sanyo hvac_catalog - achr news - air conditioning, · pdf file2 single split over 26000btu...

12
Air Conditioning & Heat Pump Products Preliminary Revised April ’06

Upload: buianh

Post on 30-Jan-2018

270 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: SANYO HVAC_Catalog - ACHR News - Air Conditioning, · PDF file2 Single split over 26000Btu (except 24KS62R) that operates in the A/C mode down to 0°F ambient temperature. SANYO Air

Air Conditioning & Heat Pump Products

Preliminary

Revised April ’06

Page 2: SANYO HVAC_Catalog - ACHR News - Air Conditioning, · PDF file2 Single split over 26000Btu (except 24KS62R) that operates in the A/C mode down to 0°F ambient temperature. SANYO Air

2Single split over 26000Btu (except 24KS62R) that operates in the A/C mode down to 0°F ambient temperature.

SANYO Air Conditioners & Heat Pumps Btu/h 9,000 12,000 18,000 24,000 26,000 30,000 36,000 42,000

AIR

CO

ND

ITIO

NER

WallMounted

CeilingSuspended

CeilingRecessed

ConcealedDuct

KS0971 KS1271 KS1872

MODEL (System)

Type Standard Low Ambient

KS2472 KS2462R KH2672R

MODEL (System)

TH3672R TH4272R

XH3672R XH4272R

UH3672R

WallMounted

CeilingSuspended

HEAT

PUM

P W

ITH

HEAT

ER

Outdoor

Outdoor

Outdoor

KH3672RKH3072R

TH2672R

XH3672R

UH2672R UH3672R

XH4272R

ConcealedDuct

CeilingRecessed

CeilingSuspended

WallMounted

HEA

T PU

MP

WIT

HO

UT

HEA

TER

KHS0971 KHS1271 KHS1872 KHS2472

MODEL (System) 09KHS71 12KHS71 18KHS72 24KHS72 26KH72R 26TH72R26XH72R 26UH72R

36KH72R 36TH72R36XH72R 36UH72R

42TH72R42XH72R30KH72R

C0971 CL0971 C1872 CL1872 C2472 CL2472 C3072R C3672R C4272R

TH4272RTH3672R

TH2672R

XH2672R

UH2672R

CH0971 CH1271 CH1872 CH2472 CH3072R

KHH2672R

26KHH72R26THH72R

36THH72R

THH3672RTHH2672R

CH2672R

09KS71 09KLS71 12KS71 12KLS71 18KS72 18KLS72 24KS72 24KLS7224KS62R 24KLS62R

26K72R 26T72R26X72R 26U72R

30K72R 36K72R 36T72R36X72R 36U72R

42T72R42X72R

Standard Low Ambient Standard Low Ambient Standard Low Ambient Standard Low Ambient Standard Low Ambient Standard Low Ambient Standard Low Ambient

CH3672R

CH3672R

for KH3672R,TH3672R,XH3672R,UH3672R

CH2672R

forKH2672R,TH2672R,XH2672R,UH2672R

C2672R

C2462RCL2462R

for KS2462R

XH2672R

C1271 CL1271

KH3672RKH3072RKH2672R

CH4272R

Page 3: SANYO HVAC_Catalog - ACHR News - Air Conditioning, · PDF file2 Single split over 26000Btu (except 24KS62R) that operates in the A/C mode down to 0°F ambient temperature. SANYO Air

SANYO Line-Upp2•3

Feature Chart p4 • 5

Features– Features

p5 –7

Wall A/C– 09KS71/09KLS71– 12KS71/12KLS71/– 18KS72/18KLS72– 24KS72/24KLS72– 24KS62R/24KLS62R– 26KS72R– 30KS72R– 36KS72R/36KLS72

p8 • 9

Wall H/P– 09KHS71– 12KHS71– 18KHS72– 24KHS72– 26KHH72R/ 26KH72R– 30KH72R– 36KH72R p10 • 11

Flexi Multi– 19000 Btu– 24000 Btu– 31000 Btu

p12 ~15

Ceiling Recessed – 26XS72R– 36XS72R– 42XS72R– 26XH72R– 36XH72R– 42XH72R

p18 • 19

Concealed Duct – UH2672R– UH3672R p20• 21

Packaged Terminal– STW-2 Series

p22

26" Thru The Wall– STB-1 Series

p23

Portable – P0811 p24

Eco Multi – CHY7243 p24

Accessory p24 •25

Tube Length & Size,Operating Range

p26 •27

CONTENTS

3

18 K H S 7 2Voltage: 1:115V 2: 208/230VCooling Capacity in BTU/h

M: Muliti-Zone

Model Series No.

