schematic lighting design

24
Schematic Lighting Design Natty Boh Building Baltimore , Maryland Eric Singley Penn State University Architectural Engineering

Upload: judith-england

Post on 30-Dec-2015

36 views

Category:

Documents


0 download

DESCRIPTION

Schematic Lighting Design. Natty Boh Building Baltimore , Maryland. Eric Singley Penn State University Architectural Engineering. Location. Natty Boh Building. Brewers Hill Baltimore , Maryland. Penn State AE. Schematic Lighting Proposal. Eric Singley. Project Information. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Schematic Lighting Design

Schematic Lighting Design

Natty Boh Building

Baltimore , Maryland

Eric Singley

Penn State University

Architectural Engineering

Page 2: Schematic Lighting Design

Location Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Brewers Hill

Baltimore , Maryland

Page 3: Schematic Lighting Design

Project Information

Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Building Statistics:

Overall Building Size : 189,550 ft2.

Maximum Height : 9 stories

Multi-purpose: office, storage, residential, commercial

Building Character:

Old home of the Gunther Brewing Company.

Consists of 6 sections of differing heights.

Declared a historic place in 2002.

Page 4: Schematic Lighting Design

Design Spaces Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Large Work Space

Friday’s Day Care Center

Circulation Space

Canton Self Storage Lobby

Outdoor Space

Parking lot and rear facade

Special Purpose Space

Countrywide conference room

Page 5: Schematic Lighting Design

Day Care Center

Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Space Properties

Floor area 4092 ft2.

Exposed ceiling at 14 ft.

Large windows on east and

west walls.

Interior partitions dividing

kitchen and storage areas.

Space Tasks

Primarily play and learning

area for small children.

Light kitchen use.

Page 6: Schematic Lighting Design

Day Care Center

Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Page 7: Schematic Lighting Design

Day Care Center

Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Design Goals

Separate the spaces by function with lighting.

Create a more ‘playful’ atmosphere within the child care area.

Make use of the large windows to introduce daylighting to the space.

Flynn mode – Relaxed.

Power Density

1.5 Watts per square foot allowed.

Page 8: Schematic Lighting Design

Day Care Center

Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Design Solution

Drop ceiling to 9’.

Recessed linear fluorescent

downlights in walkways.

Recessed CFL downlights in

childrens’ area and kitchen.

Under-cabinet lights in kitchen.

LED color spots on columns.

Page 9: Schematic Lighting Design

Day Care Center

Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Daylight Integration

Kitchen lights and window-

side children’s are lights on

their own circuit. Use

Photometric sensor with

manual override for control.

Page 10: Schematic Lighting Design

Lobby Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Space Properties

Floor Area ≈ 2500 ft2

Ceiling at 8 ft and 21.5 ft

No windows

Entrances on both levels

Space Tasks

Light office work

Display of model storage unit

Sales / Receptionist desks

Page 11: Schematic Lighting Design

Lobby Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Page 12: Schematic Lighting Design

Lobby Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Design Goals

Accentuate the double height ceiling.

Direct customers from entrances to the sales desk.

Provide a non-complex design solution.

Flynn mode – Spacious.

Power Density

1.3 Watts per square foot allowed.

Page 13: Schematic Lighting Design

Lobby Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Page 14: Schematic Lighting Design

Lobby Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Design Solution

CFL downlights over desks.

Recessed CFL downlights in 9’6” portion lower ceiling.

Linear fluorescent wallwash along open wall.

Wallwashers on 21 ft walls to accent their height.

Page 15: Schematic Lighting Design

Conference Room

Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Space Properties

Floor Area : 150 ft2

Ceiling at 8 ft

Conference table with chairs

No windows

Space Tasks

Professional and Casual

conferences

Possible light video

conferencing

Page 16: Schematic Lighting Design

Conference Room

Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Page 17: Schematic Lighting Design

Conference Room

Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Design Goals

Create a comfortable yet professional environment.

Provide flexibility to accommodate different uses. Including:

Presentations

Video conferencing

Roundtable discussion

Flynn mode – Spacious/Focused

Power Density

1.5 Watts per square foot allowed

Page 18: Schematic Lighting Design

Conference Room

Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Roundtable Discussion

Recessed CFL downlights on the

conference table.

Linear Fluorescents washing walls

and ceiling to provide ambient lighting.

Page 19: Schematic Lighting Design

Conference Room

Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Presentation

Ambient lighting remains on.

Reduce the number of downlights

on the conference table.

Two spot lamps on podium.

Page 20: Schematic Lighting Design

Conference Room

Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Video Conferencing

Dimmed ambient lighting.

Spot lamps on individual faces.

Downlights on table reduced further.

Page 21: Schematic Lighting Design

Exterior Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Space Properties

Ground Area : 37,050 ft2

Surrounded on 3 sides by buildings

Historically significant

Space Tasks

Parking for Natty Boh Building

Entrance to the building

Page 22: Schematic Lighting Design

Exterior Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Page 23: Schematic Lighting Design

Exterior Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Design Goals

Provide sufficient light to allow drivers to read signs and see parking lines.

Call attention to the building entrances.

Achieve 100% Dark Sky compliance.

Maintain similar luminaire appearance.

Power Density

0.3 Watts per square foot allowed

Page 24: Schematic Lighting Design

Exterior Natty Boh Building

Penn State AE Eric SingleySchematic Lighting Proposal

Design Solution

Spotlight building entrances.

Prevent spill into windows.

Keep light poles on existing

islands.