sentry 6140 tip flow monitor - welcome to … · step 2: choose tip sensor kit ... 75-30100...

2
98-01449-R3 © TeeJet Technologies 2014 SENTRY 6140 TIP FLOW MONITOR Identifying Plugged Spray Tips Has Never Been Easier Plugged or partially blocked spray tips can have a significant impact on the quality of your spraying job. Streaks in the field caused by misapplication can result in yield reductions, increased weed pressure and the need to re- apply - all of which can be costly. The Sentry 6140 Tip Flow Monitor provides a simple, reliable solution to this age-old problem. Flow sensors mounted at each spray tip location monitor the flow through the tip and provide instantaneous feedback to the operator should a tip become clogged. By eliminating the need to detect plugged tips visually from the cab, operators can cover more acres in a day, and know, with confidence, that their spray tips are operating properly. Sentry 6140 Tip Flow Monitor Individually monitor flow performance from every spray tip on your boom. Sentry 6140 utilizes a compact flow meter integrated into each nozzle body. Flow meter detects flow variation caused by clogs, nozzle damage or loss, or upstream flow restrictions. System can monitor up to 75 spray nozzles simultaneously. Error is indicated by audible alarm, display notification and illuminated LED at the affected nozzle. Flow meters rated from 0.1-2.5 GPM (0.4-9.5 l/min) and maximum pressure of 150 PSI (10 bar). Part Number Description Step 1: Choose a Sentry 6140 Basic Kit 90-02860 Kit, Basic Sentry 6140, Multiple Sections (1-15) Includes: Sentry Console Kit, Tip Flow Monitor Kit, Boom Sense 1-15 harness, Power Cable Supports: Sprayers and fertilizer applicators with multiple boom section valves (See items 1, 2, & 3 in system diagrams) 90-02889 Kit, Basic Sentry 6140, Single Section Includes: Sentry Console Kit, Tip Flow Monitor Kit, Boom Sense Single harness, Power cable Supports: Fertilizer applicators and planters with single or no boom section valves (See items 1, 2, & 3 in system diagrams) Step 2: Choose Tip Sensor Kit 90-02861 Kit, Dual Flow Sensor Includes: (2) flowmeters and (1) dual tip sensor interface 90-02862 Kit, Single Flow Sensor Includes: (1) flowmeter and (1) single tip sensor interface Step 3: Choose Extension Cables 45-05857 Cable, 3’/0.9m Sensor Extension 45-05858 Cable, 6’/1.8m Sensor Extension 45-05859 Cable, 12’/3.7m Sensor Extension 45-05864 Cable, 35’/10.6m Sensor Extension 45-05900 Cable, 5’/1.5m Console Extension 45-05901 Cable, 10’/3.0m Console Extension 45-05902 Cable, 20’/6.0m Console Extension 45-05903 Cable, 40’/12.0m Console Extension Part Number Description 90-02871 Kit, Sentry 6140 Console Includes: Console and RAM mount (See items 1 in system diagrams) 90-02852 Kit, Tip Flow Monitor Includes: Terminators (Male/Female), TFMI harness, TFMI and BIM Interfaces (See items 2 in system diagrams) 401-0016 Cable Power, 1 Lead, 2 ‘/0.6m (MTAC group) 45-05855 Terminator, Female 45-05856 Terminator, Male 45-10142 Harness, Boom Interface Module 45-10147 Harness, BIM, Hagie DTS-08 & DTS-10 45-10148 Harness, Tip Flow Monitor Interface 45-10159 Harness, BIM Single Boom Status, With Switch 45-10153 Harness, BIM, Hagie STS-10, 2006-2009 57-00122 Flowmeter Assy., Tip Flow 57-00123 Gasket, Tip Flow Meter 65-05241 Kit, Sentry Ram Mount W/ Suction Cup 75-30100 Console, Sentry 6140 Tip Flow Monitor 78-05091 Boom Interface Module 78-05101 Interface, Tip Flow Monitor 78-05104 Interface, Single Tip Sensor 78-05105 Interface, Dual Tip Sensor Components SENTRY 6140 TIP FLOW MONITOR Sentry 6140 System Ordering Information

Upload: vuongxuyen

Post on 11-Apr-2018

218 views

Category:

Documents


1 download

TRANSCRIPT

98-01449-R3 © TeeJet Technologies 2014

SENTRY 6140T I P F L O W M O N I T O R

Identifying Plugged Spray Tips Has Never Been Easier

Plugged or partially blocked spray tips can have a significant impact on the quality of your spraying job. Streaks in the field caused by misapplication can result in yield reductions, increased weed pressure and the need to re-apply - all of which can be costly. The Sentry 6140 Tip Flow Monitor provides a simple, reliable solution to this age-old problem. Flow sensors mounted at each spray tip location monitor the flow through the tip and provide instantaneous feedback to the operator should a tip become clogged. By eliminating the need to detect plugged tips visually from the cab, operators can cover more acres in a day, and know, with confidence, that their spray tips are operating properly.

Sentry 6140 Tip Flow Monitor

• Individually monitor flow performance from every spray tip on your boom.• Sentry 6140 utilizes a compact flow meter integrated into each nozzle body.• Flow meter detects flow variation caused by clogs, nozzle damage or

loss, or upstream flow restrictions.• System can monitor up to 75 spray nozzles simultaneously.• Error is indicated by audible alarm, display notification and illuminated

LED at the affected nozzle.• Flow meters rated from 0.1-2.5 GPM (0.4-9.5 l/min) and maximum

pressure of 150 PSI (10 bar).

