SD-WAN 2.2 Silver Peak Collector Installation Guide
08 March 2019Version 1.2
Table of Contents
1 Introduction 3
2 Prerequisites 3
2.1 Resources and Other Requirements 4
2.2 Network Requirements 4
3 NMS Appliance Setup 5
4 Installation Steps 10
4.1 Verify that Data Appears in SevOne NMS 17
5 Useful Commands 19
SD-WAN 2.2 Silver Peak Collector Installation Guide
3 of 20
SevOne Documentation
All documentation is available from the .SevOne Support customer portal
Copyright ©2019 SevOne Inc. All rights reserved worldwide.
All right, title, and interest in and to the software and documentation are and shall remain the exclusive property of
SevOne and its respective licensors. No part of this document may be reproduced by any means nor modified,
decompiled, disassembled, published or distributed, in whole or in part, or translated to any electronic medium or
other means without the written consent of SevOne.
In no event shall SevOne, its suppliers, nor its licensors be liable for any damages, whether arising in tort, contract,
or any other legal theory even if SevOne has been advised of the possibility of such damages, and SevOne
disclaims all warranties, conditions, or other terms, express or implied, statutory or otherwise, on software and
documentation furnished hereunder including without limitation the warranties of design, merchantability, or fitness
for a particular purpose, and noninfringement.
All SevOne marks identified or used on the SevOne website, as updated by SevOne from time to time, may be, or
are, registered with the U.S. Patent and Trademark Office and may be registered or pending registration in other
countries. All other trademarks or registered trademarks contained and/or mentioned herein are used for
identification purposes only and may be trademarks or registered trademarks of their respective companies.
1 Introduction
This document covers the installation of the SD-WAN Silver Peak Collector using SevOne NMS 5.7.2.6 and
SevOne Data Insight 1.5.3.
2 Prerequisites
In order to install the collector, you need to contact SevOne's Production Team for the tar file, sdwan- -silverpeak
. The tar must contain following components:installation-<release-tag>.tar.gz
Docker Installation files and dependencies
Silver Peak Collector (sdwan-silverpeak.tar.gz)
Ansible script to automate the installation/upgrade
For sdwan- -installation-<release-tag>.tar.gzsilverpeak , <release-tag> must be replaced with the SD-
WAN release version. For example, sdwan-silverpeak-installation-2.2.tar.gz
SD-WAN 2.2 Silver Peak Collector Installation Guide
4 of 20
2.1 Resources and Other Requirements
SevOne NMS Version 5.7.2.6
An administrator-level account in SevOne NMS. This is necessary in order for the SD-WAN 2.2 Silver Peak Collector to communicate with SevOne REST API.NMS
User name and password for the administrator-level account.
IP address of the PAS.
20k (vPAS_20K_CentOS) appliance (minimum requirement).
Data Insight Version 1.5.3
DSPlugin must be dsplugin-pas5x-1.5.3-hotfix.2.x86_64 .
Silver Peak Version 8.5.1.40371
Docker Version 18.06.1-ce
CPUs 4 or more
RAM 8 GB or more
Hard Disk Drive 20 GB or more
Other Crontab, Logrotate, Ansible Version 2.x
2.2 Network Requirements
2.2.1 Firewall Configuration
The following ports must be open for component access.
SD-WAN 2.2 Silver Peak Collector Installation Guide
5 of 20
2.2.2 Non-HSA Deployment
There are two option for non-HSA deployment.
Option 1: NMS and Collector are co-hosted.
Number of IP addresses needed: 2
IP for Data InsightD
IP for NMSN
Option 2: NMS and Collector are on separate hosts.
Number of IP addresses needed: 3
IP for Data InsightD
IP for NMSN
IP for CollectorC
3 NMS Appliance Setup
NMS appliance setup is only required if it is being done for the . If not, please skip this section.first time
SD-WAN 2.2 Silver Peak Collector Installation Guide
6 of 20
1.
Perform the following steps on your NMS appliance.
Using , login to NMS appliance as .ssh root
$ ssh root@<NMS appliance>
SD-WAN 2.2 Silver Peak Collector Installation Guide
7 of 20
2.
3.
Change hostname. Hit <Return> or provide a unique hostname.
