series q-03 directional control valve · a q - 3 pos. sp ring c ent d qj- 2 p os . spr ng ffset, l...

4
series Q-03 directional control valve 536 TOWNSHIP LINE ROAD FLUID TECHNOLOGY ANNEX BLUE BELL, PENNSYLVANIA 19422 Tel: 215.643.0617 Fax: 216.643.4017 [email protected] www.doubleahydraulics.com www.doubleahydraulics.com 4500 psi, 21 Gpm max wet armature solenoid operated ® four land spool © 2018 Double A Hydraulics All rights reserved. Double A ® Hydraulics is not related to Double A, a Division of Brown and Sharp.

Upload: others

Post on 27-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: series Q-03 directional control valve · A Q - 3 POS. SP RING C ENT D QJ- 2 P OS . SPR NG FFSET, L B ELECTR ICAL C ONNECT QGF- 2 P OS . SP RING C NT D, L A QJF -2 P OSP RING C ENT

–––––

series Q-03 directional control

valve

4500 psi, 21 Gpm max

wet armature solenoid operated

536 TOWNSHIP LINE ROAD FLUID TECHNOLOGY ANNEX BLUE BELL, PENNSYLVANIA 19422 Tel: 215.643.0617 Fax: 216.643.4017 [email protected] www.doubleahydraulics.com

www.doubleahydraulics.com

–––––

series Q-03 directional control

valve

4500 psi, 21 Gpm max

wet armature solenoid operated

536 TOWNSHIP LINE ROADFLUID TECHNOLOGY ANNEXBLUE BELL, PENNSYLVANIA 19422Tel: 215.643.0617Fax: [email protected]

2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com

®

four land spool

© 2018 Double A Hydraulics All rights reserved. Double A® Hydraulics is not related to Double A, a Division of Brown and Sharp.

Page 2: series Q-03 directional control valve · A Q - 3 POS. SP RING C ENT D QJ- 2 P OS . SPR NG FFSET, L B ELECTR ICAL C ONNECT QGF- 2 P OS . SP RING C NT D, L A QJF -2 P OSP RING C ENT

SOLENOID COILS 120 VAC Nominal 12 VDC Response Time (ms) Switching

Frequency Intrusion Protection

Maximum Surface Temp

50 Hz 60 Hz

99-121 VAC 108-132 VAC

10.8-13.2 VDC

30 W AC DC

On 10-20

25-45

Off 15-40

10-25

AC

DC

7,200 cycles/hr 15,000 cycles/hr

Connector DIN (DN) DEUTSCH (DT)

IP 65 IP 69

AC DC

350 F 300 F

Q*-03-A-***-*-**-***

SPOOL SPRING COIL VOLTAGE ARRANGEMENT A120- 120 VAC 50/60 HZ QF- 3 POS. SPRING CENTERED D12- 12VDC

QG- 2 POS. SPRING OFFSET, SOL. A QF- 3 POS. SPRING CENTERED QJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTION QGF- 2 POS. SPRING CENTERED, SOL. A QJF- 2 POS SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN

DT- DEUTSCH

VALVE INTERFACE SEAL OPTION

03- NFPA D03 BUNA VITON

DESIGN CODE SPOOL FUNCTION AND TYPE

(SEE CHART ON NEXT PAGE)

MAXIMUM OPERATING PRESSURE

RELATED FLOW CAPACITY

MOUNTING BOLTS

P,A,B PORTS

T PORT

P,A,B T PORTS

10-24 X 2” 45-60 inch-#

4500 psi

2300 psi

21 gpm (DC)

16 gpm (AC)

Series Q-03 directional control valve

Specifications

Ordering Information

2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com

SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching

FrequencyIntrusionProtection

MaximumSurface Temp

50 Hz

60 Hz

99-121 VAC

108-132 VAC

10.8-13.2 VDC

30 WAC

DC

On10-20

25-45

Off15-40

10-25

AC

DC

7,200 cycles/hr15,000 cycles/hr

ConnectorDIN (DN)

DEUTSCH (DT)

IP 65

IP 69

AC

DC

350 F

300 F

Q*-03-A-***-*-**-***

SPOOL SPRING COIL VOLTAGEARRANGEMENT

A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQF- 3 POS. SPRING CENTEREDQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. AQJF- 2 POS SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN

DT- DEUTSCH

VALVE INTERFACE SEAL OPTION

03- NFPA D03 BUNAVITON

DESIGN CODE

SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)

