G1 SECTION G WIRING DIAGRAMS The wiring diagram guide lists compressors by model designa- tion. These are indexed against an Electrical Characteristics code. (The third group of numbers in the model number.) The third letter of third group of the model number may be missing. It may be any one of a number of letters representing electrical characteristics. These diagrams represent typical wiring connections for the compressors listed but may not be identical to the diagram in the compressor terminal box. Discontinued wiring diagrams listed in the back of this section are for compressors that are no longer available by Emerson Climate Technologies, Inc. The replacement wiring diagram is not necessary the same as the old wiring diagram show in the front of this section. Use caution when selecting the appropriate wiring diagram. This section contains current information on Copeland ® brand products. Information on obsolete models can be obtained from your local Emerson Climate Technologies wholesaler.

Upload: others

Post on 16-Mar-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

G1

SECTION G

WIRING DIAGRAMS

The wiring diagram guide lists compressors by model designa-tion. These are indexed against an Electrical Characteristics code. (The third group of numbers in the model number.) The third letter of third group of the model number may be missing. It may be any one of a number of letters representing electrical characteristics.

These diagrams represent typical wiring connections for the compressors listed but may not be identical to the diagram in the compressor terminal box.

Discontinued wiring diagrams listed in the back of this section are for compressors that are no longer available by Emerson Climate Technologies, Inc. The replacement wiring diagram is not necessary the same as the old wiring diagram show in the front of this section. Use caution when selecting the appropriate wiring diagram.

This section contains current information on Copeland® brand products. Information on obsolete models can be obtained from your local Emerson Climate Technologies wholesaler.

G2

WELDED COMPRESSORS DIAGRAMS

MODEL TF* ES8 TS* (2) PF* CSVCR,CS,CP

(5) 0770 (1,5,7) 005-1211-01

(1,5) 005-1211 (5) 0782(1,3,7) 005-1210 (1,3,7) 005-1212

CT 1319 1318

R 0833 0778/0779

0865(1) 005-0670 0768

MODEL IA* SAA CA* (2) PA* CF* TF*R 0831/0832

0776/077707800769

07670818/0819 0820

0774/077508340781

A-LINE 09291223 0930 0932 0932 0931 0980

(1) DIAGRAM MOLDED IN COMPRESSOR TERMINAL BOX. (2) MAY REQUIRE PTC THERMISTOR (3) 59 FRAME(4) 70 FRAME(5) 63 FRAME(6) 4 PIN SENSOR CONNECTION(7) FOR PROPER WIRING SEE SYSTEM WIRING DIAGRAM

NOTE: ASTERISK AFTER FIRST TWO LETTERS INDICATES MAY BE ANY LETTER DEPENDING ON ELECTRICAL CHARACTERISTICS.

G3

SCROLL DIAGRAMSMODEL TF* (2) PF* TW*

ZB30-45K, ZF13-18K, ZS30-45K, ZMD18K, ZBD30-45K, ZBH30-45K(REFR)ZR46-81K, ZRD49-72K,ZP54-57K(AC)

(3) 0880 (1,3) 005-1213

ZF6-11K, ZS15-26K, ZB15-26K, ZBH21K(REFR)ZR28-48K, ZP32-44K(AC)

(1,4,5)005-1270

(1,4,5)005-1270

ZB50-88K (REFR)ZR84-144K (AC) (1) 005-1271

ZC40,60CCRYO (3) 0880 (1,3)

005-1213

ZR90K, ZR11-19MZP180K (AC) 1201

ZF24-48K, ZB,ZS56-92K,ZB,ZS11M (REFR) 0906

ZB10-14K, ZBH11-14K(REFR)ZR16-24K, ZP16-23K(AC)

(1,4,5)005-1270 (1,4,5) 005-1270

ZP235- ZP295K, ZR250,300K, ZR310,380KLarge Commercial Scroll (LCS)

0953

ZR22 - ZR 61, ZF09 - 11, ZX21, ZS21-26, VR61 1199

(1) DIAGRAM MOLDED IN COMPRESSOR TERMINAL BOX. (2) MAY REQUIRE PTC THERMISTOR (3) 70 FRAME(4) 63 FRAME(5) FOR PROPER WIRING SEE SYSTEM WIRING DIAGRAM

NOTE: ASTERISK AFTER FIRST TWO LETTERS INDICATES MAY BE ANY LETTER DEPENDING ON ELECTRICAL CHARACTERISTICS.

G4

COPELAMETIC DIAGRAMS MODEL TF* ES* ESM TS*

M 0803 (6) 0900

N 0803

2D 0803 (5,6) 0897

3D0803, 0816(4) 0840 0837

(5,6) 0897

4 (5,6) 0897 (6) 0900 (6) 2169(7) 1851

6 (5,6) 0897 (6) 0900 (6) 2169

8 (6) 2169

9 08030837 (5,6) 0897 (6) 0900

MODEL XAA IA* SAA CAF/CAGH 0809 0809 0809 (3) 0822

K 0809 0809 (3) 0822

(1) SIX LEAD MOTOR(2) THREE LEAD MOTOR (3) 50 HERTZ APPLICATIONS(4) VDE GROUNDING (5) SMALLER VERSION OF 0899(6) DUAL VOLTAGE MODULE(7) 24 VOLT MODULE NOTE: ASTERISK AFTER FIRST TWO LETTERS INDICATES MAY

BE ANY LETTER DEPENDING ON ELECTRICAL CHARACTERISTICS.

