1 MAGNETIC CONTACTOR 20S SOLENOID COIL
CPC CAPACITOR FOR COMP SPK SPARK KILLER
FM FAN MOTOR 63H HIGH PRESSURE S/W
CPM CAPACITOR FOR MOTOR F1 FUSE(250V/2A)
Samsung Electronics56
10. Schematic Diagram
10-1 MAIN PCB
This Document can not be used without Samsung's authorization.
57Samsung Electronics
10-2 PANEL PCB
This Document can not be used without Samsung's authorization.
MEMO
Samsung Electronics58
MEMO
59Samsung Electronics
MEMO
Samsung Electronics60
ELECTRONICS
This Service Manual is a property of Samsung Electronics Co., Ltd.Any unauthorized use of Manual can be punished under applicableInternational and/or domestic law.
© Samsung Electronics Co., Ltd. Jun. 2005.Printed in Korea.Code No. DB98-18969A(2)