select the indoor unit to be installed in each room....
TRANSCRIPT
99
SERIES
SELECTIONChoose from five types of indoor units and twelve outdoor units that can run up to six indoor units each. Create the system that best matches room shapes and number of rooms.
MULTISPLIT
SELECT INDOOR UNITSSelect the indoor unit to be installed in each room.
Wall-mounted Floor-standing Cassette Ceiling-suspended
Ceiling-concealed
SELECT OUTDOOR UNITSSelect the best outdoor unit based on the number of indoor units and overall system capacity required.
2-port up to 2 indoor units 3-port up to 3 indoor units 4-port up to 4 indoor units
5-port up to 5 indoor units 6-port up to 6 indoor units 4-port up to 4 indoor units
CHECK SYSTEM COMPATIBILITYPossible combinations depends on the outdoor unit chosen. Please check the following points.
Refer to the “Indoor Unit Compatibility Table” to check if the indoor units selected can be used with the outdoor unit selected. (Indoor units not listed in the table cannot be used.)
Refer to the “Combination Table” to check if the capacity combination of the indoor unit selected is connectable. (Combinations not listed cannot be connected.)
Check Indoor Unit CapacityCombination
If the desired combination cannot be found, please change either the indoor or outdoor unit to match one of the combinations shown in the tables.
Check Indoor Units
MXZ-2D33VAMXZ-2D42VA2MXZ-2D53VA(H)2
MXZ-5E102VA MXZ-6D122VA
MXZ-3E54VAMXZ-3E68VA
MXZ-4E72VA MXZ-4E83VA
STEP 1
STEP 2
STEP 3
MXZ-4E83VAHZ
2-port up to 2 indoor units
MXZ-2E53VAHZ
MSZ-FH
MSZ-LN (25•35)
MSZ-EF MSZ-GF
MSZ-SF (25-50)MFZ-KJ
SLZ-KF
PLA
MLZ-KA
PCA
SEZ-KD
PEAD
HYPER HEATING*
*Refer to page105 and page 113 for detailed information.
MSZ-SF (15 •20)
100
SERIES
SELECTIONChoose from five types of indoor units and twelve outdoor units that can run up to six indoor units each. Create the system that best matches room shapes and number of rooms.
MULTISPLIT
SELECT INDOOR UNITSSelect the indoor unit to be installed in each room.
Wall-mounted Floor-standing Cassette Ceiling-suspended
Ceiling-concealed
SELECT OUTDOOR UNITSSelect the best outdoor unit based on the number of indoor units and overall system capacity required.
2-port up to 2 indoor units 3-port up to 3 indoor units 4-port up to 4 indoor units
5-port up to 5 indoor units 6-port up to 6 indoor units 4-port up to 4 indoor units
CHECK SYSTEM COMPATIBILITYPossible combinations depends on the outdoor unit chosen. Please check the following points.
Refer to the “Indoor Unit Compatibility Table” to check if the indoor units selected can be used with the outdoor unit selected. (Indoor units not listed in the table cannot be used.)
Refer to the “Combination Table” to check if the capacity combination of the indoor unit selected is connectable. (Combinations not listed cannot be connected.)
Check Indoor Unit CapacityCombination
If the desired combination cannot be found, please change either the indoor or outdoor unit to match one of the combinations shown in the tables.
Check Indoor Units
MXZ-2D33VAMXZ-2D42VA2MXZ-2D53VA(H)2
MXZ-5E102VA MXZ-6D122VA
MXZ-3E54VAMXZ-3E68VA
MXZ-4E72VA MXZ-4E83VA
STEP 1
STEP 2
STEP 3
MXZ-4E83VAHZ
2-port up to 2 indoor units
MXZ-2E53VAHZ
MSZ-FH
MSZ-LN (25•35)
MSZ-EF MSZ-GF
MSZ-SF (25-50)MFZ-KJ
SLZ-KF
PLA
MLZ-KA
PCA
SEZ-KD
PEAD
HYPER HEATING*
*Refer to page105 and page 113 for detailed information.
MSZ-SF (15 •20)
101
MXZ SERIESAdvancements in the MXZ Series include efficiency and flexibility in system expansion capabilities. The best solution when requiring multi-system air conditioning needs.
OutdoorUnit
EXAMPLE SYSTEM
Handle Up to 6 Rooms with a Single Outdoor Unit
Wiring/Piping Correction Function* (3E54/3E68/4E72/4E83/5E102/6D122)
Support Functions
The MXZ Series offers a nine-system line-up to choose from, ranging between 3.3 and 12.2kW. All of them are compatible with specific M, S and P series indoor units. A single outdoor unit can handle a wide range of building layouts.
2-port 3-port 4-port 4-port 5-port 6-port
MXZ-2D33VAMXZ-2D42VA2MXZ-2D53VA(H)2
MXZ-4E83VAMXZ-5E102VA
MXZ-3E54VAMXZ-3E68VAMXZ-4E72VA
MXZ-6D122VA
MXZ-6D122VA system
Simply press a single button to confirm if wiring and piping are prop-erly connected. Wiring errors are corrected automatically when dis-covered. This eliminates the need to confirm complicated wiring connections when expanding the system. (For details, refer to the outdoor unit installation manual.)* Function cannot be used when the outdoor temperature is below 0°C.
The correction process requires 10–20 minutes to complete and must be conducted with the unit set to the “Cooling” mode.
Ampere Limit Adjustment*(4E83/5E102/6D122)
Dipswitch settings can be used to adjust the maximum electrical current for operation. This function is highly recommended for man-aging energy costs. (For details, refer to the outdoor unit installation manual.)* Maximum capacity is lowered with the use of this function.
Operation Lock
To accommodate specific use applications, cooling or heating opera-tion can be specified when setting the control board of the outdoor unit. A convenient option when a system needs to be configured for exclusive cooling or heating service. (For details, refer to the outdoor unit installation manual.)
Wiringconfirmation
is timeconsuming.
The outdoor unit matches
pipes and wiring.