G5

COPELAMETIC DIAGRAMS

MODEL CA* CFB(1) FS* (1) TSE (1) TSU

TA*(2)TSE (2) TS7 (2)TSU (2) TSC

E 0807 0821 0806

H 0807 0810

K 0807 0810

L 0802 0805

M 0804 (6) 2170(5,6) 0914

N 0804

2D 0804 (6) 2170

3 0807 0806

3D (6) 2170

4(6) 2170 (6) 0902 (7)1852

(6) 2167

6 (6) 2170(6) 0902 (6) 2167

8 (6) 2170 (6) 2167

9 0804 (6) 2170 (6) 2167

(1) SIX LEAD MOTOR(2) THREE LEAD MOTOR (3) 50 HERTZ APPLICATIONS(4) VDE GROUNDING (5) SMALLER VERSION OF 0899 (6) DUAL VOLTAGE MODULE(7) 24 VOLT MODULE

NOTE: ASTERISK AFTER FIRST TWO LETTERS INDICATES MAY BE ANY LETTER DEPENDING ON ELECTRICAL CHARACTERISTICS.

G6

The following tables lists discontinued wiring diagrams and their replacements.

MODEL VOLTAGE OLDDIAGRAM

NEWDIAGRAM

JR IFA 0784 No Replacement

J,XH IA* 005-0655005-0697 No Replacement

J,XH SAA 0813 No Replacement

J,XH CA* 0820 No Replacement

J,XH PA* 0781 No Replacement

BR/QR ES* 0758 0875

BR/QR TS* 0716 0875

BR/QR EW8 0825 0875 (ES8)

BR/QR TS* 0874 0948

BR/QR ES8 0875 0949

BR/QR TF* 005-0492 005-0922

BR/QR TF* 005-0637 005-0922

BR/QR ES* 0815 0875

BR/QR TF* 005-0922 005-1043

BR/QR TF* 005-1043 No Replacement

BR/QR ES8 0883 No Replacement

BR/QR TS* 0882 No Replacement

BR/QR TS* 0948 No Replacement

CR ES* 0757 0875

CR EW8 0825 0875

CR ES* 0876 0875

CR EW8 0823 No Replacement

CR ES* 0811 0875

G7

MODEL VOLTAGE OLDDIAGRAM

NEWDIAGRAM

CR EW8 0824 0875

CR, CS ES* 0801 No Replacement

CT CSV 0751 0884

CT TS* 0752 0885

CR 63FR PF* 005-0678 005-0799

CR PF* 005-0679 005-0799

CV TF* 0770 No Replacement

CR ES8 0875 0917

CT CSV 0884 0918

CT TS* 0885 0919

CR ES8 0917 0949

CT TS* 0919 1319

CT CSV 0918 1318

ZF,ZS,ZB,ZR,ZP,ZB TF* 0826 0880

ASPEN PF* 005-0838 No Replacement

ASPEN TF* 1196 No Replacement

ASPEN PF* 005-0706 No Replacement

ZF,ZS,ZB PF* 005-0788 005-0837

ZF,ZS,ZB PF* 005-0777 005-0819

ZF,ZS,ZB PF* 005-0819 005-0840

ASPEN PF* 0756 No Replacement

ZB PF* 005-0788 005-0837

ZB PF* 005-0837 005-0860

ZB,ZF PF* 005-0777 005-0819

ZB,ZF,ZS PF* 005-0819 005-0840

ZR (AC) TW* 1825 1201

G8

MODEL VOLTAGE OLD DIAGRAM

NEWDIAGRAM

ZF,ZS,ZB(REFR) TW* 1825 0906

ZB PF* 005-0840 005-1062

ZB,ZR TF* 005-0868 005-0922

ZB,ZR TF* 005-0922 005-1043

ZB, ZS, ZF, ZRD, ZP

PF* 005-0860 005-1071

9 THC,TLC 0748 0853 (TSC)

9 THC,TLC 0748 0803 (TFC)

9 THD,TLD 0748 0803 (TFD)

9 THE,TLE 0748 0803 (TFE)

9 FS* 0856 0899, See note 2

9 ESM 0858 0900, See note 2

9 TS* 0853 0896, See note 2

9 TSE,TSU,TSC,TS7 0896 2167

9 FS*,TSE,TSU 0899 2170

4/6 TSE 0759 No Replacement

4/6 FS*,TSE, TSU 0841 0857

4/6 TSE,TSU, TS7 0760 0853, See note 1

4/6 ES* 0762 0854, See note 1

4/6 ESM 0848 0858, See note 1

4/6,8 TS* 0763 0855, See note 1

4/6,8 FS* 0765 0856, See note 1

G9

MODEL VOLTAGE OLD DIAGRAM

NEWDIAGRAM

4/6,8 TS* 0898 2169

4/6,8 TSE,TSU,TSC,TS7 0896 2167

4/6,8 FS*,TSE,TSU 0899 2170

4/6 TSE/TSU 0765 0856, See note 1

4DK6, 4DS6 FSD 0902 1299, See note 2

4DK6, 4DS6 FSD 1299 2177, See note 2

4,6 FS* 0857 0902, See note 2

4,6 TSE 0853 0896, See note 2

4,6 TS* 0855 0898,See note 2

4,6 ESM 0858 0900, See note 2

8 TS* 0855 0898, See note 2

8 TS7 0853 0896, See note 2

M FSC 0849 0859, See Note 1

M FS* 0856 0899, See note 2

M FS* 0859 0914, See note 2

M ES* 0854 0897, See note 2

2D FS* 0856 0899, See note 2

2D ES* 0854 0897, See note 2

3D ES* 0854 0897, See note 2

Notes:1. Models replaced with dual voltage 31aa module. (Requires a jumper wire from L2 to LO for 120V and L2 to HI for

240V)2. Models replaced with dual voltage 41aa module. (Jumper wire not required)

G10

Wiring Diagram 005-0670

G11

Wiring Diagram 0767

G12

Wiring Diagram 0768

G13

Wiring Diagram 0769

G14

Wiring Diagram 0770

G15

Wiring Diagram 0774/0775

G16

Wiring Diagram 005-0776, 005-0821

G17

Wiring Diagram 0776/0777

G18

Wiring Diagram 0778/0779

G19

Wiring Diagram 0780

G20

Wiring Diagram 0781

G21

Wiring Diagram 0782

G22

Wiring Diagram 0802

G23

Wiring Diagram 0803

G24

Wiring Diagram 0804

G25

Wiring Diagram 0805

G26

Wiring Diagram 0806

G27

Wiring Diagram 0807

G28

Wiring Diagram 0809

G29

Wiring Diagram 0810

G30

Wiring Diagram 0816

G31

Wiring Diagram 0818/0819

G32

Wiring Diagram 0820

G33

Wiring Diagram 0821

G34

Wiring Diagram 0822

CRANKCASE HEATER, WHEN APPLIED, MUST BE CONNECTEDONLY TO ITS RATED VOLTAGE.