MAXIMUM OPERATINGPRESSURE

RELATEDFLOWCAPACITY

MOUNTINGBOLTS

P,A,BPORTS

TPORT

P,A,B TPORTS

10-24 X 2”45-60 inch-#

4500 psi 2300 psi 21 gpm (DC)

16 gpm (AC)

Series Q-03directional control

valve

Specifications

Ordering Information

2018 Double A Hydraulics All rights reserved. www.doubleahydraulics.com

SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching

FrequencyIntrusionProtection

MaximumSurface Temp

50 Hz

60 Hz

99-121 VAC

108-132 VAC

10.8-13.2 VDC

30 WAC

DC

On10-20

25-45

Off15-40

10-25

AC

DC

7,200 cycles/hr15,000 cycles/hr

ConnectorDIN (DN)

DEUTSCH (DT)

IP 65

IP 69

AC

DC

350 F

300 F

Q*-03-A-***-*-**-***

SPOOL SPRING COIL VOLTAGEARRANGEMENT

A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQF- 3 POS. SPRING CENTEREDQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. AQJF- 2 POS SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN

DT- DEUTSCH

VALVE INTERFACE SEAL OPTION

03- NFPA D03 BUNA VITON

DESIGN CODE

SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)

MAXIMUM OPERATINGPRESSURE

RELATEDFLOWCAPACITY

MOUNTINGBOLTS

P,A,BPORTS

TPORT

P,A,B TPORTS

10-24 X 2”45-60 inch-#

4500 psi 2300 psi 21 gpm (DC)

16 gpm (AC)

Series Q-03directional control

valve

Specifications

Ordering Information

SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching

FrequencyIntrusionProtection

MaximumSurface Temp

50 Hz

60 Hz

99-121 VAC

108-132 VAC

10.8-13.2 VDC

30 WAC

DC

On10-20

25-45

Off15-40

10-25

AC

DC

7,200 cycles/hr15,000 cycles/hr

ConnectorDIN (DN)

DEUTSCH (DT)

IP 65

IP 69

AC

DC

350 F

300 F

Q*-03-A-***-*-**-***

SPOOL SPRING COIL VOLTAGEARRANGEMENT

A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQF- 3 POS. SPRING CENTEREDQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. AQJF- 2 POS SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN

DT- DEUTSCH

VALVE INTERFACE SEAL OPTION

03- NFPA D03 BUNAVITON

DESIGN CODE

SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)

MAXIMUM OPERATINGPRESSURE

RELATEDFLOWCAPACITY

MOUNTINGBOLTS

P,A,BPORTS

TPORT

P,A,B TPORTS

10-24 X 2”45-60 inch-#

4500 psi 2300 psi 21 gpm (DC)

16 gpm (AC)

Series Q-03directional control

valve

Specifications

Ordering Information

2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com

SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching

FrequencyIntrusionProtection

MaximumSurface Temp

50 Hz

60 Hz

99-121 VAC

108-132 VAC

10.8-13.2 VDC

30 WAC

DC

On10-20

25-45

Off15-40

10-25

AC

DC

7,200 cycles/hr15,000 cycles/hr

ConnectorDIN (DN)

DEUTSCH (DT)

IP 65

IP 69

AC

DC

350 F

300 F

Q*-03-A-***-*-**-***

SPOOL SPRING COIL VOLTAGEARRANGEMENT

A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQF- 3 POS. SPRING CENTEREDQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. AQJF- 2 POS SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN

DT- DEUTSCH

VALVE INTERFACE SEAL OPTION

03- NFPA D03 BUNAVITON

DESIGN CODE

SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)

MAXIMUM OPERATINGPRESSURE

RELATEDFLOWCAPACITY

MOUNTINGBOLTS

P,A,BPORTS

TPORT

P,A,B TPORTS

10-24 X 2”45-60 inch-#

4500 psi 2300 psi 21 gpm (DC)

16 gpm (AC)

Series Q-03directional control

valve

Specifications

Ordering Information

2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com

®

©

SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching

FrequencyIntrusionProtection

MaximumSurface Temp

50 Hz

60 Hz

99-121 VAC

108-132 VAC

10.8-13.2 VDC

30 WAC

DC

On10-20

25-45

Off15-40

10-25

AC

DC

7,200 cycles/hr15,000 cycles/hr

ConnectorDIN (DN)

DEUTSCH (DT)

IP 65

IP 69

AC

DC

350 F

300 F

Q*-03-A-***-*-**-***

SPOOL SPRING COIL VOLTAGEARRANGEMENT

A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. AQJF- 2 POS. SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN

DT- DEUTSCH

VALVE INTERFACE SEAL OPTION

03- NFPA D03 BUNAVITON

DESIGN CODE

SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)