MXZ-6D122VA
2D-4E83
Up to 2 Indoor Units
Cooling
Heating(Average Season)
Max. Operating Current (Indoor+Outdoor)
Outdoor Unit
Ext. Piping
Guaranteed Operating Range [Outdoor]
SourceOutdoor (V/Phase/Hz)Capacity
Input (Indoor+Outdoor)Design LoadAnnual Electricity Consumption*2
SEER*4
Capacity
Input (Indoor+Outdoor)Design LoadDeclaredCapacity
Back Up Heating CapacityAnnual Electricity Consumption*2
SCOP*4
DimensionsWeightAir Volume
Sound Level (SPL)
Sound Level (PWL)Breaker SizeDiameter
Total Piping Length (max)Each Indoor Unit Piping Length (max)
Rated
Min - Max
Rated
Energy Efficiency Class*4
Rated
Min - Max
Rated
at reference design temperature
at bivalent temperature
at operation limit temperature
Energy Efficiency Class*4
H × W × D 550 - 800 (+69) - 285 (+59.5) 710 - 840 (+30) - 330 (+66) 796 - 950 - 330
Cooling
Heating
Cooling
Cooling
Heating
Liquid
Cooling
Heating
kW
kW
kW
kW
kWh/a
kW
kW
kW
kW
kW
kW
kW
kW
kWh/a
A
mm
kg
m3/min
m3/min
dB(A)
dB(A)
dB(A)
A
mm
Gas mm
m
m
Max. Height m
Chargeless Length moCoC
R410A*1
Outdoor power supply
230 / Single / 50
Please refer to (*4)N: MXZ-2D33VA N: MXZ-2D42VA2 N: MXZ-2D53VA2 N: MXZ-2D53VAH2 N: MXZ-3E54VA N: MXZ-3E68VA N: MXZ-4E72VA MXZ-4E83VA MXZ-5E102VA
Type (Inverter Multi - Split Heat Pump)Indoor Unit
Outdoor Unit
Refrigerant
Power Supply
3.3
1.1 - 3.8
0.90
3.3
211
5.5
A
4.0
1.0 - 4.1
0.96
2.7
2.1
2.4
1.7
0.6
926
4.1
A+
10.0
32
32.9
33.7
49
50
63
10
6.35 × 2
9.52 × 2
20
15
10
20
–10 ~ +46
–15 ~ +24
4.2
1.1 - 4.4
1.00
4.2
216
6.8
A++
4.5
1.0 - 4.8
0.93
3.2
2.7
3.0
2.3
0.5
1065
4.2
A+
12.2
37
27.7
33.3
46
51
60
15
6.35 × 2
9.52 × 2
30
20
15 (10)*3
20
–10 ~ +46
–15 ~ +24
5.3
1.1 - 5.6
1.54
5.3
262
7.1
A++
6.4
1.0 - 7.0
1.70
4.5
3.7
4.0
3.3
0.8
1507
4.2
A+
12.2
37
32.9
33.3
50
53
64
15
6.35 × 2
9.52 × 2
30
20
15 (10)*3
20
–10 ~ +46
–15 ~ +24
5.3
1.1 - 5.6
1.54
5.3
262
7.1
A++
6.4
1.0 - 7.0
1.70
4.5
3.6
4.0
3.0
0.9
1546
4.1
A+
12.2
38
32.9
33.3
50
53
64
15
6.35 × 2
9.52 × 2
30
20
15 (10)*3
20
–10 ~ +46
–20 ~ +24
5.4
2.9 - 6.8
1.35
5.4
295
6.4
A++
7.0
2.6 - 9.0
1.59
5.0
4.0
4.49
3.17
1.0
1751
4.0
A+
18.0
58
42.1
43.0
50
53
64
25
6.35 x 3
9.52 x 3
50
25
15 (10)*3
40
–10 ~ +46
–15 ~ +24
6.8
2.9 - 8.4
2.19
6.8
425
5.6
A+
8.6
2.6 - 10.6
2.38
6.8
5.4
6.0
4.4
1.4
2466
3.9
A
18.0
58
42.1
43.0
50
53
64
25
6.35 x 3
9.52 x 3
60
25
15 (10)*3
40
–10 ~ +46
–15 ~ +24
7.2
3.7 - 8.8
2.25
7.2
443
5.7
A+
8.6
3.4 - 10.7
2.28
7.0
5.6
6.2
4.7
1.4
2516
3.9
A
18.0
59
42.1
43.0
50
53
64
25
6.35 x 4
12.7×1+9.52×3
60
25
15 (10)*3
40
–10 ~ +46
–15 ~ +24
8.3
3.7 - 9.2
2.44
8.3
460
6.3
A++
9.3
3.4 - 11.6
2.00
8.7
7.1
7.8
6.0
1.6
2889
4.2
A+
21.4
63
55.6
55.6
49
51
61
25
6.35 × 4
12.7×1+9.52×3
70
25
15 (10)*3
25
–10 ~ +46
–15 ~ +24
10.2
3.9 - 11.0
3.15
10.2
537
6.6
A++
10.5
4.1 - 14.0
2.34
8.9
7.3
7.9
6.3
1.6
2958
4.2
A+
21.4
64
65.1
68.0
52
56
65
25
6.35 × 5
12.7×1+9.52×4
80
25
15 (10)*3
0
–10 ~ +46
–15 ~ +24
Up to 3 Indoor Units Up to 4 Indoor Units Up to 5 Indoor Units
Up to 6 Indoor Units
Cooling
Heating
Operating Current (max)*5
Outdoor Unit
Ext. Piping
Guaranteed Operating Range [Outdoor]
SourceOutdoor (V/Phase/Hz)Capacity
Input*5
EER*6
Capacity
Input*5
COP*6
DimensionsWeightAir Volume
Sound Level (SPL)
Sound Level (PWL)Breaker SizeDiameter
Total Piping Length (max)Each Indoor Unit Piping Length (max)
Rated
Rated
EEL RankRated
Rated
EEL Rank
H × W × D
Cooling
Heating
Cooling
Cooling
Heating
Liquid
Cooling
Heating
kW
kW
Min - Max kW
kW
Min - Max kW
kW
A
mm
kg
m3/min
m3/min
dB(A)
dB(A)
dB(A)
A
mm
Gas mm
m
m
Max. Height m
Chargeless Length moCoC
R410A*1
Outdoor power supply
230 / Single / 50
Please refer to (*5)
MXZ-6D122VA
Type (Inverter Multi - Split Heat Pump)Indoor Unit
Outdoor Unit
Refrigerant
Power Supply
12.2
3.5 - 13.5
3.66
3.33
A
14.0
3.5 - 16.5
3.31
4.23
A
26.8
1048 -950 -330
88
63.0
77.0
55
57
69
32
6.35×6
12.7×1+9.52×5
80
25
15 (10)*3
30
–10 ~ +46
–15 ~ +24
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.*3 If the outdoor unit is installed higher than the indoor unit, max. height is reduced to 10m.*4 EER/COP, EEL rank, SEER/SCOP values and energy efficiency class are measured
when connected to the indoor units listed below.MXZ-2D33VA MSZ-SF15VA + MSZ-EF18VEMXZ-2D42VA2 MSZ-EF18VE + MSZ-EF25VEMXZ-2D53VA(H)2 MSZ-EF18VE + MSZ-EF35VEMXZ-3E54VA MSZ-EF18VE + MSZ-EF18VE + MSZ-EF18VEMXZ-3E68VA MSZ-EF18VE + MSZ-EF25VE + MSZ-EF25VEMXZ-4E72VA MSZ-EF18VE + MSZ-EF18VE + MSZ-EF18VE + MSZ-EF18VEMXZ-4E83VA MSZ-EF18VE + MSZ-EF18VE + MSZ-EF22VE + MSZ-EF25VEMXZ-5E102VA MSZ-EF18VE + MSZ-EF18VE + MSZ-EF22VE + MSZ-EF22VE + MSZ-EF22VE
*5 Power input and operating current (max) figures are for outdoor unit only*6 EER/COP, EEL rank, values and energy efficiency class are measured
when connected to the indoor units listed below.MXZ-6D122VA MSZ-EF22VE × 6
N: Please refer to the NOTE below.
INVERTER MULTIMXZ SERIES
Please fill out the requested informationPlease fill out the requested information
NOTEWhen connecting the MFZ-KJ series indoor unit(s) to this outdoor unit, charge additional refrigerant according to the instructions in the diagram below.
MXZ-2D33VA
No. ofMFZ-KJ indoor units
Maximum amountof refrigerant
Pipe length (L)
~20m
100g additional (Total 1250g)1 unit
2 units
1250g
MXZ-2D42VA2 MXZ-2D53VA2 MXZ-2D53VAH2
No. ofMFZ-KJ indoor units
Maximum amountof refrigerant
Pipe length (L)
~20m
100g additional (Total 1400g)
200g additional (Total 1500g)
~30m
100g+{(L-20)m×20g/m)}
200g+{(L-20)m×20g/m)}
1 unit
2 units
1600g
1700g
MXZ-3E54VA
No. ofMFZ-KJ indoor units
Maximum amountof refrigerant
Pipe length (L)
~40m
100g additional (Total 2800g)
200g additional (Total 2900g)
300g additional (Total 3000g)
~50m
100g+{(L-40)m×20g/m)}
200g+{(L-40)m×20g/m)}
300g+{(L-40)m×20g/m)}
1 unit
2 units
3 units
3000g
3100g
3200g
MXZ-3E68VA MXZ-4E72VA
No. ofMFZ-KJ indoor units
Maximum amountof refrigerant
Pipe length (L)
~40m
100g additional (Total 2800g)
200g additional (Total 2900g)
300g additional (Total 3000g)
~60m
100g+{(L-40)m×20g/m)}
200g+{(L-40)m×20g/m)}
300g+{(L-40)m×20g/m)}
1 unit
2 units
3 units
3200g
3300g
3400g
Not available (Only one MFZ-KJ series indoor unit can be connected.)
MSZ-FH
MLZ-KA
MSZ-SF
MSZ-EF
SLZ-KF
MFZ-KJ
4E83-6D 3D-4D72
102
MXZ SERIESAdvancements in the MXZ Series include efficiency and flexibility in system expansion capabilities. The best solution when requiring multi-system air conditioning needs.
