99

SERIES

SELECTIONChoose from five types of indoor units and twelve outdoor units that can run up to six indoor units each. Create the system that best matches room shapes and number of rooms.

MULTISPLIT

SELECT INDOOR UNITSSelect the indoor unit to be installed in each room.

Wall-mounted Floor-standing Cassette Ceiling-suspended

Ceiling-concealed

SELECT OUTDOOR UNITSSelect the best outdoor unit based on the number of indoor units and overall system capacity required.

2-port up to 2 indoor units 3-port up to 3 indoor units 4-port up to 4 indoor units

5-port up to 5 indoor units 6-port up to 6 indoor units 4-port up to 4 indoor units

CHECK SYSTEM COMPATIBILITYPossible combinations depends on the outdoor unit chosen. Please check the following points.

Refer to the “Indoor Unit Compatibility Table” to check if the indoor units selected can be used with the outdoor unit selected. (Indoor units not listed in the table cannot be used.)

Refer to the “Combination Table” to check if the capacity combination of the indoor unit selected is connectable. (Combinations not listed cannot be connected.)

Check Indoor Unit CapacityCombination

If the desired combination cannot be found, please change either the indoor or outdoor unit to match one of the combinations shown in the tables.

Check Indoor Units

MXZ-2D33VAMXZ-2D42VA2MXZ-2D53VA(H)2

MXZ-5E102VA MXZ-6D122VA

MXZ-3E54VAMXZ-3E68VA

MXZ-4E72VA MXZ-4E83VA

STEP 1

STEP 2

STEP 3

MXZ-4E83VAHZ

2-port up to 2 indoor units

MXZ-2E53VAHZ

MSZ-FH

MSZ-LN (25•35)

MSZ-EF MSZ-GF

MSZ-SF (25-50)MFZ-KJ

SLZ-KF

PLA

MLZ-KA

PCA

SEZ-KD

PEAD

HYPER HEATING*

*Refer to page105 and page 113 for detailed information.

MSZ-SF (15 •20)

100

SERIES

SELECTIONChoose from five types of indoor units and twelve outdoor units that can run up to six indoor units each. Create the system that best matches room shapes and number of rooms.

MULTISPLIT

SELECT INDOOR UNITSSelect the indoor unit to be installed in each room.

Wall-mounted Floor-standing Cassette Ceiling-suspended

Ceiling-concealed

SELECT OUTDOOR UNITSSelect the best outdoor unit based on the number of indoor units and overall system capacity required.

2-port up to 2 indoor units 3-port up to 3 indoor units 4-port up to 4 indoor units

5-port up to 5 indoor units 6-port up to 6 indoor units 4-port up to 4 indoor units

CHECK SYSTEM COMPATIBILITYPossible combinations depends on the outdoor unit chosen. Please check the following points.

Refer to the “Indoor Unit Compatibility Table” to check if the indoor units selected can be used with the outdoor unit selected. (Indoor units not listed in the table cannot be used.)

Refer to the “Combination Table” to check if the capacity combination of the indoor unit selected is connectable. (Combinations not listed cannot be connected.)

Check Indoor Unit CapacityCombination

If the desired combination cannot be found, please change either the indoor or outdoor unit to match one of the combinations shown in the tables.

Check Indoor Units

MXZ-2D33VAMXZ-2D42VA2MXZ-2D53VA(H)2

MXZ-5E102VA MXZ-6D122VA

MXZ-3E54VAMXZ-3E68VA

MXZ-4E72VA MXZ-4E83VA

STEP 1

STEP 2

STEP 3

MXZ-4E83VAHZ

2-port up to 2 indoor units

MXZ-2E53VAHZ

MSZ-FH

MSZ-LN (25•35)

MSZ-EF MSZ-GF

MSZ-SF (25-50)MFZ-KJ

SLZ-KF

PLA

MLZ-KA

PCA

SEZ-KD

PEAD

HYPER HEATING*

*Refer to page105 and page 113 for detailed information.

MSZ-SF (15 •20)

101

MXZ SERIESAdvancements in the MXZ Series include efficiency and flexibility in system expansion capabilities. The best solution when requiring multi-system air conditioning needs.

OutdoorUnit

EXAMPLE SYSTEM

Handle Up to 6 Rooms with a Single Outdoor Unit

Wiring/Piping Correction Function* (3E54/3E68/4E72/4E83/5E102/6D122)

Support Functions

The MXZ Series offers a nine-system line-up to choose from, ranging between 3.3 and 12.2kW. All of them are compatible with specific M, S and P series indoor units. A single outdoor unit can handle a wide range of building layouts.

2-port 3-port 4-port 4-port 5-port 6-port

MXZ-2D33VAMXZ-2D42VA2MXZ-2D53VA(H)2

MXZ-4E83VAMXZ-5E102VA

MXZ-3E54VAMXZ-3E68VAMXZ-4E72VA

MXZ-6D122VA

MXZ-6D122VA system

Simply press a single button to confirm if wiring and piping are prop-erly connected. Wiring errors are corrected automatically when dis-covered. This eliminates the need to confirm complicated wiring connections when expanding the system. (For details, refer to the outdoor unit installation manual.)* Function cannot be used when the outdoor temperature is below 0°C.

The correction process requires 10–20 minutes to complete and must be conducted with the unit set to the “Cooling” mode.

Ampere Limit Adjustment*(4E83/5E102/6D122)

Dipswitch settings can be used to adjust the maximum electrical current for operation. This function is highly recommended for man-aging energy costs. (For details, refer to the outdoor unit installation manual.)* Maximum capacity is lowered with the use of this function.

Operation Lock

To accommodate specific use applications, cooling or heating opera-tion can be specified when setting the control board of the outdoor unit. A convenient option when a system needs to be configured for exclusive cooling or heating service. (For details, refer to the outdoor unit installation manual.)

Wiringconfirmation

is timeconsuming.

The outdoor unit matches

pipes and wiring.

MXZ-6D122VA

2D-4E83

Up to 2 Indoor Units

Cooling

Heating(Average Season)

Max. Operating Current (Indoor+Outdoor)

Outdoor Unit

Ext. Piping

Guaranteed Operating Range [Outdoor]

SourceOutdoor (V/Phase/Hz)Capacity

Input (Indoor+Outdoor)Design LoadAnnual Electricity Consumption*2

SEER*4

Capacity

Input (Indoor+Outdoor)Design LoadDeclaredCapacity

Back Up Heating CapacityAnnual Electricity Consumption*2

SCOP*4

DimensionsWeightAir Volume

Sound Level (SPL)

Sound Level (PWL)Breaker SizeDiameter

Total Piping Length (max)Each Indoor Unit Piping Length (max)

Rated

Min - Max

Rated

Energy Efficiency Class*4

Rated

Min - Max

Rated

at reference design temperature

at bivalent temperature

at operation limit temperature

Energy Efficiency Class*4

H × W × D 550 - 800 (+69) - 285 (+59.5) 710 - 840 (+30) - 330 (+66) 796 - 950 - 330

Cooling

Heating

Cooling

Cooling

Heating

Liquid

Cooling

Heating

kW

kW

kW

kW

kWh/a

kW

kW

kW

kW

kW

kW

kW

kW

kWh/a

A

mm

kg

m3/min

m3/min

dB(A)

dB(A)

dB(A)

A

mm

Gas mm

m

m

Max. Height m

Chargeless Length moCoC

R410A*1

Outdoor power supply

230 / Single / 50

Please refer to (*4)N: MXZ-2D33VA N: MXZ-2D42VA2 N: MXZ-2D53VA2 N: MXZ-2D53VAH2 N: MXZ-3E54VA N: MXZ-3E68VA N: MXZ-4E72VA MXZ-4E83VA MXZ-5E102VA