USE COPPER CONDUCTORS ONLY.

USE MINIMUM 75 C WIRE FOR AMPACITY DETERMINATION.USE THIS EQUIPMENT ON A GROUNDED SYSTEM ONLY.

9-93 052-0822-00

EXTERNAL MOTOR PROTECTION-ALLOW TIME FOR RESET.

RS

C

MOTOR WINDINGCONNECTIONS

LINE

21

R C S

125

CURRENTRELAY

STARTCAPACITOR

BLACK

RUN CAPACITORYELLOW

RED

BLUE

ON 115 VOLT, CONNECT NEUTRAL TO TERMINAL "1".OVERCURRENT PROTECTION DEVICE RATING AND TYPE MUST BEIN ACCORDANCE WITH REGULATORY AGENCY END PRODUCTAPPROVALS-SEE SYSTEM NAMEPLATE.

G35

Wiring Diagram 0831/0832

G36

Wiring Diagram 0833

G37

Wiring Diagram 0834

G38

Wiring Diagram 0837

G39

Wiring Diagram 0840

G40

Wiring Diagram 0865

G41

Wiring Diagram 0880

G42

Wiring Diagram 0897 (Top)

G43

Wiring Diagram 0897 (Bottom)

G44

Wiring Diagram 0900 (Top)

G45

Wiring Diagram 0900 (Bottom)

G46

Wiring Diagram 0906

TO MOTOR TERMINAL BLOCK/VERS BORNES DE BRANCHMENT DES BOUNES MOTEUR/ZUR BELEGUNGDER MOTOR KLEMMEN

NOTIZ:MOTORSCHUTZGERAET HAT EINEZEITVERZOEGERUNG VON 30 MINUTEN ZUMRUECKSCHALTEN

NOTE:EN CAS DE DECLENCHEMENT DU MODULEDE PROTECTION, LE REARMEMENT EST RETARDEA 30 MINUTES.

PROTECTOR MODULE AND OPTIONAL CRANKCASE HEATER MUSTBE CONNECTED ONLY TO THEIR RATED VOLTAGE.

USE COPPER CONDUCTORS ONLY.USE A TEMPERATURE OF 75C WHEN DETERMININGCROSS SECTION OF LEAD FOR MAX CURRENT.USE THIS EQUIPMENT ON A GROUNDED SYSTEM ONLY.PRIMARY SINGLE PHASE FAILURE PROTECTION IS PROVIDED.

LE MODULE DU DISPOSITIF DE PROTECTION ET LE CHAUFFE-CARTERFACULTATIF DOIVENT ETRE BRANCHES A LA TENSION NOMINALEAPPROPRIEE.

N'UTILISER QUE DES CONDUCTEURS EN CUIVRE.UTILIER UNE TEMPERATURE ED 75C POUR DETERMINERLA SECTION DES CABLES POUR LE COURANT MAXIMUM.EMPLOYER CET EQUIPEMENT SEULEMENT SUR SYSTEME MIS A LA TERRE.PROTECTION PRIMAIRE MONOPHASEE FOURNIE.

LE TYPE ET LES CARACTERISTIQUES NOMINALES DU DISPOSITIF DEPROTECTION CONTRE LES SURINTENSITES DOIVENT ETRE CONFORMES AUXEXIGENCES DES POUVOIRS DE REGLEMENTATION VISANT LE PRODUIT FINI-VOIR LA PLAQUE SIGNALETIQUE.

SCHUTZGERAET UND KURBELGEHAEUSEHEIZER (FALLS VORHANDEN)DUERFEN NUR MIT NENNSPANNUNG BETRIEBEN WERDEN.

NUR KUPFERLEITUNGEN VERWENDEN.

SCHUTZ BEI PHASENAUSFALL AUF DER PRIMAERSEITE IST GEWAEHRLEISTET.ANLAGE NUR MIT ERDUNG VERWENDEN.

ZUR BESTIMMUNG DES LEITERQUERSCHNITTS MUESSEN KABEL VERWENDET WERDEN,DIE FUER EINE BELASTUNG VON HUECHSTENS 75C ZUGELASSEN SIND.

NENNLEISTUNG UND TYP DES UEBERSTROMSCHUTZSCHALTERS MUESSENIN UEBEREINSTIMMUNG MIT ZUTREFFENDEN VORSCHRIFTEN SEIN-BITTE TYPENSCHILD BEACHTEN.

NOTE:SOLID STATE MODULE HAS 30 MINUTESTIME DELAY BEFORE RESET IN EVENTOF PROTECTOR TRIP.

INTERNAL THERMALSENSORS/CAPTEURS THERMIQUESINTERNES/INTERNETEMPERATURSENSOREN

TO CONTROL CIRCUIT/VERS LE CIRCUIT DECOMMANDE/ZUM STEUERSTROMKREIS

PROTECTOR MODULE VOLTAGE/TENSION DU MODULE DU DISPOSITIFDE PROTECTION/ANSCHLUSSPANNUNG DES SCHUTZGERAETES1

2 OVERCURRENT PROTECTION DEVICE RATING AND TYPE MUSTBE IN ACCORDANCE WITH REGULATION AND PRODUCT APPROVALS-SEE SYSTEM NAMEPLATE.

