scl – 61h ultrasonic water meter
TRANSCRIPT
Installation and User GuideSCL – 61H Ultrasonic Water Meter
Huizhong Instrumentation Co., Ltd.
00000240
Quality AssuranceThe meters are designed and manufactured in conformity to China national standard GB/T 778-2007 《Measurement of water in full flow in closed pipe and cold drinking water meter and hot water meter》.EX works calibration is made in conformity to China national standard JJG162-2009 《Cold water meter》.Manufacture certification: Measuring Apparatus Certificate Ji Zhi No.00000240 issued by the P.R.C.Measuring Equipment Type Approval Certificate 2013F185-13Authentication certificates grantedQuality Standard System GB/T 19001-2008/ISO 9001:2008Environment Management System GB/T 24001-2004/ISO 14001:2004Measurement Management System GB/T 19022-2003/ISO 10012:2003
Dear Users and Friends,Thanks for your choice of our company’s ultrasonic flow measuring meters. Huizhong Instrumentation Co., Ltd. is currently China’s R&D and manufacture base of series ultrasonic heat meters, water meters and flowmeters and related systems. It is also a new and hi-tech and software enterprise of Hebei province.In 2008,the company participated in the《research of the flow sensor and system for industrial process control system》-the 863 program assigned by the Ministry of Science and Technology.The research-derived achievements are constructive to the independent R&D and industrialization of advanced sensors in China.Incessant technical innovation lays a solid foundation which enables the company’s products to maintain all along technologically a leading position and win the acclaim of numerous users both at home and abroad for their leading technology and superior quality. Among them, the series ultrasonic flowmeters and water meters have been sold in batch quantities to Europe, African, North American and South Asian countries and regions, the products are well accepted by users.Huizhong Instrumentation Co., Ltd. innovate the ultrasonic flow measuring technology and energy management and control systems service capabilities to satisfy the needs of users with world-class products and services and make contributions to the development of global water and energy conservation course.
HUIZHONG
-1-
Important Tips:Please do read the Installation & User Guide carefully prior to the use of the meter.Please keep this instruction manual for reference whenever necessary.Please operate the meter strictly in accordance with the instructions. Huizhong bears no responsibility for any consequence resulted from user’s failure to follow the directives.All the diagrams shown in this instruction manual are illustrated instructions for operation, and do not serve as a basis for meter inspection. If there exists in the instruction manual any data that is inconsistent with that of the meter for use,take the meter actually used as the criterion, or consult with our company.The meter has been subjected to fine calibration before delivery. Huizhong bears no responsibility for any damage resulted from arbitrary disassemble of the meter by user.When the Symbol “ ” or “ ” comes to display, please refer to the List of Common Troubles for remedy. Otherwise, meter-measured data may get lost.If the meter does not work properly or it needs repair and maintenance, contact us or our authorized agency.Once the products were sold, prohibit opening the lead sealing, otherwise Huizhong bears no responsibility for any damage resulted from it.
Version No. Ver 2.00
Warning: Please proceed with your meter installation and operation strictly in accordance with the instructions for avoiding the loss of your interests.!
!
Factory lead sealing plug
Lead sealing hole for customer use
HUIZHONG
-2-
Contents
The meter is a precision device and must be operated by specialized personnel. Battery-related points for special attention:
Safety Warning: Please proceed with following precautions and use the meter correctly for avoiding economic loss, personal injury and death!!
1 Introduction …………………………………………………… 42 Technical Parameters ………………………………………… 53 Overall Dimensions …………………………………………… 74 Operating Instructions ………………………………………… 95 Installation and Connection ………………………………… 105.1 Requirements ………………………………………………… 105.2 Meter mounting location ……………………………………… 105.3 Mounting method ……………………………………………… 116 Replacement of Battery ……………………………………… 127 Calibration ……………………………………………………… 138 Fault Remedy and After-sales Service ……………………… 138.1 Correction of common troubles ……………………………… 138.2 After-sales service …………………………………………… 14
1
2
The used battery should be treated for environmental protection or sent to Huizhong for unified recovery and treatment.
When battery power is low, replace it in time. Otherwise, meter-measured data may get lost. The battery must be replaced by trained personnel or by Huizhong, if the meter is sent back to Huizhong by user.
HUIZHONG
-3-
SLC-61H ultrasonic water meter is designed to work on “propagation velocity difference” principle. It is a meter working with measurement-integration-display integrated functions and micro-power consumption technology (The lifetime of the battery is over 10 years). A flowrate as low as 0.006m3/h can be precisely measured. It enjoys the merits of being compacted in size and high in stability and anti-interference capability.Thanks to its use of ultrasonic measuring technology, the meter
environment or at places with heavy salt fog as the use of the meter under such an environment may accelerate ageing of manufacturing materials.