Type (Inverter Multi - Split Heat Pump)Indoor Unit

Outdoor Unit

Refrigerant

Power Supply

3.3

1.1 - 3.8

0.90

3.3

211

5.5

A

4.0

1.0 - 4.1

0.96

2.7

2.1

2.4

1.7

0.6

926

4.1

A+

10.0

32

32.9

33.7

49

50

63

10

6.35 × 2

9.52 × 2

20

15

10

20

–10 ~ +46

–15 ~ +24

4.2

1.1 - 4.4

1.00

4.2

216

6.8

A++

4.5

1.0 - 4.8

0.93

3.2

2.7

3.0

2.3

0.5

1065

4.2

A+

12.2

37

27.7

33.3

46

51

60

15

6.35 × 2

9.52 × 2

30

20

15 (10)*3

20

–10 ~ +46

–15 ~ +24

5.3

1.1 - 5.6

1.54

5.3

262

7.1

A++

6.4

1.0 - 7.0

1.70

4.5

3.7

4.0

3.3

0.8

1507

4.2

A+

12.2

37

32.9

33.3

50

53

64

15

6.35 × 2

9.52 × 2

30

20

15 (10)*3

20

–10 ~ +46

–15 ~ +24

5.3

1.1 - 5.6

1.54

5.3

262

7.1

A++

6.4

1.0 - 7.0

1.70

4.5

3.6

4.0

3.0

0.9

1546

4.1

A+

12.2

38

32.9

33.3

50

53

64

15

6.35 × 2

9.52 × 2

30

20

15 (10)*3

20

–10 ~ +46

–20 ~ +24

5.4

2.9 - 6.8

1.35

5.4

295

6.4

A++

7.0

2.6 - 9.0

1.59

5.0

4.0

4.49

3.17

1.0

1751

4.0

A+

18.0

58

42.1

43.0

50

53

64

25

6.35 x 3

9.52 x 3

50

25

15 (10)*3

40

–10 ~ +46

–15 ~ +24

6.8

2.9 - 8.4

2.19

6.8

425

5.6

A+

8.6

2.6 - 10.6

2.38

6.8

5.4

6.0

4.4

1.4

2466

3.9

A

18.0

58

42.1

43.0

50

53

64

25

6.35 x 3

9.52 x 3

60

25

15 (10)*3

40

–10 ~ +46

–15 ~ +24

7.2

3.7 - 8.8

2.25

7.2

443

5.7

A+

8.6

3.4 - 10.7

2.28

7.0

5.6

6.2

4.7

1.4

2516

3.9

A

18.0

59

42.1

43.0

50

53

64

25

6.35 x 4

12.7×1+9.52×3

60

25

15 (10)*3

40

–10 ~ +46

–15 ~ +24

8.3

3.7 - 9.2

2.44

8.3

460

6.3

A++

9.3

3.4 - 11.6

2.00

8.7

7.1

7.8

6.0

1.6

2889

4.2

A+

21.4

63

55.6

55.6

49

51

61

25

6.35 × 4

12.7×1+9.52×3

70

25

15 (10)*3

25

–10 ~ +46

–15 ~ +24

10.2

3.9 - 11.0

3.15

10.2

537

6.6

A++

10.5

4.1 - 14.0

2.34

8.9

7.3

7.9

6.3

1.6

2958

4.2

A+

21.4

64

65.1

68.0

52

56

65

25

6.35 × 5

12.7×1+9.52×4

80

25

15 (10)*3

0

–10 ~ +46

–15 ~ +24

Up to 3 Indoor Units Up to 4 Indoor Units Up to 5 Indoor Units

Up to 6 Indoor Units

Cooling

Heating

Operating Current (max)*5

Outdoor Unit

Ext. Piping

Guaranteed Operating Range [Outdoor]

SourceOutdoor (V/Phase/Hz)Capacity

Input*5

EER*6

Capacity

Input*5

COP*6

DimensionsWeightAir Volume

Sound Level (SPL)

Sound Level (PWL)Breaker SizeDiameter

Total Piping Length (max)Each Indoor Unit Piping Length (max)

Rated

Rated

EEL RankRated

Rated

EEL Rank

H × W × D

Cooling

Heating

Cooling

Cooling

Heating

Liquid

Cooling

Heating

kW

kW

Min - Max kW

kW

Min - Max kW

kW

A

mm

kg

m3/min

m3/min

dB(A)

dB(A)

dB(A)

A

mm

Gas mm

m

m

Max. Height m

Chargeless Length moCoC

R410A*1

Outdoor power supply

230 / Single / 50

Please refer to (*5)

MXZ-6D122VA

Type (Inverter Multi - Split Heat Pump)Indoor Unit

Outdoor Unit

Refrigerant

Power Supply

12.2

3.5 - 13.5

3.66

3.33

A

14.0

3.5 - 16.5

3.31

4.23

A

26.8

1048 -950 -330

88

63.0

77.0

55

57

69

32

6.35×6

12.7×1+9.52×5

80

25

15 (10)*3

30

–10 ~ +46

–15 ~ +24

*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.

*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.*3 If the outdoor unit is installed higher than the indoor unit, max. height is reduced to 10m.*4 EER/COP, EEL rank, SEER/SCOP values and energy efficiency class are measured

when connected to the indoor units listed below.MXZ-2D33VA MSZ-SF15VA + MSZ-EF18VEMXZ-2D42VA2 MSZ-EF18VE + MSZ-EF25VEMXZ-2D53VA(H)2 MSZ-EF18VE + MSZ-EF35VEMXZ-3E54VA MSZ-EF18VE + MSZ-EF18VE + MSZ-EF18VEMXZ-3E68VA MSZ-EF18VE + MSZ-EF25VE + MSZ-EF25VEMXZ-4E72VA MSZ-EF18VE + MSZ-EF18VE + MSZ-EF18VE + MSZ-EF18VEMXZ-4E83VA MSZ-EF18VE + MSZ-EF18VE + MSZ-EF22VE + MSZ-EF25VEMXZ-5E102VA MSZ-EF18VE + MSZ-EF18VE + MSZ-EF22VE + MSZ-EF22VE + MSZ-EF22VE

*5 Power input and operating current (max) figures are for outdoor unit only*6 EER/COP, EEL rank, values and energy efficiency class are measured

when connected to the indoor units listed below.MXZ-6D122VA MSZ-EF22VE × 6

N: Please refer to the NOTE below.

INVERTER MULTIMXZ SERIES

Please fill out the requested informationPlease fill out the requested information

NOTEWhen connecting the MFZ-KJ series indoor unit(s) to this outdoor unit, charge additional refrigerant according to the instructions in the diagram below.

MXZ-2D33VA

No. ofMFZ-KJ indoor units

Maximum amountof refrigerant

Pipe length (L)

~20m

100g additional (Total 1250g)1 unit

2 units

1250g

MXZ-2D42VA2 MXZ-2D53VA2 MXZ-2D53VAH2

No. ofMFZ-KJ indoor units

Maximum amountof refrigerant

Pipe length (L)

~20m

100g additional (Total 1400g)

200g additional (Total 1500g)

~30m

100g+{(L-20)m×20g/m)}

200g+{(L-20)m×20g/m)}

1 unit

2 units

1600g

1700g

MXZ-3E54VA

No. ofMFZ-KJ indoor units

Maximum amountof refrigerant

Pipe length (L)

~40m

100g additional (Total 2800g)

200g additional (Total 2900g)

300g additional (Total 3000g)

~50m

100g+{(L-40)m×20g/m)}

200g+{(L-40)m×20g/m)}

300g+{(L-40)m×20g/m)}

1 unit

2 units

3 units

3000g

3100g

3200g

MXZ-3E68VA MXZ-4E72VA

No. ofMFZ-KJ indoor units

Maximum amountof refrigerant

Pipe length (L)

~40m

100g additional (Total 2800g)

200g additional (Total 2900g)

300g additional (Total 3000g)

~60m

100g+{(L-40)m×20g/m)}

200g+{(L-40)m×20g/m)}

300g+{(L-40)m×20g/m)}

1 unit

2 units

3 units

3200g

3300g

3400g

Not available (Only one MFZ-KJ series indoor unit can be connected.)

MSZ-FH

MLZ-KA

MSZ-SF

MSZ-EF

SLZ-KF

MFZ-KJ

4E83-6D 3D-4D72

102

MXZ SERIESAdvancements in the MXZ Series include efficiency and flexibility in system expansion capabilities. The best solution when requiring multi-system air conditioning needs.

