series q-03 directional control valve · a q - 3 pos. sp ring c ent d qj- 2 p os . spr ng ffset, l...
TRANSCRIPT
–––––
series Q-03 directional control
valve
4500 psi, 21 Gpm max
wet armature solenoid operated
536 TOWNSHIP LINE ROAD FLUID TECHNOLOGY ANNEX BLUE BELL, PENNSYLVANIA 19422 Tel: 215.643.0617 Fax: 216.643.4017 [email protected] www.doubleahydraulics.com
www.doubleahydraulics.com
–––––
series Q-03 directional control
valve
4500 psi, 21 Gpm max
wet armature solenoid operated
536 TOWNSHIP LINE ROADFLUID TECHNOLOGY ANNEXBLUE BELL, PENNSYLVANIA 19422Tel: 215.643.0617Fax: [email protected]
2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
®
four land spool
© 2018 Double A Hydraulics All rights reserved. Double A® Hydraulics is not related to Double A, a Division of Brown and Sharp.
SOLENOID COILS 120 VAC Nominal 12 VDC Response Time (ms) Switching
Frequency Intrusion Protection
Maximum Surface Temp
50 Hz 60 Hz
99-121 VAC 108-132 VAC
10.8-13.2 VDC
30 W AC DC
On 10-20
25-45
Off 15-40
10-25
AC
DC
7,200 cycles/hr 15,000 cycles/hr
Connector DIN (DN) DEUTSCH (DT)
IP 65 IP 69
AC DC
350 F 300 F
Q*-03-A-***-*-**-***
SPOOL SPRING COIL VOLTAGE ARRANGEMENT A120- 120 VAC 50/60 HZ QF- 3 POS. SPRING CENTERED D12- 12VDC
QG- 2 POS. SPRING OFFSET, SOL. A QF- 3 POS. SPRING CENTERED QJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTION QGF- 2 POS. SPRING CENTERED, SOL. A QJF- 2 POS SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN
DT- DEUTSCH
VALVE INTERFACE SEAL OPTION
03- NFPA D03 BUNA VITON
DESIGN CODE SPOOL FUNCTION AND TYPE
(SEE CHART ON NEXT PAGE)
MAXIMUM OPERATING PRESSURE
RELATED FLOW CAPACITY
MOUNTING BOLTS
P,A,B PORTS
T PORT
P,A,B T PORTS
10-24 X 2” 45-60 inch-#
4500 psi
2300 psi
21 gpm (DC)
16 gpm (AC)
Series Q-03 directional control valve
Specifications
Ordering Information
2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching
FrequencyIntrusionProtection
MaximumSurface Temp
50 Hz
60 Hz
99-121 VAC
108-132 VAC
10.8-13.2 VDC
30 WAC
DC
On10-20
25-45
Off15-40
10-25
AC
DC
7,200 cycles/hr15,000 cycles/hr
ConnectorDIN (DN)
DEUTSCH (DT)
IP 65
IP 69
AC
DC
350 F
300 F
Q*-03-A-***-*-**-***
SPOOL SPRING COIL VOLTAGEARRANGEMENT
A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQF- 3 POS. SPRING CENTEREDQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. AQJF- 2 POS SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN
DT- DEUTSCH
VALVE INTERFACE SEAL OPTION
03- NFPA D03 BUNAVITON
DESIGN CODE
SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)
MAXIMUM OPERATINGPRESSURE
RELATEDFLOWCAPACITY
MOUNTINGBOLTS
P,A,BPORTS
TPORT
P,A,B TPORTS
10-24 X 2”45-60 inch-#
4500 psi 2300 psi 21 gpm (DC)
16 gpm (AC)
Series Q-03directional control
valve
Specifications
Ordering Information
2018 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching
FrequencyIntrusionProtection
MaximumSurface Temp
50 Hz
60 Hz
99-121 VAC
108-132 VAC
10.8-13.2 VDC
30 WAC
DC
On10-20
25-45
Off15-40
10-25
AC
DC
7,200 cycles/hr15,000 cycles/hr
ConnectorDIN (DN)
DEUTSCH (DT)
IP 65
IP 69
AC
DC
350 F
300 F
Q*-03-A-***-*-**-***
SPOOL SPRING COIL VOLTAGEARRANGEMENT
A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQF- 3 POS. SPRING CENTEREDQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. AQJF- 2 POS SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN
