sdc - 310 switching mode step up converter mode step up converter ... conversion technology allows 2...

2
anson M LEAD ACID BATTERY CHARGER HBC - 1110 / 1115 / 1120 12V Advanced Multi-Stage Battery Charger with MCU All values are based on the Standard ambient Temperature 25°C and Pressure 0.1Mpa. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE Description Features This series of advanced battery chargers are designed to cover a wide range of battery capacities and battery types. The Micro-Processor Control allows for easy selective charging operations to ensure quick and full charge for your battery type. Smart and extensive fail safe protections plus the thermally controlled charging current make this charger dependable and durable even in adverse ambient conditions. There are essentially 5 charging stages: Soft Bulk, Bulk, Absorption, Float and Standby (power saving). In addition there is a manual or auto Equalization Charge for Flooded battery. The MCU constantly monitors the battery status at all times, it counts the days for auto-Equalization Charge, and days in both Float, Standby mode for auto-recycle charge to keep battery fresh even in long period of inactive service. The soft-ware based power conversion technology allows 2 specific charging profiles be programmed via the USB port from a PC. This user defined charging function is ideal for special charging requirement and other chemical type of battery such as lithium iron phosphate. MCU control software based adaptive 5 stage charging for Wet, LiFePo4, Gel, AGM, Calcium –Calcium lead acid battery. Selection of battery type & max. charging current either by optional remote panel or by PC . Model HBC -1140 and -1160 have two isolated charging terminal with separate voltage detect and total current detect capability. All other models have only one charging terminal. Optional remote control panel display of : voltage at each terminal, total current, Charging stage, total operation hours, max output set and fault type. Extensive protection for charger and battery: over charging voltage, charger over temperature, battery over temperature, cooling fan malfunction. Thermal decrease of charger output power to ensure safe operation temperature for the components in hot ambient environment . Optional Accessory: Remote Control Panel (HBR-3100)

Upload: vunga

Post on 13-Jun-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

ansonM DC - DC CONVERTERSDC - 310Switching Mode Step Up Converter

ansonMLEAD ACID BATTERY CHARGERHBC - 1110 / 1115 / 112012V Advanced Multi-Stage Battery Charger with MCU

◘ All values are based on the Standard ambient Temperature 25°C and Pressure 0.1Mpa.◘ SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

Description

Features

This series of advanced battery chargers are designed to cover a wide range of battery capacities and battery types. The Micro-Processor Control allows for easy selective charging operations to ensure quick and full charge for your battery type. Smart and extensive fail safe protections plus the thermally controlled charging current make this charger dependable and durable even in adverse ambient conditions.

There are essentially 5 charging stages: Soft Bulk, Bulk, Absorption, Float and Standby (power saving). In addition there is a manual or auto Equalization Charge for Flooded battery.The MCU constantly monitors the battery status at all times, it counts the days for auto-Equalization Charge, and days in both Float, Standby mode for auto-recycle charge to keep battery fresh even in long period of inactive service.

The soft-ware based power conversion technology allows 2 specific charging profiles be programmed via the USB port from a PC. This user defined charging function is ideal for special charging requirement and other chemical type of battery such as lithium iron phosphate.

••

MCU control software based adaptive 5 stage charging for Wet, LiFePo4, Gel, AGM, Calcium –Calcium lead acidbattery. Selection of battery type & max. charging current either by optional remote panel or by PC .Model HBC -1140 and -1160 have two isolated charging terminal with separate voltage detect and total currentdetect capability. All other models have only one charging terminal. Optional remote control panel display of : voltage at each terminal, total current, Charging stage, totaloperation hours, max output set and fault type.Extensive protection for charger and battery: over charging voltage, charger over temperature, battery overtemperature, cooling fan malfunction.Thermal decrease of charger output power to ensure safe operation temperature for the components in hotambient environment .

◘ All values are based on the Standard ambient Temperature 25°C and Pressure 0.1Mpa.◘ SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

Specifications

FeaturesDescription

Input Voltage Range

Output Voltage

Continuous Output Current

Ripple & Noise (r.m.s.)

Maximum Output Current

Load Regulation (0-100% load)

Line Regulation (10-15V variation)

Efficiency

Protection Devices

Cooling System

Indicators

Output Connection Type

Input Connection Type

e-Mark Approvals

Input Fuse Type

Dimensions (WxHxD)

Weight

Accessory

Models SDC - 310

8A

10A

300mV

150mV

10 - 16VDC

28VDC ±0.5VDC

<5mV

>88%

Overload, Short Circuit

Natural Convection

Power on LED

One set banana screw on type and one set philips screw type

Cable

e11 02 2981

Standard Car Blade Fuse

156x57x130 mm 6.1x2.2x5.1 inch

1 kg 2.2 lbs

Mounting Bracket

This series of DC-DC Switching Mode Converters are built to meet the high current applications at 28V DC. In addition to the high efficiency, the low profile construction makes use of the heat sinks as main body of the robust, rugged housing of the unit. The OVP (Over Voltage Protection) protects sensitive electronic equipment.