Part Number DescriptionStep 1: Choose a Sentry 6140 Basic Kit90-02860 Kit, Basic Sentry 6140, Multiple Sections (1-15)

Includes: Sentry Console Kit, Tip Flow Monitor Kit, Boom Sense 1-15 harness, Power Cable Supports: Sprayers and fertilizer applicators with multiple boom section valves (See items 1, 2, & 3 in system diagrams)

90-02889 Kit, Basic Sentry 6140, Single Section Includes: Sentry Console Kit, Tip Flow Monitor Kit, Boom Sense Single harness, Power cable Supports: Fertilizer applicators and planters with single or no boom section valves (See items 1, 2, & 3 in system diagrams)

Step 2: Choose Tip Sensor Kit90-02861 Kit, Dual Flow Sensor

Includes: (2) flowmeters and (1) dual tip sensor interface 90-02862 Kit, Single Flow Sensor

Includes: (1) flowmeter and (1) single tip sensor interface

Step 3: Choose Extension Cables45-05857 Cable, 3’/0.9m Sensor Extension 45-05858 Cable, 6’/1.8m Sensor Extension 45-05859 Cable, 12’/3.7m Sensor Extension 45-05864 Cable, 35’/10.6m Sensor Extension 45-05900 Cable, 5’/1.5m Console Extension 45-05901 Cable, 10’/3.0m Console Extension 45-05902 Cable, 20’/6.0m Console Extension 45-05903 Cable, 40’/12.0m Console Extension

Part Number Description90-02871 Kit, Sentry 6140 Console

Includes: Console and RAM mount (See items 1 in system diagrams)

90-02852 Kit, Tip Flow Monitor Includes: Terminators (Male/Female), TFMI harness, TFMI and BIM Interfaces (See items 2 in system diagrams)

401-0016 Cable Power, 1 Lead, 2 ‘/0.6m (MTAC group) 45-05855 Terminator, Female 45-05856 Terminator, Male 45-10142 Harness, Boom Interface Module 45-10147 Harness, BIM, Hagie DTS-08 & DTS-10 45-10148 Harness, Tip Flow Monitor Interface 45-10159 Harness, BIM Single Boom Status, With Switch 45-10153 Harness, BIM, Hagie STS-10, 2006-2009 57-00122 Flowmeter Assy., Tip Flow 57-00123 Gasket, Tip Flow Meter 65-05241 Kit, Sentry Ram Mount W/ Suction Cup 75-30100 Console, Sentry 6140 Tip Flow Monitor 78-05091 Boom Interface Module 78-05101 Interface, Tip Flow Monitor 78-05104 Interface, Single Tip Sensor 78-05105 Interface, Dual Tip Sensor

Components

SENTRY 6140 TIP FLOW MONITOR

Sentry 6140 System Ordering Information

2 www.teejet.com www.teejet.com 3

More About Sentry 6140

The turbine style flow meter used with the Sentry 6140 Tip Flow Monitor is compact, reliable and proven. The threaded connection allows the sensor to be added onto a wide range of standard TeeJet single and multiple outlet nozzle bodies. ChemSaver® diaphragm check valves remain in place to provide positive spray tip shutoff. Ample clearance inside the flow meter means minimal flow restriction and generous free passage for particles contained in the spray solution. Long wearing materials are used in bearing surfaces to ensure a consistent flow reading. The flow meter sensor is mounted externally to prevent direct contact with the spray solution for long-term reliability.

F L O W M E T E R C R O S S S E C T I O N

For Sprayers and Applicators with Multiple Boom Sections

Battery Adapter 3

401-0016

TFMI Harness 2

45-10148

78-05101

StartTerminator Female 2

45-05855

45-05900: 5' / 1.5m45-05901: 10' / 3.0m45-05902: 20' / 6.0m45-05903: 40' / 12.0m

75-30100

RAM Mount 1

65-05241

Sentry 6140Console Kit

90-02871

Console ExtensionCable

BIM Harness 3

45-10142

Boom InterfaceModule (BIM) 2

78-05091

45-05857: 3' / 0.9m45-05858: 6' / 1.8m45-05859: 12' / 3.7m45-05864: 35' / 10.6m

Extension CableSensor

Tip SensorInterface78-05104

NozzleFlowmeter

Dual Tip SensorInterface

EndTerminator Male 2

45-05856

Tip Flow Monitor

Interface 2

57-00122

78-05105

Sentry 6140Console 1

Sentry 6140Console 1

75-30100

Sentry 6140Console Kit

90-02871

RAM Mount 1

65-05241

Console ExtensionCable

45-05900: 5’ / 1.5m45-05901: 10’ / 3.0m45-05902: 20’ / 6.0m45-05903: 40’ / 12.0m

Battery Adapter 3

401-0016

BIM Harness 3

45-10159

Boom InterfaceModule (BIM) 2

78-05091

EndTerminator Male 2

45-05856TFMI Harness 2

45-10148

Tip Flow MonitorInterface 2

78-05101

Extension CableSensor 3

45-05857: 3’ / 0.9m45-05858: 6’ / 1.8m45-05859: 12’ / 3.7m45-05864: 35’ / 10.6m

Tip SensorInterface78-05104

Dual Tip SensorInterface78-05105

Nozzle Flowmeter57-00122

StartTerminator Female 2

45-05855

For Applicators and Planters with Single Boom Section

1 These items part of Kit 90-028712 These items part of Kit 90-028521, 2, & 3 These items part of Kit 90-02860

SENTRY 6140 TIP FLOW MONITOR

1 These items part of Kit 90-028712 These items part of Kit 90-028521, 2, & 3 These items part of Kit 90-02889