sc-stm virtual tour · main boiler dimensions are editable for the steam master is based on hd dl...

18
Thermoflow Inc. What is STEAM MASTER S MASTER WHAT IS STEAM MASTER? While STEAM PRO is the design program for conventional steam cycle plants, STEAM MASTER is the associated simulation program for off-design calculations. Use STEAM MASTER to evaluate designs at various ambient conditions and loads. All STEAM MASTER hardware inputs has automatically been initialized based on the design, which makes it possible to perform calculations by just changing a few parameters. Since STEAM MASTER hardware inputs are editable, the model may be fine tuned to match an existing plant or vendor data. In combination with PEACE (Plant Engineering and Construction Estimator), STEAM MASTER provides engineering details and cost estimation. http://www.Thermoflow.ir

Upload: others

Post on 12-Mar-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SC-STM Virtual Tour · Main boiler dimensions are editable for the STEAM MASTER is based on hd dl ith ditbl i ... (previous ASME standard from 1967) IAPWS-IF97 ( t ASME t d d f 1997)IF97

Thermoflow Inc.

What is STEAM MASTERS MASTERWHAT IS

STEAM MASTER?

While STEAM PRO is the design program for conventional steamcycle plants, STEAM MASTER is the associated simulation program foroff-design calculations.

Use STEAM MASTER to evaluate designs at various ambient conditions and loads.g

All STEAM MASTER hardware inputs has automatically been initialized based on the design,which makes it possible to perform calculations by just changing a few parameters.

Since STEAM MASTER hardware inputs are editable, the model may be fine tuned to matchan existing plant or vendor data.

In combination with PEACE (Plant Engineering and Construction Estimator), STEAM MASTERprovides engineering details and cost estimation.

http://www.Thermoflow.ir

Page 2: SC-STM Virtual Tour · Main boiler dimensions are editable for the STEAM MASTER is based on hd dl ith ditbl i ... (previous ASME standard from 1967) IAPWS-IF97 ( t ASME t d d f 1997)IF97

STEAM MASTER

Load existing STEAM MASTERfile or import STEAM PRO file.

ST MASTER

Activating the STEAM MASTER programwill display this input screen for selectingthe desired file.

All STEAM MASTER models are based on aAll STEAM MASTER models are based on aSTEAM PRO design.

STEAM MASTER will allow the user to dooff-design calculations, such as part loadand varying ambient conditions.and varying ambient conditions.

http://www.Thermoflow.ir

Page 3: SC-STM Virtual Tour · Main boiler dimensions are editable for the STEAM MASTER is based on hd dl ith ditbl i ... (previous ASME standard from 1967) IAPWS-IF97 ( t ASME t d d f 1997)IF97

STEAM MASTERThe image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again.

At any time during the session the user canpress compute to activate the calculation.

ST MASTER

All the main topics arearranged horizontally to

The user may goback to STEAM PROto redesign the

“Green” topicsare available forPEACE licensesarranged horizontally to

underline the fact that,contrary to design inSTEAM PRO, off-design inSTEAM MASTER has no

t l d f diti

to redesign theplant if necessary.

PEACE licensesonly, and theirinputs primarilyimpacts the costcalculations.

natural order of editingthe topics.

The input screens apply graphicaldisplays to ease the use of the program.

http://www.Thermoflow.ir

Page 4: SC-STM Virtual Tour · Main boiler dimensions are editable for the STEAM MASTER is based on hd dl ith ditbl i ... (previous ASME standard from 1967) IAPWS-IF97 ( t ASME t d d f 1997)IF97

STEAM MASTER

Confirm actual

ST MASTER

Confirm actualambient conditions.

Select the appropriateplant control parameter.

Adjust fuel input forpart load calculations.

http://www.Thermoflow.ir

Page 5: SC-STM Virtual Tour · Main boiler dimensions are editable for the STEAM MASTER is based on hd dl ith ditbl i ... (previous ASME standard from 1967) IAPWS-IF97 ( t ASME t d d f 1997)IF97

STEAM MASTER Each main topic holds a set of input tabs for sub topics related to themain topic. E.g. highlighted main topic is Steam Turbine. Sub-topics ofthe Steam Turbine are ST Controls, Stage Groups & Controls, etc.

ST MASTER

Set desired pressureand temperature forth t l

Each sub-topic tab letsthe user set inputs forthat specific sub topic.

Select the appropriate steam turbine control method

the controls.

