SALES INFORMATION 1 CATCHPOLE PLACE, WOODEND Dwelling 2 living areas with open plan kitchen/dining and separate pantry, plus study nook, 3 bedrooms including master with walk-in wardrobe, 2 bathrooms including en-suite with underfloor heating and double car garage. The floor area is 210m2. Designed by DNA Architecture and built by Howard Construction Ltd. 10 Year Builders Guarantee. Currently being operated as a Sales Office for the Two Roads subdivision. Legal Description Lot 22 DP 500690, CT CB15F/286 with a land area of 628m2 Lease Flexible settlement terms are available with the ability for the Show Home to be rents back ($600 per week) on a short-term basis. Contact Please contact Kerry Watson on 021 341 363 or [email protected] for further information. SALE PRICE: $595,000 (incl GST)

Upload: others

Post on 04-Jun-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SALES INFORMATION 1 CATCHPOLE PLACE, WOODEND · 100x3.75 nails. refer to nzbc g12/as1 figure 14. hwc relief valve drain - copper pipe in accordance with nzbc g12/as1 6.7.2 7) provide

SALES INFORMATION 1 CATCHPOLE PLACE, WOODEND

Dwelling 2 living areas with open plan kitchen/dining and separate pantry, plus study nook, 3 bedrooms including master with

walk-in wardrobe, 2 bathrooms including en-suite with underfloor heating and double car garage. The floor area is

210m2.

Designed by DNA Architecture and built by Howard Construction Ltd.

10 Year Builders Guarantee.

Currently being operated as a Sales Office for the Two Roads subdivision.

Legal Description Lot 22 DP 500690, CT CB15F/286 with a land area of 628m2

Lease Flexible settlement terms are available with the ability for the Show Home to be rents back ($600 per week) on a

short-term basis.

Contact Please contact Kerry Watson on 021 341 363 or [email protected] for further information.

SALE PRICE: $595,000 (incl GST)

Page 2: SALES INFORMATION 1 CATCHPOLE PLACE, WOODEND · 100x3.75 nails. refer to nzbc g12/as1 figure 14. hwc relief valve drain - copper pipe in accordance with nzbc g12/as1 6.7.2 7) provide

ISSUE DATE: VERSION:29/03/16 0128/06/16 02

JOB TITLE:

GW HOUSESLIMITED

SHEET:

FLOOR PLAN

OF:

A2.1

24

SCALE:

JOB #

1619

1:100

DESIGNER:

VERSION:

CT

5

DATE OF ISSUE:

AMENDMENT DATE:

16/12/2014

29/03/2016

NOTES:- Subject to council approval- All measurements to be confirmed on site by the contractor prior to the commencement of work

© 2015 DNA Architectural LTD.All rights reserved. No part of this work covered by copyrightmay be reproduced or copied in any form or by any meanswithout the written permission of DNA Architectural LTD

LEGAL DESCRIPTION:

Lot: 22 DP: 33116Petries Road, Woodend

DRAWING TITLE:

SM

SM

SM

FLOOR AREA( (OVER FOUNDATION):210.70 m2

500 B

asin

D2

W1

D3760 760

D1910

D16

2/86

8

D15

810

W4

W7

W6

W5D1

181

0

D20

810

D172/1,063

D12

810

D19

2/1,

023

W3

D42/810

D5

2/810

D6

2/810

D21

810

D14

810

D18

810D1

3

810

D17

810

W2

D9900

D10

810

810

D8

710

710

wm

1,720

776

FFL + 7.575

S1

S1

S2 S2

S3

S3

5.04 m2

2.51 m2

6.87 m2

18.28 m2

2.03 m2

FLOOR AREA (OVER FRAME): 206.56 m2

90x45mm timber frame columns

4.8m

colou

rstee

l sec

tiona

l flat

pane

l gar

age d

oor

Covered Area(Flat soffit)