OutdoorUnit
EXAMPLE SYSTEM
Handle Up to 6 Rooms with a Single Outdoor Unit
Wiring/Piping Correction Function* (3E54/3E68/4E72/4E83/5E102/6D122)
Support Functions
The MXZ Series offers a nine-system line-up to choose from, ranging between 3.3 and 12.2kW. All of them are compatible with specific M, S and P series indoor units. A single outdoor unit can handle a wide range of building layouts.
2-port 3-port 4-port 4-port 5-port 6-port
MXZ-2D33VAMXZ-2D42VA2MXZ-2D53VA(H)2
MXZ-4E83VAMXZ-5E102VA
MXZ-3E54VAMXZ-3E68VAMXZ-4E72VA
MXZ-6D122VA
MXZ-6D122VA system
Simply press a single button to confirm if wiring and piping are prop-erly connected. Wiring errors are corrected automatically when dis-covered. This eliminates the need to confirm complicated wiring connections when expanding the system. (For details, refer to the outdoor unit installation manual.)* Function cannot be used when the outdoor temperature is below 0°C.
The correction process requires 10–20 minutes to complete and must be conducted with the unit set to the “Cooling” mode.
Ampere Limit Adjustment*(4E83/5E102/6D122)
Dipswitch settings can be used to adjust the maximum electrical current for operation. This function is highly recommended for man-aging energy costs. (For details, refer to the outdoor unit installation manual.)* Maximum capacity is lowered with the use of this function.
Operation Lock
To accommodate specific use applications, cooling or heating opera-tion can be specified when setting the control board of the outdoor unit. A convenient option when a system needs to be configured for exclusive cooling or heating service. (For details, refer to the outdoor unit installation manual.)
Wiringconfirmation
is timeconsuming.
The outdoor unit matches
pipes and wiring.
MXZ-6D122VA
2D-4E83
Up to 2 Indoor Units
Cooling
Heating(Average Season)
Max. Operating Current (Indoor+Outdoor)
Outdoor Unit
Ext. Piping
Guaranteed Operating Range [Outdoor]
SourceOutdoor (V/Phase/Hz)Capacity
Input (Indoor+Outdoor)Design LoadAnnual Electricity Consumption*2
SEER*4
Capacity
Input (Indoor+Outdoor)Design LoadDeclaredCapacity
Back Up Heating CapacityAnnual Electricity Consumption*2
SCOP*4
DimensionsWeightAir Volume
Sound Level (SPL)
Sound Level (PWL)Breaker SizeDiameter
Total Piping Length (max)Each Indoor Unit Piping Length (max)
Rated
Min - Max
Rated
Energy Efficiency Class*4
Rated
Min - Max
Rated
at reference design temperature
at bivalent temperature
at operation limit temperature
Energy Efficiency Class*4
H × W × D 550 - 800 (+69) - 285 (+59.5) 710 - 840 (+30) - 330 (+66) 796 - 950 - 330
Cooling
Heating
Cooling
Cooling
Heating
Liquid
Cooling
Heating
kW
kW
kW
kW
kWh/a
kW
kW
kW
kW
kW
kW
kW
kW
kWh/a
A
mm
kg
m3/min
m3/min
dB(A)
dB(A)
dB(A)
A
mm
Gas mm
m
m
Max. Height m
Chargeless Length moCoC
R410A*1
Outdoor power supply
230 / Single / 50
Please refer to (*4)N: MXZ-2D33VA N: MXZ-2D42VA2 N: MXZ-2D53VA2 N: MXZ-2D53VAH2 N: MXZ-3E54VA N: MXZ-3E68VA N: MXZ-4E72VA MXZ-4E83VA MXZ-5E102VA
Type (Inverter Multi - Split Heat Pump)Indoor Unit
Outdoor Unit
Refrigerant
Power Supply
3.3
1.1 - 3.8
0.90
3.3
211
5.5
A
4.0
1.0 - 4.1
0.96
2.7
2.1
2.4
1.7
0.6
926
4.1
A+
10.0
32
32.9
33.7
49
50
63
10
6.35 × 2
9.52 × 2
20
15
10
20
–10 ~ +46
–15 ~ +24
4.2
1.1 - 4.4
1.00
4.2
216
6.8
A++
4.5
1.0 - 4.8
0.93
3.2
2.7
3.0
2.3
0.5
1065
4.2
A+
12.2
37
27.7
33.3
46
51
60
15
6.35 × 2
9.52 × 2
30
20
15 (10)*3
20
–10 ~ +46
–15 ~ +24
5.3
1.1 - 5.6
1.54
5.3
262
7.1
A++
6.4
1.0 - 7.0
1.70
4.5
3.7
4.0
3.3
0.8
1507
4.2
A+
12.2
37
32.9
33.3
50
53
64
15
6.35 × 2
9.52 × 2
30
20
15 (10)*3
20
–10 ~ +46
–15 ~ +24
5.3
1.1 - 5.6
1.54
5.3
262
7.1
A++
6.4
1.0 - 7.0
1.70
4.5
3.6
4.0
3.0
0.9
1546
4.1
A+
12.2
38
32.9
33.3
50
53
64
15
6.35 × 2
9.52 × 2
30
20
15 (10)*3
20
–10 ~ +46
–20 ~ +24
5.4
2.9 - 6.8
1.35
5.4
295
6.4
A++
7.0
2.6 - 9.0
1.59
5.0
4.0
4.49
3.17
1.0
1751
4.0
A+
18.0
58
42.1
43.0
50
53
64
25
6.35 x 3
9.52 x 3
50
25
15 (10)*3
40
–10 ~ +46
–15 ~ +24
6.8
2.9 - 8.4
2.19
6.8
425
5.6
A+
8.6
2.6 - 10.6
2.38
6.8
5.4
6.0
4.4
1.4
2466
3.9
A
18.0
58
42.1
43.0
50
53
64
25
6.35 x 3
9.52 x 3
60
25
15 (10)*3
40
–10 ~ +46
–15 ~ +24
7.2
3.7 - 8.8
2.25
7.2
443
5.7
A+
8.6
3.4 - 10.7
2.28
7.0
5.6
6.2
4.7
1.4
2516
3.9
A
18.0
59
42.1
43.0
50
53
64
25
6.35 x 4
12.7×1+9.52×3
60
25
15 (10)*3
40
–10 ~ +46
–15 ~ +24
8.3
3.7 - 9.2
2.44
8.3
460
6.3
A++
9.3
3.4 - 11.6
2.00
8.7
7.1
7.8
6.0
1.6
2889
4.2
A+
21.4
63
55.6
55.6
49
51
61
25
6.35 × 4
12.7×1+9.52×3
70
25
15 (10)*3
25
–10 ~ +46
–15 ~ +24
10.2
3.9 - 11.0
3.15
10.2
537
6.6
A++
10.5
4.1 - 14.0
2.34
8.9
7.3
7.9
6.3
1.6
2958
4.2
A+
21.4
64
65.1
68.0
52
56
65
25
6.35 × 5
12.7×1+9.52×4
80
25
15 (10)*3
0
–10 ~ +46
–15 ~ +24
Up to 3 Indoor Units Up to 4 Indoor Units Up to 5 Indoor Units
Up to 6 Indoor Units
Cooling
Heating
Operating Current (max)*5
Outdoor Unit
Ext. Piping
Guaranteed Operating Range [Outdoor]
SourceOutdoor (V/Phase/Hz)Capacity
Input*5
EER*6
Capacity
Input*5
COP*6
DimensionsWeightAir Volume
Sound Level (SPL)
Sound Level (PWL)Breaker SizeDiameter
Total Piping Length (max)Each Indoor Unit Piping Length (max)
Rated
Rated
EEL RankRated
Rated
EEL Rank
H × W × D
Cooling
Heating
Cooling
Cooling
Heating
Liquid
Cooling
Heating
kW
kW
Min - Max kW
kW
Min - Max kW
kW
A
mm
kg
m3/min
m3/min
dB(A)
dB(A)
dB(A)
A
mm
Gas mm
m
m
Max. Height m
Chargeless Length moCoC
R410A*1
Outdoor power supply
230 / Single / 50
Please refer to (*5)
MXZ-6D122VA
Type (Inverter Multi - Split Heat Pump)Indoor Unit
Outdoor Unit
Refrigerant
Power Supply
12.2
3.5 - 13.5
3.66
3.33
A
14.0
3.5 - 16.5
3.31
4.23
A
26.8
1048 -950 -330
88
63.0
77.0
55
57
69
32
6.35×6
12.7×1+9.52×5
80
25
15 (10)*3
30
–10 ~ +46
–15 ~ +24
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.*3 If the outdoor unit is installed higher than the indoor unit, max. height is reduced to 10m.*4 EER/COP, EEL rank, SEER/SCOP values and energy efficiency class are measured
when connected to the indoor units listed below.MXZ-2D33VA MSZ-SF15VA + MSZ-EF18VEMXZ-2D42VA2 MSZ-EF18VE + MSZ-EF25VEMXZ-2D53VA(H)2 MSZ-EF18VE + MSZ-EF35VEMXZ-3E54VA MSZ-EF18VE + MSZ-EF18VE + MSZ-EF18VEMXZ-3E68VA MSZ-EF18VE + MSZ-EF25VE + MSZ-EF25VEMXZ-4E72VA MSZ-EF18VE + MSZ-EF18VE + MSZ-EF18VE + MSZ-EF18VEMXZ-4E83VA MSZ-EF18VE + MSZ-EF18VE + MSZ-EF22VE + MSZ-EF25VEMXZ-5E102VA MSZ-EF18VE + MSZ-EF18VE + MSZ-EF22VE + MSZ-EF22VE + MSZ-EF22VE
*5 Power input and operating current (max) figures are for outdoor unit only*6 EER/COP, EEL rank, values and energy efficiency class are measured
when connected to the indoor units listed below.MXZ-6D122VA MSZ-EF22VE × 6
N: Please refer to the NOTE below.