OutdoorUnit

EXAMPLE SYSTEM

Handle Up to 6 Rooms with a Single Outdoor Unit

Wiring/Piping Correction Function* (3E54/3E68/4E72/4E83/5E102/6D122)

Support Functions

The MXZ Series offers a nine-system line-up to choose from, ranging between 3.3 and 12.2kW. All of them are compatible with specific M, S and P series indoor units. A single outdoor unit can handle a wide range of building layouts.

2-port 3-port 4-port 4-port 5-port 6-port

MXZ-2D33VAMXZ-2D42VA2MXZ-2D53VA(H)2

MXZ-4E83VAMXZ-5E102VA

MXZ-3E54VAMXZ-3E68VAMXZ-4E72VA

MXZ-6D122VA

MXZ-6D122VA system

Simply press a single button to confirm if wiring and piping are prop-erly connected. Wiring errors are corrected automatically when dis-covered. This eliminates the need to confirm complicated wiring connections when expanding the system. (For details, refer to the outdoor unit installation manual.)* Function cannot be used when the outdoor temperature is below 0°C.

The correction process requires 10–20 minutes to complete and must be conducted with the unit set to the “Cooling” mode.

Ampere Limit Adjustment*(4E83/5E102/6D122)

Dipswitch settings can be used to adjust the maximum electrical current for operation. This function is highly recommended for man-aging energy costs. (For details, refer to the outdoor unit installation manual.)* Maximum capacity is lowered with the use of this function.

Operation Lock

To accommodate specific use applications, cooling or heating opera-tion can be specified when setting the control board of the outdoor unit. A convenient option when a system needs to be configured for exclusive cooling or heating service. (For details, refer to the outdoor unit installation manual.)

Wiringconfirmation

is timeconsuming.

The outdoor unit matches

pipes and wiring.

MXZ-6D122VA

2D-4E83

Up to 2 Indoor Units

Cooling

Heating(Average Season)

Max. Operating Current (Indoor+Outdoor)

Outdoor Unit

Ext. Piping

Guaranteed Operating Range [Outdoor]

SourceOutdoor (V/Phase/Hz)Capacity

Input (Indoor+Outdoor)Design LoadAnnual Electricity Consumption*2

SEER*4

Capacity

Input (Indoor+Outdoor)Design LoadDeclaredCapacity

Back Up Heating CapacityAnnual Electricity Consumption*2

SCOP*4

DimensionsWeightAir Volume

Sound Level (SPL)

Sound Level (PWL)Breaker SizeDiameter

Total Piping Length (max)Each Indoor Unit Piping Length (max)

Rated

Min - Max

Rated

Energy Efficiency Class*4

Rated

Min - Max

Rated

at reference design temperature

at bivalent temperature

at operation limit temperature

Energy Efficiency Class*4

H × W × D 550 - 800 (+69) - 285 (+59.5) 710 - 840 (+30) - 330 (+66) 796 - 950 - 330

Cooling

Heating

Cooling

Cooling

Heating

Liquid

Cooling

Heating

kW

kW

kW

kW

kWh/a

kW

kW

kW

kW

kW

kW

kW

kW

kWh/a

A

mm

kg

m3/min

m3/min

dB(A)

dB(A)

dB(A)

A

mm

Gas mm

m

m

Max. Height m

Chargeless Length moCoC

R410A*1

Outdoor power supply

230 / Single / 50

Please refer to (*4)N: MXZ-2D33VA N: MXZ-2D42VA2 N: MXZ-2D53VA2 N: MXZ-2D53VAH2 N: MXZ-3E54VA N: MXZ-3E68VA N: MXZ-4E72VA MXZ-4E83VA MXZ-5E102VA

Type (Inverter Multi - Split Heat Pump)Indoor Unit

Outdoor Unit

Refrigerant

Power Supply

3.3

1.1 - 3.8

0.90

3.3

211

5.5

A

4.0

1.0 - 4.1

0.96

2.7

2.1

2.4

1.7

0.6

926

4.1

A+

10.0

32

32.9

33.7

49

50

63

10

6.35 × 2

9.52 × 2

20

15

10

20

–10 ~ +46

–15 ~ +24

4.2

1.1 - 4.4

1.00

4.2

216

6.8

A++

4.5

1.0 - 4.8

0.93

3.2

2.7

3.0

2.3

0.5

1065

4.2

A+

12.2

37

27.7

33.3

46

51

60

15

6.35 × 2

9.52 × 2

30

20

15 (10)*3

20

–10 ~ +46

–15 ~ +24

5.3

1.1 - 5.6

1.54

5.3

262

7.1

A++

6.4

1.0 - 7.0

1.70

4.5

3.7

4.0

3.3

0.8

1507

4.2

A+

12.2

37

32.9

33.3

50

53

64

15

6.35 × 2

9.52 × 2

30

20

15 (10)*3

20

–10 ~ +46

–15 ~ +24

5.3

1.1 - 5.6

1.54

5.3

262

7.1

A++

6.4

1.0 - 7.0

1.70

4.5

3.6

4.0

3.0

0.9

1546

4.1

A+

12.2

38

32.9

33.3

50

53

64

15

6.35 × 2

9.52 × 2

30

20

15 (10)*3

20

–10 ~ +46

–20 ~ +24

5.4

2.9 - 6.8

1.35

5.4

295

6.4

A++

7.0

2.6 - 9.0

1.59

5.0

4.0

4.49

3.17

1.0

1751

4.0

A+

18.0

58

42.1

43.0

50

53

64

25

6.35 x 3

9.52 x 3

50

25

15 (10)*3

40

–10 ~ +46

–15 ~ +24

6.8

2.9 - 8.4

2.19

6.8

425

5.6

A+

8.6

2.6 - 10.6

2.38

6.8

5.4

6.0

4.4

1.4

2466

3.9

A

18.0

58

42.1

43.0

50

53

64

25

6.35 x 3

9.52 x 3

60

25

15 (10)*3

40

–10 ~ +46

–15 ~ +24

7.2

3.7 - 8.8

2.25

7.2

443

5.7

A+

8.6

3.4 - 10.7

2.28

7.0

5.6

6.2

4.7

1.4

2516

3.9

A

18.0

59

42.1

43.0

50

53

64

25

6.35 x 4

12.7×1+9.52×3

60

25

15 (10)*3

40

–10 ~ +46

–15 ~ +24

8.3

3.7 - 9.2

2.44

8.3

460

6.3

A++

9.3

3.4 - 11.6

2.00

8.7

7.1

7.8

6.0

1.6

2889

4.2

A+

21.4

63

55.6

55.6

49

51

61

25

6.35 × 4

12.7×1+9.52×3

70

25

15 (10)*3

25

–10 ~ +46

–15 ~ +24

10.2

3.9 - 11.0

3.15

10.2

537

6.6

A++

10.5

4.1 - 14.0

2.34

8.9

7.3

7.9

6.3

1.6

2958

4.2

A+

21.4

64

65.1

68.0

52

56

65

25

6.35 × 5

12.7×1+9.52×4

80

25

15 (10)*3

0

–10 ~ +46

–15 ~ +24

Up to 3 Indoor Units Up to 4 Indoor Units Up to 5 Indoor Units

Up to 6 Indoor Units

Cooling

Heating

Operating Current (max)*5

Outdoor Unit

Ext. Piping

Guaranteed Operating Range [Outdoor]

SourceOutdoor (V/Phase/Hz)Capacity

Input*5

EER*6

Capacity

Input*5

COP*6

DimensionsWeightAir Volume

Sound Level (SPL)

Sound Level (PWL)Breaker SizeDiameter

Total Piping Length (max)Each Indoor Unit Piping Length (max)

Rated

Rated

EEL RankRated

Rated

EEL Rank

H × W × D

Cooling

Heating

Cooling

Cooling

Heating

Liquid

Cooling

Heating

kW

kW

Min - Max kW

kW

Min - Max kW

kW

A

mm

kg

m3/min

m3/min

dB(A)

dB(A)

dB(A)

A

mm

Gas mm

m

m

Max. Height m

Chargeless Length moCoC

R410A*1

Outdoor power supply

230 / Single / 50

Please refer to (*5)

MXZ-6D122VA

Type (Inverter Multi - Split Heat Pump)Indoor Unit

Outdoor Unit

Refrigerant

Power Supply

12.2

3.5 - 13.5

3.66

3.33

A

14.0

3.5 - 16.5

3.31

4.23

A

26.8

1048 -950 -330

88

63.0

77.0

55

57

69

32

6.35×6

12.7×1+9.52×5

80

25

15 (10)*3

30

–10 ~ +46

–15 ~ +24

*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.