600x600 ceilingaccess panel

Allow to insulatebetween house and

garage

MDV

OutdoorHeatpump

Unit

TV

1675x760 NewburyIsland Bath

tr

(tiled)1m x 1.8m

trhwc

Tv(wall mounted)

GARAGE6.0 x 6.0m

LAUNDRY

LINEN

WC

BEDROOM 33.31 x 3.5m

BEDROOM 23.2 x 3.2m

BEDROOM 13.89 x 3.4m

WIR2.8 x 1.5m

ENSUITE2.8 x 1.8m

ROBE

PASSAGE1.0m wide

BATHROOM2.0 x 3.2m

PANTRY2.19 x 1.7m

KITCHEN4.0 x 3.0m

LIVING / DINING9.46 x 4.82m

LOUNGE4.75 x 4.7m

2/810

glaz

ed do

ors

ENTRANCE4.32 x 1.5m

ROBE

doublefridge High level

window withtiled sill

COVERED COURT

COVERED COURT

Skylight Above

concrete

carpet

carpet

carpet

carpet

carpet

carpet

carpet

dp dp

dpdp

dp

dp

gtORG

gt

AAV

dp

Wall

Mou

nted H

eatpu

mp

Covered Area(Flat soffit)

Covered Area(Flat soffit)

(2.7m Ceiling)

(2.7m Ceiling)

Beam above

Beam above

140x

45 B

eam

abov

e

ht

ht

(2.4m Ceiling)

MechanicalVent

meter boardMechanicalvent to dryer

SB

MechanicalVent from

Range

MechanicalVent

140x

45mm

stud

s @ 40

0crs

CLOA

KS C

UPBO

ARD

Cabin Hook

900 Basin

900 B

asin

W10 W8W9D7

910

5.07 m2

Allow to paint sealGarage Floor

as required by laundry

1m x 1m

(tiled)

STUDY NOOK

DW

FLOOR PLAN1:100

GENERAL CONSTRUCTION NOTES

ROOF:PURLINS: H1.2 70x45mm @ 900crs CENTRALLY & 600crs.TRUSSES: H1.2 TIMBER, AS PER MANUFACTURERS SPECIFICATIONS. REFER TOMANUFACTURERS TRUSS LAYOUT & PRODUCER STATEMENT.ROOF BRACING: AS PER TRUSS MANUFACTURERS DOCUMENTATION.FASCIA & RAINWATER SYSTEM: COLORSTEELDOWNPIPES: 75 x 50mm COLORSTEEL.SOFFITS: JAMES HARDIE 4.5mm SOFFIT LINING.

CEILING:CEILING BATTENS: 70 x 35mm H1.2 TIMBER @ 600crs.13mm STANDARD GIB TO CEILINGS.

WALL FRAMING:EXTERIOR WALL FRAMING: H1.2 90 x 45mm STUDS @ 600crs (2455m STUD), @400crs (2700m STUD), & DWANGS @ 800crsINTERNAL FRAMING: 90 x 45mm H1.2 STUDS @ 600crs, DWANGS @ 800crs.DWANGS AS LATERAL SUPPORT AS PER NZS 3604: 8.8.1THERMAKRAFT WATERGATE BUILDING PAPER10mm STANDARD GIB TO WALLS, EXCEPT WET AREAS10mm AQUALINE GIB TO WET AREAS

INSULATION:CEILINGS: BATTS R3.6EXTERIOR WALLS: BATTS R2.6 (& WALLS BETWEEN GARAGE AND HOUSE)TYVEK STRAPS STAPLED TO FRAMING, TO PREVENT INSULATION BULGING INTOCAVITY.

