TANKLESS ELECTRIC WATER HEATERS
Quick GuideSH Models for Radiant Floor HeatingCompliance & Listings: ANSI/UL 834, CSA, NSF, HUD, NEC
SEISCOSpaceHeater
RADIANT MANIFOLD
BKR
BKR
CIRCULATINGPUMP
ROOMTHERMOSTAT
EXPANSION TANK
SHUT OFF VALVES
CheckValve
AirSeparator(Bleeder)
240 V Power
120 V Power
Double-Pole Breakers
In-FloorTubing
ReturnWater
Hot Water
Return Water
*Warranted for Space Heating
Applications only. Not to be used for
WaterHeating.
This new micro-boiler is the ideal replacement
for traditional boilers and tank-type heaters and is the enabling technology for use
with active renewable energy systems such as solar and
geothermal systems.
Features
• ANSI/UL 834 Approval Listing for Space Heating Systems• Works with tubing and manifold systems• No minimum � ow activation required• Built-in DSM Utility Integration option• Compatible with Home Energy Management Systems• Heats � uid mixtures including ethylene glycol (antifreeze)• No moving parts• Very small & compact• Light weight modular construction• No restriction to � ow
• Standard 3/4 inch plumbing connections• Microprocessor digital control• Power sharing & variable power control technology• Continuous venting• Heats continuously only when needed, no storage• Self-diagnostics• Redundant safety devices• High performance polymer nylon chamber material• Built-in Leak detector and alarm• Rust & corrosion resistant
SEISCO FLOW RATES, TEMPERATURE RISE & HEAT RATINGSSeiscoModel
Heat OutputRating(BTU)
Max. GPM forTemp. Rise of
10°F
Max. GPM forTemp. Rise of
20°F
Max. GPM forTemp. Rise of
48°F
Max. GPM forTemp. Rise of
64°F
Max. GPM forTemp. Rise of
76°FSH-09 30,710 6.1 3.1 1.3 1.0 0.8SH-11 37,540 7.5 3.8 1.6 1.2 1.0SH-14 47,780 9.6 4.8 2.0 1.5 1.3SH-18 61,430 12.3 6.1 2.6 2.0 1.6SH-22 75,080 15.0 7.5 3.1 2.3 2.0SH-28 95,560 19.1 9.6 4.0 3.0 2.5
GPM = Gallons per minute (Flow Rate) SPACE HEATING & Active Renewable Energy Back-up SYSTEM Requirements
HEATING SYSTEM SuggestedSeisco Model(s)
Seisco Temp Setting
Radiant Floor All Models* 100-120 FHydro-Heat SH-28+ 125-135 F
Baseboard Heat SH-28* 130-140 FDual Heating SH-28+ 120 F
Solar Backup Heat SH-28, 22 120-135 FGeothermal Backup SH-28, 22 120-135 F
* The “Heat Loss Rate” (BTU/Hr.) should be calculated by a qualified heating contractor. Select a Seisco ModelBTU Rating using 125% of the calculated Heat Loss Rate for the area that is being heated.SEISCO MODEL SPECIFICATIONS
SeiscoModel
Weight(LBS)
Height(INCHES)
Width(INCHES)
Depth(INCHES)
PlumbingFittings
(INCHES)
HeatingElements
(WATTS X NO.)Energy Factor
SH-09 15 15 ¾ 10 ¼ 6 ¼ ¾ 4500 X 2 0.99+
SH-11 15 15 ¾ 10 ¼ 6 ¼ ¾ 5500 X 2 0.99+
SH-14 15 15 ¾ 10 ¼ 6 ¼ ¾ 7000 X 2 0.99+
SH-18 23 15 ¾ 15 ¾ 6 ¼ ¾ 4500 X 4 0.99+
SH-22 23 15 ¾ 15 ¾ 6 ¼ ¾ 5500 X 4 0.99+
SH-28 23 15 ¾ 15 ¾ 6 ¼ ¾ 7000 X 4 0.99+
SEISCO ELECTRICAL RATINGSSeiscoModel
MaximumPower Rating
(kW)
VoltageRating(VAC)
MaximumCurrent Rating
(AMPS)
Number ofCircuits Required
(Two Wire)
Number of Circuit Breakers Required
(Double Pole)
CircuitBreaker Size
(AMPS)SH-09 9 240 37.5 1 1 50SH-11 11 240 46 1 1 60SH-14 14 240 58 2* 2* 40SH-18 18 240 75 2 2 50SH-22 22 240 91 2 2 60SH-28 28 240 116 4** 4** 40
* Optional one (1), 75 AMP circuit supply – Check with manufacturer for jumpers that must be installed on control board for this option.
Typical Heat Loss Rates for New Homes
Sq. Ft. BTU Loss Seisco Selection3,000+ 80,000 to 125,000 (Use 2 SH-18’s or 2 SH-22s)**2,500+ 50,000 to 80,000 (Use 1 SH-28 or 1 SH-22)1,500+ 35,000 to 50,000 (Use 1 SH-18 or 1 SH-22) 800+ 20,000 to 35,000 (Use 1 SH-14 or 1 SH-18)** Plumbed in Parallel
Models
SH-28SH-22SH-18
Models
SH-14SH-11SH-09