052-0906-00 (8525681)

F0R KRIWAN SCY (PHASE SENSING) MODULES ONLY3

3

L1

MOTOR WINDINGCONNECTIONS/BORNES DESENROULEMENTS DUMOTEUR/ANSCHLUSSDER MOTORWICKLUNGEN

L2

L3

L1 L2L3

FOR USE WITHKRIWAN SCY(PHASE SENSING)MODULE ONLY

6/99

21

S2 S1 M2 M1T2 T1

3

L3L1 L2

FOR USE WITH KRIWANSCY (PHASE SENSING)MODULE ONLY

G47

This page is left blank intentionally.

G48

Wiring Diagram 0914 (Top)

G49

Wiring Diagram 0914 (Bottom)

G50

Wiring Diagram 0929

USE MINIMUM 75C COPPER

WIRE FOR AMPACITY

DETERMINATION. WHEN PROVIDED,

CRANKCASE HEATER AND FAN

MUST BE CONNECTED ONLY TO

THEIR RATED VOLTAGE.

SYSTEM OVERCURRENT

PROTECTION DEVICE RATING

AND TYPE MUST BE IN

ACCORDANCE WITH REGULATORY

AGENCY END PRODUCT

BLK

CURRENT

RELAY

R

EXTERNAL

PROTECTOR C

1

LINE GND

APPROVALS - SEE SYSTEM

NAMEPLATE. FAN LEADS

ARE FACTORY PROVIDED

ON CONDENSING UNITS.

S

LINE (230V)

8-02 052-0929-00

2

START CAPACITORLINE

NEUTRAL (115V)

FAN

G51

Wiring Diagram 0930

G52

Wiring Diagram 0931

RED

BLU

INTERNAL PROTECTOR

LINE GND

BLK

RUN CAPACITOR

(WHEN PROVIDED)

POTENTIAL RELAY

(WHEN PROVIDED)

C

SR

5

21

YEL

USE MINIMUM 75C

COPPER WIRE FOR

AMPACITY

DETERMINATION.

WHEN PROVIDED,

CRANKCASE HEATER

AND FAN MUST BE

CONNECTED ONLY TO

THEIR RATED VOLTAGE.

LINE

(230V)

-SEE SYSTEM NAMEPLATE.

11-02 052-0931-00

NEUTRAL

(115V)

START

CAPACITOR

(WHEN PROVIDED)

LINE

FAN

SYSTEM OVERCURRENT PROTECTION

DEVICE RATING AND TYPE MUST

BE IN ACCORDANCE WITH REGULATORY

AGENCY END PRODUCT APPROVALS

G53

Wiring Diagram 0932

RED

BLU

EXTERNAL

PROTECTOR

LINE GND

BLK RUN CAPACITOR

(WHEN PROVIDED)

POTENTIAL RELAY

(WHEN PROVIDED)

C

SR

5

21

YEL

USE MINIMUM 75C COPPER

WIRE FOR AMPACITY

DETERMINATION.

WHEN PROVIDED, CRANKCASE

HEATER AND FAN MUST BE

CONNECTED ONLY

TO THEIR RATED

VOLTAGE.

SYSTEM OVERCURRENT

PROTECTION DEVICE RATING

AND TYPE MUST BE IN

ACCORDANCE WITH REGULATORY

AGENCY END

LINE

(230V)

PRODUCT APPROVALS

-SEE SYSTEM NAMEPLATE.

11-02 052-0932-00

NEUTRAL

(115V)

LINE

FAN

START CAPACITOR

(WHEN PROVIDED)

G54

Wiring Diagram 0953

G55

Wiring Diagram 0980

G56

Wiring Diagram 1199

G57

Wiring Diagram 1201

NOTIZ:MOTORSCHUTZGER-T HAT EINE ZEITVERZ+GERUNGVON 30 MINUTEN ZUM R_CKSCHALTEN

NOTE:EN CAS DE DECLENCHEMENT DU MODULEDE PROTECTION, LE REARMEMENT EST RETARDEDE 30 MINUTES.

PROTECTOR MODULE AND OPTIONAL CRANKCASE HEATER MUSTBE CONNECTED ONLY TO THEIR RATED VOLTAGE.

USE THIS EQUIPMENT ON A GROUNDED SYSTEM ONLY.PRIMARY SINGLE PHASE FAILURE PROTECTION IS PROVIDED.

LE MODULE DU DISPOSITIF DE PROTECTION ET LE CHAUFFE-CARTERFACULTATIF DOIVENT ETRE BRANCHES A LA TENSION NOMINALEAPPROPRIEE.

EMPLOYER CET EQUIPEMENT SEULEMENT SUR SYSTEME MIS A LA TERRE.PROTECTION PRIMAIRE MONOPHASEE FOURNIE.

LE TYPE ET LES CARACTERISTIQUES NOMINALES DU DISPOSITIF DEPROTECTION CONTRE LES SURINTENSITES DOIVENT ETRE CONFORMES AUXEXIGENCES DES POUVOIRS DE REGLEMENTATION VISANT LE PRODUIT FINI-VOIR LA PLAQUE SIGNALETIQUE.

SCHUTZGER-T UND KURBELGEH-USEHEIZER (FALLS VORHANDEN)D_RFEN NUR MIT NENNSPANNUNG BETRIEBEN WERDEN.NENNLEISTUNG UND TYP DES _BERSTROMSCHUTZSCHALTERS M_SSENIN _BEREINSTIMMUNG MIT ZUTREFFENDEN VORSCHRIFTEN SEIN-BITTE TYPENSCHILD BEACHTEN.

NOTE:SOLID STATE MODULE HAS 30 MINUTESTIME DELAY BEFORE RESET IN EVENTOF PROTECTOR TRIP.

