Report: 2710688-06 R1 Project: 2710688 Client: KMW Inc. 6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134 Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948 www.csagroup.com Page 1 of 16 PHOTOMETRIC TESTING & EVALUATION TO IES LM-79-08 Sample Tested MT150-A3S50 Prepared for: Janie Chung KMW, Inc. 183-6 Yeongcheon-ri, Dongtan-myeon, Hwaseong-si, Gyeonggi-do Korea 445-813 Phone: (206) 422-8373 Technical Report Number 2710688-06 R1 March 21, 2014 Prepared by: Approved by: James E. Berkeley, Program Manager Jesse Whalen, Product Group Manager

Upload: others

Post on 18-Dec-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Report: 2710688-06 R1

Project: 2710688

Client: KMW Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 1 of 16

PHOTOMETRIC TESTING & EVALUATION TO IES LM-79-08

Sample Tested

MT150-A3S50

Prepared for:

Janie Chung

KMW, Inc.

183-6 Yeongcheon-ri, Dongtan-myeon,

Hwaseong-si, Gyeonggi-do

Korea 445-813

Phone: (206) 422-8373

Technical Report Number

2710688-06 R1

March 21, 2014

Prepared by: Approved by:

James E. Berkeley, Program Manager Jesse Whalen, Product Group Manager

Report: 2710688-06 R1

Project: 2710688

Client: KMW Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 2 of 16

Program Description

Photometric and electrical testing of a “MT150-A3S50” Roadway Style Luminaire to IES LM-79-08.

Executive Summary

Sample Tested = MT150-A3S50

Luminous Efficacy*

(Lumens/Watt)

Luminous Flux*

(Lumens)

Input Power*

(Watts) Power Factor*

131.39 19910 151.53 0.9965

CCT (K)* CRI* Stabilization Time

(Light & Power)

4895.4 83.7 75 minutes

* The above results are recorded / derived from measurements made using an Integrating Sphere

Roadway Summary‡ - Utilization

Downward Utilization Percentage of Luminaire

Street Side Lumens 12,791.40 64.40%

House Side Lumens 7,065.40 35.60%

Total 19,856.80 100%

Upward Utilization 0 Lumens / 0.0% (No Up Light)

IES Classification Type – FullCutoff, Type III, Short ‡ Based upon IES file generated output – Total Lumens may differ from Integrating Sphere results.

Gonio-Photometric calculations based upon a mount height of 30ft.

Report: 2710688-06 R1

Project: 2710688

Client: KMW Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 3 of 16

TABLE OF CONTENTS

Sample..................................................................................................................................................................... 4

Test Results ............................................................................................................................................................. 5

Spectral Flux ........................................................................................................................................................... 6

Chromaticity Diagram ............................................................................................................................................ 7

Flux Distribution – Zonal Lumen Summary ........................................................................................................... 8

Illuminance Plots .................................................................................................................................................... 9

Candela Plots ........................................................................................................................................................ 10

Candela Tabulation ............................................................................................................................................... 11

In Situ Temperature Measurement: ...................................................................................................................... 12

BUG Rating Analysis ........................................................................................................................................... 13

Photometric Testing Information .......................................................................................................................... 14

Equipment List: ..................................................................................................................................................... 16

Report: 2710688-06 R1

Project: 2710688

Client: KMW Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 4 of 16

Sample

The following sample was submitted for evaluation:

KMW Inc.: MT150-A3S50

MT150-A3S50 ROADWAY (STREET LAMP)

Report: 2710688-06 R1

Project: 2710688

Client: KMW Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 5 of 16

Test Results –

The following results were measured after stabilization of the sample in the Integrating Sphere (unless

otherwise stated). Stability is reached when the variation of 3 readings of light output and electrical power,

taken 15 minutes apart, is less than 0.50% (in accordance with IES LM-79-08).