*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.*3 If the outdoor unit is installed higher than the indoor unit, max. height is reduced to 10m.*4 EER/COP, EEL rank, SEER/SCOP values and energy efficiency class are measured

when connected to the indoor units listed below.MXZ-2D33VA MSZ-SF15VA + MSZ-EF18VEMXZ-2D42VA2 MSZ-EF18VE + MSZ-EF25VEMXZ-2D53VA(H)2 MSZ-EF18VE + MSZ-EF35VEMXZ-3E54VA MSZ-EF18VE + MSZ-EF18VE + MSZ-EF18VEMXZ-3E68VA MSZ-EF18VE + MSZ-EF25VE + MSZ-EF25VEMXZ-4E72VA MSZ-EF18VE + MSZ-EF18VE + MSZ-EF18VE + MSZ-EF18VEMXZ-4E83VA MSZ-EF18VE + MSZ-EF18VE + MSZ-EF22VE + MSZ-EF25VEMXZ-5E102VA MSZ-EF18VE + MSZ-EF18VE + MSZ-EF22VE + MSZ-EF22VE + MSZ-EF22VE

*5 Power input and operating current (max) figures are for outdoor unit only*6 EER/COP, EEL rank, values and energy efficiency class are measured

when connected to the indoor units listed below.MXZ-6D122VA MSZ-EF22VE × 6

N: Please refer to the NOTE below.

INVERTER MULTIMXZ SERIES

Please fill out the requested informationPlease fill out the requested information

NOTEWhen connecting the MFZ-KJ series indoor unit(s) to this outdoor unit, charge additional refrigerant according to the instructions in the diagram below.

MXZ-2D33VA

No. ofMFZ-KJ indoor units

Maximum amountof refrigerant

Pipe length (L)

~20m

100g additional (Total 1250g)1 unit

2 units

1250g

MXZ-2D42VA2 MXZ-2D53VA2 MXZ-2D53VAH2

No. ofMFZ-KJ indoor units

Maximum amountof refrigerant

Pipe length (L)

~20m

100g additional (Total 1400g)

200g additional (Total 1500g)

~30m

100g+{(L-20)m×20g/m)}

200g+{(L-20)m×20g/m)}

1 unit

2 units

1600g

1700g

MXZ-3E54VA

No. ofMFZ-KJ indoor units

Maximum amountof refrigerant

Pipe length (L)

~40m

100g additional (Total 2800g)

200g additional (Total 2900g)

300g additional (Total 3000g)

~50m

100g+{(L-40)m×20g/m)}

200g+{(L-40)m×20g/m)}

300g+{(L-40)m×20g/m)}

1 unit

2 units

3 units

3000g

3100g

3200g

MXZ-3E68VA MXZ-4E72VA

No. ofMFZ-KJ indoor units

Maximum amountof refrigerant

Pipe length (L)

~40m

100g additional (Total 2800g)

200g additional (Total 2900g)

300g additional (Total 3000g)

~60m

100g+{(L-40)m×20g/m)}

200g+{(L-40)m×20g/m)}

300g+{(L-40)m×20g/m)}

1 unit

2 units

3 units

3200g

3300g

3400g

Not available (Only one MFZ-KJ series indoor unit can be connected.)

MSZ-FH

MLZ-KA

MSZ-SF

MSZ-EF

SLZ-KF

MFZ-KJ

4E83-6D 3D-4D72

103

MXZ-DM SERIESMulti-port outdoor units exclusively for MSZ-HJ and DM indoor units.

2-port 3-port

MXZ-2DM40VA MXZ-3DM50VA

Up to 2 Indoor Units

Cooling

Heating(Average Season)

Operating Current (max)

Outdoor Unit

Ext. Piping

Guaranteed Operating Range [Outdoor]

SourceOutdoor (V/Phase/Hz)

CapacityInput*4

EER*4

SEER*4

Design LoadAnnual Electricity Consumption*2

CapacityInputCOP*4

DeclaredCapacity

Design Load

Back Up Heating CapacityAnnual Electricity Consumption*2

SCOP*4

DimensionsWeightAir Volume

Sound Level (SPL)

Sound Level (PWL)

Breaker SizePort DiameterTotal Piping Length (max)Each Indoor Unit Piping Length (max)

Rated

Rated

EEL Rank*4

Energy Efficiency Class*4

Rated

Rated

EEL Rank*4

at reference design temperature

at bivalent temperature

at operation limit temperature

Energy Efficiency Class*4

H × W × D

Cooling

Heating

Cooling

Cooling

Heating

Liquid / Gas

Cooling

Heating

kW

kW

kW

kWh/a

kW

kW

kW

kW

kW

kW

kW

kWh/a

A

mm

kg

m3/min

m3/min

dB(A)

dB(A)

dB(A)

Operating Current Cooling A

Heating A

A

mm

m

m

Max. Height m

Chargeless Length moCoC

R410A*1

Outdoor power supply

230 / Single / 50

Please refer to (*4)

MXZ-2DM40VA MXZ-3DM50VA

Type (Inverter Multi - Split Heat Pump)Indoor Unit

Outdoor Unit

Refrigerant

Power Supply

4.0

1.05

3.81

A

4.0

226

6.1

A++

4.3

1.16

3.71

A

3.2

2.73

3.01

2.27

0.47

1105

4.0

A+

12.2

550 - 800 (+69) - 285 (+59.5)

32

29.2

31.9

48

52

63

5.1

5.6

15

6.35 × 2 / 9.52 × 2

30

20

15 (10)*3

20

5.0

1.13

4.42

A

5.0

283

6.1

A++

6.0

1.31

4.58

A

4.0

3.34

3.73

2.70

0.66

1455

3.8

A

18.0

710 - 840 (+30) - 330 (+66)

57

37.5

39.6

50

53

64

5.0

5.8

25

6.35 × 3 / 9.52 × 3

50

25

15 (10)*3

40

Up to 3 Indoor Units

*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.

*2 Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.*3 If the outdoor unit is installed higher than the indoor unit, max hight is reduced to 10m.*4 EER/COP, EEL rank, SEER/SCOP values and energy efficiency class are measured when connected to the indoor units listed below.

MXZ-2DM40VA MSZ-DM25VA + MSZ-DM25VA MXZ-3DM50VA MSZ-DM25VA + MSZ-DM25VA + MSZ-DM25VA

INVERTER MULTIMXZ-DM SERIES

Please fill out the requested informationPlease fill out the requested information

Stylish Design with Flat Panel Front

Easy to create various combinations

A stylish flat panel design is employed for the front of the indoor unit. The simple look matches room aesthetics.

Wide range of simple combinations only possible using multi-port outdoor units.

MXZ-DM is exclusively for connection to MSZ-HJ and DM.Please check to make sure that wiring is done correctly.

For MXZ-DMFor MSZ-HJ/DM / MUZ-HJ/DM

S1

MSZ-HJ/DMMXZ-2DMMXZ-3DM

S2 S3 N L

S3 N N~L~L

S1 S2 S3 N L

S1 S2 S3

MSZ-HJ/DMMUZ-HJ/DM

Attention

Two bedrooms Three bedrooms

Living room and one bedroom Wide living room

3HJ

–10 ~ +46

–15 ~ +24

104

MXZ-DM SERIESMulti-port outdoor units exclusively for MSZ-HJ and DM indoor units.