052-1201-00

INTERNAL THERMALSENSORS/CAPTEURS THERMIQUESINTERNES/INTERNETEMPERATURSENSOREN

TO CONTROL CIRCUIT/VERS LE CIRCUIT DECOMMANDE/ZUM STEUERSTROMKREIS

PROTECTOR MODULE VOLTAGE/TENSION DU MODULE DU DISPOSITIFDE PROTECTION/ANSCHLUSSPANNUNG DES SCHUTZGER-TES1

2

L1

MOTOR WINDINGCONNECTIONS/BORNES DESENROULEMENTS DUMOTEUR/ANSCHLUSSDER MOTORWICKLUNGEN

L2

L3

L1 L2L321

T2 S2 S1 M2 M1T1

OVERCURRENT PROTECTION DEVICE RATING AND TYPE MUSTBE IN ACCORDANCE WITH REGULATION AND PRODUCT APPROVALS-SEE SYSTEM NAMEPLATE.

ANLAGE NUR MIT ERDUNG VERWENDEN.SCHUTZ BEI PHASENAUSFALL AUF DER PRIM-RSEITE ISTGEW-HRLEISTET.

G58

Wiring Diagram 005-1211-01

CONNECTOCONNECTOR R BLOCBLOCK K (WHEN REQD(WHEN REQD) )

USEUSE COPPERCOPPER CONDUCTORCONDUCTORS S ONLYONLY. .

T1 T2

T3

USE MINIMUM 75 C WIRE FOUSE MINIMUM 75 C WIRE FOR R AMPACITY DETERMINATIONAMPACITY DETERMINATION. . PRIMARY SINGLE PHASE FAILURPRIMARY SINGLE PHASE FAILURE E PROTECTION IS PROVIDEDPROTECTION IS PROVIDED. . INTERNAL MOTOR PROTECTION-ALLOINTERNAL MOTOR PROTECTION-ALLOW W TIME FOR RESETTIME FOR RESET. . CRANKCASE HEATER, WHEN APPLIEDCRANKCASE HEATER, WHEN APPLIED, , MUST BE CONNECTED ONLY TO ITMUST BE CONNECTED ONLY TO ITS S RATED VOLTAGERATED VOLTAGE. .

USE THIS EQUIPMENT ON USE THIS EQUIPMENT ON A A GROUNDED SYSTEM ONLYGROUNDED SYSTEM ONLY. .

OVERCURRENT PROTECTION DEVICOVERCURRENT PROTECTION DEVICE E RATING AND TYPE MUST BE IRATING AND TYPE MUST BE IN N ACCORDANCE WITH REGULATORY AGENCACCORDANCE WITH REGULATORY AGENCY Y END PRODUCT APPROVALS- SEE SYSTEEND PRODUCT APPROVALS- SEE SYSTEM M NAMEPLATENAMEPLATE. .

MOTOR WINDINMOTOR WINDING G CONNECTIONCONNECTIONS S

1

2 3

005-

1211

-01

8-

06

G59

Wiring Diagram 005-1213

8-06

00

5-12

13-0

0

G60

Wiring Diagram 1223

USE MINIMUM 75C COPPER

WIRE FOR AMPACITY

DETERMINATION.

WHEN PROVIDED, CRANKCASE

HEATER AND FAN MUST BE

CONNECTED ONLY TO THEIR

RATED VOLTAGE.

SYSTEM OVERCURRENT

PROTECTION DEVICE RATING AND

TYPE MUST BE IN ACCORDANCE

WITH REGULATORY AGENCY

END PRODUCT APPROVALS

-SEE SYSTEM NAMEPLATE.

8-02 052-1223-00

RED

START CAPACITOR

CURRENT

RELAY

LINE

BLACK

YELLOW

BLAC

KKCALB

BLACK

4

21

EXTERNAL

PROTECTOR

R

C

S

LINE GND

LINE (230V)

NEUTRAL (115V)

FAN

G61

Wiring Diagram 005-1270

8-06

00

5-12

70-0

0

G62

Wiring Diagram 005-1271

G63

Wiring Diagram 1318

G64

Wiring Diagram 1319

G65

Wiring Diagram 1851

G66

Wiring Diagram 1852

G67

This page is left blank intentionally.

G68

Wiring Diagram 2167 (Left Side)

G69

Wiring Diagram 2167 (Right Side)

G70

Wiring Diagram 2169 (Top)

G71

Wiring Diagram 2169 (Bottom)

G72

Wiring Diagram 2170 (Top)

G73

Wiring Diagram 2170 (Bottom)

G74

Wiring Diagram 2177 (Left Side)

G75

Wiring Diagram 2177 (Right Side)

G76

DiscontinuedWiring Diagram 005-0492, 0637

G77

DiscontinuedWiring Diagram 005-0655, 0697

G78

DiscontinuedWiring Diagram 005-0678-00, 005-0679-00

G79

DiscontinuedWiring Diagram 005-0706

G80

DiscontinuedWiring Diagram 0716

G81

This page is left blank intentionally.

G82

DiscontinuedWiring Diagram 0748 (Left Side)

G83

DiscontinuedWiring Diagram 0748 (Right Side)

G84

DiscontinuedWiring Diagram 0751

G85

DiscontinuedWiring Diagram 0752

G86

DiscontinuedWiring Diagram 0756

G87

DiscontinuedWiring Diagram 0757

G88

DiscontinuedWiring Diagram 0758

G89

DiscontinuedWiring Diagram 0759

G90

DiscontinuedWiring Diagram 0760

G91

This page is left blank intentionally.

G92

DiscontinuedWiring Diagram 0762 (Left Side)

G93

DiscontinuedWiring Diagram 0762 (Right Side)

G94

DiscontinuedWiring Diagram 0763 (Left Side)

G95

DiscontinuedWiring Diagram 0763 (Right Side)

G96

DiscontinuedWiring Diagram 0765 (Left Side)

G97

DiscontinuedWiring Diagram 0765 (Right Side)

G98

DiscontinuedWiring Diagram 005-0777

G99

DiscontinuedWiring Diagram 0784

G100

DiscontinuedWiring Diagram 005-0788

G101

DiscontinuedWiring Diagram 005-0799-00, 005-0800-00

005-

0799

-00

4-

95

G102

DiscontinuedWiring Diagram 005-0800-01

CONNECTOCONNECTOR R BLOCBLOCK K (WHEN REQD(WHEN REQD) )

USEUSE COPPERCOPPER CONDUCTORCONDUCTORS S ONLYONLY. .