DT- DEUTSCH
VALVE INTERFACE SEAL OPTION
03- NFPA D03 BUNA VITON
DESIGN CODE
SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)
MAXIMUM OPERATINGPRESSURE
RELATEDFLOWCAPACITY
MOUNTINGBOLTS
P,A,BPORTS
TPORT
P,A,B TPORTS
10-24 X 2”45-60 inch-#
4500 psi 2300 psi 21 gpm (DC)
16 gpm (AC)
Series Q-03directional control
valve
Specifications
Ordering Information
SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching
FrequencyIntrusionProtection
MaximumSurface Temp
50 Hz
60 Hz
99-121 VAC
108-132 VAC
10.8-13.2 VDC
30 WAC
DC
On10-20
25-45
Off15-40
10-25
AC
DC
7,200 cycles/hr15,000 cycles/hr
ConnectorDIN (DN)
DEUTSCH (DT)
IP 65
IP 69
AC
DC
350 F
300 F
Q*-03-A-***-*-**-***
SPOOL SPRING COIL VOLTAGEARRANGEMENT
A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQF- 3 POS. SPRING CENTEREDQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. AQJF- 2 POS SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN
DT- DEUTSCH
VALVE INTERFACE SEAL OPTION
03- NFPA D03 BUNAVITON
DESIGN CODE
SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)
MAXIMUM OPERATINGPRESSURE
RELATEDFLOWCAPACITY
MOUNTINGBOLTS
P,A,BPORTS
TPORT
P,A,B TPORTS
10-24 X 2”45-60 inch-#
4500 psi 2300 psi 21 gpm (DC)
16 gpm (AC)
Series Q-03directional control
valve
Specifications
Ordering Information
2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching
FrequencyIntrusionProtection
MaximumSurface Temp
50 Hz
60 Hz
99-121 VAC
108-132 VAC
10.8-13.2 VDC
30 WAC
DC
On10-20
25-45
Off15-40
10-25
AC
DC
7,200 cycles/hr15,000 cycles/hr
ConnectorDIN (DN)
DEUTSCH (DT)
IP 65
IP 69
AC
DC
350 F
300 F
Q*-03-A-***-*-**-***
SPOOL SPRING COIL VOLTAGEARRANGEMENT
A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQF- 3 POS. SPRING CENTEREDQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. AQJF- 2 POS SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN
DT- DEUTSCH
VALVE INTERFACE SEAL OPTION
03- NFPA D03 BUNAVITON
DESIGN CODE
SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)
MAXIMUM OPERATINGPRESSURE
RELATEDFLOWCAPACITY
MOUNTINGBOLTS
P,A,BPORTS
TPORT
P,A,B TPORTS
10-24 X 2”45-60 inch-#
4500 psi 2300 psi 21 gpm (DC)
16 gpm (AC)
Series Q-03directional control
valve
Specifications
Ordering Information
2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
®
©
SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching
FrequencyIntrusionProtection
MaximumSurface Temp
50 Hz
60 Hz
99-121 VAC
108-132 VAC
10.8-13.2 VDC
30 WAC
DC
On10-20
25-45
Off15-40
10-25
AC
DC
7,200 cycles/hr15,000 cycles/hr
ConnectorDIN (DN)
DEUTSCH (DT)
IP 65
IP 69
AC
DC
350 F
300 F
Q*-03-A-***-*-**-***
SPOOL SPRING COIL VOLTAGEARRANGEMENT
A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. AQJF- 2 POS. SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN
DT- DEUTSCH
VALVE INTERFACE SEAL OPTION
03- NFPA D03 BUNAVITON
DESIGN CODE
SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)
MAXIMUM OPERATING PRESSURE
RATED FLOW CAPACITY
MOUNTING BOLTS
VISCOSITY RANGE
TEMPERATURE RANGE
FLUID CLEANLINESS
WEIGHT
P,A,B PORTS
T PORT
P,A,B,T PORTS
10-24 X 2” 45-60 inch-#
60-1800 SSU -22 TO 176F Better than NAS 12
Single Solenoid 3.5 lbs
