Page 1: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

SANITARY WATER WALL MOUNTED

Operation & Installation Manual

Page 2: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

If the earth wire connection is in poor condition or there is no earth wire in your

house, please don't use the units.

If you can not be sure that the earth wire is in good condition, please ask the

qualified personnel to check it.

Safety is the most important!

Keep this manual by the system and carefully read the operating instructions

before commissioning the system. There are markings for all safety warnings. The

meanings are as follows:

There will be potential danger for you and others.

Wrong operations may lead to the life risk or serious injure.

Wrong operations will lead to the life risk or serious injure.

This kind of units is the type electrical equipment

Ensure perfect earth wire connection before use.

WARNING

ATTENTION

WARNING

DANGER

Page 3: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

CONTENTS 1. Safety Precaution 1

2.Installation Position 2

3.Safety Points For Attention 3

4.Specifiction 6

1 Appearance 6

2 Feature 6

3 Principle 7

4 Structure & Dimension 8

5 Performance parameter 9

5.Function 10

6.Installation 11

1 Installation sketch map 11

2 Choose the suitable unit 12

3 Preservation and transportation 12

4 Choose the suitable installation position 13

5 Hydraulic connection 15

6 Electric wiring 17

7 Trial operation 17

7. Operation & Usage 18

1 Fuction sketch map for wire controller 18

2 Usage of wire controller 18

3 Parameter seting 20

4 Set point automatic regulation 21

5 Normal failure and solution 21

8.Maintenance & Repair 22

1 Maintenance 22

2) Use for overhea ting protector 22

3 The non-fault phenomena 23

Page 4: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

1. Safety Precaution

1

WARNING

ATTENTION

The earth electrode of socket should have the perfect earth wiring and the rating

current should be more than 16A. Keep the socket and plug dry to avoid leakage and check

if they are connected well usually. The check ways are as follow: Put the

plug into the socket and turn on the unit, then pull out the plug half an hour later and check if the plug is hot. If it is hot (more than 50 ℃), please have a qualified socket to replace it to avoid the burnout or fire caused by the bad connect.

Because the water in the tank is very hot (the water more than 50 ℃ will burn body), you should adjust a suitable water temperature before spraying to the body.

If the power cable is damaged, ask the professional serviceman to use the cable which

provided by the manufacturer to replace it.

If the parts are damaged, ask the professional serviceman to use the parts provided by the

manufacturer to replace it.

The heat pump must be installed by qualified personnel to avoid improper installation which

will lead to water leakage, electrical shock or fire.

The local assembly should be the ones designated by manufacturer. The

power lines connection should be complied with the local rules.

If you need to remove or reinstall the unit, please ask the qualified personnel to make it to

avoid improper installation which will lead to water leakage, electrical shock or

fire.

The heat pump should be maintained by qualified personnel to avoid improper

maintenance which will lead to water leakage, electrical shock or fire.

Good earth wire connection is necessary for household electricity.

Electric leakage protector is necessary for household electricity.

Don't rip off any explications, labels or parameter tables on/in the unit.

WARNING

Page 5: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

2

2. Installation position

Suitable installation position

1 The unit can be installed inside or outside of house. Installed in the basement is better.

2 Choose the place without direct sunlight or other radiant heat source . If it is possible,

a cover is necessary to avoid the direct sunlight.

3 No obstacle at the air inlet and outlet, the place without strong wind. 4 The place with enough space to install and maintain should be dry and drafty. 5 The bearing surface should be flat (inclination should be less than 2°) be able to bear

the unit and place the unit without noise and vibration added.

6 The place where the noise and air out will not affect the neighbour.

7 The place without the combustible gas.

8 The place where it is easy to install the pipe and electrical wiring.

9 If the unit is installed on the metal part of building, the electrical insulation which should

be according to the technic standard must be used.

Attention

It will lead to fault to install the unit at the places below (if it is inevitable, please contact us) The

place with mineral oil just like grass cutter oil.

The place with a lot of salinity in the air, for example near the sea..

The place with corrosive gas (sulphur gas etc.),for example the area of hot spring. The

place with the serious power fluctuations, for example near the factory.

In the car or cabin.

The place with oil gas, for example the kitchen. The

place with the strong electromagnetic wave. The

place with inflammable gas and material.

The place with acidity or alkalinity gas.