Wireless remote Control

Function H: Heat Pump L: Low Ambient

Indoor Unit Type K: Wall Mounted T: Ceiling Suspended X: 4way Ceiling Recessed U: Conceiled Duct

K H S18 7 2Voltage: 1: 115V 2: 208/230V

M: Muliti-Zone

Model Series No.Cooling Capacity in BTU/h

FunctionH: Heat Pump

Indoor Unit Type K: Wall Mounted T: Ceiling Suspended X: 4way Ceiling Recessed U: Conceiled Duct C: Outdoor unit

S: Wireless remote ControlH: Heater

Model Identification

System

Flexi Multi Inverter

Component 18KHS72Master model No.

(System)

CH1872Outdoor unit

KHS1872Indoor unit

+

2.55kW STW0622C2P STW0922C2P STW1222C2P3.45kW STW0623C2P STW0923C2P STW1223C2P STW1523C2P5.00kW STW0925C2P STW1225C2P STW1525C2P3.00kW STW0633C2 STW0933C2 STW1233C24.00kW STW0634C2 STW0934C2 STW1234C2 STW1534C25.00kW STW0935C2 STW1235C2 STW1535C22.55kW STW0622H2P STW0922H2P STW1222H2P3.45kW STW0623H2P STW0923H2P STW1223H2P STW1523H2P5.00kW STW0925H2P STW1225H2P STW1525H2P3.00kW STW0633H2 STW0933H2 STW1233H24.00kW STW0634H2 STW0934H2 STW1234H2 STW1534H25.00kW STW0935H2 STW1235H2 STW1535H2

Heater 7000 9000 12000 15000V

230/

208V

COOL

W/ H

EATE

RHE

AT P

UMP

W/ H

EATE

R

265V

230/

208V

265V

COOLING ONLY 115V STB0810C1P STB1010C1P230/208 STB1020C1P STB1220C1P

COOLING W/HEATER 115V STB0811C1P230/208 STB1023C1P STB1123C1P

HEAT PUMP W/HEATER 230/208 STB0823H1P

8000 10000 12000V

STW-2 Series STB-1 Series

Ceiling Suspended– 26TS72R

– 26TH72R– 36TS72R– 42TS72R– 36TH72R– 42TH72R– 26THH72R– 36THH72R p16• 17

Standard Low Ambient Standard Low Ambient Standard Low Ambient Standard Low Ambient Standard Low Ambient

WallMounted

KMS0772 KMS0972 KMS1272 KMS1872 KMS2472

Btu/h 7,000 9,000 12,000 18,000 24,000

WallMounted

Standard Low Ambient

Outdoor

Standard Low Ambient Standard Low Ambient

CM1972 CLM1972 CM2472 CLM2472 CM3172 CLM3172

Btu/h 19,000 24,000 31,000

Outdoor

CMH1972 CMH2472 CMH3172

KMHS0772 KMHS0972 KMHS1272 KMHS1872 KMHS2472

NOTE: All 7 series are R410A models

TypeBtu/h 19,000 24,000 31,000

AIR

CO

ND

ITIO

NER

TypeBtu/h 7,000 9,000 12,000 18,000 24,000

HEA

T PU

MP

Up to 3Rooms

Up to 4Rooms

Up to 4Rooms

Up to 3Rooms

Up to 4Rooms

Up to 4Rooms

Page 4: SANYO HVAC_Catalog - ACHR News - Air Conditioning, · PDF file2 Single split over 26000Btu (except 24KS62R) that operates in the A/C mode down to 0°F ambient temperature. SANYO Air