$ SevOne-change-hostname
cat: /etc/hostname: No such file or directory
Current Hostname = . Enter New Hostname:
About to change hostname to
You have 4 seconds to press Ctrl-C to abort
sed: can't read /etc/hostname: No such file or directory
sed: -e expression #1, char 0: no previous regular expression
--- /etc/hostname:
cat: /etc/hostname: No such file or directory
--- /etc/hosts:
127.0.0.1 localhost
::1 localhost
127.0.0.1 localhost
--- Output of hostnamectl status:
Static hostname: n/a
Transient hostname: localhost
Icon name: computer-vm
Chassis: vm
Machine ID: 6fd9c385cd7c4d24a51a1b162f70dbbe
Boot ID: 8cda94813b5341dcaca22cac599310a4
Virtualization: vmware
Operating System: CentOS Linux 7 (Core)
CPE OS Name: cpe:/o:centos:centos:7
Kernel: Linux 3.10.0-693.17.1.el7.x86_64
Architecture: x86-64
If this cluster is configured to use host files for peer name resolution remember
to run SevOne-fix-hosts-file
=== Restarting Kafka.
kafka: stopped
kafka: started
=== I now highly recommend that you reboot.
SevOne-shutdown reboot
Execute the following command and type at prompt.yes
SD-WAN 2.2 Silver Peak Collector Installation Guide
8 of 20
3.
$ SevOne-fix-hosts-file
Placed a backup copy of the hosts file in /root/hosts.backup
--- appliance IP is 10.128.11.196
>>> Continue(yes/no)?
yes
--- moving on...
Creating new hosts file from scratch.
Restarting Kafka and Zookeeper
kafka: stopped
kafka: started
zookeeper: stopped
zookeeper: started
Done!!! If you have any issues, immediately copy your backup from /root
/backuphosts over /etc/hosts and restart Kafka
Your new /etc/hosts file:
# /etc/hosts: Local Host Database
#
# This file describes a number of aliases-to-address mappings for the for
# local hosts that share this file.
#
# In the presence of the domain name service or NIS, this file may not be
# consulted at all; see /etc/host.conf for the resolution order.
#
# IPv4 and IPv6 localhost aliases
127.0.0.1 localhost
::1 localhost
#
# Imaginary network.
#10.0.0.2 myname
#10.0.0.3 myfriend
#
# According to RFC 1918, you can use the following IP networks for private
# nets which will never be connected to the Internet:
#
# 10.0.0.0 - 10.255.255.255
# 172.16.0.0 - 172.31.255.255
# 192.168.0.0 - 192.168.255.255
#
# In case you want to be able to connect directly to the Internet (i.e. not
# behind a NAT, ADSL router, etc...), you need real official assigned
# numbers. Do not try to invent your own network numbers but instead get one
# from your network provider (if any) or from your regional registry (ARIN,
# APNIC, LACNIC, RIPE NCC, or AfriNIC.)
#
127.0.0.1 localhost
SD-WAN 2.2 Silver Peak Collector Installation Guide
9 of 20
3.
4.
5.
6.
Shutdown and reboot NMS appliance. If you do not want to reboot, you can execute supervisorctl restart
to ensure that Kafka service is up and running.kafka
$ SevOne-shutdown reboot
You will automatically log out from the appliance after executing this step.
After the shutdown and reboot, into the appliance again. Execute the following command to check the ssh
status of Kafka service.
$ ssh root@<NMS appliance>
$ supervisorctl status kafka
If Kafka service is not up and running, execute the following command to start the Kafka service.
$ supervisorctl restart kafka
Ensure all NMS services are running.
$ SevOne-act check checkout
[OK] No Errors Detected
SD-WAN 2.2 Silver Peak Collector Installation Guide
10 of 20
1.
2.
3.
4.
4 Installation Steps
The automation/ansible script must be executed on NMS appliance only.
Using , login to NMS appliance as .ssh root
$ ssh root@<NMS appliance>
Using scp, copy the tar file received from SevOne's Production Team (sdwan-silverpeak-installation-
<release-tag>.tar.gz) to directory of the NMS appliance./root
Extract the tar.gz file.
$ cd /root
$ mkdir sdwan-silverpeak-installation
$ tar -zxvf sdwan-silverpeak-installation-<release-tag>.tar.gz -C sdwan-silverpeak-
installation
$ cd sdwan-silverpeak-installation
Using the text editor of your choice, configure the variables in file.config.yaml
$ vi config.yaml
Example: config.yaml
# Collector Configuration
# True when Upgrade collector and for first time installation it would be false
collector_upgrade: 'false'
SD-WAN 2.2 Silver Peak Collector Installation Guide
11 of 20
4.