The others special palces

Page 6: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

3

3>Safty attention

To prevent users' personal property damage and operate the unit in the correct and safety way,

please carefully read the main contents in the manual. Based on completely

understanding the following contents(the signs and diagrams)then read the body text, comply with the

following notice.

1. The damage means no need of in hospital, long-term treatment, make a general reference to

injure, burn and electric shock.

2. Material damage means property and material loss.

Installation

warning

DO NOT

Under no circumstances should you put your fingers or

tools in to air-ducts of the unit. Operation

warning

Shut off

the power

When there is something wrong or strange smell, the

power supply should be shut off to stop the unit.

Continuing to run may cause electrical short of fire.

Safty attention

Marking The significance of the marking

The false operation may resulting in casualties..

Warning

The false operation of resulting in terrible injuries or property damage.

Attention

Icon The significance of the Icon

It means forbidding, the detail content are within the icon or expressed by graph

or words closed to the icon.

It means Enforcement. The detail content are within the icon or expressed by

graph or words closed to the icon.

It means attention including warning. The detail content are within the icon

or expressed by graph or words closed to the icon.

Warning

Professional installer

is required

The heat pump must be installed by qualified personnel to

avoid improper installation which can lead to water

leakage, electric shock or fire.

Earth wire is required

Please make sure that the unit and power connection have

good earthing, otherwise may cause electric shock.

Concentration

limits

When installing the unit in a small room, please take

measures to prevent the asphyxia caused by the leakage of

refrigerant.

Page 7: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

4

3. Safety attentions

Installation Attention Items

Confirm the

installation location

It could not be installed near the flammable gas which may

cause leakage. Once the flammable gas leaking around the unit,

it may cause fire.

Confirm the

fixed measure

Confirm the foundation is solid.

Confirm the

electrical protection switch

Verifying whether has installed the leakage protection switch.

If without installing electrical protection switch, it may cause

personnel electric shock or fire.

Move

and

repair

Operation

attention

Entrust

When the unit needs to be moved or re-installed, please engage a

qualified person to carry out the work. Improper installation

will lead to water leakage, electric shock, injury or fire.

Prohibit

The user must not repair the unit, otherwise the warranty will be

invalidated.

Entrust

When the unit needs to be repaired, please entrust qualified

person of the dealer to do it. Improper movement or repair of the

unit will lead to water leakage, electrical shock, injury or fire.

Warning

This equipment is applied to the professional and

experienced operators to use, kids and unhealthy persons be

cautious on this. Please read the manual carefully before

operating.

Check the

install placement

If the unit is not to be used for any long period and the ambient

temperature is below 0 degree, please drain the water in the

tank to prevent freezing and consequent damage.

Shut off

the power

When being cleaned, shut off the power to the unit , otherwise

injury could occur.

Prohibit

Please use a suitable fuse, otherwise it maybe cause failure and

fire.

Prohibit

Do not spray flammable towards or around the unit, otherwise it

could cause a fire.

Page 8: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

5

3. Safty attentions

Warning

Take a qualified professional person to be responsible for the installation work, if our own

hands, an incorrect installation may cause water leakage, and fire, etc.

Choose the location without direct sunlight and other heat source direct radiation. If you

can't avoid, please install a covering to prevent the sun blazed down the machine. Please install

the unit firmly, or it may cause noise and shock due to the poor installation.

Please move away the obstructions near the air inlet and outlet, to prevent the

performance become lower. When you installed beside the sea or somewhere with

strong wind, in order to ensure fans operating normally, please put the unit at the position

Page 9: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

4. Specification

6

1. Appearance

2. Features

Good looking and high efficiency

Unit via streamlined design and combined with the exterior decoration, looks more

exclusive. Unit with the characteristics of energy saving, the total energy consumption is only

65% of solar water heater and 25% electrical water heater.

Environmental protection and safety

Units via electricity driven compressor, heating up the sanitary water through the

refrigerant, without waste gas and waste water, green environmental protection, in this way avoid

the situation that water contacts with electricity directly, creating waste gas,

completely stopping electricity leakage and gas poisoning happening.

Simple operation and wide range of uses

The unit is not only with simple operation but also could set the water temperature

according to the ambient temperature; heating the water meanwhile recycling indoor waste heat.

Wind outlet

Wind inlet

Water tank

Wire controller

Page 10: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

4. Specification

7

3. Working principle

System diagram:

High temp.