4500 psi
2300 psi
21 gpm (DC) 16 gpm (AC)
Double Solenoid 4.6 lbs
Series Q-03directional control
valve�
Specifications
Ordering Information
� 2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching
FrequencyIntrusionProtection
MaximumSurface Temp
50 Hz
60 Hz
99-121 VAC
108-132 VAC
10.8-13.2 VDC
30 WAC
DC
On10-20
25-45
Off15-40
10-25
AC
DC
7,200 cycles/hr15,000 cycles/hr
ConnectorDIN (DN)
DEUTSCH (DT)
IP 65
IP 69
AC
DC
350 F
300 F
Q*-03-A-***-*-**-***
SPOOL SPRING COIL VOLTAGEARRANGEMENT
A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. AQJF- 2 POS. SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN
DT- DEUTSCH
VALVE INTERFACE SEAL OPTION
03- NFPA D03 BUNAVITON
DESIGN CODE
SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)
MAXIMUM OPERATINGPRESSURE
RATEDFLOWCAPACITY
MOUNTINGBOLTS
VISCOSITYRANGE
TEMPERATURERANGE
FLUIDCLEANLINESS
WEIGHT
P,A,BPORTS
TPORT
P,A,B,TPORTS
10-24 X 2” 45-60 inch-#
60-1800 SSU -22 TO 176F Better than NAS 12
Single Solenoid3.5 lbs
4500 psi 2300 psi 21 gpm (DC)
16 gpm (AC)Double Solenoid4.6 lbs
Series Q-03directional control
valve�
Specifications
Ordering Information
� 2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching
FrequencyIntrusionProtection
MaximumSurface Temp
50 Hz
60 Hz
99-121 VAC
108-132 VAC
10.8-13.2 VDC
30 WAC
DC
On10-20
25-45
Off15-40
10-25
AC
DC
7,200 cycles/hr15,000 cycles/hr
ConnectorDIN (DN)
DEUTSCH (DT)
IP 65
IP 69
AC
DC
350 F
300 F
Q*-03-A-***-*-**-***
SPOOL SPRING COIL VOLTAGEARRANGEMENT
A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQF- 3 POS. SPRING CENTERED QJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. A QJF- 2 POS SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN
DT- DEUTSCH
VALVE INTERFACE SEAL OPTION
03- NFPA D03 BUNAVITON
DESIGN CODE
SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)
MAXIMUM OPERATINGPRESSURE
RELATEDFLOWCAPACITY
MOUNTINGBOLTS
P,A,BPORTS
TPORT
P,A,B TPORTS
10-24 X 2”45-60 inch-#
4500 psi 2300 psi 21 gpm (DC)
16 gpm (AC)
Series Q-03directional control
valve
Specifications
Ordering Information
2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching
FrequencyIntrusionProtection
MaximumSurface Temp
50 Hz
60 Hz
99-121 VAC
108-132 VAC
10.8-13.2 VDC
30 WAC
DC
On10-20
25-45
Off15-40
10-25
AC
DC
7,200 cycles/hr15,000 cycles/hr
ConnectorDIN (DN)
DEUTSCH (DT)
IP 65
IP 69
AC
DC
350 F
300 F
Q*-03-A-***-*-**-***
SPOOL SPRING COIL VOLTAGEARRANGEMENT
A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQF- 3 POS. SPRING CENTEREDQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. A QJF- 2 POS SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN
DT- DEUTSCH
VALVE INTERFACE SEAL OPTION
03- NFPA D03 BUNAVITON
DESIGN CODE
SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)
MAXIMUM OPERATINGPRESSURE
RELATEDFLOWCAPACITY
MOUNTINGBOLTS
P,A,BPORTS
TPORT
P,A,B TPORTS
10-24 X 2”45-60 inch-#
4500 psi 2300 psi 21 gpm (DC)
16 gpm (AC)
Series Q-03directional control
valve
Specifications
Ordering Information
2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
20/18/15Or Better
(ISO 4460)
NG06CETOP03
DT- DEUTSCH (DT04-2P)
DIN (43650A- PG11 GLAND)
B- BUNAV- VITON
Double A® Hydraulics is not related to Double A, a Division of Brown and Sharp.