HUIZHONG
-4-
2. Technical Parameters (See Table 2-1)Table 2-1 Technical Parameters
Item ParameterDynamic Range ≥ 250Class of Measuring Accuracy 2
Nominal Diameter,mm DN15~DN25Max. Permissible working Pressure 1.6MPa
Ambient Temperature-25oC~+55oC RH ≤ 100%(If the range is exceeded, pls. specify on placing order)
Class of Temp. T30, T50, T70,default:T30Class of Upstream Flow Field Sensitivity U10
Class of Downstream Flow Field Sensitivity D5
HUIZHONG
-5-
Category of Climate & Mechanical Environment Conditions
C
Class of Electromagnetic Compatibility
E2
Pushbutton Photosensitive keyDisplay LC 8-digit + prompting charactersContents of Display Instantaneous flowrate, m3/h
Cumulative flowrate, m3
Water temperature, oCCumulative effective running time, hDate, Y/M/DClock, h/m/sSoftware versionScreen test
Display Resolution Cumulative flowrate: 0.001 m3
Water temperature: 0.01oCRange of Display Cumulative flowrate: 0 m3~99999.999 m3
Data Storage Storage of cumulative flow volume in EEPROM on a month by month basis. Data can be stored for a period of 100 years after power failure. The data of the past 24 months can be automatically stored.The cumulative flowrate of last seven days can be frozen.
Power Supply Battery DC 3.6V (The meter can work continuously for a period of over 10 years with one battery)
Power Consumption ≤ 0.2mWProtection Class IP68Storage Temperature -25oC~+55oCLength of Signal Cable 1.3mMeter Mounting Position On water supply pipe
HUIZHONG
-6-
Data Commu-nication
Photoelectric Interface
Baudrate: 2400bps Protocol: EN13757
RS-485/M-Bus
Baudrate: 2400bps, 4800bps, 9600bps (Selectable),Default: 2400bpsTransmission distance: ≤ 1200mProtocols: CJ/T 188;Huizhong;Modbus;EN 13757 (Selectable),Default: EN 13757
Radio Frequency
Transmission distance:2000m (Open space) Frequency band: 470MHz~510MHz
Meter Mounting Position On water supply pipe
3. Overall Dimensions (See Fig. 3-1)
Fig. 3-1 Overall Dimensions (Unit: mm)
Nominal diameter(mm) DN15 DN20 DN25
Permanent Flowrate Q3(m3/h)
1.6 2.5 1.6 2.5 4.0 4.0 6.3
Overload Flowrate Q4 (m3/h)
2.0 3.125 2.0 3.125 5.0 5.0 7.87
Boundary Flowrate Q2 (m3/h)
0.010 0.016 0.010 0.016 0.025 0.025 0.040
Min. Flowrate Q1 (m3/h)
0.006 0.010 0.006 0.010 0.016 0.016 0.025
Starting Flowrate (m3/h)
0.0015 0.0015 0.0026 0.00260.0026 0.004 0.004
Pressure Loss △P25△P63△P10△P25△P63△P25△P63
Range of Flowrate Parameters
RF output interface
HUIZHONG
-7-
Nominal Diameter DN15 DN20 DN25A: Meter mountedwithout connectingfittings
G1B
B: Meter mounted withconnecting fittings
R1
L(mm) 97L1(mm) 110 165 130 160H(mm) 123W(mm) 115Length of connectingfittings
45 59 59
Nominal Diameter DN15 DN20 DN25A: Meter mountedwithout connectingfittings
G1B
B: Meter mounted withconnecting fittings
R1
L(mm) 97L1(mm) 110 165 130 160H(mm) 94W(mm) 98Length of connectingfittings
45 51 59
34R 1
2R
34R 1
2R
34
34
G B
G B
14
14
G1 B
G1 B
M-BUS/ RS-485 output interface
HUIZHONG
-8-
Display Screen
Photoelectric Interface Photosensitive Key
4. Operating Instructions
The photosensitive key can be used to switch to the various displays as desired for the view of the various measured data which appear cyclically as follows:
Front panel annotation
Operating GuideMain screen display
Cumulative Flowrate, m3
Note:Symbol on display: If the key is not pressed on any screen display, the display stays 3 minutes and switches automatically back to main screen display.No symbol on display: If the key is not pressed on any screen display, the display stays 3 minutes and then automatically goes off.
!
!
HUIZHONG
-9-
Display Screen
5. Installation and Connection5.1 Requirements
5.2 Meter mounting location
The meter must be mounted at the design-specified position. It is strictly forbidden to mount it at other points.Replacement of battery must be done by professional personnel.
A vertical pipe with upward (or oblique upward) flow is the most preferable location, followed by a horizontal pipe. Never mount the meter on a pipe with downward or oblique downward flow for in this case the pipe may not be full of flow.
