sd-301 - united states army

24
70'-0" 1'-0" 18'-0"± SOL I CI T AT I ON NO. : DESI GNED BY: DESCRI PT I ON 1 A M ARK SI ZE: SUBM I TTED BY: DATE CONT RACT NO. : CHECKED BY: DRAW N BY: I SSUE DATE: B C D E F G 2 3 4 5 6 7 8 9 10 SHEET ID DS: AEC_Screen.dscript PD: AEC_pdf.pltcfg 12:54:24 PM 2/12/2019 ...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\TYPICAL CROSS SECTION DEMOLITION ® of Engineers US Army Corps U. S. ARM Y CORPS OF ENGI NEERS PROJ ECT I D: F I LE NAM E: CHI CAGO, I LL I NOI S 60604 231 S. L ASALLE ST , SUI TE 1500 CHI CAGO DI ST RI CT 114419 KPC 114419_ SD- 301 . dgn ANSI D CHI CAGO, I LL I NOI S NORT H PI ER REPAI RS CHI CAGO L OCK KPC F AYE LEFF LER, PE DAVII D F ORCE, SE F L F AYE LEFF LER, PE F L DAVII D F ORCE, SE SD-301 SD-301 DEM O L I T I ON T YP I CAL CRO SS S ECT I ON DEM O L I T I ON T YP I CAL CRO SS S ECT I ON A1 TYPICAL CROSS SECTION - DEMOLITION SCALE: 1/4" = 1' 0 4' 8' 2' X-### X# TOP OF SSP 582.5 TOP OF SSP 582.5 LAKESIDE RIVERSIDE CENTERLINE OF EXISTING WALE EL. 581.25± (VARIES & VERIFY) EL. 546.7 EL. 531.7 (EVERY THIRD PILE) BOTTOM OF EXISTING SSP EL. 534.75 2 - C9X20 WALE NEW PZ27 SHEET PILE ANCHOR WALL LONG EVERY 3RD PILE 50' PILE 35' LONG. EXISTING SHEET WALL CAP CONCRETE EXISTING 12" DUCK BANK TO REMAIN EXISTING UTILITY STRUCTURE EXISTING TUNNEL EXISTING HANDRAIL DWGS) 2"-3" STONE (SEE REF. SLAB 12"-15' THICK OVER EXISTING CONCRETE EXISTING MZ-38 SSP WALL, WALE AND ANCHORS TO REMAIN BACKFILL (SEE CIVIL SHEETS) TOE STONE SEE CIVIL SHEETS 1 2.5 TO INSTALL NEW SLAB WALLS ONLY AS REQUIRED REMOVE TUNNEL SLABS AND TOP OF STONE 568.0 (MIN.) 1 2 EL. 534.5

Upload: others

Post on 25-Jun-2022

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SD-301 - United States Army

70'-0"

1'-0"

18'-0"±

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg12:54:24 PM 2/12/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\TYPICAL CROSS SECTION DEMOLITION

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

P

ROJE

CT I

D:

FIL

E N

AM

E:

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

114419

KP

C

114419_S

D-3

01.d

gn

AN

SI

D

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

K

PC

FA

YE L

EFF

LE

R, P

E

DA

VII

D F

OR

CE, S

E

FL

FA

YE L

EFF

LE

R, P

E

FL

DA

VII

D F

OR

CE, S

E

SD-301SD-301

DE

MO

LITIO

N

TY

PIC

AL C

RO

SS S

EC

TIO

N

DE

MO

LITIO

N

TY

PIC

AL C

RO

SS S

EC

TIO

N

A1TYPICAL CROSS SECTION - DEMOLITIONSCALE: 1/4" = 1' 0 4' 8'2'X-###

X#

TOP OF SSP 582.5 TOP OF SSP 582.5

LAKESIDERIVERSIDE

CENTERLINE OF EXISTING WALE EL. 581.25±

(VARIES & VERIFY)

EL. 546.7

EL. 531.7 (EVERY THIRD PILE)

BOTTOM OF EXISTING SSP EL. 534.75

2 - C9X20 WALE

NEW PZ27 SHEET PILE ANCHOR WALL

LONG

EVERY 3RD PILE 50'

PILE 35' LONG.

EXISTING SHEET

WALL CAP

CONCRETE

EXISTING 12"

DUCK BANK TO REMAIN

EXISTING UTILITY

STRUCTUREEXISTING TUNNEL

EXISTING HANDRAIL

DWGS) 2"-3" STONE (SEE REF.

SLAB 12"-15' THICK OVEREXISTING CONCRETE

EXISTING MZ-38 SSP WALL, WALE AND ANCHORS TO REMAIN

BACKFILL

(SEE CIVIL

SHEETS)

TOE STONE SEE CIVIL SHEETS

1

2.5

TO INSTALL NEW SLAB

WALLS ONLY AS REQUIRED

REMOVE TUNNEL SLABS AND

TOP OF STONE 568.0 (MIN.)

1

2

EL. 534.5

Page 2: SD-301 - United States Army

70'-0"

1'-0"

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

TOP OF SSP EL. 582.5

EL. 588.0

BOTTOM OF EXISTING SSP EL. 534.75

CENTERLINE OF EXISTING WALE EL. 581.25±

(VARIES & VERIFY)

EL. 567.5 OR EL. 562.5 (SEE PLAN)

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg12:54:30 PM 2/12/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\PARKING LOT CROSS SECTION DEMOLITION

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

P

ROJE

CT I

D:

FIL

E N

AM

E:

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

114419

KP

C

114419_S

D-3

02.d

gn

AN

SI

D

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

K

PC

FA

YE L

EFF

LE

R, P

E

DA

VII

D F

OR

CE, S

E

FL

FA

YE L

EFF

LE

R, P

E

FL

DA

VII

D F

OR

CE, S

E

SD-302SD-302

A1SCALE: 1/4" = 1' 0 4' 8'2'X-###

X#

DE

MO

LITIO

N

PA

RKIN

G L

OT C

RO

SS S

EC

TIO

N

DE

MO

LITIO

N

PA

RKIN

G L

OT C

RO

SS S

EC

TIO

N

PARKING LOT CROSS SECTION - DEMOLITION

FE

B 2

019

PARKING SURFACE

EXISTING SSP ANCHORS AND WALE TO REMAIN

EXISTING SSP WALL TO REMAIN

(SEE PLAN)

LINE BY CONTRACTOR

APPROXIMATE EXCAVATION

BACKFILL (SEE CIVIL SHEETS)

UNDISTURBED EARTH

TOP OF SSP 582.5

STRUCTURE

EXISTING TUNNEL

WALL

ANCHOR

SHEET PILE

NEW PZ27

RIVERSIDE LAKESIDE

1. ANY SOIL EXCAVATED IN THE PARKING LOT FOR

INSTALLATION OF THE TIE RODS OR THE NEW SSP

ANCHOR WALL SHALL BE DISPOSED OF OFFSITE BY IAW

SPECIFICATIONS. THE TOP 12" OF THE PARKING SURFACE

SHALL BE REPLACED IN KIND.

