sata digital device moi jdsu utd1.4 1.00

87
Serial ATA Logo Group 1 Digital MOI for JDSU Xgig Test Platform 15 October 2009 Version 1.00 Serial ATA Interoperability Program Revision 1.4 JDSU MOI for Device Digital Tests (ASR, GTR, NCQ, SSP, IPM and DOF) This document is provided "AS IS" and without any warranty of any kind, including, without limitation, any express or implied warranty of noninfringement, merchantability or fitness for a particular purpose. In no event shall SATAIO or any member of SATAIO be liable for any direct, indirect, special, exemplary, punitive, or consequential damages, including, without limitation, lost profits, even if advised of the possibility of such damages. This material is provided for reference only. The Serial ATA International Organization does not endorse the vendor’s equipment outlined in this document

Upload: others

Post on 08-Jan-2022

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  1  Digital MOI for JDSU Xgig Test Platform  

15 October 2009 Version 1.00  Serial ATA Interoperability Program Revision 1.4 JDSU MOI for Device Digital Tests (ASR, GTR, NCQ, SSP, IPM and DOF)

This document  is provided "AS IS" and without any warranty of any kind,  including, without  limitation, any express or implied warranty of non‐infringement, merchantability or fitness for a particular purpose. In no event shall SATA‐IO or any member of SATA‐IO be liable for any direct, indirect, special, exemplary, punitive,  or  consequential  damages,  including, without  limitation,  lost  profits,  even  if  advised  of  the possibility of  such damages. This material  is provided  for  reference only. The Serial ATA  International Organization does not endorse the vendor’s equipment outlined in this document 

Page 2: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  2  Digital MOI for JDSU Xgig Test Platform  

Microsoft, Microsoft Windows  2000, Windows  XP,  and Windows  Vista  are  registered  trademarks  or trademarks of Microsoft Corporation.   All other trademarks and registered trademarks are property of their respective owners.  THIS  DOCUMENT  IS  PROVIDED  TO  YOU  “AS  IS”  WITH  NO  WARRANTIES  WHATSOEVER, INCLUDING  ANY WARRANTY  OF MERCHANTABILITY,  NON‐INFRINGEMENT,  OR  FITNESS  FOR ANY  PARTICULAR  PURPOSE.  THE  AUTHORS  OF  THIS  DOCUMENT  DISCLAIM  ALL  LIABILITY, INCLUDING LIABILITY FOR INFRINGEMENT OF ANY PROPRIETARY RIGHTS, RELATING TO USE OR IMPLEMENTATION OF  INFORMATION  IN THIS DOCUMENT.   THE AUTHORS DO NOT WARRANT OR REPRESENT THAT  SUCH USE WILL NOT  INFRINGE  SUCH RIGHTS. THE PROVISION OF THIS DOCUMENT TO YOU DOES NOT PROVIDE YOU WITH ANY LICENSE, EXPRESS OR IMPLIED TO ANY INTELLECTUAL PROPERTY RIGHTS.  Copyright © 2009 by JDSU Corporation All rights reserved  Contacting JDSU JDSU Corporation 430 North McCarthy Blvd Milpitas, CA  95035  Main: 408‐546‐5000 Fax: 408‐546‐4300  Technical Support 1‐408‐546‐7096 ( International )  1‐866‐594‐2557 ( US Toll Free ) Website: www.jdsu.com  Questions/comments about this document send to: [email protected]      

 

Page 3: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  3  Digital MOI for JDSU Xgig Test Platform  

TABLE OF CONTENTS 

1. INTRODUCTION .......................................................................................... 6 PURPOSE ........................................................................................................................................ 6 REFERENCES .................................................................................................................................... 6 RESOURCE REQUIREMENTS ................................................................................................................ 6 LAST MODIFICATION ......................................................................................................................... 7 TEST SETUP ..................................................................................................................................... 7 TEST PROCEDURE ............................................................................................................................. 7 POST PROCESSING ............................................................................................................................ 7 OBSERVABLE RESULTS ....................................................................................................................... 7 POSSIBLE PROBLEMS ......................................................................................................................... 9

2. REFERENCES .............................................................................................. 10

3. TEST PROCEDURE ...................................................................................... 11 ASR‐01:COMINIT RESPONSE INTERVAL ........................................................................................... 11 ASR‐02:COMINIT OOB INTERVAL .................................................................................................. 12 GTR‐01:SOFTWARE RESET .............................................................................................................. 13 GTR‐02:3GB/S OR ABOVE SIGNALING SPEED BACKWARDS COMPATIBILITY ............................................... 15 GTR‐03: DMA PROTOCOL SUPPORT ................................................................................................ 17 GTR‐04:GENERAL SATA SUPPORT ................................................................................................... 20 GTR‐05:UNRECONGNIZED FIS RECEIPT (INFORMATIVE) ........................................................................ 21 NCQ‐01:FORCED UNIT ACCESS ........................................................................................................ 23 NCQ‐02:READ LOG EXT LOG PAGE 10H SUPPORT ................................................................................ 24 NCQ‐03:INTERMIX OF LEGACY AND NCQ COMMANDS ........................................................................ 26 NCQ‐04:DEVICE RESPONSE TO MALFORMED NCQ COMMANDS ............................................................ 28 NCQ‐05:DMA SETUP AUTO‐ACTIVATE ............................................................................................. 31 SSP‐01: INITIALIZE DEVICE PARAMETERS ............................................................................................ 33 SSP‐02: READ/WRITE STREAM ERROR LOG ........................................................................................ 35 SSP‐03: SECURITY MODE STATE ....................................................................................................... 37 SSP‐04: SET ADDRESS MAX ............................................................................................................ 39 SSP‐05: SET FEATURES – WRITE CACHE ENABLE/DISABLE ..................................................................... 41 SSP‐06: SET FEATURES – SET TRANSFER MODE .................................................................................. 43 SSP‐07: SET FEATURES – ADVANCED POWER MANAGEMENT ENABLE/DISABLE ......................................... 46 SSP‐08: SET FEATURES – READ LOOK‐AHEAD ..................................................................................... 48 SSP‐09: SET FEATURES – RELEASE INTERRUPT ..................................................................................... 49 SSP‐10: SET FEATURES – SERVICE INTERRUPT ..................................................................................... 51 SSP‐11: SET MULTIPLE MODE ......................................................................................................... 53 SSP‐12: SET FEATURES – WRITE‐READ‐VERIFY ................................................................................... 55 IPM‐01: PARTIAL STATE EXIT LATENCY (HOST‐INITIATED) ...................................................................... 57 IPM‐02: SLUMBER STATE EXIT LATENCY (HOST‐INITIATED) .................................................................... 59

Page 4: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  4  Digital MOI for JDSU Xgig Test Platform  

IPM‐03: SPEED MATCHING UPON RESUME (HOST‐INITIATED) ............................................................... 61 IPM‐04: NAK OF REQUESTS WHEN SUPPORT NOT INDICATED .............................................................. 63 IPM‐05: RESPONSE TO PMREQ_P .................................................................................................. 64 IPM‐06: RESPONSE TO PMREQ_S .................................................................................................. 66 IPM‐07: DEVICE DEFAULT SETTING FOR DEVICE INITIATED REQUESTS ...................................................... 67 IPM‐08: DEVICE INITIATED POWER MANAGEMENT ENABLE/DISABLE ...................................................... 69 IPM‐09: PARTIAL STATE EXIT LATENCY (DEVICE‐INITIATED)  ................................................................... 72 IPM‐10: SLUMBER STATE EXIT LATENCY (DEVICE‐INITIATED)  ................................................................. 74 IPM‐11: SPEED MATCHING UPON RESUME (DEVICE‐INITIATED)  ............................................................ 76 DOF‐01: ASYNCHRONOUS NOTIFICATION .......................................................................................... 78 DOF‐02: PHY SPEED INDICATOR ....................................................................................................... 81

APPENDIX A: TEST SETUP PROCEDURE .............................................................. 83

APPENDIX B – SETTING UP THE LABJACK DEVICE ............................................... 86

Page 5: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  5  Digital MOI for JDSU Xgig Test Platform  

MODIFICATION RECORD  Revision  Date  Comments 0.1  March 10, 2009 Initial draft 0.7  March 18, 2009 Internal  review,  updated  typos  and 

fixed certain test procedures 0.8  May 25, 2009 Updated to  include comments  from 

SATA‐IO  feedback,  plus  internal review and updated  to  the UTD 1.4 document. 

0.9  June 4, 2009 Reviewed  during  SATA‐IO conference call on June 4, 2009 and approved to .90 draft. 

0.91  August 5, 2009 Updated to support UTD 1.4 version .933,  updated  the MOI  for  IPM‐04. Replaced  Finisar  with  JDSU  and added “Informative” to some tests. 

1.0RC  August 13, 2009 Updated  to  1.0RC  by  SATAIO  vote approval on 08/13/09.   Accepted all changes and also due  to  formatting errors,  found and  fixed some minor typos in document. 

1.0  October 15, 2009 Updated  to  1.0  Release  Status  by vote during  the  SATAIO  conference call  on  October  15,  2009.  Also, updated  contact  information  for JDSU. 

 ACKNOWLEDGMENTS    The author would like to acknowledge the efforts of the following individuals in the development and review of this document:    

• Amit Bakshi, Lecroy • John Calvin, Tektronix • Yeow Chuan Chng, JDSU • Tien Hiong Lee, JDSU • Tim Mostad, VTM • Yun Wang, Ulink 

 

Page 6: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  6  Digital MOI for JDSU Xgig Test Platform  

 1. INTRODUCTION The  test  definitions  themselves  are  intended  to  provide  a  high‐level  description  of  the motivation, resources, procedures, and methodologies specific to each test.  Formally, each test description contains the following sections:  Purpose The purpose is a brief statement outlining what the test attempts to achieve.  The test is written at the functional level.   References This section specifies all reference material external to the test suite, including the specific sub clauses  references  for  the  test  in question, and any other  references  that might be helpful  in understanding the test methodology and/or test results.  External sources are always referenced by a bracketed number (e.g., [1]) when mentioned in the test description.  Any other references in  the  test description  that are not  indicated  in  this manner refer  to elements within  the  test suite document itself (e.g., “Appendix 5.A”, or “Table 5.1.1‐1”)  Resource Requirements The requirements section specifies the test hardware and/or software needed to perform the test.   This  is generally expressed  in  terms of minimum  requirements, however  in  some  cases specific equipment manufacturer/model information may be provided. In order to perform the tests, the following hardware and software components are needed as shown in Table 1‐1.  

Table 1‐1: Required Testing Resources 

Item  Description 1  Windows  2000,  XP  or  Vista  Host  Computer,  with  the  following minimum  characteristics:  

512MB RAM, Ethernet Port, Keyboard, Mouse, Monitor,  and  active network  connection  to LAN. 

2  Functional LAN to support HOST computer and Xgig Testing Platform 3  JDSU Xgig 6 Gb/s SAS/SATA Testing Platform which contains  6Gb wide port blade and Chassis 4  Mini SAS x4 External Connector to 4 SATA x1 Internal Connectors Cable (SFF‐8088) 5  Vendor Supplied SATA Target Device , Device Under Test (DUT) 6  Vendor Supplied Power Supply to power the DUT 7  Correct media compatible with ATAPI devices; Blank RW media or known media disc 8  Power controller devices for automated testing of DUT (For example, LabJack Device)   

Page 7: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  7  Digital MOI for JDSU Xgig Test Platform  

Last Modification This specifies the date of the last modification to this test, which can be found in the Modification Record section.  Test Setup The setup section describes the initial configuration of the test environment.  Small changes in the configuration should not be included here, and are generally covered in the test procedure section.  Test Procedure The procedure section of the test description contains the systematic  instructions  for carrying out  the  test.    It  provides  a  cookbook  approach  to  testing,  and  may  be  interspersed  with observable results.  Post Processing This section  lists the steps  involved to analyze the Xgig trace result for  integrity verification of each tests. In this test suite, all of the tests perform automatic verification on the test results, except for tests NCQ-03 and ASR-02. For all tests with automatic verification, Post Processing is optional. User may conduct Post Processing to validate the behaviour of the DUT as well as to understand how the DUT had responded to each tests.  To view the decoded Identify (Packet) Device data, user must run Xgig Expert on the trace result and have Expert ports added to the original trace. Next, the trace result on Xgig TraceView must be reloaded.  Observable Results This section  lists the specific observables that can be examined by the tester  in order to verify that the DUT  is operating properly.   When multiple values for an observable are possible, this section provides a short discussion on how to  interpret them.   The determination of a pass or fail outcome for a particular test is generally based on the successful (or unsuccessful) detection of a specific observable. See Figure 1‐1 below shows the JDSU Compliance Suite result view  

Page 8: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  8  Digital MOI for JDSU Xgig Test Platform  

 

Figure 1‐1: Compliance Test Result View 

Also,  the  results  can  be  viewed  by  inspecting  the  tool’s  log  file,  which  can  be  found  at: c:\Program Files\Finisar\Xgig SATA CTS\log, assuming that JDSU Compliance Suite software  is  being  installed  in  c:\Program Files\Finisar, and  double  click  the appropriate file for review and analysis.   The test results falls into the following categories:  

1. The  result of “Passed”  indicates  the DUT has  fulfilled  the  required  testing criteria via the JDSU Compliance Test Procedure.  

2. The result of “Failed”  indicates the DUT has NOT fulfilled the required testing criteria via the JDSU Compliance Test Procedure in one or more areas.  