System Principle:

Refrigerant is compressed into vapor with high temperature and high pressure when it goes

through the compressor.

On the discharge side of the compressor, the now hot and highly pressurized vapor is cooled

down through the heat exchange with the water in the tank until it condenses into a high

pressure, moderate temperature liquid.

Then the pressure of the liqiud refrigerant drops as it passes expansion valve.

Finally, refrigerant absorbs heat from the surrounding air and evaporates into vapor with low

temperature and low pressure and then it goes into compressor again.

The cooled surrounding air could be blew to the rooms which needs fresh cooled air.

Compprreessssoorr 1

Hot water

Air from outside

4

Air fin exchanger

5

Duct

Cold air Optional discharged air space needed

2 Tank

Water supply

Low temp. Liquid

3

Throttling device

1

2

3

4

5

Page 11: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

8

Air inlet

overheating protector

Supporting bracket

Pressure release valve

D

225

Supporting bracket

Hot water outlet 152 75

Cold water inlet

Condensing water drainage pipe

4>Specification

4. Structure and dimension

Unit mm

Model Dimension WSW1-80L-WM

A 1215

B 877

C 407

D 0520

E 288

0125 Air outlet

C

E

150

B

A

Page 12: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

4. Specification

9

5. Performance table

Model Wall Mounted

WSW1-80L-WM

Heating capacity kW 1.0

Water tank capacity L 80L

Power input kW 0.27

Running current A 1.2

Power supply

230V~/50H z

Compressor number

1

Compressor

Rotary

Rated outlet water temp. °C 55

Noise dB(A) 45

Water inlet/outlet size inch 1/2

Net dimensions mm see the drawing of the units

Shipping dimensions mm see package label

Net weight kg 69

Shipping weight kg 80

Measurement conditions:

Instant heating: Ambient temperature15°C/13°C,Water inlet 15°C ,Water outlet 45°C

Work range

(1).Ambient temperature is 0-43°C

(2).The range of the operating water temperatures:

10~60°C (3).The max temperature of water tank is 60°C

Operating parameters:

(1).The range of the operating water pressures: 0.1~0.7MPa

(2).The max temperature of water tank is: 0.6MPa

Page 13: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

10

5> Functions explanation

1.Machine function description

Because the supplied hot water absorbs heat from the surrounding air and release the heat at heat

exchanger side. Once ambient temperature goes down, the heating capacity may

decrease accordingly.

When stopping after running, the user immediately starts the unit or turns on manual switch, the unit

will not run within 3 minutes. This phenomenon is to protect compressor by the main controller.

In heating mode, if the unit freezes, the machine will automatically defrost to promote heating

capacity.(2 to 10 minutes). Under defrosting process, the fan motor of the unit will run and

compressor will stop working.

The unit only can use tap water .Please do not use the water from any lake, river or underground

water which are not filtrated or treated.

If power is cut during machine running, the unit will stop immediately. If the unit is mis-works

because of thunder, wireless of motor car, power net fluctuation, please turn off the power switch by

hand. After the unit restarts, the user can re-press the running/stop button.

The unit must be connected with power net through current leakage protector.

When water temperature reaches 75℃, the electric heater will be off(automatic recovery). When water temperature reaches 85℃, the fuse of electric heater will fuse (un-recovery)

In the water system will be installed the Pressure release valve. When the tank pressure reach

0.7MPa, the Pressure release valve to open sluice.

Concerning to power cut

Defrosting function in heating mode

Heating capacity

3 minutes protection

The running condition of water heater

Concerning current leakage protector

Concerning to electric heater protection

Concerning to pressure release protection

Page 14: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

6.Installation and connection

11

1. Hot water heat pump installation diagram

Air flow outlet

Air flow inlet

≥ 400mm ≥ 600mm

Pressure

overheating protector release valve

Hot water outlet

Condensing water

water in Filter drainage pipe

One way valve

Drainage water

The shortest distance allowed:

To not affect the air inlet and outlet of the machine, please confirm the installation distance as the

picture shows above.

Warning

Installing safety valve or Pressure release valve is a necessary. Do

not hold the handle of safety valve.

Do not discharge the safety valve orPressure release valve. Do

not jam drainage pipe.

Drainage pipe goes to a opening box or port.

These factors may lead to death or explosion if not complied to these

warnings.