•••••••

High efficiency 88%High power densityOutput over voltage protectionShort circuit and overload protectionLED power on indicatorEMC INTERFERENCE IMMUNITYPower ON - OFF Switch

Optional Accessory:Remote Control Panel (HBR-3100)

DC - DC CONVERTERSSDC - 221513.8VDC Isolated Step Down Converter

ansonM ansonM

◘ All values are based on the Standard ambient Temperature 25°C and Pressure 0.1Mpa.◘ SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

Specifications

FeaturesDescription

Input Voltage Range

Output Voltage

Continuous Output Current

Ripple & Noise (r.m.s.)

Load Regulation (0-100% load)

Line Regulation (22.5-30V Variation)

Efficiency

Protection Devices

Cooling System

Indicators

Output Connection Type

Input Connection Type

CE Approvals

Input Fuse Type

Dimensions (WxHxD)

Weight

Accessory

Models SSDC - 2215

15A

100mV

100mV

22 - 30VDC

13.8VDC

>86%

Overload, Short Circuit

Natural Convection

Power ON LED

Terminal

Cable

Standard Car Blade Fuse

156x57x127 mm 6.1x2.2x5 inch

1.2 kg 4.4 lbs

Mounting Bracket

EN 55022

<10mV

This input and output isolated DC-DC voltage reducer is designed for negative, positive and floating ground dc system and loads that requires galvanic isolation between the input source and the active loads. The switching mode conversion results high operation efficiency with low standby current. The power on off switch provides further conservation of energy for long period of inactive operation.

••••••••

Output and input isolated Low standby current High Efficiency 86%Protection against transient voltagesEMC interference immunityOverload & short circuit Protection LED power on and fault indicator Supplied with Mounting brackets.

No Load Input Current

Full Load Input Current

100mA

10A

Housing Material Anodized Aluminum

LEAD ACID BATTERY CHARGERHBC - 1110 / 1115 / 112012V Advanced Multi-Stage Battery Charger with MCU

Recommended Battery Capacity Range

Included Accessories (spare fuse, temperature sensor)

Optional Accessories (remote control panel)

Weight

Dimension (WxHxD)

Plastic panel & Electro-galvanized steel housing w/Mounting flange

Charge Cycle, Protection Indication

Approvals

Separate LED for Bulk, Absorption, Float and Fault Mode

Charger ON / OFF LED Indicator

Power ON / OFF Switch

Remote Control & Temperature Sensor Socket

Thermostatically Controlled Variable Speed Fan (0 - full speed)

Thermal decrease of charger output power

OVP (Output Tracking/ Fixed Over Voltage Protection Selectable)

Over Temperature Protection

Reverse Polarity Protection (fused)

Overload Protection

Short Circuit Protection

Efficiency at WET (230VAC)

Ripple & Noise (Peak to Peak)

Maximum Output Charging Current (continuous)

Battery Voltage to Trigger (cut-in) Soft Start Bulk Charge Mode

Soft Start Bulk Charge Current Level (current limit)

Soft Start Bulk Charge

WET

LiFePO4

AGM

GEL 1

GEL 2

CALCIUM

User Define 1

User Define 2

Equalization

AC Input Current at Full Load (at 230 / 100 AC)

AC Input Voltage 100 - 240VAC, 50/60Hz~

Model

Output (Charge) Voltage Selections

Protections

16AH to 100AH

Yes

Not Included Not Included Not Included

2.5 kg

200x80x250 mm

Yes

CE EN 60335 EN 55014 EN 62233

Yes Yes Yes

Yes Yes Yes

Yes Yes Yes

Yes Yes Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

>78%

<200mV

<12.3V

1/2 of the charging current

1A / 2A

Absorption

14.4V

14.6V

14.3V

14.1V

14.3V

15.1V

12V - 16V

12V - 16V

15.5V

Yes

10A

HBC - 1110

24AH to 150AH

Yes

2.6 kg

200x80x250 mm

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

1.5A / 3A

Yes

15A

HBC - 1115

32AH to 200AH

Yes

2.6 kg

200x80x250 mm

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

2A / 4A

Yes

20A

HBC - 1120

Float

13.5V

13.6V

13.2V

13.7V

13.8V

13.8V

Specifications

>80% >80%

◘ All values are based on the Standard ambient Temperature 25°C and Pressure 0.1Mpa.◘ SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE