schneider electric - relay's catalog sept 09

80
Electromechanical and solid-state relays Zelio Relay Catalogue September 2009

Upload: john

Post on 18-Nov-2014

2.645 views

Category:

Documents


0 download

DESCRIPTION

Relay's CatalogSeptember 2009Relay's General Catalog

TRANSCRIPT

Page 1: Schneider Electric - Relay's Catalog Sept 09

Electromechanicaland solid-state relaysZelio RelayCatalogueSeptember 2009

Page 2: Schneider Electric - Relay's Catalog Sept 09
Page 3: Schneider Electric - Relay's Catalog Sept 09

1

Reduce the size of yourenclosures and, at thesame time, increasemachine reliability

Make the most of your energy

ContentsPresentationChoose compactness with Zelio Relay RSL ....................................................................... 2-3Choose long life and silent operation with Zelio Relay SSR ................................................. 4-5Electromechanical and solid-state relays panorama ........................................................... 6-7

Technical characteristicsZelio Relay RSL ................................................................................................................................. 8-15Zelio Relay RSB, RXM, RUM, RPM ............................................................................................ 16-49Zelio Relay ABR, ABS .................................................................................................................... 50-69Zelio Relay SSR .............................................................................................................................. 70-77

The new Zelio Relay itemsElectromechanical relays RSLOnly 6 mm wide, thus saving considerable spacein your enclosures

Solid-state relays SSRUnlimited service life provided by electronic technology

6 mm wide

Unlimited service life

Page 4: Schneider Electric - Relay's Catalog Sept 09

2

Choose compactnesswith Zelio Relay RSL

Only 6 mmwide, thus reducing the sizeof your enclosures

> A solution forany application

A complete offer

> An offer with maximum flexibility, comprising:• complete products: a single reference for a relaymounted on a socket,

• products for customer assembly: select the relayand associated socket according to your application.> Wide choice of sockets available covering a rangeof voltages from 12 to 230 V.

An offer that meets the mostdemanding standards

• Conformity with the European RoHS(Restriction of Hazardous Substances) directive.• Conformity to international standardsIEC/EN 61810-1, UL508, CSA C22.2 N°14, GOST.

100% RoHSSchneider Electric commits itself toreducing the environmental impactof its products

Page 5: Schneider Electric - Relay's Catalog Sept 09

3

> Reliability in any situation

Protection integrated in the socket

The assurance of reliable protection of the relayirrespective of the supply voltage used.

LED indicator

Power on and relay status LED indicator.

«Standard» and «low level»version relays

For high breaking capacity or low levelcurrent application requirements.

> Simplicity of installationand cabling

Simple maintaining of relay in socketand its release/removalUsing locking/unlocking lever.

Simplification of cablingCommoning link available as accessory.

Simple mounting on DIN rail

Choice of 2 connection techniquesSuitable for the majority of your applications.

Up to 6Abreaking capacity

Spring terminalScrew connector

Page 6: Schneider Electric - Relay's Catalog Sept 09

44

Choose long life andsilent operation withZelio Relay SSR

> Heat exchange guaranteedThe new solid-state relays SSR with SCR (SemiconductorControlled Rectifier) outputs offer you two alternatives:

SSRD rangeDirectly mounted with heat sink to provide heat exchange,they are easily mounted by clipping directly onto DIN rail andcan also be panel mounted.

SSRP rangePanel mounted, either on their own or combined witha heat sink for applications requiring considerable heat exchange.

SSRP relay mounted on heat sink withthermal interface

SSRAH1

ASSEMBLED IN MEXICO

0812

Page 7: Schneider Electric - Relay's Catalog Sept 09

5

> Distinctive indicationA green LED on the front face of the products provides instantindication of the relay input status.

> High performanceHigh breaking capacities• From 10 to 125 A for relays SSRP• From 10 to 45 A for relays SSRD

Wide supply voltage range• From 3 to 32 VDC and 90 to 280 VAC

Outputs suited to applications• From 24 to 280 VAC and 48 to 530/660 VAC

Extreme compactness• Only 22.5 mm and up to 45.5 mm wide

Unlimited service life• No preventive maintenance, relays SSR have aunlimited service life

Silence of electronic technology• Complete silence when switching

Insensitive to vibration• Even in the event of excessive vibration, the relaywill not change state

> Conformity tointernational standards

100%RoHS

Schneider Electric commits

itself to reducing the environmental

impact of its products

Unlimitedservice lifedue to electronic relaytechnology

Completesilence whenswitchingproviding suitability forbuilding and hospitalapplications

High switchingfrequencyparticularly on packagingand textile machines

Page 8: Schneider Electric - Relay's Catalog Sept 09

Panorama Zelio Relay

Number CO contacts

Current

References

1 CO 1 or 2 CO 1 or 2 CO 2, 3 or 4 CO 1, 2, 3 or 4 CO

6 A 8-12-16 A 5-12 A 6-10-12 A 10 A 15A

RSL RSB ABR RXM RUM RPM

8 to 15 16 to 21 50 to 69 22 to 29 30 to 39 40 to 49Pages

Electromechanical relays

Plugs into socket On DIN rail Plugs into socketMounting

1 NO

3 A

ABS

50 to 69 70 to 77 70 to 77

Solid-state relays

2, 3 or 4 CO

On DIN rail On DIN rail

1 NO

10 ...45 A 10 ...125 A

1 NO

On panel

SSRD SSRP

Electromechanical relay advantages

• Wide choice of number of contacts (up to 4)• Easy installation and maintenance:

Plug-in relay for socket mounting (universal format)Contact status mechanical indicator and “Relay On” LED indicatorLockable “Test” button for testing relay operation

• Electrically separated inputs and outputs, allowing different voltages

Page 9: Schneider Electric - Relay's Catalog Sept 09

Number CO contacts

Current

References

1 CO 1 or 2 CO 1 or 2 CO 2, 3 or 4 CO 1, 2, 3 or 4 CO

6 A 8-12-16 A 5-12 A 6-10-12 A 10 A 15A

RSL RSB ABR RXM RUM RPM

8 to 15 16 to 21 50 to 69 22 to 29 30 to 39 40 to 49Pages

Electromechanical relays

Plugs into socket On DIN rail Plugs into socketMounting

1 NO

3 A

ABS

50 to 69 70 to 77 70 to 77

Solid-state relays

2, 3 or 4 CO

On DIN rail On DIN rail

1 NO

10 ...45 A 10 ...125 A

1 NO

On panel

SSRD SSRP

Solid-state relay (SSR) advantages

• Unlimited service life• Wide supply voltage range and high breaking current(up to 125 A), suited to packaging and textile machines• “Relay On” LED indicator• Completely silent switching, providing suitability forbuilding and hospital applications• Insensitive to vibration

Page 10: Schneider Electric - Relay's Catalog Sept 09

2

1

3

4

5

6

7

8

9

10

Application Plug-in relays

Number and type of contacts / conventional thermal current (Ith on N/O contact)

1 C/O / 6 A

Control voltage range c 12…60 V

Contact type Standard YesLow level Yes

Type of pins Flat (PCB type, reinforced)

Operating voltage Up to a 400 V / c 300 V

Durability(operating cycles)

Electrical, resistive load 60 000Mechanical, no-load 10 000 000

Relay type RSL 1pB4pD

Pages 14

Conventional thermal current (Ith) 6 A 6 A

Connection Screw connector Spring terminals

LED Yes Yes

Protection circuit Yes Yes

Accessories Socket identification legend Yes YesBus jumper Yes YesPartition plate Yes Yes

Socket type RSL ZVpp RSL ZRpp

Pages 14 14

Slim interface relays, pre-assembled RSL 1PVpp RSL 1PRpp

Pages 14 14

Selection guide Zelio Relay - plug-in relaysRSL slim interface relays

PF0

9021

1P

F090

209

PF0

9020

6

Page 11: Schneider Electric - Relay's Catalog Sept 09

2

1

3

4

5

6

7

8

9

10

99

Application Plug-in relays

Number and type of contacts / conventional thermal current (Ith on N/O contact)

1 C/O / 6 A

Control voltage range c 12…60 V

Contact type Standard YesLow level Yes

Type of pins Flat (PCB type, reinforced)

Operating voltage Up to a 400 V / c 300 V

Durability(operating cycles)

Electrical, resistive load 60 000Mechanical, no-load 10 000 000

Relay type RSL 1pB4pD

Pages 14

Conventional thermal current (Ith) 6 A 6 A

Connection Screw connector Spring terminals

LED Yes Yes

Protection circuit Yes Yes

Accessories Socket identification legend Yes YesBus jumper Yes YesPartition plate Yes Yes

Socket type RSL ZVpp RSL ZRpp

Pages 14 14

Slim interface relays, pre-assembled RSL 1PVpp RSL 1PRpp

Pages 14 14

PF0

9021

0P

F090

207

Page 12: Schneider Electric - Relay's Catalog Sept 09

2

1

3

4

5

6

7

8

9

10

1010

Presentation Zelio Relay - plug-in relaysRSL slim interface relays

PresentationRSL slim interface relays offer the advantages of compact size and modular design: their slim width (6 mm) saves space when mounting on a 5 rail at the back of an enclosure.

RSL relays are available in two versions:pre-assembled range: a single reference comprising a relay mounted on its

socket. The socket includes a protection circuit (against reverse polarity and surge) and

an LED indicator as standard.Two types of connector are available for wire connection: screw connectors or

spring terminals. This pre-assembled solution covers a wide range of operating voltages from 12 to

230 V.range for customer assembly: The relay (standard or low level) and the socket are selected, as required,

according to the operating voltage of the application. For maintenance: an RSL slim relay can be replaced without any need to

disconnect the socket wiring.

b

v

v

v

bv

v

DescriptionRSL slim interface relays, pre-assembled

6 A relay (standard or low level) with 1 C/O contact.Lever for retaining, or easy withdrawal of the relay from its socket. Sockets: wire connection by screw connector or by spring terminals.All sockets have a built-in protection circuit and LED indicator.

1 2 3 4

RSL slim interface relay

Five flat, reinforced pins (PCB type).1

Sockets for RSL slim interface relays

Five female contacts for the relay pins.Retaining lever with marker label.Wire connection by screw connector or by spring terminals.Protection circuit and LED indicator (built into the socket)Locating slot for mounting on 5 rail.

1 2 3 4 5

Presentation : page 10

Characteristics : page 11

References : page 14

Dimensions, schemes : page 15

1

2

3

4

PF0

9021

3

1

PF0

9020

1

24

5

3

PF0

9021

2

Page 13: Schneider Electric - Relay's Catalog Sept 09

2

1

3

4

5

6

7

8

9

10

1111

Characteristics Zelio Relay - plug-in relaysRSL slim interface relays

General characteristicsConforming to standards

IEC 6110-1, UL 50, CSA C22-2 No. 14

Product certifications

UL, CSA, GOST

Ambient air temperature around the device

Storage

°C - 40… + 5

Operation

°C - 40… + 55

Vibration resistanceconforming to IEC/EN 6006-2-6

In operation

10 gn

Not operating

5 gn

Degree of protection Conforming to IEC/EN 60529

IP 40 (Relays)IP 20 (Sockets)

Shock resistanceconforming to IEC/EN 6006-2-27

Opening

10 gn

Closing

5 gn

Protection category

RT III

Mounting position

Any

Insulation characteristicsRated insulation voltage (Ui)

V 250 (IEC)

Rated impulse withstand voltage (Uimp)

kV 6

Dielectric strength(rms voltage)

Between coil and contact

a V 4000

Between contacts

a V 1000

Page 14: Schneider Electric - Relay's Catalog Sept 09

2

1

3

4

5

6

7

8

9

10

1212

Characteristics (continued) Zelio Relay - plug-in relaysRSL slim interface relays

Contact characteristicsRelay type RSL1ABppp RSL1GBppp

Number and type of contacts 1 C/O 1 C/O low level

Contact materials AgSnO2 AgSnO2 - gold plated

Conventional thermal current (Ith)

For ambient temperature y 55 °C

A 6 6

Rated operational current in utilisation categories AC-1 and DC-1

Conforming to IEC N/C A 6 6N/O A 6 6

Conforming to UL A 6 6

Switching current Minimum mA 100 1 (at 50 mW)

Switching voltage Rated a V 250 250Maximum V a 400, c 300 a 250, c 300 Minimum V 12 1 (at 50 mW)

Nominal load (resistive) A 6 / a 250 V, 0.5 mm

Switching capacity Maximum a VA 1500c W 1…150 (depending on the voltage)

Minimum mW 120 50

Maximum operating rateIn operating cycles

No-load 72 000Under load 360

Mechanical durability In millions of operating cycles 10

Electrical durabilityIn millions of operating cycles

Resistive load See curves below

Inductive load 0.05 (N/O contact /250 V, 3 A, AC-15)

Maximum switching capacity on c load Electrical durability

Current c

Volta

ge c

0,1 0,2 0,5 1 10 202 510

20

30

5040

100

200

300

Resistive load

Cyc

les

Switching current (A)

104

105

106

107

0 1 2 3 4 5 6 7 8

Resistive load a 250V

AgSnO2

Coil characteristicsAverage consumption c W 0.17

Drop-out voltage threshold c u 0.05 UcOperating time(response time)

Between coil energisation and making of the On-delay contact

c ms 12 max

Between coil de-energisation and making of the Off-delay contact

c ms 5 max

Control circuit voltage Uc V 12 24 48 60Relay control voltage codes JD BD ED ND

DC supply Average resistance at 23 °C ± 10% Ω 4 3390 10 600 20 500

Operating voltage limits Min. V .4 16. 33.6 42Max. V 16. 33.6 67.2 4

Presentation : page 10

Characteristics : page 11

References : page 14

Dimensions, schemes : page 15

Page 15: Schneider Electric - Relay's Catalog Sept 09

2

1

3

4

5

6

7

8

9

10

1313

Socket characteristicsSocket type RSL ZVpp RSL ZRpp

Relay types used RSL 1pppp RSL 1pppp

Conforming to standards IEC 6194, UL 50, CSA C22-2 No. 14Product certifications UL, CSA, GOSTContact terminal arrangement Separate SeparateWire connection method Screw connector Spring terminalsWidth mm 6.2 6.2

Electrical characteristicsConventional thermal current (Ith) A 6Maximum operating voltage V 300

Insulation characteristicsBetween adjacent output contacts Vrms 2500Between input and output contacts Vrms 2500Between contacts and 5 rail Vrms 2500

General characteristicsAmbient air temperaturearound the device

Operation °C - 40…+ 70 / - 40…+ 55 for U > 0 VStorage °C - 40…+ 5

Degree of protection Conforming to IEC/EN 60529 IP 20Cabling Solid cable

without cable end1 conductor mm² 0.2…2.5 0.2…1.5

AWG 24…14 24…16 Flexible cable with cable end

1 conductor mm² 0.2…2.5 0.2…1.5AWG 24… 14 24…16

Screw size mm M 2.5Maximum tightening torque Nm 0.5 10 N…40 N (0.2 …1.5 mm²)

Mounting On 35 mm 5 railFixing on 5 rail By plastic compression spring

Terminal referencing IECLED indicator Yes (built-in)

Protection circuit Yes (built-in)Wire connection method Screw connector Spring terminal

Sockets operating voltageOperating voltage Tolerance Control circuit voltage (relay)V V

Socket type RSLZVA1, RSLZRA1 c/a 12 + 20% / - 5% c 12

c/a 24 + 20% / - 10% c 24

RSLZVA2, RSLZRA2 c/a 4 + 20% / - 10% c 4

c/a 60 + 20% / - 10% c 60

RSLZVA3, RSLZRA3 c/a 110 + 15% / - 20% c 60

RSLZVA4, RSLZRA4 c/a 230 + 15% / - 20% c 60

Characteristics (continued) Zelio Relay - plug-in relaysRSL slim interface relays

Page 16: Schneider Electric - Relay's Catalog Sept 09

2

1

3

4

5

6

7

8

9

10

1414

References Zelio Relay - plug-in relaysRSL slim interface relays

Slim interface relays, pre-assembledRelays mounted on socket equipped with LED and protection circuitSold in lots of 101 C/O contact - Thermal current (Ith) 6AOperating voltage Control circuit voltage Socket type

Screw connector Spring terminalUnit reference Weight Unit reference Weight

V V kg kgc/a 12 c 12 RSL 1PVJU 0.031 RSL 1PRJU 0.029

c/a 24 c 24 RSL 1PVBU 0.031 RSL 1PRBU 0.029

c/a 48 c 48 RSL 1PVEU 0.031 RSL 1PREU 0.029

c/a 110 c 60 RSL 1PVFU 0.031 RSL 1PRFU 0.029

c/a 230 c 60 RSL 1PVPU 0.031 RSL 1PRPU 0.029

Slim interface relays for customer assembly: relay + socketRelays with flat, reinforced pins (PCB type)Sold in lots of 101 C/O contact - Thermal current (Ith) 6A

Standard Low levelControl circuit voltage Unit reference Weight Unit reference WeightV kg kg

c 12 RSL 1AB4JD 0.006 RSL 1GB4JD 0.006

c 24 RSL 1AB4BD 0.006 RSL 1GB4BD 0.006

c 48 RSL 1AB4ED 0.006 RSL 1GB4ED 0.006

c 60 RSL 1AB4ND 0.006 RSL 1GB4ND 0.006

Sockets equipped with LED and protection circuitSold in lots of 10

Socket typeScrew connector Spring terminal

Operating voltage For use with relays Unit reference Weight Unit reference WeightV kg kg

c/a 12 and c/a 24 RSL 1pB4JDRSL 1pB4BD

RSL ZVA1 0.025 RSL ZRA1 0.023

c/a 48 and c/a 60 RSL 1pB4EDRSL 1pB4ND

RSL ZVA2 0.025 RSL ZRA2 0.023

c/a 110 RSL 1pB4ND RSL ZVA3 0.025 RSL ZRA3 0.023

c/a 230

RSL 1pB4ND RSL ZVA4 0.025 RSL ZRA4 0.023

Accessories for socketsSold in lots of 10Description Compatibility Unit reference Weight

kgClip-in legends(sheet of 64 legends)

With all sockets RSL Z5 0.001

Bus jumper (20-pole jumper)

With all sockets RSL Z2 0.003

Partition plate With all sockets RSL Z3 0.001

Presentation : page 10

Characteristics : page 11

References : page 14

Dimensions, schemes : page 15

RSL 1pppp

PF0

9021

1

RSL ZVAp

PF0

9020

9

RSL 1PVpp

PF0

9020

6

RSL ZRAp

PF0

9021

0

RSL 1PRpp

PF0

9020

7

RSL Z2

RSL Z3

Page 17: Schneider Electric - Relay's Catalog Sept 09

2

1

3

4

5

6

7

8

9

10

1515

Dimensions, schemes

Zelio Relay - plug-in relaysRSL slim interface relays

Slim interface relays, pre-assembledRSL 1PVpp (screw connector) RSL 1PRpp (spring terminals)

95

30,1

51,5 6,2 6,2

78,6

101

35,3

6,251,5 6,2

78,6

Relays for customer assemblyRSL 1pppp with flat, reinforced pins (PCB type)

(1): 5.04 mm

1,9

(1)

(1)

3,5±0,5

11,3

43,

78

15 max 5 max

2 m

ax

1 C/O contact

A1

A2

1211

14

Sockets equipped with LED and protection circuitRSL ZVpp (screw connector) RSL ZRpp (spring terminals)

95

30,1

51,5 6,2 6,2

78,6

101

35,3

6,251,5 6,2

78,6

Socket connections Example of RSL Z2 bus jumper mounting on sockets

RSL ZVpp (screw connector) RSL ZRpp (spring terminals) Side view

Protection circuit

14

11

A1

A2

12

12

11

14

A1

A2

Protection circuit

12

11

14

A1

A2

1411

A1

A212

(4)(2)

(1)(3)

(1) A1(2) A2(3) Bus jumper polarity A1(4) Bus jumper polarity A2

Page 18: Schneider Electric - Relay's Catalog Sept 09

16

Selection guide

Universal relays Power relays

2 C/O / 10 A3 C/O / 10 A3 C/O / 3 A (low level)

2 C/O / 10 A3 C/O / 10 A

1 C/O / 15 A2 C/O / 15 A3 C/O / 15 A4 C/O / 15 A

24…230 V 24…230 V12…220 V 12…110 V 12…110 V

Cylindrical Flat (Faston type) Flat (Faston type)

Up to 250 V Up to 250 V

100 000 100 000 (3)5 000 000 10 000 000

Yes (depending on version) Yes (depending on version)Yes YesYes YesYes (depending on version) – –

RUM RPM

33 43

12 A 16 A

Mixed Separate Mixed

Connector Screw clamp terminals

Yes YesYes Yes (for 3 and 4-pole)Yes Yes (on socket RPZ F1)Yes Yes– Yes– Yes– Yes –

RUZ CpM RUZ SCpM RUZ SF3M RPZ Fp

34 34 44(3) 100 000 for RPM1 and RPM2; 60 000 for RPM3 and RPM4.

Application Plug-in relaysInterface relays Miniature relays

Number and type of contacts / conventional thermal current (Ith on N/O contact)

1 C/O / 16 A1 C/O / 12 A2 C/O / A

2 C/O / 12 A3 C/O / 10 A4 C/O / 6 A4 C/O / 3 A (low level)

Control circuit voltage a 24…240 V 24…240 Vc 6…110 V 12…220 V

Type of pins Flat (Faston type) Flat (Faston type)

Operational voltage Up to a 400 V / c 300 V Up to 250 V

Durability (operating cycles)

Electrical, resistive load 100 000 100 000Mechanical, no-load 30 000 000 10 000 000

Functions LED Yes (with protection modules) Yes (depending on version)Mechanical indicator – YesLockable test button – YesLow level contacts – Yes (depending on version)

Type reference RSB RXM

Pages 20 25 and 26

Conventional thermal current (Ith) 12 A (1) 10 A 12 A (2)

Contact terminal arrangements Separate Mixed Separate

Connection Connector Screw clamp terminals or connector

Connector

Accessories Protection modules Yes YesTimer module – –Maintaining clamps Yes YesSocket identification legend Yes Yes (except RXZ E2M114)Mounting adapters for 5 rail – YesMounting adapters with fixing lugs – YesBus jumper, 2-pole (Ith = 5 A) – – Yes

Associated socket types RSZ E1SppM RXZ E2Mppp RXZ E2Sppp

Pages 20 26 26(1) When using relay RSB 1A160pp with socket RSZ E1S48M, terminals must be linked.(2) Except for sockets RXZ E2S11pM: 10 A.