4

CeilingSuspended

MODEL FEATURE CHART OP: Option

OP

OP

OP

OP

●● ● ● ● ● ● ● ●

●●

- ● ●

- - -- - -- - -● ● ●

● ● ●

- - OP

- OP

- - OP

● ● OP

● ● - - - -● ● ●

● ● ●

● ● ●

● ● ●

● - ●

OP OP OP

● --●

--

--

--

--

- -- -

26U72R36U72R

● ●

● ●

● ●

● ●

● - ● - - -- - - -

OP OP

OP OP

- - OP OP

OP OP

● - OP OP

● ●

OP - ● ●

● ●

● ●

09KS7112KS7118KS7224KS72

● ●● ● ● ● ●

09KLS7112KLS7118KLS7224KLS72

24KLS62R 26K72R 30K72R36K72R

26T72R36T72R42T72R

26X72R36X72R42X72R

● ●

● ●

-- -

OP

OPOPOP

ODP=0Refrigerant

ElectricExpansion Valve

Low AmbientOperation

Built-In DrainPump

Duct Extension

Fresh Air Intake

Automatic RestartFunction afterPower Failure

Filter Sign

Anti-Mold Filter

SystemController

Weekly Timer

1-Hour OFFTimer

72-HourON/OFF Timer

24-Hour Clockwith ON/OFF

Program Timer

Hot StartHeatingSystem

Night SetbackMode for Cooling

and Heating

Automatic Heatingand CoolingChangeover

Louver Control

Air SweepControl

3 Fan Speedsand AutomaticFan Operation

Dry Mode

Self-DiagnosingFunction

Wired RemoteControl

WirelessRemote Control

Microprocessor-ControlledOperation

Negative IonGenerator

Apatite Filter

Concealed Duct

CeilingRecessed

Wall Mounted

----●

-●

--●

-●

-●

-●

-●

● ●

-

-

-

-●

-●

-

-●

--●

-●

---●

-

-

-

OP

● ●

---●

OP

OP

- OP

OP

-

-●

OP

OP

● ●

OP

OP

-

-OP

OP

- OP

OP

--

AIR CONDITIONERS LOW-AMBIENT AIR CONDITIONERS

--●

-●

--●

-●

----●

● ● ● ● ● ●

OP OP OP OP OP OP

OP OP OP OP OP OP

● ● ● ● - -● ● ● ● ● ●

● ● ● ● ● ●

● ● ● - ● ●

● ● ● - ● ●

● ● ● ● ● ●

- - - - - - ● ● ● ● ● ●

OP OP OP OP OP OP

OP OP OP OP OP OP

- - - - - -OP OP OP OP OP OP

OP OP OP OP OP OP

● ● ● - ● ●

OP OP OP - OP OP

● ● ● ● ● ●

- OP OP - - OP

- - ● ● - -- - ● ● - -● ● ● ● ● ●

● ● ● ● ● ●

● ● ● ● ● ●

09KHS7112KHS7118KHS7224KHS72

26KH72R30KH72R36KH72R

26TH72R36TH72R42TH42R

26XH72R36XH72R42XH72R

26UH72R36UH72R

26KHH72R

26THH72R36THH72R

HEAT PUMPS W/O HEATER HEAT PUMPS W/ HEATER

24KS62R

Page 5: SANYO HVAC_Catalog - ACHR News - Air Conditioning, · PDF file2 Single split over 26000Btu (except 24KS62R) that operates in the A/C mode down to 0°F ambient temperature. SANYO Air

5

Energy-Saving Operation The DC Inverter Air Conditioner affords continuous operation,while it adjusts capacity according to the room temperature.The accurate sensing of cooling or heating loads preventsfrequent changes in capacity and ensures efficient,economical operation.

DC INVERTER is outstanding for it‘s RAPID COOLING & HEATING POWER.As soon as the temperature is reached, it automatically adjusts current frequencytemperature fluctuation. It also provides “ENERGY-SAVING” (which saves your electricity charges) as well as “QUIETER OPERATION”.