WHERE DOWNLIGHTS ARE TO BE INSTALLED, CA RATED DOWNLIGHTS WILL BESUPPLIED AND INSTALLED IN ACCORDANCE WITH NEW ELECTRICAL SAFETYREGULATIONS MAY 2012

LIGHTING AND ELECTRICAL BY OTHERS, ALL POSITIONS AND TYPES TO BESELECTED AND CONFIRMED BY CLIENT WITH CONTRACTOR

ALL INTERIOR DOORS TO BE PAINT FINISHED MDF HOLLOW CORE DOORS WITHSELECTED HARDWARE BY CLIENT

ALL WINDOW AND DOOR DIMENSIONS SHOWN ARE ROUGH OPENING, SITEVERIFY PRIOR TO FABRICATION

GIB AQUALINE TO ALL WET AREAS WITH 2 COATS OF ENAMEL PAINT FINISH TOUNTILED WALLS

ALL LINTELS MSG 8 UNLESS OTHERWISE STATED

ALL GLAZING TO COMPLY WITH NZS 4223

MECHANICAL EXTRACTION REQUIRED TO TERMINATE TO EXTERNAL AIR SPACE

HOT WATER PIPES TO BE SIZED ACCORDING TO NZBC G12 & NZS 4305:1996MAINS PRESSURE. \15mm DIA ALLOWS 12m MAX PIPE LENGTH. PIPE LENGTHBEYOND THIS MUST BE LAGGED

G E N E R A L N O T E S:

FLOOR AREA (OVER FOUNDATION): 210.70m2

FLOOR AREA (OVER FRAME): 206.56m2

TYPICAL CEILING HEIGHT: 2.4m (HEEL HEIGHT 260mm)RAISED CEILINGS: 2.7m (LIVING & ENTRANCE)INTERNAL DOOR HEIGHT: STANDARDINTERNAL DOOR WIDTH: STANDARDUNDERTILE HEATING TO AREAS: N/A

WALL CLADDING MATERIALS

- 50mm SUPERCRETE PANEL CLADDING SYSTEM ON TIMBER FRAMED WALL

ROOF CLADDING MATERIALSSELECTED COLORSTEEL ROOFLINE ROOFDEKROOF PITCH: 60 - 80 & 120

ALL MAIN ELECTRICAL APPLIANCES ARE SHOWN TO INDICATEWHERE POWER MUST BE PROVIDED. (REFRIDGERATOR,OVEN, COOKTOP, RANGEHOOD,INTERNAL HEATPUMP,EXTERNAL HEATPUMP, DRYER, WASHING MACHINE, WETAREA EXTRACT VENTS, METER BOX, SWITCH BOARD).ALL ELECTRICAL INSTALLATIONS TO BE IN ACCORDANCEWITH NZECP 51:2001ALL KITCHEN POWER POINTS, INCLUDING HOB, OVEN, WASTEDISPOSAL, RANGHOOD, REFRIGERATOR AND MICROWAVEARE TO HAVE ONE DOUBLE POWER POINT EACH, REFER TOKITCHEN DESIGN FOR LAYOUT AND POSITIONS OF KITCHENAREA SOCKETS ETC. ALL POWER POINTS ARE INDICATIVEONLY AND MUST BE POSITIONED AND CONFIRMED ON SITEBY ARCHITECT AND OR OWNER.WHERE DOWNLIGHTS ARE TO BE INSTALLED, ONLY CA 80, CA135, IC OR IC-F DOWNLIGHTS ARE PERMITTED IN PRIVATE ORRENTAL DWELLINGS. (NOTE THAT IC DOWNLIGHTS CAN ONLYBE USED WITH INSULATION THAT PASSES THE NEEDLEFLAME TEST OF AS/NZS 60598 2.2 CLAUSE 11.5). RECESSEDDOWNLIGHTS THAT ARE NOT LABELLED AS ABOVE ARE NOTPERMITTED TO BE INSTALLED INTO RESIDENTIAL BUILDINGS.TOTAL OF 20 LUX OF ILLUMINANCE FOR THE TOTAL WATTAGEREQUIRED PER M2 OF FLOOR AREA AS SHOWN IN NZBC G8 /AS1 TABLE 1. - LIGHTING AND ELECTRICAL BY OTHERS, ALLPOSITIONS AND TYPES TO BE SELECTED AND CONFIRMED BYCLIENT WITH CONTRACTOR.