TO INSTALL NEW SLAB

WALLS ONLY AS REQUIRED

REMOVE TUNNEL SLABS AND

INSTALL NEW SLAB

AS REQUIRED TO

EXISTING SLAB ONLY

REMOVE 4"-6" OF

DUCK BANK TO REMAIN

EXISTING UTILITY

NOTES:

Page 3: SD-301 - United States Army

2'-0"

10"

1'-0"

18'-0"±

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg12:54:37 PM 2/12/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\EAST END DEMOLITION

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

P

ROJE

CT I

D:

FIL

E N

AM

E:

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

F

AY

E L

EFF

LE

R, P

E

SD-303

114419

KP

C

DA

VID F

OR

CE, S

E

FL

114419_S

D-3

03.d

gn

AN

SI

D

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

FA

YE L

EFF

LE

R, P

E

SD-303

KP

C

FL

DA

VID F

OR

CE, S

E

B1SCALE: 3/8" = 1' 4'0 2' 8'X-###

X# SECTION AT NORTH BASIN WALL

EA

ST E

ND D

EM

OLITIO

NE

AS

T E

ND D

EM

OLITIO

N

SAWCUT 4" MIN. ALL AROUND

BEAM POCKET

TOP OF SSP 582.5

LAKESIDERIVERSIDE

EL. 546.7

EL. 531.7 (EVERY THIRD PILE)

NEW PZ27 SHEET PILE ANCHOR WALL

LONG

EVERY 3RD PILE 50'

PILE 35' LONG.

EXISTING SHEET

WALL CAP

CONCRETE

EXISTING 12"

DUCK BANK TO REMAIN

EXISTING UTILITY

STRUCTUREEXISTING TUNNEL

BACKFILL

(SEE CIVIL

SHEETS)

TOE STONE SEE CIVIL SHEETS

1

2.5

TOP OF STONE 577.0 (MIN.)

1

2

SLAB

INSTALL NEW CONCRETE

VAULT AS REQUIRED TO

EXISTING TRANSFORMER

REMOVE TOP PORTION OF

STRUCTURE

REF DWGS.) NORTH BASIN

BEAM POCKETS (SEE C-19,

AND DAMAGE TO EXISTING

PREVENT UNDERMINING

TO 10" DEPTH THIS SIDE TO

LIMIT CONCRETE REMOVAL

REMOVE TUNNEL SLAB, MANHOLES, TEC.

BASIN WALL NORTH

EXISTING

2 - C9X20 WALE

EL. 534.5

Page 4: SD-301 - United States Army

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg8:49:26 AM 1/28/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\114419_S-100.dgn

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

P

ROJE

CT I

D:

FIL

E N

AM

E:

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

S-100

114419

114419_S-1

00.d

gn

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

S-100

FA

YE L

EFF

LE

R, P

E

KP

C

DA

VID F

OR

CE, S

E

FL

AN

SI

D

FA

YE L

EFF

LE

R, P

E

KP

C

FL

DA

VID F

OR

CE, S

E

MA

TC

HLIN

E T

O S-1

01

0 8'4' 16'SCALE: 1/8" = 1'C1

ST

RU

CT

UR

AL P

LA

NS

TR

UC

TU

RA

L P

LA

N

TIE R

OD A

ND A

NC

HO

R W

ALL

TIE R

OD A

ND A

NC

HO

R W

ALL

STRUCTURAL PLAN - TIE ROD AND ANCHOR WALL

1S-302

Page 5: SD-301 - United States Army

CUT SHEETPILE AND WALE AS REQUIRED TO MAINTAIN CLEARANCE.3" MIN - 6" MAX TO CLEAR EXISTING BURIED BULKHEAD.

WITH RIVERSIDE WALL

ALIGN "BELLY-OUTS" OF ANCHOR WALL

DRIVE SHEET PILE ANCHOR WALL TO

SEE S-502 FOR SHEET PILE ANCHOR DETAILS

WITH RIVERSIDE WALL

ALIGN "BELLY-OUTS" OF ANCHOR WALL

DRIVE SHEET PILE ANCHOR WALL TO

EXISTING BURIED BULKHEAD

ADJUST TIE RODS LOCATIONS TO CLEAR EXISTING SHEET PILE WEBS (TYP)

BULKHEAD

BURIED

EXISTING

TO CLEAR

TIE ROD

LOCATE

EDGE OF CONCRETE TUNNEL

EDGE OF CONCRETE TUNNEL

TO INSTALL TIE RODS.

AND REPLACE MANHOLES IN KIND

MANHOLES. ALTERNATELY, REMOVE

OR SETTLEMENT OF EXISTING

METHODS TO PREVENT UNDERMINING

UNDER EXISTING MANHOLES USING

INSTALL NEW TIE RODS AND SLEEVES

SSP T/P EL. 562.5

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

S-101

AN

SI

D

PR

OJE

CT I

D:

FIL

E N

AM

E:

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg8:54:18 AM 1/28/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\114419_S-101.dgn

KP

C

FL

114419

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

114419_S-1

01.d

gn

C1SCALE: 1/8" = 1' 0 8'4' 16'

MA

TC

HLIN

E T

O S-1

02

FA

YE L

EFF

LE

R, P

E

DA

VII

D F

OR

CE, S

E

MA

TC

HLIN

E T

O S-1

00

ST

RU

CT

UR

AL P

LA

N

TIE R

OD A

ND A

NC

HO

R W

ALL

STRUCTURAL PLAN - TIE ROD AND ANCHOR WALL

1S-301A

S-50430'-0"

SSP T/P EL. 567.5

1S-302 1

S-301

Page 6: SD-301 - United States Army

RIPRAP

EDGE OF CONCRETE TUNNEL

EDGE OF CONCRETE TUNNEL

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

S-102

AN

SI

D

PR

OJE

CT I

D:

FIL

E N

AM

E:

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg8:56:49 AM 1/28/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\114419_S-102.dgn

KP

C

FL

114419

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

114419_S-1

02.d

gn

C1SCALE: 1/8" = 1' 0 8'4' 16'

MA

TC

HLIN

E T

O S-1

03

MA

TC

HLIN

E T

O S-1

01

DA

VII

D F

OR

CE, S

E

FA

YE L

EFF

LE

R, P

E

ST

RU

CT

UR

AL P

LA

N

TIE R

OD A

ND A

NC

HO

R W

ALL

STRUCTURAL PLAN - TIE ROD AND ANCHOR WALL

1S-301

Page 7: SD-301 - United States Army

30'-0"

10'-6"

31'-6"

EDGE OF CONCRETE TUNNEL

EDGE OF CONCRETE TUNNEL

INSTALL TIE RODS THRU EXISTING TUNNEL VAULT CONCRETE

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

S-103

AN

SI

D

PR

OJE

CT I

D:

FIL

E N

AM

E:

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg9:03:33 AM 1/28/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\114419_S-103.dgn

KP

C

FL

114419

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

114419_S-1

03.d

gn

B1SCALE: 1/8" = 1' 0 8'4' 16'

MA

TC

HLIN

E T

O S-1

02

DA

VII

D F

OR

CE, S

E

FA

YE L

EFF

LE

R, P

ETIE R

OD A

ND A

NC

HO

R W

ALL

ST

RU

CT

UR

AL P

LA

N

STRUCTURAL PLAN - TIE ROD AND ANCHOR WALL

1S-301

BS-504

Page 8: SD-301 - United States Army

70'-0"

1'-0"

2"

18'-0"±

2'-0"8'-0"±2'-0"

6'-0"±

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg12:55:00 PM 2/12/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\TYPICAL CROSS SECTION

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

P

ROJE

CT I

D:

FIL

E N

AM

E:

114419_S-3

01.d

gn

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

114419

114419

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

TY

PIC

AL C

RO

SS S

EC

TIO

N

S-301

KP

C

FL

TY

PIC

AL C

RO

SS S

EC

TIO

N

S-301

KP

C

FL

AN

SI

D

A1TYPICAL CROSS SECTIONSCALE: 1/4" = 1'

