scandmist 350d oil mist filtration system
TRANSCRIPT
Leadership in Filtration
ScandMist 350DOil mist filtration system
2
ScandMist 350DOil mist filtration system
General Product Units ScandMist 350D
Application Oil Mist
Capacity (nominal) m3/h 6000
Part number A1D35DF000010A
Connections Inlet type Jacobs
Inlet diameter mm 350
Drain 2 off, 2” Threaded (BS 21) Female
Air inlet options Left
Exhaust Backwards
Filters Filters/stage 1
Stage 1 filter 97090M1610
Stage 2 filter 97090M2088
Stage 3 filter 800527034779
Available external pressure drop Pa 500
Motor Type IE3
Part number 9708900046
Quantity 1
Mains supply 3 ~ 380–480 V, 50/60 Hz
Ventilation TEFC
Power kW 11
Maximum current A 20.5
Speed RPM Max 2955
Environmental protection IP55
Physical properties Width mm 1236
Height mm 4042
Depth mm 1122
Weight kg Clean filters: 869, Wet filters: 938
Noise level dB(A) <69
Fan Backward bent blades
Finish Powder coating inside and outside
Controls Control system Frequency inverter FC102 + Micatrone MF-PFA
Differential pressure gauges 3 off
Options Oil pump 9708900065
Level sensor 99089000187
Prefilter demister 2500273209
Spray Not included
Silencer Not included
3
Dimensions and weightUnits: mm
Weight kg
Empty 605 kg
Clean filters 264 kg
Wet filters 333 kg
3393
2396 4042
555
1122
1236950864
1106
1056
352
3393
2396 4042
555
1122
1236950864
1106
1056
352
IE3 fan and motor
IE3 configuration takes performance to the next level with exceptionally low energy consumption.
To the frequency converter
L1 L2 L3 PE Main power supply
ON/OFF (24 VDC) S1 -Switch
Volt (+)
GND (-) 0 – 10 V Output 1 signal from Micatrone MF-PFA
From the frequency converter
U V W PE To the motor
AI M Motor temperature
G (+) G0 (-) 24 VDC for Micatrone MF-PFA
From the Micatrone MF-PFA
13 from S1 14 (M) Alarm 1, high/low/operating signal
16 from S1 17 (M) Alarm 2, high/low/operating signal
11 12 S2 -Reset of Alarm 1+2
Fan
pres
sure
(Pa
)
2000 4000 800060000
2500
2000
1500
1000
500
0
5000
∆p_t4500
4000
3500
3000
10000
5
4
3
2
1
0
10
P_m9
8
7
6
Air flow (m3/h)
Pow
er (
kW)
MicatroneMF-PFA
S1ON/OFF24 VDC
Di�erential pressureP1P2
24 VDC / Output 1, 0 to 10 VG (+) G0 (-) / Volt (+) Ground (-)
L1 L2 L3 PE3-phase power supply400 V AC, 50 Hz
Frequency converter Micatrone
MF-PFA
Alarm 1
Al/M for motor temperature
Alarm 2
Alarm 1 Alarm 2
U V W PE
S2 reset for alarm 1+2
airfiltration.mann-hummel.com
04
19 P
rin
ted
in
Ge
rma
ny
© M
AN
N+
HU
MM
EL