INVERTER MULTIMXZ SERIES
Please fill out the requested informationPlease fill out the requested information
NOTEWhen connecting the MFZ-KJ series indoor unit(s) to this outdoor unit, charge additional refrigerant according to the instructions in the diagram below.
MXZ-2D33VA
No. ofMFZ-KJ indoor units
Maximum amountof refrigerant
Pipe length (L)
~20m
100g additional (Total 1250g)1 unit
2 units
1250g
MXZ-2D42VA2 MXZ-2D53VA2 MXZ-2D53VAH2
No. ofMFZ-KJ indoor units
Maximum amountof refrigerant
Pipe length (L)
~20m
100g additional (Total 1400g)
200g additional (Total 1500g)
~30m
100g+{(L-20)m×20g/m)}
200g+{(L-20)m×20g/m)}
1 unit
2 units
1600g
1700g
MXZ-3E54VA
No. ofMFZ-KJ indoor units
Maximum amountof refrigerant
Pipe length (L)
~40m
100g additional (Total 2800g)
200g additional (Total 2900g)
300g additional (Total 3000g)
~50m
100g+{(L-40)m×20g/m)}
200g+{(L-40)m×20g/m)}
300g+{(L-40)m×20g/m)}
1 unit
2 units
3 units
3000g
3100g
3200g
MXZ-3E68VA MXZ-4E72VA
No. ofMFZ-KJ indoor units
Maximum amountof refrigerant
Pipe length (L)
~40m
100g additional (Total 2800g)
200g additional (Total 2900g)
300g additional (Total 3000g)
~60m
100g+{(L-40)m×20g/m)}
200g+{(L-40)m×20g/m)}
300g+{(L-40)m×20g/m)}
1 unit
2 units
3 units
3200g
3300g
3400g
Not available (Only one MFZ-KJ series indoor unit can be connected.)
MSZ-FH
MLZ-KA
MSZ-SF
MSZ-EF
SLZ-KF
MFZ-KJ
4E83-6D 3D-4D72
103
MXZ-DM SERIESMulti-port outdoor units exclusively for MSZ-HJ and DM indoor units.
2-port 3-port
MXZ-2DM40VA MXZ-3DM50VA
Up to 2 Indoor Units
Cooling
Heating(Average Season)
Operating Current (max)
Outdoor Unit
Ext. Piping
Guaranteed Operating Range [Outdoor]
SourceOutdoor (V/Phase/Hz)
CapacityInput*4
EER*4
SEER*4
Design LoadAnnual Electricity Consumption*2
CapacityInputCOP*4
DeclaredCapacity
Design Load
Back Up Heating CapacityAnnual Electricity Consumption*2
SCOP*4
DimensionsWeightAir Volume
Sound Level (SPL)
Sound Level (PWL)
Breaker SizePort DiameterTotal Piping Length (max)Each Indoor Unit Piping Length (max)
Rated
Rated
EEL Rank*4
Energy Efficiency Class*4
Rated
Rated
EEL Rank*4
at reference design temperature
at bivalent temperature
at operation limit temperature
Energy Efficiency Class*4
H × W × D
Cooling
Heating
Cooling
Cooling
Heating
Liquid / Gas
Cooling
Heating
kW
kW
kW
kWh/a
kW
kW
kW
kW
kW
kW
kW
kWh/a
A
mm
kg
m3/min
m3/min
dB(A)
dB(A)
dB(A)
Operating Current Cooling A
Heating A
A
mm
m
m
Max. Height m
Chargeless Length moCoC
R410A*1
Outdoor power supply
230 / Single / 50
Please refer to (*4)
MXZ-2DM40VA MXZ-3DM50VA
Type (Inverter Multi - Split Heat Pump)Indoor Unit
Outdoor Unit
Refrigerant
Power Supply
4.0
1.05
3.81
A
4.0
226
6.1
A++
4.3
1.16
3.71
A
3.2
2.73
3.01
2.27
0.47
1105
4.0
A+
12.2
550 - 800 (+69) - 285 (+59.5)
32
29.2
31.9
48
52
63
5.1
5.6
15
6.35 × 2 / 9.52 × 2
30
20
15 (10)*3
20
5.0
1.13
4.42
A
5.0
283
6.1
A++
6.0
1.31
4.58
A
4.0
3.34
3.73
2.70
0.66
1455
3.8
A
18.0
710 - 840 (+30) - 330 (+66)
57
37.5
39.6
50
53
64
5.0
5.8
25
6.35 × 3 / 9.52 × 3
50
25
15 (10)*3
40
Up to 3 Indoor Units
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.*3 If the outdoor unit is installed higher than the indoor unit, max hight is reduced to 10m.*4 EER/COP, EEL rank, SEER/SCOP values and energy efficiency class are measured when connected to the indoor units listed below.
MXZ-2DM40VA MSZ-DM25VA + MSZ-DM25VA MXZ-3DM50VA MSZ-DM25VA + MSZ-DM25VA + MSZ-DM25VA
INVERTER MULTIMXZ-DM SERIES
Please fill out the requested informationPlease fill out the requested information
Stylish Design with Flat Panel Front
Easy to create various combinations
A stylish flat panel design is employed for the front of the indoor unit. The simple look matches room aesthetics.
Wide range of simple combinations only possible using multi-port outdoor units.
MXZ-DM is exclusively for connection to MSZ-HJ and DM.Please check to make sure that wiring is done correctly.
For MXZ-DMFor MSZ-HJ/DM / MUZ-HJ/DM
S1
MSZ-HJ/DMMXZ-2DMMXZ-3DM
S2 S3 N L
S3 N N~L~L
S1 S2 S3 N L
S1 S2 S3
MSZ-HJ/DMMUZ-HJ/DM
Attention
Two bedrooms Three bedrooms
Living room and one bedroom Wide living room
3HJ
–10 ~ +46
–15 ~ +24
104
MXZ-DM SERIESMulti-port outdoor units exclusively for MSZ-HJ and DM indoor units.