MAXIMUM OPERATING PRESSURE

RATED FLOW CAPACITY

MOUNTING BOLTS

VISCOSITY RANGE

TEMPERATURE RANGE

FLUID CLEANLINESS

WEIGHT

P,A,B PORTS

T PORT

P,A,B,T PORTS

10-24 X 2” 45-60 inch-#

60-1800 SSU -22 TO 176F Better than NAS 12

Single Solenoid 3.5 lbs

4500 psi

2300 psi

21 gpm (DC) 16 gpm (AC)

Double Solenoid 4.6 lbs

Series Q-03directional control

valve�

Specifications

Ordering Information

� 2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com

SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching

FrequencyIntrusionProtection

MaximumSurface Temp

50 Hz

60 Hz

99-121 VAC

108-132 VAC

10.8-13.2 VDC

30 WAC

DC

On10-20

25-45

Off15-40

10-25

AC

DC

7,200 cycles/hr15,000 cycles/hr

ConnectorDIN (DN)

DEUTSCH (DT)

IP 65

IP 69

AC

DC

350 F

300 F

Q*-03-A-***-*-**-***

SPOOL SPRING COIL VOLTAGEARRANGEMENT

A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. AQJF- 2 POS. SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN

DT- DEUTSCH

VALVE INTERFACE SEAL OPTION

03- NFPA D03 BUNAVITON

DESIGN CODE

SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)

MAXIMUM OPERATINGPRESSURE

RATEDFLOWCAPACITY

MOUNTINGBOLTS

VISCOSITYRANGE

TEMPERATURERANGE

FLUIDCLEANLINESS

WEIGHT

P,A,BPORTS

TPORT

P,A,B,TPORTS

10-24 X 2” 45-60 inch-#

60-1800 SSU -22 TO 176F Better than NAS 12

Single Solenoid3.5 lbs

4500 psi 2300 psi 21 gpm (DC)

16 gpm (AC)Double Solenoid4.6 lbs

Series Q-03directional control

valve�

Specifications

Ordering Information

� 2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com

SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching

FrequencyIntrusionProtection

MaximumSurface Temp

50 Hz

60 Hz

99-121 VAC

108-132 VAC

10.8-13.2 VDC

30 WAC

DC

On10-20

25-45

Off15-40

10-25

AC

DC

7,200 cycles/hr15,000 cycles/hr

ConnectorDIN (DN)

DEUTSCH (DT)

IP 65

IP 69

AC

DC

350 F

300 F

Q*-03-A-***-*-**-***

SPOOL SPRING COIL VOLTAGEARRANGEMENT

A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQF- 3 POS. SPRING CENTERED QJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. A QJF- 2 POS SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN

DT- DEUTSCH

VALVE INTERFACE SEAL OPTION

03- NFPA D03 BUNAVITON

DESIGN CODE

SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)

MAXIMUM OPERATINGPRESSURE

RELATEDFLOWCAPACITY

MOUNTINGBOLTS

P,A,BPORTS

TPORT

P,A,B TPORTS

10-24 X 2”45-60 inch-#

4500 psi 2300 psi 21 gpm (DC)

16 gpm (AC)

Series Q-03directional control

valve

Specifications

Ordering Information

2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com

SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching

FrequencyIntrusionProtection

MaximumSurface Temp

50 Hz

60 Hz

99-121 VAC

108-132 VAC

10.8-13.2 VDC

30 WAC

DC

On10-20

25-45

Off15-40

10-25

AC

DC

7,200 cycles/hr15,000 cycles/hr

ConnectorDIN (DN)

DEUTSCH (DT)

IP 65

IP 69

AC

DC

350 F

300 F

Q*-03-A-***-*-**-***

SPOOL SPRING COIL VOLTAGEARRANGEMENT

A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQF- 3 POS. SPRING CENTEREDQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. A QJF- 2 POS SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN

DT- DEUTSCH

VALVE INTERFACE SEAL OPTION

03- NFPA D03 BUNAVITON

DESIGN CODE

SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)

MAXIMUM OPERATINGPRESSURE

RELATEDFLOWCAPACITY

MOUNTINGBOLTS

P,A,BPORTS

TPORT

P,A,B TPORTS

10-24 X 2”45-60 inch-#

4500 psi 2300 psi 21 gpm (DC)

16 gpm (AC)

Series Q-03directional control

valve

Specifications

Ordering Information

2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com

20/18/15Or Better

(ISO 4460)

NG06CETOP03

DT- DEUTSCH (DT04-2P)

DIN (43650A- PG11 GLAND)

B- BUNAV- VITON

Double A® Hydraulics is not related to Double A, a Division of Brown and Sharp.