Page 15: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

6. Installation and connection

12

2. Choosing a proper model

For energy-saving and convenience purpose, please choose proper volume of a water tank, the

selection case is below:

80-100L is proper for 1 - 3 users.

3. Storage and transportation

Generally, it's better to use a container to transport hot water heat pumps and store them in a

suitable and dry place. To short distance carrying, please be careful and the maximum

inclination is no more than 60°.During transportation and storage, the ambient temp is better from

0°C -43°C.

Transported by forklift

When using forklift to carry the unit which must have a pallet, the operator should try best to

keep the height of forklift at a lowest level. Because the top part is heavier ,the operator needs

to take measures to prevent its overturn. To avoid any damages, the unit must stand on a flat

place.

Transport for installation

When transporting for installation, the bottom of unit needs to be added with pallet and use

a rope or belt to fix it well. By this manual carrying or forklift transportation, the inclination is no

more than 60°as the following picture shows. If the inclination unavoidably exceeds 60°,the unit must be kept at vertical status for at least 1 hour and then can be started for testing or

running.

Notice: The selection of a water tank is only a reference, please choose a

proper. one according to local weather and users consuming habit.

Notice Prevent bottom up

Page 16: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

13

6.Installation and connection

4 Installation place choosing

(1) Wall-mounted installation and offering sanitary hot water See picture below

The unit is mounted on the wall which will not take up much space.

(1) Waste heat recycled application(See picture below)

The unit can be installed outside of kitchens, fire place rooms and garages where have much waste heats. This way can assure a high COP during low ambient temp in winter and realize energy-saving purpose;

Page 17: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

14

6.Installation and connection

3 Sanitary hot water and dehumidification (See picture below)

4 Sanitary hot water and cooling storage room (See picture below)

The unit can be put in storage room of wine, drink, fruits. When the unit is making hot water, it

also can provide cool air to fresh the foods. One machine can realize various functions and reach an

excellent effect.

Page 18: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

15

6. Installation and connection

1) Choose a right way of carrying the unit in.

2) Try best to carry the unit with original package.

3) If the unit is installed on the metal parts of a building, all parts need to be electric-

insulated well to fully meet related technical standards on equipments.

5. Hydraulic connection

Please notice the points below when connecting the water pipes: Try

best to decrease the resistance in water pipes.

Inner surface of whole pipe system should be clean, no rusty spots and dirts to avoid any pipe

jam. After connecting pipes, please check the leakage status of whole system to

assure there is no leakage firstly and then make the insulation.

Add one-way valve, Pressure release valve and other safety valve in water way.

The installation of water pipes have to be accordance with the requirements of the local

standard(To avoid too higher water pressure, please install a discharge valve ).

When connecting the water pipes, please prevent any pollution going into pipes.

The male specification of Pressure release valve is G3/4". After installation, please assure

that drainage pipe is open to the air.

If the discharge outlet of Pressure release valve is drainage hosepipe, please assure its

direction is down and its outlet is opened to the air. At the same time, the valve should be in a

no-frosting surroundings.

Attention items before installation

Attention

At least pull once half a year the handle of one way valve in order

to remove the sediment of Calcium Carbonate. Please confirm

the device is with no jam. The drainage outlet water temp is high,

please pay attention to it.

Please make good insulation to drainage pipe to prevent pipe

freezing in winter, which may lead to safe accidents.

The discharge mouth water temperature may be higher than e

xpected and please take care to avoid burns.

Handle

Drainage pipe

Page 19: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

16

6. Installation and connection

Installation instruction diagram

Accessories provided: safety release valve.

Attention

After installing the connecting pipe according to the diagram, open the water tap and the hot water

switch of the unit, make the water inject in the unit. Then there will be a large amount of air draining

off from the hot water switch(This process will lasts for 5-20minutes).When there is just water outflow

but no air outflow, it suggests that the unit is full of water, the air is

completely drained off.

Do not use stainless steel fittings to connect directly with other metals to prevent galvanic

corrosion.

The wall

Stop valve Heat pumpwater heater

Filter Cold water inlet pipe

Hot water outlet pipe

Pressure release valve drain pipe

The draining water pipe for condensate water

The location of draining water

On draining off the air from the tank

Page 20: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

17

6.Installation and connection

6. Electric wiring

Instruments should be installed in accordance with state wire installation rules.

At the bottom of the unit there are electric plugs for the user to connect the unit to the

power supply.

When the external circuits connecting with the unit, the circuit connection should be with

leakage protection device and power broker device.