N

0 4' 8'2'X-###

X#

FA

YE L

EFF

LE

R, P

EF

AY

E L

EFF

LE

R, P

E

DA

VII

D F

OR

CE, S

ED

AVII

D F

OR

CE, S

EF

EB 2

019

TOP OF SSP 582.5 TOP OF SSP 582.5

LAKESIDE

RIVERSIDE

GENERAL NOTES:

CENTERLINE OF EXISTING WALE EL. 581.25±

(VARIES & VERIFY)

EL. 546.7

EL. 531.7 (EVERY THIRD PILE)

BOTTOM OF EXISTING SSP EL. 534.75

2 - C9X20 WALE

PIPE SLEEVE

SCHEDULE 80 PVC

5.563" O.D. ASTM D1785

ROD IN HOLE

SLEEVE. CENTER TIE

NEW TIE ROD AND

PILE WALL TO INSTALL

THRU EXISTING SHEET

AND 5.625"Ø HOLE

EXISTING CONCRETE

NEW 6"Ø HOLE THRU

LONG

EVERY 3RD PILE 50'

PILE 35' LONG.

EXISTING SHEET

WALL CAP

CONCRETE

EXISTING 12"

DUCK BANK TO REMAIN

EXISTING UTILITY

STRUCTUREEXISTING TUNNEL EXISTING HANDRAIL

EXISTING MZ-38 SSP WALL, WALE AND ANCHORS TO REMAIN

RODS IN PIPE SLEEVES.

TIE RODS U.N.O. CENTER TIE

BETWEEN EXISTING RIVERSIDE

AT 6'-0" O.C. CENTERED

NEW #14 ALL THREAD TIE RODS

NEW 6"Ø HOLE TO INSTALL/JACK PIPE SLEEVE

BACKFILL

(SEE CIVIL

SHEETS)

1

2.5

EL. 534.5

CONCRETE WALLS

6" HOLE THRU EXISTING

CENTER NEW TIE RODS IN NEW

DWGS) HAUNCHES (SEE REF.

CONCRETE SLAB SLAB 12"-15" AND

EXISTING CONCRETE

NEW 6"Ø HOLE THRU TUNNEL WALL

(MIN. 24" LONG)(TYP.)

WATERTIGHT FLEXIBLE PLUG

CHEMICAL GROUT TO FORM

WITH POLYURETHANE

CENTER TIE ROD AND PACK

TOP OF TOE STONE EL. 568 (MIN.)

TOE STONE SEE CIVIL SHEETS

1

2

EXISTING TIE RODS TO REMAIN IN PLACE.

SAWCUT WALE, EXISTING TIE RODS, OR SSP.

EXERCISE CARE TO NOT DAMAGE OR

NEW TIE ROD TO EXISTING C9X20 WALE.

REMOVE EXISTING CONCRETE TO CONNECT

WALLANCHOR SHEET PILE NEW PZ27

1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS

PRIOR TO START OF WORK INCLUDING ALL

DIMENSIONS SHOWN IN REFERENCE DRAWINGS.

2. CENTERLINE ELEVATION OF EXISTING WALE SHALL

BE VERIFIED PRIOR TO DRILLING HOLES THRU

EXISTING TUNNEL CROSS SECTION AND

INSTALLATION OF NEW SHEET PILE ANCHOR WALL

AND WALE. ELEVATION OF EXISTING WALE MAY

VARY ALONG THE LENGTH OF THE EXISTING SHEET

PILE WALL. NEW WALE ON NEW ANCHOR WALL

SHALL BE ADJUSTED TO MATCH ELEVATION OF

EXISTING WALE ON EXISTING RIVERSIDE SHEET PILE

WALL. CENTERLINES OF HOLES TO BE DRILLED

THRU THE EXISTING TUNNEL WALLS SHALL MATCH

THE CENTERLINE OF THE EXISTING WALE.

3. CONTRACTOR SHALL TAKE ALL NECESSARY

PRECAUTIONS TO PROTECT INTEGRITY OF EXISTING

STRUCTURES TO REMAIN.

4. CONTRACTOR SHALL CLEAR DRIVELINE AS

REQUIRED TO INSTALL NEW LAKESIDE SHEET PILE

ANCHOR WALL. EXISTING TOE STONE MAY BE

REQUIRED TO BE CLEARED BELOW THE LAKEBED

ELEVATION. CONTRACTOR SHALL LIMIT LENGTH OF

DRIVELINE CLEARING TO MAINTAIN THE INTEGRITY

OF THE EXISTING SHEET PILE AND TIMBER CRIB.

CONTRACTOR SHALL PROVIDE ANY TEMPORARY

BRACING NECESSARY TO PROTECT AND PREVENT

ANY MOVEMENT OF THE EXISTING LAKESIDE WALL

CAP, SHEET PILE, AND EXISTING UTILITY DUCT BANK

DURING DRIVELINE CLEARING AND ANCHOR WALL

INSTALLATION.

5. NEW TIE RODS ARE REQUIRED TO BE INSTALLED

THROUGH EXISTING CONCRETE TUNNEL WALLS,

EXISTING LAKESIDE WALL CAP/SHEET PILE, AND

THROUGH EXISTING SOIL FILL. CONTRACTOR SHALL

MINIMIZE EXCAVATION AROUND EXISTING UTILITY

DUCT BANK AND MANHOLES TO PREVENT

SETTLEMENT OF THE DUCT BANK OR MANHOLES.

TIE RODS SHALL NOT BE JACKED THRU SOIL TO

PREVENT DAMAGE TO COATING. PIPE SLEEVE ON

LAKESIDE IS REQUIRED.

6. THE CONTRACTOR IS RESPONSIBLE FOR

SEQUENCING BACKFILL PLACEMENT BEHIND THE

NEW SHEET PILE ANCHOR WALL TO PREVENT

DAMAGE TO THE SHEET PILE ANCHOR WALL, TIE

RODS, OR WALE SYSTEM DURING ANY TEMPORARY

LOADING CONDITION. THE TOE BERM SHALL BE

PLACED AS THE BACKFILL BEHIND THE NEW

ANCHOR WALL IS PLACED TO PREVENT DAMAGE TO

OR OVERSTRESSING THE SHEET PILE WALL, WALES

OR TIE RODS. NO TOE STONE SHALL BE PLACED

ABOVE THE ELEVATION OF THE TIE RODS AND CARE

SHALL BE TAKEN DURING TOE STONE PLACEMENT

TO PREVENT DAMAGE TO THE TIE RODS OR THE TIE

ROD PROTECTIVE COATING.

Page 9: SD-301 - United States Army

70'-0"

1'-0"

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

TOP OF SSP EL. 582.5

EL. 588.0

BOTTOM OF EXISTING SSP EL. 534.75

CENTERLINE OF EXISTING WALE EL. 581.25±

(VARIES & VERIFY)

EL. 567.5 OR EL. 562.5

(SEE PLAN)

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg12:55:07 PM 2/12/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\PARKING LOT CROSS SECTION

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

P

ROJE

CT I

D:

FIL

E N

AM

E:

114419_S-3

02.d

gn

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

114419

114419

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

PA

RKIN

G L

OT C

RO

SS S

EC

TIO

N

S-302

KP

C

FL

PA

RKIN

G L

OT C

RO

SS S

EC

TIO

N

S-302

KP

C

FL

AN

SI

D

A1SCALE: 1/4" = 1' 0 4' 8'2'X-###

X# PARKING LOT CROSS SECTION

FA

YE L

EFF

LE

R, P

EF

AY

E L

EFF

LE

R, P

E

DA

VII

D F

OR

CE, S

ED

AVII

D F

OR

CE, S

E

FE

B 2

019

PARKING SURFACE

EXISTING SSP ANCHORS AND WALE TO REMAIN

EXISTING SSP WALL TO REMAIN

(SEE PLAN)

BOTTOM OF PVC

SIDE ONLY. LOCATE TIE ROD AT

OVER TIE ROD ON PARKING LOT

SCHEDULE 80 PVC PIPE SLEEVE

PROVIDE 5.563"O.D. ASTM D1785

U.N.O.(SEE PLAN)

TIE RODS @ 6'-0" O.C.