T1 T2

T3

USE MINIMUM 75 C WIRE FOUSE MINIMUM 75 C WIRE FOR R AMPACITY DETERMINATIONAMPACITY DETERMINATION. . PRIMARY SINGLE PHASE FAILURPRIMARY SINGLE PHASE FAILURE E PROTECTION IS PROVIDEDPROTECTION IS PROVIDED. . INTERNAL MOTOR PROTECTION-ALLOINTERNAL MOTOR PROTECTION-ALLOW W TIME FOR RESETTIME FOR RESET. . CRANKCASE HEATER, WHEN APPLIEDCRANKCASE HEATER, WHEN APPLIED, , MUST BE CONNECTED ONLY TO ITMUST BE CONNECTED ONLY TO ITS S RATED VOLTAGERATED VOLTAGE. .

USE THIS EQUIPMENT ON USE THIS EQUIPMENT ON A A GROUNDED SYSTEM ONLYGROUNDED SYSTEM ONLY. .

OVERCURRENT PROTECTION DEVICOVERCURRENT PROTECTION DEVICE E RATING AND TYPE MUST BE IRATING AND TYPE MUST BE IN N ACCORDANCE WITH REGULATORY AGENCACCORDANCE WITH REGULATORY AGENCY Y END PRODUCT APPROVALS- SEE SYSTEEND PRODUCT APPROVALS- SEE SYSTEM M NAMEPLATENAMEPLATE. .

MOTOR WINDINMOTOR WINDING G CONNECTIONCONNECTIONS S

1

2 3

005-

0800

-01

4-

95

G103

DiscontinuedWiring Diagram 0801

G104

DiscontinuedWiring Diagram 0811

W3

U1

V2

Y5

X4

Z6

SENSOR

SENSORS

M1

M2

T1

T2

LINE

L1

L2

L3

W3

U1

V2

Y5

X4

Z6

CONTROL

CIRCUIT

SENSOR

SENSORS

MAI

MAIN

SS1

PROTECTOR MODULE AND OPTIONA

PROTECTOR MODULE AND OPTIONAL

CRANKCASE HEATER MUST BE CONNECTE

CRANKCASE HEATER MUST BE CONNECTED

ONLY TO THEIR RATED VOLTAGE

ONLY TO THEIR RATED VOLTAGE.

USE COPPER CONDUCTORS ONLY

USE COPPER CONDUCTORS ONLY.

PRIMARY SINGLE PHASE FAILUR

PRIMARY SINGLE PHASE FAILURE

PROTECTION IS PROVIDED

PROTECTION IS PROVIDED.

USE THIS EQUIPMENT ON A GROUNDE

USE THIS EQUIPMENT ON A GROUNDED

SYSTEM ONLY

SYSTEM ONLY.

9-93 052-0811-0

9-93 052-0811-00

USE MINIMUM 75 C WIRE FO

USE MINIMUM 75 C WIRE FOR

AMPACITY DETERMINATION

AMPACITY DETERMINATION.

MOTOR WINDIN

MOTOR WINDING

CONNECTION

CONNECTIONS

14

25

6 3

M1

M2

T1

T2

LINE

CONTROL

CIRCUIT

XSS1

X

WHEN CHECKING SOLID STATE MODULE

WHEN CHECKING SOLID STATE MODULE:

USE OHMMETER ONLY (6 VOLTS MAXIMUM) T

USE OHMMETER ONLY (6 VOLTS MAXIMUM) TO

CHECK SENSOR RESISTANCE. DO NOT SHOR

CHECK SENSOR RESISTANCE. DO NOT SHORT

ACROSS THE TERMINALS

ACROSS THE TERMINALS.

RESISTANCE ACROSS MOTOR SENSORS SHOUL

RESISTANCE ACROSS MOTOR SENSORS SHOULD

BE APPROXIMATELY 1500 T0 7800 OHM

BE APPROXIMATELY 1500 T0 7800 OHMS

WITH A MOTOR TEMPERATURE BELOW 60 C

WITH A MOTOR TEMPERATURE BELOW 60 C.

L1

L2

L3

MAI

MAIN

STAR CONNECTE

STAR CONNECTED

DELTA CONNECTE

DELTA CONNECTED

OVERCURRENT PROTECTION DEVIC

OVERCURRENT PROTECTION DEVICE

RATING AND TYPE MUST BE I

RATING AND TYPE MUST BE IN

ACCORDANCE WITH REGULATOR

ACCORDANCE WITH REGULATORY

AGENCY END PRODUCT APPROVALS

AGENCY END PRODUCT APPROVALS-

SEE SYSTEM NAMEPLATE

SEE SYSTEM NAMEPLATE.

PROTECTOR MODUL

PROTECTOR MODULE

VOLTAG

VOLTAGE

TO CONTRO

TO CONTROL

CIRCUI

CIRCUIT

PROTECTOR MODUL

PROTECTOR MODULE

VOLTAG

VOLTAGE

TO CONTRO

TO CONTROL

CIRCUI

CIRCUIT

G105

DiscontinuedWiring Diagram 0813

G106

DiscontinuedWiring Diagram 0815

G107

DiscontinuedWiring Diagram 005-0819

G108

DiscontinuedWiring Diagram 0823

PROTECTOR MODULE AND OPTIONALCRANKCASE HEATER MUST BE CONNECTEDONLY TO THEIR RATED VOLTAGE.

USE COPPER CONDUCTORS ONLY.

PRIMARY SINGLE PHASE FAILUREPROTECTION IS PROVIDED.

USE THIS EQUIPMENT ON A GROUNDEDSYSTEM ONLY.

6-00 052-0883-00

USE MINIMUM 75 C WIRE FORAMPACITY DETERMINATION.