3. The  results  of  “N/A”  indicates  the  test  does  not  apply  to  a  particular  DUT, which  is obtained from examining the DUT’s identify page.  

4. The results of “Test Aborted” or “Error” indicates a critical error has occurred which prohibited the test from executing against the target DUT. 

 

Page 9: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  9  Digital MOI for JDSU Xgig Test Platform  

5. The results of “Invalid Device” indicates that an invalid DUT type (ATA or ATAPI) has been detected, and test will not be performed on the DUT. 

 6. The results of “Manual Stopped” indicates that the test has been manually stopped by 

the user during its execution.  

7. The  results  of  “Manual Verification”  indicates  that  the  test  requires  user  to perform manual verification to determine its compliance, based on the Xgig trace result. 

 8. The  results of  “Timed Out”  indicates  that  the  time  taken by  the  test  to execute has 

passed the timeout value defined by user, and the test is terminated.  Possible Problems This section contains a description of known  issues with the test procedure, which may affect test results  in certain situations.    It may also refer the reader to test suite appendices and/or other external sources that may provide more detail regarding these issues.  

1. If the host computer loses LAN connectivity from the Xgig Testing Platform, the tests will be aborted. The following error may be displayed as a result:  Cannot Acquire Tester Card from Driver, OpenTester failed Can't Open Tester...aborting test Error Code is 1 Should the above error occur, validate the LAN environment and associated cables for the HOST Computer and Xgig Testing Platform.  

2. Is it recommended that the Xgig testing platform port speed be set to match the same speed of the DUT rather than using the auto detect feature in those cases where the port speed auto detection is not working. 

  

Page 10: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  10  Digital MOI for JDSU Xgig Test Platform  

 

2. REFERENCES The following document is referenced in this document:  • Serial ATA Revision 2.5 • Serial ATA Revision 3.0 • SATA‐IO Interoperability Rev 1.4 Unified Test Document 

Page 11: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  11  Digital MOI for JDSU Xgig Test Platform  

 3. TEST PROCEDURE  ASR‐01:COMINIT Response Interval  Purpose:  To  verify  that  a  device  in  quiescent  state will  respond  to  a  host  COMRESET signal with  an associated COMINIT signal within 10 milliseconds.  Status: Informative Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  After connecting the DUT and powering it on, the Host Emulator tool will issue a COMRESET to the device. The automated Test Procedure measures the response time. Also, while performing this test, capture a trace and validate response time results. This test  is executed a total of 5 times.  Test Setup:  See section Appendix A: Test Setup Procedure on page 83.  Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the ASR-01 Test in the tool to activate this test. 

 3. Click the Start Tests Button (This test is automatically executed 5 times). 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The ASR-01 Test does the following: 

1. Power cycle the device.   

2. Initiate COMRESET sequence.  

Page 12: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  12  Digital MOI for JDSU Xgig Test Platform  

3. Verify  OOB  sequence  completion  and  COMINIT  is  within  10  milliseconds  after COMRESET  is  transmitted  by  host.  If  this  criteria  is  not  fulfilled,  test  is  marked  as “FAILED”. 

 Post Processing: (See section Post Processing on page 7.) 

1. Review host side COMRESET and Device  response COMINIT  in  the captured  trace and verify correct execution of the test.  

2. Verify  that  the  COMINIT  response  timing  to  the  COMRESET  request  is  within  the window of 10 milliseconds in the trace. 

 Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   ASR‐02:COMINIT OOB Interval  Purpose:  When host  is powered off or under PHY OFFLINE,  test will  confirm  that  the device does not initiate a new out of band (OOB) COMINIT to the host faster than 10 milliseconds.  Status: Informative  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  The host emulator is disabled and not transmitting to the device, and then only device activities are  captured  and  analyzed.  The  time  distance  between  each  two  consecutive  COMINIT exchanges,  send by  the device  is measure within  the  captured  trace.  The out of window  or invalid time period is reported in the tool. This test is executed a total of 10 times.  

Page 13: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  13  Digital MOI for JDSU Xgig Test Platform  

Test Setup:  See section Appendix A: Test Setup Procedure on page 83. Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the ASR-02 Test in the tool to activate this test.  3. Click the Start Tests Button (This test is automatically executed 10 times). 

 The ASR-02 Test does the following: 

1. Power cycle the device.   2. Prompt user to start Xgig tracing. 

 3. Power off the host or place the host under PHY OFFLINE mode. 

 4. Introduce a delay of 1.5 seconds before issuing a COMRESET, to return the host to initial 

mode.  

5. Prompt user to stop Xgig tracing and manually perform the following verifications: • Verify that once host is powered off or went into PHY OFFLINE mode, device sends 

COMINIT repeatably. • The time interval between each COMINIT sent by the device must not be faster than 

10 milliseconds. If these criteria are not fulfilled, user is to mark the test as “FAILED”. 

 Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.  JDSU GTR‐01:Software Reset  Purpose:  

Page 14: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  14  Digital MOI for JDSU Xgig Test Platform  

To determine if a Device can successfully process a Device‐To‐Host FIS request and process the software reset protocol correctly. Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  After a host  issues a COMRESET to the Device and the Device then successfully acknowledged without  any  errors,  a  Device  then  shall  successfully  respond  to  the  setting  of  the  SRST (Software Reset) bit in the Device Control register and perform the software reset protocol. The device must respond within 31 seconds. This test is executed a total of 5 times.  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure:  Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. For ATAPI device, place JDSU Special CD in Drive Tray. 

 3. Click the GTR-01 Test in the tool to activate this test. 

 4. Click the Start Tests Button (This test is automatically executed 5 times). 

 5. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The GTR-01 Test does the following: 

1. Issue either IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) to the Device. 

 2. Issue either READ SECTOR (ATA) or READ CD (ATAPI) to the Device. 

 3. Issue a SRST to the Device. 

 4. Verify  that  after  the  software  reset  sequence,  the  received  Register  FIS  contains  no 

errors and has the appropriate signature content  in the Sector Count and LBA fields.  If this criteria is not fulfilled, test is marked as “FAILED”. 

Page 15: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  15  Digital MOI for JDSU Xgig Test Platform  

  Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace,  verify  that  Software Reset  (SRST) was  issued  correctly by  the host. Ensure that BSY, DRQ, or ERR bits are not set.  

 2. Verify that reset falls with the 31 second window and Register FIS received corresponds 

to the following: • Status Register Bit: 7, 3, and 0 shall be set to: 0h • Error register shall be set to: 01h • Sector Count shall be set to: 01h • LBA Low shall be set to: 01h • LBA Mid shall be set to: 00h (ATA) or 14h (ATAPI) • LBA High shall be set to: 00h (ATA) or EBh (ATAPI) 

 Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.   

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   GTR‐02:3Gb/s or Above Signaling Speed Backwards Compatibility  Purpose:  To validate  if a Device claims support for Serial ATA Gen‐2 (and Gen‐3 signaling speed),  it also supports Serial ATA Gen‐1 signaling speed.    Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  

Page 16: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  16  Digital MOI for JDSU Xgig Test Platform  

An IDENTIFY (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command is issued to the Device to validate support for Gen‐3, Gen‐2 speeds and Gen‐1 speeds. This test  is executed a total of 10 times.  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the GTR-02 Test in the tool to activate this test.  3. Click the Start Tests Button (This test is automatically executed 10 times). 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The GTR-02 Test does the following: 

1. Issue either IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) to the Device. 

 2. Check Interface Speed Support (WORD 76, bits 3:1). 

 3. For any interface speed grade that is supported, verify that all other speed grades below 

this grade is supported also. If this criterion is not fulfilled, test is marked as “FAILED”.  

4. Set interface speed to highest supported speed grade.   

5. Issue COMRESET and complete OOB sequence.  

6. Verify that after the OOB sequence, the received Register FIS contains no errors and has appropriate signature content  in the Sector Count and LBA fields.  If this criterion  is not fulfilled, test is marked as “FAILED”. 

 7. This test is repeated with all other supported speed grades below the highest supported 

speed grade.  Post Processing: (See section Post Processing on page 7.) 

1. Within a trace, verify that host successfully set the link to all supported interface speed grades and issue a COMRESET.  

Page 17: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  17  Digital MOI for JDSU Xgig Test Platform  

 2. A  device must  support  all  other  speed  grades  below  its  highest  supported  interface 

speed  grade.  For  example,  if  the  device  supports  6.0G  interface  speed,  it must  also support 3.0G and 1.5G interface speed grades as well. 

3. After  COMRESET  is  issued,  within  the  trace,  verify  that  the  Register  FIS  received corresponds to the following: • Status Register Bit: 7, 3, and 0 shall be set to: 0h • Error register shall be set to: 01h • Sector Count shall be set to: 01h • LBA Low shall be set to: 01h • LBA Mid shall be set to: 00h (ATA) or 14h (ATAPI) • LBA High shall be set to: 00h (ATA) or EBh (ATAPI) 

 Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   GTR‐03: DMA Protocol Support  Purpose:  To validate  if a Device supports DMA  Identify Page  information, DMA modes, and handles all DMA requests and issues the correct responses to each DMA operation.  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009  Discussion:  First check WORD 49 Bit 8 which should be 1 to determine DMA support. Next, determine the highest  level  of  Ultra  DMA  mode  supported  by  Device  and  then  set  to  that  mode.  Issue IDENTIFY (PACKET) DEVICE to validate that DMA mode has been set correctly. Followingly, issue a  series of WRITE/READ  command  (for ATA), WRITE/READ CD  (for RW ATAPI) or  just 

Page 18: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  18  Digital MOI for JDSU Xgig Test Platform  

READ CD (For RO ATAPI) to determine correct operations. Check for data mismatch.  This test is executed a total of 5 times.  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the GTR-03 Test in the tool to activate this test.  3. Click the Start Tests Button (This test is automatically executed 5 times). 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The GTR-03 Test does the following: 

1. Issue an IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command and check to see if WORD 49, bit 8 is set, if not, mark test as “N/A”.  

2. Check that the content in WORD 88 is valid (WORD 53, bit 2).  

3. Check on the Ultra DMA modes that are supported (WORD 88, bits 6:0). If Ultra DMA is supported,  issue SET FEATURES to set the device to use the highest supported Ultra DMA mode. 

 4. If Ultra DMA is not supported, check on the Multi‐Word DMA modes that are supported 

(WORD 63, bits 2:0). If Multi‐Word DMA is supported, issue SET FEATURES to set the device  to  use  the  highest  supported Multi‐Word DMA mode.  If  both Ultra DMA  and Multi‐Word DMA are not supported, test is marked as “FAILED”. 

 5. For ATA devices, issue a WRITE DMA command with transfer size of 8Kbytes.  

 6. Issue a READ DMA command to the same disk location. 

 7. Verify that the data read matches the data written. If this criterion is not fulfilled, test is 

marked as “FAILED”.  

8. Repeat steps 5‐7 with transfer size of 128Kbytes.  

Page 19: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  19  Digital MOI for JDSU Xgig Test Platform  

9. For ATAPI  devices  that  support writing  to media,  complete  one  track worth  of write commands with transfer size of 8Kbytes. 

 10. Complete one track worth of read commands to the same disk location. 

 11. Verify that the data read matches the data written. If this criterion is not fulfilled, test is 

marked as “FAILED”.  

12. Repeat steps 9‐11 with transfer size of 128Kbytes.  

13. For ATAPI devices that only support reading from media (e.g. CDROM, DVDROM, etc.), complete one track worth of read commands with transfer size of 8Kbytes. 

 14. Complete another track worth of read commands to the same disk location. 

 15. Verify that data read from both sets of read commands matches. If this criterion is not 

fulfilled, test is marked as “FAILED”.  

16. Repeat steps 13‐15 with transfer size of 128Kbytes.  Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace, verify  that  the SET FEATURES command was executed successfully and  its  changes  to  the  DMA  mode  were  reflected  in  the  IDENTIFY (PACKET) DEVICE (ATA) data.  

2. For ATA Devices: • Ensure that the WRITE DMA and READ DMA commands were executed successfully.  

• If  all  WRITE/READ DMA  commands  completed  successfully,  then  ensure  that  the data read matches the data written.  

 3. For ATAPI Devices (Support Writing To Media): 

• Ensure that the WRITE 10 and READ 10 commands were executed successfully.  • If all WRITE/READ 10 commands completed successfully, then ensure that the data read matches the data written. 

 4. For ATAPI Devices (Support Reading From Media): 

• Ensure that the READ 10 commands were executed successfully.  

Page 20: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  20  Digital MOI for JDSU Xgig Test Platform  

• If all READ 10 commands completed  successfully,  then ensure  that  the data  read from similar disk locations returns a match. 

 Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.   

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   GTR‐04:General SATA Support  Purpose:  To determine if a Device Identify Page data (WORD 93) content is cleared to zero and that the Device supports 1.5G signaling speed (WORD 76, bit 1).  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  After  a host  issues  an IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE  (ATAPI), verify that WORD 93 is all 0s and that WORD 76 (Bit 1) is set to 1.  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the GTR-04 Test in the tool to activate this test.  3. Click the Start Tests Button. 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional). 

Page 21: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  21  Digital MOI for JDSU Xgig Test Platform  

 The GTR-04 Test does the following: 

1. Issue  an  IDENTIFY DEVICE (ATA)  or  IDENTIFY PACKET DEVICE (ATAPI) command.  

2. Verify  that WORD 93  is  cleared  to 0.  If  this  criterion  is not  fulfilled,  test  is marked as “FAILED”. 

 3. Verify that Serial ATA Gen‐1 interface speed (WORD 76, bit 1) is supported (set to 1). If 

this criterion is not fulfilled, test is marked as “FAILED”.  

4. Verify that bit 0 of WORD 79:76 are cleared to 0. If this criterion is not fulfilled, test is marked as “FAILED”.  

Post Processing: (See section Post Processing on page 7.) 1. Within the trace, verify that within the IDENTIFY (PACKET) DEVICE data, WORD 76 

bit 1 is set to 1, bit 0 of WORD 79:76 should be cleared to 0.  Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   GTR‐05:Unrecongnized FIS Receipt (Informative)  Purpose:  To determine if a Device will reject unrecognized FIS requests, thus proving that link layer state machine  definitions  found  in  the  Serial  ATA  specifications  are  operating  correctly. When  a device rejects a FIS, it will respond with an R_ERR response.  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   

Page 22: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  22  Digital MOI for JDSU Xgig Test Platform  

Discussion:  From a SATA specification point of view, a Device response to a recognized FIS is with a R_OK. This test will validate that when the Host sends a total of 242 unrecognized FIS requests, the Device  must  response  to  them  all  with  an  R_ERR.  This  test  is  considered  “Informative”. However, test result information is displayed in the testing tool. Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the GTR-05 Test in the tool to activate this test.  3. Click the Start Tests Button. 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The GTR-05 Test does the following: 

1. Issue  an  IDENTIFY DEVICE (ATA)  or  IDENTIFY PACKET DEVICE (ATAPI) command. 

 2. Issue undefined FIS to the device.  3. Verify that R_ERR primitives are received from the device. If this criterion is not fulfilled, 

test is marked as “FAILED”.  4. This test is repeated with a total of 242 undefined FIS issued to the device. 

 Post Processing: (See section Post Processing on page 7.) 

1. Within the trace, verify that transmit of undefined FIS to the device were successful.   2. Verify  that  all  the  responses  from  the  device  to  each  undefined  FIS  were  R_ERR

primitives.  Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

Page 23: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  23  Digital MOI for JDSU Xgig Test Platform  

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.  NCQ‐01:Forced Unit Access  Purpose:  To  determine  if  a  Device  supports  READ FPDMA QUEUED  and  WRITE FPDMA QUEUED commands. If so, then it shall also support the Force Unit Access (FUA) bit as well. Note: This test is not applicable to ATAPI devices.  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  Check  to  see  if  the  data written  is  the  same  as  the  read;  using  the  READ/WRITE FPDMA QUEUED commands.  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the NCQ-01 Test in the tool to activate this test.  3. Click the Start Tests Button. 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The NCQ-01 Test does the following: 

1. Issue an IDENTIFY DEVICE command and check to see if NCQ is supported (WORD 76, bit 8 is set), ). If not, mark test as “N/A”.   

2. Issue a WRITE FPDMA QUEUED command with FUA bit set to 1. 

Page 24: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  24  Digital MOI for JDSU Xgig Test Platform  

 3. Issue a READ FPDMA QUEUED command to the same disk location. 

 4. Verify  that data  read matches  the data written.  If  this  criterion  is not  fulfilled,  test  is 

marked as “FAILED”.  

Post Processing: (See section Post Processing on page 7.) 1. Within  the  trace, verify that NCQ  is supported as reflected  in  the IDENTIFY DEVICE 

data (WORD 76, bit 8 set to 1).  

2. Check  that  all WRITE FPDMA QUEUED and READ FPDMA QUEUED commands  are completed successfully.   

 3. Ensure that the data read matches the data written. 

 Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   NCQ‐02:Read Log Ext log page 10h Support  Purpose:  To determine  if a Device  that claims  support  for NCQ  (WORD 76, Bit 0)  is  set  to 1,  then  the Device  shall  also  support READ LOG EXT  to log page 10h  and General Purpose  Logging feature set. Note: This test is not applicable to ATAPI devices.  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  

Page 25: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  25  Digital MOI for JDSU Xgig Test Platform  

When NCQ  support  is  claimed,  see  if  the READ LOG EXT  log page  is  available and General Purpose Logging Feature is supported.  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

  

Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the NCQ-02 Test in the tool to activate this test.  3. Click the Start Tests Button. 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The NCQ-02 Test does the following: 

1. Issue an IDENTIFY DEVICE command and check to see if NCQ is supported (WORD 76 bit 8 is set), ). If not, mark test as “N/A”.   

2. Check that General Purpose Logging Feature is supported (WORD 87, bit 5 is set to 1).  

3. Issue READ LOG EXT to log page 00h.  

4. Verify the successful completion and data transfer for log page 00h. If this criterion is not fulfilled, test is marked as “FAILED”. 

 5. Verify  that within  log page 00h,  offset  20h  contains  a  value  of  1  and  offset  21h 

contains a value of 0. If this criterion is not fulfilled, test is marked as “FAILED”.  

6. Issue READ LOG EXT to log page 10h.  

7. Verify the successful completion and data transfer for log page 10h. If this criterion is not fulfilled, test is marked as “FAILED”. 

 Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace, verify that NCQ  is supported as reflected  in  the IDENTIFY DEVICE data (WORD 76, bit 8 set to 1). 

 

Page 26: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  26  Digital MOI for JDSU Xgig Test Platform  

2. WORD 87, bit 5 should also be set to 1 to reflect the device’s support  for the General Purpose Logging Feature.   

3. Check that both READ LOG EXT (00h) and READ LOG EXT (10h) commands are completed successfully and that the log page data is transferred correctly. 

 4. Within the  log page data  for log page 00h, offset 20h should contain a value of 1, 

and offset 21h should contain a value of 0.  Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.  

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   NCQ‐03:Intermix of Legacy and NCQ Commands  Purpose:  To determine  if a Device receiving a  legacy ATA command while a NCQ command  is pending, when an error has occurred and the Device shall handle the necessary state cleanup and return to the state with no commands pending. Note: This test is not applicable to ATAPI devices.  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  July 29, 2009   Discussion:  The device shall set an error condition to the host by issuing a Register FIS with the ERR bit set to 1 and the BSY bit cleared to 0, then the error field (ABRT bit) will be set to 1. If there were NCQ command pending, the device shall stop processing commands until the READ LOG EXT command  is  issued. When  this  command  is  received  by  the  Device,  the  FIS  to  discard  any pending commands in the device queue.  Test Setup:  

Page 27: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  27  Digital MOI for JDSU Xgig Test Platform  

See section Appendix A: Test Setup Procedure on page 83.  

Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the NCQ-03 Test in the tool to activate this test.  3. Click the Start Tests Button. 

 The NCQ-03 Test does the following: 

1. Issue an IDENTIFY DEVICE command and check to see if NCQ is supported (WORD 76, bit 8 is set), if not, mark test as “N/A”.   

2. Check Maximum Queue Depth – 1 (WORD 75, bits 4:0).  

3. Prompt user to start Xgig tracing.  

4. Issue X number of READ FPDMA QUEUED commands, where X  is the Maximum Queue Depth – 1. 

 5. Issue legacy ATA command: IDENTIFY DEVICE. 

 6. Upon receiving a Register FIS with error, a READ LOG EXT command will be  issued to 

log page 10h.  

7. Verify that in the data within log page 10h, NQ bit is 1. If this criterion is not fulfilled, test is marked as “FAILED”.  

 8. Verify that  in the data within  log page 10h, checksum  is correct.  If this criterion  is not 

fulfilled, test is marked as “FAILED”.  

9. Prompt user to stop Xgig tracing and manually perform the following verifications: i. Verify  the  receipt of Register FIS with  the  following criteria after  the  legacy ATA 

command is issued: • BSY bit = 0 • ERR bit = 1 • ABRT bit = 1 

ii. Verify the receipt of Set Device Bits FIS with the following criteria after READ LOG EXT is issued: • BSY bit = 0 

Page 28: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  28  Digital MOI for JDSU Xgig Test Platform  

• DRDY bit = 1 • DF bit = 0 • DRQ bit = 0 • ERR bit = 0 • ‘I’ bit = 0  • SActive field = FFFFFFFFh 

If these criteria are not fulfilled, user is to mark the test as “FAILED”.  

10. The test is repeated with the following legacy ATA commands: i. WRITE SECTOR ii. READ DMA iii. READ LOG EXT with log page 10h 

 Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   NCQ‐04:Device Response to Malformed NCQ Commands  Purpose:  To determine if a Device handles malformed NCQ command correctly. For example, a duplicate tag value can be received for an outstanding NCQ command, or the specified LBA is out of the devices supported range. Note: This test is not applicable to ATAPI devices.  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  July 29, 2009   Discussion:  TBD  

Page 29: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  29  Digital MOI for JDSU Xgig Test Platform  

Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional). 2. Click the NCQ-04 Test in the tool to activate this test.  3. Click the Start Tests Button. 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The NCQ-04 Test does the following: 

1. Issue an IDENTIFY DEVICE command and check to see if NCQ is supported (WORD 76 bit 8 is set), ). If not, mark test as “N/A”. 

 2. Check Total Number of User Addressable Sectors (WORD 61:60 and WORD 103:100). 

 3. Issue READ FPDMA QUEUED with LBA out of range. 

 4. Verify  that either a Register FIS or a Set Device Bits FIS  is  received with  the  following 

criteria: • ERR bit = 1 • DRDY bit = 0 • ‘I’ bit = 1 • Either the ABRT bit or IDNF bit = 1 

If these criteria are not fulfilled, test is marked as “FAILED”.  

5. Issue READ LOG EXT to log page 10h.  6. Verify that the Set Device Bits FIS is received with the following criteria: 

• ERR bit = 0 • DRDY bit = 1 • DF bit = 0 • ‘I’ bit = 0 • SActive Field = FFFFFFFFh 

If these criteria are not fulfilled, test is marked as “FAILED”.  

7. In the data within log page 10h, verify that the following criteria are matched: • TAG field includes the tag associated with the malformed NCQ command 

Page 30: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  30  Digital MOI for JDSU Xgig Test Platform  

• NQ bit = 0 • ERR bit = 1 • DRDY bit = 1 • DF bit = 0 • For test involving malformed NCQ command with out‐of‐range LBA, either ABRT 

bit or IDNF bit = 1 • For all other tests involving malformed NCQ commands, ABRT bit = 1 • Checksum is correct 

If these criteria are not fulfilled, test is marked as “FAILED”.  

8. For test  involving malformed NCQ command with out‐of‐range LBA,  in the data within  log page 10h, LBA field must include the LBA address issued in the failed NCQ command. If this criterion is not met, test is marked as “FAILED”. 

 9. Test is repeated with the following malformed NCQ commands: 

• Issue 2 READ FPDMA QUEUED with duplicated tag • Issue READ FPDMA QUEUD with tag value out of device supported range 

 Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace, verify that NCQ  is supported as reflected  in  the IDENTIFY DEVICE data (WORD 76, bit 8 set to 1). 

 2. Check that all malformed READ FPDMA QUEUED commands are executed successfully 

with errors being returned as either a Register FIS or a Set Device Bits FIS. The content within either one of these FISes should be: 

• ERR bit = 1 • DRDY bit = 0 • ‘I’ bit = 1 • Either the ABRT bit or IDNF bit = 1 

 3. Check that all READ LOG EXT commands are executed successfully with Set Device Bits 

FIS being returned. The content within the Set Device Bits FIS should be: • ERR bit = 0 • DRDY bit = 1 • DF bit = 0 • ‘I’ bit = 0 • SActive Field = FFFFFFFFh 

 4. Verify that the content in the data within log page 10h should have: 

• TAG field is associated to the tag of the malformed NCQ command 

Page 31: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  31  Digital MOI for JDSU Xgig Test Platform  

• NQ bit = 0  • ERR bit = 1 • DRDY bit = 1 • DF bit = 0 • If  the  test  involves malformed  NCQ  command  with  out‐of‐range  LBA,  either 

ABRT bit or IDNF bit = 1, and the LBA field should include the LBA address of the failed NCQ command 

• If the test involves other types of malformed NCQ commands, ABRT bit = 1 • Checksum is correct 

 Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   NCQ‐05:DMA Setup Auto‐Activate  Purpose:  To determine if a Device that claims support DMA Setup Auto‐Activate feature will not transmit a DMA Activate FIS to trigger transmission of the first Data FIS from the host,  if  it had already sent a DMA setup FIS with the Auto-Activate bit set to 1. Note: This test is not applicable to ATAPI devices.  Resource Requirements: See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  Check to see  if a device claims support for DMA Setup Auto Activiate, by examining WORD 78 bit 2 is set to 1. If true, a device shall not send a DMA Activate FIS if it had already sent a DMA Setup FIS with “A” bit set to 1.  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

Page 32: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  32  Digital MOI for JDSU Xgig Test Platform  

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional). 2. Click the NCQ-05 Test in the tool to activate this test.  3. Click the Start Tests Button. 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The NCQ-05 Test does the following: 

1. Issue an IDENTIFY DEVICE command and check to see if NCQ is supported (WORD 76 bit 8 is set), ). If not, mark test as “N/A”. 

 2. Check that DMA Setup Auto‐Activation is supported (WORD 78, bit 2 is set to 1). 

 3. Issue a SET FEATURES command with Sector Count = 02h and Features = 10h

to enable DMA Setup Auto‐Activation.  

4. Verify that DMA Setup Auto‐Activation (WORD 79, bit 2)  is successfully enabled.  If this criterion is not fulfilled, test is marked as “FAILED”. 