Zelio Relay - plug-in relays

1

2

3

4

5

6

7

8

9

10

Page 19: Schneider Electric - Relay's Catalog Sept 09

17

Universal relays Power relays

2 C/O / 10 A3 C/O / 10 A3 C/O / 3 A (low level)

2 C/O / 10 A3 C/O / 10 A

1 C/O / 15 A2 C/O / 15 A3 C/O / 15 A4 C/O / 15 A

24…230 V 24…230 V12…220 V 12…110 V 12…110 V

Cylindrical Flat (Faston type) Flat (Faston type)

Up to 250 V Up to 250 V

100 000 100 000 (3)5 000 000 10 000 000

Yes (depending on version) Yes (depending on version)Yes YesYes YesYes (depending on version) – –

RUM RPM

33 43

12 A 16 A

Mixed Separate Mixed

Connector Screw clamp terminals

Yes YesYes Yes (for 3 and 4-pole)Yes Yes (on socket RPZ F1)Yes Yes– Yes– Yes– Yes –

RUZ CpM RUZ SCpM RUZ SF3M RPZ Fp

34 34 44(3) 100 000 for RPM1 and RPM2; 60 000 for RPM3 and RPM4.

Application Plug-in relaysInterface relays Miniature relays

Number and type of contacts / conventional thermal current (Ith on N/O contact)

1 C/O / 16 A1 C/O / 12 A2 C/O / A

2 C/O / 12 A3 C/O / 10 A4 C/O / 6 A4 C/O / 3 A (low level)

Control circuit voltage a 24…240 V 24…240 Vc 6…110 V 12…220 V

Type of pins Flat (Faston type) Flat (Faston type)

Operational voltage Up to a 400 V / c 300 V Up to 250 V

Durability (operating cycles)

Electrical, resistive load 100 000 100 000Mechanical, no-load 30 000 000 10 000 000

Functions LED Yes (with protection modules) Yes (depending on version)Mechanical indicator – YesLockable test button – YesLow level contacts – Yes (depending on version)

Type reference RSB RXM

Pages 20 25 and 26

Conventional thermal current (Ith) 12 A (1) 10 A 12 A (2)

Contact terminal arrangements Separate Mixed Separate

Connection Connector Screw clamp terminals or connector

Connector

Accessories Protection modules Yes YesTimer module – –Maintaining clamps Yes YesSocket identification legend Yes Yes (except RXZ E2M114)Mounting adapters for 5 rail – YesMounting adapters with fixing lugs – YesBus jumper, 2-pole (Ith = 5 A) – – Yes

Associated socket types RSZ E1SppM RXZ E2Mppp RXZ E2Sppp

Pages 20 26 26(1) When using relay RSB 1A160pp with socket RSZ E1S48M, terminals must be linked.(2) Except for sockets RXZ E2S11pM: 10 A.

1

2

3

4

5

6

7

8

9

10

Page 20: Schneider Electric - Relay's Catalog Sept 09

1

Presentation of the rangeThe RSB interface relay range comprises: 1 12 A relays with 1 C/O contact , 16 A relays with 1 C/O contact and A relays with

2 C/O contacts.2 Sockets with separate contact terminals.3 Protection modules (diode, diode + LED, RC circuit or varistor + LED). All these

modules are common to all sockets.4 A plastic maintaining clamp for all sockets.5 Clip-in legends for the sockets.

Socket descriptionSockets with separate contact terminals (1)

1 Connection by connector. 2 Five or eight female contacts for the relay pins.3 A fixing hole for panel mounting.4 Location for protection modules.5 Locking components for plastic maintaining clamp.6 Locating slot for mounting on 5 rail.

(1) The inputs and outputs are separated from the relay supply.

General characteristics

Conforming to standards IEC/EN 6110-1, UL 50, CSA C22-2 n° 14Product certifications UL, CSAAmbient air temperature around the device

Storage °C - 40…+ 5Operation °C c - 40…+ 5, a - 40...+ 70

Vibration resistance Conforming to IEC/EN 6006-2-6 > 10 gn (10..150 Hz)Degree of protection Conforming to IEC/EN 60529 IP 40Shock resistanceconforming to IEC/EN 6006-2-27

Opening 5 gnClosing 10 gn

Protection category RT IMounting position AnyInsulation characteristics

Rated insulation voltage (Ui) Conforming to IEC/EN 60947 V 400Rated impulse withstand voltage (Uimp) kV 3.6 (1.2/50 µs)Dielectric strength(rms voltage)

Between coil and contact a V 5000Between poles a V 2500Between contacts a V 1000

Contact characteristicsRelay type RSB 1A120pp RSB 1A160pp RSB 2A080pp

Number and type of contacts 1 C/O 1 C/O 2 C/OContact materials AgNiConventional thermal current (Ith)

For ambient temperature y 40°C

A 12 16

Rated operational current in utilisation categories AC-1 and DC-1

Conforming to IEC “C” A 12 16 “O” A 6 4

Switching current Minimum mA 5Switching voltage Maximum V a 400, c 300

Minimum V 5Nominal load (resistive) A 12 / 250 a V 16 / 250 a V / 250 a V

A 12 / 2 c V 16 / 2 c V / 2 c VSwitching capacity Maximum a VA 3000 4000 2000

c W 336 44 224Minimum mW 300

Maximum operating rateIn operating cycles/hour

No-load 72 000Under load 600

Zelio Relay - plug-in relaysRSB interface relays

Presentation, characteristics

5351

1

2

35

6

4

Inputs

Outputs

Relay supply

5

4

1

5231

39

2

3

Presentation:page 1

References:page 20

Characteristics:page 19

Dimensions, schemes:page 21

1

2

3

4

5

6

7

8

9

10

Page 21: Schneider Electric - Relay's Catalog Sept 09

19

Contact characteristics (continued)Relay type RSB 1A120pp RSB 1A160pp RSB 2A080pp

Mechanical durability In millions of operating cycles u 30Electrical durabilityIn millions of op. cycles

Resistive load 12 A - 250 V: u 0.1 16 A - 250 V: u 0.07 A - 250 V: u 0.1Inductive load See curves below

Electrical durability of contactsResistive load a

Reduction coefficient for inductive load a (depending on power factor cos j)

Maximum switching capacity on resistive load c

A RSB 2A080pp B RSB 1A160pp C RSB 1A120pp. Durability (inductive load) = durability (resistive load) x reduction coefficient.Coil characteristics

Average consumption c 0.45 W, a 0.75 VADrop-out voltage threshold ≥ c 0.1 Uc, ≥ a 0.15 UcOperating time(response time)

Between coil energisation and making of the On-delay contact

a ms 12c ms 9

Between coil de-energisation and making of the Off-delay contact

a ms 10c ms 4

Control circuit voltage Uc V 6 12 24 48 60 110 120 220 230 240Relay control voltage codes RD JD BD ED ND FD – – – –

d.c. supply Average resistance at 20 °C ± 10% W 90 360 1440 5700 7500 25 200 – – – –Operating voltage limits

Min. V 4. 9.6 19.2 3.4 4 – – – –Max. V 6.6 13.2 26.4 52. 66 121 – – – –

Relay control voltage codes – – B7 E7 – – F7 M7 P7 U7a.c. supply 60 Hz

Average resistance at 20 °C ± 15% W – – 400 1550 – – 10 200 35 500 3 500 42 500Operating voltage limits

Min. 50 Hz V – – 19.2 3.4 – – 96 176 14 19260 Hz – – 20.4 40. – – 102 17 195.5 204

Max. 50/60 Hz V – – 26.4 57.6 – – 144 264 276 2Socket characteristicsSocket type RSZ E1S35M RSZ E1S48MRelay types used RSB 1A120pp RSB 2A080pp, RSB 1A160pp (1)

Contact terminal arrangement SeparateWire connection method ConnectorProduct certifications e

Conforming to standards IEC 6194, UL, CSAElectrical characteristics

Conventional thermal current (Ith) A 12Maximum operating voltage V 300Insulation characteristics

Between adjacent output contacts Vrms 2500Between input and output contacts Vrms 2500Between contacts and 5 rail Vrms 2500General characteristics

Ambient air temperaturearound the device

Operation °C - 25…+ 5Storage °C - 40…+ 5

Degree of protection Conforming to IEC/EN 60529 IP 20Cablingscrew connector

Solid cable without cable end

1 conductor 0.5…2.5 mm2 - AWG 20…AWG 142 conductors 0.5…1.5 mm2 - AWG 20…AWG 16

Flexible cable with cable end

1 conductor 0.25…2.5 mm2 - AWG 22…AWG 142 conductors 0.25…1 mm2 - AWG 22…AWG 17

Maximum tightening torque / Screw size Nm 0. / M3 screwMounting On 35 mm 5 rail / on panelFixing on 5 rail By plastic compression springTerminal referencing IECBus jumper (Ith: 5 A) NoCompatibility with the metal maintaining clamp Yes, plasticTimer module NoProtection module All RZM pppClip-in legends YesWire connection method Screw connector

(1) When using the relay with socket RSZ E1S48M, terminals must be linked. See connection schemes on page 21.

104

0,80 0,4 1,21 1,6 2

107

105

106

C

A

B

Dur

abili

ty (N

umbe

r of o

pera

ting

cycl

es)

Switching capacity (kVA)

104

0,80 0,4 1,21 1,6 2

107

105

106

C

A

B

Dur

abili

ty (N

umbe

r of o

pera

ting

cycl

es)

Switching capacity (kVA)

0,3

0,5

0,61 0,4 0,2

0,4

0,60,

1

Red

uctio

n co

effic

ient

(A)

0,3

0,5

0,61 0,4 0,2

0,4

0,60,

1

Red

uctio

n co

effic

ient

(A)

0,1

12

16

100 200 30010 20 30 50

5

12

0,5

50

CB

A

Cur

rent

c

Voltage c

0,1

12

16

100 200 30010 20 30 50

5

12

0,5

50

CB

A

Cur

rent

c

Voltage c

Zelio Relay - plug-in relaysRSB interface relays

Characteristics

1

2

3

4

5

6

7

8

9

10

Page 22: Schneider Electric - Relay's Catalog Sept 09

20

Relays for standard applicationsControl circuit voltage

Sold in lots of

Number and type of contacts - Thermal current (Ith)1 C/O - 12 A 1 C/O - 16 A 2 C/O - 8 AUnit reference (1)

Unit reference (1)

Unit reference (1)

Weight

V kgc 6 10 RSB 1A120RD RSB 1A160RD RSB 2A080RD 0.014

c 12 10 RSB 1A120JD RSB 1A160JD RSB 2A080JD 0.014

c 24 10 RSB 1A120BD RSB 1A160BD RSB 2A080BD 0.014

c 4 10 RSB 1A120ED RSB 1A160ED RSB 2A080ED 0.014

c 60 10 RSB 1A120ND RSB 1A160ND RSB 2A080ND 0.014

c 110 10 RSB 1A120FD RSB 1A160FD RSB 2A080FD 0.014

a 24 10 RSB 1A120B7 RSB 1A160B7 RSB 2A080B7 0.014

a 4 10 RSB 1A120E7 RSB 1A160E7 RSB 2A080E7 0.014

a 120 10 RSB 1A120F7 RSB 1A160F7 RSB 2A080F7 0.014

a 220 10 RSB 1A120M7 RSB 1A160M7 RSB 2A080M7 0.014

a 230 10 RSB 1A120P7 RSB 1A160P7 RSB 2A080P7 0.014

a 240 10 RSB 1A120U7 RSB 1A160U7 RSB 2A080U7 0.014

Sockets 12 A, a 300 VContact terminal arrangement

Connection Relay type Sold in lots of

Unit reference

Weightkg

Separate Connector RSB 1A120pp 10 RSZ E1S35M 0.060RSB 1A160pp (2)RSB 2A00pp

10 RSZ E1S48M 0.050

Protection modulesDescription For

use withVoltage Sold in

lots ofUnit reference

Weight

V kgDiode All sockets c 6…230 10 RZM 040W 0.003

RC circuit All sockets a 24…60 10 RZM 041BN7 0.010a 110…240 10 RZM 041FU7 0.010

Diode + green LED All sockets c 6…24 10 RZM 031RB 0.004c 24…60 10 RZM 031BN 0.004c 110…230 10 RZM 031FPD 0.004

Varistor + green LED All sockets c or a 6…24 10 RZM 021RB 0.005c or a 24…60 10 RZM 021BN 0.005c or a 110…230 10 RZM 021FP 0.005

AccessoriesDescription For

use withSold in lots of

Unit reference

Weightkg

Plastic maintaining clamp All sockets 10 RSZ R215 0.002Legend All sockets 10 RSZ L300 0.001

(1) To order a relay complete with socket (sold in lots of 20): add suffix S to one of the following voltage codes JD, BD, B7, P7 or F7. Example: RSB 2A080BD + RSZ E1S48M becomes RSB 2A080RBS.

(2) When using the relay with socket RSZ E1S48M, terminals must be linked. See connection schemes on page 21.

RSB 1A120JD + RZM 031FPD + RSZ E1S35M

5605

3

RSB 1A120JD + RZM 031FPD + RSZ E1S35M

5605

3

RSB 1A160BD + RSZ E1S48M

5605

4

RSB 1A160BD + RSZ E1S48M

5605

4

RSB 2A080BD + RSZ E1S48M

5605

2

RSB 2A080BD + RSZ E1S48M

5605

2

RSZ R215

5605

5

RSZ R215

5605

5Zelio Relay - plug-in relaysRSB interface relays

References

Presentation:page 1

References:page 20

Characteristics:page 19

Dimensions, schemes:page 21

1

2

3

4

5

6

7

8

9

10

Page 23: Schneider Electric - Relay's Catalog Sept 09

21

DimensionsInterface relaysRSB 1A120pp RSB 2A080pp, RSB 1A160pp

SocketsRSZ E1S35M RSZ E1S48M

(1) Relays(2) Protection module(3) Maintaining clamp(4) Legend

SchemesInterface relaysRSB 1A120pp RSB 1A160pp RSB 2A080pp

When using relay RSB 1A160pp with socket RSZ E1S48M terminals 11 and 21, 14 and 24, 12 and 22 must be linked

Protection modulesRZM 040W RZM 041ppp RZM 031ppp RZM 021ppp

– A2

+ A1

– A2

+ A1

– A2

+ A1

– A2

+ A1

15,7

7,5

3,5

12,5

3,929

16,5

2,5

3,5

15,7

7,5

3,5

12,5

3,929

16,5

2,5

3,5

15,7

7,5

5

12,5

3,9

5 29

152,

5

15,7

7,5

5

12,5

3,9

5 29

152,

5

61

67

78,5

(4)

15,5

29,4

34,5

50

27,5

(3)

(1)

(2)

11

14

12

A2 A1

61

67

78,5

(4)

15,5

29,4

34,5

50

27,5

(3)

(1)

(2)

11

14

12

A2 A1

(4)

21 11

24 14

22 12

A2 A1

61

67

78,5

15,5

29,4

34,5

50

27,5

(3)

(1)

(2)

(4)

21 11

24 14

22 12

A2 A1

61

67

78,5

15,5

29,4

34,5

50

27,5

(3)

(1)

(2)

A2

A1

111412

A2

A1

11

14

12

A2

A1

111412

A2

A1

11

14

12

A2

A1

21 11

22 12

24 14

A2

A1

11/2

114

/24

12/2

2

A2

A1

21 11

22 12

24 14

A2

A1

11/2

114

/24

12/2

2

A2

A1

21 11

22 12

24 14

A2

A1

212422

111412

A2

A1

21 11

22 12

24 14

A2

A1

212422

111412

Dimensions, schemes

Zelio Relay - plug-in relaysRSB interface relays

1

2

3

4

5

6

7

8

9

10

Page 24: Schneider Electric - Relay's Catalog Sept 09

22

Presentation of the range The RXM miniature relay range comprises: 1 12 A relays with 2 C/O contacts, 10 A relays with 3 C/O contacts, 6 A relays with

4 C/O contacts and 3 A “low level” relays with 4 C/O contacts. All these relays have the same dimensions.

2 Sockets with mixed or separate contact terminals.3 Protection modules (diode, RC circuit or varistor). All these modules are common

to all sockets.4 A metal maintaining clamp for all sockets.5 A plastic maintaining clamp for all sockets.6 A 2-pole bus jumper that can be used on sockets with separate contact terminals

in order to simplify cabling when creating an equipotential link between the coil terminals.

7 Clip-in legends for all the sockets except RXZ E2M114.

Relay description 1 Spring return pushbutton for testing the contacts (green: c, red: a). 2 Mechanical “relay status” indicator.3 Removable lock-down door enabling forced maintaining of the contacts for test

sequences or maintenance purposes. During operation, this lock-down door must always be in the closed position.

4 LED (depending on version) indicating the relay status.5 Removable legend for relay identification.6 Four notches for rail mounting adapter or panel mounting adapter with fixing lugs.7 Eight, eleven or fourteen Faston type pins.8 Area by which the product can be easily gripped.9 Mounting adapter enabling direct mounting of the relay on a panel.10 Mounting adapter enabling direct mounting of the relay on a 5 rail.

Socket description Sockets with mixed contact terminals (1)

1 Connection by screw clamp terminals or screw connector.2 Fourteen female contacts for the relay pins.3 Location for protection modules.4 Locking components for plastic and metal maintaining clamps.5 Locating slot for mounting on 5 rail with its compression spring or fixing clip.6 Two or four fixing holes for panel mounting.

Sockets with separate contact terminals (2)1 Connection by screw connector. 2 Eight, eleven or fourteen female contacts for the relay pins.3 Location for protection modules.4 Locking components for plastic and metal maintaining clamps.5 Locating slot for mounting on 5 rail with its compression spring or fixing clip.6 Two fixing holes for panel mounting.7 Location for bus jumpers (see mounting on sockets on page 2).

(1) The inputs are mixed with the relay's supply, with the outputs being located on the opposite side of the socket.

(2) The inputs and outputs are separated from the relay supply.

5247

66 7

6

2

1

5

3

4or

5247

66 7

6

2

1

5

3

4or

1065

57 12

7

3

4

56

8

1065

57 12

7

3

4

56

8

1066

60 9

1066

60 9

1066

61 9

1066

61 9

1066

62 10

1066

62 10

1060

14 1

2

3

4

5

Outputs

Inputs

Relay supply5

6

1060

14 1

2

3

4

5

Outputs

Inputs

Relay supply5

6

1060

15 16

2

3

4

5 7

Outputs

Inputs

Relay supply5

1060

15 16

2

3

4

5 7

Outputs

Inputs

Relay supply5

Zelio Relay - plug-in relaysRXM miniature relays

Presentation

Presentation :page 22

Characteristics :pages 23 and 24

References :pages 25 and 26

Dimensions :pages 27 and 2

Schemes :page 29

Presentation :page 22

Characteristics :pages 23 and 24

References :pages 25 and 26

Dimensions :pages 27 and 2

Schemes :page 29

1

2

3

4

5

6

7

8

9

10

Page 25: Schneider Electric - Relay's Catalog Sept 09

23

General characteristicsConforming to standards IEC/EN 6110-1 (iss. 2), UL 50, CSA C22-2 n° 14Product certifications UL, CSAAmbient air temperature around the device

Storage °C - 40… + 5Operation °C - 40… + 55

Vibration resistanceconforming to IEC/EN 6006-2-6

In operation 3 gn (10...150 Hz/± 1 mm / 5g/5 cycles)Not operating 5 gn (10...150 Hz/± 1 mm / 5g/5 cycles)

Degree of protection Conforming to IEC/EN 60529 IP 40Shock resistanceconforming to IEC/EN 6006-2-27

Opening 15 gnClosing 15 gn

Protection category RT IMounting position Any

Insulation characteristicsRated insulation voltage (Ui) V 250 (IEC), 300 (UL, CSA)Rated impulse withstand voltage (Uimp) kV 4 (1.2/50 ms)Dielectric strength(rms voltage)

Between coil and contact a V 1550Between poles a V 1550Between contacts a V 1500

Contact characteristicsRelay type RXM 2ABppp RXM 3ABppp RXM 4ABppp RXM 4GBppp

Number and type of contacts 2 C/O 3 C/O 4 C/O 4 C/O low levelContact materials AgNi AgAu - bifurcatedConventional thermal current (Ith)

For ambient temperature y 55 °C

A 12 10 6 3

Rated operational current in utilisation categories AC-1 and DC-1

Conforming to IEC "C" 12 10 6 2“O” 6 5 3 1

Conforming to UL 12 10 6 3Switching current Minimum mA 10 3Switching voltage Maximum V a/c 250 (IEC)

Minimum V 17 5Nominal load (resistive) A 12 / 250 a V 10 / 250 a V 6 / 250 a V 3 / 250 a V

A 12 / 2 c V 10 / 2 c V 6 / 2 c V 3 / 2 c VSwitching capacity Maximum a VA 3000 2500 1500 750

c W 336 20 16 4Minimum mW 170 15

Maximum operating rateIn operating cycles

No-load 1 000Under load 1200

Utilisation coefficient 20 %Mechanical durability In millions of operating cycles 10

Electrical durabilityIn millions of operating cycles

Resistive load 0.1Inductive load See curves below

Electrical durability of contacts Resistive load a

Reduction coefficient for inductive load a (depending on power factor cos j)

Maximum switching capacity on resistive load c

A RXM 2ABppp B RXM 3ABppp C RXM 4ABppp D RXM 4GBppp

Durability (inductive load) = durability (resistive load) x reduction coefficient.