Flow versus Pressure DropFlow Direction
SPOOL P TO A P TO B A TO T B TO TR-FC 3 3 5 5R-FFO1 5 3 5 5R-FTTO 1 1 4 4R-FO 6 7 6 6R-FFF 5 5 6 5RJC 2 2 3 3R-GFC - 3 3 -R-JFC 3 - - 3
Spool / Spindle Configuration
Performance Curves
�
� 2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
3 POSITION SPRING CENTERED
2 POSITION SPRING OFFSET
2 POSITION SPRING CENTERED
R/FF01
R/FTTO
R/FO
R/FFF
R/JC
R/FC
R/GFC
R/JFC
Switching Power LimitsA120 Coil
Switching Power Limits12 VDC Coils
Pressure Drop41 cSt @ 50F (187 SSU)gpm gpmgpm
R/GC
Flow versus Pressure DropFlow Direction
SPOOL P TO A P TO B A TO T B TO TR-FC 3 3 5 5R-FFO1 5 3 5 5R-FTTO 1 1 4 4R-FO 6 7 6 6R-FFF 5 5 6 5RJC 2 2 3 3R-GFC - 3 3 -R-JFC 3 - - 3
Spool / Spindle Configuration
Performance Curves
�
� 2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
3 POSITION SPRING CENTERED
2 POSITION SPRING OFFSET
2 POSITION SPRING CENTERED
R/FF01
R/FTTO
R/FO
R/FFF
R/JC
R/FC
R/GFC
R/JFC
Switching Power LimitsA120 Coil
Switching Power Limits12 VDC Coils
Pressure Drop41 cSt @ 50F (187 SSU)gpm gpmgpm
R/GC
3 POSITION SPRING CENTERED 2 POSITION SPRING OFFSET
2 POSITION SPRING CENTERED
R/GFC R/GFFF
R/JFC
A B
A B
P T
P T
A B
A B
P T
P Ta
a
b
Switching Power LimitsA120 Coil
Switching Power Limits12 VDC Coils
Pressure Drop41 cSt @ 50F (187 SSU)
4000
150
125
100
75
50
5 10 15 20 25
25
3000
1000
5 10 15
2000
psi
psi
gpmgpm
R/FTTO R/FO
R/FFO1
gpm
psi
®
Flow versus Pressure Drop Flow Direction
SPOOL P TO A P TO B A TO T B TO T R-FC 3 3 5 5R-FFO1 5 3 5 5R-FTTO 1 1 4 4R-FO 6 7 6 6R-FFF 5 5 6 5RJC 2 2 3 3R-GFC - 3 3 -R-JFC 3 - - 3
Performance Curves
� www.doubleahydraulics.com
2 POSITION SPRING CENTERED
R/FF01
R/FTTO
R/FO
R/FFF
R/JC
R/GFC
R/JFC
R/GC
2014 Double A Hydraulics All rights reserved.
SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching
FrequencyIntrusionProtection
MaximumSurface Temp
50 Hz
60 Hz
99-121 VAC
108-132 VAC
10.8-13.2 VDC
30 WAC
DC
On10-20
25-45
Off15-40
10-25
AC
DC
7,200 cycles/hr15,000 cycles/hr
ConnectorDIN (DN)
DEUTSCH (DT)
IP 65
IP 69
AC
DC
350 F
300 F
Q*-03-A-***-*-**-***
SPOOL SPRING COIL VOLTAGEARRANGEMENT
A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQF- 3 POS. SPRING CENTEREDQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. AQJF- 2 POS SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN
DT- DEUTSCH
VALVE INTERFACE SEAL OPTION
03- NFPA D03 BUNAVITON
DESIGN CODE
SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)
MAXIMUM OPERATINGPRESSURE
RELATEDFLOWCAPACITY
MOUNTINGBOLTS
P,A,BPORTS
TPORT
P,A,B TPORTS
10-24 X 2”45-60 inch-#
4500 psi 2300 psi 21 gpm (DC)
16 gpm (AC)
Series Q-03directional control
valve
Specifications
Ordering Information
www.doubleahydraulics.com
R/FCR/JCR/GCR/FFFR/GFCR/JFCR/GFFFR/JFFF
4000
3000
1000
2000
5 10 15 20