MOTOR WINDINGCONNECTIONS

WHEN CHECKING PROTECTORUSE OHMMETER ONLY (6 VOLTS MAXIMUM)TO CHECK SENSOR RESISTANCE. DO NOTSHORT ACROSS THE TERMINALS.

RESISTANCE ACROSS MOTOR SENSORS SHOULDBE APPROXIMATELY 750 OHMS WITH A MOTORTEMPERATURE BELOW 60 C.

OVERCURRENT PROTECTION DEVICERATING AND TYPE MUST BE INACCORDANCE WITH REGULATORYAGENCY END PRODUCT APPROVALS-SEE SYSTEM NAMEPLATE.

U1

Y5X4 V2

Z6

W3

SENSORS 120 OR 240 VOLT MODULE WIRING120 OR 240 VOLT MODULE WIRING

**THE 40AA300E MODULE HAS A FOUR MINUTETIME DELAY BEFORE RESET IN EVENT OFPROTECTOR TRIP OR LOSS OF MODULE POWER.THE 40AA100E MODULE IS NOT FURNISHEDWITH A TIME DELAY DEVICE.

L1 L2 L3

W3

V2 Y5X4

Z6

MAINL1 L2 L3

U1 V2 Y5X4

MAIN

S1

M1 L1

S2

TO CONTROLCIRCUIT

L2U1

W3 Z6

PROTECTORMODULEVOLTAGE

PROTECTORMODULEVOLTAGE

L2

TO CONTROLCIRCUIT

L1M1

S1S2

M2

X

M2

X

SENSORS

DELTA CONNECTED STAR CONNECTED

PART No. 40AA300E**

PART No. 40AA300E**

G109

DiscontinuedWiring Diagram 0824

G110

DiscontinuedWiring Diagram 0825

G111

DiscontinuedWiring Diagram 0826

G112

DiscontinuedWiring Diagram 005-0837

G113

DiscontinuedWiring Diagram 005-0838

G114

DiscontinuedWiring Diagram 005-0840

G115

This page is left blank intentionally.

G116

DiscontinuedWiring Diagram 0841 (Left Side)

G117

DiscontinuedWiring Diagram 0841 (Right Side)

G118

DiscontinuedWiring Diagram 0848

G119

DiscontinuedWiring Diagram 0849

G120

DiscontinuedWiring Diagram 0853 (Left Side)

G121

DiscontinuedWiring Diagram 0853 (Right Side)

G122

DiscontinuedWiring Diagram 0854 (Top)

G123

DiscontinuedWiring Diagram 0854 (Bottom)

G124

DiscontinuedWiring Diagram 0855

G125

This page is left blank intentionally.

G126

DiscontinuedWiring Diagram 0856 (Top)

G127

DiscontinuedWiring Diagram 0856 (Bottom)

G128

DiscontinuedWiring Diagram 0857 (Left Side)

G129

DiscontinuedWiring Diagram 0857 (Right Side)

G130

DiscontinuedWiring Diagram 0858 (Top)

G131

DiscontinuedWiring Diagram 0858 (Bottom)

G132

DiscontinuedWiring Diagram 0859 (Left Side)

G133

DiscontinuedWiring Diagram 0859 (Right Side)

G134

DiscontinuedWiring Diagram 005-0860

XX

USE COPPER CONDUCTORS ONLY. USETHIS EQUIPMENT ON A GROUNDEDSYSTEM ONLY. USE MINIMUM 75CWIRE FOR AMPACITY DETERMINATION.INTERNAL MOTOR PROTECTION-ALLOW TIME FOR RESET.OVERCURRENT PROTECTION DEVICERATING AND TYPE MUST BE INACCORDANCE WITH REGULATORY AGENCYEND PRODUCT APPROVALS-SEE SYSTEMNAMEPLATE.

00-

068

0-5

00

6

9-3

RS

CLINE

LINE

RUN CAPACITOR

G135

DiscontinuedWiring Diagram 005-0868

G136

DiscontinuedWiring Diagram 0874

G137

DiscontinuedWiring Diagram 0875

G138

DiscontinuedWiring Diagram 0876

G139

DiscontinuedWiring Diagram 0882

G140

DiscontinuedWiring Diagram 0883

G141

DiscontinuedWiring Diagram 0884

G142

DiscontinuedWiring Diagram 0885

G143

This page is left blank intentionally.

G144

DiscontinuedWiring Diagram 0896 (Left Side)

G145

DiscontinuedWiring Diagram 0896 (Right Side)

G146

DiscontinuedWiring Diagram 0898 (Top)

G147

DiscontinuedWiring Diagram 0898 (Bottom)

G148

DiscontinuedWiring Diagram 0899 (Top)

G149

DiscontinuedWiring Diagram 0899 (Bottom)

G150

DiscontinuedWiring Diagram 0902 (Left Side)

G151

DiscontinuedWiring Diagram 0902 (Right Side)

G152

DiscontinuedWiring Diagram 0917

G153

DiscontinuedWiring Diagram 0918

1-00 052-0918-00

LINE

SENSORS

USE COPPER CONDUCTORS ONLY.USE MINIMUM 75 C WIRE FOR AMPACITY DETERMINATION.

T1 T7

T2

T8

USE THIS EQUIPMENT ON A GROUNDED SYSTEM ONLY.PROTECTOR MODULE AND OPTIONAL CRANKCASE HEATER MUST BECONNECTED ONLY TO THEIR RATED VOLTAGE.

MOTOR WINDINGCONNECTIONS

NI

AM LANR

ET

XE

GNI

DN

IW

NIA

M

TRATS

EL

OP 4

TR

AT

S

EL

OP 2

T3

T8T7T2

T1

TWO SPEED SINGLE PHASE

LINE

T1 T7

T2

T3 T8

OVERCURRENT PROTECTION DEVICE RATING AND TYPE MUST BE INACCORDANCE WITH REGULATORY AGENCY END PRODUCT APPROVALS-SEESYSTEM NAMEPLATE.

LOW SPEED HIGH SPEED

SEE SYSTEM MANUFACTURER'S WIRING DIAGRAM FOR STARTCOMPONENT CONNECTIONS.