Quiet Operation The DC Inverter Air Conditioner uses a twin rotarycompressor. Compared to the conventional single cylindertype, the twin rotary compressor dramatically reduces vibrationand noise during operation, thus ensuring quiet operation.

High SEER With the integration of inverter technology and R-410Arefrigerant, our products meet the DOE of a minimumrequirement of 13 SEER.

ODP (Ozone Depletion Potential) = 0 of HFC refrigerant is used.

High Power Mode The unit operates at maximum capacity by pressing a HighPower Mode button.

Rapid Cooling and Heating Since the DC Inverter Air Conditioner has efficient rapidheating and cooling capacity produced by variablecompressor rotation speed, it ensures quicker control ofroom temperatures than conventional air conditioners.

Features

Sanyo’s Ductless Split Air Conditioner & Heat Pump products offer wide versatility in solving your cooling andheating requirements. The Indoor unit (evaporator) is mounted inside the room, enclosed in a handsome spacesaving cabinet. It is connected to the outdoor unit (condenser) via refrigerant lines & inter-unit wiring througha 3-1/2" opening in the wall. Since no ductwork is required, installation is simple, fast & efficient. There is noneed to use up window space or cut large openings in existing walls, which could undermine the integrity ofyour structure, and even pose security risks. Since the Rotary compressor is located in the outdoor unit,compressor operating noise is virtually eliminated from the indoor. The indoor unit has been uniquelydesigned to provide Whisper Quiet operation while delivering comfort throughout the room (s). In addition, rotary compressors provide efficient, powerful cooling at the lowest noise levels in the industry.

SANYO: Your Best Choice in Ductless Split Air Conditioning Systems

Cooling Mode

DC Inverter air conditioner

Room Temp.

Desiredtemperature

Time until desired temperatureis reached Time

0˚C

Conventional air conditioner

Heating Mode

Room Temp.

Desiredtemperature

Time until desired temperatureis reached Time

0˚C

DC Inverter air conditioner

Conventional air conditioner

High Power

Maximum Hz

CompressorDriving Hz

Time

30 minutes

All Sanyo units are conduitconnectable for more safety.

Page 6: SANYO HVAC_Catalog - ACHR News - Air Conditioning, · PDF file2 Single split over 26000Btu (except 24KS62R) that operates in the A/C mode down to 0°F ambient temperature. SANYO Air

6

Microprocessor-Controlled Operation

Microprocessor control ensures that thetemperature and humidity levels in the room arealways comfortable.

Wireless Remote ControlSanyo’s infrared Remote Control withand easy to read LCD Display, gives the

user the capability to adjust & set: temperature,sweep (louver control), fan speeds, timer, nightsetback and more, for complete automaticoperation.

Dry ModeBy coupling compressor and fanoperation, intermittent operation can be

precisely controlled according to roomtemperature, so that air is efficiently dehumidified.

3 Fan Speeds and AutomaticFan Operation

Convenient microprocessor control automaticallyadjusts fan speed to High, Medium or Low.According to room temperature to maintain acomfortable airflow throughout the room.

Air Sweep Control The air sweep function moves the louverup and down in the air outlet, directing air

in a “sweeping” motion around the room andproviding comfort in every corner.

Louver ControlLouver can be manually set to thedesired angle by remote control.

Negative Ions Generator The abundance of negative ions is foundnear waterfalls and forests. The negative

ions generator fills your room with negative ionsthroughout the year. *Ion generating power - over 100,000 parts/cc

Automatic Heating andCooling Changeover

After setting the temperature and functions youdesire, just relax. If the room temperature ishigher than the set temperature, cooling operationbegins. If the room temperature is lower than theset temperature, heating operation begins. Duringnormal thermostat cycle operation, cooling andheating operations automatically change inaccordance with set temperature, time and roomtemperature. (Heat Pump unit only)

1-hour OFF TimerWhen this button is pushed eitherwhile the unit is operating or while it

is stopped, the unit will operate for one hour andthen switch off automatically.

12-hour ON/OFF TimerThis timer can be set to automaticallyturn the unit on or off at any time within

a 12-hour period.