NEW #14 ALL THREAD

LINE BY CONTRACTOR

APPROXIMATE EXCAVATION

BACKFILL (SEE CIVIL SHEETS)

UNDISTURBED EARTH

STRUCTURE

EXISTING TUNNEL

TOP OF SSP 582.5

WALL

ANCHOR

SHEET PILE

NEW PZ27

RIVERSIDE LAKESIDE

RODS IN PIPE SLEEVES.

TIE RODS U.N.O. CENTER TIE

BETWEEN EXISTING RIVERSIDE

AT 6'-0" O.C. CENTERED

NEW #14 ALL THREAD TIE RODS

NEW 6"Ø HOLE TO INSTALL/JACK PIPE SLEEVE

NEW 6"Ø HOLE THRU TUNNEL WALL

CONCRETE WALLS

6" HOLE THRU EXISTING

CENTER NEW TIE RODS IN NEW

(MIN. 24" LONG)(TYP.)

WATERTIGHT FLEXIBLE PLUG

CHEMICAL GROUT TO FORM

WITH POLYURETHANE

CENTER TIE ROD AND PACK

EXISTING TIE RODS TO REMAIN IN PLACE.

SAWCUT WALE, EXISTING TIE RODS, OR SSP.

EXERCISE CARE TO NOT DAMAGE OR

NEW TIE ROD TO EXISTING C9X20 WALE.

REMOVE EXISTING CONCRETE TO CONNECT

Page 10: SD-301 - United States Army

2 1/2 "± FIE

LD V

ERIF

Y

2" CL.

24" (MIN)

6"Ø D

RIL

LE

D

24" (MIN)

3"

3"

2" CL.

(VARIES & VERIFY)

CENTERLINE OF EXISTING WALE EL. 581.25±

2 - C9X20 WALE

WALLANCHOR SHEET PILE NEW PZ27

C OF EXISTING WALEL

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

CENTERLINE OF EXISTING WALE EL. 581.25

TOP OF SSP 582.5

PRIO

R T

O O

RD

ERIN

G

TIE R

OD

S

EXISTING 2-C9X20 WALE

EXISTING SSP

NEW 7"X7"X1" PLATE

NEW TIE ROD AND NUT

EXISTING REINFORCED CONCRETE TUNNEL WALL

TOP OF SSP 582.5

EXISTING REINFORCED CONCRETE TUNNEL WALL

LC TIE ROD & EXISTING WALE

C ANCHOR WALL WALE TO MATCH C OF EXISTING WALEL L

AROUND TIE ROD

PVC PIPE SLEEVE CENTERED

REMOVE EXISTING REINFORCED CONCRETE SLAB (SEE REF. DWGS)

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

S-501

AN

SI

D

PR

OJE

CT I

D:

FIL

E N

AM

E:

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg12:55:14 PM 2/12/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\TIE ROD INSTALLATION DETAILS

TIE R

OD I

NS

TA

LL

ATIO

N D

ETIL

S

KP

C

FL

114419

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

114419_S-5

01.d

gn

D1SCALE: 3/4" = 1' 2'0 1' 4'S-501

1

D7TIE ROD INSTALLATION DETAILSSCALE: 3/4" = 1' 2'0 1' 4'S-501

2

A1SCALE: 3/4" = 1' 2'0 1' 4'S-501

3 TIE ROD CONNECTION AT SSP ANCHOR WALL

TIE ROD CONNECTION - RIVERSIDE

FA

YE L

EFF

LE

R, P

E

DA

VII

D F

OR

CE, S

E

HO

LE T

HR

U

EXIS

TIN

G

CO

NC

RE

TE

POLYURETHANE GROUTPOLYURETHANE GROUT

TOP OF SSP 582.5

TOP OF SSP 582.5

NEW PVC PIPE SLEEVE

MANUFACTURER

NUTS AND NEW WASHERS PER

NEW ALL THREAD TIE ROD AND

NEW SSP ANCHOR WALL

NEW 7"X7"X1" PLATE

NEW 2-C9X20 WALE

(BACKFILL NOT SHOWN)

(BACKFILL NOT SHOWN)

1

2.5

Page 11: SD-301 - United States Army

2 1/2 "

3" (TYP.)

4 1/2 "

1 1/4 "

1 1/4 "

1'-9"

6'-0" O.C.

6"

12" (TYP.)

9"

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

LOCATIONS TO MATCH EXISTING LAKESIDE SSP WALL

TYP5/16

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

S-502

AN

SI

D

PR

OJE

CT I

D:

FIL

E N

AM

E:

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg12:55:22 PM 2/12/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\SHEET PILE ANCHOR WALL DETAILS

SH

EE

T PIL

E A

NC

HO

R W

ALL D

ET

AIL

S

KP

C

FL

114419

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

114419_S-5

02.d

gn

E2SCALE: 1 1/2" = 1' 1' 2'0 6"

D7

SCALE: 1 1/2" = 1' 1' 2'0 6"

A1

SCALE: 1 1/2" = 1' 1' 2'0 6" A7

SCALE: 1 1/2" = 1' 1' 2'0 6"A4

SCALE: 1 1/2" = 1' 1' 2'0 6"

D1

SCALE: 1 1/2" = 1' 1' 2'0 6"

TIE ROD CONNECTION DETAIL

SSP/WALE TENSION BOLTWALE SPACER DETAILWALE SPLICE DETAIL

WALE SPLICE DETAIL

NEW SSP ANCHOR WALL PLAN

FA

YE L

EFF

LE

R, P

E

DA

VII

D F

OR

CE, S

E

3"TYP

5/16

TYP5/16

TYP5/16

TYP5/16

TIE ROD NUT & WASHER PER MFR'S REQUIREMENTS

#14 (1.75" NOM. Ø) ASTM A-615 GR 75 ALL THREAD TIE ROD (TYP.)

(2) - C9X20 WALES

SPLICE PLATES

1'-8"X7"X5/8" TOP & BOTTOM

NUT AND WASHER, TYP.

1"Ø A325 BOLTS (TYP.)

1"Ø A325 BOLTS (TYP.)

(TYP.)

SPACER PLATE

9"X2 1/2"X3/8"

7"x7"x1" PLATE

Z-SHAPE SSP SHEET PILE

3"X3"X1/2" PLATE WASHER

1"Ø A325 BOLT (2/ CONNECTION) (2) - CX9X20 WALES

7"X12"X1" PLATE (TYP.)

INTERLOCK SPACING (TYP.)

WALL SPACER @ 3'-0" O.C. TO MATCH

3"X3"X1/2" THICK PLATE (TYP.)

7"X7"X1" PLATE

NUT AND WASHER, TYP.

NOTE: LOCATE SPLICES CENTERED BETWEEN TIE RODS. STAGGER TOP AND BOTTOM SPLICES

WALL (TYP.)