# ReRun Installer when Upgrade collector is true
run_installer: 'false'
# Collector installation to be done on remote/local machine
collector_install_mode: 'local'
collector_release_tag: 'replace_release_tag'
# Provide values for the following only if collector_install_mode is remote
collector_vm_ip: '' # <VM-IP>
collector_vm_username: '' # <ssh-username>
collector_vm_password: '' # <ssh-password>
# Client must provide the NMS details
sevone_api_host: '<Nms IP>' # NMS HostIP
sevone_api_user: 'admin' # NMS admin level login username
sevone_api_password: '' # NMS password
sevone_nms_rest_debug: 'false'
sevone_api_config_port: '80'
sevone_api_security: 'false'
log_severity: 'info'
sevone_api_collection_port: '80'
sevone_api_config_version: 'v2'
sevone_api_collection_version: 'v2'
# Client must provide the vendor specific data collector details.
silverpeak_host: '<Orchestrator IP or DNS>' # Tenant level Orchastrator Host
IP or DNS name
silverpeak_user: '' # Orchestrator username
silverpeak_password: '' # Orchestrator password
silverpeak_tenant: '' # Orchestrator tenant name
silverpeak_enable_https: 'True' # Configuration for enable https
msp_name: 'SILVERPEAK' # MSP Name
poller_threads: '50'
### Update these values when need to enable individual poller
# Preference is to set following flags to true, as it will run each poller in
separate container and will make it optimum
enable_interface_poller: 'true'
enable_tunnel_poller: 'true'
enable_device_summary_poller: 'true'
enable_interface_stat_poller: 'true'
enable_tunnel_stat_poller: 'true'
enable_metadata_poller: 'true'
# Update Interval values for respective pollers, in minutes
device_summary_poller_interval: '5'
interface_stat_poller_interval: '5'
tunnel_stat_poller_interval: '5'
metadata_poller_interval: '30'
SD-WAN 2.2 Silver Peak Collector Installation Guide
12 of 20
4.
# Redis version configuration
redis_version: '4.0.11'
redis_password: 'Silverpeak123!'
redis_port: '7934'
Predefined set of configuration variables for Silver Peak Collector in file.config.yaml
The configuration file config.yaml contains the default values for the environment variables. You
need to edit the configuration variables and save the file.
collector_upgrade - Flag to install or upgrade the collector. To the collector, set it to . upgrade true
For , it must be set to . The default value is .first time installation false false
run_installer - Flag to reinstall SD-WAN object/indicator types and exit when is collector_upgrade
set to true. The default value is .false
collector_release_tag - The collector release tag. The default value is .latest
collector_install_mode - The mode of installation for Silver Peak Collector. Value can be or remote
. The value must be set to for collector installation on another VM rather than the NMS local remote
VM. The default value is .local
collector_vm_ip - IP address of the Virtual Machine where collector needs to be installed. This value
must only be set if is set to .collector_install_mode remote
collector_vm_username - SSH username of the VM for collector installation. This value must only be
set if is set to .collector_install_mode remote
collector_vm_password - SSH password of the VM for collector installation. This value must only be
set if is set to .collector_install_mode remote
sevone_api_host - The IP address of the SevOne NMS Appliance. The default value is .localhost
sevone_api_user - The SevOne NMS user name for an administrator-level account. The default
value is .admin
sevone_api_password - The SevOne NMS password.
log-severity - Log Level. Value can be or or . The default value is .info debug warning info
sevone_api_config_version - The REST API version for the SevOne NMS PAS. The default value is
. .v2 This shouldn't be changed
sevone_api_collection_version - The REST API version for the SevOne NMS PAS. The default
value is . .v2 This shouldn't be changed
sevone_api_config_port - The API config port. HTTP on port 80 and HTTPS on port 443. Please set
value to . .80 This shouldn't be changed
sevone_api_collection_port - The API communication port. HTTP on port 80 and HTTPS on port
443. Please set value to . .80 This shouldn't be changed
sevone_api_security - SevOne REST API uses HTTPS by default. Please set value to
SD-WAN 2.2 Silver Peak Collector Installation Guide
13 of 20
4.
5.
silverpeak_host - The IP address of targeted tenant level Orchestrator.
_user silverpeak - Username for the tenant level Orchestrator.
_password silverpeak - Password for the tenant level Orchestrator.