Key Photometric Results Sample Reference

MT150-A3S50 ROADWAY STREET LAMP Integrating Sphere Goniophotometer

Luminous Efficacy (Lumens/Watt) 131.39 131.05

Total Luminous Flux (Lumens) 19910 19857.32

Total Radiant Flux (Watts) 64.65

Correlated Color Temperature (CCT) 4895.4

Color Rendering Index (CRI) (Ra) 83.7

R1 thru R7 Value 81.5 87.6 92 83.6 82.1 82.6 89

R8 thru R14 Value 71.2 16.4 70.4 82.3 61.9 82.8 95.7

Chromaticity (Chroma x / Chroma y) 0.3485 / 0.3583

Chromaticity (Chroma u / Chroma v) 0.2111 / 0.3256

Chromaticity (Chroma u’ / Chroma v’) 0.2111 / 0.4884

Duv Value 0.00201

Stabilization Time (Light and Power) Approx. 75 minutes

Total Run Time – Integrating Sphere 79 minutes

Total Run Time – Goniophotometer 74 minutes

IES Classification FullCutoff Type III – Short

Scotopic/Photopic ratio Φ(v')/Φ(v) 1.925

Electrical Input Results: Sample Reference

MT150-A3S50 ROADWAY STREET LAMP Input Power (Watts) 151.53 (146.42)

Input Voltage (Volts AC) 120.00 (277.05)

Input Current (Amps) 1.2672 (0.5539)

Input Frequency (Hertz) 60.0

Power Factor 0.9965 (0.9541)

Total Harmonic Distortion (%THD V/A) 0.10 / 4.52 (0.11 / 12.86)

Additional Information Sample Reference

MT150-A3S50 ROADWAY STREET LAMP Ambient Temperature 24.1 °C

Integrating Sphere Detector CDS 600 Spectroradiometer

Absorption Correction used? Yes

Report: 2710688-06 R1

Project: 2710688

Client: KMW Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 6 of 16

Spectral Flux

The following graph shows the spectral response curve of the radiant flux for the sample:

Spectral response of the Radiant Flux

(350nm to 850nm – calibrated range of the Spectroradiometer).

Report: 2710688-06 R1

Project: 2710688

Client: KMW Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 7 of 16

Chromaticity Diagram

The following image shows the chromaticity diagram for the sample:

Tristimulus values (from page 5):

x / y = 0.3485 / 0.3583

The locations on the diagram of the tristimulus coordinates are indicated by the blue diamond.

Report: 2710688-06 R1

Project: 2710688

Client: KMW Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 8 of 16

Test Results – Flux Distribution – Zonal Lumen Summary

The following table depicts the zonal lumen distribution for the sample:

Zone Lumens % Total 0 - 10 392.9 2.00%

10 - 20 1,180.30 5.90%

20 - 30 2,042.40 10.30%

30 - 40 2,815.20 14.20%

40 - 50 3,435.00 17.30%

50 - 60 4,052.20 20.40%

60 - 70 3,701.30 18.60%

70 - 80 2,024.50 10.20%

80 - 90 213.4 1.10%

Total 19857.3 Lumens 100%

Zonal Lumen Summary

Zone Lumens % Lamp / Luminaire 0-30 3,615.70 18.20%

0-40 6,430.90 32.40%

0-60 13,918.10 70.10%

60-90 5,939.20 29.90%

0-90 19,857.3 100%

Report: 2710688-06 R1

Project: 2710688

Client: KMW Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 9 of 16

Test Results – Illuminance Plots

The following images depict the illuminance characteristics of the luminaire.

Beam Angle Field Angle

Illuminance Plot (Footcandles) Roadway Utilization Curve

Report: 2710688-06 R1

Project: 2710688

Client: KMW Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 10 of 16

Test Results – Candela Plots

The following images depict the luminous intensity distribution characteristics of the luminaire.