 5. Issue WRITE FPDMA QUEUED with Auto-Activate bit set to 1. 

 6. Verify that the initial DMA Activate FIS is missing prior to first transmitted Data FIS. If 

this criterion is not fulfilled, test is marked as “FAILED”.  

7. Verify that the WRITE FPDMA QUEUED command completed successfully. If this criterion is not fulfilled, test is marked as “FAILED”. 

 Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace, verify that NCQ  is supported as reflected  in  the IDENTIFY DEVICE data (WORD 76, bit 8 set to 1). 

 2. WORD 78, bit 2 should also be set to 1  to reflect  the device’s support  for DMA Setup 

Auto‐Activation.   3. Verify  that  the SET FEATURES  command was executed  successfully  and DMA  Setup 

Auto Activation was enabled, as reflected in the IDENTIFY (PACKET) DEVICE data.  

Page 33: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  33  Digital MOI for JDSU Xgig Test Platform  

4. Check that the WRITE FPDMA QUEUED command was executed successfully.  

5. From the trace, observe that between the DMA Setup FIS and the  first Data FIS, DMA Activate FIS is missing. 

Observable Results:  (See section Observable Results on page 7.) 1. Examine the test result section of the JDSU compliance test suite main window or view 

the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   SSP‐01: Initialize Device Parameters  Purpose:  To  validate  if  a  Device  when  receiving  a  COMRESET,  shall  maintain  the  device  settings established by the INITIALIZE DEVICE PARAMETERS command.   Note: This test is not applicable to ATAPI devices.  Resource Requirements:   See section Resource Requirements on page 6. Last Modification:  June 15, 2009   Discussion:  TBD  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the SSP-01 Test in the tool to activate this test.  3. Click the Start Tests Button. 

 

Page 34: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  34  Digital MOI for JDSU Xgig Test Platform  

4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to analyze the Xgig trace result of this test (Optional). 

   The SSP-01 Test does the following: 

1. Issue an IDENTIFY DEVICE command and check to see if SSP is supported (WORD 78, bit 6 set to 1) and WORD 58:54 are valid (WORD 53, bit 0 set to 1). If these bits are not set, mark test as “N/A”. 

 2. Check the value of Device Settings (WORD 58:54). 

 3. Issue an INITIALIZE DEVICE PARAMETERS command to change the values of Device 

Settings.  

4. Verify that the values of Device Settings are changed successfully. If this criterion is not fulfilled, test is marked as “FAILED”.  

5. Issue a COMRESET and complete the OOB sequence.  

6. Issue an IDENTIFY DEVICE command and verify that the content of Device Settings is maintained after a COMRESET.  If  this criteriacriterion  is not  fulfilled,  test  is marked as “FAILED”. 

 Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace, verify  that SSP  is  supported as  reflected  in  the IDENTIFY DEVICE data (WORD 78, bit 6 set to 1). 

 2. WORD 53, bit 0 should also be set to 1 to reflect that the content within WORD 58:54 is 

valid.  

3. Check  that  the  INITIALIZE DEVICE PARAMETERS  command  was  executed successfully and the content within WORD 58:54 was changed from its default values.  

 4. Verify that COMRESET was completed successfully and the content within WORD 58:54 

remained the same as before the COMRESET was issued.  Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

Page 35: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  35  Digital MOI for JDSU Xgig Test Platform  

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9. SSP‐02: Read/Write Stream Error Log  Purpose:  To validate that a Device, when claiming support  for Streaming, that  it maintains values  from Read Stream Error Log after a COMRESET. Note: This test is not applicable to ATAPI devices.  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  TBD  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the SSP-02 Test in the tool to activate this test.  3. Click the Start Tests Button. 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The SSP-02 Test does the following: 

1. Issue an IDENTIFY DEVICE command and check to see if SSP is supported (WORD 78, bit 6 set  to 1) and Streaming Feature Set Supported  (WORD 84, bit 4 set  to 1).  If these bits are not set, mark test as “N/A”. 

 2. Issue  a  READ LOG EXT  command  to  get  the  default  content  of  the  READ  STREAM 

ERROR LOG (log page 22h). 

Page 36: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  36  Digital MOI for JDSU Xgig Test Platform  

 3. Issue a WRITE LONG command to generate error at LBA location 30h. 

 4. If  the WRITE LONG command  is not  supported,  issue SCT WRITE LONG  to generate 

error at LBA location 30h. 5. If the SCT WRITE LONG command is not supported, issue WRITE UNCORRECTABLE to 

generate error at LBA location 30h.  

6. Verify that the content in the READ STREAM ERROR LOG is successfully changed. If this criterion is not fulfilled, test is marked as “FAILED”.  

7. Issue a COMRESET and complete OOB sequence.  

8. Issue a READ LOG EXT command to get the content of the READ STREAM ERROR LOG.  

9. Verify  that  the  content  of  the  READ  STREAM  ERROR  LOG  is  maintained  after  a COMRESET. If this criteria is not fulfilled, test is marked as “FAILED”. 

 Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace, verify  that SSP  is  supported as  reflected  in  the IDENTIFY DEVICE data (WORD 78, bit 6 set to 1). 

 2. WORD 84, bit 4  should also be  set  to 1  to  reflect  the device’s  support  for  Streaming 

Feature Set.  

3. Either  a  WRITE LONG  command,  or  an  SCT WRITE LONG  command,  or  a  WRITE UNCORRECTABLE command will be issued to generate stream error. Check that any one of these commands was executed successfully. 

 4. Check that the content within the Read Stream Error Log (log page 22h) was changed 

from  its  default  values,  and  these  newly  changed  values  remained  the  same  after COMRESET was issued. 

 Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  

Page 37: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  37  Digital MOI for JDSU Xgig Test Platform  

See section Possible Problems on page 9.    SSP‐03: Security Mode State  Purpose:  To  validate  that  a Device, when  claiming  support  for  Security Mode,  after  a COMRESET, will maintain the value of the Security Mode setting.  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  TBD  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the SSP-03 Test in the tool to activate this test.  3. Click the Start Tests Button. 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The SSP-03 Test does the following: 

1. Issue  an IDENTIFY DEVICE or IDENTIFY PACKET DEVICE  (ATAPI)  command  and check to see  if SSP  is supported (WORD 78, bit 6 set to 1) and Security Feature Set  is supported (WORD 82, bit 1 set to 1). If these bits are not set, mark test as “N/A”.  

2. Verify that Security Feature Set is enabled (WORD 85, bit 1 is set to 1).  

3. If SECURITY STATUS is LOCKED, issue a SECURITY UNLOCK command.  

Page 38: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  38  Digital MOI for JDSU Xgig Test Platform  

4. Issue a SECURITY SET PASSWORD command  to change  the values of Security Status (WORD 128, bits 3:1). 

 5. Verify that the content of Security Status  is changed successfully. If this criterion  is not 

fulfilled, test is marked as “FAILED”.  

6. To  verify  that  the  device  works  in  SEC5  state,  for  ATA  device,  issue  a  READ DMA command,  and  a  WRITE SECTOR  command.  For  ATAPI  device,  issue  an  INQUIRY command.  

7. Issue a COMRESET and complete OOB sequence.  

8. Issue an IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command.   9. Verify that the Security Feature Set remains enabled after a COMRESET. If this criterion 

is not fulfilled, test is marked as “FAILED”.  

10. Verify  that  the  content  of  Security  Status  is  maintained  after  a  COMRESET.  If  this criterion is not fulfilled, test is marked as “FAILED”.  

11. Verify that the device works in SEC5 state instead of SEC4 state. For ATA device, issue a READ DMA  command,  and  a  WRITE SECTOR  command.  For  ATAPI  device,  issue  an INQUIRY command. If this criterion is not fulfilled, test is marked as “FAILED”. 

 12. Restore the SECURITY PASSWORD. 

 Post Processing: (See section Post Processing on page 7.) 

1. Within the trace, verify that SSP is supported as reflected in the IDENTIFY (PACKET) DEVICE data (WORD 78, bit 6 set to 1).  

 2. WORD 82,  bit  1  should  also  be  set  to  1  to  reflect  the  device’s  support  for  Security 

Feature Set.  

3. WORD 85, bit 1  should also be  set  to 1  to  reflect  the device’s Security Feature Set  is enabled for the device. 

 4. Check  that  the SECURITY SET PASSWORD  command was executed  successfully  and 

the content within Security Status (WORD 128, bits 3:1) was changed from  its default values. 

 

Page 39: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  39  Digital MOI for JDSU Xgig Test Platform  

5. For  ATA  devices,  check  that  the  READ DMA  and  WRITE SECTOR  commands  were executed successfully. Successful completion of  these commands signifies  the device’s support for SEC5 state. 

 6. For  ATAPI  devices,  check  that  the  INQUIRY  command  was  executed  successfully. 

Successful completion of this command signifies the device’s support for SEC5 state.  

7. Verify  that COMRESET was  completed  successfully and  Security  Feature  Set  remained enabled,  while  the  content  of  Security  Status  was  unchanged  as  compared  to  that  before the COMRESET was issued. 

 8. For ATA devices, check again that the READ DMA and WRITE SECTOR commands were 

executed successfully. Successful completion of  these commands signifies  the device’s support for SEC5 state. 

 9. For ATAPI devices, check again that the INQUIRY command was executed successfully. 

Successful completion of this command signifies the device’s support for SEC5 state.  Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   SSP‐04: Set Address Max  Purpose:  To validate that a Device, when claiming support for Host Protected Area, will maintain the max address established by the SET MAX ADDRESS or SET MAX ADDRESS EX command after a COMRESET.  Note: This test is not applicable to ATAPI devices.  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009 

Page 40: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  40  Digital MOI for JDSU Xgig Test Platform  

  Discussion:  TBD  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the SSP-04 Test in the tool to activate this test.  3. Click the Start Tests Button. 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The SSP-04 Test does the following: 

1. Issue an IDENTIFY DEVICE command and check to see if SSP is supported (WORD 78, bit 6 set to 1) and Host Protected Area Feature Set  is supported  (WORD 82, bit 10 set to 1). If these bits are not set, mark test as “N/A”.  

2. If  48‐bit  Feature  Set  is  not  supported  (WORD 83,  bit  10  cleared  to  0),  issue  READ NATIVE MAX ADDRESS to get the 28‐bit Max User Accessible Address. 

 3. Issue SET MAX ADDRESS with new valid 28‐bit Max User Accessible Address. 

 4. Verify  that  the  content  of  the  28‐bit  Max  User  Accessible  Address  is  changed 

successfully. If this criterion is not fulfilled, test is marked as “FAILED”.  

5. If 48‐bit Feature Set is supported (WORD 83, bit 10 set to 1), issue READ NATIVE MAX ADDRESS EXT to get the 48‐bit Max User Accessible Address. 

 6. Issue SET MAX ADDRESS EXT with new valid 48‐bit Max User Accessible Address. 

 7. Verify  that  the  content  of  the  48‐bit  Max  User  Accessible  Address  is  changed 

successfully. If this criterion is not fulfilled, test is marked as “FAILED”.  

8. Issue a COMRESET and complete OOB sequence.  

Page 41: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  41  Digital MOI for JDSU Xgig Test Platform  

9. Issue an IDENTIFY DEVICE command.   

10. If 48‐bit Feature Set  is not  supported, verify  that  the  content of  the 28‐bit Max User Accessible Address  is maintained after a COMRESET.  If 48‐bit Feature Set  is supported, verify  that both  contents of  the 48‐bit and 28‐bit Max User Accessible Addresses are maintained  after  a  COMRESET.  If  this  criterion  is  not  fulfilled,  test  is  marked  as “FAILED”. 

 11. Restore Max User Accessible Address to its original values. 

 Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace, verify  that SSP  is  supported as  reflected  in  the IDENTIFY DEVICE data (WORD 78, bit 6 set to 1).  

2. WORD 82,  bit  10  should  also  be  set  to  1  to  reflect  the  device’s  support  for  Host Protected Area Feature Set. 

 3. Check that the SET MAX ADDRESS / SET MAX ADDRESS EXT command was executed 

successfully  and  contents  within  either  one  or  both  of  28‐bit  Max  User  Accessible Address (WORD 61:60) and 48‐bit Max User Accessible Address (WORD 103:100), were changed from their default values. 

 4. Verify that COMRESET completed successfully and contents within either one or both of 

28‐bit Max  User  Accessible  Address  (WORD 61:60)  and  48‐bit Max  User  Accessible Address (WORD 103:100), remained the same as before the COMRESET was issued. 

 Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.   

 2. Results for all the test cycles will be reported and the values used to determine overall 

pass/fail results. If the test fails any of the test cycles, the overall test result is failed.  Possible Problems:  See section Possible Problems on page 9.   SSP‐05: Set Features – Write Cache Enable/Disable  Purpose:  

Page 42: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  42  Digital MOI for JDSU Xgig Test Platform  

To validate that a Device, when claiming support for WRITE CACHE, will maintain the value of the write cache after a COMRESET has been received.  Resource Requirements:   See section Resource Requirements on page 6. Last Modification:  June 15, 2009   Discussion:  TBD  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the SSP-05 Test in the tool to activate this test.  3. Click the Start Tests Button. 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The SSP-05 Test does the following: 

1. Issue an IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command and  check  to  see  if  SSP  is  supported  (WORD 78, bit 6 set  to 1)  and Write Cache  is supported (WORD 82, bit 5 set to 1). If these bits are not set, mark test as “N/A”. 