OTHER INTERLOCK ALONG

CONNECTION) AT EVERY

1"Ø A325 BOLTS (2 PER

2" DIA. DRAIN HOLE IN TOP WALE @ 6'-0" (TYP.)

TIE RODS (TYP.)

PROVIDE BEVELED WASHERS FOR ALL ANGLED

TIE ROD, NUTS & WASHERS PER MANUFACTURER

Page 12: SD-301 - United States Army

2" CL

4" CL

12"±

NEW TIE ROD TO MATCH

EXISTING WALE ON

RIVERSIDE SHEET PILE WALLLC

INTERFERENCE

PREVENT

LOCATIONS TO

TUNNEL HOLE

ROD LOCATIONS AND

AND ADJUST NEW TIE

TIE ROD LOCATIONS

SURVEY EXISTING

DWGS)

REMAIN (SEE REF.

8'-2 1/8" C/C TO

EXISTING TIE RODS AT

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

4" LONG STEEL PIPE 5.563" O.D.

LAKESIDE FACE OF SSP

5/16

GROUT

POLYURETHANE

PACK WITH

NOTE: CONDITION OF EXISTING TIE RODS AND WALE ARE

UNKNOWN AND SHOULD BE ASSUMED NOT PRESENT WHEN

DETERMINING TEMPORARY SHORING MEASURES FOR EXISTING

SHEET PILE WALL.

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

S-503

P

ROJE

CT I

D:

FIL

E N

AM

E:

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg12:55:29 PM 2/12/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\TIE ROD DETAILS

TIE R

OD D

ET

AIL

S

KP

C

FL

114419

AN

SI

D

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

114419_S-5

03.d

gn

D7

SCALE: 3" = 1'

SHEET PILE SLEEVE6"0 3" 1'S-503

3

D1TIE ROD AT EXISTING SHEET PILE CUT OFF WALLSCALE: 1" = 1' 0 1' 2'6"S-301

1

FA

YE L

EFF

LE

R, P

E

DA

VII

D F

OR

CE, S

E

EXISTING CONCRETE

EXISTING TIMBERS

EL. 583.2±

EL. 580.7±

NEW TIE ROD

NEW PVC PIPE SLEEVE

EXISTING MP-II5 SHEET PILE

TOP OF SSP EL. 581.7±

C6 WALE

WALE

PILE. DO NOT CUT EXISTING

HOLE THRU EXISTING SHEET

CONCRETE WALL AND 5.625"Ø

DRILL/CUT 6"Ø HOLE THRU

3S-503

Page 13: SD-301 - United States Army

4'-6"

3" (MAX)1" (MIN)

31'-6"

4'-6"

30'-0"

10'-6"

30'-0"

31'-6"

9 3/4 "9 3/4 "

1 1/4 "1 1/4 "

4 5/16 "1 1/4 "9 3/4 "9 3/4 "1 1/4 "

1 1/4 " (TYP.)

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

THRU PLATE

TO PASS TIE ROD

LONG SLOTTED HOLE

PROVIDE 2-1/2"X6"

C9

X20

C9X20

WALL/BULKHEAD

CONCRETE DOCK

EXISTING

PROVIDE "SOCKET" FOR FUTURE CONNECTION

RE

TU

RN W

ALL

C9X20 B

RACE

DOCK WALL

GAP TO EXISTING

MAINTAIN 3" MAX

REQUIRED TO

MANUFACTURER AS

CORNER PER PILE

90° OR BENT

WITH FABRICXATED

PZ27 SHEET PILE

PROVIDE PART OF

TIE RODS

INSTALLATION OF NEW

OUTS" FOR

SHEET PILE "BELLY

EXISTING RIVERSIDE

ANCHOR WALL TO MATCH

OF NEW LAKESIDE

LOCATE "BELLY OUTS"

OF TIE ROD

(TYP.) BOTH SIDES

MANUFACTURER

WASHERS PER

PROVIDE BEVELED

EXCEPT FOR 2' ON EACH END TO BE 3" O.C. (TYP.)

CONNECTIONS USE 7/8" BOLTS @ 6" O.C.

T-PILE PER MANUFACTURER. FOR BOLTED

WELD 90° INTERLOCK FULL HEIGHT OR PROVIDE

7"x 6"x 1" PLATE (TYP.)

LAST TIE ROD

2 - C9X20 WALE

2 - C9X20 WALE

2 - C9X

20 WALE

END TO BE 3" O.C. (TYP.)

EXCEPT FOR 2' ON EACH

USE 7/8" BOLTS @ 6" O.C.

BOLTED CONNECTIONS

PER MANUFACTURER. FOR

HEIGHT OR PROVIDE T-PILE

WELD 90° INTERLOCK FULL

WALE TENSION BOLTS

FIT BETWEEN SHEET PILE

CUT CORNER BRACING TO

CONNECTION

3/4" BOLTS - 6 PER 2 - C9X20

2 - C9X

20

PLATE - 7 13/16"X22"X3/4"

5/16TYP

(NOTE: SIMILAR FOR WEST END BRACE)

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

S-504

AN

SI

D

PR

OJE

CT I

D:

FIL

E N

AM

E:

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg12:55:38 PM 2/12/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\ANCHOR WALL DETAILS

AN

CH

OR W

ALL D

ET

AIL

S

KP

C

FL

114419

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

114419_S-5

04.d

gn

E1SCALE: 3/4" = 1' 2'0 1' 4'S-101

F5

A1SCALE: 3/4" = 1' 2'0 1' 4'S-103

F7

E7

SCALE: 1 1/2" = 1' 1' 2'0 6"S-504

D9

E8

SCALE: 1 1/2" = 1' 1' 2'0 6"S-504

F6

FA

YE L

EFF

LE

R, P

E

DA

VII

D F

OR

CE, S

E

DETAIL A - ANCHOR WALL AT WEST END DETAIL C - BRACING SECTION 1

DETAIL B - ANCHOR WALL AT EAST END

1S-504

CS-504

Page 14: SD-301 - United States Army

25'-0" (M

IN.)

4'-0"

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg2:23:39 PM 2/12/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\STRUCTURAL PLAN NEW CONCRETE

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

P

ROJE

CT I

D:

FIL

E N

AM

E:

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

FA

YE L

EFF

LE

R, P

E114419

KP

C

DA

VII

D F

OR

CE, S

E

FL

114419_S

S-1

00.d

gn

AN

SI

D

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

FA

YE L

EFF

LE

R, P

E

KP

C

FL

DA

VII

D F

OR

CE, S

E

0 8'4' 16'B2SCALE: 1/8" = 1'

MA

TC

HLIN

E T

O S

S-1

01

ST

RU

CT

UR

AL P

LA

NS

TR

UC

TU

RA

L P

LA

N

SS-100SS-100

STRUCTURAL PLAN NEW CONCRETE

NE

W C

ON

CR

ET

EN

EW C

ON

CR

ET

E

FE

B 2

019

ASS-401

NEW RETAINING WALL

NEW GALVANIZED STEEL STAIR W/ HANDRAILS ON EACH SIDE

RETURN NEW HANDRAIL TO MATCH EXISTING

EDGE OF EXISTING TUNNEL

NEW HANDRAIL

OF EXISTING TUNNEL WALL

SLAB TO LAKEWARD FACE

EXTEND EDGE OF NEW

NEW HANDRAIL

NEW CONCRETE SLAB

NEW CONCRETE TUNNEL CLOSURE WALL

Page 15: SD-301 - United States Army

25'-0" (M

IN.)