Isocandela Plot Polar Candela Distribution

Report: 2710688-06 R1

Project: 2710688

Client: KMW Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 11 of 16

Test Results – Candela Tabulation

The following table provides the tabulated Candela measurements: Candela Table - Type C

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360

0 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153 4153

2.5 4266 4236 4250 4244 4269 4217 4162 4127 4150 4128 4081 4049 4027 4021 3990 3988 3961 3956 4056 4072 4095 4089 4067 4051 4064 4096 4153 4161 4147 4158 4137 4160 4170 4192 4238 4233 4266

5 4357 4363 4351 4339 4315 4270 4252 4211 4115 4135 4039 4036 4001 3938 3908 3872 3858 3845 3882 3889 3916 3930 3959 3982 4034 4023 4097 4144 4142 4209 4254 4235 4274 4258 4318 4288 4357

7.5 4456 4454 4465 4435 4359 4357 4266 4309 4207 4200 4107 4043 3960 3856 3843 3731 3690 3661 3723 3766 3767 3800 3867 3937 3974 4046 4084 4137 4193 4262 4285 4362 4356 4349 4362 4385 4456

10 4484 4462 4501 4487 4558 4588 4562 4452 4385 4314 4152 3993 3865 3780 3656 3577 3528 3480 3519 3526 3638 3727 3759 3831 3970 4034 4110 4206 4270 4279 4368 4399 4480 4441 4414 4490 4484

12.5 4509 4510 4589 4734 4861 4775 4702 4618 4485 4325 4161 3975 3783 3646 3504 3333 3273 3230 3315 3337 3397 3512 3599 3757 3874 3996 4157 4323 4469 4545 4582 4603 4553 4502 4493 4510 4509

15 4564 4617 4751 5032 5013 5053 4970 4816 4658 4457 4135 3835 3599 3472 3339 3224 3060 2965 3072 3098 3177 3308 3497 3600 3778 4003 4183 4348 4545 4704 4821 4920 4811 4669 4536 4482 4564

17.5 4533 4769 5012 5257 5224 5218 5172 5120 4967 4691 4300 3858 3463 3288 3170 3081 2826 2730 2809 2850 2994 3168 3298 3456 3615 3886 4196 4499 4715 4943 5006 5035 5079 4905 4617 4487 4533

20 4568 4911 5213 5370 5471 5528 5553 5453 5198 4949 4474 3900 3477 3136 2989 2859 2772 2559 2611 2664 2827 3042 3156 3277 3505 3935 4443 4786 5058 5216 5314 5302 5290 5085 4786 4554 4568

22.5 4690 5043 5398 5582 5754 5858 5844 5899 5429 5245 4619 4001 3438 3083 2773 2640 2524 2380 2410 2477 2711 2805 2966 3182 3522 4020 4573 5082 5385 5550 5606 5584 5534 5252 5022 4684 4690

25 4862 5182 5573 5844 5878 5941 6002 6105 5659 5446 4796 4134 3428 2968 2615 2426 2304 2106 2226 2314 2500 2610 2792 3104 3529 4118 4771 5418 5816 5879 5915 5893 5735 5478 5229 4827 4862

27.5 5111 5381 5784 5846 5905 6008 6112 6157 5890 5574 4957 4214 3470 2823 2494 2125 1956 1845 1964 1973 2206 2342 2658 2986 3589 4375 5038 5742 6149 6169 5990 6009 5929 5774 5444 5042 5111

30 5392 5599 5825 5836 5946 6064 6206 6250 6052 5656 5062 4200 3495 2793 2331 1907 1700 1624 1727 1674 1863 2078 2524 2887 3651 4457 5278 5863 6230 6242 6191 6025 5940 5894 5624 5313 5392

32.5 5654 5784 5810 5872 5983 6114 6256 6335 6197 5790 5169 4193 3574 2671 2119 1634 1528 1501 1584 1543 1688 1897 2355 2948 3647 4445 5297 5878 6282 6306 6240 6071 5920 5907 5802 5591 5654

35 5841 5818 5778 5834 5964 6081 6259 6406 6343 5942 5231 4270 3480 2606 1951 1487 1385 1362 1474 1423 1459 1695 2195 2841 3731 4524 5395 6008 6399 6398 6306 6120 5903 5944 5841 5866 5841

