san diego district office 7575 metropolitan drive, suite 103 san diego… · 2020. 8. 21. · san...

4
STATE OF CALIFORNIA - NATURAL RESOURCES AGENCY GAVIN NEWSOM, GOVERNOR CALIFORNIA COASTAL COMMISSION SAN DIEGO DISTRICT OFFICE 7575 METROPOLITAN DRIVE, SUITE 103 SAN DIEGO, CA 92108-4402 VOICE (619) 767-2370 FAX (619) 767-2384 Th5a 6-19-1013 (Caulfield et al. Revetment) September 10, 2020 EXHIBITS EXHIBIT 1: Project Location EHXIBIT 2: Site Plans

Upload: others

Post on 10-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SAN DIEGO DISTRICT OFFICE 7575 METROPOLITAN DRIVE, SUITE 103 SAN DIEGO… · 2020. 8. 21. · SAN DIEGO DISTRICT OFFICE 7575 METROPOLITAN DRIVE, SUITE 103 SAN DIEGO, CA 92108-4402

STATE OF CALIFORNIA - NATURAL RESOURCES AGENCY GAVIN NEWSOM, GOVERNOR

CALIFORNIA COASTAL COMMISSION SAN DIEGO DISTRICT OFFICE 7575 METROPOLITAN DRIVE, SUITE 103 SAN DIEGO, CA 92108-4402 VOICE (619) 767-2370 FAX (619) 767-2384

Th5a 6-19-1013 (Caulfield et al. Revetment)

September 10, 2020

EXHIBITS

EXHIBIT 1: Project Location EHXIBIT 2: Site Plans

Page 2: SAN DIEGO DISTRICT OFFICE 7575 METROPOLITAN DRIVE, SUITE 103 SAN DIEGO… · 2020. 8. 21. · SAN DIEGO DISTRICT OFFICE 7575 METROPOLITAN DRIVE, SUITE 103 SAN DIEGO, CA 92108-4402

Project Location

Oceanside

Page 3: SAN DIEGO DISTRICT OFFICE 7575 METROPOLITAN DRIVE, SUITE 103 SAN DIEGO… · 2020. 8. 21. · SAN DIEGO DISTRICT OFFICE 7575 METROPOLITAN DRIVE, SUITE 103 SAN DIEGO, CA 92108-4402

0 �

1� -0

ti�

...

VICINITY MAP OF NORT!-IERN PROPERTY

1941 5. FACIFIC ST.

NOTE! REMOVE EXISTING STONE &: SORT INTO 'A' - STONE SIZES REUSE PER SPECIFiCATIONS. D.ISPOSE UNSUITABLE MATERIAL OFF'S!TE.

GROUND .SURFACE �

'A' STONE - 6000-8000 LBS. 2 LAYERS - THICKNESS 7' "

TOP OF ELEVATION -, + 16' MSLD (MIN.) "·

--._....----...

2

·a�·_/�

FILTER FABRIC

24' _____,,----+----2 LAYERS OF FACING CLASS STONE OVER 4• TO ft' SANO AND FABRIC PROTECTION.

i-.-5• EXTENSION IF NO GAAVEL LAYER

"f;( STONE 1 000-2000 LBS 1WO LAYERS ON SLOPE - THICKNESS 3.6'

DESIGN TOE ELEV. ONE LAYER ON BOTTOM - THICKNESS 1.6' -2 MSLD (MAX).

ALL SEAWALLS SHALL BE C.ONSTRUCTED TO THESE STANDARDS UNLESS OTHERWISE APPROVED BY A WAVE AC.TION STUDY APPROVED BY THE CITY ENGINEER.

CITY APPROVED DETAIL

+16

+12

+10

+5

0

-2

+15

+10 -

11::1

I

"'--.UFFER SAND AREA

30'-0"

0 LOOSE BOULDERS TO BEREFLACED IN EXISTING WALL

AFFROXIMATE BOTTOM OF SEAWALL

AFFROXIMATE TOF OF REVETMENT

N '

0 z

r

a) -

X LU

(/) C

ro �

a..

·-

(/)

PLAN VIEW @ 1941 S. PACIFIC ST.

l/8' = l'-0"

'A' STONE - 6000-8000 LBS. 2 LAYERS - rmcKNESS 7'

/ APPROXIMATE t:XlSTlNG .,,...----BEACH LEVEL

TOP OF ELEVATION +16' MSLD (MIN,)

GROUND SURFACE

- +12

- +10

+5

- 0

- -2

• T!-1I5 SEAWALL DETAIL 15 REFRESENTATIVE OFTl-IE EXISTING SEAWALLS

• REFAIR WORK ASSOCIATED WITl-l T!-1I5 FERMITWILL CONFORM TO T!-1I5 DETAIL WITl-l Tl-IEFOLLOWING EXCEFTIONS:

I. NO NEW ROCK WILL BE IMFORTED2. NO INCREASE IN I-IEIGI-IT WILL BE DONE3. NO IMFACT OF SAND ABOVE OR BELOW

WALL 4. NO ALTERATIONS OF Tl-IE FOUNDATION OR

FILTER FABRIC 51-lALL BE DONE5. NO REMOVAL OR REFLACEMENT OF

DISFLACED LOOSE ROCK TO EXCEED 10%OF Tl-IE WALL'S TOTAL NUMBER OF ROCKS

SECTION A-A SEAWALL SECTION S!-IOWING RELOCATED

BOULDERS OUT OF Tl-IE SAND BEAC!-1

- NO SCALE -

6-11-20

REPAIR .t MAINTENANCE PLAN OF

EXISTING SEAWALL (REVETMENT)

ADDRESS: 1941 5. FACIFIC ST. OCEANSIDE, CA

EXAMFLE: NORTI-IEF:N FROFERTY - WITHIN A GROUF FERMIT

Page 4: SAN DIEGO DISTRICT OFFICE 7575 METROPOLITAN DRIVE, SUITE 103 SAN DIEGO… · 2020. 8. 21. · SAN DIEGO DISTRICT OFFICE 7575 METROPOLITAN DRIVE, SUITE 103 SAN DIEGO, CA 92108-4402