Seismic Design of Buried Seismic Design of Buried StructuresStructures
Doug JenkinsDoug JenkinsInteractive Design ServicesInteractive Design Services
![Page 2: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/2.jpg)
Why Bother?Why Bother?
"Results show that the bending moments in the arch from horizontal earthquake loading can be significant in relation to the gravity load actions. These moments are also very sensitive to the backfill and surrounding soil stiffness properties and rather less sensitive to the foundation soils beneath the arch.”
John Wood
![Page 3: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/3.jpg)
Collapse of buried structure in JapanCollapse of buried structure in Japan
Spec
Possible earthquake related failure south of Sydney Consequences of failure
![Page 4: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/4.jpg)
Seismic design provisions in AS5100Seismic design provisions in AS5100
Specific rules are given for the categorisation of bridges. A formula is given for the fundamental period of bridge
structures (for use in category BEDC-1 designs only). Specific structural response factors are given for bridges of
different types. Structural detailing requirements relevant to bridges are
given.
![Page 5: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/5.jpg)
Problems with application to buried Problems with application to buried structuresstructures
The requirements for more detailed analysis methods are related to bridge span, and may not be relevant to buried structures.
Vertical earthquake effects may be important for buried structures, but only horizontal effects are required to be considered for almost all buried structures.
The formula for the fundamental period is not applicable to buried structures.
For static analysis the earthquake design force is not applicable to buried structures.
The appropriate response modification factor is not clear.
![Page 6: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/6.jpg)
Buried arch design studyBuried arch design study
Geraldton Southern Transport Corridor
14.5 m span x8 m high 3m and 15 m cover Acceleration 0.10g Site factor 1.5 Bridge Type II
![Page 7: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/7.jpg)
ClassificationClassification
Type III - Bridges and associated structures that are essential to post-earthquake recovery, as determined by the relevant authority.
Type II - Bridges that are designed to carry large volumes of traffic or bridges over other roadways, railways or buildings.
Type I - Bridges not of Type II or Type III.
![Page 8: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/8.jpg)
ClassificationClassification
Bridge classification Product of acceleration coefficient and site
factor Type III Type II Type I
aS ≥ 0.2
BEDC-4 BEDC-3 BEDC-2
0.1 ≤ aS < 0.2
BEDC-3 BEDC-2 BEDC-1
aS < 0.1
BEDC-2 BEDC-1 BEDC-1
![Page 9: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/9.jpg)
ClassificationClassification BEDC-1
– < 20 m span, no earthquake analysis
– > 20 m span, static analysis, horizontal forces
BEDC-2– Static or dynamic analysis
– > 35 m span, horizontal and vertical
BEDC-3– Static analysis only if a single dominant mode
– Consider horizontal and vertical loads
BEDC-4– Dynamic analysis; horizontal and vertical
![Page 10: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/10.jpg)
Buried arch design studyBuried arch design study
For each fill height (3m and 15 m):– Natural frequency analysis– Deflection under unit horizontal acceleration– Pseudo-static analysis– Response Spectrum analysis– Push-over analysis
![Page 11: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/11.jpg)
Buried arch design studyBuried arch design study For each of the analyses the following
material stiffness properties were used:
– Typical soil and uncracked concrete.
– Soil stiffness reduced by half and uncracked concrete.
– Soil stiffness reduced by half, and concrete moment-curvature relationship (static analyses), or cracked stiffness (response spectrum analyses)
A total of 26 separate analyses were carried out.