37.5 5976 5775 5697 5721 5896 6104 6378 6533 6491 6013 5307 4342 3402 2535 1834 1415 1181 1262 1345 1326 1279 1531 2050 2797 3789 4580 5530 6161 6535 6465 6280 6084 5928 5871 5829 6008 5976

40 5888 5638 5566 5612 5765 6136 6516 6670 6575 6129 5433 4408 3539 2422 1730 1360 1091 1134 1259 1175 1172 1467 1923 2767 3707 4640 5622 6274 6655 6584 6362 6067 5852 5797 5691 5910 5888

42.5 5583 5390 5424 5517 5822 6226 6626 6790 6636 6192 5498 4461 3551 2412 1697 1409 1066 1049 1215 1060 1121 1454 1851 2694 3838 4732 5738 6391 6721 6748 6470 5988 5695 5688 5492 5665 5583

45 5104 5048 5217 5502 5760 6284 6832 6942 6782 6224 5622 4561 3612 2386 1663 1339 1056 1042 1106 1047 1094 1404 1821 2645 3869 4843 5880 6414 6752 6872 6554 6054 5683 5522 5266 5251 5104

47.5 4823 4844 5075 5387 5772 6339 7020 7149 6962 6343 5778 4625 3714 2551 1608 1286 1043 1030 1066 1054 1090 1388 1775 2764 3933 4931 5961 6466 6845 7000 6670 6010 5620 5398 5057 4961 4823

50 4614 4698 4928 5279 5668 6429 7244 7372 7095 6432 5789 4723 3851 2781 1698 1258 999 1003 1032 1046 1065 1362 1817 2942 4074 5075 5993 6591 7017 7238 6733 6033 5548 5229 4860 4739 4614

52.5 4444 4565 4711 5112 5646 6576 7480 7541 7246 6595 5777 4781 3867 3113 1936 1402 1013 979 989 1021 1045 1442 2003 3170 4205 5208 6048 6771 7210 7469 6896 6022 5508 5028 4737 4573 4444

55 4290 4385 4520 4947 5691 6812 7688 7711 7279 6736 5840 4960 3819 3103 2131 1544 1128 984 951 1027 1146 1624 2290 3383 4225 5314 6175 6934 7400 7688 7106 6107 5379 4841 4572 4411 4290

57.5 4115 4162 4326 4784 5822 6971 7636 7714 7184 6790 5814 5040 3668 2910 2131 1593 1175 985 919 1047 1243 1733 2436 3328 4141 5419 6236 7057 7530 7889 7348 6265 5331 4674 4379 4224 4115

60 3908 3939 4098 4683 5741 6654 7138 7080 6889 6668 5811 5022 3599 2685 1931 1484 1146 913 863 1020 1266 1729 2348 3194 4100 5476 6220 7101 7554 7861 7315 6449 5288 4462 4149 4021 3908

62.5 3650 3673 3841 4432 5326 5963 6516 6373 6146 6232 5518 4699 3498 2480 1732 1263 973 793 767 934 1142 1512 2189 2986 4055 5414 6178 6829 7085 7270 6929 6298 5227 4238 3895 3777 3650

65 3309 3332 3498 3936 4610 5144 5684 5560 5395 5623 5003 4421 3373 2311 1605 1164 885 676 640 806 1035 1377 1977 2817 4012 5206 5779 6269 6398 6530 6240 5781 4842 3949 3586 3467 3309

67.5 2858 2889 3038 3351 3850 4460 4871 4743 4556 4974 4449 3951 3080 2296 1544 1113 856 626 564 737 986 1289 1877 2708 3746 4723 5163 5457 5501 5604 5424 4951 4162 3525 3194 3084 2858

70 2367 2386 2497 2742 3330 3879 4158 4143 4023 4280 3850 3401 2780 2263 1595 1128 853 610 551 700 958 1235 1822 2646 3333 4023 4503 4662 4625 4754 4615 4212 3439 2957 2714 2594 2367