24-hour Clock with ON/OFFProgram Timer

The remote control unit allows you to set a widevariety of timer-based operations. Suchfunctions include automatic ON/OFF with a timersetting, same time ON/OFF every day, ON timer,OFF timer and Combination timer.

ON/OFF TimerRemote controller

ON/OFF timer can be set to 0.5 hour gradations(max. 72 hours).

Night Setback Mode forCooling and Heating

Cooling and DRY Mode: With the Night SetbackMode, the air conditioner automatically raisesthe setting temperature 2°F after 30 minutes, andthen another 2°F after the next 30 minutes.Heating Mode: With the Night Setback Mode,the setting temperature is automatically lowered4°F after 30 minutes, and then another 4°F afterthe next 30 minutes. This saves energy withoutsacrificing comfort and is ideal for gentle coolingand heating.

Automatic Restart Functionafter Power Failure

This feature allows the system to automaticallyresume operation at its preset program, afterpower is restored from a power failure.

Hot Start Heating SystemRight from the start, air is warm andcomfortable. The Hot Start Heating

System prevents any cold blasts at the beginningwhile the heat pump is warming up. (Heat pump unit only)

Air Clean Apatite FilterApatite or calcium phosphate is highlyeffective in trapping germs, mites and

mite excrement, pollen, dirt and dust, andcigarette odor. The triple layered air cleanapatite filter consists of antibacterial,deodorizing, and dust-collecting sections thatmaintain healthy, clean air in your room.

Anti-Mold FilterFilter is treated with anti-mold

chemicals to prevent mold or bacteria fromoccurring.

Built-In Drain PumpMax. head 30 inches† from the bottom of

the unit. (condensate pump is only for allowingdrain line to meet minimum gravity flowrequirements.)

Features

Flap

Cool/Dry Mode

Heat Mode

Settingtemperature

Settingtemperature

Press theNIGHT SETBACK button

Press theNIGHT SETBACK button

30 min. 30 min.Time

30 min. 30 min.Time

2˚F

2˚F

4˚F

4˚F

In Cooling and DRY Mode

In Heating Mode

AdditionalFeatures

Filter SignFilter sign informs you when filtermaintenance is necessary.

2,500 hrs: X, T-types 150 hrs: K-type

Self-Diagnosing FunctionDetails of previous warnings arestored and can be verified on the

liquid crystal display. This makes it easier todiagnose malfunctions, greatly reducing servicelabor. (Wired remote controller)

(RCS-TM80BG)

(RCS-TM80BG)

Electric Refrigerant ControlValve

The circulation volume of the refrigerant iscontrolled by a pulse type electric control valve. Inorder to attain optimum efficiency, when thepower is switched ON, the opening degree of theelectric control valve is controlled between 90 and480 steps. (Ceiling Recessed Models only.)

Page 7: SANYO HVAC_Catalog - ACHR News - Air Conditioning, · PDF file2 Single split over 26000Btu (except 24KS62R) that operates in the A/C mode down to 0°F ambient temperature. SANYO Air

7

Wired Remote Controllers (Optional) over 26000 Btu, Except 24KS62R / 24KLS62R

Wireless Remote Controllers (Optional) over 26000 Btu, Except 24KS62R / 24KLS62R

Remote Controllers Functions

Timer Remote Controller(RCS-TM80BG)

Basic remote controller ON/OFF• Operation mode changeover (Cooling, Heating,

Dry, Auto, Fan.)• Temperature setting (Cooling/Dry: 64˚F-86˚F

Heating: 61˚F-86˚F.)• Air volume adjustment (HH, H, LL, Auto.)• Air flow direction adjustment.Time Function• 24 hours real time clock.• Day of the week indicator.

Weekly Program Function• A maximum of 6 actions can be programmed for each day.Unoccupied Function• Allows the temperature of the conditioned space to be preset to a desired

temperature, which will be maintained until manually changed. This feature isinitiated by pressing the symbol then setting the temperature by using the upor down arrows on the control. This provides a method of maintaining roomtemperature while at work or away on vacation, etc.