_tenant silverpeak - Orchestrator tenant name.
silverpeak enable_https_ - The protocol for the targeted tenant level Orchestrator. The default value
is .true
msp_name - The MSP name to which the configured tenant level Orchestrator belongs to.
poller_threads - Threads to be used for polling. The default value is 50.
enable_interface_poller - (recommended) Flag to run the poller in a separate container for interface
better performance. The default value is .true
enable_interface_stat_poller - (recommended) Flag to run the poller in a separate interface stat
container for better performance. The default value is .true
enable_tunnel_poller - (recommended) Flag to run the poller in a separate container for tunnel
better performance. The default value is .true
enable_tunnel_stat_poller - (recommended) Flag to run the poller in a separate tunnel stat
container for better performance. The default value is .true
enable_device_summary_poller - (recommended) Flag to run the poller in a device summary
separate container for better performance. The default value is .true
enable_metadata_poller - (recommended) Flag to run the poller in a separate container metadata
for better performance. The default value is .true
interface_stat_poller_interval - Interval set in minutes to run the poller. The default interface stat
value is .5 minutes
tunnel_stat_poller_interval - Interval set in minutes to run the poller. The default value is tunnel stat
.5 minutes
device_summary_poller_interval - Interval set in minutes to run the poller. The device summary
default value is .5 minutes
metadata_poller_interval - Interval set in minutes to run the metadata poller. The default value is 30
.minutes
redis_version - Redis version. The default value is .4.0.11
Execute the following command to install the Silver Peak Collector.
$ ansible-playbook silverpeak.yml
While running the Silver Peak ansible script, when you receive the following prompt. The script please wait
automatically continues the execution after the pause.
SD-WAN 2.2 Silver Peak Collector Installation Guide
14 of 20
5.
SD-WAN 2.2 Silver Peak Collector Installation Guide
15 of 20
5.
a.
i.
ii.
b.
c.
Docker upgrade issue
In case of any error related to docker installation, check the docker version as shown below.
: fatal: [localhost]: FAILED! => {"changed": false, "msg": "Unable to start service docker: Example
Job for docker.service failed because the control process exited with error code. See \"systemctl
status docker.service\" and \"journalctl -xe\" for details.\n"}
Check docker version
$ docker version
Client:
Version: 18.06.1-ce
API version: 1.38
Go version: go1.10.3
Git commit: e68fc7a
Built: Tue Aug 21 17:23:03 2018
OS/Arch: linux/amd64
Experimental: false
Server:
Engine:
Version: 18.06.1-ce
API version: 1.38 (minimum version 1.12)
Go version: go1.10.3
Git commit: e68fc7a
Built: Tue Aug 21 17:25:29 2018
OS/Arch: linux/amd64
Experimental: false
The docker version must be . If not, run the following commands.18.06.1-ce
Reboot the VM to reflect the docker version changes.
Collector running on NMS: SevOne-shutdown reboot
Collector running on remote VM (i.e. not NMS): reboot
(using command as Verify the docker version for both client and server docker version
shown above) .has been updated to 18.06.1-ce
Execute the Silver Peak ansible script again to install the Silver Peak Collector.
$ ansible-playbook silverpeak.yml
SD-WAN 2.2 Silver Peak Collector Installation Guide
16 of 20
6.
7.
You can check the docker images for Silver Peak Collector have been imported using the following
command.
Check docker images for Silver Peak Collector
$ docker images
REPOSITORY TAG IMAGE
ID CREATED SIZE
docker.sevone.com/sc/collectors/silverpeak develop
5c735aede75a 19 minutes ago 216MB
redis 4.0.11
a38ee13679d8 3 months ago 83.4MB
In case of remote installation, please check the docker images on the remote appliance. You
can into the remote appliance and check if the dockers images for SD-WAN Silver Peak ssh
Collector are loaded.
You must be able to see the following docker containers running for Silver Peak Collector.
Check docker containers for Silver Peak Collector
$ docker ps
CONTAINER ID IMAGE COMMAND
CREATED STATUS PORTS NAMES
dc1be7c6ef0e redis:4.0.11 "docker-entrypoint.s…" 5 minutes
ago Up 5 minutes 6379/tcp, 0.0.0.0:7934->7934/tcp silverpeak-redis
There must be at least this container up and running. In case of remote installation, please
check the docker containers on the remote appliance. You can into the remote ssh
appliance and check if the docker containers for SD-WAN Silver Peak Collector are running.
Ansible script sets the cron jobs to run the collector and delete the containers.
SD-WAN 2.2 Silver Peak Collector Installation Guide
17 of 20
8.
1.