2-port 3-port

MXZ-2DM40VA MXZ-3DM50VA

Up to 2 Indoor Units

Cooling

Heating(Average Season)

Operating Current (max)

Outdoor Unit

Ext. Piping

Guaranteed Operating Range [Outdoor]

SourceOutdoor (V/Phase/Hz)

CapacityInput*4

EER*4

SEER*4

Design LoadAnnual Electricity Consumption*2

CapacityInputCOP*4

DeclaredCapacity

Design Load

Back Up Heating CapacityAnnual Electricity Consumption*2

SCOP*4

DimensionsWeightAir Volume

Sound Level (SPL)

Sound Level (PWL)

Breaker SizePort DiameterTotal Piping Length (max)Each Indoor Unit Piping Length (max)

Rated

Rated

EEL Rank*4

Energy Efficiency Class*4

Rated

Rated

EEL Rank*4

at reference design temperature

at bivalent temperature

at operation limit temperature

Energy Efficiency Class*4

H × W × D

Cooling

Heating

Cooling

Cooling

Heating

Liquid / Gas

Cooling

Heating

kW

kW

kW

kWh/a

kW

kW

kW

kW

kW

kW

kW

kWh/a

A

mm

kg

m3/min

m3/min

dB(A)

dB(A)

dB(A)

Operating Current Cooling A

Heating A

A

mm

m

m

Max. Height m

Chargeless Length moCoC

R410A*1

Outdoor power supply

230 / Single / 50

Please refer to (*4)

MXZ-2DM40VA MXZ-3DM50VA

Type (Inverter Multi - Split Heat Pump)Indoor Unit

Outdoor Unit

Refrigerant

Power Supply

4.0

1.05

3.81

A

4.0

226

6.1

A++

4.3

1.16

3.71

A

3.2

2.73

3.01

2.27

0.47

1105

4.0

A+

12.2

550 - 800 (+69) - 285 (+59.5)

32

29.2

31.9

48

52

63

5.1

5.6

15

6.35 × 2 / 9.52 × 2

30

20

15 (10)*3

20

5.0

1.13

4.42

A

5.0

283

6.1

A++

6.0

1.31

4.58

A

4.0

3.34

3.73

2.70

0.66

1455

3.8

A

18.0

710 - 840 (+30) - 330 (+66)

57

37.5

39.6

50

53

64

5.0

5.8

25

6.35 × 3 / 9.52 × 3

50

25

15 (10)*3

40

Up to 3 Indoor Units

*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.

*2 Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.*3 If the outdoor unit is installed higher than the indoor unit, max hight is reduced to 10m.*4 EER/COP, EEL rank, SEER/SCOP values and energy efficiency class are measured when connected to the indoor units listed below.

MXZ-2DM40VA MSZ-DM25VA + MSZ-DM25VA MXZ-3DM50VA MSZ-DM25VA + MSZ-DM25VA + MSZ-DM25VA

INVERTER MULTIMXZ-DM SERIES

Please fill out the requested informationPlease fill out the requested information

Stylish Design with Flat Panel Front

Easy to create various combinations

A stylish flat panel design is employed for the front of the indoor unit. The simple look matches room aesthetics.

Wide range of simple combinations only possible using multi-port outdoor units.

MXZ-DM is exclusively for connection to MSZ-HJ and DM.Please check to make sure that wiring is done correctly.

For MXZ-DMFor MSZ-HJ/DM / MUZ-HJ/DM

S1

MSZ-HJ/DMMXZ-2DMMXZ-3DM

S2 S3 N L

S3 N N~L~L

S1 S2 S3 N L

S1 S2 S3

MSZ-HJ/DMMUZ-HJ/DM

Attention

Two bedrooms Three bedrooms

Living room and one bedroom Wide living room

3HJ

–10 ~ +46

–15 ~ +24

105

PUMYSERIESAir conditioning system supports replacement work by simplifying the installa-tion process. Ideal for supporting renewal needs at small offices and stores, home offices, etc.

EXAMPLE SYSTEM

The two-pipe zoned system designed for Heat Pump Operation

PUMY series make use of a two-pipe refrigerant system, which allows for system changeover from cooling to heating, ensuring that a constant indoor climate is maintained in all zones. The compact outdoor unit utilizes R410A refrigerant and an INVERTER-driven compressor to use energy effectively.With a wide range of indoor unit line-up in connection with a flexible piping system, PUMY series can be configured for all applications. Up to 12 indoor units can be connected with up to 130% connected capacity to maximize engineer's design options. This feature allows easy air condition-ing in each area with convenient individual controllers.

PUMY-P112/125/140VKM3(-BS)PUMY-P112/125/140YKM3(-BS)PUMY-P200YKM1(-BS)

2D-4D72

Cooling Capacity(nominal)

Temp. Range of Cooling*5

Temp. Range of Heating

Heating Capacity(nominal)

Sound Pressure Level(measured in anechoic room)

Indoor27°C DB / 19°C WB

20°C DB

CoolingHeating

Outdoor35°C

7°C DB / 6°C WB

Piping Length7.5m

7.5m

Level Difference0m

0m

Indoor Unit Connectable

Fan

Compressor

External Dimensions (H × W × D)Weight

Liquid PipeGas PipeType × QuantityAir Flow Rate

Motor OutputType × QuantityStarting MethodMotor Output

mm

mm

m3/min

L/s

cfm

kW

kW

mm

kg

*1

*2

50 to 130% of outdoor unit capacity

9.52 Flare

15.88 Flare

Propeller Fan × 2

110

1,883

3,884

0.074 + 0.074

Scroll hermetic compressor × 1

Inverter

1,338×1,050×330 (+25)

9.52*6 Flare

19.1 Flare

139

2,316

4,908

0.20 + 0.20

137

2.9 3.5

122

3.9 2.9 3.5

125

3.9

kW

kW

A

kW/kW

W.B.

D.B.

kW

kW

A

kW/kW

D.B.

W.B.

City Multi

Branch Box

Mixed System

dB <A>

1-phase 220 - 230 - 240V 50Hz 3-phase 380 - 400 - 415V 50HzModelPower Source

12.5

2.79

12.87 - 12.32 - 11.80

4.48

15.0 - 24.0°C

-5.0 - 52°C

14.0

3.04

14.03 - 13.42 - 12.86

4.61

15.0 - 27.0°C

-20.0 - 15.0°C

15 - 140 / 9

15 - 100 / 8

15 - 140*3/10

49 / 51

14.0

3.46

15.97 - 15.27 - 14.64

4.05

15.0 - 24.0°C

-5.0 - 52°C

16.0

3.74

17.26 - 16.51 - 15.82

4.28

15.0 - 27.0°C

-20.0 - 15.0°C

15 - 140 / 10

15 - 100 / 8

15 - 140*3/10*4

50 / 52

15.5

4.52

20.86 - 19.95 - 19.12

3.43

15.0 - 24.0°C

-5.0 - 52°C

18.0

4.47

20.63 - 19.73 - 18.91

4.03

15.0 - 27.0°C

-20.0 - 15.0°C

15 - 140 / 12

15 - 100 / 8

15 - 140*3/10*4

51 / 53

12.5

2.79

4.99 - 4.74 - 4.57

4.48

15.0 - 24.0°C

-5.0 - 52°C

14.0

3.04

5.43 - 5.16 - 4.98

4.61

15.0 - 27.0°C

-20.0 - 15.0°C

15 - 140 / 9

15 - 100 / 8

15 - 140*3/10

49 / 51

14.0

3.46

5.84 - 5.55 - 5.35

4.05

15.0 - 24.0°C

-5.0 - 52°C

16.0

3.74

6.31 - 6.00 - 5.78

4.28

15.0 - 27.0°C

-20.0 - 15.0°C

15 - 140 / 10

15 - 100 / 8

15 - 140*3/10*4

50 / 52

15.5

4.52

7.23 - 6.87 - 6.62

3.43

15.0 - 24.0°C

-5.0 - 52°C

18.0

4.47

7.15 - 6.79 - 6.55

4.03

15.0 - 27.0°C

-20.0 - 15.0°C

15 - 140 / 12

15 - 100 / 8

15 - 140*3/10*4

51 / 53

PUMY-P140VKM3(-BS) PUMY-P112YKM3(-BS) PUMY-P125YKM3(-BS) PUMY-P140YKM3(-BS)