Page 3: series Q-03 directional control valve · A Q - 3 POS. SP RING C ENT D QJ- 2 P OS . SPR NG FFSET, L B ELECTR ICAL C ONNECT QGF- 2 P OS . SP RING C NT D, L A QJF -2 P OSP RING C ENT

Flow versus Pressure DropFlow Direction

SPOOL P TO A P TO B A TO T B TO TR-FC 3 3 5 5R-FFO1 5 3 5 5R-FTTO 1 1 4 4R-FO 6 7 6 6R-FFF 5 5 6 5RJC 2 2 3 3R-GFC - 3 3 -R-JFC 3 - - 3

Spool / Spindle Configuration

Performance Curves

� 2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com

3 POSITION SPRING CENTERED

2 POSITION SPRING OFFSET

2 POSITION SPRING CENTERED

R/FF01

R/FTTO

R/FO

R/FFF

R/JC

R/FC

R/GFC

R/JFC

Switching Power LimitsA120 Coil

Switching Power Limits12 VDC Coils

Pressure Drop41 cSt @ 50F (187 SSU)gpm gpmgpm

R/GC

Flow versus Pressure DropFlow Direction

SPOOL P TO A P TO B A TO T B TO TR-FC 3 3 5 5R-FFO1 5 3 5 5R-FTTO 1 1 4 4R-FO 6 7 6 6R-FFF 5 5 6 5RJC 2 2 3 3R-GFC - 3 3 -R-JFC 3 - - 3

Spool / Spindle Configuration

Performance Curves

� 2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com

3 POSITION SPRING CENTERED

2 POSITION SPRING OFFSET

2 POSITION SPRING CENTERED

R/FF01

R/FTTO

R/FO

R/FFF

R/JC

R/FC

R/GFC

R/JFC

Switching Power LimitsA120 Coil

Switching Power Limits12 VDC Coils

Pressure Drop41 cSt @ 50F (187 SSU)gpm gpmgpm

R/GC

3 POSITION SPRING CENTERED 2 POSITION SPRING OFFSET

2 POSITION SPRING CENTERED

R/GFC R/GFFF

R/JFC

A B

A B

P T

P T

A B

A B

P T

P Ta

a

b

Switching Power LimitsA120 Coil

Switching Power Limits12 VDC Coils

Pressure Drop41 cSt @ 50F (187 SSU)

4000

150

125

100

75

50

5 10 15 20 25

25

3000

1000

5 10 15

2000

psi

psi

gpmgpm

R/FTTO R/FO

R/FFO1

gpm

psi

®

Flow versus Pressure Drop Flow Direction

SPOOL P TO A P TO B A TO T B TO T R-FC 3 3 5 5R-FFO1 5 3 5 5R-FTTO 1 1 4 4R-FO 6 7 6 6R-FFF 5 5 6 5RJC 2 2 3 3R-GFC - 3 3 -R-JFC 3 - - 3

Performance Curves

� www.doubleahydraulics.com

2 POSITION SPRING CENTERED

R/FF01

R/FTTO

R/FO

R/FFF

R/JC

R/GFC

R/JFC

R/GC

2014 Double A Hydraulics All rights reserved.

SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching

FrequencyIntrusionProtection

MaximumSurface Temp

50 Hz

60 Hz

99-121 VAC

108-132 VAC

10.8-13.2 VDC

30 WAC

DC

On10-20

25-45

Off15-40

10-25

AC

DC

7,200 cycles/hr15,000 cycles/hr

ConnectorDIN (DN)

DEUTSCH (DT)

IP 65

IP 69

AC

DC

350 F

300 F

Q*-03-A-***-*-**-***

SPOOL SPRING COIL VOLTAGEARRANGEMENT

A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQF- 3 POS. SPRING CENTEREDQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. AQJF- 2 POS SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN

DT- DEUTSCH

VALVE INTERFACE SEAL OPTION

03- NFPA D03 BUNAVITON

DESIGN CODE

SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)

MAXIMUM OPERATINGPRESSURE

RELATEDFLOWCAPACITY

MOUNTINGBOLTS

P,A,BPORTS

TPORT

P,A,B TPORTS

10-24 X 2”45-60 inch-#

4500 psi 2300 psi 21 gpm (DC)

16 gpm (AC)