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg2:24:14 PM 2/12/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\SLAB AND RETAINING WALL LAYOUT

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

P

ROJE

CT I

D:

FIL

E N

AM

E:

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

FA

YE L

EFF

LE

R, P

E114419

KP

C

FL

114419_S

S-1

01.d

gn

AN

SI

D

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

FA

YE L

EFF

LE

R, P

E

KP

C

FL

0 8'4' 16'C1SCALE: 1/8" = 1'

MA

TC

HLIN

E T

O S

S-1

02

DA

VID F

OR

CE, S

ED

AVID F

OR

CE, S

E

MA

TC

HLIN

E T

O S

S-1

00

NOTE 33.

NOTE 22.

NOTE 11.

GENERAL NOTES

ST

RU

CT

UR

AL P

LA

NS

TR

UC

TU

RA

L P

LA

N

NE

W C

ON

CR

ET

EN

EW C

ON

CR

ET

E

SS-101SS-101

STRUCTURAL PLAN NEW CONCRETE

FE

B 2

019

NEW RETAINING WALL

TUNNEL WALL

SLAB TO FACE OF EXISTING

EXTEND EDGE OF NEW

NEW HANDRAIL

NEW HANDRAIL

NEW CONCRETE SLAB

Page 16: SD-301 - United States Army

25'-0" (M

IN.)

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg2:24:44 PM 2/12/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\STRUCTURAL PLAN NEW CONCRETE

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

P

ROJE

CT I

D:

FIL

E N

AM

E:

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

FA

YE L

EFF

LE

R, P

E114419

KP

C

DA

VID F

OR

CE, S

E

FL

114419_S

S-1

02.d

gn

AN

SI

D

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

FA

YE L

EFF

LE

R, P

E

KP

C

FL

DA

VID F

OR

CE, S

E

MA

TC

HLIN

E T

O S

S-1

01

C1SCALE: 1/8" = 1' 0 8'4' 16'

MA

TC

HLIN

E T

O S

S-1

03

ST

RU

CT

UR

AL P

LA

NS

TR

UC

TU

RA

L P

LA

N

NE

W C

ON

CR

ET

EN

EW C

ON

CR

ET

E

SS-102SS-102

STRUCTURAL PLAN NEW CONCRETE

FE

B 2

019

NEW RETAINING WALL

TUNNEL WALL

SLAB TO FACE OF EXISTING

EXTEND EDGE OF NEW

NEW HANDRAIL

NEW HANDRAIL

NEW CONCRETE SLAB

Page 17: SD-301 - United States Army

25'-0" (M

IN.)

4'-0"

18'-0"

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg2:25:15 PM 2/12/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\SLAB AND RETAINING WALL LAYOUT

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

P

ROJE

CT I

D:

FIL

E N

AM

E:

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

FA

YE L

EFF

LE

R, P

E114419

KP

C

DA

VID F

OR

CE, S

E

FL

114419_S

S-1

03.d

gn

AN

SI

D

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

FA

YE L

EFF

LE

R, P

E

KP

C

FL

DA

VID F

OR

CE, S

E

MA

TC

HLIN

E T

O S

S-1

02

B1SCALE: 1/8" = 1' 0 8'4' 16'

ST

RU

CT

UR

AL P

LA

NS

TR

UC

TU

RA

L P

LA

N

NE

W C

ON

CR

ET

EN

EW C

ON

CR

ET

E

SS-103SS-103

STRUCTURAL PLAN NEW CONCRETE

FE

B 2

019

ASS-402

ASS-303

ASS-304

NEW HANDRAILS

HANDRAILS

NEW

NEW HANDRAILS

TUNNEL WALL

SLAB TO FACE OF EXISTING

EXTEND EDGE OF NEW

ASS-401

NEW CONCRETE SLAB

EXISTING HANDRAIL

CONCRETE

AND NEW

INTO EXISTING

12" EMBEDMENT

#5@12" O.C. MIN.

AND SLAB WITH

EXISTING WALL

DOWEL TO

STOOP IN KIND.

CONCRETE

REPLACE

HAND RAIL IN KIND

REMOVE AND REPLACE

EXPANSION JOINT

MINIMUM 12" EMBEDMENT (TYP.)

OUTSIDE FACE OF EXISTING TUNNEL WITH

#5@12" O.C. DOWELS LOCATED 12" FROM

Page 18: SD-301 - United States Army

70'-0"

1'-0"

25'-0" (MIN.)

1'-0"

1'-4"

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

INSID

E F

AC

E O

F S

SP

INSID

E F

AC

E O

F S

SP

1/4" PER FOOT

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg12:56:17 PM 2/12/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\TYPICAL CROSS SECTION NEW

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

P

ROJE

CT I

D:

FIL

E N

AM

E:

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

TY

PIC

AL C

RO

SS S

EC

TIO

N - N

EW

114419

KP

C

114419_S

S-3

01.d

gn

AN

SI

D

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

TY

PIC

AL C

RO

SS S

EC

TIO

N - N

EW

KP

C

FA

YE L

EFF

LE

R, P

E

DA

VID F

OR

CE, P

E

FL

FA

YE L

EFF

LE

R, P

E

FL

DA

VID F

OR

CE, P

E

SS-301SS-301

A1TYPICAL CROSS SECTION - NEWSCALE: 1/4" = 1' 0 4' 8'2'

TOP OF SSP 582.5 TOP OF SSP 582.5

RIVERSIDE

CENTERLINE OF EXISTING WALE EL. 581.25±

(VARIES & VERIFY)

EL. 546.7

EL. 531.7 (EVERY THIRD PILE)

BOTTOM OF EXISTING SSP EL. 534.75

2 - C9X20 WALE

NEW PZ27 SHEET PILE ANCHOR WALL

LONG

EVERY 3RD PILE 50'

PILE 35' LONG.

EXISTING SHEET

WALL CAP

CONCRETE

EXISTING 12"

DUCK BANK TO REMAIN

EXISTING UTILITY

EXISTING MZ-38 SSP WALL, WALE AND ANCHORS TO REMAIN

BACKFILL

(SEE CIVIL

SHEETS)

TOE STONE SEE CIVIL SHEETS

1

2.5

NEW HANDRAIL

EL. 588.5

RODS

EMBEDMENT. AVOID TIE

ROW (TYP.) MIN. 12"

STAGGER WITH ADJACENT

#6 DOWELS AT 24" O.C.

RIVERSIDE FACE

EL. 584.4± AT 25' FROM

LAKESIDE

1

2

BACKFILL

NEW CA-7

NEW CA-7 BACKFILL

WATERSTOP

HYDROPHILIC

1" SQUARE

TOP OF STONE 568.0 (MIN.)

EL. 534.5

WATERSTOP

HYDROPHILIC

1" SQUARE

TOP CONCRETE EL. 583.83

Page 19: SD-301 - United States Army

70'-0"

1'-0"

25'-0" (MIN.)