 2. Check Write Cache’s setting (WORD 85, bit 5).  

 3. If Write  Cache  is  enabled,  issue  SET FEATURES  to  disable Write  Cache. Otherwise, 

issue SET FEATURES to enable Write Cache.  4. Verify that Write Cache’s setting is changed successfully. If this criterion is not fulfilled, 

test is marked as “FAILED”.  

5. Issue a COMRESET and complete OOB sequence.  

Page 43: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  43  Digital MOI for JDSU Xgig Test Platform  

6. Issue an IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command and verify that Write Cache’s setting is maintained after a COMRESET. If this criterion is not fulfilled, test is marked as “FAILED”.  

7. Restore Write Cache’s setting to its original value.   Post Processing: (See section Post Processing on page 7.) 

1. Within the trace, verify that SSP is supported as reflected in the IDENTIFY (PACKET) DEVICE data (WORD 78, bit 6 set to 1).   

2. WORD 82, bit 5 should also be set to 1 to reflect the device’s support for Write Cache  

3. Check that the SET FEATURES command was executed successfully and Write Cache’s setting (WORD 85, bit 5) was toggled. 

 4. Verify that COMRESET was completed successfully and Write Cache’s setting remained 

the same as before the COMRESET was issued.  Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   SSP‐06: Set Features – Set Transfer Mode  Purpose:  To validate that a Device, will maintain Multiword DMA and Ultra DMA mode settings after a COMRESET has been received.  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   

Page 44: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  44  Digital MOI for JDSU Xgig Test Platform  

Discussion:  TBD  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

  

Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the SSP-06 Test in the tool to activate this test.  3. Click the Start Tests Button. 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The SSP-06 Test does the following: 

1. Issue an IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command and check to see  if SSP  is supported (WORD 78, bit 6 set to 1).  If this criterion  is not met, mark test as “N/A”. 

 2. Check  the Multiword DMA Mode  Support  (Word 63, bits 2:0) and   Multiword DMA 

Mode Selected (WORD 63, bits 10:8).  

3. If Multiword DMA transfer is supported, issue SET FEATURES to change the content of Multiword DMA Mode Selected. 

 4. Verify that the content in Multiword DMA Mode Selected is successfully changed. If this 

criterion is not fulfilled, test is marked as “FAILED”.  5. Issue a COMRESET and complete OOB sequence. 

 6. Verify  that  the  content  in  Multiword  DMA  Mode  Selected  is  maintained  after  a 

COMRESET. If this criterion is not fulfilled, test is marked as “FAILED”.  

7. For  ATA  devices,  issue  a  READ DMA  command.  For  ATAPI  devices,  handle  the  reset condition accordingly and issue a READ 10 command.  

Page 45: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  45  Digital MOI for JDSU Xgig Test Platform  

8. Check the Ultra DMA Mode Support (Word 88, bits 6:0) and Ultra DMA Mode Selected (Word 88, bits 14:8).  

9. If Ultra DMA transfer is supported, issue SET FEATURES to change the content of Ultra DMA Mode Selected. 

 10. Verify  that  the  content  in  Ultra  DMA Mode  Selected  is  successfully  changed.  If  this 

criterion is not fulfilled, test is marked as “FAILED”. 11. Issue a COMRESET and complete OOB sequence. 

 12. Verify that the content in Ultra DMA Mode Selected is maintained after a COMRESET. If 

this criterion is not fulfilled, test is marked as “FAILED”.  

13. For  ATA  devices,  issue  a  READ DMA  command.  For  ATAPI  devices,  handle  the  reset condition accordingly and issue a READ 10 command. 

 14. Restore Multiword DMA Mode Selected / Ultra DMA Mode Selected to its original value. 

 Post Processing: (See section Post Processing on page 7.) 

1. Within the trace, verify that SSP is supported as reflected in the IDENTIFY (PACKET) DEVICE data (WORD 78, bit 6 set to 1).   

2. WORD 63, bits 10:8 should also be set to 1 to reflect the device’s support for Security Feature Set. 

 3. Check  that  the SET FEATURES  command was executed  successfully and  the  content 

within Multi‐Word DMA Mode  Selected  (WORD 63, bits 10:8)  or Ultra DMA Mode Selected (Word 88, bits 14:8) was changed from its default values. 

 4. Verify that COMRESET completed successfully and the content within Multi‐Word DMA 

Mode  Selected  and  Ultra  DMA  Mode  Selected  remained  the  same  as  before  the COMRESET was issued. 

 Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  

Page 46: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  46  Digital MOI for JDSU Xgig Test Platform  

See section Possible Problems on page 9.       SSP‐07: Set Features – Advanced Power Management Enable/Disable  Purpose:  To validate that a Device, that claims support for Advanced power Management, will maintain Advance Power Management setting after a COMRESET has been received. Note: This test is not applicable to ATAPI devices.  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  TBD  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the SSP-07 Test in the tool to activate this test.  3. Click the Start Tests Button. 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The SSP-07 Test does the following: 

1. Issue an IDENTIFY DEVICE command and check to see if SSP is supported (WORD 78, bit 6 set to 1) and Advanced Power Management is supported (WORD 83, bit 3 set to 1). If these bits are not set, mark test as “N/A”. 

 

Page 47: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  47  Digital MOI for JDSU Xgig Test Platform  

2. Check Advanced Power Management’s setting (WORD 86, bit 3). 

3. If  Advanced  Power  Management  is  enabled,  issue  SET FEATURES  to  disable  it. Otherwise, issue SET FEATURES to enable Advanced Power Management. 

4. Verify  that  contents  in  Advanced  Power Management  Enabled  and  Advanced  Power 

Management Level (WORD 91, bits 7:0) are successfully changed. If this criterion is not fulfilled, test is marked as “FAILED”. 

5. Issue a COMRESET and complete OOB sequence. 

6. Verify  that  contents  in  Advanced  Power Management  Enabled  and  Advanced  Power 

Management Level are maintained after a COMRESET. If this criterion is not fulfilled, test is marked as “FAILED”. 

7. Restore Advanced Power Management’s setting to its original value. 

 Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace, verify  that SSP  is  supported as  reflected  in  the IDENTIFY DEVICE data (WORD 78, bit 6 set to 1).   

2. WORD 83, bit 3  should  also be  set  to 1  to  reflect  the device’s  support  for Advanced Power Management. 

 3. Check  that  the  SET FEATURES  command  was  executed  successfully  and  Advanced 

Power Management’s  setting  (WORD 86, bit 3) was  toggled, while  the content within Advanced Power Management Level (WORD 91, bits 7:0) was changed from its default values. 

 4. Verify  that  COMRESET  completed  successfully  and  Advanced  Power  Management’s 

setting  and  Advanced  Power Management  Level  remained  the  same  as  before  the COMRESET was issued. 

 Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9. 

Page 48: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  48  Digital MOI for JDSU Xgig Test Platform  

   SSP‐08: Set Features – Read Look‐Ahead  Purpose:  To  validate  that  a Device,  that  claims  support  for  Read  Look‐Ahead, will maintain  the  Read Look‐Ahead settings after a COMRESET has been received.    Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  TBD  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the SSP-08 Test in the tool to activate this test.  3. Click the Start Tests Button. 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The SSP-08 Test does the following: 

1. Issue an IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command and check to see  if SSP  is supported (WORD 78, bit 6 set to 1) and Read Look‐Ahead Supported (WORD 82, bit 6 set to 1). If these bits are not set, mark test as “N/A”. 

 2. Check Read Look‐Ahead’s setting (WORD 85, bit 6).  

 3. If Read Look‐Ahead is enabled, issue SET FEATURES to disable it. Otherwise, issue SET

FEATURES to enable Read Look‐Ahead.  

Page 49: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  49  Digital MOI for JDSU Xgig Test Platform  

4. Verify  that  Read  Look‐Ahead’s  setting  is  successfully  changed.  If  this  criterion  is  not fulfilled, test is marked as “FAILED”. 

 5. Issue a COMRESET and complete OOB sequence. 

 6. Verify that Read Look‐Ahead’s setting is maintained after a COMRESET. If this criterion is 

not fulfilled, test is marked as “FAILED”.  

7. Restore Read Look‐Ahead’s setting to its original value.  Post Processing: (See section Post Processing on page 7.) 

1. Within the trace, verify that SSP is supported as reflected in the IDENTIFY (PACKET) DEVICE data (WORD 78, bit 6 set to 1).  

 2. WORD 82, bit 6 should also be set  to 1  to  reflect  the device’s support  for Read Look‐

Ahead.  

3. Check  that  the SET FEATURES  command was  executed  successfully  and Read  Look‐Ahead’s setting (WORD 85, bit 6) was toggled. 

 4. Verify that COMRESET completed successfully and Read Look‐Ahead’s setting remained 

the same as before the COMRESET was issued.  Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   SSP‐09: Set Features – Release Interrupt  Purpose:  To  validate  that  a  Device,  that  claims  support  for  Release  Interrupt,  will maintain  Release Interrupt setting after a COMRESET has been received.    Resource Requirements:   

Page 50: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  50  Digital MOI for JDSU Xgig Test Platform  

See section Resource Requirements on page 6.  Last Modification:  June 15, 2009 Discussion:  TBD  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the SSP-09 Test in the tool to activate this test.  3. Click the Start Tests Button. 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The SSP-09 Test does the following: 

1. Issue an IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command and check to see if SSP is supported (WORD 78, bit 6 set to 1) and Release Interrupt is supported (WORD 82, bit 7 set to 1). If these are not set, mark test as “N/A”. 

 2. Check Release Interrupt’s setting (WORD 85, bit 7). 

 3. If Release Interrupt is enabled, issue SET FEATURES to disable it. Otherwise, issue SET

FEATURES to enable Release Interrupt.  

4. Verify  that  Release  Interrupt’s  setting  is  successfully  changed.  If  this  criterion  is  not fulfilled, test is marked as “FAILED”. 

 5. Issue a COMRESET and complete OOB sequence. 

 6. Verify that Release Interrupt’s setting is maintained after a COMRESET. If this criterion is 

not fulfilled, test is marked as “FAILED”.  

7. Restore Release Interrupt’s setting to its original value.  Post Processing: (See section Post Processing on page 7.) 

Page 51: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  51  Digital MOI for JDSU Xgig Test Platform  

1. Within the trace, verify that SSP is supported as reflected in the IDENTIFY (PACKET) DEVICE data (WORD 78, bit 6 set to 1).   

2. WORD 82,  bit  7  should  also  be  set  to  1  to  reflect  the  device’s  support  for  Release Interrupt. 

 3. Check  that  the  SET FEATURES  command  was  executed  successfully  and  Release 

Interrupt’s setting (WORD 85, bit 7) was toggled.  

4. Verify that COMRESET completed successfully and Release Interrupt’s setting remained the same as before the COMRESET was issued. 

 Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   SSP‐10: Set Features – Service Interrupt  Purpose:  To  validate  that  a  Device,  that  claims  support  for  Service  Interrupt,  will  maintain  Service Interrupt, setting after a COMRESET has been received.    Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  TBD  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: 

Page 52: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  52  Digital MOI for JDSU Xgig Test Platform  

Start Test: 1. Enable Xgig tracing between Host and Device (Optional).  2. Click the SSP-10 Test in the tool to activate this test.  3. Click the Start Tests Button. 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The SSP-10 Test does the following: 

1. Issue an IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command and check to see if SSP is supported (WORD 78, bit 6 set to 1) and Service Interrupt is supported (WORD 82, bit 8 set to 1). If these bits are not set, mark test as “N/A”. 

 2. Check Service Interrupt’s setting (WORD 85, bit 8).  3. If Service Interrupt is enabled, issue SET FEATURES to disable it. Otherwise, issue SET

FEATURES to enable Service Interrupt.  

4. Verify  that  Service  Interrupt’s  setting  is  successfully  changed.  If  this  criterion  is  not fulfilled, test is marked as “FAILED”. 

 5. Issue a COMRESET and complete OOB sequence. 

 6. Verify that Service Interrupt’s setting is maintained after a COMRESET. If this criterion is 

not fulfilled, test is marked as “FAILED”.  

7. Restore Service Interrupt’s setting to its original value.  Post Processing: (See section Post Processing on page 7.) 

1. Within the trace, verify that SSP is supported as reflected in the IDENTIFY (PACKET) DEVICE data (WORD 78, bit 6 set to 1).   

2. WORD 82,  bit  8  should  also  be  set  to  1  to  reflect  the  device’s  support  for  Service Interrupt.  

3. Check  that  the  SET FEATURES  command  was  executed  successfully  and  Service Interrupt’s setting (WORD 85, bit 8) was toggled..  

Page 53: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  53  Digital MOI for JDSU Xgig Test Platform  

4. Verify that COMRESET completed successfully and Service  Interrupt’s setting remained the same as before the COMRESET was issued. 

  Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   SSP‐11: Set Multiple Mode  Purpose:  To validate  that a Device,  that claims  support  for Set Multiple Mode will maintain block  size established by Multiple Mode command setting after a COMRESET has been received. Note: This test is not applicable to ATAPI devices.  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  TBD  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  

2. Click the SSP-11 Test in the tool to activate this test.  3. Click the Start Tests Button. 

 

Page 54: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  54  Digital MOI for JDSU Xgig Test Platform  

4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to analyze the Xgig trace result of this test (Optional). 

  The SSP-11 Test does the following: 

1. Issue  an  IDENTIFY DEVICE (ATA)  command  and  check  to  see  if  SSP  is  supported (WORD 78, bit 6 set to 1) and Multiple Logical Setting is valid (WORD 59, bit 8 set to 1). If these bits are not set, mark test as “N/A”. 