Cumulative Flowrate, m3
Instantaneous Flowrate, m3/h
Cumulative Effective Running Time, h
Alternation between all on and all off
Supply Water Temp., oC
Software Version
Date, Y/M/D
Clock, h/m/s
HUIZHONG
-10-
Never mount the meter on the highest point of a pipe run as the meter can not work properly because of the collection of air bubbles.
5.3 Mounting method
Mounting method 1: Meter mounted without connecting fittings
Mounting method 2: Meter mounted with connecting fittingsCut apart the pipe at the point for meter mounting to leave the
Cut apart the pipe at the point for meter mounting to leave the required mounting space (See Fig. 5-1).
Fig. 5-1 Meter Mounting Diagrammatic Sketch 1
Fig. 5-2 Meter Mounting Diagrammatic Sketch 2
Align concentrically the meter and pipe. Screw the unions on the meter’s connecting threads and then tighten up with a spanner (See Fig. 5-2).
The installation position of RF ultrasonic water meter should far from magnetic field, and the distance from meter antenna to wall is farther than 50mm.
Care must be taken to sealing work in connection for avoiding leakage.The direction of arrow on the side of the meter’s pipe section must correspond to the direction of flow!
Notice:
!
Direction of Flow
HUIZHONG
-11-
Mounting method 1: Meter mounted without connecting fittings
Direction of Flow
required mounting space for mounting meter and connecting fittings (See Fig. 5-3).
Screw the connecting fittings onto pipe ends (See Fig. 5-4).Fig. 5-3 Meter Mounting Diagrammatic Sketch 3
Fig. 5-4 Meter Mounting Diagrammatic Sketch 4
Fig. 5-5 Meter Mounting Diagrammatic Sketch 5
It is a 3.6V lithium battery with a lifetime of over 10 years under an ambient temperature of 0oC~35oC. When the symbol “ ” is on display, it indicates the battery is low and needs to be replaced for avoiding loss of measured data. Replacement of battery must be made by trained professional personnel or alternatively, have the meter sent back to Huizhong for battery replacement. After battery is replaced, the cumulative flowrate and cumulative effective running time remain in storage.
6. Replacement of Battery
HUIZHONG
-12-
Trouble Cause Remedial Measure
“ ” keeps on display
1. No water in pipe2. Thick scale deposit on transducer surface3. Faulty meter
1. Keep pipe full of flow2. Remove3. Contact Huizhong
“ ” frequently on display
Excessive air bubbles or impurities in water or medium
Remove
Display of “ ” Low battery Replace soon
Display of
Battery too low in power with a voltage as low as 3.15 as indicated. Now, measurements are interrupted but view of stored data is possible
Battery must be replaced
Display of “88888888”
Faulty EEPROM Contact Huizhong immediately for repair
In case of fault, first refer to the trouble remedy guide. If no ready solution can be found there, please contact Huizhong for remedy.
Table 8-1 List of Common troubles
!
!
HUIZHONG
-13-
The meter is calibrated in compliance with the Standard JJG 162-2000《Regulations on calibration of cold water meter》using the associated special tool – handheld infrared data reader. For the setting of calibration mode and related parameters, refer to Hand-held Infrared Data Reader Instruction Manual.
8. Fault Remedy and After-sales Service8.1 Correction of common troubles
7. Calibration
Repair of any meter beyond its guaranty period will be made on site, if required, with the travel expenses and cost of components covered by user.The free repair provisions shall not cover any of the following damages:Damage of meter due to purely artificial reasons, such as mechanical impact.After-sales service rendered for the repair of any meter damage caused not by the failure of the meter itself but for the shut-down or abnormal operation of system or user’s failure to operate the meter according to the instructions.Damage of meter caused by force of majeure, such as thunder strike.For the repair work done on site for the abovementioned reasons, the travel expenses and costs of components shall be covered by user.If the user sends the meter’s core part or the entire meter back to Huizhong for repair, both parties shall respectively bear the transportation expenses and the costs of components for replacing damaged ones shall be borne by user.
4
5
6
Huizhong Instrumentation Co., Ltd. operates by adhering to the principle of “being user’s most trustworthy friend and providing users our quality products and timely first-rate after-sales service”. Our specific commitments are as follows:
8.2 After-sales service
After receiving user’s call, we promise to make a response within 2 hours.We promise to repair any meter within one year after its date of delivery free of charge without asking for the costs of labor and components.“Free repair” is only limited to the repair of the damaged main measuring unit and key functional components like transducers. Repair of damaged cables is outside the promised scope.
1
2
3
HUIZHONG
-14-
Huizhong Instrumentation Co., Ltd. Address: No.126 West Gaoxin Road, High-Tech Industrial Development Zone, Tangshan, Hebei, China 063020Marketing Hotline:0315-3208504,3205102Fax: 0315-3190081Postcode: 063020E-mail: [email protected]://www.hzyb.com
All rights reserved. Technical parametersare subject to change without prior notice.