72.5 1858 1904 1995 2332 2912 3376 3624 3566 3416 3604 3242 2892 2313 1946 1419 1047 805 585 579 677 948 1222 1747 2364 2896 3366 3772 3951 3896 4048 3954 3638 2870 2428 2198 2098 1858

75 1385 1434 1511 1863 2281 2626 2775 2688 2580 2703 2532 2240 1805 1492 1045 737 557 416 527 584 796 1032 1467 1925 2375 2732 3126 3230 3311 3369 3390 3089 2485 1978 1704 1611 1385

77.5 922 942 1002 1206 1498 1724 1820 1781 1670 1689 1605 1472 1180 931 653 437 294 213 326 333 476 660 1051 1460 1839 2015 2380 2471 2518 2537 2568 2331 1868 1466 1205 1130 922

80 507 515 530 632 792 872 849 842 757 692 637 630 522 353 250 224 161 128 160 177 263 401 622 914 1101 1203 1498 1582 1623 1726 1701 1514 1176 894 729 671 507

82.5 182 173 181 200 229 182 178 184 148 132 120 124 133 129 101 100 93 82 98 111 143 179 213 341 449 524 588 700 726 809 795 719 566 410 337 305 182

85 35 34 34 37 36 36 31 29 32 33 34 32 38 72 81 78 75 59 62 84 87 87 95 102 104 277 108 142 155 179 147 149 114 103 80 73 35

87.5 9 14 8 9 9 10 10 12 13 14 14 12 11 12 15 13 11 9 18 32 47 63 63 38 23 30 23 22 24 22 27 28 27 20 18 18 9

90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Report: 2710688-06 R1

Project: 2710688

Client: KMW Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 12 of 16

Thermocouple Location Temperature Measured (°C)

LED Top of Row / Driver 66 / 61.9

LED Center 81

Ambient 50.0

TC Location on LED Top of Row TC Location on Driver

TC Location Center LED

In Situ Temperature Measurement:

Test Overview

The sample was tested in the CSA Atlanta, GA lighting laboratory at a regulated and controlled ambient

temperature of 50°C ± 1°C

Data was taken on a Fluke 54II calibrated to ISO 17025

The sample was powered continuously from a conditioned 120.0V AC Source (60 Hertz).

Temperature data was recorded after 7 hours of operation (stabilization).

Tc was monitored using a J-Type thermocouple on the manufacturers designated temperature

measurement location as shown in the photographs above:

Report: 2710688-06 R1

Project: 2710688

Client: KMW Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 13 of 16

BUG Rating Analysis

The following table shows the BUG rating classification:

Luminaire Classification System (LCS)

LCS Zone Lumens % of Luminaire FL 0 - 30 2184.5 11

FM 30 - 60 6887.4 34.7

FH 60 - 80 3590.1 18.1

FVH 80 - 90 129.4 0.7

BL 0 - 30 1430.8 7.2

BM 30 - 60 3414.5 17.2

BH 60 - 80 2137.1 10.8

BVH 80 - 90 84.1 0.4

UL 90 - 100 0 0

UH 100 - 180 0 0

Total 19857.9 100

BUG RATING = B3-U0-G3

Report: 2710688-06 R1

Project: 2710688

Client: KMW Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 14 of 16

Continued…..

Photometric Testing Information

The sample was evaluated for photometric and electrical characteristics using an integrating sphere and a

goniophotometer, each located in purpose-built, temperature and humidity-controlled, draft free environments.

The integrating sphere is by Labsphere which exhibits a “4π geometry” configuration according to IES LM-79-

08 and is applicable for all types of LED products (directional and non-directional light projections). Its

spectroradiometer is an array-type detector manufactured and calibrated by Labsphere.

The integrating sphere uses self-absorption correction to eliminate errors due to mismatches between the

standard reference lamp and the test samples being measured. The auxiliary lamp used to perform this task is a

halogen type lamp powered by a calibrated Lamp Power Supply manufactured and calibrated by Labsphere.

