sbc ( symmetrix business class)
DESCRIPTION
ssssTRANSCRIPT
SBC ( Symmetrix Business class)
Mahesh
SBC Introduction Called as Alicanto and new symm naming convention is Vmax
10K. 4 engine max system configuration i.e. 8 directors. Two flavors available , Fab less and fabric. Single engine is called fabless as we it does not require MIBE. Multi engine is called fabric system i.e. online up gradation of
engines by using MIBE( second engine always have MIBE and other will be connected to it).
Engine and drives present on the same bay and can have daisy chained bay .
Up to 64 DAEs ( 16 per engine). 6 DIMMs present for each engine.
SBC Engine layout Argonaut engine: Both the directors are next to
each other not as one on the top of other (Vmax 1).
Each engine has two power supplies and a management module.
Each director has I/O modules ( Front and back end).
Each director has management module.
Front view
Director X Director Y
4 Power Supplies with integrated Fans
Rear View
I/O Modules I/O Modules
Director Y Director X
Management Module (Akula)
Management Module (Akula)
SBC : 1 engine , 60 drive config
Engine 1: Dir 1 & 2
SPS Modules for 1st 4 Vault DAE
SPS Modules Engine
No support for CKD DAE and directors present on the same bayDAE will be added in number of4.First 4 DAE are vault DAE.No battery support for non-vault DAE(immediate vault on power loss).Up to 16DAE and each DAE supports 15 drives so total of 240 drives.The diagram shows 1 Engine 60 drive configuration.
SBC : Adding DAEsDAE
DAE
DAE
DAE
Vault DAE
Vault DAE
Empty
Argonaut
Cable Manager
SERVER
UPS
2.2 KW SPS
DAE
DAE
Vault DAE
Vault DAE
2.2 KW SPS
First chunk of DAE
First chunk of DAE
Second chunk of DAE
Second chunk of DAE
Empty
DAE
DAE
DAE
DAE
DAE
DAE
Empty
Third chunk of DAE
Third chunk of DAE
Fourth chunk of DAE
SBC : MIBE
MIBE
SBC : 4 bay max config(960 drive)
Bolted together using Copper Cables
10 Meter Dispersion using Optical Cables
SBC : Engine components
Rear View
Management Module B
Spar
tan
or G
lact
an
A0, A
1,B0
,B1
BEAuro
raFa
bric
A
Fabr
ic
B
Spar
tan
or G
lact
an
C0, C
1,D0
,D1
BE
Spar
tan
or G
lact
an
A0, A
1,B0
,B1
BEAuro
raFa
bric
A
Fabr
ic
B
Spar
tan
or G
lact
an
C0, C
1,D0
,D1
BE
Management Module A
Director 2
I/OModule 0
I/OModule 2
I/OModule 3
I/OModule 4
I/OModule 1
I/OModule 0
I/OModule 2
I/OModule 3I/O
Module 4I/OModule 1
I/O Module 0 SIB ( system interface board) . I/O Module 1 & I/O Module 2 Backend slices , 1 controls A&B ,2 controls C&D. I/O Module 3 & I/O Module 4 Front end slices , 3 controls E&F , 4 controls G & H.
Director 1
SBC : Front end configs
IO MODULE3
IO MODULE4
IO MODULE3
IO MODULE4
SE or FA or FE or combination of these emulations.
SE or FA or FE or combination of these emulations.
FE is FCoE . Fibre Channel over Ethernet (FCoE): Fibre Channel over Ethernet, FCoE is a proposed standard for using the Fibre Channel protocol over Ethernet networks. FCoE enables SAN traffic to be natively transported over Ethernet networks, while protecting and extending the investment that enterprises have made in storage networks.
SBC : Front end configs(continued..) All front ends are FA.
Glac
ier
E0
E1
F0
F1
Glac
ier
G0
G1
H0
H1
Glac
ier
E0
E1
F0
F1
Glac
ier
G0
G1
H0
H1
All front ends are SE.
Qui
ckSa
nd
E0F0
Qui
ckSa
ndG0
H0
Qui
ckSa
nd
E0F0
Qui
ckSa
ndG0
H0
EVEN DIR
ODD DIR
EVEN DIR
ODD DIR
SBC : Front end configs(continued..) All front ends are FE.
Mixed SE and FE.
Heat
Wav
e
E0F0
EVEN DIR
ODD DIR
EVEN DIR
ODD DIR
Heat
wav
e
G0
H0
Heat
wav
e
E0
F0
Heat
wav
e
G0
H0
Heat
wav
e
E0
F0
Heat
wav
e
G0
H0
Heat
Wav
e
E0F0
Heat
wav
e
G0
H0
SBC : Front end configs(continued..) Mixed SE and FA.
Mixed FA and FE.
EVEN DIR
ODD DIR
EVEN DIR
ODD DIR
Glac
ier
E
0
E1
F0
F1
Qui
ckSa
ndG0
H0
Glac
ier
E
0
E1
F0
F1
Qui
ckSa
ndG0
H0
Glac
ier
E0
E1
F0
F1
Heat
wav
e
G0
H0
Glac
ier
E0
E1
F0
F1
Heat
wav
e
G0
H0
Argonaut director
DIMMs
Argonaut CPU
Diff between V1 and SBC 6 DIMMs only (8 in V1) Single phase power only. Same rules as Drive Bay Dispersion in V-Max V1. No mainframe support. No battery backup for non-vault DAE.