2-port 3-port
MXZ-2DM40VA MXZ-3DM50VA
Up to 2 Indoor Units
Cooling
Heating(Average Season)
Operating Current (max)
Outdoor Unit
Ext. Piping
Guaranteed Operating Range [Outdoor]
SourceOutdoor (V/Phase/Hz)
CapacityInput*4
EER*4
SEER*4
Design LoadAnnual Electricity Consumption*2
CapacityInputCOP*4
DeclaredCapacity
Design Load
Back Up Heating CapacityAnnual Electricity Consumption*2
SCOP*4
DimensionsWeightAir Volume
Sound Level (SPL)
Sound Level (PWL)
Breaker SizePort DiameterTotal Piping Length (max)Each Indoor Unit Piping Length (max)
Rated
Rated
EEL Rank*4
Energy Efficiency Class*4
Rated
Rated
EEL Rank*4
at reference design temperature
at bivalent temperature
at operation limit temperature
Energy Efficiency Class*4
H × W × D
Cooling
Heating
Cooling
Cooling
Heating
Liquid / Gas
Cooling
Heating
kW
kW
kW
kWh/a
kW
kW
kW
kW
kW
kW
kW
kWh/a
A
mm
kg
m3/min
m3/min
dB(A)
dB(A)
dB(A)
Operating Current Cooling A
Heating A
A
mm
m
m
Max. Height m
Chargeless Length moCoC
R410A*1
Outdoor power supply
230 / Single / 50
Please refer to (*4)
MXZ-2DM40VA MXZ-3DM50VA
Type (Inverter Multi - Split Heat Pump)Indoor Unit
Outdoor Unit
Refrigerant
Power Supply
4.0
1.05
3.81
A
4.0
226
6.1
A++
4.3
1.16
3.71
A
3.2
2.73
3.01
2.27
0.47
1105
4.0
A+
12.2
550 - 800 (+69) - 285 (+59.5)
32
29.2
31.9
48
52
63
5.1
5.6
15
6.35 × 2 / 9.52 × 2
30
20
15 (10)*3
20
5.0
1.13
4.42
A
5.0
283
6.1
A++
6.0
1.31
4.58
A
4.0
3.34
3.73
2.70
0.66
1455
3.8
A
18.0
710 - 840 (+30) - 330 (+66)
57
37.5
39.6
50
53
64
5.0
5.8
25
6.35 × 3 / 9.52 × 3
50
25
15 (10)*3
40
Up to 3 Indoor Units
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.*3 If the outdoor unit is installed higher than the indoor unit, max hight is reduced to 10m.*4 EER/COP, EEL rank, SEER/SCOP values and energy efficiency class are measured when connected to the indoor units listed below.
MXZ-2DM40VA MSZ-DM25VA + MSZ-DM25VA MXZ-3DM50VA MSZ-DM25VA + MSZ-DM25VA + MSZ-DM25VA
INVERTER MULTIMXZ-DM SERIES
Please fill out the requested informationPlease fill out the requested information
Stylish Design with Flat Panel Front
Easy to create various combinations
A stylish flat panel design is employed for the front of the indoor unit. The simple look matches room aesthetics.
Wide range of simple combinations only possible using multi-port outdoor units.
MXZ-DM is exclusively for connection to MSZ-HJ and DM.Please check to make sure that wiring is done correctly.
For MXZ-DMFor MSZ-HJ/DM / MUZ-HJ/DM
S1
MSZ-HJ/DMMXZ-2DMMXZ-3DM
S2 S3 N L
S3 N N~L~L
S1 S2 S3 N L
S1 S2 S3
MSZ-HJ/DMMUZ-HJ/DM
Attention
Two bedrooms Three bedrooms
Living room and one bedroom Wide living room
3HJ
–10 ~ +46
–15 ~ +24
105
PUMYSERIESAir conditioning system supports replacement work by simplifying the installa-tion process. Ideal for supporting renewal needs at small offices and stores, home offices, etc.
EXAMPLE SYSTEM
The two-pipe zoned system designed for Heat Pump Operation
PUMY series make use of a two-pipe refrigerant system, which allows for system changeover from cooling to heating, ensuring that a constant indoor climate is maintained in all zones. The compact outdoor unit utilizes R410A refrigerant and an INVERTER-driven compressor to use energy effectively.With a wide range of indoor unit line-up in connection with a flexible piping system, PUMY series can be configured for all applications. Up to 12 indoor units can be connected with up to 130% connected capacity to maximize engineer's design options. This feature allows easy air condition-ing in each area with convenient individual controllers.
PUMY-P112/125/140VKM3(-BS)PUMY-P112/125/140YKM3(-BS)PUMY-P200YKM1(-BS)
2D-4D72
Cooling Capacity(nominal)
Temp. Range of Cooling*5
Temp. Range of Heating
Heating Capacity(nominal)
Sound Pressure Level(measured in anechoic room)
Indoor27°C DB / 19°C WB
20°C DB
CoolingHeating
Outdoor35°C
7°C DB / 6°C WB
Piping Length7.5m
7.5m
Level Difference0m
0m
Indoor Unit Connectable
Fan
Compressor
External Dimensions (H × W × D)Weight
Liquid PipeGas PipeType × QuantityAir Flow Rate
Motor OutputType × QuantityStarting MethodMotor Output
mm
mm
m3/min
L/s
cfm
kW
kW
mm
kg
*1
*2
50 to 130% of outdoor unit capacity
9.52 Flare
15.88 Flare
Propeller Fan × 2
110
1,883
3,884
0.074 + 0.074
Scroll hermetic compressor × 1
Inverter
1,338×1,050×330 (+25)
9.52*6 Flare
19.1 Flare
139
2,316
4,908
0.20 + 0.20
137
2.9 3.5
122
3.9 2.9 3.5
125
3.9
kW
kW
A
kW/kW
W.B.
D.B.
kW
kW
A
kW/kW
D.B.
W.B.
City Multi
Branch Box
Mixed System
dB <A>
1-phase 220 - 230 - 240V 50Hz 3-phase 380 - 400 - 415V 50HzModelPower Source
12.5
2.79
12.87 - 12.32 - 11.80
4.48
15.0 - 24.0°C
-5.0 - 52°C
14.0
3.04
14.03 - 13.42 - 12.86
4.61
15.0 - 27.0°C
-20.0 - 15.0°C
15 - 140 / 9
15 - 100 / 8
15 - 140*3/10
49 / 51
14.0
3.46
15.97 - 15.27 - 14.64
4.05
15.0 - 24.0°C
-5.0 - 52°C
16.0
3.74
17.26 - 16.51 - 15.82
4.28
15.0 - 27.0°C
-20.0 - 15.0°C
15 - 140 / 10
15 - 100 / 8
15 - 140*3/10*4
50 / 52
15.5
4.52
20.86 - 19.95 - 19.12
3.43
15.0 - 24.0°C
-5.0 - 52°C
18.0
4.47
20.63 - 19.73 - 18.91
4.03
15.0 - 27.0°C
-20.0 - 15.0°C
15 - 140 / 12
15 - 100 / 8
15 - 140*3/10*4
51 / 53
12.5
2.79
4.99 - 4.74 - 4.57
4.48
15.0 - 24.0°C
-5.0 - 52°C
14.0
3.04
5.43 - 5.16 - 4.98
4.61
15.0 - 27.0°C
-20.0 - 15.0°C
15 - 140 / 9
15 - 100 / 8
15 - 140*3/10
49 / 51
14.0
3.46
5.84 - 5.55 - 5.35
4.05
15.0 - 24.0°C
-5.0 - 52°C
16.0
3.74
6.31 - 6.00 - 5.78
4.28
15.0 - 27.0°C
-20.0 - 15.0°C
15 - 140 / 10
15 - 100 / 8
15 - 140*3/10*4
50 / 52
15.5
4.52
7.23 - 6.87 - 6.62
3.43
15.0 - 24.0°C
-5.0 - 52°C
18.0
4.47
7.15 - 6.79 - 6.55
4.03
15.0 - 27.0°C
-20.0 - 15.0°C
15 - 140 / 12
15 - 100 / 8
15 - 140*3/10*4
51 / 53
PUMY-P140VKM3(-BS) PUMY-P112YKM3(-BS) PUMY-P125YKM3(-BS) PUMY-P140YKM3(-BS)
5.3
22.4
6.05
9.88 - 9.39 - 9.05
3.70
15.0 - 24.0°C
-5.0 - 52°C
25.0
5.84
9.54 - 9.06 - 8.74
4.28
15.0 - 27.0°C
-20.0 - 15.0°C
15 - 200 / 12
15 - 100 / 8
15 - 200*3/10*4
56 / 61
PUMY-P200YKM1(-BS)PUMY-P125VKM3(-BS)PUMY-P112VKM3(-BS)
Branch Box
Total InputOperating CurrentDimensionsWeightPiping[diameter]
Branch[Indoor Side]
Main[Outdoor Side]
Connection Methodto Indoor Unitto Outdoor Unit
Wiring
SourceOutdoor (V/Phase/Hz)
Liquid
Gas
Liquid
Gas
kW
mm
kg
mm
mm
mm
mm
H × W × D
A
PAC-MK52BC
Max. 5Outdoor power supply, Branch Box / Outdoor separate power supply
1-phase, 220 - 230 - 240V, 50Hz
PAC-MK32BC
Max. 3
TypeModel Name
Connectable Number of Indoor Units
Power Supply
INVERTER MULTIPUMY SERIES
MSZ-FH
MFZ-KJ
CITY MULTIindoor unit
Branch Box
MSZ-EF
4D83-6C 3D-5D
Total lengthMaximum allowable lengthFarthest indoor from first branch
300150 (175 equivalent)
30
Outdoor unit
Indoor unitBetweenindoor units top-bottomdifferential15m*
*In case of branch box connection: 12m
Refrigerant Piping Lengths Maximum meters
[P112–140V/YKM3(-BS)]
Furthest piping length 175m (equivalent length) (actual length 150m)
Silent mode can reduce sound pressure level by 3dB(A)
Indoor/outdoor (outdoor higher)Indoor/outdoor (outdoor lower)Indoor/indoor
5040
15*
Vertical differentials between units Maximum meters
Total lengthMaximum allowable lengthFarthest indoor from first branch
1508030
Refrigerant Piping Lengths Maximum meters
[P200YKM1(-BS)]
Indoor/outdoor (outdoor higher)Indoor/outdoor (outdoor lower)Indoor/indoor
5040
15*
Vertical differentials between units Maximum meters
Top-bottom differential 50m
Outdoor unit
Outdoor unit
Branch Box
Small Offices Residence
Power InputCurrent InputEERIndoor Temp.Outdoor Temp.