1'-0"

1'-4"

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

TOP OF SSP EL. 582.5

BOTTOM OF EXISTING SSP EL. 534.75

CENTERLINE OF EXISTING WALE EL. 581.25±

(VARIES & VERIFY)

1/4" PER FOOT

INSID

E F

AC

E O

F S

SP

INSID

E F

AC

E O

F S

SP

EL. 567.5 OR EL. 562.5

(SEE PLAN)

TOP OF SSP EL. 583.83

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg12:56:24 PM 2/12/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\PARKING LOT CROSS SECTION NEW

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

P

ROJE

CT I

D:

FIL

E N

AM

E:

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

PA

RKIN

G L

OT C

RO

SS S

EC

TIO

N - N

EW

114419

KP

C

114419_S

S-3

02.d

gn

AN

SI

D

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

PA

RKIN

G L

OT C

RO

SS S

EC

TIO

N - N

EW

KP

C

FA

YE L

EFF

LE

R, P

E

DA

VII

D F

OR

CE, S

E

FL

FA

YE L

EFF

LE

R, P

E

FL

DA

VII

D F

OR

CE, S

E

SS-302SS-302

A1SCALE: 1/4" = 1' 0 4' 8'2'

PARKING LOT CROSS SECTION - NEW

FE

B 2

019

CA1 BACKFILL

EXISTING SSP WALL TO REMAIN

(SEE PLAN)

LINE BY CONTRACTOR

APPROXIMATE EXCAVATION

UNDISTURBED EARTH

TOP OF SSP 582.5

WALL

ANCHOR

SHEET PILE

NEW PZ27

RIVERSIDE LAKESIDE

GENERAL NOTES:

1. ANY SOIL EXCAVATED IN THE PARKING LOT FOR

INSTALLATION OF THE TIE RODS OR THE NEW SSP

ANCHOR WALL SHALL BE DISPOSED OF OFFSITE BY IAW

SPECIFICATIONS. THE TOP 12" OF THE PARKING SURFACE

SHALL BE REPLACED IN KIND.

DUCK BANK TO REMAIN

EXISTING UTILITY

NEW HANDRAIL

EL. 588.5

RIVERSIDE FACE

EL. 584.4± AT 25' FROM

RODS

EMBEDMENT. AVOID TIE

ROW (TYP.) MIN. 12"

STAGGER WITH ADJACENT

#6 DOWELS AT 24" O.C.

NEW HANDRAIL

WATERSTOP

HYDROPHILIC

1" SQUARE

NEW CA-7 BACKFILL

NEW CA-7 BACKFILL

EXISTING SSP ANCHORS AND WALE TO REMAIN

PARKING SURFACE

WATERSTOP

HYDROPHILIC

1" SQUARE

Page 20: SD-301 - United States Army

70'-0"

1'-0"

18'-0"±

10"

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

UNDERSIDE OF NEW SLAB.AND SLOPE CONCRETE 1 TO 1 TO MEET CENTER HAUNCHES BETWEEN TIE RODS ON EXISTING TUNNEL FOOTING. @ 6'-0" O.C. TO CREATE 12"X12" BEARING PROVIDE FOUR CONCRETE HAUNCHES

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg12:56:31 PM 2/12/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\EAST END CROSS SECTION SHOWING EXISTING SLAB

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

P

ROJE

CT I

D:

FIL

E N

AM

E:

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

FA

YE L

EFF

LE

R, P

ES

HO

WIN

G E

XIS

TIN

G S

LA

B

EA

ST E

ND C

RO

SS S

EC

TIO

N

114419

KP

C

DA

VID F

OR

CE, S

E

FL

114419_S

S-3

03.d

gn

AN

SI

D

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

FA

YE L

EFF

LE

R, P

ES

HO

WIN

G E

XIS

TIN

G S

LA

B

EA

ST E

ND C

RO

SS S

EC

TIO

N

KP

C

FL

DA

VID F

OR

CE, S

E

A1EAST END CROSS SECTION SHOWING EXISTING SLAB - NEWSCALE: 1/4" = 1' 0 4' 8'2' SS-303SS-303

FE

B 2

019

ASS-501

E.J.

TOP OF SSP 582.5 TOP OF SSP 582.5

LAKESIDERIVERSIDE

GENERAL NOTES:

CENTERLINE OF EXISTING WALE EL. 581.25±

(VARIES & VERIFY)

EL. 546.7

EL. 531.7 (EVERY THIRD PILE)

BOTTOM OF EXISTING SSP EL. 534.75

2 - C9X20 WALE

NEW PZ27 SHEET PILE ANCHOR WALL

LONG

EVERY 3RD PILE 50'

PILE 35' LONG.

EXISTING SHEET

WALL CAP

CONCRETE

EXISTING 12"

DUCK BANK TO REMAIN

EXISTING UTILITY

EXISTING MZ-38 SSP WALL, WALE AND ANCHORS TO REMAIN

BACKFILL

(SEE CIVIL

SHEETS)

TOE STONE SEE CIVIL SHEETS

1

2.5

1

2

NEW HANDRAIL

NEW CONCRETE SLAB

EL 587.67 (FIELD VERIFY

TO MATCH EXISTING) EL. 588.0

AND BOTTOM

#8@12" O.C. TOP

TOP OF STONE 568.0 (MIN.)

EL. 534.5

NEW CA-7 BACKFILL

STRUCTUREEXISTING TUNNEL

1. CONCRETE COVER SHALL BE 4" CLEAR FOR SLABS OVER 24"

THICK.

TO MATCH C2/SS-501 AND REINFORCING

CONCRETE SLAB

Page 21: SD-301 - United States Army

2'-0"

10"

1'-0"

18'-0"±

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg12:56:38 PM 2/12/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\EAST END CROSS SECTION SHOWING NORTH BASIN WALL -

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

P

ROJE

CT I

D:

FIL

E N

AM

E:

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

FA

YE L

EFF

LE

R, P

ES

HO

WIN

G N

OR

TH B

ASIN W

ALL - N

EW

EA

ST E

ND C

RO

SS S

EC

TIO

N

SS-304

114419

KP

C

DA

VID F

OR

CE, S

E

FL

114419_S

S-3

04.d

gn

AN

SI

D

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

FA

YE L

EFF

LE

R, P

ES

HO

WIN

G N

OR

TH B

ASIN W

ALL - N

EW

EA

ST E

ND C

RO

SS S

EC

TIO

N

SS-304

KP

C

FL

DA

VID F

OR

CE, S

E

A1EAST END CROSS SECTION SHOWING NORTH BASIN WALL - NEWSCALE: 1/4" = 1' 0 4' 8'2'

BEAM POCKET

TOP OF SSP 582.5

RIVERSIDE

GENERAL NOTES:

EL. 546.7

EL. 531.7 (EVERY THIRD PILE)

NEW PZ27 SHEET PILE ANCHOR WALL

LONG

EVERY 3RD PILE 50'

PILE 35' LONG.

EXISTING SHEET

WALL CAP

CONCRETE

EXISTING 12"

DUCK BANK TO REMAIN

EXISTING UTILITY

STRUCTUREEXISTING TUNNEL

BACKFILL

(SEE CIVIL

SHEETS)

1

2.5

EL. 588.0

NEW CONCRETE SLAB

AND BOTTOM

#8@12" O.C. TOP

MASONRY VAULT

ABANDONED

REMOVE & REPLACE CHECKER PLATE

EXISTING NORTH BASIN WALL

1" GAP

EL. 534.5

LAKESIDE

TOE STONE SEE CIVIL SHEETS

TOP OF STONE 577.0 (MIN.)

1

2

1. CONCRETE COVER SHALL BE 4" CLEAR FOR SLABS OVER 24"

THICK.