105

106

107

2 30 1

A BDC

Dur

abili

ty (N

umbe

r of o

pera

ting

cycl

es)

Switching capacity (kVA)

105

106

107

2 30 1

A BDC

Dur

abili

ty (N

umbe

r of o

pera

ting

cycl

es)

Switching capacity (kVA)

0,3

0,5

0,61 0,4 0,2

0,4

0,60,

1

Red

uctio

n co

effic

ient

(A)

0,3

0,5

0,61 0,4 0,2

0,4

0,60,

1

Red

uctio

n co

effic

ient

(A)

0,1

1

200 2500 5028 100 150

10

3

6

CDBA

Cur

rent

c

Voltage c

0,1

1

200 2500 5028 100 150

10

3

6

CDBA

Cur

rent

c

Voltage c

Zelio Relay - plug-in relaysRXM miniature relays

Characteristics

1

2

3

4

5

6

7

8

9

10

Page 26: Schneider Electric - Relay's Catalog Sept 09

24

Coil characteristicsAverage consumption a VA 1.2

c W 0.9Drop-out voltage threshold a u 0.15 Uc

c u 0.1 UcOperating time(response time)

Between coil energisation and making of the On-delay contact

a ms 20c ms 20

Between coil de-energisation and making of the Off-delay contact

a ms 20c ms 20

Control circuit voltage Uc V 12 24 48 110 120 125 220 230 240Relay control voltage codes JD BD ED FD – GD MD – –

d.c. supply Average resistance at 20 °C ± 10% W 160 650 2600 11 000 – 11 000 14 000 – –Operating voltage limits Min. V 9.6 19.2 3.4 – 100 176 – –

Max. V 13.2 26.4 52. 121 – 13 242 – –Relay control voltage codes – B7 E7 F7 – – P7 U7

a.c. supply Average resistance at 20 °C ± 15% W – 10 770 – 4430 – – 15 000 15 500Operating voltage limits Min. V – 19.2 3.4 – 96 – – 14 192

Max. V – 26.4 52. – 132 – – 253 264

Socket characteristicsSocket type RXZ E2S108M RXZ E2S111M RXZ E2S114M RXZ E2M114M RXZ E2M114Relay types used RXM 2ppppp RXM 3ppppp RXM 4ppppp RXM 2ppppp (1)

RXM 4pppppRXM 2ppppp (1)RXM 4ppppp

Contact terminal arrangement Separate MixedWire connection method Connector Screw clamp

terminalsProduct certifications UL, CSAConforming to standards IEC 6194, e

Electrical characteristicsConventional thermal current (Ith) A 12 10Maximum operating voltage V 250 (IEC)

Insulation characteristicsBetween adjacent output contacts Vrms 2500Between input and output contacts Vrms 2500Between contacts and 5 rail Vrms 2500

General characteristicsAmbient air temperaturearound the device

Operation °C - 40…+ 55Storage °C - 40…+ 5

Degree of protection Conforming to IEC/EN 60529 IP 20Cabling Solid cable

without cable end

1 conductor 0.5…2.5 mm2 - AWG 20…AWG 14 0.5… 1.5 mm2 AWG 20…AWG 16

2 conductors 0.5…1.5 mm2 - AWG 20…AWG 16Flexible cable with cable end

1 conductor 0.25…2.5 mm2 - AWG 22…AWG 14 0.25…1 mm2

AWG 22…AWG 172 conductors 0.25…1 mm2 - AWG 22…AWG 17

Maximum tightening torque / Screw size Nm 1 / M3 screwMounting On 35 mm 5 rail / on panelFixing on 5 rail By red plastic clip By metal

compression spring

By red plastic clip

Terminal referencing IEC, NEMABus jumper (Ith: 5 A) Yes NoCompatibility with the plastic maintaining clamp YesCompatibility with the metal maintaining clamp YesProtection module All RXM 040W, RXM 041pp, RXM 021pp

Clip-in legends Yes NoWire connection method Screw connector Screw clamp

terminals

(1) When mounting relay RXM 2ppppp on socket RXZ E2Mpppp, the thermal current must not exceed 10 A.

Zelio Relay - plug-in relaysRXM miniature relays

Characteristics (continued)

Presentation :page 22

Characteristics :pages 23 and 24

References :pages 25 and 26

Dimensions :pages 27 and 2

Schemes :page 29

Presentation :page 22

Characteristics :pages 23 and 24

References :pages 25 and 26

Dimensions :pages 27 and 2

Schemes :page 29

1

2

3

4

5

6

7

8

9

10

Page 27: Schneider Electric - Relay's Catalog Sept 09

25

Miniature relays without LED (sold in lots of 10) Control circuit voltage

Number and type of contacts - Thermal current (Ith)2 C/O - 12 A 3 C/O - 10 A 4 C/O - 6 AUnit reference

Weight Unit reference

Weight Unit reference

Weight

V kg kg kgc 12 RXM 2AB1JD 0.037 RXM 3AB1JD 0.037 RXM 4AB1JD 0.037c 24 RXM 2AB1BD 0.037 RXM 3AB1BD 0.037 RXM 4AB1BD 0.037c 4 RXM 2AB1ED 0.037 RXM 3AB1ED 0.037 RXM 4AB1ED 0.037c 110 RXM 2AB1FD 0.037 RXM 3AB1FD 0.037 RXM 4AB1FD 0.037c 220 – – – – RXM 4AB1MD 0.037

a 24 RXM 2AB1B7 0.037 RXM 3AB1B7 0.037 RXM 4AB1B7 0.037a 4 RXM 2AB1E7 0.037 RXM 3AB1E7 0.037 RXM 4AB1E7 0.037a 120 RXM 2AB1F7 0.037 RXM 3AB1F7 0.037 RXM 4AB1F7 0.037a 230 RXM 2AB1P7 0.037 RXM 3AB1P7 0.037 RXM 4AB1P7 0.037a 240 – – – – RXM 4AB1U7 0.037

Miniature relays with LED (sold in lots of 10) c 12 RXM 2AB2JD 0.037 RXM 3AB2JD 0.037 RXM 4AB2JD 0.037c 24 RXM 2AB2BD 0.037 RXM 3AB2BD 0.037 RXM 4AB2BD 0.037c 4 RXM 2AB2ED 0.037 RXM 3AB2ED 0.037 RXM 4AB2ED 0.037c 110 RXM 2AB2FD 0.037 RXM 3AB2FD 0.037 RXM 4AB2FD 0.037c 125 – – – – RXM 4AB2GD 0.037

a 24 RXM 2AB2B7 0.037 RXM 3AB2B7 0.037 RXM 4AB2B7 0.037a 4 RXM 2AB2E7 0.037 RXM 3AB2E7 0.037 RXM 4AB2E7 0.037a 120 RXM 2AB2F7 0.037 RXM 3AB2F7 0.037 RXM 4AB2F7 0.037a 230 RXM 2AB2P7 0.037 RXM 3AB2P7 0.037 RXM 4AB2P7 0.037

Miniature relays with low level contacts, without LED (sold in lots of 10) Control circuit voltage

Number and type of contacts Thermal current (Ith)4 C/O - 3 AUnit reference

Weight

V kgc 12 RXM 4GB1JD 0.037c 24 RXM 4GB1BD 0.037c 4 RXM 4GB1ED 0.037c 110 RXM 4GB1FD 0.037

a 24 RXM 4GB1B7 0.037a 4 RXM 4GB1E7 0.037a 120 RXM 4GB1F7 0.037a 230 RXM 4GB1P7 0.037

Miniature relays with low level contacts, with LED (sold in lots of 10) c 12 RXM 4GB2JD 0.037c 24 RXM 4GB2BD 0.037c 4 RXM 4GB2ED 0.037c 110 RXM 4GB2FD 0.037

a 24 RXM 4GB2B7 0.037a 4 RXM 4GB2E7 0.037a 120 RXM 4GB2F7 0.037a 230 RXM 4GB2P7 0.037a 240 RXM 4GB2U7 0.037

RXM pAB1F7

1066

5

RXM pAB1F7

1066

5

RXM pAB2F7

1066

57

RXM pAB2F7

1066

57

RXM 4GB1F7

1065

5

RXM 4GB1F7

1065

5

RXM 4GB2F7

1066

57

RXM 4GB2F7

1066

57

Zelio Relay - plug-in relaysRXM miniature relays

References

1

2

3

4

5

6

7

8

9

10

Page 28: Schneider Electric - Relay's Catalog Sept 09

26

Miniature relays without LED (sold in lots of 100)Control circuit voltage

Number and type of contacts - Thermal current (Ith)2 C/O - 12 A 4 C/O - 6 AUnit reference

Weight Unit reference

Weight

V kg kgc 12 – – RXM 4AB1JDTQ 0.036c 24 RXM 2AB1BDTQ 0.037 RXM 4AB1BDTQ 0.036c 4 – – RXM 4AB1EDTQ 0.036c 110 – – RXM 4AB1FDTQ 0.036c 220 – – RXM 4AB1MDTQ 0.036

a 24 RXM 2AB1B7TQ 0.037 RXM 4AB1B7TQ 0.036a 4 – – RXM 4AB1E7TQ 0.036a 120 RXM 2AB1F7TQ 0.037 RXM 4AB1F7TQ 0.036a 230 RXM 2AB1P7TQ 0.037 RXM 4AB1P7TQ 0.036

Miniature relays with LED (sold in lots of 100)c 24 – – RXM 4AB2BDTQ 0.036a 24 RXM 2AB2B7TQ 0.037 RXM 4AB2B7TQ 0.036a 230 RXM 2AB2P7TQ 0.037 RXM 4AB2P7TQ 0.036

SocketsContact terminal arrangement

Connection Relay type Sold in lots of

Unit reference

Weightkg

Mixed Screw clamp terminals RXM 2pppp (3)RXM 4pppp

10 RXZ E2M114 (1) 0.04

Screw connector RXM 2pppp (3)RXM 4pppp

10 RXZ E2M114M (1) 0.056

Separate Screw connector RXM 2pppp 10 RXZ E2S108M (2) 0.05RXM 3pppp 10 RXZ E2S111M (1) 0.066RXM 4pppp 10 RXZ E2S114M (1) 0.070

Protection modulesDescription Voltage For

use withSold in lots of

Unit reference

Weight

V kgDiode c 6...250 All sockets 20 RXM 040W 0.003

RC circuit a 24...60 All sockets 20 RXM 041BN7 0.010a 110...240 All sockets 20 RXM 041FU7 0.010

Varistor a/c 6...24 All sockets 20 RXM 021RB 0.030a/c 24...60 All sockets 20 RXM 021BN 0.030a/c 110...240 All sockets 20 RXM 021FP 0.030

Timing relaysDescription For

use withUnit reference

Weightkg

2 or 4 timed C/O contacts (function A)

Sockets RXZ Eppppp RE XL2pp (4) –RE XL4pp (4) –

AccessoriesDescription For

use withSold in lots of

Unit reference

Weightkg

Metal maintaining clamp All sockets 10 RXZ 400 0.001Plastic maintaining clamp All sockets 10 RXZ R335 0.005Bus jumper 2-pole (Ith: 5 A) All sockets with separate contacts 10 RXZ S2 0.005

Mounting adapter for 5 rails (5)

All relays 10 RXZ E2DA 0.004

Mounting adapter with fixing lugs for panel

All relays 10 RXZ E2FA 0.002

Clip-in legends All relays (sheet of 10 legends) 10 RXZ L520 0.00All sockets except RXZ E2M114 10 RXZ L420 0.001

(1) Thermal current Ith: 10 A(2) Thermal current Ith: 12 A(3) When mounting relay RXM 2ppppp on socket RXZ E2Mpppp, the thermal current must not exceed 10 A. (4) Please consult the "Zelio Time timing relays" catalogue.(5) Test button becomes inaccessible.

RXZ E2M114M + Relais RXM 4AB2F7

1060

16

RXZ E2M114M + Relais RXM 4AB2F7

1060

1610

6017

RXZ E2S114M + Relais RXM 4AB2F7

1060

17

RXZ E2S114M + Relais RXM 4AB2F7

1060

1

RXM 041pp7

1060

1

RXM 041pp7

5351

95

RE XL4pp

5351

95

RE XL4pp

5364

4

RXZ 400

5364

4

RXZ 400

Presentation :page 22

Characteristics :pages 23 and 24

References :pages 25 and 26

Dimensions :pages 27 and 2

Schemes :page 29

Presentation :page 22

Characteristics :pages 23 and 24

References :pages 25 and 26

Dimensions :pages 27 and 2

Schemes :page 29

Zelio Relay - plug-in relaysRXM miniature relays

References (continued)

1

2

3

4

5

6

7

8

9

10

Page 29: Schneider Electric - Relay's Catalog Sept 09

27

DimensionsMiniature relaysRXM pppppp RXM 2 RXM 3 RXM 4

Common view Pin side view

SocketsRXZ E2M114 RXZ E2M114M

Common side view RXZ E2S108M RXZ E2S111M RXZ E2S114M

(1) Relays(2) Protection module(3) Maintaining clamp(4) 2 elongated holes Ø 3.5 x 6.5(5) 2 bus jumpers

(1)

(2)(3)

25,5

347

A214

A113

246

448

145

12

1

11

9

21

10

31

11

41

12

22

2

32

3

42

4

(4)19

40

309

232130

697

39,5

61

3,5

79

(4)

(1)

(2)(3)

25,5

347

A214

A113

246

448

145

12

1

11

9

21

10

31

11

41

12

22

2

32

3

42

4

(4)19

40

309

232130

697

39,5

61

3,5

79

(4)

17

43

23,550

27677

40

80

44

8

34

7

24

6

14

5

42

4

32

3

22

2

12

1

A1

13

A2

1441

12

31

11

21

10

11

9

(3)

(1)

(2)

17

43

23,550

27677

40

80

44

8

34

7

24

6

14

5

42

4

32

3

22

2

12

1

A1

13

A2

1441

12

31

11

21

10

11

9

(3)

(1)

(2)

19

61

2923

707

3,5

79

(3) (2)

(1)

(5)

19

61

2923

707

3,5

79

(3) (2)

(1)

(5)23,5

27

38

41

12

11

9

44

8

14

5

A1

13

A2

14

42

4

12

1

23,5

27

38

41

12

11

9

44

8

14

5

A1

13

A2

14

42

4

12

1

23,5

27

38

319

346

A1

13

A2

14

32

3

218

245

22

2

117

144

12

1

23,5

27

38

319

346

A1

13

A2

14

32

3

218

245

22

2

117

144

12

1

23,5

27

38

41

12

31

11

21

10

11

944

8

34

7

24

6

14

542

4

32

3

22

2

12

1

A1

13

A2

14

23,5

27

38

41

12

31

11

21

10

11

944

8

34

7

24

6

14

542

4

32

3

22

2

12

1

A1

13

A2

14

Zelio Relay - plug-in relaysRXM miniature relays

Dimensions

40 21

27

9 6 2,5 2,521

6,3

6,3

4,2

4,2

13,22,5 2,5 4,4

21

13,2

6,6 6,6

2,5 2,513,2

4,4 4,44,4

1

2

3

4

5

6

7

8

9

10

Page 30: Schneider Electric - Relay's Catalog Sept 09

2

Dimensions (continued)Plastic clamp and clip-in legendsRXZ R335 RXZ L420 Mounting on all sockets (1)

(1) Clip-in legends for all sockets except RXZ E2M114

Bus jumper Metal clampRXZ S2 Mounting on sockets with separate contacts

(view from below)RXZ 400

Example of bus jumper mounting on sockets

(1) 2 bus jumpers (polarity A2)(2) 2 bus jumpers (polarity A1)

Mounting adapter for rails (1) Mounting adapter for panelRXZ E2DA RXZ E2FA

(1) Test button becomes inaccessible

57

27

57

27

12

14,2

26,5

12

14,2

26,5

81

94,5

(1)

81

94,5

(1)

2,2 7,

3

25

22

2,3

2,2 7,

3

25

22

2,3(1)(1)

(2)(2)

(1)(1)

(2)(2)

22

42

0,

22

42

0,

38

6 424

348

23

51

38

6 424

348

23

51

48 49

3,5

43 38

4

24

3,5

48 49

3,5

43 38

4

24

3,5

Presentation :page 22

Characteristics :pages 23 and 24

References :pages 25 and 26

Dimensions :pages 27 and 2

Schemes :page 29

Presentation :page 22

Characteristics :pages 23 and 24

References :pages 25 and 26

Dimensions :pages 27 and 2

Schemes :page 29

Zelio Relay - plug-in relaysRXM miniature relays

Dimensions (continued)

1

2

3

4

5

6

7

8

9

10

Page 31: Schneider Electric - Relay's Catalog Sept 09

29

SchemesMiniature relaysRXM 2ppppp RXM 3ppppp RXM 4ppppp

Symbols shown in blue correspond to Nema marking.

Sockets RXZ E2M114 RXZ E2M114M

347

14A2 A1

13

246

844 14

5

1

119

2110

3111

4112

2312223242

4

448

347

246

145

12312223242

4

14A2 A1

13

14 13

1021

9

9

5

1

111131

1241

Symbols shown in blue correspond to Nema marking.RXZ E2S108M RXZ E2S111M RXZ E2S114M

1241 11

9

844 14

5

A1

13

A2

A1A214

424

121

INPUT

A1

13

A2

A1A214

319

346

3

218

245

2

117

144

32 22 121

INPUT

A1

13

A2

A1A214

4112

3111

2110

119

448

347

246

145

424

323

222

121

INPUT

Symbols shown in blue correspond to Nema marking.Protection modules RXM 040W RXM 041ppp RXM 021ppp

– A2

+ A1

– A2

+ A1

– A2

+ A1

A2

A1

414442

111412

1

125

149

11

4

428

4412

4113

A1

14

A2

A2

A1

414442

111412

1

125

149

11

4

428

4412

4113

A1

14

A2

A2

A1

313432

212422

111412

1

12

4

147

11

2

22

5

248

21

3

32

6

349

3113

A1

14

A2

A2

A1

313432

212422

111412

1

12

4

147

11

2

22

5

248

21

3

32

6

349

3113

A1

14

A2

A2

A1

414442

212422

313432

111412

1

125

149

11

4

428

4412

41

2

226

2410

21

3

327

3411

3113

A1

14

A2

A2

A1

414442

212422

313432

111412

1

125

149

11

4

428

4412

41

2

226

2410

21

3

327

3411

3113

A1

14

A2

Zelio Relay - plug-in relaysRXM miniature relays

Schemes

1

2

3

4

5

6

7

8

9

10

Page 32: Schneider Electric - Relay's Catalog Sept 09

30

Presentation of the range The RUM universal relay range comprises: 1 10 A relays with 2 and 3 C/O contacts, with cylindrical or flat (Faston type) pins,

and 3 A low level relays with 3 C/O contacts, with cylindrical pins. All these relays have the same dimensions.

2 Sockets with mixed or separate contact terminals.3 Protection modules (diode, RC circuit or varistor) or 1 timer module. All these

modules are common to all sockets.4 A metal maintaining clamp for all sockets.5 A 2-pole bus jumper that can be used on sockets with separate contact terminals

in order to simplify cabling when creating an equipotential link between the coil terminals.

6 Clip-in legends for the sockets.

Relay description 1 Spring return pushbutton for testing the contacts (green: c, red: a). 2 Mechanical “relay status” indicator.3 Removable lock-down door enabling forced maintaining of the contacts for test

sequences or maintenance purposes. During operation, this lock-down door must always be in the closed position.

4 LED (depending on version) indicating the relay status.5 Removable legend for relay identification.6 Area by which the product can be easily gripped.7 Eight or eleven cylindrical pins. 8 Eight or eleven flat (Faston type) pins

Socket description Sockets with mixed contact terminals (1)

1 Connection by screw connector. 2 Eight or eleven female contacts for the relay cylindrical pins.3 Location for protection modules or the timer module.4 Locking component for metal maintaining clamp.5 A locating slot for mounting on 5 rail.6 Two fixing holes for panel mounting.

Sockets with separate contact terminals (2)1 Connection by screw connector. 2 a Eight or eleven female contacts for the relay cylindrical pins.

b Eleven female contacts for the relay flat pins.3 Location for protection modules or the timer module.4 Locking component for metal maintaining clamp.5 Locating slot for mounting on 5 rail with fixing clip.6 Two fixing holes for panel mounting.7 Location for bus jumpers (see mounting on sockets on page 36).

(1) The inputs are mixed with the relay's supply, with the outputs being located on the opposite side of the socket.

(2) The inputs and outputs are separated from the relay supply.