Sleeping Function• This function controls the room temperature for comfortable sleeping. Max. 8 indoor units can be controlled from one remote controller.Remote control by main remote controller and sub controller is possible.• Max. 2 remote controller (main remote controller and sub controller) can be

installed for one indoor unit.

System Controller(SHA-KC64UG)

• Used in combination with remote controllers, the systemcontroller can control up to 64 groups of indoor units (max. 64indoor units).

• Separating the 64 indoor units into 4 zones, each zone can becontrolled individually.

• Up to 16 groups (indoor units) can be registered to each zone.• Collective control and individual group (unit) control can also

be performed.• System without remote controller is also available.• Up to 2 system controllers (1 main, 1 sub) can be installed in a

system.• Alarm and operation outputs for an external collected signal

are available (potential free contact).

Applicable Unit For All Indoor UnitsWireless Remote Controller

RCS-SH80UA.WLRCS-SH1UA RCS-BH80UA.WL

BUILT-IN TYPE• Signal receiving unit can be installed in

the outer panel of indoor unit.• Control panel can be installed in the

inside indoor unit.

NOTE:If you use both remote controller and systemcontroller concurrently, both controllers can beused on a last-signal priority basis.

●: Controllable✕: Uncontrollable

EXTERNAL TYPE• Separate type signal receiving unit.

X-series

T-series U-series X-series T-series

(Ceiling Recessed Type)

(Ceiling Suspended Type)

Timer Remote Controller System Controller(RCS-TM80BG) (SHA-KC64UG)

Function

System

Setting Range

Operation mode switch

Auto flap

ON/OFFHeatingDryCoolingFan

Temp settingFan speed setting (Hi/Mid./Lo/Auto)

Auto airflow direction settingArbitrary airflow direction setting

Sweep (Flap swing)Sensor temp. displaySelf-diagnostic functionCentral control (at hand inhibited)Group controlConcurrent use with weekly timerCooling, dry (˚F)Heating (˚F)

● ● (Collective/Individual)● ● (Individual)● ● (Individual)● ● (Individual)● ● (Individual)● ● (Individual)● ● (Individual)● ●

● ●*● ●*● ✕

● ●

✕ ●

● (Up to 8 units) ● (Up to 16 groups)● ●

65 – 8661 – 79

Additional Features

K-series

Page 8: SANYO HVAC_Catalog - ACHR News - Air Conditioning, · PDF file2 Single split over 26000Btu (except 24KS62R) that operates in the A/C mode down to 0°F ambient temperature. SANYO Air

Model No.Power SourceCapacity Cooling Btu/hUnit Dimensions (HxWxD) inchNet Weight Lbs

Air Circulation (H/L)Cooling m3/hHeating m3/h

Operating Sound (H/L)Cooling dB-AHeating dB-A

Refrigerant Narrow Tube inchTube Diameter Wide Tube inch

Cooling OnlyKMS0772

7,500

19.8--

33 / 23-

1/4"3/8"

KMS0972

9,000

19.8--

34 / 23

1/4"3/8"

KMS1272

11,900

19.8--

36 / 25

1/4"3/8"

KMS1872

17,500

26.5--

41 / 28

1/4"1/2"

KMS2472

24,200

26.5--

44 / 30

1/4"5/8"

12

INVERTER Multi-System “Flexi-Multi”Fits with Various Sizes of Room and Life Style The multi-system type allows a single outdoor unit to be connected to 2 to 4 indoor units. It also solves the problem of limitedinstallation space and does not clutter the exterior of your home.