GENERAL NOTES

THE PLANS ARE ISSUED SUBJECT TO THE FOLLOWINGNOTES:1) ALL BEAM SIZES SHOWN ARE TO BE CONFIRMED BYPRE-CUTTER MANUFACTURER AND SHALL COMPLYWITH NZS3604:20112) ALL CARPENTRY SHALL COMPLY WITH NZS 3604:20113) AND CURRENT AMENDMENTS.4) ALL PLUMBING AND DRAINAGE TO COMPLY WITHCURRENT APPROVED DOCUMENTS G1, G12, G13, AND G14.DOWNPIPES TO BE CONNECTED TO WATER TANK ORSTORMWATER DRAINAGE SYSTEM AS SOON AS PRACTICALAFTER ROOF IS LAID.5) SMOKE DETECTOR TO BE INSTALLED THROUGHOUT THEDWELLING TO COMPLY WITH NZBC F7/AS1SECT 3.1 TO 3.3.FITTED WITH HUSH FACILITY AS REQUIRED.ENSURE 300mm MIN FROM WALLS.6) 200 LTR HIGH PRESSURE HWC TO BE FITTED WITHTEMPORING VALVE AND SEISMIC RESTRAINTS: 3-25x1mmGALV STEEL STRAPS, TENSIONED WHEN FIXED IN PLACE.FIX WITH 8mm COACH SCREWS WITH 30x2mm WASHERS.INSTALL 50x50 VERTICAL BLOCKING FULL HEIGHT BOTHSIDES OF HWC, NAIL TO FRAMING @ 600 CRS MAX WITH100x3.75 NAILS. REFER TO NZBC G12/AS1 FIGURE 14. HWCRELIEF VALVE DRAIN - COPPER PIPE IN ACCORDANCEWITH NZBC G12/AS1 6.7.27) PROVIDE MECHANICAL VENTILATION TO BATHROOM ANDENSUITE WEISS FAN UNIT TO VENT OUT THROUGH SOFFIT.VENT DRYER TO OUTSIDE OF BUILDING (IF INSTALLED).8) ENSURE ALL WET AREAS, WALL AND FLOOR LININGSCOMPLY WITH NZBC E3/AS1 '3.0: WATERSPLASH' (SEMIGLOSS OR GLOSS PAINT FINISH OVER LININGS TO WALLS &CEILINGS, 150mm MIN. IMPERVIOUS LINING UPSTAND.9) CORROSION ZONE 'C': STEEL FIXINGS AND FASTENINGSTO COMPLY WITH NZS 3604:2011 TABLE 4.1. NAILS TOCOMPLY WITH NZS 3604:2011 TABLE 4.3.11) ALL EXPOSED STRUCTURAL STEELWORK (IFAPPLICABLE) TO BE HOT DIP GALVANISED.12) ALL DOWNLIGHTS TO BE CA RATED.(CA 80 ORCA135)13) ALL INTERNAL DOORS TO BE STANDARD HEIGHT.

SLIP RESISTANCELEVEL ACCESS ROUTES INCLUDING WALKING SURFACES SUCH ASDECKS, PATIOS AND STEPS ON THE APPROACH TO THE MAIN ENTRANCEOF HOUSING AND LEVEL ACCESSIBLE ROUTES SHALL HAVE A MEANCOEFFICIENT OF FRICTION (U), OF NOT LESS THAN 0.4 WHEN TESTED INACCORDANCE WITH AS/NZS 3661.1. FOR OTHER ACCESS ROUTES ACOEFFICIENT OF FRICTION OF LESS THAN 0.4 MAY BE ACCEPTABLE, BUTACCOUNT SHOULD BE TAKEN OF THE EFFECTIVENESS OF THESURFACE WHEN WET. FOOT PATHS TO COMPLY WITH ANTISLIPREQUIREMENTS OF NZBCD1/AS1 TABLE 2. EXTERNAL STEPS ANDPORCHES TO BE BROOMED FINISH CONCRETE.