If the power line is damaged, you must purchase a new one from the factory or a qualified

agent ,or other products with the same certificates.

7. Trial operation

1. The examine before trial operation

Check whether the water tank is full of water and the water pipes are installed well.

Examine the power supply distribution system and check whether the voltage is normal and

the earth wires and wiring connections are in good condition.

Examine the unit: When the unit is power on, observe whether the indicator light and the

temperature of the controller are working normally.

2. Test running

Starting the unit by the wire controller.

When the unit is operating, judge the unit whether is with abnormal sound by hearing, if so,

the unit should be stopped and examined at once.

Check the water temperature in the water tank to see whether it is normal.

It may need 5 ~ 15 hours for the unit to achieve the target temperature for the first time

depends on the water and ambient temperature.

Attention

Power lines shall be arranged in neat and reasonable way and in accordance with

state cord rules for installation.

Page 21: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

18

7.Operation and usage

M

1. controling panel function sketch map

Setting temperature

Standard mode indicator light(yellow)

Running indicator light(red)

Outlet water temperature

Energy saving mode indicator light(green)

Rapid heating mode indicator light(red)

M

Modes choosing button Decrease button

Power on/off button

2. The operation of the wire controller

1 Power on.

Increase button

When the unit is powered on, the unit would stay at pausing or operating, this condition

depends on the state of the unit last time on which when power off. When the unit stays at

pausing, the red light is off.

2 Viewing the modes Continuing pressing could choose the standard mode,energy saving mode or rapid heating mode.

Yellow light shining Red light shining

M

Standard mode

M

Energy saving mode

Green light shining Red light shining

Page 22: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

19

7.Operation and usage

Red shine Red shine

M

Rapid heating mode

The functions of three different modes are as following:

1 Standard mode When the yellow light of standard mode shining, it suggests the unit is

working in the standard mode condition. The mode is applicable to the climate conditions of

the whole year. It is the recommended mode.

2 Energy saving mode: When the green energy

saving light shining, it suggests that the unit is working in the energy saving mode, at this time

just the compressor is operating but the electric heater is not. In the case of not being eager for using

the hot water, choosing this mode may save the supply cost. It is suggested that this

mode be used when the ambient temperature is above 10℃ . 3 Rapid heating mode: When the yellow indicator light and the green indicator light shining

at the same time, this suggests that starting up the compressor meanwhile the electric heater is

power on. This mode is suitable for urgent hot water needs.The users could choose any

modes according to the actual demand, it is suggested to set the unit to standard mode.

Power on/Power off

It’s the power switch of the unit. When the unit is operating, the indicator light is shining.

Power off status

Green light shining

M

Press the on/off button

Power on mode

Green light shining Red light shining

M

Page 23: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

20

M

UP DOWN

press " " to rise the set point

Press " " to decrease the set point

7. Operation and usage

3. Parameter setting

Power on and press " to rise the set point, press " to decrease the set point.

Set point Water out temp.

Page 24: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

21

7.Operation & Usage

4. Set point automatic regulation

The mode of the factory setting is automatic mode, which it can change the set point follow the

ambient temperature automatically. Decreasing the set point properly can save more

energy in the summer and the set point will rise automatically to make sure the comfortable use in

the winter. Of course, you can set the point by manual. Use up or down arrow key set

the hot water temperature. The unit will disable automatic function, after the manual setting. You can

press the mode key for 10 seconds to recover this function.

5. Normal failure and solution

Troubleshooting:

Fault Code display Reason Solution

Turn on

Running

Bottom sensor failure P 01 The sensor is open or short circuit Check and replace the bottom temp.sensor

Upper sensor failure P 02 The sensor is open or short circuit Check and replace the upper temp.sensor

Coil sensor failure P 03 The sensor is open or short circuit Check and replace the coil temp.sensor

Suction sensor failure P 04 The sensor is open or short circuit

Check and replace the suction temp.sensor

Ambient sensor failure P 05 The sensor is open or short circuit Check and replace the ambient temp.sensor

High pressure protection E 01 The high pressure is over 21bar or pressure switch connection open.

Check connection and refrigerant system.

Low pressure protection E 02 The low pressure switch connection open.

Check connection and refrigerant system.

Thermal protection E 03

Water temperature is too higher, more than 85℃。

Check if the water is enough

Communication failure

E 08

Communication cable disconnect or have a strong interference near the unit.