Power InputCurrent InputCOPIndoor Temp.Outdoor Temp.Total CapacityModel / Quantity
*1,*2 Nominal conditions
*3 Up to P100 when connecting via branch box. *4 Up to 11 units when connecting via 2 branch boxes*5 10 to 52°C D.B.: When connecting PKFY-P15/20/25VBM, PFFY-P20/25/32VKM and PFFY-P20/25/32VLE(R)M, PEFY-P-VMA3, M, S and P series indoor unit.*6 Liquid pipe diameter: 12.7mm when piping length is more than 60m.
0.003
0.05
170 - 450 - 280
9.52
15.88
3-wire + Earth wire
3-wire + Earth wire
Flared Brazed
7.4
6.35 × 5
9.52 × 4, 12.7 × 1
6.7
6.35 × 3
9.52 × 3
PAC-MK52BCB
Max. 5
PAC-MK32BCB
Max. 3
7.0
6.35 × 5
9.52 × 4, 12.7 × 1
6.5
6.35 × 3
9.52 × 3
Branch Box
PUMY-P112/125/140V(Y)KM3(-BS)PUMY-P200YKM1(-BS)
Refrigerant Piping Diameter
106
PUMYSERIESAir conditioning system supports replacement work by simplifying the installa-tion process. Ideal for supporting renewal needs at small offices and stores, home offices, etc.
EXAMPLE SYSTEM
The two-pipe zoned system designed for Heat Pump Operation
PUMY series make use of a two-pipe refrigerant system, which allows for system changeover from cooling to heating, ensuring that a constant indoor climate is maintained in all zones. The compact outdoor unit utilizes R410A refrigerant and an INVERTER-driven compressor to use energy effectively.With a wide range of indoor unit line-up in connection with a flexible piping system, PUMY series can be configured for all applications. Up to 12 indoor units can be connected with up to 130% connected capacity to maximize engineer's design options. This feature allows easy air condition-ing in each area with convenient individual controllers.
PUMY-P112/125/140VKM3(-BS)PUMY-P112/125/140YKM3(-BS)PUMY-P200YKM1(-BS)
2D-4D72
Cooling Capacity(nominal)
Temp. Range of Cooling*5
Temp. Range of Heating
Heating Capacity(nominal)
Sound Pressure Level(measured in anechoic room)
Indoor27°C DB / 19°C WB
20°C DB
CoolingHeating
Outdoor35°C
7°C DB / 6°C WB
Piping Length7.5m
7.5m
Level Difference0m
0m
Indoor Unit Connectable
Fan
Compressor
External Dimensions (H × W × D)Weight
Liquid PipeGas PipeType × QuantityAir Flow Rate
Motor OutputType × QuantityStarting MethodMotor Output
mm
mm
m3/min
L/s
cfm
kW
kW
mm
kg
*1
*2
50 to 130% of outdoor unit capacity
9.52 Flare
15.88 Flare
Propeller Fan × 2
110
1,883
3,884
0.074 + 0.074
Scroll hermetic compressor × 1
Inverter
1,338×1,050×330 (+25)
9.52*6 Flare
19.1 Flare
139
2,316
4,908
0.20 + 0.20
137
2.9 3.5
122
3.9 2.9 3.5
125
3.9
kW
kW
A
kW/kW
W.B.
D.B.
kW
kW
A
kW/kW
D.B.
W.B.
City Multi
Branch Box
Mixed System
dB <A>
1-phase 220 - 230 - 240V 50Hz 3-phase 380 - 400 - 415V 50HzModelPower Source
12.5
2.79
12.87 - 12.32 - 11.80
4.48
15.0 - 24.0°C
-5.0 - 52°C
14.0
3.04
14.03 - 13.42 - 12.86
4.61
15.0 - 27.0°C
-20.0 - 15.0°C
15 - 140 / 9
15 - 100 / 8
15 - 140*3/10
49 / 51
14.0
3.46
15.97 - 15.27 - 14.64
4.05
15.0 - 24.0°C
-5.0 - 52°C
16.0
3.74
17.26 - 16.51 - 15.82
4.28
15.0 - 27.0°C
-20.0 - 15.0°C
15 - 140 / 10
15 - 100 / 8
15 - 140*3/10*4
50 / 52
15.5
4.52
20.86 - 19.95 - 19.12
3.43
15.0 - 24.0°C
-5.0 - 52°C
18.0
4.47
20.63 - 19.73 - 18.91
4.03
15.0 - 27.0°C
-20.0 - 15.0°C
15 - 140 / 12
15 - 100 / 8
15 - 140*3/10*4
51 / 53
12.5
2.79
4.99 - 4.74 - 4.57
4.48
15.0 - 24.0°C
-5.0 - 52°C
14.0
3.04
5.43 - 5.16 - 4.98
4.61
15.0 - 27.0°C
-20.0 - 15.0°C
15 - 140 / 9
15 - 100 / 8
15 - 140*3/10
49 / 51
14.0
3.46
5.84 - 5.55 - 5.35
4.05
15.0 - 24.0°C
-5.0 - 52°C
16.0
3.74
6.31 - 6.00 - 5.78
4.28
15.0 - 27.0°C
-20.0 - 15.0°C
15 - 140 / 10
15 - 100 / 8
15 - 140*3/10*4
50 / 52
15.5
4.52
7.23 - 6.87 - 6.62
3.43
15.0 - 24.0°C
-5.0 - 52°C
18.0
4.47
7.15 - 6.79 - 6.55
4.03
15.0 - 27.0°C
-20.0 - 15.0°C
15 - 140 / 12
15 - 100 / 8
15 - 140*3/10*4
51 / 53
PUMY-P140VKM3(-BS) PUMY-P112YKM3(-BS) PUMY-P125YKM3(-BS) PUMY-P140YKM3(-BS)
5.3
22.4
6.05
9.88 - 9.39 - 9.05
3.70
15.0 - 24.0°C
-5.0 - 52°C
25.0
5.84
9.54 - 9.06 - 8.74
4.28
15.0 - 27.0°C
-20.0 - 15.0°C
15 - 200 / 12
15 - 100 / 8
15 - 200*3/10*4
56 / 61
PUMY-P200YKM1(-BS)PUMY-P125VKM3(-BS)PUMY-P112VKM3(-BS)
Branch Box
Total InputOperating CurrentDimensionsWeightPiping[diameter]
Branch[Indoor Side]
Main[Outdoor Side]
Connection Methodto Indoor Unitto Outdoor Unit
Wiring
SourceOutdoor (V/Phase/Hz)
Liquid
Gas
Liquid
Gas
kW
mm
kg
mm
mm
mm
mm
H × W × D
A
PAC-MK52BC
Max. 5Outdoor power supply, Branch Box / Outdoor separate power supply
1-phase, 220 - 230 - 240V, 50Hz
PAC-MK32BC
Max. 3
TypeModel Name
Connectable Number of Indoor Units
Power Supply
INVERTER MULTIPUMY SERIES
MSZ-FH
MFZ-KJ
CITY MULTIindoor unit
Branch Box
MSZ-EF
4D83-6C 3D-5D
Total lengthMaximum allowable lengthFarthest indoor from first branch
300150 (175 equivalent)
30
Outdoor unit
Indoor unitBetweenindoor units top-bottomdifferential15m*
*In case of branch box connection: 12m
Refrigerant Piping Lengths Maximum meters
[P112–140V/YKM3(-BS)]
Furthest piping length 175m (equivalent length) (actual length 150m)
Silent mode can reduce sound pressure level by 3dB(A)
Indoor/outdoor (outdoor higher)Indoor/outdoor (outdoor lower)Indoor/indoor
5040
15*
Vertical differentials between units Maximum meters
Total lengthMaximum allowable lengthFarthest indoor from first branch
1508030
Refrigerant Piping Lengths Maximum meters
[P200YKM1(-BS)]
Indoor/outdoor (outdoor higher)Indoor/outdoor (outdoor lower)Indoor/indoor
5040
15*
Vertical differentials between units Maximum meters
Top-bottom differential 50m
Outdoor unit
Outdoor unit
Branch Box
Small Offices Residence
Power InputCurrent InputEERIndoor Temp.Outdoor Temp.
