Think New: Securing and Greening Your IT at The Same Time
May 2010
Chris Andrew | VP Security Technologies
Agenda
Why Go Green?
Solution Overview» Wake-On-LAN (WOL)
» Power Policy Wizard
» Power Management Reports
Q & A
2
Why Go Green?
Environmental Impact
The global IT and communications industry accounts for approximately 2% of all global CO2 emissions1
There are currently over 1 billion PCs, projected to be 2.25 billion by 20152
4
Sources: 1.Gartner, May 2007 2.Forrester Research
Financial Impact
Energy costs –typically around 10% of an IT budget—could account for 50% of the average IT budget in just a few years1
“By 2010, about half of the Forbes Global 2000 companies will spend more on energy than on hardware”2
5
Sources: 1.Mark, Roy, House Green Lights EPA Data Centers Study, Internetnews.com (July 13, 2006) 2.Businessweek.com: CEO Guide To Green Computing. From Gartner
6
Industry Averages
» The average desktop PC wastes nearly half the power it consumes
» Servers lose approximately one-third of their power as heat
» 90% of desktops don’t use power management settings
7
Save a Buck, Save the Planet!
PC Energy Savings make fiscal sense» Power savings alone
Energy rebate programs are available» Up to $3 per PC depending on where
you live
Save money, reduce emissions…» This is NOT a “carbon offset”
8
Best Practices
Implement Power Management software» Hibernate desktops after hours
» Require a monitor-off policy
» Studies show 250 to 300kWh/ year per PC
Replace old desktops & monitors with EnergyStar rated models» Could save 140kWh/ year per PC
Virtualize servers» Reduce server count
» Reduce cooling requirements
9
Downsides to Power Management
End User complaints» Computer takes too long to boot
» Lost my work because you shutdown my PC!
Sleeping computers cannot be managed» Software can’t be deployed
» Policies updates cannot be applied
» Remote desktop unavailable
Can also make the network less secure» Computers that are turned off can’t be scanned
» Patches cannot be installed to a computer that is hibernating
» AV Updates can be delayed
» Security Policies cannot be implemented until all nodes connect
10
The Green IT Mandate
1. Save CO2 Emissions
2. Save Money
3. Save Waste
… without sacrificing security
… without loosing manageability
… without alienating your user base !
Solution Overview
12
Solution Areas
Wake-On-LAN» Securing / Managing your systems
Power Policy Wizard» Defining and distributing power policies for your systems
Power Management Reports» Qualifying for a power company rebate
New feature included with L.E.M.S.S. 7.0 SP1:
Wake-On-LAN
Wake-On-LAN Overview
Allow maintenance of systems that are powered down
» Patch Deployment
» Policy Updates
» Software Distribution
Perform system maintenance during off hours» No interruption to end users
Requested feature from customers» Many of our enterprise scale customers have
asked for this feature
14
15
Use of Enterprise Service Bus Platform
First add on plug-in for the L.E.M.S.S. platform» Installs on top of L.E.M.S.S. 7.0 SP1
» Wakeup requests are PUSHED to the Wakepoint
» Wakepoint posts back its status and subnet ranges
EDS Module (Server Plug in)» Server threads that read and write the Endpoint Wake Times data
» Sends out the wake requests every 5 minutes
EPS Module (aka “Wakepoint”)» Client side module that processes the wakeup requests
» One Wakepoint per network segment; when we ship…
21
Waking Machines by Hours Of Operation
Use your existing agent Hours Of Operation policy» Agent can communicate and download patches
» Ideal time to wake up is at the beginning of HOP period
» Multiple HOP times can be defined each day
25
Waking Machines Using Daily Wake Times
• Use when Hours Of Operation are not established
• Same wake time for every computer within a group
Power Policy WizardRequires Lumension® Content Wizard
Power Policy Overview
Establish corporate wide policy» Hibernation settings
» Turn Off Monitor settings
» Turn Off HDD settings
Reach all endpoints» Deploy with GPO
» Non-domain computers
» Laptops
Enforce compliance over time» Verify that the policy stays applied
34
Add-On module for L.E.M.S.S. 7.0 SP1
Power Management Reports
Power Management Reports
Power Savings Calculator» “What if” calculations on power usage
» Model some power savings scenarios
Gather information required for a rebate» PCs under management
» Licenses installed
» Power Savings
Power Monitoring» Measure actual endpoint uptime
» Monitor states (on/ monitor-off/ sleep,..)
Dashboard
41
42
Qualifying for a Rebate
Step One: Identify a plan» E.g. Aim to have Desktop and Laptop PCs idle or sleeping for 16+ hours per
day, instead of running 24 x 7 x 365
Step Two: Apply to your Power Company» Calculate your savings
» Submit formal or informal plan
» Varies by power company
Step Three: Implement your plan » Purchase Power Management software, etc
Step Four: Document your results» Receive your rebate
43
44
Estimate Your Power Savings
• Check local Power Company requirements» Is there a form to fill out?
» Is a formal plan required?
» Are laptop computers eligible?
» Etc…
• Calculate your power savings estimates» By machine type» By power savings strategy
• Submit your application for a rebate
45
46
47
Power Management Dashboard
48
Uptime Report
• Deploy new power management settings» Active Directory / Domain Policy
» Local Power Policy using Power Wizard
• Monitor uptime over time» Uptime should decrease rapidly» Find the groups /etc that are out of compliance
49
50
51
Energy Usage Report
• Measures estimated energy consumption» Factors in uptime and machine type» Quickly locate the groups that will save the most money
52
53
Demos are available in the Resource Center –
http://www.lumension.com/Products/Endpoint-Management-Security-Suite/Endpoint-Power-Management.aspx