5362

94

6

5

2

1

3

4

5362

94

6

5

2

1

3

4

1066

63 12

34

5

6

1066

63 12

34

5

6

1060

22 1

2

3

4

5

6

Outputs

Relay supply

Inputs

Relay suppy

1060

22 1

2

3

4

5

6

Outputs

Relay supply

Inputs

Relay suppy

1060

23 16

2a

3

4

5 7

Inputs

Outputs

Relay supply5

1060

23 16

2a

3

4

5 7

Inputs

Outputs

Relay supply5

1060

24 1

2b

3

4

5 7

Inputs

Outputs

Relay supply5

1060

24 1

2b

3

4

5 7

Inputs

Outputs

Relay supply5

Zelio Relay - plug-in relaysRUM universal relays

Presentation

Characteristics :page 31

References :pages 33 and 34

Dimensions :page 35

Schemes :page 37

Setting-up :page 39

Characteristics :page 31

References :pages 33 and 34

Dimensions :page 35

Schemes :page 37

Setting-up :page 39

1

2

3

4

5

6

7

8

9

10

Page 33: Schneider Electric - Relay's Catalog Sept 09

31

General characteristicsConforming to standards IEC/EN 6110-1 (iss. 2), UL 50, CSA C22-2 n° 14Product certifications UL, CSAAmbient air temperature around the device

Storage °C - 40… + 5Operation °C - 40… + 55

Vibration resistanceconforming to IEC/EN 6006-2-6

In operation 3 gn (10...150 Hz/± 1 mm / 5g/5 cycles)Not operating 4 gn (10...150 Hz/± 1 mm / 5g/5 cycles)

Degree of protection Conforming to IEC/EN 60529 IP 40Shock resistanceconforming to IEC/EN 6006-2-27

Opening 10 gnClosing 10 gn

Protection category RT IMounting position Any

Insulation characteristicsRated insulation voltage (Ui) Conforming to IEC/EN 60947 V 250 (IEC), 300 (UL, CSA)Rated impulse withstand voltage (Uimp) kV 4 (1.2/50 ms)Dielectric strength(rms voltage)

Between coil and contact a V 1550Between poles a V 1550Between contacts a V 1500

Contact characteristicsRelay type RUM F2ppp RUM F3ppp RUM C2ppp RUM C3App RUM C3Gpp

Number and type of contacts 2 C/O 3 C/O 2 C/O 3 C/O 3 C/O low levelContact materials . AgNi AgAuConventional thermal current (Ith)

For ambient temperature y 55°C

A 10 3

Rated operational current in utilisation categories AC-1 and DC-1

Conforming to IEC "C" A 10 2“O” A 5 1

Conforming to UL A 16 / a 277 V 12 / c 2 V

3

Switching current Minimum mA 10 3Switching voltage Maximum V a/c 250 (IEC)

Minimum V 17 5Nominal load (resistive) A 10 / 250 a V 3 / 250 a V

A 10 / 2 c V 3 / 2 c VSwitching capacity Maximum a VA 2500 750

c W 20 4Minimum mW 170 15

Maximum operating rateIn operating cycles/hour

No-load 1 000Under load 1200

Utilisation coefficient 20 %Mechanical durability In millions of operating cycles 5Electrical durability In millions of operating cycles

Resistive load 0.1Inductive load See curves below

Electrical durability of contactsResistive load a

Reduction coefficient for inductive load a (depending on power factor cos j)

Maximum switching capacity on resistive load c

A RUM Fppppp, RUM C2ppp, RUM C3Appp B RUM C3Gppp

Durability (inductive load) = durability (resistive load) x reduction coefficient.

105

106

107

2 30 1

AB

Dur

abili

ty (N

umbe

r of o

pera

ting

cycl

es)

Switching capacity (kVA)

105

106

107

2 30 1

AB

Dur

abili

ty (N

umbe

r of o

pera

ting

cycl

es)

Switching capacity (kVA)

0,3

0,5

0,61 0,4 0,2

0,4

0,60,

1

Red

uctio

n c

oeffi

cien

t (A

)

0,3

0,5

0,61 0,4 0,2

0,4

0,60,

1

Red

uctio

n c

oeffi

cien

t (A

)

0,1

1

200 2500 50 100 150

10

3

B A

28

Cur

rent

c

Voltage c

0,1

1

200 2500 50 100 150

10

3

B A

28

Cur

rent

c

Voltage c

Zelio Relay - plug-in relaysRUM universal relays

Characteristics

1

2

3

4

5

6

7

8

9

10

Page 34: Schneider Electric - Relay's Catalog Sept 09

32

Coil characteristicsAverage consumption a VA 2...3

c W 1.4Drop-out voltage threshold a u 0.15 Uc

c u 0.1 UcOperating time(response time)

Between coil energisation and making of the On-delay contact

a ms 20c ms 20

Between coil de-energisation and making of the Off-delay contact

a ms 20c ms 20

Control circuit voltage Uc V 12 24 48 60 110 120 125 220 230Relay control voltage codes JD BD ED ND FD – GD MD –

d.c. supply Average resistance at 20 °C ± 10% W 120 470 100 2790 10 000 – 10 000 3700 –Operating voltage limits

Min. V 9.6 19.2 3.4 4 – 100 176 –Max. V 13.2 26.4 52. 66 121 – 137.5 242 –

Relay control voltage codes – B7 E7 – – F7 – – P7a.c. supply Average resistance at 20 °C ± 15% W – 72 290 – – 1700 – – 7200

Operating voltage limits

Min. V – 19.2 3.4 – – 96 – – 14Max. V – 26.4 52. – – 132 – – 253

Socket characteristicsSocket type RUZ C2M RUZ C3M RUZ SC2M RUZ SC3M RUZ SF3MRelay types used RUM C2ppppp RUM C3ppppp RUM C2ppppp RUM C3ppppp RUM Fppppp

Contact terminal arrangement Mixed SeparateWire connection method ConnectorProduct certifications UL, CSA Conforming to standards IEC 6194, e

Electrical characteristicsConventional thermal current (Ith) A 10 12Maximum operating voltage V 250 (IEC)

Insulation characteristicsBetween adjacent output contacts Vrms 2500Between input and output contacts Vrms 2500Between contacts and 5 rail Vrms 2500

General characteristicsAmbient air temperaturearound the device

Operation °C - 40…+ 55Storage °C - 40…+ 5

Degree of protection Conforming to IEC/EN 60529 IP 20Cabling Solid cable

without cable end

1 conductor 0.5…2.5 mm2 - AWG 20…AWG 142 conductors 0.5…1.5 mm2 - AWG 20…AWG 16

Flexible cable with cable end

1 conductor 0.25…2.5 mm2 - AWG 22…AWG 142 conductors 0.25…1 mm2 - AWG 22…AWG 17

Maximum tightening torque / Screw size Nm 1 / M3.3 screwMounting On 35 mm 5 rail / on panelFixing on 5 rail By red plastic clipTerminal referencing IEC, NEMABus jumper (Ith: 5 A) No YesCompatibility with the metal maintaining clamp YesTimer module YesProtection module All RUW 24ppp

Clip-in legends No YesWire connection method Screw connector

Zelio Relay - plug-in relaysRUM universal relays

Characteristics (continued)

Characteristics :page 31

References :pages 33 and 34

Dimensions :page 35

Schemes :page 37

Setting-up :page 39

Characteristics :page 31

References :pages 33 and 34

Dimensions :page 35

Schemes :page 37

Setting-up :page 39

1

2

3

4

5

6

7

8

9

10

Page 35: Schneider Electric - Relay's Catalog Sept 09

33

ReferencesRelays for standard applications, without LED (sold in lots of 10)Pins Control

circuit voltageNumber and type of contacts - Thermal current (Ith)2 C/O - 10 A 3 C/O - 10 AUnit reference

Weight Unit reference

Weight

V kg kgCylindrical c 12 RUM C2AB1JD 0.05 RUM C3AB1JD 0.0

c 24 RUM C2AB1BD 0.05 RUM C3AB1BD 0.0c 4 RUM C2AB1ED 0.05 RUM C3AB1ED 0.0c 60 – – RUM C3AB1ND 0.0c 110 RUM C2AB1FD 0.05 RUM C3AB1FD 0.0c 125 – – RUM C3AB1GD 0.0c 220 – – RUM C3AB1MD 0.0

a 24 RUM C2AB1B7 0.05 RUM C3AB1B7 0.0a 4 RUM C2AB1E7 0.05 RUM C3AB1E7 0.0a 120 RUM C2AB1F7 0.05 RUM C3AB1F7 0.0a 230 RUM C2AB1P7 0.05 RUM C3AB1P7 0.0

Flat (Faston type) c 12 RUM F2AB1JD 0.00 RUM F3AB1JD 0.02c 24 RUM F2AB1BD 0.00 RUM F3AB1BD 0.02c 4 RUM F2AB1ED 0.00 RUM F3AB1ED 0.02c 110 RUM F2AB1FD 0.00 RUM F3AB1FD 0.02

a 24 RUM F2AB1B7 0.00 RUM F3AB1B7 0.02a 4 RUM F2AB1E7 0.00 RUM F3AB1E7 0.02a 120 RUM F2AB1F7 0.00 RUM F3AB1F7 0.02a 230 RUM F2AB1P7 0.00 RUM F3AB1P7 0.02

Relays for standard applications, with LED (sold in lots of 10)Cylindrical c 12 RUM C2AB2JD 0.05 RUM C3AB2JD 0.0

c 24 RUM C2AB2BD 0.05 RUM C3AB2BD 0.0c 4 RUM C2AB2ED 0.05 RUM C3AB2ED 0.0c 60 – – RUM C3AB2ND 0.0c 110 RUM C2AB2FD 0.05 RUM C3AB2FD 0.0c 125 – – RUM C3AB2GD 0.0

a 24 RUM C2AB2B7 0.05 RUM C3AB2B7 0.0a 4 RUM C2AB2E7 0.05 RUM C3AB2E7 0.0a 120 RUM C2AB2F7 0.05 RUM C3AB2F7 0.0a 230 RUM C2AB2P7 0.05 RUM C3AB2P7 0.0

Flat (Faston type) c 12 RUM F2AB2JD 0.04 RUM F3AB2JD 0.02c 24 RUM F2AB2BD 0.04 RUM F3AB2BD 0.02c 4 RUM F2AB2ED 0.04 RUM F3AB2ED 0.02c 110 RUM F2AB2FD 0.04 RUM F3AB2FD 0.02

a 24 RUM F2AB2B7 0.04 RUM F3AB2B7 0.02a 4 RUM F2AB2E7 0.04 RUM F3AB2E7 0.02a 120 RUM F2AB2F7 0.04 RUM F3AB2F7 0.02a 230 RUM F2AB2P7 0.04 RUM F3AB2P7 0.02

Relays with low level contacts, with LED (sold in lots of 10)Pins Control

circuit voltageNumber and type of contacts Thermal current (Ith)3 C/O - 3 AUnit reference

Weight

V kgCylindrical c 24 RUM C3GB2BD 0.06

c 4 RUM C3GB2ED 0.06

a 24 RUM C3GB2B7 0.06a 4 RUM C3GB2E7 0.06a 120 RUM C3GB2F7 0.06a 230 RUM C3GB2P7 0.06

Zelio Relay - plug-in relaysRUM universal relays

References

RUM ppAB1F7

1066

64

RUM ppAB2F7

1066

63

1

2

3

4

5

6

7

8

9

10

Page 36: Schneider Electric - Relay's Catalog Sept 09

34

References (continued)SocketsContact terminal arrangement

Connection Relay type Sold in lots of

Unit reference

Weightkg

Mixed Screw connector RUM C2ppppp 10 RUZ C2M 0.054RUM C3ppppp 10 RUZ C3M 0.054

Separate Screw connector RUM C2ppppp 10 RUZ SC2M 0.095RUM C3ppppp 10 RUZ SC3M 0.100RUM F2pppp 10 RUZ SF3M 0.095RUM F3pppp

Protection modulesDescription For

use withVoltage Sold in

lots ofUnit reference

Weight

V kgDiode All sockets c 6…250 10 RUW 240BD 0.004

RC circuit All sockets a 110…240 10 RUW 241P7 0.004

Varistor All sockets a/c 24 10 RUW 242B7 0.004a/c 240 10 RUW 242P7 0.004

Timer moduleDescription For

use withVoltage Reference Weight

V kgMultifunction All sockets a/c 24… 240 RUW 101MW 0.020

Timing relaysDescription For

use withReference Weight

kg2 timed C/O contacts (single-function or multifunction)

On sockets RUZ CpM RE 48A pp (1)

AccessoriesDescription For

use withSold in lots of

Unit reference

Weightkg

Metal maintaining clamp All sockets 10 RUZC200 0.001

Bus jumper 2-pole (Ith : 5 A) All sockets with separate contacts 10 RUZ S2 0.005

Clip-in legends All relays(sheet of 10 legends)

10 RXZ L520 0.00

All sockets with separate contacts 10 RUZ L420 0.001

(1) Please consult the "Zelio Time timing relays" catalogue.

Zelio Relay - plug-in relaysRUM universal relays

References (continued)

Characteristics :page 31

References :pages 33 and 34

Dimensions :page 35

Schemes :page 37

Setting-up :page 39

Characteristics :page 31

References :pages 33 and 34

Dimensions :page 35

Schemes :page 37

Setting-up :page 39

RUZ C200

5364

5

RUW 101MW

106

02

RUW 241P7

1060

27

RUZ C3M + relais RUM C3ppppp

1060

25

RUZ S2

5352

03

1

2

3

4

5

6

7

8

9

10

Page 37: Schneider Electric - Relay's Catalog Sept 09

35

DimensionsUniversal relaysRUM Cpp RUM Fpp

SocketsCommon side view RUZ C2M RUZ C3M

38

37

30

24

6

27

A2

7

A1

2

11

1

21

8

A2

7

INPUT A2INPUT A1

22

5

12

4

1

4

2

3

8

5

7

6

14

3

38

37

30

A2

10

A2

10

31

11

21

6

11

1

A1

2

34

9

32

8

24

7

22

5

14

3

12

4

210

1

6

2

5

3

4

1110

7

9

8

INPUT A2INPUT A1

RUZ SC2M RUZ SC3M

(1) Relays(2) Protection module(3) Maintaining clamp(4) 2 bus jumpers

55 35

35

9 55 35

35

9

35

35539

35

35539

74

27

22

6389

93

(1)(3)

(2)

474

27

22

6389

93

(1)(3)

(2)

4

3675

102

105

29

924

40

30

19

45

225

111

124

246

1

4

2

3

8

5

7

6

A27

A12

218

143

Ø 4

(4)

(1)(3)

(2)

3675

102

105

29

924

40

30

19

45

225

111

124

246

1

4

2

3

8

5

7

6

A27

A12

218

143

Ø 4

(4)

(1)(3)

(2)

3675

102

105

29

924

40

32

63

3111

216

111

32

8

22

5

12

4

349

21

5

34

11

7 6

1098

A210

A12

247

143

Ø 4(1)(3)

(2)

19

(4)

3675

102

105

29

924

40

32

63

3111

216

111

32

8

22

5

12

4

349

21

5

34

11

7 6

1098

A210

A12

247

143

Ø 4(1)(3)

(2)

19

(4)

Zelio Relay - plug-in relaysRUM universal relays

Dimensions

1

2

3

4

5

6

7

8

9

10

Page 38: Schneider Electric - Relay's Catalog Sept 09

36

Dimensions (continued)Sockets (continued)RUZ SF3M

36104

294627

924

63

219

318

117

223

322

121

246

A2B

A1A

345

144

(1)

(3)

(2)

(4)

(1) Relays(2) Protection module(3) Maintaining clamp(4) 2 bus jumpersMetal maintaining clamps and plastic legendsRUZ C200 Mounting

0,

59,6

35

108

RUZ L420

12

14,2

32

Bus jumperRUZ S2 Mounting on sockets with separate contacts (view from below)

Example of bus jumper mounting on sockets

(2)(2)

(1)(1)

(1) 2 bus jumpers (polarity A2)(2) 2 bus jumpers (polarity A1)

3,3

8,5

35,4

322,3

3,3

8,5

35,4

322,3

Dimensions (continued) Zelio Relay - plug-in relaysRUM universal relays

Characteristics :page 31

References :pages 33 and 34

Dimensions :page 35

Schemes :page 37

Setting-up :page 39

Characteristics :page 31

References :pages 33 and 34

Dimensions :page 35

Schemes :page 37

Setting-up :page 39

1

2

3

4

5

6

7

8

9

10

Page 39: Schneider Electric - Relay's Catalog Sept 09

37

Schemes Zelio Relay - plug-in relaysRUM universal relays

SchemesUniversal relaysRUM p2ABppp RUM C3ppppp RUM F3ABppp

RUM C2ABppp RUM F2ABppp RUM C3ppppp RUM F3ABppp

Symbols shown in blue correspond to Nema marking.SocketsRUZ C2M RUZ C3M RUZ SC2M RUZ SC3M

24

6

A27

A12

111

218

A27

22

5

12

4

1

4

2

3

8

5

7

6

14

3

32

8

34

9

A210

A12

111

3111

216

A210

24

7

22

5

14

3

12

4

1

6

2

5

34

1110

7

98

225

111

124

624 8

21

314

A27

A12

1

4

2

3

8

5

7

6

3111

216

111

328

225

124

349

247

143

1

6

2

5

34

1110

7

98

A210

A12

Symbols shown in blue correspond to Nema marking.

RUZ SF3M

219

318

117

223

322

121

246

345

144

A2B

A1A

Symbols shown in blue correspond to Nema marking.

1211

14 2221

24 A2

A1

1211

14 2221

24 A2

A1

1211

14 2221

24 3231

34 A2

A1

1211

14 2221

24 3231

34 A2

A1

1211

14 2221

243231

34 A2

A1

1211

14 2221

243231

34 A2

A1

3

7

1

6

2

4 5

A1 A2

2111

14 24

2212

+

3

7

1

6

2

4 5

A1 A2

2111

14 24

2212

+

1

124

147

11

3

226

249

21A

A1

B

A2(+) ( )

1

124

147

11

3

226

249

21A

A1

B

A2(+) ( )

4

3 9

2

1 11

10

56

7

A1 A2

14 34

3111

12 32

22 2421

+

4

3 9

2

1 11

10

56

7

A1 A2

14 34

3111

12 32

22 2421

+

(+)

1

124

147

11

2

325

34

31

3

226

249

21A

A1

B

A2( )(+)

1

124

147

11

2

325

34

31

3

226

249

21A

A1

B

A2( )

1

2

3

4

5

6

7

8

9

10

Page 40: Schneider Electric - Relay's Catalog Sept 09

3

Schemes (continued)Protection modulesRUW 240BD RUW 241P7 RUW 242pp

– A2

+ A1

– A2

+ A1

– A2

+ A1

Zelio Relay - plug-in relaysRUM universal relays

Schemes (continued)

Characteristics :page 31

References :pages 33 and 34

Dimensions :page 35

Schemes :page 37

Setting-up :page 39

Characteristics :page 31

References :pages 33 and 34

Dimensions :page 35

Schemes :page 37

Setting-up :page 39

1

2

3

4

5

6

7

8

9

10

Page 41: Schneider Electric - Relay's Catalog Sept 09

39

Multifunction timer module RUW 101MWProgramming Timing range selection

Function selectionSelection Function Control Function diagram Control scheme

On-delay TimerE

Series control

Monostable with maintained controlWu

Series control

Flashing relay, starting On-delay phaseBi

Series control

Flashing relay, starting Off-delay phaseBp

Series control

Off-delay timerR

Control by external contact (S)

Monostable with pulse controlWs

Control by external contact (S)

Monostable, starting on de-energisationWa

Control by external contact (S)

On-delay TimerEs

Control by external contact (S)

Power off Contact open U : voltage S : external control

Power on Contact closed R : relay RUM ppp t : adjustable time delay

Functionselection

Timing rangeselection

0.1…1 s 0.1…10 s 0.1…1 min 1…10 min 0.1…1 h 1…10 h 0.1…1 day 1…10 days

Functionselection

Timing rangeselection

0.1…1 s 0.1…10 s 0.1…1 min 1…10 min 0.1…1 h 1…10 h 0.1…1 day 1…10 days

t

U

.1/.4

.1/.2t

U

.1/.4

.1/.2 A1

A2

U

R

A1

A2

U

RU

.1/.4

.1/.2t

U

.1/.4

.1/.2t

U

.1/.4

.1/.2t t

U

.1/.4

.1/.2t t

U

.1/.4

.1/.2t t

U

.1/.4

.1/.2t t

S

U

.1/.4

.1/.2t

S

U

.1/.4

.1/.2t

B1

A1

A2

U

R

S

B1

A1

A2

U

R

S

S

U

.1/.4

.1/.2t

S

U

.1/.4

.1/.2t

S

U

.1/.4

.1/.2t

S

U

.1/.4

.1/.2t

S

U

.1/.4

.1/.2t

S

U

.1/.4

.1/.2t

Zelio Relay - plug-in relaysRUM universal relays

Setting-up

1

2

3

4

5

6

7

8

9

10

Page 42: Schneider Electric - Relay's Catalog Sept 09

40

9

7

1066

73

Presentation of the range The RPM power relay range comprises: 1 15 A relays with 1, 2, 3 and 4 C/O contacts.2 Sockets with mixed contact terminals.3 Protection modules (diode, RC circuit or varistor) or 1 timer module. All these

modules are common to all the sockets except for the timer module, which can only be used on the 3-pole or 4-pole sockets.

A metal maintaining clamp for single-contact relays.

Relay description 1 Spring return pushbutton for testing the contacts (green: c, red: a). 2 Mechanical “relay status” indicator.3 Removable lock-down door enabling forced maintaining of the contacts for test

sequences or maintenance purposes. During operation, this lock-down door must always be in the closed position.

4 LED (depending on version) indicating the relay status.5 Removable legend for relay identification.6 Four notches for rail mounting adapter or panel mounting adapter with fixing lugs.7 Five, eight, eleven or fourteen Faston type pins.8 Area by which the product can be easily gripped.9 Mounting adapter enabling direct mounting of the relay on a panel.10 Mounting adapter enabling direct mounting of the relay on a 5 rail.

Socket descriptionSockets with mixed contact terminals (1)

1 Connection by screw clamp terminals. 2 Five, eight, eleven or fourteen female contacts for the relay pins.3 Location for protection modules or the timer module.4 Locating slot for mounting on rail with fixing clip.5 Two or four fixing holes for panel mounting.

(1) The inputs are mixed with the relay's supply, with the outputs being located on the opposite side of the socket.

