sampling issues for optimization in radiotherapy

41
Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Upload: azia

Post on 04-Feb-2016

67 views

Category:

Documents


0 download

DESCRIPTION

Sampling Issues for Optimization in Radiotherapy. Michael C. Ferris R. Einarsson Z. Jiang D. Shepard. Conformal Radiotherapy. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Sampling Issues for Optimization in Radiotherapy

Sampling Issues for Optimization in Radiotherapy

Michael C. FerrisR. Einarsson

Z. JiangD. Shepard

Page 2: Sampling Issues for Optimization in Radiotherapy

Conformal Radiotherapy

• Enhanced conformation allows for greater dosages of radiation to reach the target volume (conformal shaping) while minimizing the dose delivery to surrounding normal tissues (conformal avoidance)

Page 3: Sampling Issues for Optimization in Radiotherapy

Beam’s eye view

• Beam’s eye view at a given angle is determined based upon the beam source that intersects the tumor

• The view is constructed using a multi-leaf collimator

Page 4: Sampling Issues for Optimization in Radiotherapy

Delivery Plan

plus some integrality constraints

Page 5: Sampling Issues for Optimization in Radiotherapy

Mixed Integer Approach

Page 6: Sampling Issues for Optimization in Radiotherapy

Dose/Volume Constraints

• e.g. (Langer) no more than 5% of region R can receive more than U Gy

Page 7: Sampling Issues for Optimization in Radiotherapy

Alternative approaches

• Conditional Variance at Risk (CVAR)• Convex form that approximates

DVH constraints• Can use piecewise linearization and

adaptive penalty parameters• Alternatively use standard LP• P/L approach used in this work

Page 8: Sampling Issues for Optimization in Radiotherapy

Wedges• A metallic wedge

filter can be attached in front of the collimator.

• It attenuates the intensity of radiation in a linear fashion from one side to other.

• Particularly useful for a curved patient surface

• 5 positions considered: Open, North, East, South, and West.

Page 9: Sampling Issues for Optimization in Radiotherapy

Mixed Integer Approach

Page 10: Sampling Issues for Optimization in Radiotherapy

Conformal Therapy• Conventional treatment• Beam’s eye view (collimator shaping)• Multiple angles (choose subset)• Wedges (modify intensity over field)• Non-coplanar beams (choose which planes)• Avoidance (upper bounds)• Homogeneity, conformality• Dose/volume constraints

Page 11: Sampling Issues for Optimization in Radiotherapy

Assumptions/Setting• Dose calculation via Monte Carlo• Objective is “truth”; we really do

want to minimize it• Limit discussion to beam angle

selection; ideas are perfectly generalizable

• Limit “planning tool” to 3DCRT via MIP because we are nearby Europe

Page 12: Sampling Issues for Optimization in Radiotherapy
Page 13: Sampling Issues for Optimization in Radiotherapy

Remarks

• CPLEX 9.0 used, tight tolerances• Branch/Bound/Cut code• LP relaxation solved using dual

simplex (small samples) and barrier method (large samples)

• Terma may add sparsity, CPLEX removes dense columns in factor

Page 14: Sampling Issues for Optimization in Radiotherapy

Problems

• Large computational times• Large variance in computing times

• 5000-12500 sec (for 60,000 voxel case)

• Ineffective restarts (what if trials?)• Large amounts of data

• Try sampling of voxels (carefully)

Page 15: Sampling Issues for Optimization in Radiotherapy

1% 3% 5% 7% 9% 11% 13% 15% 17% 19% 21%

0

200

400

600

800

1000

1200

1400

1600

Pelvis example: solution times for various sample rates;

Pro

cess

or

tim

e, [

sec]

Sampling rate

Page 16: Sampling Issues for Optimization in Radiotherapy

1% 3% 5% 7% 9% 11% 13% 15% 17% 19% 21%

1.5

1.6

1.7

1.8

1.9

2

2.1

2.2

Pelvis example: objective values for various sample rates;

Ful

l o

bje

ctiv

e v

alu

e

Rate

Page 17: Sampling Issues for Optimization in Radiotherapy

Naïve sampling fails• Normal tissue

• Many more voxels available• Streaking effects• Use 5x sample on 2nd largest structure

• Small structures• Minimum sample size

• Homogeneity/min/max on PTV• 2x sample on PTV, rind sampling

• Large gradients on OAR’s• 2x sample on OAR’s

• Need adaptive mechanism

Page 18: Sampling Issues for Optimization in Radiotherapy
Page 19: Sampling Issues for Optimization in Radiotherapy
Page 20: Sampling Issues for Optimization in Radiotherapy
Page 21: Sampling Issues for Optimization in Radiotherapy

Time/quality tradeoff• Not really satisfactory• Split up problem into two phases

• Find a reduced set of angles at coarse sampling

• Optimize with reduced set of angles with finer sample

• Reduced angle problem much faster

• But doesn’t identify angle set well…

Page 22: Sampling Issues for Optimization in Radiotherapy
Page 23: Sampling Issues for Optimization in Radiotherapy

Multiple samples

• Generate K instances at very coarse sampling rate

• Use histogram information to suggest promising angles

• How many? (e.g. K=10)• How to select promising angles?