LOCAL AUTHORITY APPROVED SMOKEALARMS WITH HUSH FACILITY

SELECTED GULLY TRAP. INSTALL INACCORDANCE WITH NZBC G13/ AS2CLAUSE 3.3GULLY TRAPS Ɩ 100mm MIN ABOVE FGL

SELECTED COLORSTEEL 75x50mm (MIN)RECTANGLE DP

GT

DP

N

Page 3: SALES INFORMATION 1 CATCHPOLE PLACE, WOODEND · 100x3.75 nails. refer to nzbc g12/as1 figure 14. hwc relief valve drain - copper pipe in accordance with nzbc g12/as1 6.7.2 7) provide

ISSUE DATE: VERSION:29/03/16 0128/06/16 02

JOB TITLE:

GW HOUSESLIMITED

SHEET:

ELEVATIONS

OF:

A3.1

24

SCALE:

JOB #

1619

1:100

DESIGNER:

VERSION:

CT

5

DATE OF ISSUE:

AMENDMENT DATE:

16/12/2014

29/03/2016

NOTES:- Subject to council approval- All measurements to be confirmed on site by the contractor prior to the commencement of work

© 2015 DNA Architectural LTD.All rights reserved. No part of this work covered by copyrightmay be reproduced or copied in any form or by any meanswithout the written permission of DNA Architectural LTD

LEGAL DESCRIPTION:

Lot: 22 DP: 33116Petries Road, Woodend

DRAWING TITLE:

4,464

W10

W8 W9

D7

FFL FFL

Build

ing he

ight

Powdercoated aluminium exterior joinery

SG

Skylight

SG SG

ObsObs

TV

Meterboard

CJ CJ

50mm Supercrete Panel Claddingsystem over 24mm cavity

Selected trapezoidal roofing on selfsupporting underlay on 75x45 H1.2 purlins @900crs max on approved nail plate trusses

CJ

4,464

D1

D2

W1 W2

FFL FFL

2.5m

heigh

t from

boun

dary

26 0 Recession Plane

Build

ing he

ight

Selected Colorsteel flat panel sectional garage door

Solid core front door in PC aluminium frame

Powdercoated aluminium exterior joinery

SG

TV

50mm Supercrete Panel Cladding systemover 24mm cavity

Selected trapezoidal roofing on self supporting underlay on 75x45H1.2 purlins @ 900crs max on approved nail plate trusses

CJ

60 Roof120 Roof

4,464

W3 W4 W7

W6

W5

FFL FFL2.5m

heigh

t from

boun

dary

260 Recession Plane

Build

ing he

ight

50mm Supercrete Panel Claddingsystem over 24mm cavity

Selected trapezoidal roofing on self supporting underlayon 75x45 H1.2 purlins @ 900crs max on approved nailplate trusses

Powdercoated aluminium exterior joinery

SG Obs

CJ

TV120 Roof 60 Roof

4,464

D3

D4

D6

D5

FFL FFL

Build

ing he

ight

Powdercoated aluminium exterior joinery

SG SGSGSG

SG

SG SG SG SG

CJ CJ

50mm Supercrete Panel Claddingsystem over 24mm cavity

Selected trapezoidal roofing on self supporting underlayon 75x45 H1.2 purlins @ 900crs max on approved nailplate trusses

SG

BUILDING ENVELOPE RISK MATRIXSouth Elevation

Risk Factor Risk Severity Risk ScoreWind zone (per NZS 3604) High risk 1Number of storeys Low risk 0Roof/wall intersection design Very high risk 5Eaves width Very high risk 5Envelope complexity Medium risk 1Deck design Low risk 0Total Risk Score: 12