Zelio Relay - plug-in relays RPM power relays

1060

35

2

1

3

1066

69

2

7

3

56

8

4

1

1066

72 9

1066

74

10

1060

40 1

5

2

3

Outputs

4 Inputs

Relay supply

Characteristics :page 41

References :page 43

Dimensions :page45

Schemes :page 47

Characteristics :page 41

References :page 43

Dimensions :page45

Schemes :page 47

Presentation

1

2

3

4

5

6

7

8

9

10

Page 43: Schneider Electric - Relay's Catalog Sept 09

41

General characteristicsConforming to standards IEC/EN 6110-1 (iss. 2), UL 50, CSA C22-2 n° 14Product certifications UL, CSAAmbient air temperature around the device

Storage °C - 40… + 5Operation °C - 40… + 55

Vibration resistanceconforming to IEC/EN 6006-2-6

In operation 3 gn (10...150 Hz/± 1 mm / 5g/5 cycles)Not operating 5 gn (10...150 Hz/± 1 mm / 5g/5 cycles)

Degree of protection Conforming to IEC/EN 60529 IP 40Shock resistanceconforming to IEC/EN 6006-2-27

Opening 15 gnClosing 15 gn

Protection category RT IMounting position Any

Insulation characteristicsRated insulation voltage (Ui) Conforming to IEC/EN 60947 V 250 (IEC), 300 (UL, CSA)Rated impulse withstand voltage (Uimp) kV 4 (1.2/50 ms)Dielectric strength(rms voltage)

Between coil and contact a V 1550Between poles a V 1550Between contacts a V 1500

Contact characteristicsRelay type RPM 1ppp RPM 2ppp RPM 3ppp RPM 4ppp

Number and type of contacts 1 C/O 2 C/O 3 C/O 4 C/OContact materials AgNiConventional thermal current (Ith)

For ambient temperature y 55 °C

A 15

Rated operational current in utilisation categories AC-1 and DC-1

Conforming to IEC "C" A 15“O” A 7.5

Conforming to UL A 15Switching current Minimum mA 10Switching voltage Maximum V a/c 250 (IEC)

Minimum V 17Nominal load (resistive) A 15 / 250 a V

A 15 / 2 c VSwitching capacity Maximum a VA 3750

c W 420Minimum mW 170

Maximum operating rateIn operating cycles/hour

No-load 1 000Under load 1200

Utilisation coefficient 20 %Mechanical durability In millions of

operating cycles10

Electrical durability In millions of operating cycles

Resistive load 0.1 0.06Inductive load See curves below

Electrical durability of contactsResistive load a

Reduction coefficient for inductive load a (depending on power factor cos j)

Maximum switching capacity on resistive load c

Durability (inductive load) = durability (resistive load) x reduction coefficient.

10520 1 43

3,75

106

107

Dur

abili

ty (N

umbe

r of o

pera

ting

cycl

es)

Switching capacity (kVA)

10520 1 43

3,75

106

107

Dur

abili

ty (N

umbe

r of o

pera

ting

cycl

es)

Switching capacity (kVA)

0,3

0,5

0,61 0,4 0,2

0,4

0,60,

1

Red

uctio

n co

effic

ient

(A)

0,3

0,5

0,61 0,4 0,2

0,4

0,60,

1

Red

uctio

n co

effic

ient

(A)

0,1

1

200 2500 50 100 150

1015

28

Cur

rent

c

Voltage c

0,1

1

200 2500 50 100 150

1015

28

Cur

rent

c

Voltage c

Characteristics Zelio Relay - plug-in relays RPM power relays

1

2

3

4

5

6

7

8

9

10

Page 44: Schneider Electric - Relay's Catalog Sept 09

42

Coil characteristicsRelay type RPM 1ppp RPM 2ppp RPM 3ppp RPM 4ppp

Average consumption a VA 0.9 1.2 1.5 1.5c W 0.7 0.9 1.7 2

Drop-out voltage threshold a u 0.15 Ucc u 0.1 Uc

Operating time(response time)

Between coil energisation and making of the On-delay contact

a ms 20 25 25 20

c ms 20 25 25 20

Between coil de-energisation and making of the Off-delay contact

a ms 20

c ms 20

Control circuit voltage Uc V 12 24 48 110 120 230Relay control voltage codes JD BD ED FD – –

d.c. supply Average resistance at 20 °C ± 10%

RPM 1ppp W 10 750 2600 13 100 – –RPM 2ppp W 160 650 2600 11 000 – –RPM 3ppp W 100 400 2600 600 – –RPM 4ppp W 96 3 1550 7340 – –

Operating voltage limits

Min. V 9.6 19.2 3.4 – –Max. V 13.2 26.4 52. 121 – –

Relay control voltage codes – B7 E7 – F7 P7a.c. supply Average resistance

at 20 °C ± 15%RPM 1ppp W – 160 720 – 4430 15 720RPM 2ppp W – 10 770 – 4430 15 000RPM 3ppp W – 103 770 – 2770 12 000RPM 4ppp W – 4.3 33 – 2220 9120

Operating voltage limits

Min. V – 19.2 3.4 – 96 14Max. V – 26.4 52. – 132 253

Socket characteristicsSocket type RPZ F1 RPZ F2 RPZ F3 RPZ F4Relay types used RPM 1ppp RPM 2ppp RPM 3ppp RPM 4ppp

Protection module types used RXM 02pppRXM 04ppp

RXM 02pppRXM 04ppp

RUW 24ppp RUW 24ppp

Contact terminal arrangement MixedWire connection method Screw clamp terminalsProduct certifications UL, CSA Conforming to standards IEC 6194, e

Electrical characteristicsConventional thermal current (Ith) A 16Maximum operating voltage V 250 (IEC)

Insulation characteristicsBetween adjacent output contacts Vrms 2500Between input and output contacts Vrms 2500Between contacts and 5 rail Vrms 2500

General characteristicsAmbient air temperaturearound the device

Operation °C - 40…+ 55Storage °C - 40…+ 5

Degree of protection Conforming to IEC/EN 60529 IP 20Cabling Solid cable

without cable end

1 conductor 0.5…1.5 mm2 - AWG 20…AWG 16 0.5…2.5 mm2 - AWG 20…AWG 142 conductors 0.5…1.5 mm2 - AWG 20…AWG 16 0.5…2.5 mm2 - AWG 20…AWG 14

Flexible cable with cable end

1 conductor 0.25…1 mm2 - AWG 22…AWG 17 0.25…1.5 mm2 - AWG 22…AWG 162 conductors 0.25…1 mm2 - AWG 22…AWG 17 0.25…1.5 mm2 - AWG 22…AWG 16

Maximum tightening torque / Screw size Nm 1 / M3 screw 1 / M3.5 screwMounting On 35 mm 5 rail / on panelFixing on 5 rail By red plastic clipTerminal referencing IEC, NEMACompatibility with the metal maintaining clamp Yes NoTimer module No YesProtection module RXM 040W, RXM 041pp, RXM 021pp RUW 24pp

Clip-in legends NoWire connection method Screw clamp terminals

Characteristics (continued) Zelio Relay - plug-in relays RPM power relays

Presentation :page 40

Characteristics :page 41

References :page 43

Dimensions :page 45

Schemes :page 47

Presentation :page 40

Characteristics :page 41

References :page 43

Dimensions :page 45

Schemes :page 47

1

2

3

4

5

6

7

8

9

10

Page 45: Schneider Electric - Relay's Catalog Sept 09

43

Power relays without LED (sold in lots of 10)Control circuit voltge

Number and type of contacts - Thermal current (Ith)1 C/O - 15 A 2 C/O - 15 A 3 C/O - 15 A 4 C/O - 15 AUnit reference

Weight Unit reference

Weight Unit reference

Weight Unit reference

Weight

V kg kg kg kgc 12 RPM 11JD 0.026 RPM 21JD 0.036 RPM 31JD 0.054 RPM 41JD 0.071

c 24 RPM 11BD 0.026 RPM 21BD 0.036 RPM 31BD 0.054 RPM 41BD 0.071

c 4 RPM 11ED 0.026 RPM 21ED 0.036 RPM 31ED 0.054 RPM 41ED 0.071

c 110 RPM 11FD 0.026 RPM 21FD 0.036 RPM 31FD 0.054 RPM 41FD 0.071

a 24 RPM 11B7 0.026 RPM 21B7 0.036 RPM 31B7 0.054 RPM 41B7 0.071

a 4 RPM 11E7 0.026 RPM 21E7 0.036 RPM 31E7 0.054 RPM 41E7 0.071

a 120 RPM 11F7 0.026 RPM 21F7 0.036 RPM 31F7 0.054 RPM 41F7 0.071

a 230 RPM 11P7 0.026 RPM 21P7 0.036 RPM 31P7 0.054 RPM 41P7 0.071

Power relays with LED (sold in lots of 10)c 12 RPM 12JD 0.026 RPM 22JD 0.036 RPM 32JD 0.054 RPM 42JD 0.071

c 24 RPM 12BD 0.026 RPM 22BD 0.036 RPM 32BD 0.054 RPM 42BD 0.071

c 4 RPM 12ED 0.026 RPM 22ED 0.036 RPM 32ED 0.054 RPM 42ED 0.071

c 110 RPM 12FD 0.026 RPM 22FD 0.036 RPM 32FD 0.054 RPM 42FD 0.071

a 24 RPM 12B7 0.026 RPM 22B7 0.036 RPM 32B7 0.054 RPM 42B7 0.071

a 4 RPM 12E7 0.026 RPM 22E7 0.036 RPM 32E7 0.054 RPM 42E7 0.071

a 120 RPM 12F7 0.026 RPM 22F7 0.036 RPM 32F7 0.054 RPM 42F7 0.071

a 230 RPM 12P7 0.026 RPM 22P7 0.036 RPM 32P7 0.054 RPM 42P7 0.071

References Zelio Relay - plug-in relays RPM power relays

RPM 41BD

1066

70

RPM 42BD

1066

69

1

2

3

4

5

6

7

8

9

10

Page 46: Schneider Electric - Relay's Catalog Sept 09

44

SocketsContact terminal arrangement

Connection Relay type Sold in lots of

Unit reference

Weightkg

Mixed Screw clamp terminals

RPM 1ppp 10 RPZ F1 0.042RPM 2ppp 10 RPZ F2 0.054RPM 3ppp 10 RPZ F3 0.072

RPM 4ppp 10 RPZ F4 0.094

Protection modulesDescription Voltage Socket type Sold in

lots ofUnit reference

Weight

V kgDiode c 6...250 RPZ F1RPZ F2 20 RXM 040W 0.003

RPZ F3RPZ F4

10 RUW 240BD 0.004

RC circuit a 24...60 RPZ F1RPZ F2 20 RXM 041BN7 0.010

a 110...240 RPZ F1RPZ F2 20 RXM 041FU7 0.010

RPZ F3RPZ F4

10 RUW 241P7 0.004

Varistor a/c 6...24 RPZ F1RPZ F2 20 RXM 021RB 0.030

a/c 24...60 RPZ F1RPZ F2 20 RXM 021BN 0.030

a/c 110...240 RPZ F1RPZ F2 20 RXM 021FP 0.030

a/c 24 RPZ F3RPZ F4

10 RUW 242B7 0.004

a/c 240 RPZ F3RPZ F4

10 RUW 242P7 0.004

Timer module (1)Description Voltage Socket type Reference Weight

V kgMultifunction a/c 24… 240 RPZ F3

RPZ F4RUW 101MW 0.020

AccessoriesDescription For

use withSold in lots of

Unit reference

Weightkg

Metal maintaining clamp(for single-pole relays)

RPZ F1 20 RPZ R235 0.001

Mounting adapters for 5 rail (2) RPM 1ppp 20 RPZ 1DA 0.004RPM 2ppp 20 RXZ E2DA 0.004RPM 3ppp 20 RPZ 3DA 0.004RPM 4ppp 20 RPZ 4DA 0.006

Mounting adapters with fixing lugs for panel RPM 1ppp 20 RPZ 1FA 0.002RPM 2ppp 20 RXZ E2FA 0.002RPM 3ppp 20 RPZ 3FA 0.003RPM 4ppp 20 RPZ 4FA 0.004

Clip-in legends(sheet of 10 legends)

All relays 10 RXZ L520 0.00

(1) See timer module description (selection of functions and time delays) on page 39.(2) Test button becomes inaccessible.

References (continued) Zelio Relay - plug-in relays RPM power relays

Presentation :page 40

Characteristics :page 41

References :page 43

Dimensions :page 45

Schemes :page 47

Presentation :page 40

Characteristics :page 41

References :page 43

Dimensions :page 45

Schemes :page 47

RPZ F2 + relay RPM 22F7

1060

43

RUW 24ppp

1060

44

RPZ 1DA

1060

45

RPZ 3FA

1060

46

1

2

3

4

5

6

7

8

9

10

Page 47: Schneider Electric - Relay's Catalog Sept 09

45

DimensionsPower relaysRPM 1

Common side view RPM2 RPM 3 RPM 4

SocketsRPZ F1 RPZ F2

14

5

12

1

A2

14

A1

13

11

9

31

19

1721

4

71

(1)

(3) (2)

80

40

804

40

44

8

14

5

424

121

A214

A113

41

12

11

9

30 2619

30

4040

4

19

8

76

80 68

4

Ø4,5 x 6

Ø4,5 x 6

(1)

(2)

Common side view RPZ F3 RPZ F4

30

76

804

19

8

(1)

(2)

28

4037

4040

68 4

44

8

24

6

14

542

4

A214

A113

41

12

21

10

11

9

22

2

12

1

Ø4,5 x 6

Ø4,5 x 6364650

4040

68 4

14

5

24

6

34

7

44

8

A2

14

A1

13

41

12

31

11

21

10

11

9

12

1

22

2

32

3

42

4

Ø4,5 x 6

Ø4,5 x 6

(1) Relays(2) Protection module(3) Maintaining clamp

8 39 7

7,1

64,6

44,

68 39 7

7,1

64,6

44,

6 3127

1010

4,6 4,6 4,6

3127

1010

4,6 4,6 4,6

41 1010 10

27

4,6 4,6 4,6 4,6

41 1010 10

27

4,6 4,6 4,6 4,6

Dimensions Zelio Relay - plug-in relays RPM power relays

763 14

40

27

4,7

6,5

65

3,5

2,62,6

27

21 1014,2

4,6 4,6

1

2

3

4

5

6

7

8

9

10

Page 48: Schneider Electric - Relay's Catalog Sept 09

46

Dimensions (continued)Mounting adapters for 5 railRPZ 1DA RXZ E2DA RPZ 3DA RPZ 4DA

Mounting adapters with fixing lugs for panelRPZ 1FA RXZ E2FA RPZ 3FA RPZ 4FA

MountingMounting adapters for 5 rail (1) Mounting adapters with fixing lugs for panel

(1) Test button becomes inaccessible

23 24

49,5

2,523 24

49,5

2,5

384

24

23

483

384

24

23

483 3423

502,

5 3423

502,

5

4420

502,

5 4420

502,

5

3843

3,5 5

16,516

3843

3,5 5

16,516

38

3,5 4

19

43

24

38

3,5 4

19

43

24

38

19

3,5 4

43

34

38

19

3,5 4

43

34

16 3,5 4

3843

44

16 3,5 4

3843

44

Dimensions (continued) Zelio Relay - plug-in relays RPM power relays

Presentation :page 40

Characteristics :page 41

References :page 43

Dimensions :page 45

Schemes :page 47

Presentation :page 40

Characteristics :page 41

References :page 43

Dimensions :page 45

Schemes :page 47

1

2

3

4

5

6

7

8

9

10

Page 49: Schneider Electric - Relay's Catalog Sept 09

47

SchemesPower relaysRPM 1ppp RPM 2ppp RPM 3ppp RPM 4ppp

Symbols shown in blue correspond to Nema marking.

Sockets RPZ F1 RPZ F2 RPZ F3 RPZ F4

145

121

119

A214

A113

INPUT

448

145

424

121

4112A214

119

A113

4112

2110

119

A214

A113

448

246

145

424

222

121

A214

A113

4112

3111

2110

119

448

347

246

145

424

323

222

121

Symbols shown in blue correspond to Nema marking.

Protection modules RXM 040W, RUW 240BD RXM 041ppp, RUW 241P7 RXM 021ppp, RUW 242pp

– A2

+ A1

– A2

+ A1

– A2

+ A1

1

12

5

14

9

1113

A1

14

A2

(+) ( )

A2

A1

111412

1

12

5

14

9

1113

A1

14

A2

(+) ( )

A2

A1

111412

1

125

149

11

4

228

2412

2113

A1

14

A2

(+) ( )

A2

A1

212422

111412

1

125

149

11

4

228

2412

2113

A1

14

A2

(+) ( )

A2

A1

212422

111412

1

12

5

14

9

11

2

22

6

24

10

21

4

42

8

44

12

4113

A1

14

A2

(+) ( )

A2

A1

212422

414442

111412

1

12

5

14

9

11

2

22

6

24

10

21

4

42

8

44

12

4113

A1

14

A2

(+) ( )

A2

A1

212422

414442

111412

(+)

1

12

5

14

9

11

2

22

6

24

10

21

3

32

7

34

11

31

4

42

8

44

12

4113

A1

14

A2

( )

A2

A1

212422

313432

414442

111412

(+)

1

12

5

14

9

11

2

22

6

24

10

21

3

32

7

34

11

31

4

42

8

44

12

4113

A1

14

A2

( )

A2

A1

212422

313432

414442

111412

Schemes Zelio Relay - plug-in relays RPM power relays

1

2

3

4

5

6

7

8

9

10

Page 50: Schneider Electric - Relay's Catalog Sept 09

4

Zelio Relay - plug-in relays

RelaysContact typesSymbol Configuration EU USA

Make contact (Normally Open)

NO SPST-NODPST-NOnPST-NO (1)

Break contact (Normally Closed)

NC SPST-NCDPST-NCnPST-NC (1)

Changeover Contact CO SPDTDPDTnPDT (1)

Utilisation categoriesCategory Type of current Applications

AC-1 a single-phasea 3-phase

Resistive or slightly inductive loads.

AC-3 a 3-phase Starting and braking of squirrel cage motors; reversing direction of rotation only after stopping of motor.

AC-4 a 3-phase Starting of squirrel cage motors, inching. Plugging, reversing direction of rotation.

DC-1 c Resistive or slightly inductive loads (2).

AC-14 a single-phase Control of electromagnetic loads (< 72 VA), auxiliary control relays, power contactors, electromagnetic solenoid valves and electromagnets.

AC-15 a single-phase Control of electromagnetic loads (> 72 VA), auxiliary control relays, power contactors, electromagnetic solenoid valves and electromagnets.

DC-13 c Control of electromagnetic loads, auxiliary control relays, power contactors, magnetic solenoid valves and electromagnets.

Protection categoriesCategory Explanation Condition

RT 0 Unenclosed relay Relay not provided with a protective case.

RT I Dust protected relay

Relay provided with a case which protects its mechanism from dust.

RT II Flux-proof relay Relay capable of being automatically soldered without allowing the migration of solder fluxes beyond the intended areas.

RT III Wash-tight relay Relay capable of being automatically soldered and then washed to remove flux residues without risk of ingress of flux or washing solvents.

RT IV Sealed relay Relay provided with a case which has no venting to the outside atmosphere.

RT V Hermetically sealed relay

Sealed relay having an enhanced level of sealing.

(1) n = number of contacts.(2) The switchable voltage can be doubled, for an equal current, by connecting two contacts in

series.

Technical presentation

1

2

3

4

5

6

7

8

9

10

Page 51: Schneider Electric - Relay's Catalog Sept 09

49

Zelio Relay - plug-in relays

Protection modulesWhenever an inductive load is de-energised (coil of a relay or of a contactor), an overvoltage appears at its terminals. This voltage peak can reach several thousand volts and a frequency of several MHz.It is likely to disturb the operation of automation systems which contain electronic devices.Protection modules are used to reduce the voltage peak on de-energisation and they therefore limit the energy of interference signals to a level that will not disturb surrounding coils and electronic devices.

These modules are used to avoid: electromagnetic compatibility problems, the deterioration of contact materials,the destruction of insulation due to overvoltage,the destruction of electronic components.

vvvv

Diode protection module (with or without LED)

Coil voltage with diode protection module (c only)

Advantagesaccumulation of energy allowing current flow in the same direction,absence of any voltage peaks at the coil terminals,low cost.

Disadvantages

bvvv

bincrease in relay drop-out time (3 to 4 times the usual time),no polarity protection,de-energisation of the relay.

vvv

Protection module with varistor

Coil voltage with varistor protection module (a and c)

Advantagescan be used with a and c supply,voltage peak limited to about 2 Un,little effect on relay drop-out time.

Disadvantages

bvvv

bno modification of coil’s own oscillating frequency,limitation of switching frequency.

vv

Protection module with RC circuit

Coil voltage with RC circuit protection module (a only)

S1 = S2 = Energy released

Advantagescoil oscillating frequency reduced to about 150 Hz,voltage peak limited to 3 Un,little effect on relay drop-out time.

Disadvantages

bvvv

bno protection for low voltages.v

U

t

Supply voltage

Energy released

BreakU

t

Supply voltage

Energy released

Break

U

t

Energyreleased

Break

Lim

itatio

n of

vol

tage

pe

aks

U

t

Energyreleased

Break

Lim

itatio

n of

vol

tage

pe

aks

S1

U1

U2

U

t

Break

S2 (with RC)

S1

U1

U2

U

t

Break

S2 (with RC)

Presentation

1

2

3

4

5

6

7

8

9

10

Page 52: Schneider Electric - Relay's Catalog Sept 09

50

Solid state interface modules

Output Input and output Very low level switching

Input Output

17.5 12 17.5 9.5 9.5/17.5

1 N/O 2 N/O 1 C/O 1 N/C + 1 N/O

1 N/O 1 C/O –

12 A 5 A – 5 A

c 24 V z 24 V, 4 V a 115…127 V a 110 V

c 24 V c 5, 24, 4 V a 115…127/50 Hz a 120…127/60 Hz a 230…240/50 Hz a 230…240/60 Hz

c 24 V

Mechanical for contacts and/or LED for control

LED for control

ABR 1S ABR 2S ABR 2pB312B ABS 2E ABS 2S

56 62 62 6

Applications Electromechanical interface modules

Functions Input

Width (mm) 17.5 9.5

Contact arrangement 1 N/O 2 N/O 1 C/O

1 N/O

Thermal current –

Control voltages c 110…127 V z 24 V, 4 V a 115…127 V a 230/240 V

c 24 V, 4 V a 115…127/50 Hz a 115…127/60 Hz a 230…240/50-60 Hz

Indication Mechanical for contacts and/or LED for control

LED for control

References ABR 1E ABR 2E

Pages 56 62

Selection guide Interfaces Interfaces for discrete signals

1

2

3

4

5

6

7

8

9

10

Page 53: Schneider Electric - Relay's Catalog Sept 09

51

Solid state interface modules

Output Input and output Very low level switching

Input Output

17.5 12 17.5 9.5 9.5/17.5

1 N/O 2 N/O 1 C/O 1 N/C + 1 N/O

1 N/O 1 C/O –

12 A 5 A – 5 A

c 24 V z 24 V, 4 V a 115…127 V a 110 V

c 24 V c 5, 24, 4 V a 115…127/50 Hz a 120…127/60 Hz a 230…240/50 Hz a 230…240/60 Hz

c 24 V

Mechanical for contacts and/or LED for control

LED for control

ABR 1S ABR 2S ABR 2pB312B ABS 2E ABS 2S

56 62 62 6

Applications Electromechanical interface modules

Functions Input

Width (mm) 17.5 9.5

Contact arrangement 1 N/O 2 N/O 1 C/O

1 N/O

Thermal current –

Control voltages c 110…127 V z 24 V, 4 V a 115…127 V a 230/240 V

c 24 V, 4 V a 115…127/50 Hz a 115…127/60 Hz a 230…240/50-60 Hz

Indication Mechanical for contacts and/or LED for control

LED for control

References ABR 1E ABR 2E

Pages 56 62

1

2

3

4

5

6

7

8

9

10

Page 54: Schneider Electric - Relay's Catalog Sept 09

52

Interfaces For discrete signalsElectromechanical interface modules

ABR-1 electromechanical interface modules are supplied in the form of compact modules, 17.5 mm wide.They are designed for interfacing discrete digital control signals exchanged within an automated system between the processing unit (PLC, numerical controller, etc) and the other components (contactors, solenoid valves, indicator lamps, proximity sensors, etc).These products are based on contactor technology and are notable for their excellent adaptation to industrial environments, ensured by the fact that they conform to the most recent IEC 947-5-1 standards.