T3

PROTECTORMODULEVOLTAGE

TO CONTROLCIRCUIT

L1 L2 S1 S2 M1 M2Part-No. XXXXXX

G154

DiscontinuedWiring Diagram 0919

LINEHIGH SPEED

SENSORS

T4 T5

T6

MOTOR WINDINGCONNECTIONS

T1 T2

T3

T4

T1

T6T2T5

T3

LINELOW SPEED

T1 T2

T3

T4 T5

T6

TWO SPEED THREE PHASE

PROTECTOR MODULE AND OPTIONAL CRANKCASE HEATER MUSTBE CONNECTED ONLY TO THEIR RATED VOLTAGE.

USE THIS EQUIPMENT ON A GROUNDED SYSTEM ONLY.USE MINIMUM 75 C WIRE FOR AMPACITY DETERMINATION.USE COPPER CONDUCTORS ONLY.

PRIMARY SINGLE PHASE FAILURE PROTECTION IS PROVIDED.

OVERCURRENT PROTECTION DEVICE RATING AND TYPE MUST BEIN ACCORDANCE WITH REGULATORY AGENCY END PRODUCTAPPROVALS-SEE SYSTEM NAMEPLATE. 1-00 052-0919-00

PROTECTORMODULEVOLTAGE

TOCONTROLCIRCUIT

L1 L2 S1 S2 M1 M2Part-No. XXXXXX

G155

DiscontinuedWiring Diagram 005-0922

G156

DiscontinuedWiring Diagram 0948

052-0948-006-00

MOTOR WINDINGCONNECTIONS

MAIN

1 2

3

PROTECTOR MODULE AND OPTIONAL CRANKCASE HEATER MUSTBE CONNECTED ONLY TO THEIR RATED VOLTAGE.

USE COPPER CONDUCTORS ONLY.

PRIMARY SINGLE PHASE FAILURE PROTECTION IS PROVIDED.

USE THIS EQUIPMENT ON A GROUNDED SYSTEM ONLY.

USE MINIMUM 75 C WIRE FOR AMPACITY DETERMINATION.

1

2

3

L1 L2 L3

OVERCURRENT PROTECTION DEVICE RATING AND TYPE MUST BEIN ACCORDANCE WITH REGULATORY AGENCY END PRODUCTAPPROVALS-SEE SYSTEM NAMEPLATE.

SENSORS

TO CONTROLCIRCUIT

PROTECTORMODULEVOLTAGE

WHEN CHECKING PROTECTORUSE OHMMETER ONLY (6 VOLTS MAXIMUM) TO CHECK SENSORRESISTANCE. DO NOT SHORT ACROSS THE TERMINALS.

RESISTANCE ACROSS MOTOR SENSORS SHOULD BEAPPROXIMATELY 750 OHMS WITH A MOTOR TEMPERATUREBELOW 60 C.

**THE 40AA300E MODULE HAS A FOUR MINUTE TIME DELAYBEFORE RESET IN EVENT OF PROTECTOR TRIP OR LOSS OFMODULE POWER.THE 40AA100E MODULE IS NOT FURNISHED WITH A TIME DELAYDEVICE.

120 OR 240 VOLT MODULE WIRING

M1 M2 L1 L2

X S1 S2

PART No. 40AA300E**

G157

DiscontinuedWiring Diagram 0949

L1 L2 L3

W3

V2 Y5X4

Z6

SENSORS

MAIN

PROTECTOR MODULE AND OPTIONALCRANKCASE HEATER MUST BE CONNECTEDONLY TO THEIR RATED VOLTAGE.

USE COPPER CONDUCTORS ONLY.

PRIMARY SINGLE PHASE FAILUREPROTECTION IS PROVIDED.

USE THIS EQUIPMENT ON A GROUNDEDSYSTEM ONLY.

6-00 052-0949-00

USE MINIMUM 75 C WIRE FORAMPACITY DETERMINATION.

MOTOR WINDINGCONNECTIONS

L1 L2 L3

U1 V2 Y5X4

SENSORS

MAIN

OVERCURRENT PROTECTION DEVICERATING AND TYPE MUST BE INACCORDANCE WITH REGULATORYAGENCY END PRODUCT APPROVALS-SEE SYSTEM NAMEPLATE.

U1

W3 Z6

U1

Y5X4 V2

Z6

W3

DELTA CONNECTED STAR CONNECTED

WHEN CHECKING PROTECTORUSE OHMMETER ONLY (6 VOLTS MAXIMUM)TO CHECK SENSOR RESISTANCE. DO NOTSHORT ACROSS THE TERMINALS.

RESISTANCE ACROSS MOTOR SENSORS SHOULDBE APPROXIMATELY 750 OHMS WITH A MOTORTEMPERATURE BELOW 60 C.

**THE 40AA300E MODULE HAS A FOUR MINUTETIME DELAY BEFORE RESET IN EVENT OFPROTECTOR TRIP OR LOSS OF MODULE POWER.THE 40AA100E MODULE IS NOT FURNISHEDWITH A TIME DELAY DEVICE.

120 OR 240 VOLT MODULE WIRING120 OR 240 VOLT MODULE WIRING

TO CONTROLCIRCUIT

PROTECTORMODULEVOLTAGE

M1 M2 L2L1

S2S1X S1

M1 L1

TO CONTROLCIRCUIT

L2

PROTECTORMODULEVOLTAGE

S2

M2

X

PART No. 40AA300E**

PART No. 40AA300E**

G158

DiscontinuedWiring Diagram 005-1043

G159

DiscontinuedWiring Diagram 005-1062

G160

DiscontinuedWiring Diagram 005-1071

G161

DiscontinuedWiring Diagram 1196

G162

DiscontinuedWiring Diagram 1299 (Left Side)

G163

DiscontinuedWiring Diagram 1299 (Right Side)

G164

DiscontinuedWiring Diagram 1825, 0700-8503514