 2. Check the Maximum Logical Sector Per Read/Write Multiple (WORD 47, bits 7:0) for 

non‐zero values.   3. Issue a SET MULTIPLE command to alter device block size from the value reported in 

Maximum Logical Sector Per Read/Write Multiple.   4. Verify that the content in Logical Sector Per Read/Write Multiple (WORD 59, bits 7:0) is 

successfully  changed  resulting  from  the SET MULTIPLE  command.  If  this  criterion  is not fulfilled, test is marked as “FAILED”. 

 5. Issue a COMRESET and complete OOB sequence. 

 6. Verify that the content  in Logical Sector Per Read/Write Multiple  is maintained after a 

COMRESET. If this criterion is not fulfilled, test is marked as “FAILED”.  7. Restore Logical Sector Per Read/Write Multiple to its original values. 

 Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace, verify  that SSP  is  supported as  reflected  in  the IDENTIFY DEVICE data (WORD 78, bit 6 set to 1).   

2. WORD 59, bit 8 should also be set to 1 to reflect that Multiple Logical Setting is valid.  

3. Check  that  the SET MULTIPLE  command was executed  successfully and  the  content within  Maximum  Logical  Sector  Per  Read/Write  Multiple  (WORD 47,  bits  7:0)  was changed from its default values.  

4. Verify  that  COMRESET  completed  successfully  and  the  content  of Maximum  Logical Sector Per Read/Write Multiple was unchanged as compared to before the COMRESET was issued. 

 Observable Results:  (See section Observable Results on page 7.) 

Page 55: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  55  Digital MOI for JDSU Xgig Test Platform  

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.   

 2. Results for all the test cycles will be reported and the values used to determine overall 

pass/fail results. If the test fails any of the test cycles, the overall test result is failed.  Possible Problems:  See section Possible Problems on page 9.   SSP‐12: Set Features – Write‐Read‐Verify  Purpose:  To validate that a Device, that claims support for Write‐Read‐Verify will maintain Write‐Read‐Verify command settings after a COMRESET has been received. Note: This test is not applicable to ATAPI devices.  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  TBD  Test Setup:  See section Appendix A: Test Setup Procedure on page 83.  Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the SSP-12 Test in the tool to activate this test.  3. Click the Start Tests Button. 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The SSP-12 Test does the following: 

Page 56: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  56  Digital MOI for JDSU Xgig Test Platform  

1. Issue  an  IDENTIFY DEVICE (ATA)  command  and  check  to  see  if  SSP  is  supported (WORD 78, bit 6 set to 1) and WORD 120:119 are valid (WORD 86, bit 15 set to 1). If these bits are not set, mark test as “N/A”. 

 2. Check Write‐Read‐Verify Feature Set  is  supported  (WORD 119, bit 1  set  to 1).  If  this 

criterion is not met, mark test as “N/A”.  3. Check Write‐Read‐Verify Feature Set’s setting (WORD 120, bit 1).  

 4. If  Write‐Read‐Verify  Feature  Set  is  enabled,  issue  SET FEATURES  to  disable  it. 

Otherwise, issue SET FEATURES to enable Write‐Read‐Verify Feature Set.  

5. Verify  that  contents  in  Write‐Read‐Verify  Feature  Set  Enabled,  Write‐Read‐Verify Current mode (WORD 220, bits 7:0) and Write‐Read‐Verify Sector Count Mode 3 Only (WORD 211:210),  are  successfully  changed  resulting  from  the  SET FEATURES command. If thisthese criteria are not fulfilled, test is marked as “FAILED”. 

 6. Issue a COMRESET and complete OOB sequence. 

 7. Verify  that  contents  in  Write‐Read‐Verify  Feature  Set  Enabled,  Write‐Read‐Verify 

Current mode and Write‐Read‐Verify Sector Count Mode 3 Only are maintained after a COMRESET. If this criteria these criterion are not fulfilled, test is marked as “FAILED”. 

 8. Test device’s  support  for multiple Write‐Read‐Verify Modes.  Issue SET FEATURES  to 

enable Write‐Read‐Verify into Mode 0, Mode 1, Mode 2 and Mode 3.  

9. In  each  iteration,  after  calling  SET FEATURES,  verify  that  the  change  has  been successful and  issue a COMRESET. Verify that the content  in Write‐Read‐Verify Current Mode setting  is maintained after the COMRESET.  If this criterion  is not  fulfilled, test  is marked as “FAILED”. 

 10. Test device’s support  for multiple sector count when using Write‐Read‐Verify Mode 3. 

Issue SET FEATURES to enable Write‐Read‐Verify into Mode 3. Iterate this step with 4 different values of Mode 3 sector count. 

 11. In  each  iteration,  after  calling  SET FEATURES,  verify  that  the  change  has  been 

successful and  issue a COMRESET. Verify  that  the  content  in Write‐Read‐Verify Sector Count Mode 3 Only  setting  is maintained  after  the COMRESET.  If  this  criterion  is not fulfilled, test is marked as “FAILED”. 

 12. Restore Write‐Read‐Verify settings to its original values. 

Page 57: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  57  Digital MOI for JDSU Xgig Test Platform  

 Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace, verify  that SSP  is  supported as  reflected  in  the IDENTIFY DEVICE data (WORD 78, bit 6 set to 1). 

2. WORD 86,  bit  15  should  also  be  set  to  1  to  reflect  that  the  content  within  WORD 120:119 is valid. 

 3. WORD 119, bit 1 should also be set to 1 to reflect the device’s support for Write‐Read‐

Verify Feature Set.  

4. Check  that  the  SET FEATURES  command was  executed  successfully  and  the Write‐Read‐Verify setting (WORD 120, bit 1) was toggled, while contents of Write‐Read‐Verify Current Mode (WORD 220, bits 7:0) and Write‐Read‐Verify Sector Count Mode 3 Only (WORD 211:210) are changed from their default values. 

 5. Verify  that COMRESET  completed  successfully  and  contents  of  the Write  Read Verify 

setting, Write‐Read‐Verify Current Mode and Write‐Read‐Verify Sector Count Mode 3 Only remained the same as before the COMRESET was issued. 

 6. Perform similar verification for repeated portions within this test. 

 Observable Results:  (See section Observable Results on page 7.) 

3. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

4. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   IPM‐01: Partial State Exit Latency (Host‐Initiated)  Purpose:  To validate that a Device and corresponding Host exit  latency from the partial state shall start within 10 microseconds from the COMWAKE receipt. For consistency, this test is executed a total of 10 times. Note: The Host side testing is not supported by this MOI.  Status: Informative 

Page 58: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  58  Digital MOI for JDSU Xgig Test Platform  

 Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  TBD  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the IPM-01 Test in the tool to activate this test.  3. Click the Start Tests Button. (This test is automatically executed 10 times) 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The IPM-01 Test does the following: 

1. Issue an IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command and check to see if HIPM is supported (WORD 76, bit 9 is set to 1). If not, mark test as “N/A”. 

 2. Issue PMREQ_P primitives and obtain device response. 

 3. Issue COMWAKE and wait for complete wake of device. 

 4. Verify that Partial wake sequence completion is within 10 microseconds after COMWAKE 

is transmitted by host. If this criterion is not fulfilled, test is marked as “FAILED”.  

5. Issue IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command.   Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace,  verify  that  HIPM  is  supported  as  reflected  in  the  IDENTIFY (PACKET) DEVICE data (WORD 76, bit 9 set to 1).   

Page 59: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  59  Digital MOI for JDSU Xgig Test Platform  

2. Check  that PMREQ_P primitives were  successfully  issued by host,  followed by  success completion of COMWAKE sequence. 

 3. Verify that the device responded COMWAKE within a window of 10 microseconds upon 

receiving COMWAKE from host.  

4. Check that the IDENTIFY (PACKET) DEVICE command is completed successfully.  Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   IPM‐02: Slumber State Exit Latency (Host‐Initiated)  Purpose: To validate  that Device exit  latency  from  the  slumber  state  shall  start within 10 milliseconds from the COMWAKE receipt. For consistency, this test is executed a total of 10 times. Note: The Host side testing is not supported by this MOI.  Status: Informative  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  TBD  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

Page 60: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  60  Digital MOI for JDSU Xgig Test Platform  

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the IPM-02 Test in the tool to activate this test.  3. Click the Start Tests Button. (This test is automatically executed 10 times) 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional). The IPM-02 Test does the following: 

1. Issue an IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command and check to see  if HIPM  is supported (WORD 76 bit 9  is set to 1). If not, mark test as “N/A”. 

 2. Issue PMREQ_S primitives and receive device response. 

 3. Issue COMWAKE and wait for complete wake of device. 

 4. Verify that Slumber wake sequence completion is within 10 milliseconds after COMWAKE 

is transmitted by host. If this criterion is not fulfilled, test is marked as “FAILED”.  

5. Issue IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command.   Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace,  verify  that  HIPM  is  supported  as  reflected  in  the  IDENTIFY (PACKET) DEVICE data (WORD 76, bit 9 set to 1).   

 2. Check  that PMREQ_S primitives were  successfully  issued by host,  followed by  success 

completion of COMWAKE sequence.  

3. Verify  that  the device  responded COMWAKE within  a window of 10 milliseconds upon receiving COMWAKE from host. 

 4. Check that the IDENTIFY (PACKET) DEVICE command is completed successfully. 

 Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 

Page 61: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  61  Digital MOI for JDSU Xgig Test Platform  

Possible Problems:  See section Possible Problems on page 9.      IPM‐03: Speed Matching Upon Resume (Host‐Initiated)  Purpose:  To validate that Device signaling speed upon returning from the slumber or partial state shall match the signaling speed prior to the COMWAKE receipt.  If the Device claims multiple speeds, then  this  test must  be  run  for  each  supported  signaling  speed.  For  consistency,  this  test  is executed a total of 10 times for each supporting signaling speed. Note: The Host side testing is not supported by this MOI.  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  TBD  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the IPM-03 Test in the tool to activate this test.  3. Click the Start Tests Button. (This test is automatically executed 10 times) 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The IPM-03 Test does the following: 

Page 62: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  62  Digital MOI for JDSU Xgig Test Platform  

1. Issue an IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command and check to see  if HIPM  is supported (WORD 76 bit 9  is set to 1). If not, mark test as “N/A”.  

2. Set interface speed to the lowest supported speed.   

3. Issue PMREQ_P primitives and receive device response.  

4. Issue COMWAKE and wait for complete wake of Device. 5. Verify  that  the  interface  speed matches  the  interface  speed  prior  to  entering  Partial 

state. If this criterion is not fulfilled, test is marked as “FAILED”.  

6. Verify  that  PMACK  or  PMNAK  primitives  are  returned  after  PMREQ_P  primitives  are issued. If this criterion is not fulfilled, test is marked as “FAILED”. 

 7. The test is repeated with PMREQ_S primitives being issued. 

 8. If the device supports multiple Serial ATA  interface speed, this test  is repeated with all 

supported interface speeds.  Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace,  verify  that  HIPM  is  supported  as  reflected  in  the  IDENTIFY (PACKET) DEVICE data (WORD 76, bit 9 set to 1). 

 2. Check  that PMREQ_P primitives were  successfully  issued by host,  followed by device’s 

response of PMACK or PMNAK primitives.  

3. Check for successful completion of COMWAKE sequence, and the  interface speed at the start of the test must match with the interface speed after the COMWAKE sequence. 

 4. Perform similar verification for repeated portions within this test, where the PMREQ_S 

primitives are issued by the host.  Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  

Page 63: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  63  Digital MOI for JDSU Xgig Test Platform  

See section Possible Problems on page 9.        IPM‐04: NAK of Requests When Support Not Indicated  Purpose:  To validate that when a Device doesn’t support host interface power management and receives a PMREQ_S or PMREQ_P, the Device should response with a PMNAK. For consistency, this test is executed a total of 10 times. Note: The Host side testing is not supported by this MOI.  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  July 29, 2009   Discussion:  TBD  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the IPM-04 Test in the tool to activate this test.  3. Click the Start Tests Button. (This test is automatically executed 10 times) 

 The IPM-04 Test does the following: 

1. Issue an IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command and  check  to  see  if HIPM  is  not  supported  (WORD 76  bit 9  is  cleared  to  0).  If  it  is supported, mark test as “N/A”. 

 2. Issue PMREQ_P primitives and receive device response. 

Page 64: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  64  Digital MOI for JDSU Xgig Test Platform  

 3. Verify that PMACK primitives are not received after PMREQ_P primitives are sent. If this 

criterion is not fulfilled, test is marked as “FAILED”. If PMNAK primitives are received or there is no response from drive, the test result is a “PASSED”. 

 4. The test is repeated with PMREQ_S primitives being issued. 

  Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace,  verify  that  HIPM  is  not  supported  as  reflected  in  the  IDENTIFY (PACKET) DEVICE data (WORD 76, bit 9 cleared to 0). 

 2. Check that PMREQ_P primitives were successfully issued by host. 

 3. Verify that the device does not respond with PMACK primitives.  If there  is no response 

from the drive, the test result is still a “PASSED”.  

4. Perform similar verification for repeated portions within this test, where the PMREQ_S primitives are issued by the host. 

 Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   IPM‐05: Response to PMREQ_P  Purpose:  To  validate  that when  a Device  supports  host  interface  power management  and  receives  a PMREQ_P,  it  sends  the  correct  responses  that  include:  sends  between  4  and  16  PMACK primitives  and places  the device  in Partial  state, or  it  sends PMNAK responses until SYNC  is received, with no power transition state change. For consistency, this test is executed a total of 10 times. Note: The Host side testing is not supported by this MOI.  

