school byelaws

Upload: manogna-kavuru

Post on 04-Apr-2018

232 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/30/2019 school byelaws

    1/14

  • 7/30/2019 school byelaws

    2/14

    EDUCATIONAL

    BUILDING

    Laying down thelaw in your buildingor associationdoesn't have to be apainful process.When it comes tocreating house orcommunity rules,careful planningand a healthy doseof common sensecan make theprocess smooth,leading to happierhomeowners and astress-freeexecutive board.

    SCHOOL

  • 7/30/2019 school byelaws

    3/14

    No basement or cellar room shall be designed, constructed,

    altered, converted or used for the purpose of study orinstruction.

    Every such building, exceeding two storey in height shall beconstructed of fire resisting material throughout.

    The minimum size of a cellar room, study room or room used forpurposes of instruction shall be 5.5 mt. x 4.5 mt. and

    no part of such room shall be distant more than 7.5 mt. from anexternal wall abutting on the requisite open space

    Every such room shall have a minimum ventilation to the extentof 1/5th of its floor area.

  • 7/30/2019 school byelaws

    4/14

    A minimum of 1.0sq.mt. of net floorspace per studentshall be provided.

    A central hall willnot be counted inthe

    accommodation,nor will a classroom for cookery,laundry, manualinstruction,drawing or science.

  • 7/30/2019 school byelaws

    5/14

    Every assembly room, gymnasium shall have a clear heightof 3.6 mt. except under a girder which may project 0.6 mt.below the required ceiling height.

    Assembly/Playground Area-8x27mA clear internal height under balcony or a girder shall notbe less than 3.0 mt.

    A minimum room height for classroom in all schools and

    other institutions shall not be less than 3.0 mt. Theminimum head room under beams shall be 2.75 mt.Classrooms height provided in the school is 3.5 m and thehead room height is 3 m

    No door shall be less than 1.2 mt. in width and 2.20 mt. inheight.Door width is 1.2 m and the height is 2.20mThe number of students in such building shall be calculatedon this basis for the purpose of this clause

  • 7/30/2019 school byelaws

    6/14

    Separate conveying system to be provided for sewerage andsullage to facilitate reuse of sullage water for gardening andwashing purposes.

    Separate conveying system is not provided. This may require suitable storage facilities that are to be

    indicated on the building plans.

    For recharging ground water, rainwater-harvestingprovisions are to be provided within the plot, which are to beindicated on the building plans.

    The recharging ground water,rainwater-harvesting

    provisions are not provided within the plot

  • 7/30/2019 school byelaws

    7/14

    The external enclosing walls of the staircase shall be of thebrick or the R.C.C. construction having the fire resistance ofnot less than two hours.

    All enclosed staircases shall have access through self-closingdoor of one-hour fire resistance.

    These shall be single swing doors opening in the direction ofthe escape.

    The door shall be fitted with the check action door closers.

    Width of the staircase is 1.2m No.of steps - 25

  • 7/30/2019 school byelaws

    8/14

    All buildings of 15 mt. and above in height shall be equippedwith fire alarm system.

    Institutional buildings(Occupants per unit exit width)

    Stairways 25Ramps 50Doors 75

  • 7/30/2019 school byelaws

    9/14

    Equivalent Car Spaces (ECS) pre 100 sq. mt. of floor area0.50 - 1.50

    For the provision of car parking spaces, the space standardsshall be as under:i)For open parking 18.0 sq.mt. per equivalent car space.Ii)For ground floor covered parking 23.0 sq.mt. per equivalentcar space.

    iii)For basement 28.0 sq.mt. per equivalent car space.In the use premises, parking on the above standards may beprovided on the ground floor, or in the basement (where theprovision exists).

    Parking spaces are not provided

  • 7/30/2019 school byelaws

    10/14

    If abutting road is between 9m-12m wide then the plot size can bebetween 100-2000sq.m

    Minimum abutting road should be 12m wide, if

  • 7/30/2019 school byelaws

    11/14

    A strip of at least 1m greenery / lawn along the frontage of the site

    within the front setback shall be developed and maintained withgreenery.

    Greenery/lawn is not provided.

    For Plots above 300sq.m , a minimum 1m wide continuous greenplanting strip in the periphery on remaining sides are required tobe developed and maintained within the setback.

    For all institutional plots above 750sq.m, 5% of the site area to bedeveloped as organized open space and be utilized as greenery,tot lot or soft landscaping etc., and shall be provided over andabove the mandatory setbacks. Such organized open space couldbe in more than one location and shall be of a minimum width of3m with a minimum area of 15sq.m at each location

    -

  • 7/30/2019 school byelaws

    12/14

    In all plots 750 sq.m-1000 sq.m, provision shall bemade for earmarking an area of 3m X 3m for thepurpose of setting of public utilities like distributiontransformer, etc. within the owners site subject tomandated public safety requirements

    Distribution transformers are not provided

    In case of plots 750sq.m-1000sq.m, it is permitted totransfer up to 2m of setback from any one side to anyother side without exceeding overall permissibleplinth area, subject to maintaining of a minimum2.5m setback on other side and a minimum building

    line. The transfer of setback from front setback is notallowed.

  • 7/30/2019 school byelaws

    13/14

    Staff rooms-6.3X6.8M

    Classrooms-6.3X6.8M

    Store rooms-4.5X5M

    Toilets for boys-(13)-1.5X0.8M

    Toilets for girls- (11)- 1.5X0.8M

  • 7/30/2019 school byelaws

    14/14

    Generator space-Not Provided

    Garbage disposal- Provided

    Sewerage lines- Provided

    Water supply- Provided

    Electricity- Provided