5.3

22.4

6.05

9.88 - 9.39 - 9.05

3.70

15.0 - 24.0°C

-5.0 - 52°C

25.0

5.84

9.54 - 9.06 - 8.74

4.28

15.0 - 27.0°C

-20.0 - 15.0°C

15 - 200 / 12

15 - 100 / 8

15 - 200*3/10*4

56 / 61

PUMY-P200YKM1(-BS)PUMY-P125VKM3(-BS)PUMY-P112VKM3(-BS)

Branch Box

Total InputOperating CurrentDimensionsWeightPiping[diameter]

Branch[Indoor Side]

Main[Outdoor Side]

Connection Methodto Indoor Unitto Outdoor Unit

Wiring

SourceOutdoor (V/Phase/Hz)

Liquid

Gas

Liquid

Gas

kW

mm

kg

mm

mm

mm

mm

H × W × D

A

PAC-MK52BC

Max. 5Outdoor power supply, Branch Box / Outdoor separate power supply

1-phase, 220 - 230 - 240V, 50Hz

PAC-MK32BC

Max. 3

TypeModel Name

Connectable Number of Indoor Units

Power Supply

INVERTER MULTIPUMY SERIES

MSZ-FH

MFZ-KJ

CITY MULTIindoor unit

Branch Box

MSZ-EF

4D83-6C 3D-5D

Total lengthMaximum allowable lengthFarthest indoor from first branch

300150 (175 equivalent)

30

Outdoor unit

Indoor unitBetweenindoor units top-bottomdifferential15m*

*In case of branch box connection: 12m

Refrigerant Piping Lengths Maximum meters

[P112–140V/YKM3(-BS)]

Furthest piping length 175m (equivalent length) (actual length 150m)

Silent mode can reduce sound pressure level by 3dB(A)

Indoor/outdoor (outdoor higher)Indoor/outdoor (outdoor lower)Indoor/indoor

5040

15*

Vertical differentials between units Maximum meters

Total lengthMaximum allowable lengthFarthest indoor from first branch

1508030

Refrigerant Piping Lengths Maximum meters

[P200YKM1(-BS)]

Indoor/outdoor (outdoor higher)Indoor/outdoor (outdoor lower)Indoor/indoor

5040

15*

Vertical differentials between units Maximum meters

Top-bottom differential 50m

Outdoor unit

Outdoor unit

Branch Box

Small Offices Residence

Power InputCurrent InputEERIndoor Temp.Outdoor Temp.

Power InputCurrent InputCOPIndoor Temp.Outdoor Temp.Total CapacityModel / Quantity

*1,*2 Nominal conditions

*3 Up to P100 when connecting via branch box. *4 Up to 11 units when connecting via 2 branch boxes*5 10 to 52°C D.B.: When connecting PKFY-P15/20/25VBM, PFFY-P20/25/32VKM and PFFY-P20/25/32VLE(R)M, PEFY-P-VMA3, M, S and P series indoor unit.*6 Liquid pipe diameter: 12.7mm when piping length is more than 60m.

0.003

0.05

170 - 450 - 280

9.52

15.88

3-wire + Earth wire

3-wire + Earth wire

Flared Brazed

7.4

6.35 × 5

9.52 × 4, 12.7 × 1

6.7

6.35 × 3

9.52 × 3

PAC-MK52BCB

Max. 5

PAC-MK32BCB

Max. 3

7.0

6.35 × 5

9.52 × 4, 12.7 × 1

6.5

6.35 × 3

9.52 × 3

Branch Box

PUMY-P112/125/140V(Y)KM3(-BS)PUMY-P200YKM1(-BS)

Refrigerant Piping Diameter

106

PUMYSERIESAir conditioning system supports replacement work by simplifying the installa-tion process. Ideal for supporting renewal needs at small offices and stores, home offices, etc.

EXAMPLE SYSTEM

The two-pipe zoned system designed for Heat Pump Operation

PUMY series make use of a two-pipe refrigerant system, which allows for system changeover from cooling to heating, ensuring that a constant indoor climate is maintained in all zones. The compact outdoor unit utilizes R410A refrigerant and an INVERTER-driven compressor to use energy effectively.With a wide range of indoor unit line-up in connection with a flexible piping system, PUMY series can be configured for all applications. Up to 12 indoor units can be connected with up to 130% connected capacity to maximize engineer's design options. This feature allows easy air condition-ing in each area with convenient individual controllers.

PUMY-P112/125/140VKM3(-BS)PUMY-P112/125/140YKM3(-BS)PUMY-P200YKM1(-BS)

2D-4D72

Cooling Capacity(nominal)

Temp. Range of Cooling*5

Temp. Range of Heating

Heating Capacity(nominal)

Sound Pressure Level(measured in anechoic room)

Indoor27°C DB / 19°C WB

20°C DB

CoolingHeating

Outdoor35°C

7°C DB / 6°C WB

Piping Length7.5m

7.5m

Level Difference0m

0m

Indoor Unit Connectable

Fan

Compressor

External Dimensions (H × W × D)Weight

Liquid PipeGas PipeType × QuantityAir Flow Rate

Motor OutputType × QuantityStarting MethodMotor Output

mm

mm

m3/min

L/s

cfm

kW

kW

mm

kg

*1

*2

50 to 130% of outdoor unit capacity

9.52 Flare

15.88 Flare

Propeller Fan × 2

110

1,883

3,884

0.074 + 0.074

Scroll hermetic compressor × 1

Inverter

1,338×1,050×330 (+25)

9.52*6 Flare

19.1 Flare

139

2,316

4,908

0.20 + 0.20

137

2.9 3.5

122

3.9 2.9 3.5

125

3.9

kW

kW

A

kW/kW

W.B.

D.B.

kW

kW

A

kW/kW

D.B.

W.B.

City Multi

Branch Box

Mixed System

dB <A>

1-phase 220 - 230 - 240V 50Hz 3-phase 380 - 400 - 415V 50HzModelPower Source

12.5

2.79

12.87 - 12.32 - 11.80

4.48

15.0 - 24.0°C

-5.0 - 52°C

14.0

3.04

14.03 - 13.42 - 12.86

4.61

15.0 - 27.0°C

-20.0 - 15.0°C

15 - 140 / 9

15 - 100 / 8

15 - 140*3/10

49 / 51

14.0

3.46

15.97 - 15.27 - 14.64

4.05

15.0 - 24.0°C

-5.0 - 52°C

16.0

3.74

17.26 - 16.51 - 15.82

4.28

15.0 - 27.0°C

-20.0 - 15.0°C

15 - 140 / 10

15 - 100 / 8

15 - 140*3/10*4

50 / 52

15.5

4.52

20.86 - 19.95 - 19.12

3.43

15.0 - 24.0°C

-5.0 - 52°C

18.0

4.47

20.63 - 19.73 - 18.91

4.03

15.0 - 27.0°C

-20.0 - 15.0°C

15 - 140 / 12

15 - 100 / 8

15 - 140*3/10*4

51 / 53

12.5

2.79

4.99 - 4.74 - 4.57

4.48

15.0 - 24.0°C

-5.0 - 52°C

14.0

3.04

5.43 - 5.16 - 4.98

4.61

15.0 - 27.0°C

-20.0 - 15.0°C

15 - 140 / 9

15 - 100 / 8

15 - 140*3/10

49 / 51

14.0

3.46

5.84 - 5.55 - 5.35

4.05

15.0 - 24.0°C

-5.0 - 52°C

16.0

3.74

6.31 - 6.00 - 5.78

4.28

15.0 - 27.0°C

-20.0 - 15.0°C

15 - 140 / 10

15 - 100 / 8

15 - 140*3/10*4

50 / 52

15.5

4.52

7.23 - 6.87 - 6.62

3.43

15.0 - 24.0°C

-5.0 - 52°C

18.0

4.47

7.15 - 6.79 - 6.55

4.03

15.0 - 27.0°C

-20.0 - 15.0°C

15 - 140 / 12

15 - 100 / 8

15 - 140*3/10*4

51 / 53

PUMY-P140VKM3(-BS) PUMY-P112YKM3(-BS) PUMY-P125YKM3(-BS) PUMY-P140YKM3(-BS)