Execute the following command to ensure the are set and running.cronjobs
Check cronjobs set for Silver Peak Collector
$ crontab -l
#Ansible: silverpeak device summary poller
*/5 * * * * docker run --rm --net=host --env-file /opt/sdwan-silverpeak
/collector-poller-settings.env -e ENABLE_DEVICE_SUMMARY_POLLER=true docker.sevone.
com/sc/collectors/silverpeak:develop >> /var/log/sdwan-silverpeak
/silverpeak_device_summary_poller.log 2>&1
#Ansible: silverpeak interface poller
0 */6 * * * docker run --rm --net=host --env-file /opt/sdwan-silverpeak
/collector-poller-settings.env -e ENABLE_INTERFACE_POLLER=true docker.sevone.com/sc
/collectors/silverpeak:develop >> /var/log/sdwan-silverpeak
/silverpeak_interface_poller.log 2>&1
#Ansible: silverpeak tunnel poller
0 */6 * * * docker run --rm --net=host --env-file /opt/sdwan-silverpeak
/collector-poller-settings.env -e ENABLE_TUNNEL_POLLER=true docker.sevone.com/sc
/collectors/silverpeak:develop >> /var/log/sdwan-silverpeak/silverpeak_tunnel_poller
.log 2>&1
#Ansible: silverpeak interface stat poller
*/5 * * * * docker run --rm --net=host --env-file /opt/sdwan-silverpeak
/collector-poller-settings.env -e ENABLE_INTERFACE_STAT_POLLER=true docker.sevone.
com/sc/collectors/silverpeak:develop >> /var/log/sdwan-silverpeak
/silverpeak_interface_stat_poller.log 2>&1
#Ansible: silverpeak tunnel stat poller
*/5 * * * * docker run --rm --net=host --env-file /opt/sdwan-silverpeak
/collector-poller-settings.env -e ENABLE_TUNNEL_STAT_POLLER=true docker.sevone.com/
sc/collectors/silverpeak:develop >> /var/log/sdwan-silverpeak
/silverpeak_tunnel_stat_poller.log 2>&1
#Ansible: silverpeak metadata poller
*/30 * * * * docker run --rm --net=host --env-file /opt/sdwan-silverpeak
/collector-poller-settings.env -e ENABLE_METADATA_POLLER=true -e
ENABLE_APPLY_RULES_POLLER=true docker.sevone.com/sc/collectors/silverpeak:develop
>> /var/log/sdwan-silverpeak/silverpeak_metadata_poller_develop.log 2>&1
4.1 Verify that Data Appears in SevOne NMS
Once the collector has been running for 15 to 20 minutes, data should appear in SevOne NMS. Perform the
following steps to verify this.
Log into SevOne NMS.
SD-WAN 2.2 Silver Peak Collector Installation Guide
18 of 20
2.
3.
4.
From the navigation bar, go to , select from .Administration Object Types Monitoring Configuration
From the navigation bar, go to , select and then select .Devices Grouping, Device Groups
From the navigation bar, go to , select and then select .Devices Grouping, Object Groups
SD-WAN 2.2 Silver Peak Collector Installation Guide
19 of 20
5.
1.
From the navigation bar, go to and select . Click on to Administration Metadata Schema Add Namespace
check metadata creation.
5 Useful Commands
Execute the following command to check the log.
Tail log
$ tail -f /var/log/sdwan-silverpeak/silverpeak_collector.log
$ tail -f /var/log/sdwan-silverpeak/silverpeak_device_summary_poller.log
$ tail -f /var/log/sdwan-silverpeak/silverpeak_interface_poller.log
$ tail -f /var/log/sdwan-silverpeak/silverpeak_tunnel_poller.log
$ tail -f /var/log/sdwan-silverpeak/silverpeak_interface_stat_poller.log
$ tail -f /var/log/sdwan-silverpeak/silverpeak_tunnel_stat_poller.log
$ tail -f /var/log/sdwan-silverpeak/silverpeak_metadata_poller.log
SD-WAN 2.2 Silver Peak Collector Installation Guide
20 of 20
2.
3.
Execute the following commands to cleanup old containers, SD-WAN 2.2 Silver Peak Collector image, and
any other images.
$ docker rmi docker.sevone.com/sc/collectors/silverpeak:<collector-release-tag>
$ docker images -qf "dangling=true" -q | xargs -r docker rmi
$ docker volume ls -qf dangling=true | xargs -r docker volume rm
To stop the collector, manually remove the cronjobs.
$ crontab -e