CompositionThe ABR-1 range comprises 2 families :

Input interfaces Input interfaces are designed for switching input signals to the processor and are characterized by their high degree of contact reliability : less than 1 fault per 100 million operating cycles at c 17 V, 5 mA.The switching level is sufficiently high to ensure that the interfaces can directly control most contactors and indicator lamps.

Output interfaces Output interfaces are designed for the control of preactuators (contactors, solenoid valves, etc) for signalling devices (indicators lamps, audible warnings, etc). They are characterized by a high switching capacity and an average durability 5 times greater than that of traditional interface modules which incorporate standard relays.

1 Override contacts by pressing button (not holding it down) for a simple and quick test during setting up or maintenance operations on the installation

2 Green indicator showing the mechanical position of the contacts3 LED indicating the control signal state4 Channel identification : 5 individual characters for AB1-R/G or one AB1-SA2

marker tag5 Connection by screw clamp terminal enabling easy attachment of 2 wires per

terminal. The layout of the connection terminals for both families (input and output) is designed for rational wiring and a clear separation between the incoming (processing) and outgoing (power and process control) circuits.

162

64

5

214

3

162

64

5

214

3

162

65

5

3

412

162

65

5

3

412

Presentation

Presentation:page 52

Characteristics:page 53

Curves:page 55

Dimensions, schemes:page 57

1

2

3

4

5

6

7

8

9

10

Page 55: Schneider Electric - Relay's Catalog Sept 09

53

Interfaces For discrete signalsElectromechanical interface modules

Examples of applications with PLCs

(1) Essential on inductive loads (can be replaced with peak limiter ).

–/

+/

+

A2

A1

A2

A1

A2

A1

A2

A1

PushbuttonsSeries contacts

2-wiresensors

3-wiresensors

PushbuttonsSeries contacts

2-wiresensors

PLCPositive logic discrete inputs

–/

+/

+

A2

A1

A2

A1

A2

A1

A2

A1

PushbuttonsSeries contacts

2-wiresensors

3-wiresensors

PushbuttonsSeries contacts

2-wiresensors

PLCPositive logic discrete inputs

–/

+/

+

24...125 V ...240 V

A1

A2

(1) (1)

A1

A2

A1

A2

PLCPositive logic transistor (or relay) outputs

–/

+/

+

24...125 V ...240 V

A1

A2

(1) (1)

A1

A2

A1

A2

PLCPositive logic transistor (or relay) outputs

Environment

Conforming to standards IEC 947-5-1Product certifications UL, CSA, BV, LROS, DNVDegree of protection Conforming to IEC 529

(protection against direct contact)IP 00

Protective treatment “TC”Flame resistance Conforming to IEC 695-2-1 Incandescent wire °C 50

Conforming to UL 94 V0Shock resistance Conforming to IEC 6-2-27 Semi-sinusoidal waves 11 ms 50 gnVibration resistance Conforming to IEC 6-2-6 10…55 Hz 6 gnResistance to electrostatic charges

Conforming to IEC 01-2 Level 3 kV

Resistance to rapid transients

Conforming to IEC 01-4 On power supply kV 2On I/O kV 1

Resistance to shock waves

Conforming to IEC 255-4 Waveform 1.2/50 ms ; 0.5 J

U ≤ 50 V kV 0.5U > 50 V kV 2.5

Cross-sections which may be connected

Flexible cable with no cable end 1 or 2-wire mm2 0.6…2.5Flexible cable with cable end 1 or 2-wire mm2 0.34…2.5Rigid cable 1-wire mm2 0.27…4

2-wire mm2 0.27…2.5Operating position AnyAmbient air temperature around the device

Unrestricted operation °C - 5…+ 40Permissible at Un °C - 20…+ 60Storage °C - 40…+ 70

Operating altitude m ≤ 3000Installation category Conforming to IEC 947-1 IIDegree of pollution Conforming to IEC 947-5-1 3Mounting Standard rails 5 1 4

Environment

Conforming to standards IEC 947-5-1Product certifications UL, CSA, BV, LROS, DNVDegree of protection Conforming to IEC 529

(protection against direct contact)IP 00

Protective treatment “TC”Flame resistance Conforming to IEC 695-2-1 Incandescent wire °C 50

Conforming to UL 94 V0Shock resistance Conforming to IEC 6-2-27 Semi-sinusoidal waves 11 ms 50 gnVibration resistance Conforming to IEC 6-2-6 10…55 Hz 6 gnResistance to electrostatic charges

Conforming to IEC 01-2 Level 3 kV

Resistance to rapid transients

Conforming to IEC 01-4 On power supply kV 2On I/O kV 1

Resistance to shock waves

Conforming to IEC 255-4 Waveform 1.2/50 ms ; 0.5 J

U ≤ 50 V kV 0.5U > 50 V kV 2.5

Cross-sections which may be connected

Flexible cable with no cable end 1 or 2-wire mm2 0.6…2.5Flexible cable with cable end 1 or 2-wire mm2 0.34…2.5Rigid cable 1-wire mm2 0.27…4

2-wire mm2 0.27…2.5Operating position AnyAmbient air temperature around the device

Unrestricted operation °C - 5…+ 40Permissible at Un °C - 20…+ 60Storage °C - 40…+ 70

Operating altitude m ≤ 3000Installation category Conforming to IEC 947-1 IIDegree of pollution Conforming to IEC 947-5-1 3Mounting Standard rails 5 1 4

Characteristics

1

2

3

4

5

6

7

8

9

10

Page 56: Schneider Electric - Relay's Catalog Sept 09

54

Interfaces For discrete signalsElectromechanical interface modules

Control circuit characteristics (40°C ambient temperature)Type of interface ABR

1Sp02BABR 1ppp8B

ABR 1ppp8E

ABR 1Ep12F

ABR 1ppp1F

ABR 1Ep11M

ABR 1Ep01M

Rated voltage (Uc) V c 24 z 24 z 4 c 110...127

a 115...127

a 230...240

a 230...240

Current frequency Hz – 50/60 50/60 – 50/60 50/60 50/60Energization threshold (at ± 5 %) V 15 16.5 34 75 6 170 164Maximum operating voltage c / a V 30 30 53 140 140 264 264Maximum drop-out (at ± 5 %) voltage (Uo) c / a V 3.2 3. .5 16 34 6 7Maximum current (Un) c / a mA 62 62/55 36/32 15 7 5.5Minimum holding current c / a mA 6.6 4.9/5.2 4.7/5.4 1.5 2.4 2 1.5Maximum dissipated power 50 Hz/60 Hz W 1.5 1.5 1.5 1.5 1.5 1.5 1.5Disappearance of voltage maximum time up to which contact is maintained

ms 3 10 10 6 5 6

Display of control circuit by LED No Yes Yes Yes Yes Yes NoBuilt-in protection reversed polarity Yes Yes Yes Yes – – –

Contact characteristicsType of interface ABR 1Epppp ABR 1Spppp

Maximum switching voltage a V 252 252 c V 125 125

Maximum rated operating voltage Ue

Conforming to IEC 947-5-1 a V 230 230 c V 125 125

Operating current frequency Hz 50/60 50/60Thermal current Ith Conforming to IEC 947-1 A 2 12Rated operating current (Ie) per 1 million operating cycles

Conforming to IEC 947-5-1 Ue : a 230 V

AC12 A 2 4AC13 A 1 1AC14 A 1 1AC15 A 1 1

Conforming to IEC 947-5-1 Ue : c 24 V

DC12 A 2 5DC13 A 1 1

Minimum switching capacity mA 3 3Minimum switching voltage V 17 17Protection against short-circuits

For Ik ≤ 2.5 kA (a) and ≤ 100 A (c) Type and value of recommended fuse

A gG/gF : 16 gG/gF : 16

Low power switching reliability of contacts (17 V - 5 mA)

Number of faults per “n” million operating cycles

10- 10-

Other characteristicsOperating time at Un and at 20 °C

Between energization of coil and closing of N/O contact

ms ≤ 12

Between energization of coil and opening of N/C contact

ms ≤ 12

Between de-energization of coil and opening of N/O contact

ms ≤ 12

Between de-energization of coil and closing of N/C contact

ms ≤ 12

Duration of bounce ms ≤ 3Contact bridging times between contact “N/C” and “N/O”

Maximum make before break or break before make time

ms 1

Maximum operating rate

At no-load Hz 6At Ie Hz 0.5

Mechanical durability in millions of operating cycles

ABR-1 (1 N/O or 2 N/O) ≥ 20 millionABR-1 (1 C/O or 1 N/C + 1 N/O) ≥ 10 million

Rated isolation voltage Conforming to IEC 947-1 V 250Conforming to VDE 0110 group C V 250

Insulation test voltage for 1 min.

Between coil circuit and contact circuits kV 4Between wired interface and earth kV 2.5Between independent contacts kV 1.5

Characteristics (continued)

Presentation:page 52

Characteristics:page 53

Curves:page 55

Dimensions, schemes:page 57

1

2

3

4

5

6

7

8

9

10

Page 57: Schneider Electric - Relay's Catalog Sept 09

55

Interfaces For discrete signalsElectromechanical interface modules

Electrical durability of contactsTest conditions : in accordance with standard IEC 947-5-1 set up for rated control voltage, operating rate : 100 cycles/hour. (0.5 Hz).

a.c. loads

AC-12 : control of resistive loads and isolated solid state loads via optocoupler cos j ≥ 0.9

AC-13 : control of isolated solid state loads via transformer cos j ≥ 0.65

AC-14 : control of weak electromagnetic loads of electromagnets ≤ 72 VAmake: cos j = 0.3break: cos j = 0.3AC-15 : control of electromagnetic loads of electromagnets > 72 VAmake: cos j = 0.7break: cos j = 0.4

1 24 V2 4 V3 127 V4 230 V

d.c. loads

1 24 V2 4 V3 127 V

DC-12 : control of resistive loads and isolated solid state loads via optocoupler L/R ≤ 1 ms

DC-13 : control of electromagnets L/R ≤ 2 x (Ue x Ie) in ms.Ue: rated operating voltageIe: rated operating current

5

4

3

2

1

1 2 3 4 5(A)

6

0

0

34

2

6

Operating cycles in millions

5

4

3

2

1

1 2 3 4 5(A)

6

0

0

34

2

6

Operating cycles in millions

5

4

3

2

1

1 2 3 4 5(A)

6

0

0

6

3

1

4

2

Operating cycles in millions

5

4

3

2

1

1 2 3 4 5(A)

6

0

0

6

3

1

4

2

Operating cycles in millions

2

1

0,5 1 1,5 2 2,5

(A)

3

0

0

3

1

2

3

4

Operating cycles in millions

2

1

0,5 1 1,5 2 2,5

(A)

3

0

0

3

1

2

3

4

Operating cycles in millions

5

4

3

2

1

0

1 2 3 4 5

(A)

2

3

6

60

1

Operating cycles in millions

5

4

3

2

1

0

1 2 3 4 5

(A)

2

3

6

60

1

Operating cycles in millions

2

1

0,5 1 1,5 2 2,5

(A)

3

0

0

3

3

1

2

Operating cycles in millions

2

1

0,5 1 1,5 2 2,5

(A)

3

0

0

3

3

1

2

Operating cycles in millions

Curves

1

2

3

4

5

6

7

8

9

10

Page 58: Schneider Electric - Relay's Catalog Sept 09

56

Interfaces For discrete signalsElectromechanical interface modulesControl circuit : a.c. or d.c.

Input interface modules (1) (17.5 mm pitch)Display Composition Control circuit Enclosure

colourReference Weight

V kgMechanical (2) 1 N/O a 230/240 Grey ABR 1E101M 0.090

1 C/O a 230/240 Grey ABR 1E301M 0.090Mechanical (2) + LED (3)

1 N/O z 24 Grey ABR 1E118B 0.095z 4 Grey ABR 1E118E 0.095c 110...127 (4) Grey ABR 1E112F 0.095a 115...127 Grey ABR 1E111F 0.095a 230/240 Grey ABR 1E111M 0.095

2 N/O z 24 Grey ABR 1E418B 0.095z 4 Grey ABR 1E418E 0.095c 110...127(4) Grey ABR 1E412F 0.095a 115...127 Grey ABR 1E411F 0.095a 230/240 Grey ABR 1E411M 0.095

1 C/O z 24 Grey ABR 1E318B 0.095z 4 Grey ABR 1E318E 0.095c 110...127(4) Grey ABR 1E312F 0.095a 115...127 Grey ABR 1E311F 0.095a 230/240 Grey ABR 1E311M 0.095

Output terminals-relays (1) (17.5 mm pitch)Display Composition Control circuit Enclosure

colourReference Weight

V kgMechanical (2) 1 N/O c 24 Grey ABR 1S102B 0.090

2 N/O c 24 Grey ABR 1S402B 0.0901 C/O c 24 Grey ABR 1S302B 0.0901 N/C + 1 N/O c 24 Grey ABR 1S602B 0.090

Mechanical (2) + LED (3)

1 N/O z 24 Grey ABR 1S118B 0.095z 4 Grey ABR 1S118E 0.095a 115...127 Grey ABR 1S111F 0.095

2 N/O z 24 Grey ABR 1S418B 0.095z 4 Grey ABR 1S418E 0.095a 110 Grey ABR 1S411F 0.095

1 C/O z 24 Grey ABR 1S318B 0.095z 4 Grey ABR 1S318E 0.095a 110 Grey ABR 1S311F 0.095

1 N/C + 1 N/O z 24 Grey ABR 1S618B 0.095z 4 Grey ABR 1S618E 0.095a 110 Grey ABR 1S611F 0.095

Commoning linksDescription For common Colour Distance

between cable ends

Reference Weight

cm kgCommoning links in modules 8 x 1 mm2

Coil White 12 ABF C08R12W 0.0202 ABF C08R02W 0.010

a Red 12 ABF C08R12R 0.0202 ABF C08R02R 0.010

c Blue 12 ABF C08R12B 0.0202 ABF C08R02B 0.010

(1) Connection by screw-clamp.(2) By green mechanical indicator light for contact(s) activated electrically or mechanically by

pressing the test button. (3) By green LED illuminated when control signal is present.(4) With polarization (+ on A1, - on A2).

162

64

ABR 1E101M

162

64

ABR 1E101M

12

15

ABR 1E318B

12

15

ABR 1E318B

162

65

ABR 1S102B

162

65

ABR 1S102B

162

73

ABF C08Rppp

162

73

ABF C08Rppp

Presentation:page 52

Characteristics:page 53

Curves:page 55

Dimensions, schemes:page 57

Presentation:page 52

Characteristics:page 53

Curves:page 55

Dimensions, schemes:page 57

References

1

2

3

4

5

6

7

8

9

10

Page 59: Schneider Electric - Relay's Catalog Sept 09

57

Interfaces For discrete signalsElectromechanical interface modules

DimensionsABR 1E ABR 1S

Schemesc 24 V or a 230 V interfaces with mechanical indication1 N/O 1 C/O 2 N/O 1 N/C + 1 N/O

z 24 V or z 48 V interfaces with mechanical indication + LED1 N/O 1 C/O 2 N/O 1 N/C + 1 N/O

c / a 110 V or a 230 V interfaces with mechanical indication + LED1 N/O 1 C/O 2 N/O 1 N/C + 1 N/O

78

75

70,517,5

74

63

78

75

70,517,5

74

63

78

75

70,517,5

74

63

78

75

70,517,5

74

63

A2

1314

A1

A2

1314

A1

1114

12

A2 A1

1114

12

A2 A1

1314

2324

A2

A1

1314

2324

A2

A1

2324

1112

A2

A1

2324

1112

A2

A1

A1

1314

A2

A1

1314

A2

1114

12

A2

A1

1114

12

A2

A1

1314

2324

A2 A1

1314

2324

A2 A1

2324

1112

A1

A2

2324

1112

A1

A2

1314

A1

(+)

A2

1314

A1

(+)

A2

1114

12

A1

(+)

A2

1114

12

A1

(+)

A2

1314

2324

A1

(+)

A2

1314

2324

A1

(+)

A2

2324

1112

A1

(+)

A2

2324

1112

A1

(+)

A2

Dimensions, schemes

1

2

3

4

5

6

7

8

9

10

Page 60: Schneider Electric - Relay's Catalog Sept 09

5

Interfaces For discrete signalsSlim electromechanical interface modules

ABR-2 electromechanical interface modules complement the ABR-1 range.They are characterised by micro relay technology which allows reduced dimensions and very low switching levels (TTL, HCMOS, analogue signals).The ABR-2 family is in the form of slim compact modules, 9.5 mm wide for input interface modules, 12 mm wide for output interface modules and 17.5 mm wide for very low level switching products.

DescriptionThe ABR-2 comprises 3 families :

Input interfaces (9.5 mm pitch) Input interfaces are designed for switching input signals to a processor and are characterized by their high degree of contact reliability : less than 1 fault per 100 million operating cycles at c 17 V, 5 mA.An assured immunity to current leakages ≤ 2 mA, and a wide coil voltage range (0.7 to 1.25 Un).

Output interfaces (12 mm pitch) Output interfaces are designed for the control of preactuators (contactors, solenoid valves, etc) for signalling devices (indicators lamps, audible warnings etc). They are characterized by a high switching capacity and an assured immunity to current leakages £ 2 mA. A lower cost version without LED signalling is available.2 mA. A lower cost version without LED signalling is available.

Low level switching input and output interfaces (17.5 mm pitch) with 1 C/O contact. These interfaces are designed for switching logic (TTL or HCMOS) and analogue signals.Warning : never switch inductive loads with this type of interface.

The front panel of the ABR-2 electromechanical interface module comprises :1 LED indicating the control signal state2 Channel identification : 5 individual characters for AB1-R/G or 1 AB1-SA2

marker tag3 Connection by screw clamp terminal enabling easy attachment of 2 wires per

terminal. The layout of the connection terminals for both families (input and output) is designed for rational wiring and a clear separation between the incoming (processing) and outgoing (power and process control) circuits.

3

2

1

3

2

1

3

2

1

3

2

1

ABR-2SB312B

ABR2SB312B-PRO-3-B

3

2

1

ABR-2SB312B

ABR2SB312B-PRO-3-B

3

2

1

Presentation:page 5

Characteristics:page 59

Curves:page 61

References:page 62

Dimensions, schemes:page 63

Presentation:page 5

Characteristics:page 59

Curves:page 61

References:page 62

Dimensions, schemes:page 63

Presentation

1

2

3

4

5

6

7

8

9

10

Page 61: Schneider Electric - Relay's Catalog Sept 09

59

Interfaces For discrete signalsSlim electromechanical interface modules

Examples of applications with PLCs

(1) Essential on inductive loads (can be replaced with peak limiter ).