![Page 12: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/12.jpg)
Typical Finite Element MeshTypical Finite Element Mesh
![Page 13: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/13.jpg)
Mesh DetailMesh Detail
![Page 14: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/14.jpg)
3 metres cover Period, T 0.055 0.5 Stat T /Dyn T C
Elastic 0.605 119 0.600 99.1% 0.261 Reduced soil 0.850 231 0.836 98.4% 0.209 Reduced both 0.853 233 0.840 98.4% 0.208
15 metres cover Elastic 0.999 341 1.016 101.7% 0.188 Reduced soil 1.405 679 1.433 102.0% 0.149 Reduced both 1.408 680 1.434 101.8% 0.149
Fundamental period, Static Fundamental period, Static Design Force CoefficientDesign Force Coefficient
![Page 15: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/15.jpg)
Static analysis, 3m CoverStatic analysis, 3m Cover
-200
-150
-100
-50
0
50
100
150
200
0.0 5.0 10.0 15.0 20.0 25.0
Distance around arch, m
Ben
din
g M
om
ent,
kN
m
Standard stiffness Reduced soil stiffness Reduced soil and beam stiff
![Page 16: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/16.jpg)
Dynamic Analysis, 3m CoverDynamic Analysis, 3m Cover
-250
-200
-150
-100
-50
0
50
100
150
200
250
0.0 5.0 10.0 15.0 20.0 25.0
Distance around arch, m
Ben
din
g M
om
ent,
kN
m
Dynamic Lin Dyn, reduced soil stiffness Dyn, reduced soil&beam stiff
![Page 17: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/17.jpg)
Maximum Moments, 3m CoverMaximum Moments, 3m Cover
-250
-200
-150
-100
-50
0
50
100
150
200
250
Standard Stiffness Reduced Soil Stiffness Reduced Soil and Beam
Ben
din
g M
om
ent,
kN
m
Pseudo-Static, +ve Resp. Spect. +ve Pseudo-Static, -ve Resp. Spect. -ve
![Page 18: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/18.jpg)
Static analysis, 15m CoverStatic analysis, 15m Cover
-250
-200
-150
-100
-50
0
50
100
150
200
0.0 5.0 10.0 15.0 20.0 25.0
Distance around arch, m
Ben
din
g M
om
ent,
kN
m
Standard Reduced soil stiffness Reduced soil and beam stiff
![Page 19: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/19.jpg)
Dynamic Analysis, 15m CoverDynamic Analysis, 15m Cover
-250
-200
-150
-100
-50
0
50
100
150
200
250
0.0 5.0 10.0 15.0 20.0 25.0
Distance around arch, m
Be
nd
ing
Mo
me
nt,
kN
m
Dynamic Lin Dyn, reduced soil stiffness Dyn, reduced soil&beam stiff
![Page 20: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/20.jpg)
Maximum Moments, 15m CoverMaximum Moments, 15m Cover
-250
-200
-150
-100
-50
0
50
100
150
200
250
Standard Stiffness Reduced Soil Stiffness Reduced Soil and Beam
Ben
din
g M
om
ent,
kN
m
Pseudo-Static, +ve Resp. Spect. +ve Pseudo-Static, -ve Resp. Spect. -ve
![Page 21: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/21.jpg)
Axial Load - Seismic Increment Axial Load - Seismic Increment or reduction, 15m Coveror reduction, 15m Cover
15m Cover Axial Loads, Seismic Increment
0
200
400
600
800
1000
1200
0.0 5.0 10.0 15.0 20.0 25.0
Distance around arch, m
Axi
al F
orc
e, k
N
Pseudo Static Response Spectrum
![Page 22: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/22.jpg)
AnimationsAnimations
First mode shape - 3m and 15 m cover, horizontal and vertical– Arch + Fill– Fill only
![Page 23: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/23.jpg)
Moment-CurvatureMoment-Curvature
![Page 24: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/24.jpg)
Push-over analysis, 15m CoverPush-over analysis, 15m Cover
-800
-600
-400
-200
0
200
400
600
800
0.0 20.0 40.0 60.0 80.0 100.0 120.0 140.0 160.0 180.0 200.0
Crown X Displacement, mm
Ben
din
g M
om
ent,
kN
m
Min Moment Max Moment
![Page 25: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/25.jpg)
AnimationsAnimations
Push-over analysis– 15 m fill– 3 m fill
![Page 26: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/26.jpg)
ConclusionsConclusions
Buried arch structures with low to moderate axial loads have a large reserve ductility.
Where the failure mode is concrete compression failure under moderate earthquake loading is a possibility.
Bending moments found in the dynamic analyses were up to 50% higher than the static analysis results.
![Page 27: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/27.jpg)
RecommendationsRecommendations Structure classification be related to fill height, rather than
span. Response modification factor to be related to the capacity
reduction factor. BEDC-1 and BEDC-2: design for vertical and horizontal
earthquake loads, using static or dynamic analysis. BEDC-3 and BEDC-4: design for vertical and horizontal
earthquake loads, using dynamic analysis. Determine the fundamental period from computer analysis
or formula for BEDC-1 and 2 structures.
– T = 0.055 0.5 seconds = deflection in millimetres at ground surface above the arch
under 1g horizontal load.
![Page 28: Seismic Design of Buried Structures](https://reader035.vdocuments.us/reader035/viewer/2022081513/568150da550346895dbefce2/html5/thumbnails/28.jpg)
Further InformationFurther Information
www.interactiveds.com.au