5.3

22.4

6.05

9.88 - 9.39 - 9.05

3.70

15.0 - 24.0°C

-5.0 - 52°C

25.0

5.84

9.54 - 9.06 - 8.74

4.28

15.0 - 27.0°C

-20.0 - 15.0°C

15 - 200 / 12

15 - 100 / 8

15 - 200*3/10*4

56 / 61

PUMY-P200YKM1(-BS)PUMY-P125VKM3(-BS)PUMY-P112VKM3(-BS)

Branch Box

Total InputOperating CurrentDimensionsWeightPiping[diameter]

Branch[Indoor Side]

Main[Outdoor Side]

Connection Methodto Indoor Unitto Outdoor Unit

Wiring

SourceOutdoor (V/Phase/Hz)

Liquid

Gas

Liquid

Gas

kW

mm

kg

mm

mm

mm

mm

H × W × D

A

PAC-MK52BC

Max. 5Outdoor power supply, Branch Box / Outdoor separate power supply

1-phase, 220 - 230 - 240V, 50Hz

PAC-MK32BC

Max. 3

TypeModel Name

Connectable Number of Indoor Units

Power Supply

INVERTER MULTIPUMY SERIES

MSZ-FH

MFZ-KJ

CITY MULTIindoor unit

Branch Box

MSZ-EF

4D83-6C 3D-5D

Total lengthMaximum allowable lengthFarthest indoor from first branch

300150 (175 equivalent)

30

Outdoor unit

Indoor unitBetweenindoor units top-bottomdifferential15m*

*In case of branch box connection: 12m

Refrigerant Piping Lengths Maximum meters

[P112–140V/YKM3(-BS)]

Furthest piping length 175m (equivalent length) (actual length 150m)

Silent mode can reduce sound pressure level by 3dB(A)

Indoor/outdoor (outdoor higher)Indoor/outdoor (outdoor lower)Indoor/indoor

5040

15*

Vertical differentials between units Maximum meters

Total lengthMaximum allowable lengthFarthest indoor from first branch

1508030

Refrigerant Piping Lengths Maximum meters

[P200YKM1(-BS)]

Indoor/outdoor (outdoor higher)Indoor/outdoor (outdoor lower)Indoor/indoor

5040

15*

Vertical differentials between units Maximum meters

Top-bottom differential 50m

Outdoor unit

Outdoor unit

Branch Box

Small Offices Residence

Power InputCurrent InputEERIndoor Temp.Outdoor Temp.

Power InputCurrent InputCOPIndoor Temp.Outdoor Temp.Total CapacityModel / Quantity

*1,*2 Nominal conditions

*3 Up to P100 when connecting via branch box. *4 Up to 11 units when connecting via 2 branch boxes*5 10 to 52°C D.B.: When connecting PKFY-P15/20/25VBM, PFFY-P20/25/32VKM and PFFY-P20/25/32VLE(R)M, PEFY-P-VMA3, M, S and P series indoor unit.*6 Liquid pipe diameter: 12.7mm when piping length is more than 60m.

0.003

0.05

170 - 450 - 280

9.52

15.88

3-wire + Earth wire

3-wire + Earth wire

Flared Brazed

7.4

6.35 × 5

9.52 × 4, 12.7 × 1

6.7

6.35 × 3

9.52 × 3

PAC-MK52BCB

Max. 5

PAC-MK32BCB

Max. 3

7.0

6.35 × 5

9.52 × 4, 12.7 × 1

6.5

6.35 × 3

9.52 × 3

Branch Box

PUMY-P112/125/140V(Y)KM3(-BS)PUMY-P200YKM1(-BS)

Refrigerant Piping Diameter

107

Indoor Unit Compatibility Table

Indoor Unit

Outdoor Unit Inverter Models Heat pump type

MXZ-2D33VA

*3 *3 *3 *3 *3 *3 *3 *3 *3 *3MXZ-

2D42VA2MXZ-

2D53VA(H)2

*3 *3MXZ-

2E53VAHZMXZ-

3E54VAMXZ-

2DM40VAMXZ-

3DM50VAMXZ-

3E68VAMXZ-

4E83VA

*3MXZ-

4E83VAHZMXZ-

5E102VAMXZ-

4E72VAMXZ-

6D122VA

M series Wall-Mounted

S series 2×2Cassette

P series 4-wayCassette

Ceiling-Suspended

Ceiling-Concealed

Ceiling-Concealed

Floor-Standing

1-wayCassette

MSZ-FH25VE2

MSZ-FH35VE2

MSZ-FH50VE2

MSZ-SF15VA

MSZ-SF20VA

MSZ-SF25VE3

MSZ-SF35VE3

MSZ-SF42VE3

MSZ-SF50VE3

MSZ-GF60VE2

MSZ-GF71VE2

MFZ-KJ25VE2

MFZ-KJ35VE2

MFZ-KJ50VE2

MLZ-KA25VA

MLZ-KA35VA

MLZ-KA50VA

SLZ-KF25VA2

SLZ-KF35VA2

SLZ-KF50VA2

SEZ-KD25VAQ

SEZ-KD25VAL

SEZ-KD35VAQ

SEZ-KD35VAL

SEZ-KD50VAQ

SEZ-KD50VAL

SEZ-KD60VAQ

SEZ-KD60VAL

SEZ-KD71VAQ

SEZ-KD71VAL

PLA-RP50EA

PLA-RP60EA

PLA-RP71EA

PCA-RP50KAQ

PCA-RP60KAQ

PCA-RP71KAQ

PEAD-RP50JAQ

PEAD-RP50JALQ

PEAD-RP60JAQ

PEAD-RP60JALQ

PEAD-RP71JAQ

PEAD-RP71JALQ

Possible combinations of outdoor units and indoor units are shown below.

*1 Maximum total current of indoor units: 3A or less.*2 SEZ-KD25 cannot be connected with MXZ-2D(E)/3E/4E/5E when total capacity of connected indoor units is equivalent to outdoor capacity (capacity ratio is 1).*3 MXZ outdoor units are not designed to operate with a single indoor unit with one-to-one piping work. Please install at least two indoor units.*4 When connecting the MFZ-KJ Series indoor unit, additional refrigerant is required. For details, please refer to page 102. *5 Regarding MXZ-2D33, the second unit should be a different type in the case of selecting one MFZ-KJ.*6 P series cannot be connected with MXZ-4E83VAHZ when ampere limit adjustment function is operated.

*1 Authorized connectable indoor units are as follows; PUMY-P112:PEFY-P25×2+P32×2, PUMY-P125:PEFY-P32×4, PUMY-P140:PEFY-P32×3+P40×1, PUMY-P200YKM:PEFY-P40×2+P63×2*2 Note that connection is not allowed inside EU countries. PWFY can not connect to PUMY-P200YKM1.*3 Do not connect Lossnay remote controller(s). (PZ-61DR-E, PZ-60DR-E, PZ-52SF-E, PZ-43SMF-E)

*1*1*1*1*1*1

*2

*2

*1*1*1*1*1*1

*1*1*1

*1*1*1

*1*1*1

*1*1

*6

*6

*6

*6

*6

*1

*4*5 *4

*4

*4

*4

MSZ-LN35VG(W)(V)(R)(B)

MSZ-LN25VG(W)(V)(R)(B)

MSZ-EF18VE3(W)(B)(S)

MSZ-EF22VE3(W)(B)(S)

MSZ-EF25VE3(W)(B)(S)

MSZ-EF35VE3(W)(B)(S)

MSZ-EF42VE3(W)(B)(S)

MSZ-EF50VE3(W)(B)(S)

*4

*4

*4

*4

*4

*4

*1*6

*1*6

*1*6

*1*6

*1*6

*1*6

MSZ-HJ25VA

MSZ-HJ35VA

MSZ-DM25VA

MSZ-DM35VA

MSZ-HJ50VA

Series Type Model NameCapacity

15 18 20 22 25 35 42 50 60 71 100

M series Wall-Mounted

S series

2×2 Cassette

P series

4-way Cassette

Ceiling-Suspended

Ceiling-Concealed

Ceiling-Concealed

Floor-Standing

1-way Cassette

MSZ-GF•VE2

MFZ-KJ•VE2

MLZ-KA•VA

SLZ-KF•VA2

SEZ-KD•VAQ(L)

