salter-style demand cannulaold.salterlabs.com/documents/slc-10108.pdfof the inspiratory cycle,...

2
® Salter Labs O 2 XPRESS ® Oxygen Conserver Device A lightweight, all pneumatic oxygen demand conserver for CGA-870 post valve cylinders. Delivers a bolus of oxygen in the first one-third of the inspiratory cycle, resulting in O 2 saturations equal to or greater than a continuous flow treatment. Provides up to a 3:1 oxygen savings over a continuous flow device at equivalent flow rates. Salter-Style ® Demand Cannula The O 2 XPRESS uses a special cannula designed to give users all the comfort and convenience of a Salter-Style cannula. Unique dual tubing delivers oxygen on demand through one tube while inspiratory effort is sensed through the other tube. Features Rapid response to patient inspiratory effort Delivers bolus of oxygen in first one-third of inspiration Utilizes all Salter-Style Demand Cannulas All pneumatic operation Single knob operation, ten (10) pre-set flow settings Large, easy grip T-handle on yoke fitting Benefits Optimizes oxygenation Provides up to 3:1 oxygen savings vs. a continuous flow at equivalent settings with comparable or greater O 2 saturations Optimum performance with complete patient comfort No batteries to replace. No user maintenance required Simple to operate, easy to set up Easy for user to change cylinders Variety of uses...Hospital, Skilled Nursing Facility, Homecare, Clinic ® slc 101

Upload: others

Post on 16-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Salter-Style Demand Cannulaold.salterlabs.com/documents/SLC-10108.pdfof the inspiratory cycle, resulting in O2 saturations equal to or greater than a continuous flow treatment. Provides

®

Salter Labs

O2XPRESS®

Oxygen Conserver DeviceA lightweight, all pneumatic oxygen demand conserver for CGA-870 post valve cylinders. Delivers a bolus of oxygen in the first one-third of the inspiratory cycle, resulting in O2 saturations equal to or greater than a continuous flow treatment. Provides up to a 3:1 oxygen savings over a continuous flow device at equivalent flow rates.

Salter-Style® Demand CannulaThe O2XPRESS uses a special cannula designed to give users all the comfort and convenience of a Salter-Style cannula. Unique dual tubing delivers oxygen on demand through one tube while inspiratory effort issensed through the other tube.

Features■■ Rapid response to patient inspiratory effort

■■ Delivers bolus of oxygen in first one-third of inspiration

■■ Utilizes all Salter-Style Demand Cannulas

■■ All pneumatic operation

■■ Single knob operation, ten (10) pre-set flow settings

■■ Large, easy grip T-handle on yoke fitting

Benefits■■ Optimizes oxygenation

■■ Provides up to 3:1 oxygen savings vs. a continuous flow atequivalent settings with comparable or greater O2 saturations

■■ Optimum performance with complete patient comfort

■■ No batteries to replace. No user maintenance required

■■ Simple to operate, easy to set up

■■ Easy for user to change cylinders

Variety of uses...Hospital, Skilled Nursing Facility, Homecare, Clinic

®

slc 101

SLC-101 6/5/08 2:59 PM Page 1

Page 2: Salter-Style Demand Cannulaold.salterlabs.com/documents/SLC-10108.pdfof the inspiratory cycle, resulting in O2 saturations equal to or greater than a continuous flow treatment. Provides

Salter O2XPRESS® Model 8511*A rugged, compact, lightweight, dual port, bolus styleoxygen conserver. Precise delivery of 10 pre-set flowrates. Simple set up with two (2) barbed tubing fittings toconnect the comfortable Salter-Style® Demand Cannula.

Only one dial to adjust for patient flow delivery. Large“winged-T” allows convenient secure connection to anyCGA-870 post style oxygen cylinder. Regulator deliverspre-set bolus and flow rate during first one-third ofinspiratory cycle. Remains off during the exhalationphase to maximize cylinder contents. Patented rapidresponse regulator design provides exceptionalsensitivity to a patient’s breathing patterns. The SalterO2XPRESS Conserver comes complete with two of thepatented Salter-Style Demand Cannulas. TheO2XPRESSConserver is proven clinically equivalent tocontinuous flow at both rest and exercise.# It typicallyextends cylinder duration up to three times.

Ordering Information Units/cs Part# Int’l Part#

O2XPRESS with (2) two Adult Demand Cannulas, 8511 8512(includes #4807 with 7' tubing and #4804 with 4' tubing)

All of the above, plus Safe-T bag carrying case 8511B

Inlet Seal Washers (Viton rubber/brass, 5/bag) 10 or 25 1248

Adult Demand Cannula with 4' supply tube 10 or 25 4804

Adult Demand Cannula with 7' supply tube 10 or 25 4807

Small Adult/Pediatric Demand Cannula with 4' supply tube 10 or 25 4824

Small Adult/Pediatric Demand Cannula with 7' supply tube 10 or 25 4827

Salter Safe-T bag, durable polyester M6 or C cylinder bag. 8558Adjustable strap and swivel snap hooks for vertical or horizontal carrying. Mesh venting panel and clear contents gauge viewing window, black# Respiratory Care Oct.2001 page 1095 (OF-01-193) Printed in U.S.A U.S. Patent Nos. *5,666,945, 6,237,594, 6,425,396, 6,378,520, 6,318,366 **5,137,017 Other U.S. and worldwide patents pending © Copyright Feb., 2002, Revised July, 2008 Salter Labs® SLC-101

Color codedcontents gauge

“Winged-T” handle

Oxygen delivery portPatient sensor port

Settingindicator

Flow rateselector knob

O2XPRESS®

Demand Cannula

Salter Safe-T Bag

Salter Adult Demand Cannulas** #4804 #4807

Bag with multiple positionadjustable strap. Zipper designallows safe, secure cylinderpositioning. Clear contentsgauge window and a uniquepatient tubing port provideexceptional comfort andconvenience to the LTOT user.

SpecificationsSize: 3.5" L x 2.1" W x 5.0" H (8.9 cm x 5.3 cm x 12.7 cm)Weight: 1 lb./.45kgFlow Rate selections: 0, 1⁄2, 3⁄4,1, 11⁄2, 2, 21⁄2, 3, 4, 5, 6 LPMOxygen Supply Pressure: 200 - 3,000 PSI (1378.9-20,683.8 KPa)Oxygen Cylinder Connection: CGA - 870 Post ValveOperating Temperature: 0/45° C (32/113° F)Storage Temperature: -40/70° C (-40/158° F)

PermanentBarrier

Oxygen DeliveryPatient Sensing

Salter-Style Demand Cannula**The O

2XPRESS Conserver uses the special patented Salter-Style Demand

Cannula. The unique dual tubing design delivers oxygen on demandthrough one tube while inspiratory effort is sensed through the other tube.

100 W. Sycamore Road - Arvin, CA 93203Phone: 661-854-31661-800-421-0024 1-800-235-4203 Fax: 661-854-3850Toll Free Fax: 1-800-628-4690 E-mail: [email protected]

ISO 9001 & ISO 13485 0482

®

SLC-101 6/5/08 2:59 PM Page 2