Page 65: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  65  Digital MOI for JDSU Xgig Test Platform  

Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  TBD  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the IPM-05 Test in the tool to activate this test.  3. Click the Start Tests Button. (This test is automatically executed 10 times) 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The IPM-05 Test does the following: 

1. Issue an IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command and check to see  if HIPM  is supported (WORD 76 bit 9  is set to 1). If not, mark test as “N/A”. 

 2. Issue PMREQ_P primitives and receive device response. 

 3. Issue COMWAKE and wait for complete wake of Device. 

 4. Verify that either PMNAK or more than 4 PMACK primitives are received, after PMREQ_P 

primitives are sent. If this criterion is not fulfilled, test is marked as “FAILED”.  Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace,  verify  that  HIPM  is  supported  as  reflected  in  the  IDENTIFY (PACKET) DEVICE data (WORD 76, bit 9 set to 1).   

2. Check  that PMREQ_P primitives were  successfully  issued by host,  followed by device’s response of either PMNAK primitives, or 4 or more PMACK primitives. 

 

Page 66: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  66  Digital MOI for JDSU Xgig Test Platform  

3. Check for successful completion of COMWAKE sequence.  Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

Possible Problems:  See section Possible Problems on page 9.   IPM‐06: Response to PMREQ_S  Purpose:  To  validate  that when  a Device  supports  host  interface  power management  and  receives  a PMREQ_S,  it  sends  the  correct  responses  that  include:  sends  between  4  and  16  PMACK primitives and places  the device  in Slumber  state, or  it  sends PMNAK  responses until SYNC  is received, with no power transition state change. For consistency, this test is executed a total of 10 times. Note: The Host side testing is not supported by this MOI.  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  TBD  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the IPM-06 Test in the tool to activate this test.  3. Click the Start Tests Button. (This test is automatically executed 10 times) 

 

Page 67: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  67  Digital MOI for JDSU Xgig Test Platform  

4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to analyze the Xgig trace result of this test (Optional). 

 The IPM-06 Test does the following: 

1. Issue an IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command and check to see  if HIPM  is supported (WORD 76 bit 9  is set to 1). If not, mark test as “N/A”. 

 2. Issue PMREQ_S primitives and receive device response. 

 3. Issue COMWAKE and wait for complete wake of Device. 

 4. Verify that either PMNAK or more than 4 PMACK primitives are received, after PMREQ_S 

primitives are sent. If this criterion is not fulfilled, test is marked as “FAILED”.  Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace,  verify  that  HIPM  is  supported  as  reflected  in  the  IDENTIFY (PACKET) DEVICE data (WORD 76, bit 9 set to 1).   

2. Check  that PMREQ_S primitives were  successfully  issued by host,  followed by device’s response of either PMNAK primitives, or 4 or more PMACK primitives. 

 3. Check for successful completion of COMWAKE sequence. 

 Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   IPM‐07: Device Default Setting For Device Initiated Requests  Purpose:  To validate that when a Device supports host interface power management and this feature is disabled  via  the  SET FEATURES  command  by  default,  then  the  Device  shall  not  issue  any 

Page 68: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  68  Digital MOI for JDSU Xgig Test Platform  

Partial/Slumber  requests  until  the  feature  is  enabled  again.  For  consistency,  this  test  is executed a total of 10 times. Note: The Host side testing is not supported by this MOI.  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  TBD  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the IPM-07 Test in the tool to activate this test.  3. Click the Start Tests Button. (This test is automatically executed 10 times) 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The IPM-07 Test does the following: 

1. Power cycle device.  2. Issue an IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command 

and check to see  if DIPM  is supported (WORD 78 bit 3  is set to 1). If not, mark test as “N/A”. 

 3. Check that DIPM Enabled (WORD 79, bit 3) is cleared to 0.  

 4. Issue a SET FEATURES command with Sector Count = 03h and Features = 10h

to enable DIPM.  5. Verify that DIPM is successfully enabled. If this criterion is not fulfilled, test is marked as 

“FAILED”.  

Page 69: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  69  Digital MOI for JDSU Xgig Test Platform  

6. Issue a COMRESET and complete OOB sequence.  

7. Verify  that  DIPM  Enabled  is  cleared  to  0  after  a  COMRESET.  If  this  criterion  is  not fulfilled, test is marked as “FAILED”. 

 Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace,  verify  that  DIPM  is  supported  as  reflected  in  the  IDENTIFY (PACKET) DEVICE data (WORD 78, bit 3 set to 1).   

2. WORD 79, bit 3 should also be cleared to 0 to reflect that by default, DIPM  is disabled for  the device. 

 3. Check  that  the  SET FEATURES  command  was  executed  successfully  and  DIPM  is 

enabled for the device.  

4. Verify  that  COMRESET  is  completed  successfully  and  DIPM  is  disabled  after  the COMRESET. 

 Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   IPM‐08: Device Initiated Power Management Enable/Disable  Purpose:  To validate that when a Device’s power management has been disabled via the SET FEATURES command,  the  Device  shall  not  issue  Partial/Slumber  requests.  For  consistency,  this  test  is executed a total of 10 times. Note: The Host side testing is not supported by this MOI.  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009 

Page 70: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  70  Digital MOI for JDSU Xgig Test Platform  

  Discussion:  TBD  Test Setup:  See section Appendix A: Test Setup Procedure on page 83.    Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the IPM-08 Test in the tool to activate this test. 

 3. Click the Start Tests Button. (This test is automatically executed 10 times) 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The IPM-08 Test does the following: 

1. Power cycle device.  

2. Issue an IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command and check to see  if DIPM  is supported (WORD 78 bit 3  is set to 1). If not, mark test as “N/A”. 

 3. Check that DIPM Enabled (WORD 79, bit 3) is cleared to 0.  

 4. Issue a SET FEATURES command with Sector Count = 03h and Features = 10h

to enable DIPM.  

5. Verify that DIPM is successfully enabled. If this criterion is not fulfilled, test is marked as “FAILED”. 

 6. Leave the device idle and wait for PMREQ_P or PMREQ_S primitives for 10 seconds. 

 7. If  no  PMREQ_P  or  PMREQ_S  primitives  have  been  received,  issue  a  STANDBY

IMMEDIATE command. Leave the device  idle and wait for these primitives for another 10 seconds. 

 

Page 71: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  71  Digital MOI for JDSU Xgig Test Platform  

8. Issue COMWAKE and wait for complete wake of device.  

9. Issue a SET FEATURES command with Sector Count = 03h and Features = 90h to disable DIPM. 

 10. Verify that DIPM is successfully disabled. If this criterion is not fulfilled, test is marked as 

“FAILED”.  

11. Leave the device  idle and verify that no PMREQ_P or PMREQ_S primitives are received within 10 seconds. If this criterion is not fulfilled, test is marked as “FAILED”. 

 12. Issue a STANDBY IMMEDIATE command. Leave the device idle and wait for another 10 

seconds. Verify that no PMREQ_P or PMREQ_S primitives are received within this period of time. If this criterion is not fulfilled, test is marked as “FAILED”. 

 Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace,  verify  that  DIPM  is  supported  as  reflected  in  the  IDENTIFY (PACKET) DEVICE data (WORD 78, bit 3 set to 1).   

2. WORD 79, bit 3 should also be cleared to 0 to reflect that by default, DIPM  is disabled for  the device. 

 3. Check  that  the  SET FEATURES  command  was  executed  successfully  and  DIPM  is 

enabled for the device.  

4. Verify  that either PMREQ_P or PMREQ_S primitives were  issued by  the device after  it went idle. 

 5. Check for successful completion of COMWAKE sequence. 

 6. Check  that  the  SET FEATURES  command  was  executed  successfully  and  DIPM  is 

disabled for the device.  

7. Verify that neither PMREQ_P nor PMREQ_S primitives were issued by the device after it went idle. 

 Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.  

Page 72: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  72  Digital MOI for JDSU Xgig Test Platform  

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.    IPM‐09: Partial State Exit Latency (Device‐Initiated)   Purpose:  To  validate  that  a  Device  and  Host  exit  latency  from  partial  state  shall  start  within  10 microseconds from a COMWAKE from the host. This test is executed a total of 10 times. Note: The Host side testing is not supported by this MOI.  Status: Informative  Resource Requirements:   See section Resource Requirements on page 6. Last Modification:  June 15, 2009   Discussion:  To determine if the Device latency from a partial wake sequence can be completed within the 10‐microsecond window from COMWAKE receipt.   Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the IPM-09 Test in the tool to activate this test.  3. Click the Start Tests Button. (This test is automatically executed 10 times) 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The IPM-09 Test does the following: 

Page 73: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  73  Digital MOI for JDSU Xgig Test Platform  

1. Issue an IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command and check to see  if DIPM  is supported (WORD 78 bit 3  is set to 1). If not, mark test as “N/A”. 

 2. Issue SET FEATURES to enable DIPM (WORD 79, bit 3  is set to 1) and verify that  it  is 

successfully enabled.  

3. Leave the device idle and wait for PMREQ_P primitives for 10 seconds.  

4. If no PMREQ_P primitives have been received, issue a STANDBY IMMEDIATE command. Leave the device idle and wait for this primitive for another 10 seconds.  

5. Issue COMWAKE and wait for complete wake of device.  

6. Verify that Partial wake sequence completion is within 10 microseconds after COMWAKE is transmitted by host. If this criteria is not fulfilled, test is marked as “FAILED”.  

7. Issue  an  IDENTIFY DEVICE (ATA)  or  IDENTIFY PACKET DEVICE (ATAPI) command. 

 Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace,  verify  that  DIPM  is  supported  as  reflected  in  the  IDENTIFY (PACKET) DEVICE data (WORD 78, bit 3 set to 1).   

2. Check  that  the  SET FEATURES  command  was  executed  successfully  and  DIPM  is enabled (WORD 79, bit 3 is set to 1) for the device. 

 3. Verify that PMREQ_P primitives were issued by the device after it went idle. 

 4. Check  for  successful  completion  of  COMWAKE  sequence  and  COMWAKE  response  from 

device is within a window of 10 microseconds upon receiving COMWAKE from host.  

5. Check that the IDENTIFY (PACKET) DEVICE command completed successfully.  Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  

Page 74: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  74  Digital MOI for JDSU Xgig Test Platform  

See section Possible Problems on page 9.   IPM‐10: Slumber State Exit Latency (Device‐Initiated)   Purpose:  To  validate  that  a  Device  and  Host  exit  latency  from  partial  state  shall  start  within  10 milliseconds from a COMWAKE from the host. This test is executed 10 times. Note: The Host side testing is not supported by this MOI.   Status: Informative  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  To  determine  if  a  device  exit  latency  from  the  slumber  state  fails within  the  10‐millisecond window from the COMWAKE receipt from the host.  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the IPM-10 Test in the tool to activate this test.  3. Click the Start Tests Button. (This test is automatically executed 10 times) 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The IPM-10 Test does the following: 

1. Issue an IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command and check to see  if DIPM  is supported (WORD 78 bit 3  is set to 1). If not, mark test as “N/A”. 

 

Page 75: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  75  Digital MOI for JDSU Xgig Test Platform  

2. Issue SET FEATURES to enable DIPM (WORD 79, bit 3  is set to 1) and verify that  it  is successfully enabled. 

 3. Leave the device idle and wait for PMREQ_S primitives for 10 seconds. 

 4. If no PMREQ_S primitives have been received, issue a STANDBY IMMEDIATE command. 

Leave the device idle and wait for this primitive for another 10 seconds.   

5. Issue COMWAKE and wait for complete wake of device.  

6. Verify that Slumber wake sequence completion is within 10 milliseconds after COMWAKE is transmitted by host. If this criterion is not fulfilled, test is marked as “FAILED”. 

 7. Issue  an  IDENTIFY DEVICE (ATA)  or  IDENTIFY PACKET DEVICE (ATAPI) 

command.  Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace,  verify  that  DIPM  is  supported  as  reflected  in  the  IDENTIFY (PACKET) DEVICE data (WORD 78, bit 3 set to 1). 

 2. Check  that  the  SET FEATURES  command  was  executed  successfully  and  DIPM  is 

enabled (WORD 79, bit 3 is set to 1) for the device.  

3. Verify that PMREQ_S primitives were issued by the device after it went idle.  

4. Check  for  successful  completion  of  COMWAKE  sequence  and  COMWAKE  response  from device is within a window of 10 milliseconds upon receiving COMWAKE from host. 

 5. Check that the IDENTIFY (PACKET) DEVICE command completed successfully. 

 Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9. 

Page 76: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  76  Digital MOI for JDSU Xgig Test Platform  

  IPM‐11: Speed Matching Upon Resume (Device‐Initiated)   Purpose:  To validate that a Device signaling speed on returning from power management state matches the speed prior to entering power management mode.  This test is executed 10 times. Note: The Host side testing is not supported by this MOI.  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  Determine when communication with a device and then waits for it to a request power management capability. If none is detected, issue STANDBY IMMEDIATE command. Next, interface speed is verified to be the same as initial connection speed.  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  

2. Click the IPM-11 Test in the tool to activate this test.  3. Click the Start Tests Button. (This test is automatically executed 10 times) 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The IPM-11 Test does the following: 

1. Issue an IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command and check to see  if DIPM  is supported (WORD 78 bit 3  is set to 1). If not, mark test as “N/A”. 