PLA-RP•EA

PCA-RP•KAQ

PEAD-RP•JA(L)Q

Branch Box Connection Compatibility Table

MSZ-SF•VE3

MSZ-SF•VA

MSZ-EF•VE3

MSZ-FH•VE2

Series Type Model NameCapacity

P15 P20 P25 P32 P40 P50 P63 P71 P80 P100 P140

CITYMULTIseries

1-way Cassette

2-way Cassette

4-way Cassette

2×2 Cassette

Ceiling Concealed

Ceiling Suspended

Wall Mounted

Floor StandingFloor Mounted Concealed

Air to Water unit

Lossnay

CITY MULTI Indoor Unit Compatibility Table

PMFY-P•VBM-E

PLFY-P•VLMD-E

PLFY-P•VEM-E

PLFY-P•VFM-E1

PEFY-P•VMS1(L)-E

PEFY-P•VMA(L)-E

PEFY-P•VMA3-E*1

PEFY-P•VMH-E

PEFY-P•VMR-E-L/R

PEFY-P•VMH-E-F

PCFY-P•VKM-E

PKFY-P•VBM-E

PKFY-P•VHM-E

PKFY-P•VKM-E

PFFY-P•VLEM-E

PFFY-P•VKM-E2

PFFY-P•VLRM-E

PFFY-P•VLRMM-E

PWFY-P•VM-E1/E2-AU*2

GUF-•RD(H)4*3

P125

Series I/U Type Model NameCapacity

15 18 20 22 25 35 42 50 60 71

M series Wall-Mounted

Floor-Standing MFZ-KJ•VE2

LEV Kit Connection Compatibility Table

MSZ-SF•VE3

MSZ-SF•VA

MSZ-EF•VE3

MSZ-FH•VE2

� MXZ Series � PUMY Series

108

Indoor Unit Compatibility Table

Indoor Unit

Outdoor Unit Inverter Models Heat pump type

MXZ-2D33VA

*3 *3 *3 *3 *3 *3 *3 *3 *3 *3MXZ-

2D42VA2MXZ-

2D53VA(H)2

*3 *3MXZ-

2E53VAHZMXZ-

3E54VAMXZ-

2DM40VAMXZ-

3DM50VAMXZ-

3E68VAMXZ-

4E83VA

*3MXZ-

4E83VAHZMXZ-

5E102VAMXZ-

4E72VAMXZ-

6D122VA

M series Wall-Mounted

S series 2×2Cassette

P series 4-wayCassette

Ceiling-Suspended

Ceiling-Concealed

Ceiling-Concealed

Floor-Standing

1-wayCassette

MSZ-FH25VE2

MSZ-FH35VE2

MSZ-FH50VE2

MSZ-SF15VA

MSZ-SF20VA

MSZ-SF25VE3

MSZ-SF35VE3

MSZ-SF42VE3

MSZ-SF50VE3

MSZ-GF60VE2

MSZ-GF71VE2

MFZ-KJ25VE2

MFZ-KJ35VE2

MFZ-KJ50VE2

MLZ-KA25VA

MLZ-KA35VA

MLZ-KA50VA

SLZ-KF25VA2

SLZ-KF35VA2

SLZ-KF50VA2

SEZ-KD25VAQ

SEZ-KD25VAL

SEZ-KD35VAQ

SEZ-KD35VAL

SEZ-KD50VAQ

SEZ-KD50VAL

SEZ-KD60VAQ

SEZ-KD60VAL

SEZ-KD71VAQ

SEZ-KD71VAL

PLA-RP50EA

PLA-RP60EA

PLA-RP71EA

PCA-RP50KAQ

PCA-RP60KAQ

PCA-RP71KAQ

PEAD-RP50JAQ

PEAD-RP50JALQ

PEAD-RP60JAQ

PEAD-RP60JALQ

PEAD-RP71JAQ

PEAD-RP71JALQ

Possible combinations of outdoor units and indoor units are shown below.

*1 Maximum total current of indoor units: 3A or less.*2 SEZ-KD25 cannot be connected with MXZ-2D(E)/3E/4E/5E when total capacity of connected indoor units is equivalent to outdoor capacity (capacity ratio is 1).*3 MXZ outdoor units are not designed to operate with a single indoor unit with one-to-one piping work. Please install at least two indoor units.*4 When connecting the MFZ-KJ Series indoor unit, additional refrigerant is required. For details, please refer to page 102. *5 Regarding MXZ-2D33, the second unit should be a different type in the case of selecting one MFZ-KJ.*6 P series cannot be connected with MXZ-4E83VAHZ when ampere limit adjustment function is operated.

*1 Authorized connectable indoor units are as follows; PUMY-P112:PEFY-P25×2+P32×2, PUMY-P125:PEFY-P32×4, PUMY-P140:PEFY-P32×3+P40×1, PUMY-P200YKM:PEFY-P40×2+P63×2*2 Note that connection is not allowed inside EU countries. PWFY can not connect to PUMY-P200YKM1.*3 Do not connect Lossnay remote controller(s). (PZ-61DR-E, PZ-60DR-E, PZ-52SF-E, PZ-43SMF-E)

*1*1*1*1*1*1

*2

*2

*1*1*1*1*1*1

*1*1*1

*1*1*1

*1*1*1

*1*1

*6

*6

*6

*6

*6

*1

*4*5 *4

*4

*4

*4

MSZ-LN35VG(W)(V)(R)(B)

MSZ-LN25VG(W)(V)(R)(B)

MSZ-EF18VE3(W)(B)(S)

MSZ-EF22VE3(W)(B)(S)

MSZ-EF25VE3(W)(B)(S)

MSZ-EF35VE3(W)(B)(S)

MSZ-EF42VE3(W)(B)(S)

MSZ-EF50VE3(W)(B)(S)

*4

*4

*4

*4

*4

*4

*1*6

*1*6

*1*6

*1*6

*1*6

*1*6

MSZ-HJ25VA

MSZ-HJ35VA

MSZ-DM25VA

MSZ-DM35VA

MSZ-HJ50VA

Series Type Model NameCapacity

15 18 20 22 25 35 42 50 60 71 100

M series Wall-Mounted

S series

2×2 Cassette

P series

4-way Cassette

Ceiling-Suspended

Ceiling-Concealed

Ceiling-Concealed

Floor-Standing

1-way Cassette

MSZ-GF•VE2

MFZ-KJ•VE2

MLZ-KA•VA

SLZ-KF•VA2

SEZ-KD•VAQ(L)

PLA-RP•EA

PCA-RP•KAQ

PEAD-RP•JA(L)Q

Branch Box Connection Compatibility Table

MSZ-SF•VE3

MSZ-SF•VA

MSZ-EF•VE3

MSZ-FH•VE2

Series Type Model NameCapacity

P15 P20 P25 P32 P40 P50 P63 P71 P80 P100 P140

CITYMULTIseries

1-way Cassette

2-way Cassette

4-way Cassette

2×2 Cassette

Ceiling Concealed

Ceiling Suspended

Wall Mounted

Floor StandingFloor Mounted Concealed

Air to Water unit

Lossnay

CITY MULTI Indoor Unit Compatibility Table

PMFY-P•VBM-E

PLFY-P•VLMD-E

PLFY-P•VEM-E

PLFY-P•VFM-E1

PEFY-P•VMS1(L)-E

PEFY-P•VMA(L)-E

PEFY-P•VMA3-E*1

PEFY-P•VMH-E

PEFY-P•VMR-E-L/R

PEFY-P•VMH-E-F

PCFY-P•VKM-E

PKFY-P•VBM-E

PKFY-P•VHM-E

PKFY-P•VKM-E

PFFY-P•VLEM-E

PFFY-P•VKM-E2

PFFY-P•VLRM-E

PFFY-P•VLRMM-E

PWFY-P•VM-E1/E2-AU*2

GUF-•RD(H)4*3

P125

Series I/U Type Model NameCapacity

15 18 20 22 25 35 42 50 60 71

M series Wall-Mounted

Floor-Standing MFZ-KJ•VE2

LEV Kit Connection Compatibility Table

MSZ-SF•VE3

MSZ-SF•VA

MSZ-EF•VE3

MSZ-FH•VE2

� MXZ Series � PUMY Series