Select the appropriate steam turbine control method.

http://www.Thermoflow.ir

Page 6: SC-STM Virtual Tour · Main boiler dimensions are editable for the STEAM MASTER is based on hd dl ith ditbl i ... (previous ASME standard from 1967) IAPWS-IF97 ( t ASME t d d f 1997)IF97

STEAM MASTERST MASTER

Main boiler dimensionsare editable for the

STEAM MASTER is based on h d d l ith dit bl i

are editable for theuser to input data.

hardware models with editable sizeand dimensions. This allows theuser to adjust values to match anexisting plant or a vendor’s data.

Since STEAM MASTER appliesSince STEAM MASTER applieshardware models the heat balancecalculations will reflect any changein the hardware.

Cost of the plant will also beCost of the plant will also berecalculated taking the changesinto account.

http://www.Thermoflow.ir

Page 7: SC-STM Virtual Tour · Main boiler dimensions are editable for the STEAM MASTER is based on hd dl ith ditbl i ... (previous ASME standard from 1967) IAPWS-IF97 ( t ASME t d d f 1997)IF97

STEAM MASTER

Selection of different materialsDifferent fin-tube types il bl B S lid

ST MASTER

is available as well.are available: Bare, Solidfins and Serrated fins.

A pulldown listallows forselection

Even details of tubebundle design such

t b l th of the desiredelementof theboiler.

as tube length,bundle width,number of rowsand tube diametermay be edited. boiler.y

This flexibilityallows the user tomatch known plantdata.

Graphical displays help theuser visualising the tubeand tube bundle geometry.

Economiser (ECO) has beenselected as example.

http://www.Thermoflow.ir

Page 8: SC-STM Virtual Tour · Main boiler dimensions are editable for the STEAM MASTER is based on hd dl ith ditbl i ... (previous ASME standard from 1967) IAPWS-IF97 ( t ASME t d d f 1997)IF97

STEAM MASTER

Common unit systemsf d th ld

ST MASTER

from around the worldare supported by STEAM MASTER.

Compute will activatethe calculation engineand (after convergence)display the outputsfrom the calculation.

Also the steam property formulation may be selected.

Available formulations:

Thermoflow Proprietary (STQUIK)

IFC-67 (previous ASME standard from 1967)

IAPWS IF97 ( t ASME t d d f 1997)IAPWS-IF97 (current ASME standard from 1997)

http://www.Thermoflow.ir

Page 9: SC-STM Virtual Tour · Main boiler dimensions are editable for the STEAM MASTER is based on hd dl ith ditbl i ... (previous ASME standard from 1967) IAPWS-IF97 ( t ASME t d d f 1997)IF97

STEAM MASTERThe image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again.

ST MASTER

Output is displayed in three groups: Graphics (graphicaldisplay of thermodynamic results), Text (text and tables ofsame), and PEACE (size, weights and cost).), ( , g )

Each topic holds a large number of tabs each describing partof the plant results.

Plant Summarydisplays themain output.main output.Details can befound on thesubsequenttabs.

http://www.Thermoflow.ir

Page 10: SC-STM Virtual Tour · Main boiler dimensions are editable for the STEAM MASTER is based on hd dl ith ditbl i ... (previous ASME standard from 1967) IAPWS-IF97 ( t ASME t d d f 1997)IF97

STEAM MASTERThe image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again.

ST MASTER

Detailed results for the steam turbine displaying steam conditionsat the steam turbine inlets and conditions of all extractions.

Desired values are met through the STcontrol (MVL) and boiler control (sprays).

http://www.Thermoflow.ir

Page 11: SC-STM Virtual Tour · Main boiler dimensions are editable for the STEAM MASTER is based on hd dl ith ditbl i ... (previous ASME standard from 1967) IAPWS-IF97 ( t ASME t d d f 1997)IF97

STEAM MASTERAt any time the user maygo back to edit the inputs.

ST MASTER

Text display of the outputsText display of the outputsis organized in a way togive the user both a goodoverview and detailedinformation about theplant performance.

Pl t S illPlant Summary willgive the main plantdata, whereas thesubsequent tabs willdisplay more detailedp yinformation.

http://www.Thermoflow.ir

Page 12: SC-STM Virtual Tour · Main boiler dimensions are editable for the STEAM MASTER is based on hd dl ith ditbl i ... (previous ASME standard from 1967) IAPWS-IF97 ( t ASME t d d f 1997)IF97

STEAM MASTERThe image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again.

Multiple runs may be performed applying the ThermoflowMacro for studies of parameter variations.

ST MASTER

The Tables tab holds data for allthe components in the plant asthe components in the plant asseen on the left.

By highlighting the desired plantcomponent, data for thatcomponent will be displayedcomponent will be displayed.