Page 22: SD-301 - United States Army

6" MIN.1'-0"

1'-0"

1'-8"

1'-0"

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg12:56:47 PM 2/12/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\WEST END ENLARGED PLAN VIEW

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

P

ROJE

CT I

D:

FIL

E N

AM

E:

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

FA

YE L

EFF

LE

R, P

E114419

KP

C

DA

VID F

OR

CE, S

E

FL

114419_S

S-4

01.d

gn

AN

SI

D

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

FA

YE L

EFF

LE

R, P

E

KP

C

FL

DA

VID F

OR

CE, S

E

E7

SCALE: 3/8" = 1' 4'0 2' 8'SS-401

E1

B7

SCALE: 3/8" = 1' 4'0 2' 8'SS-401

C1

B1SCALE: 3/8" = 1' 4'0 2' 8'

DETAIL A

DETAIL B

PL

AN VIE

WP

LA

N VIE

W

WE

ST E

ND E

NL

AR

GE

D

SS-401

WE

ST E

ND E

NL

AR

GE

D

SS-401

WEST END ENLARGED PLAN VIEW

E9SCALE: 3/8" = 1' 4'0 2' 8'SS-402

D2 DETAIL B

BSS-401

NEW HANDRAIL

HANDRAIL

EXISTING

ASS-401

NEW METAL STAIR (SEE SPECIFICATIONS)

DOWN

DOWELS 12" FROM OUTSIDE FACE OF TUNNEL

EMBEDMENT INTO EXISTING. LOCATE

#5@12" O.C. DOWELS WITH MINIMUM 12"

EXPANSION JOINT

EXPANSION JOINT

EXPANSION JOINT

EXISTING TUNNEL ROOF SLAB

EXPANSION JOINT

#5@12" O.C. EACH WAY EACH FACE

NEW SLAB

NEW HANDRAIL

EXISTING SLAB

(TYP.)

EMBEDMENT

MINIMUM 12"

#5@12" DOWELS

NEW FLOOR SLAB

EXISITNG TUNNEL

SLAB

NEW CONCRETE

EXISTING TUNNEL ROOF SLAB

EXPANSION JOINT

(TYP.)

EMBEDMENT

MINIMUM 12"

#5@12" DOWELS

NEW FLOOR SLAB

EXISITNG TUNNEL

SLAB

NEW CONCRETE

#5@12" O.C. EACH WAY EACH FACE

Page 23: SD-301 - United States Army

4'-0"

18'-0"

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg12:56:54 PM 2/12/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\EAST END ENLARGED PLAN VIEW

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

P

ROJE

CT I

D:

FIL

E N

AM

E:

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

FA

YE L

EFF

LE

R, P

EP

LA

N VIE

W

EA

ST E

ND E

NL

AR

GE

D

SS-402

114419

KP

C

DA

VID F

OR

CE, S

E

FL

114419_S

S-4

02.d

gn

AN

SI

D

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

FA

YE L

EFF

LE

R, P

EP

LA

N VIE

W

EA

ST E

ND E

NL

AR

GE

D

SS-402

KP

C

FL

DA

VID F

OR

CE, S

E

A1SCALE: 3/8" = 1' 4'0 2' 8'

NORTHPLAN

EAST END ENLARGED VIEW PLAN

NEW HANDRAILS

BSS-401

ASS-304

ASS-305

EXPANSION JOINT

HANDRAIL IN KIND

REMOVE AND REPLACE

EXISTING HANDRAIL

RE-USE EXISTING GRATING

(TYP.)

TUNNEL WITH MINIMUM 12" EMBEDMENT

FROM OUTSIDE FACE OF EXISTING

#5@12" O.C. DOWELS LOCATED FROM 12"

NEW METAL STAIR (SEE SPECIFICATIONS)

ISOLATION JOINT ALIGN WITH CORNER OF "BELLY IN". THICKEN SLAB (12" WIDTH) TO MATCH DEPTH OF EXISTING SLAB.

Page 24: SD-301 - United States Army

1'-9"

1'-9"

1'-4"

1 1/2 "

3"

8"

6"

9"

SHEET PILE ALIGNMENTREQUIRED TO MATCH EXISTING SHALL BE SEGMENTED ONLY AS 0" TO 2" (MAX) ARMOR PLATE

25'-0" (MIN.)

1'-0"

1'-4"

3" CLEAR (TYP.)

3" CLEAR (TYP.)

1'-4" (MIN.)

SO

LICIT

ATIO

N N

O.:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

A

MA

RK

SIZ

E:

SU

BMIT

TE

D B

Y:

DA

TE

CO

NT

RA

CT N

O.:

CH

EC

KE

D B

Y:

DR

AW

N B

Y:

ISS

UE D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

TOP OF SSP

EL. 582.5 1/4" PER FOOT

1/4" PER FOOT TOP OF

CONCRETE

EL. 583.83

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg12:57:01 PM 2/12/2019

...\Chicago Lock North Pier Repair - 114419\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\TYPICAL CONCRETE CROSS SECTION AND REINFORCING

®of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

P

ROJE

CT I

D:

FIL

E N

AM

E:

CHIC

AG

O, IL

LIN

OIS 6

0604

231 S. L

AS

ALLE S

T, S

UIT

E 1

500

CHIC

AG

O DIS

TRIC

T

SE

CTIO

PN A

ND R

EIN

FO

RCIN

G

TY

PIC

AL C

ON

CR

ET

E C

RO

SS

114419

KP

C

114419_S

S-5

01.d

gn

AN

SI

D

CHIC

AG

O, IL

LIN

OIS

NO

RT

H PIE

R R

EP

AIR

S

CHIC

AG

O L

OC

K

SE

CTIO

PN A

ND R

EIN

FO

RCIN

G

TY

PIC

AL C

ON

CR

ET

E C

RO

SS

KP

C

C2SCALE: 3/4" = 1' 2'0 1' 4'

TYPICAL CONCRETE CROSS SECTION

FA

YE L

EFF

LE

R, P

E

DA

VII

D F

OR

CE, S

E

FL

FA

YE L

EFF

LE

R, P

E

FL

DA

VII

D F

OR

CE, S

E

A6SCALE: 1 1/2" = 1' 1' 2'0 6"SS-505

E2

SS-501

SS-501DETAIL A AT "BELLY OUT"

1

1

ASS-505

1/2"X12" PLATE

TOP OF SSP EL. 582.5±

TROWEL CONCRETE LEVEL W/ TOP OF SHEET PILE

EXISTING SHEET PILE

EXISTING WALE

BOTTOM ROWS (TYP.)

STAGGER MIDDLE ROW BETWEEN TOP &

5/8"ØX6" LONG HEADED STUDS @ 12" O.C.

CLHANDRAIL

TO FILL "BELLY OUTS" OF SHEET PILE

CONTINUOUSLY ON EXISTING WALE AND

CONCRETE BACKFILL TO BEAR

5/16

1/2" ARMOR PLATE WITH 6" RADIUS

GENERAL NOTES:

EL. 588.5

RIVERSIDE FACE

EL. 584.4± AT 25' FROM

RODS

EMBEDMENT. AVOID TIE

ROW (TYP.) MIN. 12"

STAGGER WITH ADJACENT

#6 DOWELS AT 24" O.C.

1. ANY SOIL EXCAVATED IN THE PARKING LOT FOR INSTALLATION OF THE TIE

RODS OR THE NEW SSP ANCHOR WALL SHALL BE DISPOSED OF OFFSITE BY

IAW SPECIFICATIONS. THE TOP 12" OF THE PARKING SURFACE SHALL BE

REPLACED IN KIND.

NEW HANDRAIL (TYP.)

#6@12" O.C.

#6@12" O.C.

#8@12" O.C.

#8@6" O.C.

WATERSTOP

HYDROPHILIC

CONTINUOUS

1" SQUARE

WATERSTOP

HYDROPHILIC

CONTINUOUS

1' SQUARE

TYPICAL HANDRAIL