Indoor Unit: Wall Mounted Type

Model No.Power Source

CapacityCooling Btu/hHeating Btu/h

Unit Dimensions (HxWxD) inchNet Weight LbsAir Circulation (H/L) Cooling m3/h

Operating Sound (H/L)Cooling dB-AHeating dB-A

Refrigerant Narrow Tube inchTube Diameter Wide Tube inch

Heat PumpKMHS0772

7,5008,500

19.8-

33 / 2333 / 23

1/4"3/8"

KMHS0972

9,00012,200

19.8-

34 / 2334 / 23

1/4"3/8"

KMHS1272

11,90014,300

19.8-

36 / 2534 / 25

1/4"3/8"

KMHS1872

17,50020,400

26.5-

41 / 2840 / 28

1/4"1/2"

KMHS2472

24,20029,000

26.5-

44 / 3043 / 30

1/4"5/8"

230V-60Hz

230V-60Hz

KMS0772 / KMS0972 / KMS1272

KMHS0772 / KMHS0972 / KMHS1272

KMS1872 / KMS2472

11"-7/32" x 32"-15/32" x 7"-7/16" 11"-23/32" x 41"-15/16" x 8"-19/32"

11"-7/32" x 32"-15/32" x 7"-7/16" 11"-23/32" x 41"-15/16" x 8"-19/32"

Only for CLM1972, CLM2472,CLM3172

KMHS1872 / KMHS2472

Page 9: SANYO HVAC_Catalog - ACHR News - Air Conditioning, · PDF file2 Single split over 26000Btu (except 24KS62R) that operates in the A/C mode down to 0°F ambient temperature. SANYO Air

Performance Capacity Btu/hAir Flow High CFMNumber of Connectable Indoor UnitsSEER CoolingHSPF Heating

Electrical RatingPower Supply V, Phase, HzRunning Ampere APower Input W

FeaturesControlsFan SpeedsCompressorRefrigerant / Amount Charged at Shipment gRefrigerant ControlOperation Sound Hi dB-ARefrigerant Tubing ConnectionsMax. Allowable Tubing Length per Unit FtRefrigerant Narrow Tube inchTube Diameter Wide Tube inchDimensions & WeightUnit Dimensions H x W x D inchNet Weight Lbs

Model No. Oudoor Unit CM1972 / CLM1972 CMH1972

13

DC Inverter Multi-System Outdoor Unit

It is not possible to connect an outdoor unit to only a single indoor unit. If operated with only ONE indoor unit installed, the returning refrigerant to the compressor may cause a malfunction.

Cooling

19,7001,7002 ~ 3

13-

230V / 208V, 1Ph, 60Hz6.52 / 7.19

1,465 / 1,465

MicroprocessorAuto (Hi, Me, Lo)

DC InverterR410A / -

Electric Expansion Valve50

Flare Type150

1/4" x 3"3/8" x 2" / 1/2" x 1"

29"-1/8" x 35"-1/2" x 12"-5/8"138

Cooling Heating

19,100 24,8001,700

2 ~ 3137.7

230V / 208V, 1Ph, 60Hz6.20 / 6.86 7.25 / 8.00

13.95 / 13.95 16.30 / 16.30

MicroprocessorAuto (Hi, Me, Lo)

DC InverterR410A /-

Electric Expansion Valve50 52

Flare Type150

1/4" x 3"3/8" x 2" / 1/2" x 1"

29"-1/8" x 35"-1/2" x 12"-5/8"143

IMPORTANT

Up to 3Rooms

Connectable from 2 to 3 Indoor Units

CM1972 / CLM1972 CMH1972

Page 10: SANYO HVAC_Catalog - ACHR News - Air Conditioning, · PDF file2 Single split over 26000Btu (except 24KS62R) that operates in the A/C mode down to 0°F ambient temperature. SANYO Air

DC Inverter Multi-System Outdoor Unit

Performance Capacity Btu/hAir Flow High CFMNumber of Connectable Indoor UnitsSEER CoolingHSPF Heating

Electrical RatingPower Supply V, Phase, HzRunning Ampere APower Input W

FeaturesControlsFan SpeedsCompressorRefrigerant/Amount Charged at Shipment gRefrigerant ControlOperation Sound Hi dB-ARefrigerant Tubing ConnectionsMax. Allowable Tubing Length per Unit FtRefrigerant Narrow Tube inchTube Diameter Wide Tube inchDimensions & WeightUnit Dimensions H x W x D inchNet Weight Lbs

Model No. Oudoor Unit CM2472 / CLM2472 CMH2472

It is not possible to connect an outdoor unit to only a single indoor unit. If operated with only ONE indoor unit installed, the returning refrigerant to the compressor may cause a malfunction.