Check the connection of the pcb.

Defrosting Flash

Page 25: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

22

8.Maintenance & Repair

1. Maintenance.

Check the parts of the unit and the pressure of the system regularly (1 year). If there is any

unusual phenomena, repair and replace it immediately.

Check if the electrical wiring is firm and the electrical element has any unusual action and smell.

If so, repair and replace it immediately.

Do not power off the unit if the unit is not used for a long time. We will not be responsible for any

broken caused by the frost crack of parts due to the long time power off.

Check if the power socket and plug have a good contacting, perfect earth and any thermal

protection.

In the cold area (below 0 ℃), if you do not use the unit for a long time, please drain the water of the tank to avoid the damage due to freeze. In order to ensure the long efficient work of the

unit, please clean away the precipitate in the tank every half year. Please do it as follow: 1.Turn

off the power supply.

2. Turn off the water in valve and turn on the hot water tap. Turn off the hot water tap after

draining the sewage from the hot water tap.

3. Take apart the tap water pipe from the safety relief valve, put the drainpipe into the

draining hole out let of room.

4. Turn on the hot water tap drain off all the water in the tank. Use water clean several times if

need.

5. Connect the tap water pipe to the unit again and inject the water into the tank. Turn on the

power supply. If the hot water is enough to use, you can decrease the set point to reduce the

heat dissipation, which can save more energy and extend the life of the unit.

2. Use for overheating protector

Overheating protector is used to prevent safety accident caused by water temperature inside the

tank too high in case that the heat pump controller is out of control. When the temperature inside the

tank reaches the action value of the protector, the power supply will be cut off. It has to be reset

manually so that the unit returns to normal. The operation in detail is as following:

Be careful electric shock when you press red button.

Warning

loosen the screws and open the cover Press the red button to reset

Protection cover of the protector

Page 26: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

23

8. Maintenance & Repair

3. The non-fault phenomena

1 Why the compressor is not running when I start the unit?

Answer When the unit is on after stopping, the unit will not run until 3 minutes later. It is the

self-protection of unit. When the ambient temperature is lower than 2°C, the compressor will stop and

the electric heater will be on.

2 Why the unit does not stop when the water outlet temperature on the display reaches the

set point

Answer Because there are two sensors, upper sensor and bottom sensor, in the unit. The water

outlet temperature on the display is only from the upper sensor. The bottom water

temperature in the tank will decrease when you use some water, although the upper water in the

tank has the set point temperature. The unit will not produce heat until the bottom sensor senses

the set point.

3 Why the water outlet temperature on the display creases slowly?

Answer Because the water temperature is different between the upper layer and under layer

in the tank at the beginning. When whole the water in the tank have the same temperature, it

will rise faster.

4 Why the water outlet temperature on the display decreases when the unit is heating

Answer If the upper water temperature is much higher than that of the bottom water, then the water

temperature will decrease a little because of the convection between hot water and cold water in the

tank.

5 Why the unit does not start up to heat when the water outlet temperature decreases

Answer: The water temperature will decrease because of the heat loss if the hot water in the tank is

not used for a long time. In order to avoid the continual ON/OFF, the unit does not start up until the

water temperature decrease more than 5°C.

6 Why the water temperature decrease a lot abruptly?

Answer: The temperatures of hot water and cold water in the tank are different. The cold water may

go to the upper sensor when the hot water have been used up.

7 Why the hot water is still available when the water out temperature on the display

decreases

a lot

Answer: Because the upper sensor is positioned near the top of the tank, there is still 1/5 of hot

water available when the water outlet temperature on the display decreases a lot.

8 Why the compressor stops but the fan keeps running when the unit is in the heating mode?

Answer: The unit needs to defrost when the evaporator freezes because of the low ambient

temperature. The compressor will stop and the fan keeps running when the unit defrosts.

9 Why the heating time is so long, more than 10 hours?

Answer: Energy saving, small power and long heating time are the distinguishing features of the

units. Normally, the heating time is 4~15 hours due to the water inlet temperature, water

consumption and ambient temperature.

Page 27: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor
Page 28: SANITARY WATER - Winston · WSW1 -80L WM Heating capacity kW 1.0 Water tank capacity L 80L Power input kW 0.27 Running current A 1.2 Power supply 230V~/50H z Compressor number 1 Compressor

CODE 20170424-0001