Note that some of thecomponents are characterized byabbreviations, e.g. FWH is feedwater heater ECO is economiserwater heater, ECO is economiser,CS is convective superheater andWCC is water cooled condenser.

Furthermore a table describingthe fuel and a table with steamthe fuel and a table with steamcycle streams are available.

Each table can be saved as a.CSV file, which can be loadedinto Excel.into Excel.

http://www.Thermoflow.ir

Page 13: SC-STM Virtual Tour · Main boiler dimensions are editable for the STEAM MASTER is based on hd dl ith ditbl i ... (previous ASME standard from 1967) IAPWS-IF97 ( t ASME t d d f 1997)IF97

STEAM MASTERThe image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again.

ST MASTER

Schematics showing the main components in the plantSchematics showing the main components in the plantare selected through a Schematics List. Examples are:Site Plan, Boiler, Steam turbine (as shown), Condensers,Cooling towers, Feed-water heaters and pumps.

Displayed is theelevation view ofthe steam turbine.

HP turbine

IP turbine

Two double-flowLP turbines

Generator

Steam turbinemain dimensions

http://www.Thermoflow.ir

Page 14: SC-STM Virtual Tour · Main boiler dimensions are editable for the STEAM MASTER is based on hd dl ith ditbl i ... (previous ASME standard from 1967) IAPWS-IF97 ( t ASME t d d f 1997)IF97

STEAM MASTERIf the selected equipment (in this case Steam Turbine) holds sub-elements,each of those elements will have equipment data tables of their own.

ST MASTER

Each tab represents amajor part of the powermajor part of the powerplant. Selected for displayis the steam turbine.

The tables will displaydetailed information aboutsizes and weight of theselected element or groupof elements of the plant.

http://www.Thermoflow.ir

Page 15: SC-STM Virtual Tour · Main boiler dimensions are editable for the STEAM MASTER is based on hd dl ith ditbl i ... (previous ASME standard from 1967) IAPWS-IF97 ( t ASME t d d f 1997)IF97

STEAM MASTER

Project Cost Summary is displaying the total cost of

Cash Flow will tell the user howthe economy throughout thelifetime of the plant will be.

ST MASTER

p y gthe power plant.

Each tab represents a part of the total cost of

Reference cost is thecost at a reference

the power plant.Selected for display isthe SpecializedEquipment.

h bl ll d l

US Site, whereasEstimated cost is thecost at the actualsite.

The tables will displaydetailed informationabout equipment andlabor cost.

http://www.Thermoflow.ir

Page 16: SC-STM Virtual Tour · Main boiler dimensions are editable for the STEAM MASTER is based on hd dl ith ditbl i ... (previous ASME standard from 1967) IAPWS-IF97 ( t ASME t d d f 1997)IF97

STEAM MASTERThe image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again.

Thermoflow Macro enables the user to performseries of calculations in an easy and fast way.

ST MASTER

Part load calculations with constant ambient conditions.

Inputs to vary in themacro may be selectedmacro may be selectedfrom an extensive listof inputs availablefrom STEAM MASTER.

Full load calculations with varyingsite cooling water temperature.

http://www.Thermoflow.ir

Page 17: SC-STM Virtual Tour · Main boiler dimensions are editable for the STEAM MASTER is based on hd dl ith ditbl i ... (previous ASME standard from 1967) IAPWS-IF97 ( t ASME t d d f 1997)IF97

STEAM MASTERThe image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again.

Summary displays a fixedlist of main output data.

ST MASTER

Any of the general tabs allows theuser to define which data (outputsas well as inputs) to display in thatspecific table.

All tables can be exported to Exceld l d f l fdirectly or saved as a .CSV file forlater load into Excel.

Plots can be created.As an example Plantnet efficiency vs. Fuelinput.

For each case STEAM MASTERoutput can be displayed.

input.

http://www.Thermoflow.ir

Page 18: SC-STM Virtual Tour · Main boiler dimensions are editable for the STEAM MASTER is based on hd dl ith ditbl i ... (previous ASME standard from 1967) IAPWS-IF97 ( t ASME t d d f 1997)IF97

STEAM MASTERThe image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again.

Please contact Thermoflow for further

ST MASTER

Please contact Thermoflow for further information.

THERMOFLOW INCTHERMOFLOW, INC.

2 Willow St., STE 100

S thb h MA 01776Southborough, MA 01776

USA

Tel: +1-508-303-5033

Fax: +1-508-303-5022

E-mail: [email protected]

http://www.Thermoflow.ir