BUILDING ENVELOPE RISK MATRIXWest Elevation

Risk Factor Risk Severity Risk ScoreWind zone (per NZS 3604) High risk 1Number of storeys Low risk 0Roof/wall intersection design Very high risk 5Eaves width Very high risk 5Envelope complexity Medium risk 1Deck design Low risk 0Total Risk Score: 12

BUILDING ENVELOPE RISK MATRIXEast Elevation

Risk Factor Risk Severity Risk ScoreWind zone (per NZS 3604) High risk 1Number of storeys Low risk 0Roof/wall intersection design Very high risk 5Eaves width Very high risk 5Envelope complexity Medium risk 1Deck design Low risk 0Total Risk Score: 12

BUILDING ENVELOPE RISK MATRIXNorth Elevation

Risk Factor Risk Severity Risk ScoreWind zone (per NZS 3604) High risk 1Number of storeys Low risk 0Roof/wall intersection design Very high risk 5Eaves width Very high risk 5Envelope complexity Medium risk 1Deck design Low risk 0Total Risk Score: 12

SOUTH ELEVATION1:100

WEST ELEVATION1:100

EAST ELEVATION1:100

NORTH ELEVATION1:100

Page 4: SALES INFORMATION 1 CATCHPOLE PLACE, WOODEND · 100x3.75 nails. refer to nzbc g12/as1 figure 14. hwc relief valve drain - copper pipe in accordance with nzbc g12/as1 6.7.2 7) provide

RECORD OF TITLEDERIVED FROM LAND INFORMATION NEW ZEALAND

FREEHOLD

Quickmap Title DetailsInformation last updated as at 29-Sep-2019

Identifier 745464Land Registration District CanterburyDate Issued 29 September 2016

Prior ReferencesCB15F/286

Type Fee SimpleArea 628 square metres more or lessLegal Description Lot 22 Deposited Plan 500690

Registered OwnersGW Woodend Limited

Subject to a right to convey electricity (in gross) over part marked A on DP 500690 in favour of MainPower New ZealandLimited created by Easement Instrument 10492281.2 - 29.9.2016 at 1:48 pm The easements created by Easement Instrument 10492281.2 are subject to Section 243 (a) Resource Management Act 1991 Land Covenant in Easement Instrument 10492281.3 - 29.9.2016 at 1:48 pm

The information provided on this report forms a guideline only. As a result, Custom Software Limited cannot and does not provide any warranties or assurances of any kind in relation to the accuracy of the information provided through this report, the Site and Service. Custom Software Limited will not be liable for any claims in relation to the content of this report, the site and this service.

Page 1 of 1Quickmap Title Details

7/10/2019file:///C:/Users/User/AppData/Local/Temp/QM_DocOrder.html

Page 5: SALES INFORMATION 1 CATCHPOLE PLACE, WOODEND · 100x3.75 nails. refer to nzbc g12/as1 figure 14. hwc relief valve drain - copper pipe in accordance with nzbc g12/as1 6.7.2 7) provide

SALES INFORMATION 1 CATCHPOLE PLACE, WOODEND

Dwelling 2 living areas with open plan kitchen/dining and separate pantry, plus study nook, 3 bedrooms including master with

walk-in wardrobe, 2 bathrooms including en-suite with underfloor heating and double car garage. The floor area is

210m2.

Designed by DNA Architecture and built by Howard Construction Ltd.

10 Year Builders Guarantee.

Currently being operated as a Sales Office for the Two Roads subdivision.

Legal Description Lot 22 DP 500690, CT CB15F/286 with a land area of 628m2

Lease Flexible settlement terms are available with the ability for the Show Home to be rents back ($600 per week) on a

short-term basis.

Contact Please contact Kerry Watson on 021 421 6824 or [email protected] for further information.

SALE PRICE: $595,000 (incl GST)