Power InputCurrent InputCOPIndoor Temp.Outdoor Temp.Total CapacityModel / Quantity
*1,*2 Nominal conditions
*3 Up to P100 when connecting via branch box. *4 Up to 11 units when connecting via 2 branch boxes*5 10 to 52°C D.B.: When connecting PKFY-P15/20/25VBM, PFFY-P20/25/32VKM and PFFY-P20/25/32VLE(R)M, PEFY-P-VMA3, M, S and P series indoor unit.*6 Liquid pipe diameter: 12.7mm when piping length is more than 60m.
0.003
0.05
170 - 450 - 280
9.52
15.88
3-wire + Earth wire
3-wire + Earth wire
Flared Brazed
7.4
6.35 × 5
9.52 × 4, 12.7 × 1
6.7
6.35 × 3
9.52 × 3
PAC-MK52BCB
Max. 5
PAC-MK32BCB
Max. 3
7.0
6.35 × 5
9.52 × 4, 12.7 × 1
6.5
6.35 × 3
9.52 × 3
Branch Box
PUMY-P112/125/140V(Y)KM3(-BS)PUMY-P200YKM1(-BS)
Refrigerant Piping Diameter
107
Indoor Unit Compatibility Table
Indoor Unit
Outdoor Unit Inverter Models Heat pump type
MXZ-2D33VA
*3 *3 *3 *3 *3 *3 *3 *3 *3 *3MXZ-
2D42VA2MXZ-
2D53VA(H)2
*3 *3MXZ-
2E53VAHZMXZ-
3E54VAMXZ-
2DM40VAMXZ-
3DM50VAMXZ-
3E68VAMXZ-
4E83VA
*3MXZ-
4E83VAHZMXZ-
5E102VAMXZ-
4E72VAMXZ-
6D122VA
M series Wall-Mounted
S series 2×2Cassette
P series 4-wayCassette
Ceiling-Suspended
Ceiling-Concealed
Ceiling-Concealed
Floor-Standing
1-wayCassette
MSZ-FH25VE2
MSZ-FH35VE2
MSZ-FH50VE2
MSZ-SF15VA
MSZ-SF20VA
MSZ-SF25VE3
MSZ-SF35VE3
MSZ-SF42VE3
MSZ-SF50VE3
MSZ-GF60VE2
MSZ-GF71VE2
MFZ-KJ25VE2
MFZ-KJ35VE2
MFZ-KJ50VE2
MLZ-KA25VA
MLZ-KA35VA
MLZ-KA50VA
SLZ-KF25VA2
SLZ-KF35VA2
SLZ-KF50VA2
SEZ-KD25VAQ
SEZ-KD25VAL
SEZ-KD35VAQ
SEZ-KD35VAL
SEZ-KD50VAQ
SEZ-KD50VAL
SEZ-KD60VAQ
SEZ-KD60VAL
SEZ-KD71VAQ
SEZ-KD71VAL
PLA-RP50EA
PLA-RP60EA
PLA-RP71EA
PCA-RP50KAQ
PCA-RP60KAQ
PCA-RP71KAQ
PEAD-RP50JAQ
PEAD-RP50JALQ
PEAD-RP60JAQ
PEAD-RP60JALQ
PEAD-RP71JAQ
PEAD-RP71JALQ
Possible combinations of outdoor units and indoor units are shown below.
*1 Maximum total current of indoor units: 3A or less.*2 SEZ-KD25 cannot be connected with MXZ-2D(E)/3E/4E/5E when total capacity of connected indoor units is equivalent to outdoor capacity (capacity ratio is 1).*3 MXZ outdoor units are not designed to operate with a single indoor unit with one-to-one piping work. Please install at least two indoor units.*4 When connecting the MFZ-KJ Series indoor unit, additional refrigerant is required. For details, please refer to page 102. *5 Regarding MXZ-2D33, the second unit should be a different type in the case of selecting one MFZ-KJ.*6 P series cannot be connected with MXZ-4E83VAHZ when ampere limit adjustment function is operated.