R/FCR/GFCR/JFC
R/FOR/FTTO
R/FFFR/GFFR/JFF
R/JCR/GCR/GOX
Flow versus Pressure DropFlow Direction
SPOOL P TO A P TO B A TO T B TO TR-FC 3 3 5 5R-FFO1 5 3 5 5R-FTTO 1 1 4 4R-FO 6 7 6 6R-FFF 5 5 6 5RJC 2 2 3 3R-GFC - 3 3 -R-JFC 3 - - 3
Spool / Spindle Configuration
Performance Curves
�
� 2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
3 POSITION SPRING CENTERED 2 POSITION SPRING OFFSET
2 POSITION SPRING CENTERED
R/FF01
R/FTTO
R/FO
R/FFF
R/JC
R/FC
R/GFC
R/JFC
Switching Power LimitsA120 Coil
Switching Power Limits12 VDC Coils
Pressure Drop41 cSt @ 50F (187 SSU)gpm gpmgpm
R/GC
Flow versus Pressure DropFlow Direction
SPOOL P TO A P TO B A TO T B TO TR-FC 3 3 5 5R-FFO1 5 3 5 5R-FTTO 1 1 4 4R-FO 6 7 6 6R-FFF 5 5 6 5RJC 2 2 3 3R-GFC - 3 3 -R-JFC 3 - - 3
Spool / Spindle Configuration
Performance Curves
�
� 2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
3 POSITION SPRING CENTERED 2 POSITION SPRING OFFSET
2 POSITION SPRING CENTERED
R/FF01
R/FTTO
R/FO
R/FFF
R/JC
R/FC
R/GFC
R/JFC
Switching Power LimitsA120 Coil
Switching Power Limits12 VDC Coils
Pressure Drop41 cSt @ 50F (187 SSU)gpm gpmgpm
R/GC
P T
b
b
A B
A B
a
a
R/FC
R/FF01
P T
P T
P T
b
b
b
a
a
a
A B
A B
A B
R/FTTO
R/FO
R/FFF
R/GOX
R/GC
A B
A B
P T
P T
a
b
R/JFFF
a
R/FCR/FTTOR/FOR/FFFR/GOXR/GCR/JCR/GFCRJFCR/JFFFR/GFFF
3165522-3-5
31755223-5-
54663333-6-
5465533-3-5
R/JCR/GC
R/GOX
R/JC
A B
bP T
P T
© 2018 Double A Hydraulics All rights reserved. Double A® Hydraulics is not related to Double A, a Division of Brown and Sharp.
Dimensions DIN CONNECTOR VALVE
DT CONNECTOR VALVE
�
� ®
SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching
FrequencyIntrusionProtection
MaximumSurface Temp
50 Hz
60 Hz
99-121 VAC
108-132 VAC
10.8-13.2 VDC
30 WAC
DC
On10-20
25-45
Off15-40
10-25
AC
DC
7,200 cycles/hr15,000 cycles/hr
ConnectorDIN (DN)
DEUTSCH (DT)
IP 65
IP 69
AC
DC
350 F
300 F
Q*-03-A-***-*-**-***
SPOOL SPRING COIL VOLTAGEARRANGEMENT
A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQF- 3 POS. SPRING CENTEREDQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. AQJF- 2 POS SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN
DT- DEUTSCH
VALVE INTERFACE SEAL OPTION
03- NFPA D03 BUNAVITON
DESIGN CODE
SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)
MAXIMUM OPERATINGPRESSURE
RELATEDFLOWCAPACITY
MOUNTINGBOLTS
P,A,BPORTS
TPORT
P,A,B TPORTS
10-24 X 2”45-60 inch-#
4500 psi 2300 psi 21 gpm (DC)
16 gpm (AC)
Series Q-03directional control
valve
Specifications
Ordering Information
© 8
3.30
1.28
0.59
1.22
0.33
1.48
1.99 DC
2.83 DC
8.39 DC
2.72
0.59
1.22 1.28
0.33 0.33
1.99 DC2.07 AC
2.87 AC
8.46 AC
2.83 DC
8.39 DC
2.72
1.48
2.07 AC
2.87 AC
8.46 AC
0.33
2.51
1.81
0.91
1.81
0.91
Double A® Hydraulics is not related to Double A, a Division of Brown and Sharp.