–/

+/

+/

13 14 13 14 13 14

A1

A2

A1

A2

A1

A2

PLCPositive logic discrete inputs

PushbuttonsSeries contacts

2-wiresensors

3-wiresensors

ABR 2Epppp

Processpowersupply

Processingpowersupply

–/

+/

+/

13 14 13 14 13 14

A1

A2

A1

A2

A1

A2

PLCPositive logic discrete inputs

PushbuttonsSeries contacts

2-wiresensors

3-wiresensors

ABR 2Epppp

Processpowersupply

Processingpowersupply

+

+A

1

A2

(1) (1)

C1

A1

A2

A1

A2

13 14 13 14 13 14

A1

A2

12 14

C2

OV

11

PLCPositive logic transistor (or relay) outputs

PLCAnalogue inputs

Channel X

Analogue sensors

ABR 2Spppp ABR 2SB12B

+

+A

1

A2

(1) (1)

C1

A1

A2

A1

A2

13 14 13 14 13 14

A1

A2

12 14

C2

OV

11

PLCPositive logic transistor (or relay) outputs

PLCAnalogue inputs

Channel X

Analogue sensors

ABR 2Spppp ABR 2SB12B

Environment

Conforming to standards IEC 947-5-1Product certifications UL, CSA, BV, LROS, DNVDegree of protection Conforming to IEC 529

(protection against direct contact)IP 20

Protective treatment “TC”Flame resistance Conforming to IEC 695-2-1 Incandescent wire °C 960

Conforming to UL 94 V0Shock resistance Conforming to IEC 6-2-27 Semi-sinusoidal waves 11 ms 30 gnVibration resistance Conforming to IEC 6-2-6 10…150 Hz 3 gnResistance to electrostatic discharges

Conforming to IEC 01-2 Level 3 kV

Resistance to electromagnetic fields

Conforming to IEC 01-3 Level 3 ; 27…1000 MHz V/m 10

Resistance to rapid transients

Conforming to IEC 01-4 Level 3

On power supply kV 2On I/O kV 1

Resistance to shock waves

Conforming to IEC 947-1 Waveform 1.2/50 ms ; 0.5 J

U < 50 V kV 0.5U < 150 V kV 1.5U < 300 V kV 2.5

Cross-sections which may be connected

Flexible cable with no cable end 1 or 2-wire mm2 0.6…2.5Flexible cable with cable end 1 or 2-wire mm2 0.34…2.5Rigid cable 1-wire mm2 0.27…4

Operating position AnyAmbient air temperature Unrestricted operation °C - 5…+ 40

Operation from 0.5...1.1 Us (assigned voltage)

°C - 5…+ 55

Operation restricted to Us (assigned voltage)

°C - 25…+ 70 (2)

Storage °C - 40…+ 0Operating altitude m ≤ 3000Installation category Conforming to IEC 947-1 IIDegree of pollution Conforming to IEC 947-1 2Mounting Standard rails 5 1 4(2) Leave space of 8 mm between ABR-2S1ppp for an ambient temperature ≥ 55 °C

Environment

Conforming to standards IEC 947-5-1Product certifications UL, CSA, BV, LROS, DNVDegree of protection Conforming to IEC 529

(protection against direct contact)IP 20

Protective treatment “TC”Flame resistance Conforming to IEC 695-2-1 Incandescent wire °C 960

Conforming to UL 94 V0Shock resistance Conforming to IEC 6-2-27 Semi-sinusoidal waves 11 ms 30 gnVibration resistance Conforming to IEC 6-2-6 10…150 Hz 3 gnResistance to electrostatic discharges

Conforming to IEC 01-2 Level 3 kV

Resistance to electromagnetic fields

Conforming to IEC 01-3 Level 3 ; 27…1000 MHz V/m 10

Resistance to rapid transients

Conforming to IEC 01-4 Level 3

On power supply kV 2On I/O kV 1

Resistance to shock waves

Conforming to IEC 947-1 Waveform 1.2/50 ms ; 0.5 J

U < 50 V kV 0.5U < 150 V kV 1.5U < 300 V kV 2.5

Cross-sections which may be connected

Flexible cable with no cable end 1 or 2-wire mm2 0.6…2.5Flexible cable with cable end 1 or 2-wire mm2 0.34…2.5Rigid cable 1-wire mm2 0.27…4

Operating position AnyAmbient air temperature Unrestricted operation °C - 5…+ 40

Operation from 0.5...1.1 Us (assigned voltage)

°C - 5…+ 55

Operation restricted to Us (assigned voltage)

°C - 25…+ 70 (2)

Storage °C - 40…+ 0Operating altitude m ≤ 3000Installation category Conforming to IEC 947-1 IIDegree of pollution Conforming to IEC 947-1 2Mounting Standard rails 5 1 4(2) Leave space of 8 mm between ABR-2S1ppp for an ambient temperature ≥ 55 °C

Characteristics

1

2

3

4

5

6

7

8

9

10

Page 62: Schneider Electric - Relay's Catalog Sept 09

60

Interfaces For discrete signalsSlim electromechanical interface modules

Control circuit characteristics (40°C ambient temperature)Type of interface ABR

2E112BABR 2E112E

ABR 2E115F

ABR 2E116F

ABR 2E111M

ABR 2S112B

ABR 2S102B

ABR 2pB312B (1)

Rated voltage (Us) V c 24 c 4 z 115…127

z 120...127

a 230...240

c 24 c 24 c 24

Current frequency Hz – – 50 60 50/60 – – –Energization threshold V 16.9 37.3 93 97 16 16.9 14.5 16.9Maximum operating voltage V 2. 57.6 140 140 264 2. 2. 2.Maximum drop-out voltage (Uo) V 3. .5 25.4 25.4 4 3. 2 3.Maximum current (at Us) mA 19.5 11 14 16 15 2 1 23Minimum holding current mA 2 2 2.5 2.5 2.5 2 1.3 2Maximum dissipated power (at Us) 50 Hz W – – 0.66 – 0.54 – – –

60 Hz W 0.45 0.52 – 0.73 0.77 0.64 0.43 0.55Disappearance of voltage maximum time up to which contact is maintained

ms 1 1 10 10 10 1 5 1

Display of control circuit by LED Yes Yes Yes Yes Yes Yes No YesBuilt-in protection reversed polarity Yes Yes – – – Yes Yes Yes

Contact characteristics (40°C ambient temperature)Type of interface ABR 2Epppp ABR 2S112B ABR 2S102B ABR 2pB312B (1)

Composition 1 N/O 1 N/O 1 N/O 1 C/OMaximum rated operating voltage (Ue max)

Conforming to IEC 947-5-1 a V 127 230 230 4c V 100 120 120 4

Maximum switching voltage a V 140 250 250 60c V 125 150 150 60

Operating current frequency Hz 50/60 50/60 50/60 50/60Thermal current Ith Conforming to IEC 947-1 A 1 5 5 0.05Rated operating current (Ie) for 1 million operating cycles

Conforming to IEC 947-5-1 Ue max

AC12 A 1 3 3 –AC14 A 0.5 1 1 –AC15 A 0.5 1 1 –

Conforming to IEC 947-5-1 Ue : c 24 V

DC12 A 1 1.7 1.7 –DC13 A 1 1.5 1.5 –

Minimum switching current mA 1 5 5 0.01Minimum switching voltage V 5 5 5 0.01Protection against short-circuits

For Ik ≤ 1 kA (a) and ≤ 100 A (c) Type and value of recommended fuse

Type : quick-blow fuse with high breaking capacityA 2 6.3 6.3 0.4

Low level contact reliability (17 V, 5 mA)/ABR-2pB (30 mV, 10 µA)

Number of faults per “n” million operating cycles

1 per 100 million

Other characteristicsMaximum operating time at Us (bounce included)

Between energization of coil and closing of N/O contact

c ms 10 10 10 6a ms 30 – – –

Between energization of coil and opening of N/C contact

ms – – – 6

Between de-energization of coil and opening of N/O contact

c ms 6 12 5 6a ms 30 – – –

Between de-energization of coil and closing of N/C contact

ms – – – 6

Maximum duration of bounce ms 5 5 5 2No make before break guaranteed between “N/C” and “N/O” contacts

Maximum make before break or break before make time

On energization ms – – – 5On de-energization ms – – – 2

Maximum operating rate

At no-load Hz 10 10 10 10At Ie Hz 0.5 0.5 0.5 –

Mechanical durability in millions of operating cycles

20 10 10 20

Rated insulation voltage

Conforming to IEC 947-1 V 300 300 300 300Conforming to VDE 0110 group C V 250 250 250 250

Insulation test voltage for 1 min

Coil circuit/contact circuits kV rms 2 4 4 1.5Wired interface/earth kV rms 2.5 2.5 2.5 2.5Between open contacts kV rms 0.75 1 1 1

(1) Do not switch inductive loads.(1) Do not switch inductive loads.

Presentation:page 5

Characteristics:page 59

Curves:page 61

References:page 62

Dimensions, schemes:page 63

Presentation:page 5

Characteristics:page 59

Curves:page 61

References:page 62

Dimensions, schemes:page 63

Characteristics (continued)

1

2

3

4

5

6

7

8

9

10

Page 63: Schneider Electric - Relay's Catalog Sept 09

61

Interfaces For discrete signalsSlim electromechanical interface modules

Electrical durability of contacts (ABR 2S)Test conditions : in accordance with standard IEC 947-5-1 set up for rated control voltage.

a.c. loads

1 24 V2 4 V3 115 V4 230 V

AC12 : control of resistive loads and isolated solid state loads via optocouplercos j ≥ 0.9

AC14 : control of weak electro-magnetic loads of electro-magnets y 72 VAmake : cos j = 0.3break : cos j = 0.3AC15 : control of electro-magnetic loads of electro-magnets > 72 VAmake : cos j = 0.7break : cos j = 0.4

d.c. loads

1 24 V2 4 V3 115 V

DC12 : control of resistive loads and isolated solid state loads via optocoupler L/R ≤ 1 ms

DC13 : control of electro-magnets L/R ≤ 2 x (Ue x Ie) in ms.Ue : rated operating voltageIe : rated operating current(with a load protection diode)

5

4

3

2

1

1 2 3 4 5(A)

6

0

0

3

4

2

6

1

Operating cycles in millions

5

4

3

2

1

1 2 3 4 5(A)

6

0

0

3

4

2

6

1

Operating cycles in millions

2

1

0,5 1 1,5 2 2,5(A)

3

0

0

3

2

43

1

Operating cycles in millions

2

1

0,5 1 1,5 2 2,5(A)

3

0

0

3

2

43

1

Operating cycles in millions

2

1

0,5 1 1,5 2 2,5

(A)

3

0

0

3

1

23

Operating cycles in millions

2

1

0,5 1 1,5 2 2,5

(A)

3

0

0

3

1

23

Operating cycles in millions

2

1

0

0,5 1 1,5 2 2,5

(A)

23

3

30

1

Operating cycles in millions

2

1

0

0,5 1 1,5 2 2,5

(A)

23

3

30

1

Operating cycles in millions

Curves

1

2

3

4

5

6

7

8

9

10

Page 64: Schneider Electric - Relay's Catalog Sept 09

62

Interfaces For discrete signalsSlim electromechanical interface modulesControl circuit : a.c. or d.c.

Input modules (9.5 mm pitch)Indication Composition Control circuit Sold in

lots ofUnit reference

Weight

V kgWith LED 1 N/C c 24 5 ABR 2E112B 0.032

c 4 5 ABR 2E112E 0.032

a 115...127 (50 Hz) 5 ABR 2E115F 0.035

a 120...127 (60 Hz) 5 ABR 2E116F 0.035

a 230...240 (50/60 Hz) 5 ABR 2E111M 0.036

Output modules (12 mm pitch)Indication Composition Control circuit Sold in

lots ofUnit reference

Weight

V kgWithout 1 N/C c 24 5 ABR 2S102B 0.040

With LED 1 N/C c 24 5 ABR 2S112B 0.041

Modules for very low level switching (17.5 mm pitch)Indication Composition Control circuit Reference Weight

V kgInput

With LED 1 C/O (1) c 24 ABR 2EB312B 0.04

OutputWith LED 1 C/O (1) c 24 ABR 2EB312B 0.04

Flexible comb accessoriesDescription For common Colour Distance

between cable ends

Reference Weight

cm kgFlexible comb modularity 8 x 1 mm2

Coil White 12 ABF C08R12W 0.020

2 ABF C08R02W 0.010

a Red 12 ABF C08R12R 0.020

2 ABF C08R02R 0.010

c Blue 12 ABF C08R12B 0.020

2 ABF C08R02B 0.010

(1) Do not switch inductive loads.

163

62

ABR 2E112B

163

62

ABR 2E112B

163

63

ABR 2S112B

163

63

ABR 2S112B

163

64

ABR 2EB112B

163

64

ABR 2EB112B

163

65

ABF C08Rppp

163

65

ABF C08Rppp

Presentation:page 5

Characteristics:page 59

Curves:page 61

References:page 62

Dimensions, schemes:page 63

Presentation:page 5

Characteristics:page 59

Curves:page 61

References:page 62

Dimensions, schemes:page 63

References

1

2

3

4

5

6

7

8

9

10

Page 65: Schneider Electric - Relay's Catalog Sept 09

63

Interfaces For discrete signalsSlim electromechanical interface modules

DimensionsABR 2E11pp ABR 2S1p2B

ABR 2EB312B ABR 2SB312B

Circuit diagramsABR 2E112B (c 24 V) ABR 2E112E (c 4 V) ABR 2E11pF/M (a 115...240 V)

ABR 2S102B (c 24 V) ABR 2S112B (c 24 V) ABR 2pB312B (c 24 V)

78

75

70,59,5

7478

75

70,59,5

7478

75

70,512

74

78

75

70,512

74

78

75

70,5

63

17,5

74

78

75

70,5

63

17,5

74

78

75

70,5

63

17,5

74

78

75

70,5

63

17,5

74

+A

1

–A2

13 14

+A

1

–A2

13 14

+A

1

–A2

1413

+A

1

–A2

1413

A1

– A

213 14

A1

– A

213 14

1314

+A

1

–A2

1314

+A

1

–A2

1314

+A

1

–A2

1314

+A

1

–A2

141112

+A

1

–A2

141112

+A

1

–A2

Dimensions, schemes

1

2

3

4

5

6

7

8

9

10

Page 66: Schneider Electric - Relay's Catalog Sept 09

64

Interfaces For discrete signalsSlim solid-state interface modules

The ABS-2 solid-state interface relays are supplied in the form of compact modules which appear identical to the ABR-2 electromechanical family.They are designed for interfacing discrete digital control signals exchanged within an automated system between the processor (PLC, numerical controller, etc) and the other components (contactors, solenoid valves, indicator lamps, proximity sensors, etc).They are suitable for use in equipment which requires the benefits of electronic technology : a high operating rate, virtually unlimited durability, silent operation, etc.These products are notable for their high performance and excellent adaptation to industrial environments, ensured by the fact that they conform to the most recent IEC standards.

CompositionThe ABS-2 range comprises 2 families :

Input interfaces The 9.5 mm wide input interfaces are designed for switching input signals to processors. They offer a wide choice of electrical isolation between signals due to the wide range of input voltages from c 5 V to a 230 V.

Output interfaces Output interfaces are designed for the control of preactuators (contactors, solenoid valves, etc) for the signalling devices (indicator lamps, audible warnings, etc). Two widths are available, 9.5 and 17.5 mm, depending on the switched current.

The 17.5 mm version comprises a 9.5 mm interface and an integrated mm spacer. This device can, with its increased ventilation, switch high levels of currents.

The front panel of the ABS-2 slim solid-state interface modules comprises:1 LED indicating the state of the control signal.2 Channel identification : 5 individual characters for AB1-/G or one AB1-SA2 marker

tag.3 Connection by screw clamp terminal enabling easy attachment of 2 wires per

terminal. The layout of the connection terminals for both families (input and output) is designed for rational wiring and a clear separation between the incoming (processing) and outgoing (power and process control) circuits.

4 Integrated spacer.

3

2

1

163

0

3

2

1

163

0

ABS2INTERSORT-PRO-3-B

3

2

1

163

7

ABS2INTERSORT-PRO-3-B

3

2

1

163

7

ABS-2

ABS2-PRO-3-B

3

2

1

4

163

79

ABS-2

ABS2-PRO-3-B

3

2

1

4

163

79

Presentation:page 64

Characteristics:page 65

Curves:page 6

References:page 6

Dimensions, schemes:page 69

Presentation:page 64

Characteristics:page 65

Curves:page 6

References:page 6

Dimensions, schemes:page 69

Presentation

1

2

3

4

5

6

7

8

9

10

Page 67: Schneider Electric - Relay's Catalog Sept 09

65

Interfaces For discrete signalsSlim solid-state interface modules

Examples of applications with PLCsInterfacing PLC discrete inputs

Interfacing PLC discrete outputs

+

+

14

13

14

13

ABS - 2E

13

14

PNP 115/230 V

13

14

13

14A

1

A2

A1

A2

A1

A2

A1

A2

A1

A2

PLCPositive logic discrete inputs

PushbuttonsSeries contacts

2-wiresensors

3-wiresensors

PushbuttonsSeries contacts

2-wiresensors

Process power supply

Processing power supply

+

+

14

13

14

13

ABS - 2E

13

14

PNP 115/230 V

13

14

13

14A

1

A2

A1

A2

A1

A2

A1

A2

A1

A2

PLCPositive logic discrete inputs

PushbuttonsSeries contacts

2-wiresensors

3-wiresensors

PushbuttonsSeries contacts

2-wiresensors

Process power supply

Processing power supply

+

+

A1

A2

A1

A2

A1

A2

ABS - 2S

F

13 14 13 14 13 14

PLCPositive logic transistor (or relay) outputs

+

+

A1

A2

A1

A2

A1

A2

ABS - 2S

F

13 14 13 14 13 14

PLCPositive logic transistor (or relay) outputs

Environment

Conforming to standards IEC 947-5-1 Draft standard IEC 17 B secretariat 200

Product certifications UL, CSA, BV, LROS, DNVDegree of protection Conforming to IEC 529

(protection against direct contact)IP 20

Protective treatment “TC”Flame resistance Conforming to IEC 695-2-1 Incandescent wire °C 960

Conforming to UL 94 V0Shock resistance Conforming to IEC 6-2-27 Semi-sinusoidal waves 11 ms 30 gnVibration resistance Conforming to IEC 6-2-6 10…150 Hz 5 gnResistance to electrostatic discharges

Conforming to IEC 01-2 Level 3 kV

Resistance to electromagnetic fields

Conforming to IEC 01-3 Level 3 ; 27…1000 MHz V/m 10

Resistance to rapid transients

Conforming to IEC 01-4 Level 3

On power supply kV 2On I/O kV 1

Resistance to shock waves

Conforming to IEC 947-1 Waveform 1.2/50 ms ; 0.5 J

U < 50 V kV 0.5U < 150 V kV 1.5U < 300 V kV 2.5

Cross-sections which may be connected

Flexible cable with no cable end 1 or 2-wire mm2 0.6…2.5Flexible cable with cable end 1 or 2-wire mm2 0.34…2.5Rigid cable 1-wire mm2 0.27…4

Operating position AnyAmbient air temperature around the device

Unrestricted operation °C - 5…+ 55Operation at Us °C - 25…+ 70Storage °C - 40…+ 0

Operating altitude m ≤ 300Installation category Conforming to IEC 947-1 IIDegree of pollution Conforming to IEC 947-1 2Mounting Standard rails 5 1 4

Environment

Conforming to standards IEC 947-5-1 Draft standard IEC 17 B secretariat 200

Product certifications UL, CSA, BV, LROS, DNVDegree of protection Conforming to IEC 529

(protection against direct contact)IP 20

Protective treatment “TC”Flame resistance Conforming to IEC 695-2-1 Incandescent wire °C 960

Conforming to UL 94 V0Shock resistance Conforming to IEC 6-2-27 Semi-sinusoidal waves 11 ms 30 gnVibration resistance Conforming to IEC 6-2-6 10…150 Hz 5 gnResistance to electrostatic discharges

Conforming to IEC 01-2 Level 3 kV

Resistance to electromagnetic fields

Conforming to IEC 01-3 Level 3 ; 27…1000 MHz V/m 10

Resistance to rapid transients

Conforming to IEC 01-4 Level 3

On power supply kV 2On I/O kV 1

Resistance to shock waves

Conforming to IEC 947-1 Waveform 1.2/50 ms ; 0.5 J

U < 50 V kV 0.5U < 150 V kV 1.5U < 300 V kV 2.5

Cross-sections which may be connected

Flexible cable with no cable end 1 or 2-wire mm2 0.6…2.5Flexible cable with cable end 1 or 2-wire mm2 0.34…2.5Rigid cable 1-wire mm2 0.27…4

Operating position AnyAmbient air temperature around the device

Unrestricted operation °C - 5…+ 55Operation at Us °C - 25…+ 70Storage °C - 40…+ 0

Operating altitude m ≤ 300Installation category Conforming to IEC 947-1 IIDegree of pollution Conforming to IEC 947-1 2Mounting Standard rails 5 1 4

Characteristics

1

2

3

4

5

6

7

8

9

10

Page 68: Schneider Electric - Relay's Catalog Sept 09

66

Interfaces For discrete signalsSlim solid-state interface modules

Control circuit characteristics (55°C ambient temperature)Type of interface ABS

2EC01EAABS 2EC01EB

ABS 2EC01EE

ABS 2EA01EF

ABS 2EA02EF

ABS 2EA01EM

ABS 2EA02EM

Rated voltage Us c V 5 24 4 – – – –a V – – – 115/127

50 Hz120/127 60 Hz

230/240 50 Hz

230/240 60 Hz

Maximum voltage c V Negative logic 6 (TTL)

2. 57.6 – – – –

a V – – – 140 140 264 264Maximum current at Us c mA 13.6 12 10.5 – – – –

a mA – – – 14 17 12.5 15State 1 assured c V 3.75 16.9 36 – – – –

mA 4.5 7.7 7.5 – – – –a V – – – 6.3 90 173 173

mA – – – .4 9.7 7.9 9.3State 0 assured c V 2 5.6 10. – – – –

mA 0.09 2 2 – – – –a V – – – 25.4 25.4 4 4

mA – – – 2.5 2.5 2.5 2.5State 1 display Yes Yes Yes Yes Yes Yes YesInternal protection reversed polarity Yes Yes Yes – – – –

Output circuit characteristicsRated operating voltage Ue c V 5...4Min/max voltage c V 2/60Min/max current switched mA 1/50Maximum residual current at state 0 mA 0.1Maximum volt drop at state 1 V 1Internal protection Reversed polarityExternal protection Against short-circuits for Ik ≤ 100 A (c)

Quick-blow fuse, ref. : HA21 0.25 A or equivalent

Other characteristicsType of interface ABS

2EC01EAABS 2EC01EB

ABS 2EC01EE

ABS 2EA01EF

ABS 2EA02EF

ABS 2EA01EM

ABS 2EA02EM

Time delay characteristics Response time max Ue ≤ 30 V Ie ≥ 5 mA

0 V 1 ms 0.05 0.05 0.05 10 10 10 101 V 0 ms 0.4 0.4 0.4 20 20 20 20

Maximum switching rate Duty cycle 50 % Ue ≤ 30 V Ie ≥ 5 mA

Hz 1000 1000 1000 25 25 25 25

Rated insulation voltage Conforming to IEC 947-1 : 300 VConforming to VDE 0110 : 250 V group C

Insulation test voltage for 1 minute

I/O kVrms 4Wired interface/earth kVrms 2.5

Presentation:page 64

Characteristics:page 65

Curves:page 6

References:page 6

Dimensions, schemes:page 69

Presentation:page 64

Characteristics:page 65

Curves:page 6

References:page 6

Dimensions, schemes:page 69

Characteristics (continued)

1

2

3

4

5

6

7

8

9

10

Page 69: Schneider Electric - Relay's Catalog Sept 09

67

Interfaces For discrete signalsSlim solid-state interface modules

Control circuit characteristics (55°C ambient temperature)Type of interface ABS 2SC01EB ABS 2SC02EB ABS 2SA01MB ABS 2SA02MB

Rated voltage Us c V 24 24Maximum voltage V 2. 2.Maximum current at Us mA 12 13.6State 1 assured V 16.9 16.9

mA 7.7 .3State 0 assured V 5.6 5.3

mA 2 2State 1 display Yes YesInternal protection reversed polarity Yes Yes

Output circuit characteristicsRated operating voltage Ue V c 5...4 c 5...4 a 24...240 a 24...240Maximum voltage V c 57.6 c 57.6 a 264 a 264Maximum continuous current (Ith) (1) at 40 °C

A 2 3 2.3 3

Rated operating voltage (Ie) Conforming to IEC 947-5-1 Single/touching product at 55 °C vertical position

A DC12 1.5/0.9 2.5/2.2 AC12 1.9/0.5 2.1/1.5A DC13 1.5/0.9 2.5/2.2 AC13 1.6/0.5 1.6/1.5A DC14 0.6/0.6 0.6/0.6 AC14 1.6/0.5 1.6/1.5A – – – AC15 1/0.5 1/1

Minimum current c/a mA 1 10Maximum residual current c/a mA 1 2.5Maximum volt drop V 1.5 3 (Ie ≥ 10 mA)

1.5 (Ie ≥ 100 mA)“0 crossing” voltage V – 50 peakSolid-state dV/dt V/ms – 500Internal protection Reversed polarityExternal protection Against short-circuits for Ik ≤ 1 kA (a) and ≤ 100 A (c)

Quick-blow fuse with high breaking capacity: 3.15 A

Other characteristicsMaximum response time at Ie Š 10 mA

0 V 1 ms 0.05 10 (50 Hz) ; (60Hz)1 V 0 ms 0.6 10 (50 Hz) ; (60Hz)

Maximum switching rate At 55 °C ; at Ie: module alone duty cycle 40 %

Hz DC13 6 6 AC13 0.6 0.7Hz DC14 1 3 AC14 0.6 0.7Hz – – – AC15 0.6 0.7

On resistive load duty cycle 50 %

Hz 700 50

Rated operating voltage Conforming to IEC 947-1 : z 300 VConforming to VDE 0110 : 250 V group C

Rated Insulation voltage for 1 minute

I/O kVrms 4Wired interface/earth kVrms 2.5

(1) See temperature derating curves.(1) See temperature derating curves.