*1 Authorized connectable indoor units are as follows; PUMY-P112:PEFY-P25×2+P32×2, PUMY-P125:PEFY-P32×4, PUMY-P140:PEFY-P32×3+P40×1, PUMY-P200YKM:PEFY-P40×2+P63×2*2 Note that connection is not allowed inside EU countries. PWFY can not connect to PUMY-P200YKM1.*3 Do not connect Lossnay remote controller(s). (PZ-61DR-E, PZ-60DR-E, PZ-52SF-E, PZ-43SMF-E)
*1*1*1*1*1*1
*2
*2
*1*1*1*1*1*1
*1*1*1
*1*1*1
*1*1*1
*1*1
*6
*6
*6
*6
*6
*1
*4*5 *4
*4
*4
*4
MSZ-LN35VG(W)(V)(R)(B)
MSZ-LN25VG(W)(V)(R)(B)
MSZ-EF18VE3(W)(B)(S)
MSZ-EF22VE3(W)(B)(S)
MSZ-EF25VE3(W)(B)(S)
MSZ-EF35VE3(W)(B)(S)
MSZ-EF42VE3(W)(B)(S)
MSZ-EF50VE3(W)(B)(S)
*4
*4
*4
*4
*4
*4
*1*6
*1*6
*1*6
*1*6
*1*6
*1*6
MSZ-HJ25VA
MSZ-HJ35VA
MSZ-DM25VA
MSZ-DM35VA
MSZ-HJ50VA
Series Type Model NameCapacity
15 18 20 22 25 35 42 50 60 71 100
M series Wall-Mounted
S series
2×2 Cassette
P series
4-way Cassette
Ceiling-Suspended
Ceiling-Concealed
Ceiling-Concealed
Floor-Standing
1-way Cassette
MSZ-GF•VE2
MFZ-KJ•VE2
MLZ-KA•VA
SLZ-KF•VA2
SEZ-KD•VAQ(L)
PLA-RP•EA
PCA-RP•KAQ
PEAD-RP•JA(L)Q
Branch Box Connection Compatibility Table
MSZ-SF•VE3
MSZ-SF•VA
MSZ-EF•VE3
MSZ-FH•VE2
Series Type Model NameCapacity
P15 P20 P25 P32 P40 P50 P63 P71 P80 P100 P140
CITYMULTIseries
1-way Cassette
2-way Cassette
4-way Cassette
2×2 Cassette
Ceiling Concealed
Ceiling Suspended
Wall Mounted
Floor StandingFloor Mounted Concealed
Air to Water unit
Lossnay
CITY MULTI Indoor Unit Compatibility Table
PMFY-P•VBM-E
PLFY-P•VLMD-E
PLFY-P•VEM-E
PLFY-P•VFM-E1
PEFY-P•VMS1(L)-E
PEFY-P•VMA(L)-E
PEFY-P•VMA3-E*1
PEFY-P•VMH-E
PEFY-P•VMR-E-L/R
PEFY-P•VMH-E-F
PCFY-P•VKM-E
PKFY-P•VBM-E
PKFY-P•VHM-E
PKFY-P•VKM-E
PFFY-P•VLEM-E
PFFY-P•VKM-E2
PFFY-P•VLRM-E
PFFY-P•VLRMM-E
PWFY-P•VM-E1/E2-AU*2
GUF-•RD(H)4*3
P125
Series I/U Type Model NameCapacity
15 18 20 22 25 35 42 50 60 71
M series Wall-Mounted
Floor-Standing MFZ-KJ•VE2
LEV Kit Connection Compatibility Table
MSZ-SF•VE3
MSZ-SF•VA
MSZ-EF•VE3
MSZ-FH•VE2
� MXZ Series � PUMY Series
108
Indoor Unit Compatibility Table
Indoor Unit
Outdoor Unit Inverter Models Heat pump type
MXZ-2D33VA
*3 *3 *3 *3 *3 *3 *3 *3 *3 *3MXZ-
2D42VA2MXZ-
2D53VA(H)2
*3 *3MXZ-
2E53VAHZMXZ-
3E54VAMXZ-
2DM40VAMXZ-
3DM50VAMXZ-
3E68VAMXZ-
4E83VA
*3MXZ-
4E83VAHZMXZ-
5E102VAMXZ-
4E72VAMXZ-
6D122VA
M series Wall-Mounted
S series 2×2Cassette
P series 4-wayCassette
Ceiling-Suspended
Ceiling-Concealed
Ceiling-Concealed
Floor-Standing
1-wayCassette
MSZ-FH25VE2
MSZ-FH35VE2
MSZ-FH50VE2
MSZ-SF15VA
MSZ-SF20VA
MSZ-SF25VE3
MSZ-SF35VE3
MSZ-SF42VE3
MSZ-SF50VE3
MSZ-GF60VE2
MSZ-GF71VE2
MFZ-KJ25VE2
MFZ-KJ35VE2
MFZ-KJ50VE2
MLZ-KA25VA
MLZ-KA35VA
MLZ-KA50VA
SLZ-KF25VA2
SLZ-KF35VA2
SLZ-KF50VA2
SEZ-KD25VAQ
SEZ-KD25VAL
SEZ-KD35VAQ
SEZ-KD35VAL
SEZ-KD50VAQ
SEZ-KD50VAL
SEZ-KD60VAQ
SEZ-KD60VAL
SEZ-KD71VAQ
SEZ-KD71VAL
PLA-RP50EA
PLA-RP60EA
PLA-RP71EA
PCA-RP50KAQ
PCA-RP60KAQ
PCA-RP71KAQ
PEAD-RP50JAQ
PEAD-RP50JALQ
PEAD-RP60JAQ
PEAD-RP60JALQ
PEAD-RP71JAQ
PEAD-RP71JALQ
Possible combinations of outdoor units and indoor units are shown below.
*1 Maximum total current of indoor units: 3A or less.*2 SEZ-KD25 cannot be connected with MXZ-2D(E)/3E/4E/5E when total capacity of connected indoor units is equivalent to outdoor capacity (capacity ratio is 1).*3 MXZ outdoor units are not designed to operate with a single indoor unit with one-to-one piping work. Please install at least two indoor units.*4 When connecting the MFZ-KJ Series indoor unit, additional refrigerant is required. For details, please refer to page 102. *5 Regarding MXZ-2D33, the second unit should be a different type in the case of selecting one MFZ-KJ.*6 P series cannot be connected with MXZ-4E83VAHZ when ampere limit adjustment function is operated.
*1 Authorized connectable indoor units are as follows; PUMY-P112:PEFY-P25×2+P32×2, PUMY-P125:PEFY-P32×4, PUMY-P140:PEFY-P32×3+P40×1, PUMY-P200YKM:PEFY-P40×2+P63×2*2 Note that connection is not allowed inside EU countries. PWFY can not connect to PUMY-P200YKM1.*3 Do not connect Lossnay remote controller(s). (PZ-61DR-E, PZ-60DR-E, PZ-52SF-E, PZ-43SMF-E)
*1*1*1*1*1*1
*2
*2
*1*1*1*1*1*1
*1*1*1
*1*1*1
*1*1*1
*1*1
*6
*6
*6
*6
*6
*1
*4*5 *4
*4
*4
*4
MSZ-LN35VG(W)(V)(R)(B)
MSZ-LN25VG(W)(V)(R)(B)
MSZ-EF18VE3(W)(B)(S)
MSZ-EF22VE3(W)(B)(S)
MSZ-EF25VE3(W)(B)(S)
MSZ-EF35VE3(W)(B)(S)
MSZ-EF42VE3(W)(B)(S)
MSZ-EF50VE3(W)(B)(S)
*4
*4
*4
*4
*4
*4
*1*6
*1*6
*1*6
*1*6
*1*6
*1*6
MSZ-HJ25VA
MSZ-HJ35VA
MSZ-DM25VA
MSZ-DM35VA
MSZ-HJ50VA
Series Type Model NameCapacity
15 18 20 22 25 35 42 50 60 71 100
M series Wall-Mounted
S series
2×2 Cassette
P series
4-way Cassette
Ceiling-Suspended
Ceiling-Concealed
Ceiling-Concealed
Floor-Standing
1-way Cassette
MSZ-GF•VE2
MFZ-KJ•VE2
MLZ-KA•VA
SLZ-KF•VA2
SEZ-KD•VAQ(L)
PLA-RP•EA
PCA-RP•KAQ
PEAD-RP•JA(L)Q
Branch Box Connection Compatibility Table
MSZ-SF•VE3
MSZ-SF•VA
MSZ-EF•VE3
MSZ-FH•VE2
Series Type Model NameCapacity
P15 P20 P25 P32 P40 P50 P63 P71 P80 P100 P140
CITYMULTIseries
1-way Cassette
2-way Cassette
4-way Cassette
2×2 Cassette
Ceiling Concealed
Ceiling Suspended
Wall Mounted
Floor StandingFloor Mounted Concealed
Air to Water unit
Lossnay
CITY MULTI Indoor Unit Compatibility Table
PMFY-P•VBM-E
PLFY-P•VLMD-E
PLFY-P•VEM-E
PLFY-P•VFM-E1
PEFY-P•VMS1(L)-E
PEFY-P•VMA(L)-E
PEFY-P•VMA3-E*1
PEFY-P•VMH-E
PEFY-P•VMR-E-L/R
PEFY-P•VMH-E-F
PCFY-P•VKM-E
PKFY-P•VBM-E
PKFY-P•VHM-E
PKFY-P•VKM-E
PFFY-P•VLEM-E
PFFY-P•VKM-E2
PFFY-P•VLRM-E
PFFY-P•VLRMM-E
PWFY-P•VM-E1/E2-AU*2
GUF-•RD(H)4*3
P125
Series I/U Type Model NameCapacity
15 18 20 22 25 35 42 50 60 71
M series Wall-Mounted
Floor-Standing MFZ-KJ•VE2
LEV Kit Connection Compatibility Table
MSZ-SF•VE3
MSZ-SF•VA
MSZ-EF•VE3
MSZ-FH•VE2
� MXZ Series � PUMY Series