(frequency > 20%)

Page 24: Sampling Issues for Optimization in Radiotherapy

Full Objective Value• >20% scheme may lose best solution• Can calculate the objective function

with complete sample cheaply from solution of sampled problem

• Use extra information in 2 ways:1. Select only those angles that appear in the

best “full value” solutions2. Refine samples in organs where

discrepancies are greatest

Page 25: Sampling Issues for Optimization in Radiotherapy

0.6 1.2 2.4 3.6 4.8 7.2 9.6 14.4 30 600

0.02

0.04

0.06

0.08

0.1

0.12

0.14

0.16

0.18

0.2

Sample size (*1000)

Error in objective components

Err

or

totptvblarecnor

Page 26: Sampling Issues for Optimization in Radiotherapy

Phase I• Must be very fast to be useful• LP relaxation much quicker

(allowing larger sample rates) and time variance much smaller

• But too many angles suggested…

• Utilize summed weight information to rank angles over complete set

Page 27: Sampling Issues for Optimization in Radiotherapy

Drawbacks• Weight values not necessarily

correlated to “usefulness”• Sample objective is underestimator,

and provides little information

• Utilize this procedure to do “gross reduction”, followed by Phase II to refine angles further

Page 28: Sampling Issues for Optimization in Radiotherapy

Sampling Process

• Determine initial sample size• Phase I: use all angles

• 10 sample LP’s solutions determine

• Phase II: use reduced set of angles• 10 sample MIP’s determine

• Phase III: use further reduced set • Increase sample rate, solve single MIP

Page 29: Sampling Issues for Optimization in Radiotherapy

Initial sample size• Choose trial sample size K• Solve LPrelax(K)• Double K until Time(LPrelax(2*K))

unacceptable• If

unacceptable, ERROR(more time) • Value(K) is full sample objective

value from sample size K optimization

Page 30: Sampling Issues for Optimization in Radiotherapy

Phase III

• Phase II may make all decisions so problem could be an LP for example

• Sample at fine enough rate to

satisfy industry requirements• Clean up phase!

Page 31: Sampling Issues for Optimization in Radiotherapy

Pelvis case

• 3K prostate, 1.5K bladder, 1K rectum, 557K normal

• Time for “full problem”: 12.5K secs• Time Phase I: 16 secs• Time Phase II: 100 secs• Time Phase III: 10 secs• Solution: 40, 80, 150, 240, 270, 300

Page 32: Sampling Issues for Optimization in Radiotherapy
Page 33: Sampling Issues for Optimization in Radiotherapy
Page 34: Sampling Issues for Optimization in Radiotherapy

Pancreas case

• 6K pancreas, 515 cord, 9K ltt, 6K rtt, 54K liver, 502K normal

• Time for “full problem”: 1200 secs• Time Phase I: 2 secs• Time Phase II: 12 secs• Time Phase III: 80 secs• Solution: 80, 290, 350 (+ wedges)

Page 35: Sampling Issues for Optimization in Radiotherapy
Page 36: Sampling Issues for Optimization in Radiotherapy

Breast case

• 39K ptv, 13K heart, 11K rind breast, 71K normal

• Time Phase I: 18 secs• Time Phase II: 11 secs• Time Phase III: 2 secs• Solution: 130, 290 (+ wedges)

Page 37: Sampling Issues for Optimization in Radiotherapy
Page 38: Sampling Issues for Optimization in Radiotherapy
Page 39: Sampling Issues for Optimization in Radiotherapy

Head/Neck case

• 2K ptv, 51K l/rcerebrum, 2K brainstm, 14K cerebellum, others (15-833)

• Time for “full problem”: 2542K secs• Time Phase I: 10 secs• Time Phase II: 22 secs• Time Phase III: 2 secs• Solution: 30, 140, 230 (+ wedges)

Page 40: Sampling Issues for Optimization in Radiotherapy
Page 41: Sampling Issues for Optimization in Radiotherapy

Extensions

• Within 3DCRT• Wedges, energy levels, non-coplanar

beams all optimized concurrently

• Tomotherapy• IMAT• IMRT• Larger and more complex cases