Characteristics (continued)

1

2

3

4

5

6

7

8

9

10

Page 70: Schneider Electric - Relay's Catalog Sept 09

6

Interfaces For discrete signalsSlim solid-state interface modules

Solid-state input modulesWidth Input circuit Output circuit Sold in

lots ofUnit reference

WeightCurrent Nominal voltage Current Nominal voltage

mm V V kg9.5 c 5 c 5…4 5 ABS 2EC01EA 0.029

24 c 5…4 5 ABS 2EC01EB 0.0294 c 5…4 5 ABS 2EC01EE 0.029

a 115…127 (50 Hz) c 5…4 5 ABS 2EA01EF 0.032120…127 (60 Hz) c 5…4 5 ABS 2EA02EF 0.032230…240 (50 Hz) c 5…4 5 ABS 2EA01EM 0.033230…240 (60 Hz) c 5…4 5 ABS 2EA02EM 0.033

Solid-state output modulesWidth Input circuit Output circuit Sold in

lots ofUnit reference

WeightCurrent Nominal voltage Current Nominal voltage

mm V A V kg9.5 c 24 c 2 24…4 5 ABS 2SC01EB 0.034

a 2.3 24…230 5 ABS 2SA01MB 0.03417.5 c 24 c 3 24…4 1 ABS 2SC02EB 0.043

a 3 24…230 1 ABS 2SA02MB 0.044

AccessoriesFor connecting commons, use ABF C08ppp flexible combs (Please consult your customer care centre).

Temperature derating curve for solid-state output modules Uc = Us = c 24 VABS 2SC01EB d.c. ABS 2SC02EB d.c.

ABS 2SA01MB a.c. ABS 2SA02MB a.c.

1 Vertical module alone or adjacent to modules with low heat dissipation.

2 Horizontal module alone or adjacent to modules with low heat dissipation.

3 Vertical module mounted with 2 modules with identical heat dissipation on both sides.

4 Horizontal module mounted with 2 modules with identical heat dissipation on both sides.

10 20 30 40 50 60 70

1

2

3

1/2

00

3/4

Ie (A)

T °C ambient10 20 30 40 50 60 70

1

2

3

1/2

00

3/4

Ie (A)

T °C ambient10 20 30 40 50 60 70

1

2

3

1/2

00

4

3

Ie (A)

T °C ambient10 20 30 40 50 60 70

1

2

3

1/2

00

4

3

Ie (A)

T °C ambient

10 20 30 40 50 60 70

1

2

3

1/2

00

3/4

Ie (A)

T °C ambient10 20 30 40 50 60 70

1

2

3

1/2

00

3/4

Ie (A)

T °C ambient10 20 30 40 50 60 70

1

2

31/2

00

4

3

Ie (A)

T °C ambient10 20 30 40 50 60 70

1

2

31/2

00

4

3

Ie (A)

T °C ambient

Presentation:page 64

Characteristics:page 65

Curves:page 6

References:page 6

Dimensions, schemes:page 69

Presentation:page 64

Characteristics:page 65

Curves:page 6

References:page 6

Dimensions, schemes:page 69

References, curves

1

2

3

4

5

6

7

8

9

10

Page 71: Schneider Electric - Relay's Catalog Sept 09

69

Interfaces For discrete signalsSlim solid-state interface modules

DimensionsABS 2E/ABS 2Sp01pp ABS 2Sp02pp

Circuit diagramsSolid-state input modulesABS 2ECpppp ABS 2EApppp ABS 2Epppp

Solid-state output modulesABS 2SC0pEB ABS 2SA0pMB ABS 2SC0pEB ABS 2SA0pMB

F: fuse DF1 SS133.2(1) or peak limiter

78

75

70,574

9,578

75

70,574

9,5 78

75

70,5

17,5

74

78

75

70,5

17,5

74

+A

1

–A2

+13 –14

+A

1

–A2

+13 –14

A

1

A

2

+13 –14

A

1

A

2

+13 –14

14

13

A2

A1

+ –

5…48 V

+ –14

13

A2

A1

+ –

5…48 V

+ –

+13

–14

+A1

–A2

+13

–14

+A1

–A2

1

3

1

4

+A

1

–A2

1

3

1

4

+A

1

–A2

1413

A2

A1

+ –

+ –

– F

5-24 V

Resistive load

1413

A2

A1

+ –

+ –

– F

5-24 V

Resistive load

1413

A2

A1

+ –

+ –

– F

5-24 V

(1)

Inductive load

1413

A2

A1

+ –

+ –

– F

5-24 V

(1)

Inductive load

1413

A2

A1

+ –

– F

5-24 V

Resistive load

1413

A2

A1

+ –

– F

5-24 V

Resistive load

1413

A2A1

+ –

– F

5-24 V

(1)

Inductive load

1413

A2A1

+ –

– F

5-24 V

(1)

Inductive load

Dimensions, schemes

1

2

3

4

5

6

7

8

9

10

Page 72: Schneider Electric - Relay's Catalog Sept 09

2

1

3

4

5

6

7

8

9

10

7070

Selection guide Zelio Relay - Solid State Relays SSR solid state relays

Applications Panel mounted 5 rail mounted

PF5

2606

2-32

-Q

Contact type 1 N/O SPST contact 1 N/O SPST contact

Control voltage ranges a 90…20 V 90…20 V 90…140 Vc 3…32 V 4…32 V 3…32 V

Operating voltages a 24…20 V, 4…530 V, 4…660 V

24…20 V

Type of switching a

Zero voltage switching Zero voltage switching

Current a

10, 25, 50, 75, 90, 125 A 10, 20, 30 A 45 A

Degree of protection IP20 IP20

LED indication Yes Yes

Cooling Thermal protection or with heat sink accessory Built-in heat sink

Solid state relay typeSSR P SSR D

Page 76 76

PF5

2606

0-24

-Q

Page 73: Schneider Electric - Relay's Catalog Sept 09

2

1

3

4

5

6

7

8

9

10

7171

Applications Panel mounted 5 rail mounted

PF5

2606

2-32

-Q

Contact type 1 N/O SPST contact 1 N/O SPST contact

Control voltage ranges a 90…20 V 90…20 V 90…140 Vc 3…32 V 4…32 V 3…32 V

Operating voltages a 24…20 V, 4…530 V, 4…660 V

24…20 V

Type of switching a

Zero voltage switching Zero voltage switching

Current a

10, 25, 50, 75, 90, 125 A 10, 20, 30 A 45 A

Degree of protection IP20 IP20

LED indication Yes Yes

Cooling Thermal protection or with heat sink accessory Built-in heat sink

Solid state relay typeSSR P SSR D

Page 76 76

PF5

2633

9-1

-Q

Page 74: Schneider Electric - Relay's Catalog Sept 09

2

1

3

4

5

6

7

8

9

10

7272

Presentation Zelio Relay - Solid State RelaysSSR solid state relays

PresentationThe SSR solid state relay range comprises:

relays for panel mounting: SSR P.relays for 5 rail mounting: SSR D.

bb

DescriptionSSR P relays for panel mounting

2 x Ø 4.5 holes for fixing.Connection terminals.Connection terminal screws.Input indicator LED, green.Thermal interface which must be via the back of the product.

1 2 3 4 5

SSR D relays for 5 rail mountingLugs for panel mounting.Integrated heat sink.Connection terminals.Connection terminal screws.Input indicator LED, green.Bracket for mounting on 5 rail.

1 2 3 4 5 6

Presentation : page 72

Characteristics : page 73

References : page 76

Dimensions : page 77

1

2

4

1

5

3

1

2

56

1

43

Page 75: Schneider Electric - Relay's Catalog Sept 09

2

1

3

4

5

6

7

8

9

10

7373

Characteristics Zelio Relay - Solid State RelaysSSR P solid state relays Panel mounting

General characteristicsProduct certifications UL E25297, CSA 1696Product marking e, IEC 60950Ambient air temperature around the device

Operation °C - 40…+ 0Storage °C - 40…+ 125

Encapsulation Thermally conductive epoxyDegree of protection IP20Terminal screw torque Nm

Inputs: 1.1 Outputs: 2.2

Relay type SCR output, Zero voltage switching SSR PCDS10A1 SSR PCDS25A1 SSR PCDS50A1Input specification

Control voltage range c V 3…32 3…32 3…32Minimum turn-on voltage c V 3 3 3Maximum turn-off voltage c V 1.0 1.0 1.0Typical input current mA 10 at c 12 V 10 at c 12 V 10 at c 12 V

Output specificationOperating voltage a V 24…20 24…20 24…20Load current range A 0.15 …10 0.15…25 0.15…50Transient overvoltage Vpk 600 600 600Maximum surge current (16.6 ms) Apk 120 250 625Maximum On-state voltage drop at rated current Vpk 1.6 1.6 1.6Thermal resistance junction to case °C/W 1.4 1.02 0.63Maximum I²t for fusing (8.3 ms) A²sec 60 260 1620Maximum off-state leakage current at rated voltage mA 1.0 1.0 1.0Minimum off-sate dv/dt at maximum rated voltage V/µsec 500 500 500Maximum turn-on time Cycle 1/2 1/2 1/2Maximum turn-off time Cycle 1/2 1/2 1/2

Relay type SCR output, Zero voltage switching SSR PCDS75A2 SSR PCDS90A3 SSR PCDS125A3Input specification

Control voltage range c V 4…32 4…32 4…32Minimum turn-on voltage c V 4 4 4Maximum turn-off voltage c V 1.0 1.0 1.0Typical input current mA 15 at c 5 V 15 at c 5 V 15 at c 5 V

Output specificationOperating voltage a V 4…530 4…660 4…660Load current range A 0.15…75 0.15…90 0.15…125Transient overvoltage Vpk 1200 1200 1200Maximum surge current (16.6 ms) Apk 1000 1200 1750Maximum On-state voltage drop at rated current Vpk 1.6 1.6 1.7Thermal resistance junction to case °C/W 0.31 0.2 0.22Maximum I²t for fusing (8.3 ms) A²sec 4150 6000 12 700Maximum off-state leakage current at rated voltage mA 10 1.0 1.0Minimum off-sate dv/dt at maximum rated voltage V/µsec 500 500 500Maximum turn-on time Cycle 1/2 1/2 1/2Maximum turn-off time Cycle 1/2 1/2 1/2

Page 76: Schneider Electric - Relay's Catalog Sept 09

2

1

3

4

5

6

7

8

9

10

7474

Characteristics (continued) Zelio Relay - Solid State RelaysSSR P solid state relaysPanel mounting

Relay type SCR output, Zero voltage switching SSR PP8S10A1 SSR PP8S25A1 SSR PP8S50A1Input specification

Operating voltage a V 90…20 90…20 90…20Minimum turn-on voltage Vrms 90 90 90Maximum turn-off voltage Vrms 10 10 10Typical input current mA 2 at 120 Vrms 2 at 120 Vrms 2 at 120 Vrms

Output specificationOperating voltage a V 24…20 24…20 24…20Load current range A 0.04…10 0.04…25 0.04…50Transient overvoltage Vpk 600 600 600Maximum surge current (16.6 ms) Apk 120 250 625Maximum On-state voltage drop at rated current Vpk 1.6 1.6 1.6Thermal resistance junction to case °C/W 1.4 1.02 0.63Maximum I²t for fusing (8.3 ms) A²sec 60 260 1620Maximum off-state leakage current at rated voltage mA …10 …10 …10Minimum off-sate dv/dt at maximum rated voltage V/µsec 500 500 500Maximum turn-on time Cycle 1/2 1/2 1/2Maximum turn-off time Cycle 1/2 1/2 1/2

Relay type SCR output, Zero voltage switching SSR PP8S75A2 SSR PP8S90A3 SSR PP8S125A3Input specification

Operating voltage a V 90…20 90…20 90…20Minimum turn-on voltage Vrms 90 90 90Maximum turn-off voltage Vrms 10 10 10Typical input current mA 2 at 120 Vrms 2 at 120 Vrms 2 at 120 Vrms

Output specificationOperating voltage a V 0…530 4…660 4…660Load current range A 0.04…75 0.04…90 0.15…125Transient overvoltage Vpk 1200 1200 1200Maximum surge current (16.6 ms) Apk 1000 1200 1750Maximum On-state voltage drop at rated current Vpk 1.7 1.7 1.7Thermal resistance junction to case °C/W 0.31 0.2 0.22Maximum I²t for fusing (8.3 ms) A²sec 4150 6000 12 700Maximum off-state leakage current at rated voltage mA 10 5 5Minimum off-sate dv/dt at maximum rated voltage V/µsec 500 500 500Maximum turn-on time Cycle 1/2 1/2 1/2Maximum turn-off time Cycle 1/2 1/2 1/2

Presentation : page 72

Characteristics : page 73

References : page 76

Dimensions : page 77

Page 77: Schneider Electric - Relay's Catalog Sept 09

2

1

3

4

5

6

7

8

9

10

7575

Characteristics Zelio Relay - Solid State RelaysSSR D solid state relay5 rail mounting

General characteristicsProduct certifications UL E25297, CSA 1696Product marking e, IEC 60950Ambient air temperature around the device

Operation °C - 40…+ 0Storage °C - 40…+ 125

Encapsulation Thermally conductive epoxyDegree of protection IP20Terminal screw torque 10…30 A relays Nm Inputs: 0.6…0.7

Outputs: 0.6…0.745 A relays Nm

Inputs: 0.6…0.7 Outputs: 1.1…1.7

Relay type SCR output, Zero voltage switching SSR DP8S10A1 SSR DP8S20A1 SSR DP8S30A1 SSR DF8S45A1Input specification

Operating voltage a V 90…20 90…20 90…20 90…140Minimum turn-on voltage Vrms 90 90 90 90Maximum turn-off voltage Vrms 10 10 10 10Typical input current mA

2 (120 Vrms), 4 (240 Vrms)

2 (120 Vrms), 4 (240 Vrms)

2 (120 Vrms), 4 (240 Vrms)

15 (120 Vrms)

Output specificationOperating voltage a V 24…20 24…20 24…20 24…20Load current range A 0.15…10 0.15…20 0.15…30 0.15…45Transient overvoltage Vpk 600 600 600 600Maximum surge current (16.6 ms) Apk 120 250 625 625Maximum On-state voltage drop at rated current Vpk 1.6 1.6 1.6 1.6Maximum I²t for fusing (8.3 ms) A²sec 60 260 1620 1620Maximum off-state leakage current at rated voltage mA 10 10 10 10Minimum off-sate dv/dt at maximum rated voltage V/µsec 500 500 500 500Maximum turn-on time Cycle 1/2 1/2 1/2 1/2Maximum turn-off time Cycle 1/2 1/2 1/2 1/2

Relay type SCR output, Zero voltage switching SSR DCDS10A1 SSR DCDS20A1 SSR DCDS30A1 SSR DCDS45A1Input specification

Control voltage range c V 4…32 4…32 4…32 3…32Minimum turn-on voltage c V 4.0 4.0 4.0 4.0Maximum turn-off voltage c V 1.0 1.0 1.0 1.0Typical input current mA …12 …12 …12 17

Output specificationOperating voltage a V 24…20 24…20 24…20 24…20Load current range A 0.15…10 0.15…20 0.15…30 0.15…45Transient overvoltage Vpk 600 600 600 600Maximum surge current (16.6 ms) Apk 120 250 625 625Maximum On-state voltage drop at rated current Vpk 1.6 1.6 1.6 1.6Maximum I²t for fusing (8.3 ms) A²sec 60 260 1620 1620Maximum off-state leakage current at rated voltage mA 10 10 10 10Minimum off-sate dv/dt at maximum rated voltage V/µsec 500 500 500 500Maximum turn-on time Cycle 1/2 1/2 1/2 1/2Maximum turn-off time Cycle 1/2 1/2 1/2 1/2

Page 78: Schneider Electric - Relay's Catalog Sept 09

2

1

3

4

5

6

7

8

9

10

7676

References Zelio Relay - Solid State RelaysSSR solid state relays

Solid state relays, 1 N/O SPST contactPanel mountingb

Switching Voltage range Load current range

References WeightInput Output

V V A kgSCR output

Zero voltage switching

c 3…32 a 24…20 10 SSR PCDS10A1 0.113

25 SSR PCDS25A1 0.113

50 SSR PCDS50A1 0.113

c 4…32 a 4…530 75 SSR PCDS75A2 0.113

a 4…660 90 SSR PCDS90A3 0.113

125 SSR PCDS125A3 0.113

a 90…20 a 24…20 10 SSR PP8S10A1 0.113

25 SSR PP8S25A1 0.113

50 SSR PP8S10A1 0.113

a 0…530 75 SSR PP8S75A2 0.113

a 4…660 90 SSR PP8S90A3 0.113

125 SSR PP8S125A3 0.113

5 rail mounting bSCR output

Zero voltage switching

a 90…20 a 24…20 10 SSR DP8S10A1 0.272

20 SSR DP8S20A1 0.272

30 SSR DP8S30A1 0.272

a 90…140 a 24…20 45 SSR DF8S45A1 0.42

c 4…32 a 24…20 10 SSR DCDS10A1 0.272

20 SSR DCDS20A1 0.272

30 SSR DCDS30A1 0.272

c 3…32 a 24…20 45 SSR DCDS45A1 0.42

Accessories for panel mounted relaysDescription For use with relays Unit references Weight

kgHeat sink SSR PPSpppp,

SSR PCDSppppSSR AH1 0.47

Thermal interfaceSold in lots of 10

SSR PPSpppp, SSR PCDSpppp

SSR AT1 0.011

SSR AT1

PF5

2606

4-2

-Q

SSR PCDS25A1

PF5

2606

0-24

-Q

SSR DCDS10A1

PF5

2633

9-1

-Q

SSR DCDS45A1

PF5

2606

2-32

-Q

SSR AH1

PF5

2606

3-50

-Q

Presentation : page 72

Characteristics : page 73

References : page 76

Dimensions : page 77

Page 79: Schneider Electric - Relay's Catalog Sept 09

2

1

3

4

5

6

7

8

9

10

7777

Dimensions Zelio Relay - Solid State RelaysSSR solid state relays

Solid state relays, 1 N/O SPST contactPanel mountingb

Solid state relays SSR P Thermal interface SSR AT1

35,547,1

45,5

= =

58,4

47,3

Ø4,5

47,7

4,6

55,1

42,4

Heat sink SSR AH1

115,8

66

120,6139,7114,3

4,6 4,6

5 rail mounting b10…30 A relays 45 A relays

22,5

98,8 80 89,7

11,2(1)

97,7

Ø4,4 Ø4,4

22,6

106,7

45,513,15

(1)

98,8

76,2

87,4

(1) Ø 4.4 x 5.5 elongated hole (1) Ø 4.4 x 5.5 elongated hole

Page 80: Schneider Electric - Relay's Catalog Sept 09

Software toolsMotion control

Power supplies

Mounting systems

Interfaces & I/O

HMIs

Detection

AutomationMotor control

Networks & Communication

Schneider Electric products provide quality solutions, meeting all your Automation and Control applications requirements.

A worldwide presence• More than 5,000 points of sale in 130 countries.

• A range of products that meet the standards of the country in which they will be used.

Canadian support• Over 100 dedicated sales engineers operate from multiple regional sales and technical service centres accross Canada.

• Our sales engineers are skilled at assessing individual requirements. Combined with the expert support of our product specialists, they will develop the most effective and economical solution for you, taking relevant regulations and standards into account.

www.schneider-electric.caCustomer Service: (800) 565-6699

© 2

009

Schn

eide

r Can

ada

Inc.

All R

ight

s Res

erve

d.

September 2009

Schneider Electric

19 Waterman AvToronto, Ontario M4B 1Y2

S8009CT0901EP R0