Cooling

25,4001,7002 ~ 4

13-

230V / 208V, 1Ph, 60Hz10.91 / 12.052,455 / 2,455

MicroprocessorAuto (Hi, Me, Lo)

DC InverterR410A/-

Electric Expansion Valve50

Flare Type200

1/4" x 4"3/8" x 2" / 1/2" x 1" / 5/8" x 1"

29"-1/8" x 35"-1/2" x 12"-5/8"

Cooling Heating

23,200 29,2001,7002 ~ 4

137.7

230V / 208V, 1Ph, 60Hz8.60 / 9.50 9.62 / 10.63

1,935 / 1,935 2,165 / 2,165

MicroprocessorAuto (Hi, Me, Lo)

DC InverterR410A / -

Electric Expansion Valve50 52

Flare Type200

1/4" x 3"3/8" x 2" / 1/2" x 1" / 5/8" x 1"

29"-1/8" x 35"-1/2" x 12"-5/8"

IMPORTANT

14

Connectable from 2 to 4 Indoor Units

CM2472 / CLM2472 CMH2472

Up to 4Rooms

Page 11: SANYO HVAC_Catalog - ACHR News - Air Conditioning, · PDF file2 Single split over 26000Btu (except 24KS62R) that operates in the A/C mode down to 0°F ambient temperature. SANYO Air

It is not possible to connect an outdoor unit to only a single indoor unit. If operated with only ONE indoor unit installed, the returning refrigerant to the compressor may cause a malfunction.IMPORTANT

15

Performance Capacity Btu/hAir Circulation (High) High m3/hNumber of Connectable Indoor UnitsSEER CoolingHSPF Heating

Electrical RatingPower Supply V, Phase, HzRunning Ampere APower Input W

FeaturesControlsFan SpeedsCompressorRefrigerant/Amount Charged at Shipment gRefrigerant ControlOperation Sound Hi dB-ARefrigerant Tubing ConnectionsMax. Allowable Tubing Length per Unit FtRefrigerant Narrow Tube inchTube Diameter Wide Tube inchDimensions & WeightUnit Dimensions H x W x D inchNet Weight Lbs

Model No. Oudoor Unit CM3172 / CLM3172 CMH3172

Cooling

30,6001,9402 ~ 4

13-

230V / 208V, 1Ph, 60Hz11.70 / 12.902,660 / 2,660

MicroprocessorAuto (Hi, Me, Lo)

DC InverterR410A / -

Electric Expansion Valve53

Flare Type230

1/4" x 4"3/8" x 2" / 1/2" x 1" / 5/8" x 1"

35"-1/32" x 35"-1/2" x 12"-5/8"

Cooling Heating

30,600 32,000

2 ~ 4137.7

230V / 208V, 1Ph, 60Hz11.70 / 12.90 9.70 / 10.702,660 / 2,660 2,210 / 2,210

MicroprocessorAuto (Hi, Me, Lo)

DC InverterR410A / -

Electric Expansion Valve53 52

Flare Type230

1/4" x 3"3/8" x 2" / 1/2" x 1" / 5/8" x 1"

35"-1/32" x 35"-1/2" x 12"-5/8"

Connectable from 2 to 4 Indoor Units

CM3172 / CLM3172 CMH3172

Up to 4Rooms

Page 12: SANYO HVAC_Catalog - ACHR News - Air Conditioning, · PDF file2 Single split over 26000Btu (except 24KS62R) that operates in the A/C mode down to 0°F ambient temperature. SANYO Air

Because its products are subject to continuous improvements, Sanyo reserves the right to modifyproduct design and specifications without notice and without incurring any obligations. ©Copyright 2006, SANYO Air Conditioning Products.

SANYO Fisher CompanyA Division of SANYO North America Corporation

21605 Plummer Street, Chatsworth, CA 91311, USAPhone: 818-998-7322 Fax: 818-701-4170website: http://www.sanyohvac.com