 2. Set interface speed to the lowest supported speed.  

Page 77: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  77  Digital MOI for JDSU Xgig Test Platform  

3. Issue SET FEATURES to enable DIPM and verify that it is successfully enabled.  4. Leave the device idle and wait for PMREQ_P primitives for 10 seconds.   5. If no PMREQ_P primitives have been received, issue a STANDBY IMMEDIATE command. 

Leave the device idle and wait for this primitive for another 10 seconds.  6. Issue COMWAKE and wait for complete wake of device.  7. Verify  that  the  interface speed matches  the  interface speed prior  to entering Slumber 

state. If this criterion is not fulfilled, test is marked as “FAILED”.  8. Issue  an  IDENTIFY DEVICE (ATA)  or  IDENTIFY PACKET DEVICE (ATAPI) 

command.  9. The test is repeated with verification of receive of PMREQ_S primitive from device.  10. If the device supports multiple Serial ATA  interface speed, this test  is repeated with all 

supported interface speeds.  Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace,  verify  that  DIPM  is  supported  as  reflected  in  the  IDENTIFY (PACKET) DEVICE data (WORD 78, bit 3 set to 1).  

 2. Check  that  the  SET FEATURES  command  was  executed  successfully  and  DIPM  is 

enabled (WORD 79, bit 3 is set to 1) for the device.  

3. Check that PMREQ_P primitives were issued by the device after it went idle.  4. Check for successful completion of COMWAKE sequence, and the  interface speed at the 

start of the test must match with the interface speed after the COMWAKE sequence.  

5. Check that the IDENTIFY (PACKET) DEVICE command is completed successfully.  

6. Perform similar verification for repeated portions within this test, where the PMREQ_S primitive is issued by the host. 

 Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

Page 78: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  78  Digital MOI for JDSU Xgig Test Platform  

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   DOF‐01: Asynchronous Notification  Purpose:  To validate that a device supports Asynchronous Notification feature to send a notification to the host that the devices requires attention.  This feature should be enabled by the host before the device may set the N Bit to 1 in the Set Devices Bits FIS. This test will be executed 10 times. Note: This test is not applicable to ATA devices.  Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  July 29, 2009   Discussion:  This  test  ensures  that  the  Asynchronous Notification  feature  can  be  enabled,  disabled,  and verifies that the device emits the appropriate FIS messages when required.  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the DOF-01 Test in the tool to activate this test.  3. Click the Start Tests Button (This test is automatically executed 5 times). 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The DOF-01 Test does the following: 

1. Power cycle the Device  

Page 79: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  79  Digital MOI for JDSU Xgig Test Platform  

2. Issue  an  IDENTIFY PACKET DEVICE (ATAPI)  command  and  check  to  see  if Asynchronous Notification is supported (WORD 78, bit 5 is set to 1),). If not, mark test as “N/A”. 

 3. Next, the test tool does the following: 

• Check Asynchronous Notification Enabled (WORD 79, bit 5) in IDENTIFY PACKET DEVICE (ATAPI) is cleared to 0. 

 Enable Feature Test • Issue a SET FEATURES command (Sector Count = 05h, Features = 10h) to 

enable device support for Asynchronous Notification on the device.  • Verify that Asynchronous Notification is successfully enabled. If this criterion is 

not fulfilled, test is marked as “FAILED”. If it is fulfilled, do the following: i. Prompt the user to manually press the EJECT button on the ATAPI device 

to let the tray or the media out.  

ii. Verify that a Set Devices Bits FIS with Interrupt ‘I’ bit set to 1 and Notification ‘N’ bit set to 1, is received. If this criterion is not fulfilled, test is marked as “FAILED”. 

 iii. Issue a GET EVENT/STATUS NOTIFICATION command to acknowledge 

the notification.  

iv. Prompt  the  user  to manually  push  in  the media  or  press  the  EJECT button to let the tray in. 

 v. Verify that a Set Devices Bits FIS with Interrupt ‘I’ bit set to 1 and 

Notification ‘N’ bit set to 1, is received. If this criterion is not fulfilled, test is marked as “FAILED”. 

 vi. Issue a GET EVENT/STATUS NOTIFICATION command to acknowledge 

the notification.  Disable Feature Test: • Issue a SET FEATURES command (Sector Count = 05h, Features = 90h) to 

disable device support for Asynchronous Notification on the device.  • Verify that Asynchronous Notification is successfully disabled. If this criterion is 

not fulfilled, test is marked as “FAILED”. If it is fulfilled, do the following: 

Page 80: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  80  Digital MOI for JDSU Xgig Test Platform  

i. Prompt the user to manually press the EJECT button on the ATAPI device to let the tray or the media out. 

 ii. Verify that a Set Devices Bits FIS is not be received. If this criterion is not 

fulfilled, test is marked as “FAILED”.  

iii. Prompt the user to manually push in the media or press the EJECT button to let the tray in. 

 iv. Verify that a Set Devices Bits FIS is not received. If this criterion is not 

fulfilled, test is marked as “FAILED”.  Post Processing: (See section Post Processing on page 7.) 

1. Within the trace, verify that Asynchronous Notification  is supported as reflected  in the IDENTIFY PACKET DEVICE data (WORD 78, bit 5 set to 1). 

2. WORD 79, bit 5  should  also be  cleared  to 0  to  reflect  that by default, Asynchronous Notification is disabled for  the device. 

 3. Check that the SET FEATURES command was executed successfully and Asynchronous 

Notification is enabled for the device.  4. Verify that Set Device Bits FIS were received respectively after user ejected and returned 

the  tray of  the device. The  Set Device Bits  FIS  should be  received with  the  following criteria: • Interrupt ‘I’ bit = 1 • Notification ‘N’ bit = 1 

 5. Check  that  the  GET EVENT/STATUS NOTIFICATION  command  is  completed 

successfully.  

6. Check that the SET FEATURES command was executed successfully and Asynchronous Notification is disabled for the device. 

 7. Verify  that  Set Device  Bits  FIS were  not  received  respectively  after  user  ejected  and 

returned the tray of the device.  Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

Page 81: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  81  Digital MOI for JDSU Xgig Test Platform  

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   DOF‐02: Phy Speed Indicator  Purpose:  To validate  that  if a device claims  support  for multiple  signaling  speeds,  then  the Phy Speed Indicator, if supported, should be applied to all the speeds claimed by the device. Note: support for this feature  is optional, and  if WORD 77, bit 3  in IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command  is 0, then that  indicates that the device doesn’t support this feature. Resource Requirements:   See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion:  This  test  ensures  that  the  optional  Phy  Speed  Indicator  feature  is  supported  for  all  claimed speeds.  Test Setup:  See section Appendix A: Test Setup Procedure on page 83. 

 Test Procedure: Start Test: 

1. Enable Xgig tracing between Host and Device (Optional).  2. Click the DOF-02 Test in the tool to activate this test.  3. Click the Start Tests Button. 

 4. If  user  had  enabled  Xgig  tracing  before  hand,  Post  Processing  can  be  performed  to 

analyze the Xgig trace result of this test (Optional).  The DOF-02 Test does the following: 

Page 82: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  82  Digital MOI for JDSU Xgig Test Platform  

1. Issue an IDENTIFY DEVICE (ATA) or IDENTIFY PACKET DEVICE (ATAPI) command to  the  device  and  determine  the  Supported  Interface  Speed  Grades  (WORD 76,  bits 3:1). 

 2. Check the Negotiated Interface Speed (WORD 77, bits 3:1). 

 3. Check the current interface speed (MOI specific). 

 4. Verify that the current  interface speed matches the negotiated  interface speed.  If this 

criterion is not fulfilled, test is marked as “FAILED”.  

5. If the device supports multiple Serial ATA  interface speed, this test  is repeated with all supported interface speeds. 

 Post Processing: (See section Post Processing on page 7.) 

1. Within  the  trace,  check  the  Supported  Interface  Speed  Grades  as  reflected  in  the IDENTIFY (PACKET) DEVICE data (WORD 76, bit 3:1).  

2. Verify  that  the  Negotiated  Interface  Speed  (WORD 77,  bits  3:1)  matches  with  the current interface speed. 

 3. Perform similar verification for repeated portions within this test, where each different 

supported speed grades were used.  Observable Results:  (See section Observable Results on page 7.) 

1. Examine the test result section of the JDSU compliance test suite main window or view the test results by examining the log file.    

2. Results for all the test cycles will be reported and the values used to determine overall pass/fail results. If the test fails any of the test cycles, the overall test result is failed. 

 Possible Problems:  See section Possible Problems on page 9.   

Page 83: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  83  Digital MOI for JDSU Xgig Test Platform  

 

Appendix A: Test Setup Procedure  Purpose:  Test set up and configuration for performing SATA‐IO UTD testing on a target device using the JDSU compliance Xgig Testing Platform and SATA Compliance Suite Testing Solution.  Resource Requirements:  See section Resource Requirements on page 6.  Last Modification:  June 15, 2009   Discussion: The  test  procedures  use  a  HOST  Emulator  testing  platform  and  follow  the  1.4  testing specifications.  Validation of test results is accomplished via on‐screen test results, review of log file test results, and validation of HOST/Device traces. Note: the software tool determines the SATA  device  type  automatically  before  the  tests  are  executed.  As  a  result,  the  user must validate the device type before any tests are done.  Test Setup:  

1. Set up a host system  (Running MS Windows)  to support  JDSU’s Compliance Test Suite Software. The system must be attached to a functional LAN.  See Test Setup on page 5 for additional information.  

2. Install the JDSU Compliance Test Suite software on the host system using the standard JDSU product installer. The following default path is where the compliance application will be installed:  

c:\Program Files\JDSU\Xgig SATA CTS  

3. Attach  the  JDSU Xgig Test Platform  to  the LAN and  from  the host  system, verify connectivity to/from the LAN. 

 4. Connect  the DUT  to one of  the ports on  the  JDSU Xgig  Test Platform using  the 

SAS/SATA Mini horse tail cable.  5. Connect  the DUT  device  power  connector  to  a  standard  external  power  supply 

connector and power up the DUT, or connect the power controller unit to the DUT and  the  controlling  host  via USB  (See Appendix B  for  additional  information  on setting up the power controller). 

 

Page 84: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  84  Digital MOI for JDSU Xgig Test Platform  

6. As  a  supplemental  testing  component,  the  Xgig  Analyzer  application  should  be installed  on  the  host  system  and  traces  captured  during  each  testing  phase  to validate each test case. 

  

Test Procedure: 1. Start the JDSU Compliance Test Suite Software application by opening a command 

prompt window and typing:   c:\Program Files\JDSU\Xgig SATA CTS\tester.exe

 Once the application has started the following window will be displayed as shown in Figure 0‐1 below.  

 

 

Figure 0‐1: JDSU Compliance Testing Suite Main Window 

 

Page 85: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  85  Digital MOI for JDSU Xgig Test Platform  

2. Once the window above is shown, click the Setup button. A new dialog window will be displayed as shown in Figure 0‐2 below. Use this window to enter and select Xgig network configuration/target information. 

  

   

Figure 0‐2: Setup Dialog Window 

Enter the IP address of the Xgig system and then select the blade number, and finally the port number  where  the  target  device  is  attached.  Then,  click  the  OK  button  to  save  this configuration information.  As confirmation of your configuration, the Tester Info section of the main window is updated.  

3. Next,  click  the  Discover  button  to  automatically  determine  the  type  of  SATA device  connected  the  Xgig  system.    If  a  valid  device  is  found,  the  device model information is displayed in the Target Information section on the main window.  

 Note: You must discover a target device before any tests can be executed. If you try to start the tests before the target discovery is made, a dialog message window will be displayed as shown in Figure 0‐3. 

 

Page 86: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  86  Digital MOI for JDSU Xgig Test Platform  

 

Figure 0‐3: Discover Dialog Message 

 4. Click  the  Start  button  to  start  the  compliance  test  cycle.  Test  progress will  be 

displayed in the test result panel.  

 Observable Results:   

• The  test  results will  be  shown  in  the  test  result  pane.  Also,  the  test  result  file will capture the overall test status and each iteration results. 

 

Appendix B – Setting up the LabJack Device  To use the LabJack device to control power to the SATA target device, follow the steps below:  Note: You should only attempt to use a power supply that has been designed to accept a power toggle switch using the wiring specified below. If you attempt to use a power unit that has not been designed with a power  switch  in mind, you  risk causing  serious damage  to  the LabJack device and other components. Also serious  injury to  individuals or fire can result  if care  is not taken and/or connecting the LabJack to inappropriate power supply units.  To Setup the LabJack:  

• Install the JDSU Compliance Application using the standard product installer  

• Process to next section below “LabJack Connections”  

LabJack Connections 

Using Figure 5 as a guide, do the following: 

 • Using a standard USB cable, connect the host end to the JDSU Compliance host system 

and connect the other end to the LabJack device. Once this connection is made, the USB LED on the LabJack should illuminate. 

Page 87: SATA Digital Device MOI JDSU UTD1.4 1.00

 

  Serial ATA Logo Group  87  Digital MOI for JDSU Xgig Test Platform  

 • Connect the BLACK power control cable to the SGND terminal post on the LabJack. 

  

• Connect the GREEN power control cable to one of the FIO terminal posts, this terminal location should match the selection within the JDSU Compliance GUI configuration.  

• Plug the Power Supply into a house outlet.  

• The JDSU Compliance Application should now be able to control the power supply to the target device. 

 CTS Host Computer

Standard Power Supply

Power Plug

Target DeviceBlack

GreenFI07

SGND

 

Figure 4: LabJack Setup Diagram