Series Q-03directional control

valve

Specifications

Ordering Information

www.doubleahydraulics.com

R/FCR/JCR/GCR/FFFR/GFCR/JFCR/GFFFR/JFFF

4000

3000

1000

2000

5 10 15 20

R/FCR/GFCR/JFC

R/FOR/FTTO

R/FFFR/GFFR/JFF

R/JCR/GCR/GOX

Flow versus Pressure DropFlow Direction

SPOOL P TO A P TO B A TO T B TO TR-FC 3 3 5 5R-FFO1 5 3 5 5R-FTTO 1 1 4 4R-FO 6 7 6 6R-FFF 5 5 6 5RJC 2 2 3 3R-GFC - 3 3 -R-JFC 3 - - 3

Spool / Spindle Configuration

Performance Curves

� 2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com

3 POSITION SPRING CENTERED 2 POSITION SPRING OFFSET

2 POSITION SPRING CENTERED

R/FF01

R/FTTO

R/FO

R/FFF

R/JC

R/FC

R/GFC

R/JFC

Switching Power LimitsA120 Coil

Switching Power Limits12 VDC Coils

Pressure Drop41 cSt @ 50F (187 SSU)gpm gpmgpm

R/GC

Flow versus Pressure DropFlow Direction

SPOOL P TO A P TO B A TO T B TO TR-FC 3 3 5 5R-FFO1 5 3 5 5R-FTTO 1 1 4 4R-FO 6 7 6 6R-FFF 5 5 6 5RJC 2 2 3 3R-GFC - 3 3 -R-JFC 3 - - 3

Spool / Spindle Configuration

Performance Curves

� 2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com

3 POSITION SPRING CENTERED 2 POSITION SPRING OFFSET

2 POSITION SPRING CENTERED

R/FF01

R/FTTO

R/FO

R/FFF

R/JC

R/FC

R/GFC

R/JFC

Switching Power LimitsA120 Coil

Switching Power Limits12 VDC Coils

Pressure Drop41 cSt @ 50F (187 SSU)gpm gpmgpm

R/GC

P T

b

b

A B

A B

a

a

R/FC

R/FF01

P T

P T

P T

b

b

b

a

a

a

A B

A B

A B

R/FTTO

R/FO

R/FFF

R/GOX

R/GC

A B

A B

P T

P T

a

b

R/JFFF

a

R/FCR/FTTOR/FOR/FFFR/GOXR/GCR/JCR/GFCRJFCR/JFFFR/GFFF

3165522-3-5

31755223-5-

54663333-6-

5465533-3-5

R/JCR/GC

R/GOX

R/JC

A B

bP T

P T

© 2018 Double A Hydraulics All rights reserved. Double A® Hydraulics is not related to Double A, a Division of Brown and Sharp.

Page 4: series Q-03 directional control valve · A Q - 3 POS. SP RING C ENT D QJ- 2 P OS . SPR NG FFSET, L B ELECTR ICAL C ONNECT QGF- 2 P OS . SP RING C NT D, L A QJF -2 P OSP RING C ENT

Dimensions DIN CONNECTOR VALVE

DT CONNECTOR VALVE

� ®

SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching

FrequencyIntrusionProtection

MaximumSurface Temp

50 Hz

60 Hz

99-121 VAC

108-132 VAC

10.8-13.2 VDC

30 WAC

DC

On10-20

25-45

Off15-40

10-25

AC

DC

7,200 cycles/hr15,000 cycles/hr

ConnectorDIN (DN)

DEUTSCH (DT)

IP 65

IP 69

AC

DC

350 F

300 F

Q*-03-A-***-*-**-***

SPOOL SPRING COIL VOLTAGEARRANGEMENT

A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQF- 3 POS. SPRING CENTEREDQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. AQJF- 2 POS SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN

DT- DEUTSCH

VALVE INTERFACE SEAL OPTION

03- NFPA D03 BUNAVITON

DESIGN CODE

SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)

MAXIMUM OPERATINGPRESSURE

RELATEDFLOWCAPACITY

MOUNTINGBOLTS

P,A,BPORTS

TPORT

P,A,B TPORTS

10-24 X 2”45-60 inch-#

4500 psi 2300 psi 21 gpm (DC)

16 gpm (AC)

Series Q-03directional control

valve

Specifications

Ordering Information

© 8

3.30

1.28

0.59

1.22

0.33

1.48

1.99 DC

2.83 DC

8.39 DC

2.72

0.59

1.22 1.28

0.33 0.33

1.99 DC2.07 AC

2.87 AC

8.46 AC

2.83 DC

8.39 DC

2.72

1.48

2.07 AC

2.87 AC

8.46 AC

0.33

2.51

1.81

0.91

1.81

0.91

Double A® Hydraulics is not related to Double A, a Division of Brown and Sharp.