Ambient temperature (for photometric analysis) is measured using a “J-Type” thermocouple located inside the

integrating sphere at the same height as the sample under test and not more than 1 meter in horizontal distance

away from the sample. The thermocouple is located behind the baffle of the photo detector in order to eliminate

any direct optical radiation from the sample under test.

Luminaire Stabilization.

The sample was placed inside the integrating sphere and powered by a regulated and conditioned Voltage

alternating current supply. The correlated color temperature, color rendering index, chromaticity coordinates

and electrical power measurements contained in this report are the numeric averages of the three readings upon

which stabilization is verified. The stabilization times shown on the results pages of this report denote the time

of the 1st measurement (of the 3 consecutive readings) since this is the minimum time that the sample is

assumed to have taken to reach stabilization.

The integrating sphere is calibrated using a quartzline halogen lamp with the following specifications:

Manufacturer: Sylvania

Model# 75Q/CL-28V

Voltage = 28.0 Volt

Wattage = 75.0 Watts

Calibration Current = 2.679 Amperes

Luminous Flux = 1538.8 Lumens

Calibration Date = 8-18-2005 (calibrated by Labsphere – NIST traceable).

Report: 2710688-06 R1

Project: 2710688

Client: KMW Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 15 of 16

Photometric Testing Information (continued)

The goniophotometer Mayer Engineering Type C is calibrated using a frosted tungsten filament FDS/DZE lamp

with the following specifications:

Manufacturer: GE

Part Number: DZE 88

Bulb Number: 114-A

Voltage: 16.59 Volts DC reference

Calibration Current: 4.810 Amperes

Luminous Intensity: 154.7 Candelas

Calibration Date: 7/12/12 (NIST traceable)

Manufacturer: GE

Part Number: DZE 88

Bulb Number: 114-B

Voltage: 16.61 Volts DC reference

Calibration Current: 4.819 Amperes

Luminous Intensity: 150.6 Candelas

Calibration Date: 7/12/12(NIST traceable)

Manufacturer: GE

Part Number: DZE 88

Bulb Number: 114-C

Voltage: 16.66 Volts DC reference

Calibration Current: 4.815 Amperes

Luminous Intensity: 155.4 Candelas

Calibration Date: 7/12/12 (NIST traceable)

A Yokogawa WT210 Power Analyzer was used to measure all electrical characteristics of the sample.

CSA is an accredited Test Laboratory

National Voluntary Laboratory Accreditation Program

(NVLAP)200732-0

Report: 2710688-06 R1

Project: 2710688

Client: KMW Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 16 of 16

All equipment is calibrated to ISO / IEC 17025-2005 guidelines.

R1 – Additional ISTMT test adding thermocouple to a center LED on the junction.

Equipment List: Goniophotometer Type C (Mirror 1)

Description Manufacturer and

Model Number

CSA Instrument

Reference Number

Calibration Due

Date

Optometer Gigahertz Optik P9801 N/A N/A

Regulated Power Supply Chroma Instruments 61602P-

80-60 DCP401 N/A

Regulated Power Supply Chroma Instruments 61602 DCP301 N/A

Power Analyzer Yokogawa WT210 POA400 11/2014

Equipment List: Sphere C Equipment

Description Manufacturer and

Model Number

CSA Instrument

Reference Number

Calibration Due

Date

Integrating Sphere 76” Labsphere LMS760 SPH300 N/A

Spectroradiometer Labsphere CDS1100 CDS600C N/A

Auxiliary Lamp PSU Labsphere LPS100 LPS100 N/A

Power Analyzer Yokogawa WT210 PA118 12/2014

Regulated Power Supply Chroma Instruments 61603 AC302 N/A

Equipment List: In Situ Temperature

Thermometer

(Thermocouple) Fluke 54II TH109 8/2014

Environmental Chamber CSZ, ZPH-32-2-2-H/AC EC102 1/2015